62'-0"
PZ3
PZ3
PZ3
PZ3
ENTIRE INSTALLATIONTREATED AS PZ2
2'-0" 2'-0" 2'-0"2'-0"1'-4"1'-4"1'-4"
4'-0" 4'-0"
DN
3/1
2D
N 3
/12
RIDGE
EAVEG
AB
LE
# 381 1STORY SFMANUFACUTRED HOME
ASP SHINGLE ROOF SLOPE 3/12
EXISTING ROOF TRUSSES SAME ON SOUTH SIDE BUT NOT SHOWN HERE (TYP)
CENTER EACH RAIL ONEXISTING ROOF TRUSS (TYP) SEE NOTES!
RAILS MOUNTED THRU 1" GALV FLOOR FLANGEATTACHED INTO TRUSSES AT EACH PANEL POINTSEE NOTES!
2'-0" 2'-0"
12
'-4
"
GSAS MODULE CLAMP ATEACH CROSSING POINT
SOLAR MODULE
CHANNEL NUT
SS.FENDER WASHER 1-1/2"
SS. CLAMP
UNISTRUT CHANNEL
UNISTRUT CHANNEL
MODULE MODULE
SS. CLAMP
MODULEMODULE
UNISTRUT
EXISTING RAFTER
EXIST. SHEETINGAND MEMBRANE
SS EMBED 1.5” MIN INTO RAFTER.USE FULL-DEPTH PILOT HOLE
FLANGEFILL W/ POLYURETHAN
SEALANT
V.I
.F.
PV MODULE
V.I
.F.
SHEET NO:
PUBLISHED:
SHEET NAME:
DRAWN: CHECKED:SB AG
EN
LAR
GE
D V
IEW
ING
& H
YP
ER
LIN
KS
:P
RIN
T V
ER
SIO
N O
F T
HIS
PLA
N P
RO
VID
ES
MIN
IMU
M I
NF
OR
MA
TIO
N N
EE
DE
D B
Y U
SE
RS
.
ELE
CT
RO
NIC
VE
RS
ION
(E
V)
PR
OV
IDE
S M
AG
NIF
IED
VIE
WIN
G U
P T
O 6
40
0%
. E
V A
LSO
PR
OV
IDE
S H
YP
ER
LIN
KA
CC
ES
S T
O O
EM
MA
NU
ALS
AN
D A
BU
ND
AN
T O
TH
ER
SU
PP
LEM
EN
TA
RY
IN
FO
RM
AT
ION
.EV
MA
Y B
E
AC
CE
SS
ED
AT
: W
WW
.GE
ZE
LMA
NP
E.C
OM
/PV
/0
19
6P
.NE
S_
YO
_P
lan
tati
on
_F
L.d
wg
REVISIONS:
01SCALE: N.T.S. IMAGERY MAY NOT CORRECTLY INDICATE CURRENT POTENTIAL SHADING OF PROPERTY.
PARCEL - (AHJ PROPERTY APPRAISER)02
SCALE: N.T.S.
AERIAL VIEW OF PROPERTY
I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATICDRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.
05SCALE: VARIES
EXISTING TYP ROOF TRUSS, DISPLAYED FOR INFORMATION. NOT DESIGNED BY THIS ENGINEER!
CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!
C
OP
Y R
IGH
T &
IN
TE
LLE
CT
UA
L P
RO
PE
RT
Y N
OT
ICE
•T
HIS
PLA
N S
ET
IS
CO
PY
RIG
HT
PR
OT
EC
TE
D A
ND
CO
NT
AIN
S I
NT
ELL
EC
TU
AL
PR
OP
ER
TY
WH
ICH
BE
LON
GS
TO
ALL
EN
GE
ZE
LMA
N P
E.
•A
CC
ES
S I
S G
IVE
N T
O T
HE
IN
FO
RM
AT
ION
HE
RE
ON
SO
LELY
FO
R T
HE
PU
RP
OS
E O
F C
OM
PLE
TIO
N O
F T
HE
PR
OJE
CT
FO
R W
HIC
H I
T I
S I
NT
EN
DE
D.
•N
O O
TH
ER
US
E M
AY
BE
MA
DE
OF
TH
E I
NF
OR
MA
TIO
N,
DR
AW
ING
S,
OR
ID
EA
S H
ER
EO
N W
ITH
OU
T T
HE
EX
PR
ES
S,
WR
ITT
EN,
PE
RM
ISS
ION
OF
ALL
EN
GE
ZE
LMA
N P
E
ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC
C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC
C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF
OWNER:
381 NW 135 AVE, PLANTATION, FL 33325
YU, KATE THIS PLAN IS ONLINE FOR REVIEW @
WWW.GEZELMANPE.COM/PV/0196P.NES_YU_PLANTATION_FL.PDF
CO
NT
AC
T D
ES
IGN
TE
AM
@
ww
w.G
eze
lma
nP
E.c
om
ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549
PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM
www.GezelmanPE.com
I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE FBC2007
W/09 SUPP. AND NATIONALELECTRICAL CODE.
CO
DE
VE
RIF
Y
06SCALE: 3/16 = 1'-0"
ROOF LAYOUT PLAN - 24 OR LESS PANELS
PHOTO-VOLTAIC (PV) SYSTEM STRUCTURAL INSTALLATION NOTES - ELECTRICAL DESIGN BY OTHERS:
THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY USERS (AHJ-AUTHORITY HAVING JURISDICTION AND INSTALLERS). USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC
VERSION) OF THIS PLAN THRU HYPERLINK ADDRESS PROVIDED ON THIS PLAN. ACTIVE HYPERLINKS EMBEDDEDIN EV PROVIDE SEAMLESS ACCESS TO VALUABLE SUPPLEMENTARY INFORMATION - SUCH AS OEM (ORIGINAL
EQUIPMENT MANUFACTURER/DISTRIBUTOR) INSTRUCTIONS. EV ALSO ALLOWS VIEWER TO STUDY THE PLANAND OEM DETAILS AT A MAGNIFICATION OF HIS CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN
A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. WIND IS THE ONLYLOAD OF SIGNIFICANCE FOR A ROOF-MOUNTED PV SYSTEM. PV MODULES (INCLUDING MOUNTING HARDWARE
& RACKING) IMPOSE A LOAD OF LESS THAN 4-PSF. THESE DRAWINGS AND ENGINEERING CONTAINED HEREINPROVIDE SITE SPECIFIC INSTALLATION DETAILS FOR A PV SYSTEM ON SUBJECT PROPERTY.
1. EACH PV MODULE SHALL ATTACH TO THREE UNISTRUT P1000T HOT GALVANIZED MOUNTING RAILS ATALL CROSSING POINTS WITH A GSAS MODULE CLAMP USING ¼-INCH STAINLESS STEEL BOLTS & CHANNELNUTS. ADJACENT MODULES SHARE CLAMPS.
2. UNISTRUT RAILS SHALL PARALLEL ROOF STRUCTURAL FRAMING DIRECTLY ABOVE TRUSSES AND BE
ATTACHED INTO TRUSSES AT EACH PANEL POINT CROSSED USING 5/16-DIAMETER STAINLESS STEEL LAGS
THRU 1-INCH GALVANIZED FLOOR FLANGES FILLED WITH NOA/PCA APPROVED POLYURETHANE ROOFSEALANT.
3. CONTRACTOR TO USE CARE TO HIT PANEL POINTS AT CENTERS. DRILL 3/16-INCH PILOT HOLES. FILL FLOORFLANGE WITH ROOF SEALANT TO SERVE AS PITCH POCKET, E.G. LAG THRU SEALANT FILLED, GALVANIZED,
1-INCH FLOOR FLANGE. LAGS SHALL PENETRATE TRUSS TOP CORD 1-1/2-INCHES MINIMUM.
4. CONTRACTOR SHALL ADHERE TO REQUIREMENTS OF CHAPTER 15 CURRENT FBC (FLORIDA BUILDINGCODE) AND BEST PRACTICES OF THE NRCA (NATIONAL ROOFING CONTRACTORS ASSOCIATION) ROOFING& WATERPROOFING MANUAL TO ENSURE THAT THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKSAT INITIAL INSTALLATION OR AS THE SYSTEM “AGES”.
5. CONTRACTORS, INSPECTORS, & PLAN REVIEWERS HAVING QUESTIONS, CONTACT EOR (ENGINEER OFRECORD) DIRECTLY - OFFICE: 813 909 1956, CELL: 813 650 7246
E-MAIL: [email protected]
WIN
DCONTRACTOR:
DOMINICK C. PORRETTO VP
A NATIONAL ELECTRIC SERVICE, INC.
3881 CRYSTAL LAKE DR. SUITE #4
POMPANO BEACH, FL 33064
PH. 954-448-1529
ANATIONALELECTRICSERVICE.COM
CVC 56852 - STATE LICENSED SOLAR
CONTRACTOR
03SCALE: NTS
PHOTO OF RESIDENCE - INSTALLATION SIDE
INSTALLATION LOCATION INSTALLATION LOCATION SOUTH SIDE
INS
TA
LLA
TIO
N O
F A
RO
OF
MO
UN
T
RE
NE
WA
BLE
EN
ER
GY
SY
ST
EM
TH
E Y
U H
OU
SE
38
1 N
W 1
35
AV
E,
PLA
NT
AT
ION
, F
L 3
33
25
SPEED: 140 MPH
EXPOSURE: C
IP CATEGORY: II
UPLIFT(PSF) : ENTIRE ROOF PZ2-55.8 PSF; PZ3- NOT ALLOWED
STRUCTURAL LOAD FROM EQUIP < 4PSF
ASCE PRESSURE ZONES: HTTP://UNIRAC.COM/PDF/II227.PDF
Jan. 8, 12
PV MODULE: CONTRACTOR CHOICE
DESIGNED PER: ASCE 7-05, 2010 NEC,FBC2007 W/09 SUPP.
AHJ: BROWARD COUNTY, FOLIO # 504002030600
INSTALLATION LOCATION
UNISTRUT TO PV PANEL CONNECTION W/ GSASSCALE: 3" = 1'-0"
GEZELMAN SOLAR ANCHOR SYSTEM (GSAS)
HTTP://GEZELMANPE.COM/REFERENCE/CLAMPPLATE.PDF
UNISTRUT P1000T HG (Hot Galvanized) FLANGE RAIL CONNECTION (TOP VIEW)FLANGE RAIL CONNECTION (CAMERA VIEW)GSAS MODULE CLAMP TO RAIL CONNECTIONTYP 1" GALV. FLOOR FLANGE W/ SEALANT
04SCALE: VARIES
RACKING - UNISTRUT WITH GSAS MODULE CLAMPS
RACKING TO TRUSS SECTIONSCALE: 3" = 1'-0"