62'-0" PZ3 PZ3 PZ3 PZ3 ENTIRE INSTALLATION TREATED AS PZ2 2'-0" 2'-0" 2'-0" 2'-0" 1'-4" 1'-4" 1'-4" 4'-0" 4'-0" DN 3/12 DN 3/12 RIDGE EAVE GABLE # 381 1STORY SF MANUFACUTRED HOME ASP SHINGLE ROOF SLOPE 3/12 EXISTING ROOF TRUSSES SAME ON SOUTH SIDE BUT NOT SHOWN HERE (TYP) CENTER EACH RAIL ON EXISTING ROOF TRUSS (TYP) SEE NOTES! RAILS MOUNTED THRU 1" GALV FLOOR FLANGE ATTACHED INTO TRUSSES AT EACH PANEL POINT SEE NOTES! 2'-0" 2'-0" 12'-4" GSAS MODULE CLAMP AT EACH CROSSING POINT SOLAR MODULE CHANNEL NUT SS.FENDER WASHER 1-1/2" SS. CLAMP UNISTRUT CHANNEL UNISTRUT CHANNEL MODULE MODULE SS. CLAMP MODULE MODULE UNISTRUT EXISTING RAFTER EXIST. SHEETING AND MEMBRANE SS EMBED 1.5” MIN INTO RAFTER. USE FULL-DEPTH PILOT HOLE FLANGE FILL W/ POLYURETHAN SEALANT V.I.F. PV MODULE V.I.F. SHEET NO: PUBLISHED: SHEET NAME: DRAWN: CHECKED: SB AG ENLARGED VIEWING & HYPERLINKS: PRINT VERSION OF THIS PLAN PROVIDES MINIMUM INFORMATION NEEDED BY USERS. ELECTRONIC VERSION (EV) PROVIDES MAGNIFIED VIEWING UP TO 6400%. EV ALSO PROVIDES HYPERLINK ACCESS TO OEM MANUALS AND ABUNDANT OTHER SUPPLEMENTARY INFORMATION.EV MAY BE ACCESSED AT: WWW.GEZELMANPE.COM/PV/0196P.NES_YO_Plantation_FL.dwg REVISIONS: 01 SCALE: N.T.S. IMAGERY MAY NOT CORRECTLY INDICATE CURRENT POTENTIAL SHADING OF PROPERTY. PARCEL - (AHJ PROPERTY APPRAISER) 02 SCALE: N.T.S. AERIAL VIEW OF PROPERTY I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATIC DRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL. 05 SCALE: VARIES EXISTING TYP ROOF TRUSS, DISPLAYED FOR INFORMATION. NOT DESIGNED BY THIS ENGINEER! CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWN HERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THE ARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADING OF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION! COPY RIGHT & INTELLECTUAL PROPERTY NOTICE THIS PLAN SET IS COPY RIGHT PROTECTED AND CONTAINS INTELLECTUAL PROPERTY WHICH BELONGS TO ALLEN GEZELMAN PE. ACCESS IS GIVEN TO THE INFORMATION HEREON SOLELY FOR THE PURPOSE OF COMPLETION OF THE PROJECT FOR WHICH IT IS INTENDED. NO OTHER USE MAY BE MADE OF THE INFORMATION, DRAWINGS, OR IDEAS HEREON WITHOUT THE EXPRESS , WRITTEN, PERMISSION OF ALLEN GEZELMAN PE ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 OR PROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF OWNER: 381 NW 135 AVE, PLANTATION, FL 33325 YU, KATE THIS PLAN IS ONLINE FOR REVIEW @ WWW.GEZELMANPE.COM/PV/0196P.NES_YU_PLANTATION_FL.PDF CONTACT DESIGN TEAM @ www.GezelmanPE.com ALLEN GEZELMAN 16502 HANNA RD. LUTZ, FLORIDA 33549 PH. 813 650 7246 FX. 866 397 9050 Allen@Gezelman PE.COM www.GezelmanPE.com I CERTIFY THAT THIS DESIGN & SPECIFICATIONS MEET THE FBC2007 W/09 SUPP. AND NATIONAL ELECTRICAL CODE. CODE VERIFY 06 SCALE: 3/16 = 1'-0" ROOF LAYOUT PLAN - 24 OR LESS PANELS PHOTO-VOLTAIC (PV) SYSTEM STRUCTURAL INSTALLATION NOTES - ELECTRICAL DESIGN BY OTHERS: THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY USERS (AHJ -AUTHORITY HAVING JURISDICTION AND INSTALLERS). USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC VERSION) OF THIS PLAN THRU HYPERLINK ADDRESS PROVIDED ON THIS PLAN. ACTIVE HYPERLINKS EMBEDDED IN EV PROVIDE SEAMLESS ACCESS TO VALUABLE SUPPLEMENTARY INFORMATION - SUCH AS OEM (ORIGINAL EQUIPMENT MANUFACTURER/DISTRIBUTOR) INSTRUCTIONS. EV ALSO ALLOWS VIEWER TO STUDY THE PLAN AND OEM DETAILS AT A MAGNIFICATION OF HIS CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. WIND IS THE ONLY LOAD OF SIGNIFICANCE FOR A ROOF-MOUNTED PV SYSTEM. PV MODULES (INCLUDING MOUNTING HARDWARE & RACKING) IMPOSE A LOAD OF LESS THAN 4-PSF. THESE DRAWINGS AND ENGINEERING CONTAINED HEREIN PROVIDE SITE SPECIFIC INSTALLATION DETAILS FOR A PV SYSTEM ON SUBJECT PROPERTY. 1. EACH PV MODULE SHALL ATTACH TO THREE UNISTRUT P1000T HOT GALVANIZED MOUNTING RAILS AT ALL CROSSING POINTS WITH A GSAS MODULE CLAMP USING ¼-INCH STAINLESS STEEL BOLTS & CHANNEL NUTS. ADJACENT MODULES SHARE CLAMPS. 2. UNISTRUT RAILS SHALL PARALLEL ROOF STRUCTURAL FRAMING DIRECTLY ABOVE TRUSSES AND BE ATTACHED INTO TRUSSES AT EACH PANEL POINT CROSSED USING 5/16-DIAMETER STAINLESS STEEL LAGS THRU 1-INCH GALVANIZED FLOOR FLANGES FILLED WITH NOA/PCA APPROVED POLYURETHANE ROOF SEALANT. 3. CONTRACTOR TO USE CARE TO HIT PANEL POINTS AT CENTERS. DRILL 3/16-INCH PILOT HOLES. FILL FLOOR FLANGE WITH ROOF SEALANT TO SERVE AS PITCH POCKET, E.G. LAG THRU SEALANT FILLED, GALVANIZED, 1-INCH FLOOR FLANGE. LAGS SHALL PENETRATE TRUSS TOP CORD 1-1/2-INCHES MINIMUM. 4. CONTRACTOR SHALL ADHERE TO REQUIREMENTS OF CHAPTER 15 CURRENT FBC (FLORIDA BUILDING CODE) AND BEST PRACTICES OF THE NRCA (NATIONAL ROOFING CONTRACTORS ASSOCIATION) ROOFING & WATERPROOFING MANUAL TO ENSURE THAT THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKS AT INITIAL INSTALLATION OR AS THE SYSTEM “AGES”. 5. CONTRACTORS, INSPECTORS, & PLAN REVIEWERS HAVING QUESTIONS, CONTACT EOR (ENGINEER OF RECORD) DIRECTLY - OFFICE: 813 909 1956, CELL: 813 650 7246 E-MAIL: [email protected] WIND CONTRACTOR: DOMINICK C. PORRETTO VP A NATIONAL ELECTRIC SERVICE, INC. 3881 CRYSTAL LAKE DR. SUITE #4 POMPANO BEACH, FL 33064 PH. 954-448-1529 ANATIONALELECTRICSERVICE.COM CVC 56852 - STATE LICENSED SOLAR CONTRACTOR 03 SCALE: NTS PHOTO OF RESIDENCE - INSTALLATION SIDE INSTALLATION LOCATION INSTALLATION LOCATION SOUTH SIDE INSTALLATION OF A ROOF MOUNT RENEWABLE ENERGY SYSTEM THE YU HOUSE 381 NW 135 AVE, PLANTATION, FL 33325 SPEED: 140 MPH EXPOSURE: C IP CATEGORY: II UPLIFT(PSF) : ENTIRE ROOF PZ2-55.8 PSF; PZ3- NOT ALLOWED STRUCTURAL LOAD FROM EQUIP < 4PSF ASCE PRESSURE ZONES: HTTP://UNIRAC.COM/PDF/II227.PDF Jan. 8, 12 PV MODULE: CONTRACTOR CHOICE DESIGNED PER: ASCE 7-05, 2010 NEC, FBC2007 W/09 SUPP. AHJ: BROWARD COUNTY, FOLIO # 504002030600 INSTALLATION LOCATION UNISTRUT TO PV PANEL CONNECTION W/ GSAS SCALE: 3" = 1'-0" GEZELMAN SOLAR ANCHOR SYSTEM (GSAS) HTTP://GEZELMANPE.COM/REFERENCE/CLAMPPLATE.PDF UNISTRUT P1000T HG (Hot Galvanized) FLANGE RAIL CONNECTION (TOP VIEW) FLANGE RAIL CONNECTION (CAMERA VIEW) GSAS MODULE CLAMP TO RAIL CONNECTION TYP 1" GALV. FLOOR FLANGE W/ SEALANT 04 SCALE: VARIES RACKING - UNISTRUT WITH GSAS MODULE CLAMPS RACKING TO TRUSS SECTION SCALE: 3" = 1'-0"

OWNER: THIS PLAN IS ONLINE FOR REVIEW · lutz, florida 33549 ph. 813 650 7246 fx. 866 397 9050 allen@gezelman pe.com i certify that this design & specifications meet the fbc2007 w/09

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OWNER: THIS PLAN IS ONLINE FOR REVIEW · lutz, florida 33549 ph. 813 650 7246 fx. 866 397 9050 allen@gezelman pe.com i certify that this design & specifications meet the fbc2007 w/09

62'-0"

PZ3

PZ3

PZ3

PZ3

ENTIRE INSTALLATIONTREATED AS PZ2

2'-0" 2'-0" 2'-0"2'-0"1'-4"1'-4"1'-4"

4'-0" 4'-0"

DN

3/1

2D

N 3

/12

RIDGE

EAVEG

AB

LE

# 381 1STORY SFMANUFACUTRED HOME

ASP SHINGLE ROOF SLOPE 3/12

EXISTING ROOF TRUSSES SAME ON SOUTH SIDE BUT NOT SHOWN HERE (TYP)

CENTER EACH RAIL ONEXISTING ROOF TRUSS (TYP) SEE NOTES!

RAILS MOUNTED THRU 1" GALV FLOOR FLANGEATTACHED INTO TRUSSES AT EACH PANEL POINTSEE NOTES!

2'-0" 2'-0"

12

'-4

"

GSAS MODULE CLAMP ATEACH CROSSING POINT

SOLAR MODULE

CHANNEL NUT

SS.FENDER WASHER 1-1/2"

SS. CLAMP

UNISTRUT CHANNEL

UNISTRUT CHANNEL

MODULE MODULE

SS. CLAMP

MODULEMODULE

UNISTRUT

EXISTING RAFTER

EXIST. SHEETINGAND MEMBRANE

SS EMBED 1.5” MIN INTO RAFTER.USE FULL-DEPTH PILOT HOLE

FLANGEFILL W/ POLYURETHAN

SEALANT

V.I

.F.

PV MODULE

V.I

.F.

SHEET NO:

PUBLISHED:

SHEET NAME:

DRAWN: CHECKED:SB AG

EN

LAR

GE

D V

IEW

ING

& H

YP

ER

LIN

KS

:P

RIN

T V

ER

SIO

N O

F T

HIS

PLA

N P

RO

VID

ES

MIN

IMU

M I

NF

OR

MA

TIO

N N

EE

DE

D B

Y U

SE

RS

.

ELE

CT

RO

NIC

VE

RS

ION

(E

V)

PR

OV

IDE

S M

AG

NIF

IED

VIE

WIN

G U

P T

O 6

40

0%

. E

V A

LSO

PR

OV

IDE

S H

YP

ER

LIN

KA

CC

ES

S T

O O

EM

MA

NU

ALS

AN

D A

BU

ND

AN

T O

TH

ER

SU

PP

LEM

EN

TA

RY

IN

FO

RM

AT

ION

.EV

MA

Y B

E

AC

CE

SS

ED

AT

: W

WW

.GE

ZE

LMA

NP

E.C

OM

/PV

/0

19

6P

.NE

S_

YO

_P

lan

tati

on

_F

L.d

wg

REVISIONS:

01SCALE: N.T.S. IMAGERY MAY NOT CORRECTLY INDICATE CURRENT POTENTIAL SHADING OF PROPERTY.

PARCEL - (AHJ PROPERTY APPRAISER)02

SCALE: N.T.S.

AERIAL VIEW OF PROPERTY

I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND UPLIFT AND LATERAL FORCES ANDEQUIPMENT DEAD LOADS. THIS IS ATTESTED TO BY MY SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT.ELECTRICAL SPECIFICATIONS: CONFORMS TO THE REQUIREMENTS OF THE 2010 NATIONAL ELECTRICAL CODE. THE ELECTRICAL SCHEMATICDRAWING IS A TYPICAL REPRESENTATION, CERTAIN DETAILS OF THIS PROJECT MAY DIFFER, REFER TO OEM LITERATURE WHICH SHALL PREVAIL.

05SCALE: VARIES

EXISTING TYP ROOF TRUSS, DISPLAYED FOR INFORMATION. NOT DESIGNED BY THIS ENGINEER!

CONTRACTOR RESPONSIBLE TO VERIFY THE FIT OF THIS ARRAY PRIOR TO INSTALLATION: THE SOLAR MODULE ARRAY SHOWNHERE IS BASED ON THE FIELD DATA PROVIDED BY THE CONTRACTOR. CONTRACTOR SHALL CONTACT THE ENGINEER IF THEARRAY MAY NOT FIT AS PROJECTED. SATELLITE IMAGERY SHOWN MAY NOT CORRECTLY INDICATE POTENTIAL CURRENT SHADINGOF PROPERTY. CONTRACTOR RESPONSIBLE TO VERIFY SUN EXPOSURE AND SHADING OF INSTALLATION PRIOR TO INSTALLATION!

C

OP

Y R

IGH

T &

IN

TE

LLE

CT

UA

L P

RO

PE

RT

Y N

OT

ICE

•T

HIS

PLA

N S

ET

IS

CO

PY

RIG

HT

PR

OT

EC

TE

D A

ND

CO

NT

AIN

S I

NT

ELL

EC

TU

AL

PR

OP

ER

TY

WH

ICH

BE

LON

GS

TO

ALL

EN

GE

ZE

LMA

N P

E.

•A

CC

ES

S I

S G

IVE

N T

O T

HE

IN

FO

RM

AT

ION

HE

RE

ON

SO

LELY

FO

R T

HE

PU

RP

OS

E O

F C

OM

PLE

TIO

N O

F T

HE

PR

OJE

CT

FO

R W

HIC

H I

T I

S I

NT

EN

DE

D.

•N

O O

TH

ER

US

E M

AY

BE

MA

DE

OF

TH

E I

NF

OR

MA

TIO

N,

DR

AW

ING

S,

OR

ID

EA

S H

ER

EO

N W

ITH

OU

T T

HE

EX

PR

ES

S,

WR

ITT

EN,

PE

RM

ISS

ION

OF

ALL

EN

GE

ZE

LMA

N P

E

ALL AFFIDAVITS, DESIGNS, OPINIONS, CALCULATIONS & OTHER ENGINEERING SERVICES PROVIDED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON ANY AND ALL PROJECTS ARE SUBJECT TO THE PROVISIONS OF EJCDC

C-700 (ENGINEERS JOINT CONSTRUCTION DOCUMENT COMMITTEE - STANDARD GENERAL CONDITIONS OF THE CONSTRUCTION CONTRACT) CURRENT AT THE TIME. THOSE OBJECTING TO SAID EJCDC C-700 ORPROVISIONS THEREOF ARE DIRECTED NOT TO USE THE AFFIDAVIT, DESIGN, OPINION, CALCULATION OR OTHER ENGINEERING SERVICE OFFERED BY ALLEN GEZELMAN PE AND HIS ASSOCIATES ON THE PROJECT. EJCDC

C-700 MAY BE VIEWED AT: HTTP://GEZELMANPE.COM/REFERENCE/AG/C-700.PDF

OWNER:

381 NW 135 AVE, PLANTATION, FL 33325

YU, KATE THIS PLAN IS ONLINE FOR REVIEW @

WWW.GEZELMANPE.COM/PV/0196P.NES_YU_PLANTATION_FL.PDF

CO

NT

AC

T D

ES

IGN

TE

AM

@

ww

w.G

eze

lma

nP

E.c

om

ALLEN GEZELMAN16502 HANNA RD.LUTZ, FLORIDA 33549

PH. 813 650 7246FX. 866 397 9050Allen@Gezelman PE.COM

www.GezelmanPE.com

I CERTIFY THAT THIS DESIGN &SPECIFICATIONS MEET THE FBC2007

W/09 SUPP. AND NATIONALELECTRICAL CODE.

CO

DE

VE

RIF

Y

06SCALE: 3/16 = 1'-0"

ROOF LAYOUT PLAN - 24 OR LESS PANELS

PHOTO-VOLTAIC (PV) SYSTEM STRUCTURAL INSTALLATION NOTES - ELECTRICAL DESIGN BY OTHERS:

THE DETAILS SPECIFIED ON THIS “PAPER” PLAN ARE CONSIDERED TO BE THE MINIMUM NEEDED BY USERS (AHJ-AUTHORITY HAVING JURISDICTION AND INSTALLERS). USERS ARE ENCOURAGED TO ACCESS EV (ELECTRONIC

VERSION) OF THIS PLAN THRU HYPERLINK ADDRESS PROVIDED ON THIS PLAN. ACTIVE HYPERLINKS EMBEDDEDIN EV PROVIDE SEAMLESS ACCESS TO VALUABLE SUPPLEMENTARY INFORMATION - SUCH AS OEM (ORIGINAL

EQUIPMENT MANUFACTURER/DISTRIBUTOR) INSTRUCTIONS. EV ALSO ALLOWS VIEWER TO STUDY THE PLANAND OEM DETAILS AT A MAGNIFICATION OF HIS CHOICE UP TO 6400%. IF A CONFLICT SHOULD OCCUR BETWEEN

A DRAWING AND/OR SPECIFICATION HEREON AND AN OEM DETAIL, OEM SHALL PREVAIL. WIND IS THE ONLYLOAD OF SIGNIFICANCE FOR A ROOF-MOUNTED PV SYSTEM. PV MODULES (INCLUDING MOUNTING HARDWARE

& RACKING) IMPOSE A LOAD OF LESS THAN 4-PSF. THESE DRAWINGS AND ENGINEERING CONTAINED HEREINPROVIDE SITE SPECIFIC INSTALLATION DETAILS FOR A PV SYSTEM ON SUBJECT PROPERTY.

1. EACH PV MODULE SHALL ATTACH TO THREE UNISTRUT P1000T HOT GALVANIZED MOUNTING RAILS ATALL CROSSING POINTS WITH A GSAS MODULE CLAMP USING ¼-INCH STAINLESS STEEL BOLTS & CHANNELNUTS. ADJACENT MODULES SHARE CLAMPS.

2. UNISTRUT RAILS SHALL PARALLEL ROOF STRUCTURAL FRAMING DIRECTLY ABOVE TRUSSES AND BE

ATTACHED INTO TRUSSES AT EACH PANEL POINT CROSSED USING 5/16-DIAMETER STAINLESS STEEL LAGS

THRU 1-INCH GALVANIZED FLOOR FLANGES FILLED WITH NOA/PCA APPROVED POLYURETHANE ROOFSEALANT.

3. CONTRACTOR TO USE CARE TO HIT PANEL POINTS AT CENTERS. DRILL 3/16-INCH PILOT HOLES. FILL FLOORFLANGE WITH ROOF SEALANT TO SERVE AS PITCH POCKET, E.G. LAG THRU SEALANT FILLED, GALVANIZED,

1-INCH FLOOR FLANGE. LAGS SHALL PENETRATE TRUSS TOP CORD 1-1/2-INCHES MINIMUM.

4. CONTRACTOR SHALL ADHERE TO REQUIREMENTS OF CHAPTER 15 CURRENT FBC (FLORIDA BUILDINGCODE) AND BEST PRACTICES OF THE NRCA (NATIONAL ROOFING CONTRACTORS ASSOCIATION) ROOFING& WATERPROOFING MANUAL TO ENSURE THAT THE SOLAR INSTALLATION DOES NOT CAUSE ROOF LEAKSAT INITIAL INSTALLATION OR AS THE SYSTEM “AGES”.

5. CONTRACTORS, INSPECTORS, & PLAN REVIEWERS HAVING QUESTIONS, CONTACT EOR (ENGINEER OFRECORD) DIRECTLY - OFFICE: 813 909 1956, CELL: 813 650 7246

E-MAIL: [email protected]

WIN

DCONTRACTOR:

DOMINICK C. PORRETTO VP

A NATIONAL ELECTRIC SERVICE, INC.

3881 CRYSTAL LAKE DR. SUITE #4

POMPANO BEACH, FL 33064

PH. 954-448-1529

ANATIONALELECTRICSERVICE.COM

CVC 56852 - STATE LICENSED SOLAR

CONTRACTOR

03SCALE: NTS

PHOTO OF RESIDENCE - INSTALLATION SIDE

INSTALLATION LOCATION INSTALLATION LOCATION SOUTH SIDE

INS

TA

LLA

TIO

N O

F A

RO

OF

MO

UN

T

RE

NE

WA

BLE

EN

ER

GY

SY

ST

EM

TH

E Y

U H

OU

SE

38

1 N

W 1

35

AV

E,

PLA

NT

AT

ION

, F

L 3

33

25

SPEED: 140 MPH

EXPOSURE: C

IP CATEGORY: II

UPLIFT(PSF) : ENTIRE ROOF PZ2-55.8 PSF; PZ3- NOT ALLOWED

STRUCTURAL LOAD FROM EQUIP < 4PSF

ASCE PRESSURE ZONES: HTTP://UNIRAC.COM/PDF/II227.PDF

Jan. 8, 12

PV MODULE: CONTRACTOR CHOICE

DESIGNED PER: ASCE 7-05, 2010 NEC,FBC2007 W/09 SUPP.

AHJ: BROWARD COUNTY, FOLIO # 504002030600

INSTALLATION LOCATION

UNISTRUT TO PV PANEL CONNECTION W/ GSASSCALE: 3" = 1'-0"

GEZELMAN SOLAR ANCHOR SYSTEM (GSAS)

HTTP://GEZELMANPE.COM/REFERENCE/CLAMPPLATE.PDF

UNISTRUT P1000T HG (Hot Galvanized) FLANGE RAIL CONNECTION (TOP VIEW)FLANGE RAIL CONNECTION (CAMERA VIEW)GSAS MODULE CLAMP TO RAIL CONNECTIONTYP 1" GALV. FLOOR FLANGE W/ SEALANT

04SCALE: VARIES

RACKING - UNISTRUT WITH GSAS MODULE CLAMPS

RACKING TO TRUSS SECTIONSCALE: 3" = 1'-0"

Siggi
Snapshot
Siggi
Callout
LAG INTO TRUSS NEAR TRUSS JOINTS
Siggi
Arrow
Siggi
Arrow