T-PROJEKT d.o.o. Čazma Trg čazmanskog kaptola 9, tel. 043/772-522
ELABORAT BROJ: 60/2016. SIJEČANJ 2017.
Z.O.P.: 60/2016.
INVESTITOR: BJELOVARSKO-BILOGORSKA ŽUPANIJA DR. ANTE STARČEVIĆA 8, BJELOVAR
GRAĐEVINE: ZGRADA OSNOVNE ŠKOLE I ŠKOLSKA SPORTSKA DVORANA U ČAZMI
LOKACIJA: ČAZMA, ALOJZA VULINCA 22 K.Č. 2625/1 (956) K.O. ČAZMA
GLAVNI PROJEKT ENERGETSKE OBNOVE ZGRADE
MAPA 1 b
ARHITEKTONSKI PROJEKT
GLAVNI PROJEKTANT
RAJKA TORBAŠINOVIĆ ING. ARH. OVLAŠTENI ARHITEKT
PROJEKTANT
RAJKA TORBAŠINOVIĆ ING. ARH. OVLAŠTENI ARHITEKT
DIREKTOR:
RAJKA TORBAŠINOVIĆ ING. ARH.
U Čazmi, 12.01.2018.
T-PROJEKT d.o.o. Čazma Str.2
SADRŽAJ:
A. OPĆI DIO
POPIS MAPA GLAVNOG PROJEKTA RJEŠENJE TRGOVAČKOG SUDA PRESLIK RJEŠENJA OVLAŠTENOG INŽENJERA RJEŠENJE O IMENOVANJU GLAVNOG PROJEKTANTA POPIS PRIMIJENJENIH PROPISA
B. ARHITEKTONSKI SNIMAK POSTOJEĆEG STANJA
- TEHNiČKI OPIS - SITUACIJA NA KOPIJI KATASTARSKOG PLANA
- TLOCRT PRIZEMLJA -DVORANA - TLOCRT PRIZEMLJA - HODNIK - TLOCRT I I II KATA - TLOCRT KROVNIH PLOHA - PRESJEK A-A - PRESJEK B-B - PRESJEK C-C - PRESJEK D-D, E-E, F-F - ISTOČNA I ZAPADNA FASADA - SJEVERNA I JUŽNA FASADA
C. PROJEKTIRANE MJERE ENERGETSKE UČINKOVITOSTI
- TEHNiČKI OPIS
- TLOCRT PRIZEMLJA -DVORANA - TLOCRT PRIZEMLJA - HODNIK - TLOCRT I I II KATA - TLOCRT KROVNIH PLOHA - PRESJEK A-A - PRESJEK B-B - PRESJEK C-C - PRESJEK D-D, E-E, F-F - ISTOČNA I ZAPADNA FASADA - SJEVERNA I JUŽNA FASADA - FASADE HODNIKA - SHEME STOLARIJE
D. PRORAČUN ENERGETSKIH POTREBA - POSTOJEĆE STANJE - PROJEKTIRANO STANJE - PROGRAM KONTROLE I OSIGURANJA KVALITETE - REKAPITULACIJA UŠTEDE ENERGIJE
T-PROJEKT d.o.o. Čazma Str.3
PREGLED MAPA PROJEKTA
MAPA Ia - ARHITEKTONSKI PROJEKT - ŠKOLA MAPA Ib - SPORTSKA DVORANA I SPOJNI HODNIK MAPA II - PROJEKT ELEKTROINSTALACIJA
T-PROJEKT d.o.o. Čazma Str.4
IMENOVANJE GLAVNOG PROJEKTANTA
Temeljem čl. 52. Zakona o gradnji ( NN 153/13) Imenuje se za glavnog projektanta Rajka Torbašinović inž. arh. Tvrtka i adresa projektanta: T-projekt d.o.o. Čazma, trg Čazmanskog kaptola 9 Oznaka rješenja o upisu u imenik : Klasa UP/I-350-07/91-01/739 Zagreb, 27.listopada 1999. god. Stručni smjer: Ovlašteni arhitekt Redni broj: 1138 Glavni projektant je odgovoran za cjelovitost i međusobnu usklađenost projekata. Investitor
T-PROJEKT d.o.o. Čazma Str.5
POPIS PRIMIJENJENIH PROPISA
Zakon o gradnji (NN 153/13);
Zakon o prostornom uređenju (NN 153/13);
Zakon o građevnim proizvodima (NN 76/13, 30/14);
Zakon o komori arhitekata i komorama inženjera u graditeljstvu i prostornom uređenju (NN 78/15);
Zakon o poslovima i djelatnostima prostornog uređenja i gradnje (NN 78/15);
Zakon o postupanju s nezakonito izgrađenim zgradama (NN 86/12, 143/13);
Pravilnik o osiguranju pristupačnosti građevina osobama s invaliditetom i smanjene pokretljivosti (NN 78/13);
Pravilniku o obveznom sadržaju i opremanju projekata građevina (NN 64/14, 41/15, 105/15, 61/16);
Zakon o građevinskoj inspekciji (NN 153/13);
Zakon o energetskoj učinkovitosti (NN 127/14);
Pravilnik o energetskim pregledima građevina i energetskom certificiranju zgrada (NN 81/12, 29/13, 78/13);
Pravilnik o energetskom pregledu zgrade i energetskom certificiranju (NN 48/14, 150/14, 133/15, 22/16, 49/16, 87/16); Tehnički propis o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama (NN 128/15);
Zakon o zaštiti na radu (NN 71/14, 118/14, 154/14);
Zakon o zaštiti i očuvanju kulturnih dobara (NN 69/99, 151/03, 157/03, 87/09, 88/10, 61/11, 25/12, 136/12, 157/13, 152/14);
Uredba o izmjenama Zakona o zaštiti i očuvanju kulturnih dobara (NN 98/15)
Zakon o Fondu za zaštitu okoliša i energetsku učinkovitost (NN 107/03, 144/12);
T-PROJEKT d.o.o. Čazma Str.6
Ostali podzakonski akti i tehnički propisi doneseni na temelju gore navedenih zakona
POPIS HRVATSKIH NORMI I DRUGIH TEHNIČKIH SPECIFIKACIJA ZA PRORAČUNE GRAĐEVNIH DIJELOVA ZGRADE I ZGRADE KAO CJELINE
NORME ZA PRORAČUN
HRN EN 410:2011 Staklo u graditeljstvu -- Određivanje svjetlosnih i sunčanih značajka ostakljenja (EN 410:2011)
HRN EN 673:2011 Staklo u graditeljstvu -- Određivanje koeficijenta prolaska topline (U vrijednost) -- Proračunska metoda (EN 673:2011)
HRN EN ISO 6946:2008 Građevni dijelovi i građevni dijelovi zgrade -- Toplinski otpor i koeficijent prolaska topline -- Metoda proračuna (ISO 6946:2007; EN ISO 6946:2007)
HRN EN ISO 9836:2011 Standardi za svojstva zgrada -- Definiranje i proračun površina i prostora (ISO 9836:2011)
HRN EN ISO 10077-1:2008 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006; EN ISO 10077-1:2006)
HRN EN ISO 10077-1:2008/Ispr.1:2010 Toplinska svojstva prozora, vrata i zaslona -- Proračun koeficijenta prolaska topline -- 1. dio: Općenito (ISO 10077-1:2006/Cor 1:2009; EN ISO 10077-1:2006/AC:2009)
HRN EN ISO 10211:2008 Toplinski mostovi u zgradarstvu -- Toplinski tokovi i površinske temperature -- Detaljni proračuni (ISO 10211:2007; EN ISO 10211:2007)
HRN EN ISO 10456:2008 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablične projektne vrijednosti i postupci određivanja nazivnih i projektnih toplinskih vrijednosti (ISO 10456:2007; EN ISO 10456:2007)
HRN EN 12464-1:2012 Svjetlo i rasvjeta -- Rasvjeta radnih mjesta -- 1. dio: Unutrašnji radni prostori (EN 12464-1:2011)
HRN EN 12524:2002 Građevni materijali i proizvodi -- Svojstva s obzirom na toplinu i vlagu -- Tablice projektnih vrijednosti (EN 12524:2000)
HRN EN 12831:2004 Sustavi grijanja u građevinama -- Postupak proračuna normiranoga toplinskog opterećenja (EN 12831:2003)
HRN EN ISO 13370:2008 Toplinske značajke zgrada -- Prijenos topline preko tla -- Metode proračuna (ISO 13370:2007; EN ISO 13370:2007)
T-PROJEKT d.o.o. Čazma Str.7
HRN EN 13779:2008 Ventilacija u nestambenim zgradama -- Zahtjevi za sustave ventilacije i klimatizacije (EN 13779:2007)
HRN EN ISO 13788:2002 Značajke građevnih dijelova i građevnih dijelova zgrada s obzirom na toplinu i vlagu -- Temperatura unutarnje površine kojom se izbjegava kritična vlažnost površine i unutarnja kondenzacija -- Metode proračuna (ISO 13788:2001; EN ISO 13788:2001)
HRN EN ISO 13789:2008 Toplinske značajke zgrada -- Koeficijenti prijelaza topline transmisijom i ventilacijom -- Metoda proračuna (ISO 13789:2007; EN ISO 13789:2007)
HRN EN ISO 13790:2008 Energetska svojstva zgrada -- Proračun potrebne energije za grijanje i hlađenje prostora (EN ISO 13790:2008)
HRN EN ISO 14683:2008 Toplinski mostovi u zgradarstvu -- Linearni koeficijent prolaska topline -- Pojednostavljena metoda i utvrđene vrijednosti (ISO 14683:2007; EN ISO 14683:2007)
HRN EN 15193:2008 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007)
HRN EN 15193:2008/Ispr.1:2011 Energijska svojstva zgrade -- Energijski zahtjevi za rasvjetu (EN 15193:2007/AC:2010)
HRN EN 15232:2012 Energijske značajke zgrada -- Utjecaj automatizacije zgrada, nadzor i upravljanje zgradama (EN 15232:2012)
HRN EN 15251:2008 Ulazni mikroklimatski parametri za projektiranje i ocjenjivanje energijskih značajka zgrada koji se odnose na kvalitetu zraka, toplinsku lagodnost, osvjetljenje i akustiku (EN 15251:2007)
HRN EN 674:2012 Staklo u graditeljstvu -- Određivanje koeficijenta prolaska topline (U-vrijednost) -- Metoda sa zaštićenom vrućom pločom (EN 674:2011)
HRN EN 1026:2001 Prozori i vrata -- Propusnost zraka -- Metoda ispitivanja (EN 1026:2000)
HRN EN 12207:2001 Prozori i vrata -- Propusnost zraka -- Razredba (EN 12207:1999)
HRN EN ISO 12412-2:2004 Toplinske značajke prozora, vrata i zaslona -- Određivanje koeficijenta prolaska topline metodom vruće komore -- 2. dio: Okviri (EN 12412-2:2003)
HRN EN ISO 12567-1:2011 Toplinske značajke prozora i vrata -- Određivanje prolaza topline metodom vruće komore -- 1. dio: Prozori i vrata u cjelini (ISO 12567-1:2010+Cor 1:2010; EN ISO 12567-1:2010+AC:2010)
T-PROJEKT d.o.o. Čazma Str.8
HRN EN 13829:2002 Toplinske značajke zgrada -- Određivanje propusnosti zraka kod zgrada -- Metoda razlike tlakova (ISO 9972:1996, preinačena; EN 13829:2000)
T-PROJEKT d.o.o. Čazma Str.9
A) ARHITEKTONSKI SNIMAK POSTOJEĆEG STANJA ZA ZGRADU SPORTSKE DVORANE
I SPOJNOG HODNIKA
T-PROJEKT d.o.o. Čazma Str.10
1. TEHNIČKI OPIS
Opis zgrade i energetskih sustava
Zgrada sportske dvorane je građena 1980. kao samostalni objekt, ali je je između
1995. i 2000. godine izgrađen spojni hodnik sa Osnovnom školom Čazma. Dvorana sa školom jednu čini energetsku funkcionalnu cjelinu : Dio zgrade koji predstavlja ETC ima zaseban volumen u odnosu na drugi dio zgrade sa kojim je povezan spojnim hodnikom.
Dvoranu koriste osnovna i srednja /škola Čazma za održavanje nastave tjelesne i
zdravstvene kulture, ali se dvorana koristi i za razne sportske aktivnosti (sportske
rekreacije i sl).
Građevina se sastoji od dvorane sa tribinama i pripadajućeg prostora dvorane
(spremište sprava, garderobe, sanitarije, kotlovnica, galerija). Svi prostori su grijani ,
a spojni hodnik se također zagrijava strujanjem toplog zraka između oba objekta.
Dvorana ima samo prizemnu etažu, a ostali dio zgrade prizemlje i 2 kata.
Nosiva konstrukcija dvorane su montažni armirano betonski stupovi, zidovi od
armiranog betona obzidani fasadnom opekom i zidovi od opeke, ojačani armirano
betonskim serklažima. Pod dvorane je elastični drveni pod za dvorane, a ostali
podovi su betonske ploče izvedene bez toplinske izolacije. Krovište dvorane je
metalna rešetka sa donje strane zatvorena brodskim podom, a krov garderoba i
sanitarija te spojnog hodnika je masivni neprohodni ravni krov. Stropovi između
etažasu monolitne armirano betonske ploče.
Stolarija je metalna bez prekinutog toplinskog mosta, 1-struko staklo, kopilit, PVC 2-
struko staklo low E i metalna vrata. Ne koristi se nikakva zaštita od sunca.
Grijanje građevine izvedeno je centralno pomoću dva toplovodna sustava. Prvi
sustav čine dva standardna plinska kotla. Drugi sustav grijanja izveden je pomoću
toplinske energije koja se proizvodi u obližnjem pogonu za preradu drva.
Proizvedena toplinska energija transportira se putem toplovoda do kotlovnice škole i
predaje distributivnom sustavu škole. Sustav hlađenja izveden je djelomično pomoću
split sustava.
Ventilacija građevine izvedena je prirodnim i mehaničkim putem. Prirodno ventiliranje
ostvaruje se otvaranjem ili zakretanjem prozora, vrata, te građevinskih otvora.
Mehanička ventilacija izvedena je pomoću dva odsisna ventilatora u dvoranu za
vježbanje.
Za sanitarnu vodu koristi se voda iz javnog distribucijskog sustava. Hladna sanitarna
voda upotrebljava se za ispiranje sanitarnih čvorova, te za higijenske potrebe
korisnika predmetne građevine. Topla sanitarna voda priprema se centralno pomoću
spremnika tople vode I lokalno pomoću elektro bojiera.
U zgradi je izvedena cjelovita električna instalacija (podžbukna). Osvjetljenje
prostorija je prirodno i pomoću svjetiljaka sa fluorescentnim cijevima, te žaruljama sa
žarnom niti.
T-PROJEKT d.o.o. Čazma Str.11
SNIMAK POSTOJEĆEG STANJA
GRAĐEVINSKI I ARHITEKTONSKI ELEMENTI ZGRADE
Građevina je smještena unutar max. tlocrtnih dimenzija 55,00 x 32,80 m, odnosno
tlocrtne površine 1.614 m2. Spojni hodnik sa školom smješten je sa jugoistočne
strane širine 3,20 m i duljine cca 71 m.
Sljeme je položeno u pravcu istok - zapad.
Visina vijenca iznosi max. cca 8,00 m, a sljemena max. cca 11,10 m.
Veći dio krova dvorane je dvostrešni, nagiba - 14°, a pokrov profilirani lim.
Geometrijske karakteristike zgrade: Etažnost: prizemlje + I. kat + II. kat
Opis općeg stanja građevine i vanjske ovojnice građevine
Dvorana je građena 1980. godine. Dio stolarije 2015. godine zamijenjen je PVC
stolarijom, a preostala metalna je u vrlo lošem stanju te predstavlja značajne
toplinske gubitke. Na pojedim dijelovima vanjskih zidova vidi se opadanje žbuke i
tankog zaštitnog sloja betona te dolazi do izlaganja armature atmosferilijama i
djelovanju korozije.
Dio fasade sa fasadnom opekom je u dobrom stanju. Krovni limeni pokrov
postavljen je 1992. godine. Pokrov je u lošem stanju, na mjestima prokišnjava, a
sistem odvodnje oborinskih voda loše ili gotovo nikako ne funkcionira tijekom
zimskog perioda jer se voda u horizontalnim žljebovima smrzava, a takođet i po
rubovima krovišta ( cca 1 m), a prilikom topljenja leda voda ulazi pod krov
dvoranje.
Na ravnom krovu su u više navrata mijenjani vanjski slojevi izolacije, ali krov i dalje
prokišnjava, tako da je veći dio stropne konstrukcije oronuo, a na dijelu stropa je
vidljiva i armatura.
Debljina i sastav građevinskih elemenata te toplinske izolacije utvrđen je
mjerenjem ili pretpostavkom s obzirom na vrijeme i način građenja te uvidom u
dostupnu dokumentaciju.
Spušteni strop iznad dvorane je izveden od dasaka koje su ovješene o čeličnu
rešetku krovišta. Na daske je položen tankI sloj kamene vune. Spušteni strop se
nalazi i iznad većeg dijela II kata. Strop je u lošem stanju, kao i pregradni zidovi
koji su izvedeni od iverice i koji su većim dijelom propali do te mjere da stolarija
ispada iz zida. Veći dio pregradnih zidova koji je zidan punom opekom je
popucao.
KONSTRUKCIJA GRAĐEVINE I MATERIJALI
Vanjski zid čine montažni 'armirano betonski stupovi, sendvič zidovi od
armiranog betona sa 2,5 cm ekspandiranog polistirena obzidani fasadnom
opekom i zidovi od opeke bez toplinske izolacije, ojačani armirano betonskim
serklažima.
Pod na tlu dvorane je drveni elastični sportski pod, a spremišta i garderoba 2
betonske ploče između kojih je postavljena hidroizolacija, bez toplinske izolacije.
T-PROJEKT d.o.o. Čazma Str.12
Završna podna obloga dvorane je parket, a ostalih prostorija keramika, odnosno
zaglađeni beton na tribinama. Stropovi između etaža su monolitne armirano betonske ploče.
Krovni pokrov je profilirani lim na podrožnicoma postavljenim na metalnu
rešetku koja je sa donje strane zatvorena brodskim podom i mineralnom vunom.
Stolarija je metalna bez prekinutog toplinskog mosta, 1-struko staklo, kopilit,
PVC 2-struko staklo low E i metalna vrata. Ne koristi se nikakva zaštita od sunca.
Na spojnom hodniku je PVC stolarija.
T-PROJEKT d.o.o. Čazma Str.13
NACRTI POSTOJEĆEG STANJA
40 465 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 465 40
5040
30
2465
25
212
12
211
25
145
3005
30 478 25 4468 30
1920
615
600
3135
445
445 2508 525 1600 408
5485
645
100
200
120
335 100 10 533 375 628 473 25 475 25 475 25 475 25 482 619
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
508
0105
25
420
VIII
VIII
VIII
XIII
XII
XI
IX
VII
VIVI VI
VI
III
P=450 cm
30
222
30
303
30
183
120
30
120
396
120
951
25
100
45
277
95
58
420
P=43,0 m2
Caffe bar
P= 47,8 m2
Ulazni prostor
Hodnik
P= 23,7 m2
XIV
7,93 m2
7,93 m2
1,9 m2
1,9 m2
Garderoba
18,2 m2
Pranje
15,4 m2
15,4 m2
1,02 m2
1,02 m2
1,02 m21,02 m2
Hodnik
Hodnik
23,0 m2
Hodnik
23,0 m2
Pranje
15,4 m2
Garderoba
18,2 m2
Nastavnik
8,1 m2
1,9 m2
Nastavnik
8,1 m2
1,9 m2
Dvorana
1104,7 m2
P=180 cm P=180 cm
II
I
30 80
314,5
80 25 80 255 80 25 80 255 80
25
5
502 440 440 30
474,5
880
30
100
150
30
310
100210
170
80 80 170
D
35
240100
80
25
5
440 30
880
SPORTSKA DVORANA
TLOCRT PRIZEMLJA
LIST BROJ 1
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT PRIZEMLJA
P=43,0 m2
Caffe bar
P= 47,8 m2
Ulazni prostor
P=10,6 m2
Hodnik
P= 23,7 m2
14,8 m2
7,93 m2
7,93 m2
1,9 m2
1,9 m2
Garderoba
18,2 m2
Pranje
15,4 m2
Garderoba
15,4 m2
1,02 m2
1,02 m2
25,1m2
Hodnik
23,0 m2
23,0 m2
Pranje
15,4 m2
Garderoba
18,2 m2
Dvorana
1104,7 m2
2,4 m2
1,3 m2
1,3 m2
18,1m2
15,2 m2
2,1m2
2,1m2
Garderoba
15,4 m2
P=3,3 m2
P=4,8 m2
P= 9,8 m2
VZ1
VZ4
VZ4
VZ4
VZ2
VZ4
VZ4
VZ1
VZ1
VZ1
UZ1
VZ4
VZ2
VZ2
VZ2
VZ3VZ3
VZ3
X
XIVa
VZ1
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
222
30
575
25
951
120
396
120
30
120
183
30
303
30
252
153
277
45
100
25
LEGENDA
30
2465
25
212
12
211
25
145
3005
TLOCRT PRIZEMLJA
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
508
0105
25
Nastavnik
8,1 m2
1,9 m2
Nastavnik
8,1 m2
1,9 m2
LIST BROJ 2
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT PRIZEMLJA
30 80
314,5
80 25 80 255 80 25 80 255 80
25
5
25
80
502 440 440 30
474,5
880
30
100
150
30
310
100210
170
80 80 170
80 170
D
35
240100
2
5
0
80
25
5
25
80 255 80 25 80 255 80
25
5
25
80 255 80 25 80 255 80
25
5
25
80 255 80 25
440 30 440 440 30 440 440 30 440
880 180 730 180 730 180
1
8
0
7
3
0
1
8
0
7
3
0
3
80
331
80
7
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
5
2
5
3
0
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
501
2
5
8
0
2
5
5
8
0
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
80 170
170
80 170
80 170
80 170
80 170
80 170
80 170
80 170
80 170
80 80 170 1
7080
17080
80170
80170
80170
17080
170
17080
17080
17080
210100
80170
2
5
0
1
8
0
7
3
0
1
8
0
7
3
0
9
3
5
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
1
0
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
17080
80170
80170
80170
17080
17080
17080
17080
17080
17080
210100
80170
F
F
E
E
2
1
6
2
2
6
2
1
6
2
2
6
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
9
0
1
8
6
9
0
2
0
0
9
0
2
1
6
2
2
6
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
5
2
3
1
5
9
2
2
2
6
5
2
5
6
2
6
5
2
5
6
1
0
0
2
5
6
1
2
7
1
2
0
8
0
2
5
6
6
0
1
2
0
2
3
5
1
2
0
1
8
5
2
5
6
6
5
1
2
0
1
1
1
1
1
7
7
5
5
5
8
9
9
9
9
9
9
9
9
9
x
2
1
6
2
2
6
2
1
6
2
2
6
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
9
0
1
8
6
9
0
2
0
0
9
0
2
1
6
2
2
6
2
2
5
2
3
0
2
2
5
2
3
0
2
6
5
2
5
6
2
6
5
2
5
6
1
0
0
2
5
6
1
2
7
1
2
0
8
0
2
5
6
6
0
1
2
0
2
3
5
1
2
0
1
8
5
2
5
6
6
5
1
2
0
1
1
4
2
1
0
+
8
0
1
0
5
2
1
0
1
1
1
1
1
7
7
5
5
5
8
9
9
Kuhinja
Blagovaona
Kotlovnica
Ostava
WC
Spojni hodnik
Dvorana
1104,7 m2
VZ5
VZ5 VZ5
V
Z
5
V
Z
5
V
Z
5
V
Z
5
VZ5
VZ1
VZ1
VZ4
VZ3
SPOJNI HODNIK
LEGENDA
TLOCRT I KATA
40 465 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 465 40
5040
30 478 25 4468 30
135
120
30
120
63
120
30
120
63
120
30
120
63
120
30
120
63
120
30
120
183
1920
615
600
3135
1920
615
600
3135
25
100
417
58
25 418
445 2508 525 1600 408
5485
640
320
115
335 100 10 533 375 628 473 25 475 25 475
25
475 25 482 619
XIX
XVI
P=24,3 m2
Hall
P=23,8 m2
P=110,5 m2
XXI
P=450 cm
XXI XXI XXI XXI XXI XXI
30
2455
470
25
2980
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
40
428
40
25
120
XVIII
30
555
30
XVII
P=16,0 m2
Tribine
P=270,9 m2
XVXV XV XV
XVII XVII
545
1185
435
XVI
615
58
417
100
25
443 533 378
343 105 528 378
25 423 25 478 25
XVIII
XVII
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
Kancelarija
P=32,8 m2
Kancelarija
P=15,1 m2
Kancelarija
P=15,1 m2
Kancelarija
P=15,1 m2
Kancelarija
P=15,5 m2
3,1 m2
Hodnik
P=23,5 m2
P=1,8 m2
P=1,8 m2
LIST BROJ 3
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT I. I II. KATA
B
C
A
A
A
A
XVII
P=10,3 m2
P=9,7 m2
P=2,1 m2
P=15,9 m2
13,4 m2
3,1 m2
P=16,0 m2
P=10,3 m2
P=9,7 m2
P=2,1 m2
P=22,0 m2
P=18,3 m2
VZ1
VZ4
VZ4
VZ4
VZ4
VZ4
VZ4
VZ4
VZ1
VZ1
VZ1
VZ1
VZ3
VZ3
VZ3
VZ1
VZ1
VZ3
VZ4
VZ4
VZ4
VZ4
XXII
C
IV
TLOCRT II KATA
555
100
240
100
240
100
240
XXIII
XXIII XXIII XXIII
XXIII
XXIII
XXIIIXXIII
LEGENDA
TLOCRT KROVNIH PLOHA
LIST BROJ 4
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT KROVNIH PLOHA
5050
1354
1324
2678
438
615
600
528 473 3525 510
5040
240
42
179
80
179
80
268
265
273
240
20
265
16
245
800
Cem. glazura 3 cm
Vinaz
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
PRESJEK A-A
Cem. glazura 3 cm
Vinaz
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
LIST BROJ 5
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK A-A
14
Preskis 2 cm
Hidroizolacija 1 cm
Okipor 5 cm
Parna brana
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
Preskis 2 cm
Hidroizolacija 1 cm
Okipor 5 cm
Voalbit RP
Parna brana
Voalbit RP
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
VZ4
VZ4
VZ1
S3
S1
P1
P2
P2
KK1
RK1
RK1 P2
S1
P1
Cem. glazura 3 cm
Vinaz
S2
800
tribine
Drvo 1,8 cm
Mineralna vuna 5 cm
Preskis 2 cm
Hidroizolacija 1 cm
Okipor 5 cm
Voalbit RP
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
Parna brana
Voalbit RP
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
PRESJEK B-B
LIST BROJ 6
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK B-B
VZ4
S1
P1
P2
KK1
RK1
P1
P2
KK1
RK1
P2
Cem. glazura 5 cm
Beton 5 cm
Hidroizolacija
Bet. podloga 10 cm
328
116
86
30
291
4515
278
64
Drvo 1,8 cm
Mineralna vuna 5 cm
Preskis 2 cm
Hidroizolacija 1 cm
Okipor 5 cm
Voalbit RP
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
Parna brana
Voalbit RP
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
PRESJEK C-C
LIST BROJ 7
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK C-C
KK1P1
RK1
P2P2
Beton 5 cm
Hidroizolacija
P2P2
Cem. glazura 5 cm
Beton 5 cm
Hidroizolacija
Bet. podloga 10 cm
800
tribine
800
tribine
VZ4
VZ2
P1
P2
S1
KK1
RK1
tribinetribine
450
300
1
3
4
2
23
785
15
327
342
16
278
14
50
800
100
25
10
HIDROIZOLACIJA
CEM. GLAZURA 5 CM
FERT 16+5 CM
BETON U PADU
POC. OBOJENI REBRASTI LIM
PRESJEK D-D
100
20
10350
20
65
170
90
55
210
110
20
320
20
100
PRESJEK E-E
260
POC. OBOJENI REBRASTI LIM
BETON U PADU
FERT 16+5 CM
CEM. GLAZURA 5 CM
HIDROIZOLACIJA
HIDROIZOLACIJA
CEM. GLAZURA 5 CM
260
PRESJEK F-F
20
10320
20
60
170
90
40
LIST BROJ 8
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJECI KROZ SPOJNI HODNIK
PRESJECI KROZ SPOJNI HODNIK
VZ5VZ5VZ5VZ5VZ5
P3
P3
P3
RK2
RK2
RK2
POC. OBOJENI REBRASTI LIM
BETON U PADU
FERT 16+5 CM
F
O
F
O
F
O
F
O
OO
O
O
F
O
O,7
ZAPADNA FASADA
LIST BROJ 9
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
LEGENDA
O
O
SJEVERNA FASADA
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
LIST BROJ 10
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
3,76 3,76
LEGENDA
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
LIST BROJ 11
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
SJEVERNA FASADA
LEGENDA
T-PROJEKT d.o.o. Čazma Str.14
B) PROJEKTIRANE MJERE ENERGETSKE UČINKOVITOSTI
T-PROJEKT d.o.o. Čazma Str.15
PRIMIJENJENE MJERE ZA POBOLJŠANJE ENERGETSKE učinkovitostiUČINKOVITOSTI
IZOLACIJA VANJSKE OVOJNICE ZGRADE
Projektom je predviđeno: RAVNI I KOSI KROV. Ovom mjerom predviđa se toplinska izolacija ravnog krova dvorane sa vanjske strane objekta i izolacija ravnog krova hodnika sa unutarnje strane objekta, kako bi se postigao propisani koeficijent.. također se izvodi izolacija kosog krova dvorane krovnim panelima. Koeficijent prolaska topline mora biti U = < 020 W/m2K . ZIDOVI Izolacija vanjskog zida grijanog prostora etics fasadnjm sustavom U
T-PROJEKT d.o.o. Čazma Str.16
NACRTI NOVOG STANJA
40 465 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 465 40
5040
30
2465
25
212
12
211
25
145
3005
30 478 25 4468 30
1920
615
600
3135
445
445 2508 525 1600 408
5485
645
100
200
120
335 100 10 533 375 628 473 25 475 25 475 25 475 25 482 619
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
508
0105
25
420
VIII
VIII
VIII
XIII
XII
XI
VII
VIVI VI
VI
III
P=450 cm
30
222
30
303
30
183
120
30
120
396
120
951
25
100
45
277
95
58
420
P=43,0 m2
Caffe bar
P= 47,8 m2
Ulazni prostor
Hodnik
P= 23,7 m2
XIV
7,93 m2
7,93 m2
1,9 m2
1,9 m2
Garderoba
18,2 m2
Pranje
15,4 m2
15,4 m2
1,02 m2
1,02 m2
1,02 m21,02 m2
Hodnik
Hodnik
23,0 m2
Hodnik
23,0 m2
Pranje
15,4 m2
Garderoba
18,2 m2
Nastavnik
8,1 m2
1,9 m2
Nastavnik
8,1 m2
1,9 m2
Dvorana
1104,7 m2
P=180 cm P=180 cm
II
I
30 80
314,5
80 25 80 255 80 25 80 255 80
25
5
502 440 440 30
474,5
880
30
100
150
30
310
100210
170
80 80 170
D
35
240100
80
25
5
440 30
880
SPORTSKA DVORANA
TLOCRT PRIZEMLJA -NOVO STANJE
LIST BROJ 12
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT PRIZEMLJA
P=43,0 m2
Caffe bar
P= 47,8 m2
Ulazni prostor
P=10,6 m2
Hodnik
P= 23,7 m2
14,8 m2
7,93 m2
7,93 m2
1,9 m2
1,9 m2
Garderoba
18,2 m2
Pranje
15,4 m2
Garderoba
15,4 m2
1,02 m2
1,02 m2
25,1m2
Hodnik
23,0 m2
23,0 m2
Pranje
15,4 m2
Garderoba
18,2 m2
Dvorana
1104,7 m2
2,4 m2
1,3 m2
1,3 m2
18,1m2
15,2 m2
2,1m2
2,1m2
Garderoba
15,4 m2
P=7,54 m2
P= 9,8 m2
VZ1
VZ4
VZ4
VZ4
VZ2
VZ4
VZ1
VZ1
VZ1
UZ1
VZ4
VZ2
VZ2
VZ2
VZ3VZ3
VZ3
XIVa
VZ1
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
222
30
575
25
951
120
396
120
30
120
183
30
303
30
252
153
277
45
100
25
110
210
zazidati
VZ1
VZ5
NOVA PVC STOLARIJA
LEGENDA
24
98
30
2465
25
212
12
211
25
145
3005
TLOCRT PRIZEMLJA
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
508
0105
25
Nastavnik
8,1 m2
1,9 m2
Nastavnik
8,1 m2
1,9 m2
LIST BROJ 13
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT PRIZEMLJA
30 80
314,5
80 25 80 255 80 25 80 255 80
25
5
25
80
502 440 440 30
474,5
880
30
100
150
30
310
100210
170
80 80 170
80 170
D
35
240100
2
5
0
80
25
5
25
80 255 80 25 80 255 80
25
5
25
80 255 80 25 80 255 80
25
5
25
80 255 80 25
440 30 440 440 30 440 440 30 440
880 180 730 180 730 180
1
8
0
7
3
0
1
8
0
7
3
0
3
80
331
80
7
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
5
2
5
3
0
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
501
2
5
8
0
2
5
5
8
0
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
80 170
170
80 170
80 170
80 170
80 170
80 170
80 170
80 170
80 170
80 80 170 1
7080
17080
80170
80170
80170
17080
170
17080
17080
17080
210100
80170
2
5
0
1
8
0
7
3
0
1
8
0
7
3
0
9
3
5
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
5
2
5
4
1
5
2
5
4
1
5
2
5
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
4
4
0
4
4
0
3
0
1
0
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
8
0
2
5
5
2
5
8
0
2
5
5
8
0
2
5
8
0
2
5
5
17080
80170
80170
80170
17080
17080
17080
17080
17080
17080
210100
80170
F
F
E
E
2
1
6
2
2
6
2
1
6
2
2
6
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
9
0
1
8
6
9
0
2
0
0
9
0
2
1
6
2
2
6
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
2
5
2
3
0
2
5
2
3
1
5
9
2
2
2
6
5
2
5
6
2
6
5
2
5
6
1
0
0
2
5
6
1
2
7
1
2
0
8
0
2
5
6
6
0
1
2
0
2
3
5
1
2
0
1
8
5
2
5
6
6
5
1
2
0
1
1
1
1
1
7
7
5
5
5
8
9
9
9
9
9
9
9
9
9
x
2
1
6
2
2
6
2
1
6
2
2
6
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
2
2
1
2
3
0
9
0
1
8
6
9
0
2
0
0
9
0
2
1
6
2
2
6
2
2
5
2
3
0
2
2
5
2
3
0
2
6
5
2
5
6
2
6
5
2
5
6
1
0
0
2
5
6
1
2
7
1
2
0
8
0
2
5
6
6
0
1
2
0
2
3
5
1
2
0
1
8
5
2
5
6
6
5
1
2
0
1
1
4
2
1
0
+
8
0
1
0
5
2
1
0
1
1
1
1
1
7
7
5
5
5
8
9
9
Kuhinja
Blagovaona
Kotlovnica
Ostava
WC
Spojni hodnik
Dvorana
1104,7 m2
VZ5
VZ5 VZ5
V
Z
5
V
Z
5
V
Z
5
V
Z
5
VZ5
VZ1
VZ1
VZ4
VZ3
SPOJNI HODNIK
NOVA PVC STOLARIJA
LEGENDA
TLOCRT I KATA
40 465 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 470 30 465 40
5040
30 478 25 4468 30
135
120
30
120
63
120
30
120
63
120
30
120
63
120
30
120
63
120
30
120
183
1920
615
600
3135
1920
615
600
3135
25
100
417
58
25 418
445 2508 525 1600 408
5485
640
320
115
335 100 10 533 375 628 473 25 475 25 475
25
475 25 482 619
XIX
XVI
P=24,3 m2
Hall
P=23,8 m2
P=110,5 m2
XXI
P=450 cm
XXI XXI XXI XXI XXI XXI
30
2455
470
25
2980
40
215
30
303
30
303
30
303
30
303
30
303
30
303
30
215
40
428
40
25
120
XVIII
30
555
30
XVII
P=16,0 m2
Tribine
P=270,9 m2
XVXV XV XV
XVII XVII
545
1185
435
XVI
615
58
417
100
25
443 533 378
343 105 528 378
25 423 25 478 25
XVIII
XVII
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
Teretana
P=52,3 m2
P=45,3 m2
3,1 m2
Hodnik
P=23,5 m2
P=1,8 m2
P=1,8 m2
LIST BROJ 14
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT I. I II. KATA
B
C
A
A
A
A
XVII
P=10,3 m2
P=9,7 m2
P=2,1 m2
P=12,1 m2
13,4 m2
3,1 m2
P=16,0 m2
P=10,3 m2
P=9,7 m2
P=2,1 m2
P=22,0 m2
P=18,3 m2
VZ1
VZ4
VZ4
VZ4
VZ4
VZ4
VZ4
VZ4
VZ1
VZ1
VZ1
VZ1
VZ3
VZ3
VZ3
VZ1
VZ1
VZ3
VZ4
VZ4
VZ4
VZ4
XXII
C
IV
TLOCRT II KATA
555
O=29,2 m
90
200
90
200
O=29,6 m
NOVA PVC STOLARIJA
LEGENDA
XXIII
XXIII XXIII XXIII
XXIII
XXIII
XXIIIXXIII
TLOCRT KROVNIH PLOHA
LIST BROJ 15
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
TLOCRT KROVNIH PLOHA
NOVO STANJE
5069
1339
1339
3222
5035
615
01990
3222
P=277,2 m2
NEPROHODNI RAVNI KROV
585
20
20 488 20 473 20 3490 20 480 25
443
2687
NOVO STANJE
240
42
179
80
179
80
268
265
273
240
20
265
16
245
800
Cem. glazura 3 cm
Vinaz
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
PRESJEK A-A
Cem. glazura 3 cm
Vinaz
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
LIST BROJ 16
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK A-A
14
Beton u padu 4-9 cm
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
VZ4
VZ4
VZ1
S3
S1
P1
P2
P2
KK1
RK1
RK1
P2
S1
P1
Cem. glazura 3 cm
Epoxy lijevani pod
S
KK1
Izolirani krovni panel
U= 0,18 W/m2K
FPO membrana KAO Sarnafil TS 77 d=1,5mm
SIKATHERM PIR GT d =12 cm
Parna brana KAO Sika BituSeal T-230 PA
800
tribine
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
PRESJEK B-B
LIST BROJ 17
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK B-B
VZ4
S1
P1
P2
RK1
P1
KK1
RK1
NOVO STANJE
Izolirani krovni panel
U= 0,18 W/m2K
Cem. glazura 3 cm
Vinaz
S1
800
800
KK1KK1
Beton u padu 4-9 cm
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
FPO membrana KAO Sarnafil TS 77 d=1,5mm
SIKATHERM PIR GT d =12 cm
Parna brana KAO Sika BituSeal T-230 PA
P2
Cem. glazura 5 cm
Beton 5 cm
Hidroizolacija
Bet. podloga 10 cm
328
116
342
16
278
14
50
800
tribine
800
tribine
Hidroizolacija
Parket 6/2,4
Daske 10/2,4 cm
Bet. podloga
Bet. podloga 10 cm
Daske 10/2,4 cm x2
Drveni el. 10/10/2,4
PRESJEK C-C
LIST BROJ 18
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJEK C-C
VZ4
P1
P2
S1
KK1
RK1
P2 P1
NOVO STANJE
KK1
RK1
Izolirani krovni panel
U= 0,18 W/m2K
Cem. glazura 5 cm
Beton 5 cm
Hidroizolacija
Bet. podloga 10 cm
KK1
RK1
U= 0,18 W/m2K
Cem. glazura 3 cm
Vinaz
S1
tribine
1
1
3
3
tribine
450
300
Mineralna vuna 5 cm
Daska 2,4 cm
Zrak
VZ2
KK1
1
3
7
5
578
50
39
45
Beton u padu 4-9 cm
Hladni bitumen
Beton u padu 4-9 cm
Hladni bitumen
FPO membrana KAO Sarnafil TS 77 d=1,5mm
SIKATHERM PIR GT d =12 cm
Parna brana KAO Sika BituSeal T-230 PA
25
10
PRESJEK D-D
100
20
10350
20
65
170
90
PRESJEK E-E PRESJEK F-F
LIST BROJ 19
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
PRESJECI KROZ SPOJNI HODNIK
PRESJECI KROZ SPOJNI HODNIK
VZ5VZ5
VZ5
P3
P3
RK2
RK2
NOVO STANJE
P3
Hladni bitumenHladni bitumen
Cem. glazura 5 cm
Beton 5 cm
Hidroizolacija
Bet. podloga 10 cm
RK2
Hladni bitumen
Beton u padu 4-9 cm
Bit. ljepenka
Hladni bitumen
Armirani beton 6 cm
Mineralna vuna 16 cm
100
55
210
110
20
320
20
100
260
20
10320
20
60
170
90
40
VZ5VZ5
P3
RK2
Pe folija
F
O
F
O
F
O
F
O
F
O
ZAPADNA FASADA
LIST BROJ 20
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
NOVA PVC STOLARIJA
LEGENDA
O
SJEVERNA FASADA
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
LIST BROJ 21
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
NOVA PVC STOLARIJA
LEGENDA
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
LIST BROJ 22
GL.PROJEKTANT
DIREKTOR
PROJEKTANT
INVESTITOR
GLAVNI PROJEKT
1:100
60/2016., PROSINAC 2016.
ELABORAT
MJERILO
LOKACIJA
BROJ T.D.
FASADE
SJEVERNA FASADA
LEGENDA
SHEMA STOLARIJE
240
233
dvokrilna zaokretna puna vrata
III
KOM 1233/240
LIST BROJ 23
F
dvoja dvokrilna zaokretna ostakljena vrata
dva fiksna polja
470/342
IV
KOM 1
F
210
470
F
F
FFF
F
62
272
LIST BROJ 24
472,5/80+ 82 cm
VII
KOM 1
sa ispunom gornjih polja. Sva donja krila otklopna.
180
80
260
95
75,5 75,5 75,5 75,5 75,5
342
82
82
LIST BROJ 25
staklena stijena - sastoji se od
120/240 cm
VIII
KOM 3
jednog zaokretno-otklopnog i jednog fiksnog krila
F
120
20
100
120
240
LIST BROJ 26
Jednokrilni prozor krilo na krilo
120/120 cm
XI
KOM 1
krilo otklopno
O
120
120
240
120
LIST BROJ 27
91 96 90
277
190
50
240
Trokrilni prozor krilo na krilo
277/50 cm
XII
KOM 1
Sva krila otklopna
LIST BROJ 28
100
190
50
240
jednokrilni otklopni prozor
100/50 cm
XIII
KOM 1
LIST BROJ 29
419/50
XVI
KOM 2
50
419,5
LIST BROJ 30
staklena stijena - sastoji se od
100/240 cm
XVII
KOM 3
jednog otklopnog i jednog fiksnog krila, krilo na krilo
F
100
20
90
130
240
LIST BROJ 31
120
50
jednokrilni prozor krilo na krilo
120/50 cm
XVIII
KOM 2
Krilo otklopno
LIST BROJ 32
120
110
jednokrilni prozor krilo na krilo
120/50 cm
XIX
KOM 1
Krilo otklopno i zaokretno
LIST BROJ 33
120
110
jednokrilni prozor krilo na krilo
120/50 cm
XX
KOM 11
Krilo otklopno i zaokretno
O
LIST BROJ 34
staklena stijena koja se sastoji od
470/300
XXI
5 otklopnih krila, 10 fiksnih ostakljenih polja
F F F F F
94 94 94 94 94
470
300
KOM 7
F F F F F
LIST BROJ 35
staklena stijena koja se sastoji od
563/179 cm
XXII
10 fiksnih krila
KOM 2
F F F F F
F F F F F
112,6 112,6 112,6 112,6 112,6
563
70
109
179
LIST BROJ 36
LIST BROJ 37
XXIII
KOM 8
475/80 cm
Sva krila otklopna
475
80
T-PROJEKT d.o.o. Čazma Str.17
D. PRORAČUN ENERGETSKIH POTREBA
DVORANA ČAZMA - POSTOJEĆE
Projektantska tvrtka: T-PROJEKT D.O.O.
Investitor: OSNOVNA ŠKOLA ČAZMA
Građevina: ŠKOLSKA SPORTSKA DVORANA
Lokacija: ČAZMA
Broj projekta: 60/2016
Broj mape:
Glavni projektant: RAJKA TORBAŠINOVIĆ ING.ARH.
Projektant: RAJKA TORBAŠINOVIĆ ING. ARH.
Projektant uštede energije i toplinske zaštite: RAJKA TORBAŠINOVIĆ ING. ARH.
Datum izrade: 12.1.2018.
Obrazac 1, list 1/4
ISKAZNICA ENERGETSKIH SVOJSTAVA ZGRADE
prema poglavlju VI. Tehničkog propisa o racionalnoj uporabi energije i toplinskoj zaštiti u zgradama, za zgradu grijanu na temperaturu 18 °C ili višu
1. INVESTITOR OSNOVNA ŠKOLA ČAZMA
2. OZNAKA PROJEKTA 60/2016
3. OPIS ZGRADE
Naziv zgrade ili dijela zgrade Zona 2
Lokacija zgrade (katastarska čestica, katastarska općina, naselje s poštanskim brojem, ulica, kućni broj, nadmorska visina)
K.č.br.: 2625/1 (956), K.o.: ČAZMA ALOJZA VULINCA 22 N.v.: 141,00 m
Mjesec i godina izrade projekta Siječanj 2018. godine
Oplošje grijanog dijela zgrade A (m 2 ) 5190,73
Obujam grijanog dijela zgrade V e (m 3 ) 14873,10
Faktor oblika zgrade f 0 (m -1 ) 0,35
Ploština korisne površine zgrade A K (m 2 ) 3317,22
Način grijanja (lokalno, etažno, centralno, toplansko) Centralno
Prosječna unutarnja projektna temperatura grijanja °C 20,00
Prosječna unutarnja projektna temperatura hlađenja °C 22,00
Meteorološka postaja s nadmorskom visinom Bjelovar (141,00 m n.v.)
Srednja mjesečna temperatura vanjskog zraka najhladnijeg mjeseca na lokaciji zgrade Θ e,mj,min (°C)
0,50
Srednje mjesečna temperatura vanjskog zraka najtoplijeg mjeseca na lokaciji zgrade Θ e,mj,max (°C)
22,10
Obrazac 1, list 2/4
4. POTREBNA PRIMARNA ENERGIJA, TOPLINSKA ENERGIJA ZA GRIJANJE ZGRADE I IZRAČUNATA
TOPLINSKA ENERGIJA ZA HLAĐENJE
Godišnja potrebna primarna energija za stvarne klimatske podatke E prim [kWh/a]
620106,68
Godišnja potrebna primarna energija po jedinici ploštine korisne površine zgrade za stvarne klimatske podatke E prim [kWh/m
2 a] (za stambene ili nestambene zgrade)
najveća dopuštena izračunata
400,00 186,94
Godišnja potrebna toplinska energija za grijanje za stvarne klimatske podatke Q H,nd [kWh/a]
421518,32
Godišnja potrebna toplinska energija za grijanje po jedinici ploštine korisne površine zgrade, za stvarne klimatske podatke Q'' H,nd [kWh/(m 2 a)] (za stambene ili nestambene zgrade)
najveća dopuštena izračunata
102,44 127,07
Godišnja potrebna toplinska energija za grijanje po jedinici obujma grijanog dijela zgrade, za stvarne klimatske podatke Q' H,nd [kWh/(m 3 a)] (za nestambene zgrade prosječne visine etaže veće od 4,2 m)
najveća dopuštena izračunata
- -
Godišnja potrebna toplinska energija za hlađenje Q C,nd [kWh/a] (za zgrade sa sustavom hlađenja) 57321,41
Godišnja potrebna toplinska energija za hlađenje po jedinici ploštine korisne površine zgrade Q'' C,nd [kWh/(m
2 a)] (za zgrade sa sustavom hlađenja)
najveća dopuštena izračunata
50,00 17,28
Obrazac 1, list 3/4
5. OBNOVLJIVI IZVORI ENERGIJE
POTREBNO ZA OSTVARENJE UVJETA OSTVARENO (%) ISPUNJENO
(DA/NE)
Najmanje 20% ukupne isporučene energije za rad sustava u zgradi podmireno energijom iz obnovljivih izvora energije
0,00 NE
Om
jer energ
ije
iz o
bnovljiv
ih
izvora
energ
ije
i ukupne
is
poru
čene
toplinske
energ
ije
za
grija
nje
, hla
đenje
zgra
de
i pripre
mu
potr
ošne
tople
vode
Najmanje 25% iz sunčeva zračenja
Najmanje 30% iz plinovite biomase
Najmanje 50% iz čvrste biomase
Najmanje 70% iz geotermalne energije
Najmanje 50% iz topline okoline
Najmanje 50% iz kogeneracijskog postrojenja s visokom učinkovitošću
Najmanje 50% opskrbljena iz sustava energetski učinkovitog daljinskog grijanja prema članku 42. stavku 2.
Najmanje 20% niža od dozvoljene godišnje potrebne topline za grijanje po jedinici ploštine korisne površine zgrade Q'' H,nd
Najmanje 4m 2 ugrađenih sunčanih kolektora (vrijedi iznimno za obiteljske kuće)
6. DRUGA ENERGETSKA OBILJEŽJA ZGRADE
Koeficijent transmisijskog toplinskog gubitka po jedinici oplošja grijanog dijela zgrade H' tr,adj [W/(m
2 K]
najveći dopušteni izračunati
0,73 1,14
Koeficijent transmisijskog toplinskog gubitka H tr,adj (W/K) 5895,911
Koeficijent toplinskog gubitka provjetravanjem H Ve,adj (W/K) 5516,54
Ukupni godišnji gubici topline Q l (kWh) 760639,38
Godišnji iskoristivi unutarnji dobici topline Q i (kWh) 174353,23
Godišnji iskoristivi solarni dobici topline Q s (kWh) 116971,87
Ukupni godišnji iskoristivi dobici topline Q g (kWh) 291325,11
Obrazac 1, list 4/4
7. ODGOVORNOST ZA PODATKE
Projektant (ime i prezime / naziv i adresa) T-PROJEKT D.O.O.
Projektant dijela glavnog projekta zgrade koji se odnosi na racionalnu uporabu energije i toplinsku zaštitu (potpis i žig)
RAJKA TORBAŠINOVIĆ ING. ARH.
Glavni projektant zgrade (potpis i žig) RAJKA TORBAŠINOVIĆ ING.ARH.
Datum i pečat projektantske tvrtke 12.1.2018.
Sadržaj Iskaznica potrebne toplinske energije za grijanje i toplinske energije za hlađenje 2
A. Zona 2 - Iskaznica potrebne toplinske energije za grijanje i toplinske energije za hlađenje 2
1. Tehnički opis 7
1.1. Podaci o lokaciji objekta 7
1.2. Namjena zgrade i podjela u toplinske zone 8
1.3. Zona 1 - Zona 2 8
1.3.1. Geometrijske karakteristike zgrade 8
1.3.2. Građevni dijelovi zgrade, slojevi i obrada 8
1.3.3. Otvori (prozirni i neprozirni elementi) zgrade 12
1.3.4. Zaštita od prekomjernog Sunčevog zračenja (ljetni period) 13
1.3.5. Sustav grijanja i energent za grijanje zgrade 13
ZONA 2 14
2.A. Zona 2 - Proračun i ocjena fizikalnih svojstava zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu
14
2.A.1. Proračun građevnih dijelova zgrade 14
2.A.2. Vanjski otvori (HRN EN ISO 10077-1:2000) 30
2.A.3. Proračun toplinskih mostova (HRN EN ISO 14683) 31
2.A.4. Ukupni transmisijski gubici 31
2.A.4.1. Gubici topline kroz vanjski omotač zgrade 31
2.A.4.2. Gubici topline kroz vanjske otvore 32
2.A.4.3. Proračun građevnih dijelova u kontaktu s tlom (HRN EN ISO 13370) 32
2.A.4.3.1. Tablični pregled definiranih gubitaka kroz tlo 32
2.A.4.3.2. Podovi na tlu 33
2.A.4.4. Gubici topline kroz negrijane prostore 33
2.A.4.5. Gubici topline kroz susjedne zgrade 33
2.A.5. Proračun potrebne energije za grijanje i hlađenje (prema HRN EN 13790:2008) 33
2.A.5.1. Toplinski gubici 34
2.A.5.2. Toplinski dobici 36
2.A.5.3. Proračun potrebne topline za grijanje i hlađenje 37
2.A.5.4. Rezultati proračuna 38
2.A.5.5. Proračun potrošnje i cijene energenata 39
2.A.5.6. Proračun godišnje emisije CO 2 39
2.A.5.7. Godišnja primarna energija 39
3. Program kontrole i osiguranja kvalitete 40
4. Nacrti s ucrtanom granicom grijanog dijela zgrade te detalji rješavanja toplinskih mostova 47
5. Primijenjeni propisi i norme 48
1. Tehnički opis
1.1. Podaci o lokaciji objekta Predmetna građevina se nalazi u 2. zoni globalnog Sunčevog zračenja sa srednjom mjesečnom temperaturom vanjskog zraka najhladnijeg mjeseca na lokaciji zgrade Θ e,mj,min ≤ 3
o C i unutarnjom temperaturom Θ i ≥ 18°C. Klimatološki podaci lokacije objekta:
Lokacija: ČAZMA
Referentna postaja: Bjelovar
I II III IV V VI VII VIII IX X XI XII God.
Temperature zraka ( o C)
m 0,5 2,6 7 11,9 17,1 20,6 22,1 21,4 16 11,2 6,2 1 11,5
min -14,3 -10,7 -7,3 0,8 5,3 9,7 13,6 10,8 7,4 -0,4 -6 -13,8 -14,3
max 12 14 18,2 21,3 26,4 30,2 30,1 31,3 25,5 21,2 20,2 14,3 31,3
Tlak vodene pare (Pa)
m 530 600 730 950 1330 1660 1820 1800 1480 1090 800 600 1120
Relativna vlažnost zraka (%)
m 84 75 70 68 68 69 69 72 78 81 84 86 75
Brzina vjetra (m/s)
m 1,6 1,9 2 2,1 2,1 1,9 1,8 1,8 1,8 1,7 1,7 1,6 1,8
Broj dana grijanja
Temperatura vanjskog zraka ≤ 10 o C 165
≤ 12 o C 183,6
≤ 15 o C 202,5
Orij [ o ] I II III IV V VI VII VIII IX X XI XII God.
Globalno Sunčevo zračenje (MJ/m 2 )
S
0 130 190 356 481 590 611 664 573 435 272 131 86 4519
15 165 230 402 507 595 605 663 594 486 327 161 104 4839
30 193 260 429 511 576 576 637 590 513 366 184 118 4953
45 211 276 436 492 535 527 585 560 515 387 198 127 4849
60 219 279 422 452 473 459 512 505 490 388 202 130 4530
75 215 268 387 392 396 378 422 431 442 369 197 126 4020
90 201 243 334 318 308 291 322 341 372 331 182 117 3360
SE, SW
0 130 190 356 481 590 611 664 573 435 272 131 86 4519
15 154 218 389 500 594 607 664 589 472 311 152 99 4747
30 172 237 407 504 580 585 645 587 491 337 166 107 4819
45 182 246 409 489 548 547 606 564 491 348 173 111 4714
60 184 243 393 456 499 492 548 521 469 342 173 111 4431
75 176 229 361 407 435 425 475 461 428 321 164 105 3988
90 161 205 316 346 362 350 392 388 371 286 149 96 3421
E, W
0 130 190 356 481 590 611 664 573 435 272 131 86 4519
15 130 191 355 477 584 604 656 567 434 272 131 86 4485
30 130 189 349 465 565 583 635 552 427 270 130 85 4380
45 127 184 337 445 536 550 601 527 412 264 127 82 4192
60 121 175 317 414 495 506 555 490 389 251 120 78 3911
75 112 161 290 374 443 452 498 442 355 231 110 71 3538
90 99 143 255 327 384 391 431 385 313 205 98 62 3094
NE, NW 0 130 190 356 481 590 611 664 573 435 272 131 86 4519
15 105 160 315 446 568 596 642 538 387 229 109 73 4169
30 89 136 274 402 525 557 595 488 336 193 94 64 3751
45 73 117 241 356 472 503 534 433 293 167 79 57 3324
60 67 92 206 317 419 447 474 385 256 130 70 52 2916
75 61 82 154 265 367 394 416 329 192 106 63 47 2475
90 54 73 126 187 285 315 326 239 137 95 56 40 1931
E, N
0 130 190 356 481 590 611 664 573 435 272 131 86 4519
15 89 143 294 431 556 585 628 522 364 205 95 64 3978
30 78 104 221 362 491 524 555 445 277 139 81 60 3337
45 73 97 167 279 405 439 455 350 189 125 125 57 2713
60 67 90 153 203 306 339 339 246 159 116 70 52 2141
75 61 82 140 182 229 236 235 205 148 106 63 47 1733
90 54 73 126 164 206 213 214 186 135 95 56 40 1562
1.2. Namjena zgrade i podjela u toplinske zone
Namjena zgrade Nestambena zgrada
Podjela zgrade u toplinske zone ne
1.3. Zona 1 - Zona 2
Uvjet Status
Koeficijenti prolaska topline NE ZADOVOLJAVA
Difuzija NE ZADOVOLJAVA
Dinamičke toplinske karakteristike NE ZADOVOLJAVA
Korisna energija NE ZADOVOLJAVA
Isporučena energija ZADOVOLJAVA
Primarna energija ZADOVOLJAVA
1.3.1. Geometrijske karakteristike zgrade
Potrebni podaci Zona 1
Oplošje grijanog dijela zgrade – A [m 2 ] 5190,73
Obujam grijanog dijela zgrade – V e [m 3 ] 14873,10
Obujam grijanog zraka – V [m 3 ] 12031,47
Faktor oblika zgrade - f 0 [m -1 ] 0,35
Ploština korisne površine – A K [m 2 ] 3317,22
Ukupna ploština pročelja – A uk [m 2 ] 3404,25
Ukupna ploština prozora – A wuk [m 2 ] 313,67
1.3.2. Građevni dijelovi zgrade, slojevi i obrada
Definirani slojevi građevnog dijela (u smjeru toplinskog toka) prikazani za građevne dijelove grupirane prema zonama i prema vrsti građevnog dijela.
1.3.2.1 Vanjski zidovi 1 - VZ-1-vanjski zid šuplja opeka
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 1.08 Šuplji blokovi od gline 29,000 0,480 10,00 2,90 1100,00
3 3.03 Vapneno-cementna žbuka 3,000 1,000 20,00 0,60 1800,00
Definirane ploštine [m 2 ]: Istok 215,12
Sjever 212,32
Zapad 139,24
1.3.2.2 Vanjski zidovi 2 - VZ-2- AB stupovi
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 Beton armiran (s 2% čelika) 29,000 2,300 130,00 37,70 2300,00
3 3.03 Vapneno-cementna žbuka 3,000 1,000 20,00 0,60 1800,00
Definirane ploštine [m 2 ]: Istok 33,65
Sjever 34,92
Zapad 26,20
Jug 33,64
1.3.2.3 Vanjski zidovi 3 - VZ-3- sendvič AB + fasadna opeka
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 Beton armiran (s 2% čelika) 16,000 2,300 130,00 20,80 2300,00
3 7.02 Ekspandirani polistiren (EPS) 2,500 0,037 60,00 1,50 21,00
4 1.05 Puna fasadna opeka od gline 12,000 0,830 10,00 1,20 1800,00
Definirane ploštine [m 2 ]: Istok 33,65
Sjever 34,92
Zapad 26,20
Jug 33,64
1.3.2.4 Vanjski zidovi 4 - VZ-4- AB dijelovi zida
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 Beton armiran (s 2% čelika) 29,000 2,300 130,00 37,70 2300,00
3 3.03 Vapneno-cementna žbuka 3,000 1,000 20,00 0,60 1800,00
Definirane ploštine [m 2 ]: Istok 23,30
Sjever 47,75
Zapad 39,22
Jug 76,20
1.3.2.5 Vanjski zidovi 5 - VZ-5-vanjski zid šuplja opeka HODNIK
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 1.08 Šuplji blokovi od gline 29,000 0,480 10,00 2,90 1100,00
3 3.03 Vapneno-cementna žbuka 3,000 1,000 20,00 0,60 1800,00
Definirane ploštine [m 2 ]: Istok 3,89
Sjever 102,66
Zapad 6,84
Jug 95,78
1.3.2.6 Vanjski zidovi 6 - VZ-6- AB dijelovi zida
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.03 Vapneno-cementna žbuka 2,000 1,000 20,00 0,40 1800,00
2 Beton armiran (s 2% čelika) 29,000 2,300 130,00 37,70 2300,00
3 3.03 Vapneno-cementna žbuka 3,000 1,000 20,00 0,60 1800,00
Definirane ploštine [m 2 ]: Istok 0,40
Sjever 9,49
Zapad 0,82
Jug 10,63
1.3.2.7 Podovi na tlu 1 - P1-pod na tlu - dvorana
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 4.05 Drvo - meko - crnogorica 2,400 0,130 50,00 1,20 500,00
2 4.05 Drvo - meko - crnogorica 2,400 0,130 50,00 1,20 500,00
3 Neprovjetravan sloj zraka 4,800 - 1,00 0,01 -
4 4.05 Drvo - meko - crnogorica 2,400 0,130 50,00 1,20 500,00
5 7.01 Mineralna vuna (MW) 2,000 0,032 1,00 0,02 10,00
6 2.01 Armirani beton 10,000 2,600 110,00 11,00 2500,00
7 Bitumenska ljepenka (traka) 1,000 0,230 50000,00 500,00 1100,00
8 2.03 Beton 10,000 2,000 100,00 10,00 2400,00
9 6.04 Pijesak, šljunak, tucanik (drobljenac) 15,000 0,810 3,00 0,45 1700,00
Definirana ploština [m 2 ]: 1104,70
1.3.2.8 Podovi na tlu 2 - P2-pod na tlu - PKP
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 4.03 Keramičke pločice 0,700 1,300 200,00 1,40 2300,00
2 3.18 Cementni mort 2,000 1,600 25,00 0,50 2000,00
3 2.03 Beton 5,000 2,000 100,00 5,00 2400,00
4 Bitumenska ljepenka (traka) 1,000 0,230 50000,00 500,00 1100,00
5 2.03 Beton 10,000 2,000 100,00 10,00 2400,00
6 6.04 Pijesak, šljunak, tucanik (drobljenac) 15,000 0,810 3,00 0,45 1700,00
Definirana ploština [m 2 ]: 275,60
1.3.2.9 Podovi na tlu 3 - P-3 -pod na tlu - HODNIK
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 4.03 Keramičke pločice 0,700 1,300 200,00 1,40 2300,00
2 3.18 Cementni mort 2,000 1,600 25,00 0,50 2000,00
3 2.03 Beton 5,000 2,000 100,00 5,00 2400,00
4 Bitumenska ljepenka (traka) 1,000 0,230 50000,00 500,00 1100,00
5 2.03 Beton 10,000 2,000 100,00 10,00 2400,00
6 6.04 Pijesak, šljunak, tucanik (drobljenac) 10,000 0,810 3,00 0,30 1700,00
Definirana ploština [m 2 ]: 221,90
1.3.2.10 Podovi na tlu 4 - P-4- pod na tlu PKP
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 4.03 Keramičke pločice 0,700 1,300 200,00 1,40 2300,00
2 3.18 Cementni mort 2,000 1,600 25,00 0,50 2000,00
3 2.03 Beton 5,000 2,000 100,00 5,00 2400,00
4 Bitumenska ljepenka (traka) 1,000 0,230 50000,00 500,00 1100,00
5 2.03 Beton 10,000 2,000 100,00 10,00 2400,00
6 6.04 Pijesak, šljunak, tucanik (drobljenac) 15,000 0,810 3,00 0,45 1700,00
Definirana ploština [m 2 ]: 184,28
1.3.2.11 Kosi krovovi iznad grijanog prostora 1 - Kosi krov dvorane
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 4.05 Drvo - meko - crnogorica 1,800 0,130 50,00 0,90 500,00
2 7.01 Mineralna vuna (MW) 5,000 0,032 1,00 0,05 10,00
3 Dobro provjetravan sloj zraka 8,000 - 1,00 0,01 -
4 Nehrđajući čelik 0,060 17,000 900000,00 60,00 7900,00
Definirane ploštine [m 2 ]: Sjever 657,00
Jug 657,00
1.3.2.12 Ravni krovovi iznad grijanog prostora 1 - Ravni krov dvorane
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.02 Vapnena žbuka 2,000 0,800 10,00 0,20 1600,00
2 2.01 Armirani beton 14,000 2,600 110,00 15,40 2500,00
3 2.03 Beton 4,000 2,000 100,00 4,00 2400,00
4 Bitumen čisti 0,200 0,170 50000,00 100,00 1050,00
5 5.01 Bitum. traka s uloškom stakl. voala 0,800 0,230 50000,00 400,00 1100,00
6 7.02 Ekspandirani polistiren (EPS) 5,000 0,037 60,00 3,00 21,00
7 Bitumen čisti 0,200 0,170 50000,00 100,00 1050,00
8 5.01 Bitum. traka s uloškom stakl. voala 0,800 0,230 50000,00 400,00 1100,00
9 Bitumenska ljepenka (traka) 1,000 0,230 50000,00 500,00 1100,00
10 6.04 Pijesak, šljunak, tucanik (drobljenac) 2,000 0,810 3,00 0,06 1700,00
Definirana ploština [m 2 ]: 314,20
1.3.2.13 Ravni krovovi iznad grijanog prostora 2 - Ravni krov hodnika
R.b. Materijal d [cm] λ [W/mK] μ [ - ] sd [m] ρ [kg/m 3 ]
1 3.02 Vapnena žbuka 2,000 0,800 10,00 0,20 1600,00
2 2.01 Armirani beton 14,000 2,600 110,00 15,40 2500,00
3 2.03 Beton 4,000 2,000 100,00 4,00 2400,00
4 Bitumen čisti 0,200 0,170 50000,00 100,00 1050,00
5 5.01 Bitum. traka s uloškom stakl. voala 1,000 0,230 50000,00 500,00 1100,00
6 Dobro provjetravan sloj zraka 10,000 - 1,00 0,01 -
7 Čelik 0,060 50,000 1000000,00 60,00 7800,00
Definirana ploština [m 2 ]: 221,90
Važna napomena: Ukoliko se namjerava iz bilo kojeg razloga mijenjati projektirani toplinsko izolacijski materijal, ugrađeni materijal ne smije biti slabije kvalitete od projektom predviđenog niti po jednom od bitnih parametara (koeficijent toplinske provodljivosti, paropropusnost, klasa gorivosti,..). Za sve ugrađene toplinsko izolacijske materijale moraju se priložiti valjane potvrde, a za one koji ne odgovaraju projektom predviđenim sve potrebne suglasnosti i dokazi da isti ne narušavaju proračunom dokazane vrijednosti.
1.3.3. Otvori (prozirni i neprozirni elementi) zgrade Naziv otvora Uw [W/m 2 K] Orijentacija Aw [m 2 ] n
METALNI PROZOR 5,20 Zapad 1,44 12,00
METALNI FRANCUSKI PROZOR 5,20 Zapad 2,64 4,00
METALNI FRANCUSKI PROZOR 5,20 Zapad 2,40 2,00
PVC ostakljena vrata 1,40 Zapad 7,40 1,00
METALNA OSTAKLJENA STIJENA 5,20 Zapad 5,30 1,00
METALNI PROZOR 5,20 Jug 1,30 1,00
METALNI FRANCUSKI PROZOR 5,20 Istok 2,40 2,00
METALNI PROZOR 5,20 Sjever 14,10 7,00
VANJSKA METALNA VRATA 5,20 Sjever 5,47 1,00
METALNI PROZOR 5,20 Sjever 2,10 2,00
METALNI PROZOR 5,20 Jug 0,50 2,00
METALNI PROZOR 5,20 Jug 7,69 1,00
METALNI PROZOR 5,20 Jug 3,80 4,00
PVC PROZOR 1,40 Jug 3,80 4,00
PVC PROZOR 1,40 Jug 4,00 4,00
PVC VRATA 1,40 Zapad 2,10 1,00
1,40 Sjever 2,10 1,00
PVC PROZOR 1,40 Sjever 1,36 8,00
1,40 Jug 1,36 22,00
VANJSKA METALNA VRATA 5,20 Jug 7,27 1,00
VANJSKA METALNA VRATA 5,20 Jug 16,10 1,00
METALNI PROZOR 5,20 Jug 3,80 8,00
1.3.4. Zaštita od prekomjernog Sunčevog zračenja (ljetni period)
Nema definiranih prostorija!
1.3.5. Sustav grijanja i energent za grijanje Sustav grijanja: Centralno Grijanje s prekidima ili podešenom nižom temperaturom: Stalno grijanje Udio vremena s definiranom unutarnjom temperaturom – f H,hr (režim rada termotehničkog sustava za grijanje):
0,61
Omjer dana u tjednu s definiranom unutarnjom temperaturom (za hlađenje) – f C,day :
0,71
Vrsta energenta za grijanje: Prirodni plin Vrsta i način korištenja obnovljivih izvora energije: Udio obnovljive energije u isporučenoj energiji [%]: 0,00
ZONA 2
2.A. Proračun i ocjena fizikalnih svojstava zgrade u odnosu na racionalnu uporabu energije i toplinsku zaštitu
Unutarnja projektna temperatura grijanja: 18,00 °C
2.A.1. Proračun građevnih dijelova zgrade
Naziv građevnog dijela A [m 2 ] U [W/m 2 K] U max [W/m 2 K] OK
VZ-1-vanjski zid šuplja opeka 566,68 1,21 0,30
VZ-2- AB stupovi 128,41 2,89 0,30
VZ-3- sendvič AB + fasadna opeka 128,41 0,93 0,30
VZ-4- AB dijelovi zida 186,47 2,89 0,30
VZ-5-vanjski zid šuplja opeka HODNIK 209,17 1,21 0,30
VZ-6- AB dijelovi zida 21,34 2,89 0,30
P1-pod na tlu - dvorana 1104,70 0,53 0,40
P2-pod na tlu - PKP 275,60 2,03 0,40
P-3 -pod na tlu - HODNIK 221,90 2,33 0,40
P-4- pod na tlu PKP 184,28 2,03 0,40
Kosi krov dvorane 1314,00 0,53 0,25
Ravni krov dvorane 314,20 0,57 0,25
Ravni krov hodnika 221,90 2,82 0,25
2.A.1.1. Vanjski zidovi 1 - VZ-1-vanjski zid šuplja opeka Opći podaci o građevnom dijelu
A gd [m 2 ] A I A Z A S A J A SI A SZ A JI A JZ
566,68 215,12 139,24 212,32 0,00 0,00 0,00 0,00 0,00
Toplinska zaštita: U [W/m 2 K] = 1,21 ≤ 0,30 NE ZADOVOLJAVA
Površinska vlažnost: (Rizik okruženja s plijesni φ Si ≤ 0,8)
fRsi = 0,85 ≥ 0,70 NE ZADOVOLJAVA
Unutarnja kondenzacija: ΣM a,god = 0,00 ZADOVOLJAVA
Dinamičke karakteristike: 409,00 ≥ 100 kg/m 2
U = 1,21 ≤ 0,30 NE ZADOVOLJAVA
Slojevi građevnog dijela u smjeru toplinskog toka d[cm] ρ[kg/m 3 ] λ[W/mK] R[m 2 K/W]
1 3.03 Vapneno-cementna žbuka 2,000 1800,00 1,000 0,020 2 1.08 Šuplji blokovi od gline 29,000 1100,00 0,480 0,604 3 3.03 Vapneno-cementna žbuka 3,000 1800,00 1,000 0,030
R si = 0,130
R se = 0,040
R T = 0,824 U pogledu toplinske zaštite, građevni dio s U [W/m 2 K] = 1,21 U = 1,21 ≥ U max = 0,30 NE ZADOVOLJAVA
Plošna masa građevnog dijela 409,00 [kg/m2] 409,00 ≥ 100 kg/m 2
U = 1,21 ≤ 0,30 NE ZADOVOLJAVA
Ispravci i dodaci
Zračne šupljine (HRN EN ISO 6946, Annex E) Tip zračnih šupljina: Nema zračnih šupljina koje prodiru kroz cijeli izolacijski sloj
Proračun najveće dozvoljene površinske vlažnosti (HRN EN ISO 13788) Odabrani način proračuna površinske vlažnosti: Primjena razreda vlažnosti u prostoriji - neklimatizirana zgrada
Odabrani razred vlažnosti: Stambene prostorije s malim intenzitetom korištenja
Unutarnja temperatura grijanja uz građevni dio: θ int,set,H,gd = 18,00°C
Siječanj 0,5 0,84 532 790 1401 1751 15,4 18,0 0,85
Veljača 2,6 0,75 552 705 1327 1659 14,6 18,0 0,78
Ožujak 7,0 0,70 701 527 1280 1600 14,0 18,0 0,64
Travanj 11,9 0,68 947 328 1308 1635 14,4 18,0 0,40
Svibanj 17,1 0,68 1325 117 1454 1818 16,0 18,0 0,00
Lipanj 20,6 0,69 1673 0 1673 2092 18,2 18,0 0,00
Srpanj 22,1 0,69 1834 0 1834 2293 19,7 18,0 0,59
Kolovoz 21,4 0,72 1834 0 1834 2293 19,7 18,0 0,50
Rujan 16,0 0,78 1417 162 1596 1995 17,5 18,0 0,73
Listopad 11,2 0,81 1077 356 1469 1836 16,2 18,0 0,73
Studeni 6,2 0,84 796 559 1411 1764 15,5 18,0 0,79
Prosinac 1,0 0,86 564 770 1411 1764 15,5 18,0 0,85
Površinska vlažnost fR si = 0,85 ≥ fR si, max = 0,70 NE ZADOVOLJAVA
Kritični mjeseci: , prosinac
Ocjena opasnosti od kondenzacije na okvirima otvora koji se nalaze na ovom građevnom dijelu
Naziv otvora fRsi fRsi,max Θ min OK
METALNI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI FRANCUSKI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI FRANCUSKI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
PVC ostakljena vrata 0,82 0,85 -9,9 NE ZADOVOLJAVA
METALNA OSTAKLJENA STIJENA 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI FRANCUSKI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
VANJSKA METALNA VRATA 0,32 0,85 -9,9 NE ZADOVOLJAVA
METALNI PROZOR 0,32 0,85 -9,9 NE ZADOVOLJAVA
PVC VRATA 0,82 0,85 -9,9 NE ZADOVOLJAVA
Mjesečni proračun kondenzacije i akumulacije vlage
Mjesec g c1 M a1
Siječanj - Prosinac 0,00000 0,00000
U pogledu kondenzacije građevni dio: ZADOVOLJAVA
2.A.1.2. Vanjski zidovi 2 - VZ-2- AB stupovi
Opći podaci o građevnom dijelu
A gd [m 2 ] A I A Z A S A J A SI A SZ A JI A JZ
128,41 33,65 26,20 34,92 33,64 0,00 0,00 0,00 0,00
Toplinska zaštita: U [W/m 2 K] = 2,89 ≤ 0,30 NE ZADOVOLJAVA
Površinska vlažnost: (Rizik okruženja s plijesni φ Si ≤ 0,8)
fRsi = 0,85 ≥ 0,28 NE ZADOVOLJAVA
Unutarnja kondenzacija: ΣM a,god = 0 NE ZADOVOLJAVA
Dinamičke karakteristike: 757,00 ≥ 100 kg/m 2
U = 2,89 ≤ 0,30 NE ZADOVOLJAVA
Slojevi građevnog dijela u smjeru toplinskog toka d[cm] ρ[kg/m 3 ] λ[W/mK] R[m 2 K/W]
1 3.03 Vapneno-cementna žbuka 2,000 1800,00 1,000 0,020 2 Beton armiran (s 2% čelika) 29,000 2300,00 2,300 0,126 3 3.03 Vapneno-cementna žbuka 3,000 1800,00 1,000 0,030
R si = 0,130
R se = 0,040
R T = 0,346
U pogledu toplinske zaštite, građevni dio s U [W/m 2 K] = 2,89 U = 2,89 ≥ U max = 0,30 NE ZADOVOLJAVA
Plošna masa građevnog dijela 757,00 [kg/m2] 757,00 ≥ 100 kg/m 2
U = 2,89 ≤ 0,30 NE ZADOVOLJAVA
Ispravci i dodaci
Zračne šupljine (HRN EN ISO 6946, Annex E) Tip zračnih šupljina: Nema zračnih šupljina koje prodiru kroz cijeli izolacijski sloj
Proračun najveće dozvoljene površinske vlažnosti (HRN EN ISO 13788) Odabrani način proračuna površinske vlažnosti: Primjena razreda vlažnosti u prostoriji - neklimatizirana zgrada
Odabrani razred vlažnosti: Stambene prostorije s malim intenzitetom korištenja
Unutarnja temperatura grijanja uz građevni dio: θ int,set,H,gd = 18,00°C
Siječanj 0,5 0,84 532 790 1401 1751 15,4 18,0 0,85
Veljača 2,6 0,75 552 705 1327 1659 14,6 18,0 0,78
Ožujak 7,0 0,70 701 527 1280 1600 14,0 18,0 0,64
Travanj 11,9 0,68 947 328 1308 1635 14,4 18,0 0,40
Svibanj 17,1 0,68 1325 117 1454 1818 16,0 18,0 0,00
Lipanj 20,6 0,69 1673 0 1673 2092 18,2 18,0 0,00
Srpanj 22,1 0,69 1834 0 1834 2293 19,7 18,0 0,59
Kolovoz 21,4 0,72 1834 0 1834 2293 19,7 18,0 0,50
Rujan 16,0 0,78 1417 162 1596 1995 17,5 18,0 0,73
Listopad 11,2 0,81 1077 356 1469 1836 16,2 18,0 0,73
Studeni 6,2 0,84 796 559 1411 1764 15,5 18,0 0,79
Prosinac 1,0 0,86 564 770 1411 1764 15,5 18,0 0,85
Površinska vlažnost fR si = 0,85 ≥ fR si, max = 0,28 NE ZADOVOLJAVA
Kritični mjeseci: , prosinac
Mjesečni proračun kondenzacije i akumulacije vlage
Mjesec g c1 M a1
Studeni 0,10220 0,10220
Prosinac 0,43144 0,53364
Siječanj 0,44564 0,97928
Veljača 0,20251 1,18179
Ožujak -0,12676 1,05503
Travanj -0,44869 0,60634
Svibanj -0,73481 0,00000
Lipanj Srpanj Kolovoz Rujan Listopad U pogledu kondenzacije građevni dio: NE ZADOVOLJAVA
2.A.1.3. Vanjski zidovi 3 - VZ-3- sendvič AB + fasadna opeka Opći podaci o građevnom dijelu
A gd [m 2 ] A I A Z A S A J A SI A SZ A JI A JZ
128,41 33,65 26,20 34,92 33,64 0,00 0,00 0,00 0,00
Toplinska zaštita: U [W/m 2 K] = 0,93 ≤ 0,30 NE ZADOVOLJAVA
Površinska vlažnost: (Rizik okruženja s plijesni φ Si ≤ 0,8)
fRsi = 0,85 ≥ 0,77 NE ZADOVOLJAVA
Unutarnja kondenzacija: ΣM a,god = 0,00 ZADOVOLJAVA
Dinamičke karakteristike: 620,53 ≥ 100 kg/m 2
U = 0,93 ≤ 0,30 NE ZADOVOLJAVA
Slojevi građevnog dijela u smjeru toplinskog toka d[cm] ρ[kg/m 3 ] λ[W/mK] R[m 2 K/W]
1 3.03 Vapneno-cementna žbuka 2,000 1800,00 1,000 0,020 2 Beton armiran (s 2% čelika) 16,000 2300,00 2,300 0,070
3 7.02 Ekspandirani polistiren (EPS) 2,500 21,00 0,037 0,676 4 1.05 Puna fasadna opeka od gline 12,000 1800,00 0,830 0,145
R si = 0,130
R se = 0,040
R T = 1,080 U pogledu toplinske zaštite, građevni dio s U [W/m 2 K] = 0,93 U = 0,93 ≥ U max = 0,30 NE ZADOVOLJAVA
Plošna masa građevnog dijela 620,53 [kg/m2] 620,53 ≥ 100 kg/m 2
U = 0,93 ≤ 0,30 NE ZADOVOLJAVA
Ispravci i dodaci
Zračne šupljine (HRN EN ISO 6946, Annex E) Tip zračnih šupljina: Nema zračnih šupljina koje prodiru kroz cijeli izolacijski sloj
Proračun najveće dozvoljene površinske vl