9
Dietrich Baade & ODT: Optical Detector Systems at ESO 1 Optical Detector Systems at the European Southern Observatory Dietrich Baade & Optical Detector Team (ODT) Work at ESO on infrared detectors covered in: Dorn et al. Finger et al. Mehrgan et al. Beletic et al.

Optical Detector Systems at the European Southern Observatory

Embed Size (px)

DESCRIPTION

Optical Detector Systems at the European Southern Observatory. Dietrich Baade & Optical Detector Team (ODT). Work at ESO on infrared detectors covered in:. Dorn et al. Finger et al. Mehrgan et al. Beletic et al. The ODT Themes. VLT 2 nd generation instruments:. - PowerPoint PPT Presentation

Citation preview

Dietrich Baade & ODT: Optical Detector Systems at ESO

1

Optical Detector Systems at the

European Southern ObservatoryDietrich Baade

&Optical Detector Team (ODT)

Work at ESO on infrared detectors covered in:

Dorn et al. Finger et al. Mehrgan et al. Beletic et al.

Dietrich Baade & ODT: Optical Detector Systems at ESO

2

The ODT Themes

• Shift in emphasis from scientific imaging to signal sensing: Without AO, ELTs will not bring any improvement.

• The MAD adaptive optics system tests enabling technology with bright natural guide stars.

• The OPTICON project with e2v L3 Vision technology aims to push this towards the ultra-low noise domain.

• The New General detector Controller (NGC) is a key stepping stone.

• More to come

VLT 2nd generation instruments:• X-shooter – the 0.3-to-2.4 μm rapid-response spectro-cannon• MUSE – the cosmic inventory taker

VLT projects in their own right but with an additional view of getting ready for OWL:

OmegaCAM for the VLT Survey Telescope (VST)

Dietrich Baade & ODT: Optical Detector Systems at ESO

3

Multi-conjugated Adaptive Optics Demonstrator

• MAD tests two wavefront-sensing (WFS) concepts:

Reiss et al.

o star oriented, using multiple Shack-Hartmann (SH) systemso layer oriented (LO), using multiple pyramids

• 3 SHWFS + 2 LOWFS detector systems with e2v CCD39 devices (80 x 80 pixels)• Only one method used at a time• One FIERA controller• Up to 400 frames/s (500 frames/s with 2x2 binning)• Considerably exceeds original FIERA spec of 1 Mpixel/s • Read noise: ~7 e-

Dietrich Baade & ODT: Optical Detector Systems at ESO

4

Next-generation Wavefront Sensing: OPTICON and e2v L3 Vision Technology

AO systems for 2nd-gen. VLT instruments and OWL require:• >1,000 actuators (→ >1,000 x 6x6 pixels)• ~1 kHz frame rate• negligible read noise even when photon noise ~100%• high movability (→ no real cryogenics → dark current) OPTICON project received funding from EU Commission CCD220 being developed by e2v

1 system foreseen for HAWK-I, 4 for MUSE

Downing et al.

StoreArea

Image Area

240x12024□µm

StoreArea

Image Area

240x12024□µm

OP 1

OP 2 GainRegisters

OP 3

OP 4 GainRegisters

OP 8GainRegisters

OP 7

OP 6GainRegisters

OP 5

StoreAreaStoreArea

Image Area

240x12024□µm

StoreArea

Image Area

240x12024□µm

OP 1OP 1

OP 2 GainRegisters

OP 2 GainRegisters

OP 3OP 3

OP 4 GainRegisters

OP 4 GainRegisters

OP 8GainRegisters

OP 8GainRegisters

OP 7OP 7

OP 6GainRegisters

OP 6GainRegisters

OP 5OP 5

Dietrich Baade & ODT: Optical Detector Systems at ESO

5

OmegaCAM (1° x 1° imager)

• Three FIERAs and 32 (+4) e2v CCD44-82 devices

• Very robust since first switch-on

• The coordination of autoguiding, closed-loop wavefront sensing, and shutter control is one of the show pieces.

• Built as designed

• Commissioning in 2006

• Strict attention to safety

• Extensive detector characterization on ESO’s test bench

• Innovative cooling system very effective

Iwert et al.

Lizon et al.

Christen et al. (2x)

Dietrich Baade & ODT: Optical Detector Systems at ESO

6

X-shooter

• Basically a single-mode VLT Cassegrain instrument for singular events (`point and shoot´)

• Simultaneous wavelength coverage 0.3 – 2.4 μm• First ESO instrument to bridge the 1-micron barrier• 2 optical arms (e2v CCD44-82 and MIT/LL CCID-20)• 1 IR arm (Rockwell Hawaii-2 RG)

• 1 IRACE and 1 FIERA controller each• FIERA software defines 2 fully independent virtual cameras on one common DFE• Approaching Final Design Review• Commissioning in 2008

Dietrich Baade & ODT: Optical Detector Systems at ESO

7

• First optical instrument to use NGC

• 2nd-generation cryostat head

• Prototype detector system at the end of 2006

Multi-unit Spectroscopic Explorer (MUSE)

• Twenty-four separate detector systems

• 4K x 4K CCDs (or 2 x 1 mosaics)

• 465 – 930 nm: high red response is mission critical

• Need to save mass and volume

• Must ease AIT

• Reliability will be vital

Reiss et al.

Dietrich Baade & ODT: Optical Detector Systems at ESO

8

PULPO2 housekeeping unit with enhanced • shutter ( ) and temperature control• temperature and pressure monitoring

Cryostat Cleanliness and Control

Plasma cleaning: • fast, effective, low risk, low operating cost• excellent results with big OmegaCAM cryostat

Deiries et al.

Geimer et al.

H20 exorcism• baking of CCDs in gas stream • accidental (re-)discovery

Reif et al.

Dietrich Baade & ODT: Optical Detector Systems at ESO

9

New General detector Controller (NGC)

• In the decade since 1998, a total of 30 FIERA and IRACE systems will be deployed.

• Extremely successful (nearly negligible telescope downtime) but some other limitations:

Meyer et al. Cumani et al.

• mass, volume, power dissipation

• obsolete components

• voltage range and swing

• speed, number of channels

• 2 successes (= 2 costs)

Reyes et al.

a

• Proto-type of joint successor NGC has seen `first light´• First deployments: KMOS (2009) and MUSE (2011)