12
HIGH BANDWIDTH HIGH BANDWIDTH Solving Interconnect Problems Quickly Since 1966 Design Through Manufacture of High-Performance-Interconnect Systems, Connectors & Cable Assemblies NX | Mini-SAS | QSFP+ | SFP+ Innovative-Interconnect Solutions High Bandwidth Brochure.pdf Members High Bandwidth

NX | Mini-SAS | QSFP+ | SFP+...CX4 3.125 Gb/s 24 AWG IB SDR 2.5 Gb/s IB DDR* 5.0 Gb/s IB QDR 10.0 Gb/s CX4 3.125 Gb/s Meritec High Performance 4X (SFF-8470) Cable Assemblies Data Rate

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

  • HIGH BANDWIDTHHIGH BANDWIDTH

    HIGH BANDWIDTHHIGH BANDWIDTH

    Solving Interconnect Problems Quickly Since 1966

    Design Through Manufacture of High-Performance-Interconnect Systems,Connectors & Cable Assemblies

    Innovative-Interconnect Solutions

    NX | Mini-SAS | QSFP+ | SFP+

    Innovative-Interconnect Solutions

    Command+Shift Click to Override Master Object> Edit QR Code… paste PDF URL from WordPress Media Panel. Override Product Name and PDF Document Type for each QR. Use Adobe PDF Preset “QR wName Layer” to export just that page number. High Bandwidth Brochure.pdf

    Members

    High Bandwidth

    http://meritec.com/wp-content/uploads/2015/02/MERITEC-New-HBW-NX-Mini-SAS-QSFP-SFP-4-12XDataRates-1409.pdf

  • S2

    S1

    S16

    S15P1

    S2

    S1

    S16

    S15P2

    [14.2].56

    [8.7].34

    [24.7].97

    [7.0].28

    [46.6]1.84

    [8.7].34

    [9.7].38[14.3]

    .56

    [29.7]1.17

    [6.7].26

    [42.8]1.69

    Latch Actuator

    Length

    M2.5 Thumbscrew

    4X & 12XDirect

    Attach

    Direct Attach

    Wafer-Based Design

    Meritec’s 4X (SFF-8470) Direct AttachUL Listed Materials & RoHS Compliant

    See page 7 for more configurations

    Features & Benefits

    • Available in 24, 26, 28 & 30 AWG• Optional connectors available• Supports data rates in excess of 6.0 Gb/s• Meets or exceeds SAS, InfiniBand,

    Ethernet CX4 & SATA specs• Matched impedance design of

    100 Ohm ± 10%

    • Mated cycles: 250 Minimum• Fully electrically tested• Available lengths built to order• LSZH jacketed cable• Durable SFF-8470 design

    Wiring DiagramPlug 1 Plug 2

    S1 S16S2 S15S3 S14S4 S13S5 S12S6 S11S7 S10S8 S9S9 S8S10 S7S11 S6S12 S5S13 S4S14 S3S15 S2S16 S1

    2 High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ www.meritec.com

    888-MERITEC (637-4832)

  • S2

    S1

    S48

    S47P1

    S2

    S1

    S48

    S47P2

    [14.7].58

    [8.7].34

    [49.0]1.93

    [6.9].27

    [48.2]1.90

    [8.7].34

    [9.7].38

    [14.3].56

    [53.6]2.11

    [6.9].27

    [48.5]1.91

    Latch Actuator

    Length

    M2.5 Thumbscrew

    See page 7 for more configurations

    Contact Meritec for more information about custom orders or to ask about your technical needs.

    Specifications

    • Contact Material: Copper Alloy• Standard Contact Finish: 30

    micro" Au / 50 micro" Ni• Die-Cast Shell with Ni Plating• Durability: 250 cycles

    Meritec’s 12X (SFF-8470) Direct AttachUL Listed Materials & RoHS Compliant

    Environmental Specs

    • UL Listed materials• Temperature rating:

    –20 °C to +75 °C• RoHS Compliant

    Wiring DiagramPlug 1 Plug 2

    S1 S48S2 S47S3 S46S4 S45S5 S44S6 S43S7 S42S8 S41S9 S40S10 S39S11 S38S12 S37

    Wiring DiagramPlug 1 Plug 2

    S13 S36S14 S35S15 S34S16 S33S17 S32S18 S31S19 S30S20 S29S21 S28S22 S27S23 S26S24 S25

    Wiring DiagramPlug 1 Plug 2

    S25 S24S26 S23S27 S22S28 S21S29 S20S30 S19S31 S18S32 S17S33 S16S34 S15S35 S14S36 S13

    Wiring DiagramPlug 1 Plug 2

    S37 S12S38 S11S39 S10S40 S9S41 S8S42 S7S43 S6S44 S5S45 S4S46 S3S47 S2S48 S1

    888-MERITEC (637-4832) High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ 3

    www.meritec.com

  • 4 High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ www.meritec.com

    888-MERITEC (637-4832)

    IB refers to InfiniBand™ Trade Association Specification / CX4 refers to the 10GBase Ethernet-CS4 Specification.

    * The InfiniBand DDR lengths for each gauge are based on Meritec’s testing with a Qlogic/Silverstorm 24-Port Switch P/N 9024-CU24-ST2-DDR using the outermost (worst-case) mezzanine ports (top row, extreme left and right-hand)

    MERITEC • 1359 WEST JACKSON STREET • PAINESVILLE, OHIO 44077 USAPHONE: (440) 354-2100 | FAX: (440) 354-5692© Meritec 101203

    Length, Meters – > 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 10 11 12 13 14 15 16 17 18 19 20 21 18 19 20 2130 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    28 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    26 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    24 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    Meritec High Performance 4X (SFF-8470) Cable AssembliesData Rate – Wire Gauge vs. Performance Over Length

    Length, Meters – > 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 10 11 12 13 14 15 16 17 18 19 20 21 18 19 20 2130 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    28 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    26 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    24 AWGIB SDR 2.5 Gb/sIB DDR* 5.0 Gb/sIB QDR 10.0 Gb/s

    CX4 3.125 Gb/s

    Meritec High Performance 4X (SFF-8470) Cable AssembliesData Rate – Wire Gauge vs. Performance Over Length

  • 4X | 12XAssembly

    Description

    Retention Mechanism1 = Latch Retention2 = Thumbscrew Retention

    Retention Mechanism1 = Latch Retention2 = Thumbscrew Retention

    Connector 1 (left)6 = 4X7 = 12X (Not Available in Z Axis or angled configuration)

    Cable Egress1 = Straight2 = Angled3 = Z Axis4 = Belly to Belly

    Cable Egress1 = Straight2 = Angled3 = Z Axis4 = Belly to Belly

    Wire Style and AWG1 = 24 AWG (LSZH)2 = 26 AWG (LSZH)3 = 28 AWG (LSZH)4 = 30 AWG (LSZH)5 = 24 AWG (PVC)6 = 26 AWG (PVC)7 = 28 AWG (PVC)

    Connector 1 (left) Orientation(See “Mech.Orient” sheet)Select one: A,C,E,G,I,K,M,O,S,W,Y

    Connector 2 (right) Orientation(See “Mech.Orient” sheet)Select one: B,D,F,H,J,L,N,P,T,X,Z

    Length00.5 = .5 meters 01.0 = 1 meter 10.0 = 10 meters

    Note: Assembly Description shown above to be used for RFQs and ordering purposes. For application specific assemblies not shown in the table, please contact factory. This is not a part number.

    Connector 2 (right)6 = 4X7 = 12X (Not available in Z Axis or angled configuration)

    Please show below any specific labeling requirements. Default labeling includes: Meritec, P/N, and Date Code.

    7 3 A 2 4 7 5 D 1 10.0

    888-MERITEC (637-4832) High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ 5

    www.meritec.com

  • Z A

    xis

    Cab

    le E

    gres

    s

    Mechanical Orientation LettersLeft End Right End

    Any available “Left End” can be paired with any available “Right End”

    Inner edge of the backshell at the latch. See line drawing for details.

    Note: Not Available with Printed Direct Attach (PDA) option

    A B

    C D

    E F

    G H

    I J

    K L

    Z-A

    xis

    Cab

    le E

    gres

    s

    Z-A

    xis

    Cab

    le E

    gres

    s

    Z-A

    xis

    Cab

    le E

    gres

    s

    Z-A

    xis

    Cab

    le E

    gres

    s

    S T

    Y Z

    W X

    M

    P

    Cable Assembly Nominal Length

    Note: The broken line view is from the rear of the backshell and the solid line view is from the mating face of the connector.

    Tolerance: 10 Meter, +/– 100mm

    S1 Short Side Dn 4X/12X Straight Cable Egress Straight Cable Egress 4X/12X Short Side Up S1

    Short Side Up S1 4X/12X Straight Cable Egress Straight Cable Egress 4X/12X S1 Short Side Dn

    S1 Short Side Dn 4X

    4X

    4X

    4X

    Short Side Up S1

    S1Short Side Up Short Side Dn S1

    Angled Cable Egress

    Angled Cable Egress

    Angled Cable Egress

    Angled Cable Egress

    4X

    4X

    Short Side Up S1

    Short Side Dn S1

    Angled Cable Egress

    Angled Cable Egress

    4X

    4X

    Angled Cable Egress S1 Short Side Dn

    Angled Cable Egress S1 Short Side Up

    Short Side UpShort Side Dn

    Short Side UpShort Side Dn

    4X 4X

    4X 4X

    N

    O

    Cable Egress Cable Egress

    No Termination No Termination

    Outer Jacket Strip Outer Jacket Strip

    Custom/Other Conn.Custom/Other Conn.

    4X | 12XMechanical

    Orientation

    6 High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ www.meritec.com

    888-MERITEC (637-4832)

  • HBWHyBrids

    + Options

    12X Daisy Chains

    Belly-to-Belly Configuration

    (2) 4X Angled 4X – (3) eSATA

    4X Z-Axis Configuration

    12X – (3) 4X Connections

    QSFP+

    SFP+

    888-MERITEC (637-4832) High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ 7

    www.meritec.com

  • Meritec’s Feed-Thru Connectors are RoHS Compliant

    P2P1

    1.550

    1.330

    .281 .417

    .600

    1.000

    (.030) (.035)

    .775

    2X 4-40 UNC .17

    .575

    4X 4-40 UNC .22

    Receptacles

    Board Receptacle & Feed-Through Mounts Available

    Thumbscrew-to-Thumbscrew P/N 984001-004-T

    RoHS Compliant

    Also Available:Latch-to-Latch P/N 984001-004-L

    Latch-to-Thumbscrew P/N 984001-004-LTS

    Thumbscrew-to-Latch P/N 984001-004-TSL

    4-Lane Feed-Thru Connector

    Feed-Thru PinoutP1 P2S1 S16S2 S15S3 S14S4 S13S5 S12S6 S11S7 S10S8 S9S9 S8S10 S7S11 S6S12 S5S13 S4S14 S3S15 S2S16 S1

    Panel-Mount Receptacle-Cable

    Termination

    New!New!

    Consult factory.

    8 High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ www.meritec.com

    888-MERITEC (637-4832)

  • NX+ Board-Mount Receptacle SFF-84734X & 12X Available

    12.7 RemovablePick-and-Place Tab

    13.0

    8.50.5

    Shown with optional panel mountShown without optional panel mount

    29.8

    34.3

    2X 2-56 UNC Thru

    Shown with optional side panel mount

    S1

    S1

    6.6

    S1

    6.4

    M2X0.4 Thru

    4.

    9

    12

    .7

    EMIGasket

    (Optional)

    24.9

    6.0

    11.3

    13

    .0

    14

    .9

    2.5 10

    .2

    15

    .4

    Visit www.meritec.com to download the complete SFF-8473 Datasheet. E-mail: [email protected]

    Board Mount

    Features & Benefits• Improved crosstalk and insertion loss• Performance enhanced to 20 Gb/s

    per differential pair or lane, in combination with Meritec enhanced NX-capable assemblies

    • Die-cast housing for rugged application• Screw & solder post hold-down features• Top and/or side-panel mount(s) available

    • Latch & thumbscrew options available• Removable tab for pick-&-place

    applications• SMT configuration• Supports Ethernet CX4, Myrinet, RapidIO,

    Aurora and other high-speed applications

    Specifications / Visit www.meritec.com/catalog

    888-MERITEC (637-4832) High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ 9

    www.meritec.com

  • SFP+ & QSFP+SFF-8436, SFF-8470

    SFF-8431, SFF8432

    PAD 11

    PAD 10

    PAD 20Latch Pull

    A

    Detail A

    Oprionl: Overmolded Plastic Nose Piece (Under Development)

    PAD 018.55±0.15

    13.55±0.25

    57.50 Ref.

    Length

    Wiring DiagramP1 End P2 End

    Pad Signal Pad Signal

    01 GND 20 GND02 TX2n 21 RX2n03 TX2p 22 RX2p04 GND 23 GND05 TX4n 24 RX4n06 TX4p 25 RX4p07 GND 26 GND13 GND 32 GND14 RX3p 33 TX3p15 RX3n 34 TX3n16 GND 35 GND17 RX1p 36 TX1p18 RX1n 37 TX1n19 GND 38 GND20 GND 01 GND21 RX2n 02 TX2n22 RX2p 03 TX2p23 GND 04 GND24 RX4n 05 TX4n25 RX4p 06 TX4p26 GND 07 GND32 GND 13 GND33 TX3p 14 RX3p34 TX3n 15 RX3n35 GND 16 GND36 TX1p 17 RX1p37 TX1n 18 RX1n38 GND 19 GND

    SFP+

    Chart Suffix Wire Gauge (AWG)Length in Meters

    at 10 Gb/sTolerance at

    Maximum LengthA= 24 7 ± 70.0 mmB= 26 5 ± 70.0 mmC= 28 3 ± 70.0 mmD= 30 1 ± 70.0 mm

    SFP+Passive Copper-Cable Assemblies are RoHS Compliant

    Note: Tolerance of ± 40.0 mm for lengths of 0.5M to 1.0M consult factory for lengths less than 0.5M.

    Part Number Ordering Specification:

    9846 - Chart Suffix

    (AWG)

    – Length In Meters

    10 High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ www.meritec.com

    888-MERITEC (637-4832)

  • P1 P2PAD 20

    PAD 19

    PAD 38

    PAD 01

    18.35±0.1

    8.5±0.1

    86.05

    Length

    QSFP+

    Features & Benefits• Enhanced EMI shielding for low emissions• Ultra low crosstalk for enhanced

    performance• Mates with all standard SFP+/QSFP interfaces• Lower cost alternative to fiber optics• RoHS Compliant & EEPROM Programmable

    Cable Specifications• Supports/Exceeds 40 Gb/s Ethernet

    IEEE802.3ba• SFF-8431/SFF-8436 Compliant• Fully shielded assembly with drain wire• Die cast metal housings• Ergonomic pull style latch to de-latch with

    positive locking mechanism

    Environmental Specs• Material – UL flame rating: 94V – 0• Temperature rating: –10 °C to +70 °C

    QSFP+Passive Copper-Cable Assemblies are RoHS Compliant

    Part Number Ordering Specification:

    9841 - Chart Suffix

    (AWG)

    N N – Length In Meters

    888-MERITEC (637-4832) High Bandwidth NX | Mini -SAS | OSFP+ | SFP+ 11

    www.meritec.com

  • HIGH BANDWIDTHHIGH BANDWIDTH

    HIGH BANDWIDTHHIGH BANDWIDTH

    Solving Interconnect Problems Quickly Since 1966

    Design Through Manufacture of High-Performance-Interconnect Systems,Connectors & Cable Assemblies

    Innovative-Interconnect Solutions

    NX | Mini-SAS | QSFP+ | SFP+

    Innovative-Interconnect Solutions

    Visit us online!

    1359 West Jackson Street • Painesville, Ohio 44077 USA 440-354-2100 • Fax: 440-354-5692 • 800-860-9014 • 888-MERITEC (637-4832) www.meritec.com • E-mail: [email protected]

    © Meritec 061920 • All rights reserved. • Document Number 0145883 Connectors Unlimited (CUI) and Mold-Tech (MT) Divisions are now merged and DBA Meritec.

    1020 Marauder Street Chico, California 95973 USA 530-891-3551, Fax: 530-891-3599 888-891-3551 (Toll Free) www.joysignal.com E-mail: [email protected]

    www.connectorsunlimited.com ISO Certification 9001:2015

    NAICS# 334417 • 334418 334419 • 335929 • 335999Cage CodesMeritec 0RAG4 Connectors Unlimited 49MH9 Joy Signal Technology 1SJC3 Mold-Tech 1BCG6

    http://www.meritec.com

    High Bandwidth from Meritec4X (SFF-8470) Direct Attach12X (SFF-8470) Direct AttachData Rate – Wire Gauge vs. Performance Over Length4X/12X Assembly Description4X/12X Mechanical OrientationHBW Hybrids +OptionsNX+ Receptacles4-Lane Feed-Thru ConnectorBoard Mount Features & BenefitsSFP+QSFP+Meritec Contact Information

    Button 2: Page 1:

    Button 3: Page 12: