Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

Non-Structural IsolationQUAKEBASE - PLATFORMS - 3D ISOLATION - FLOORS - MODULAR SYSTEMS

Page 2: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

1www.dis-inc.com

DIS is the World Leader in Seismic Isolation - no other company has completed more isolation projects in more countries than Dynamic Isolation Systems.

Dynamic Isolation Systems

1

Critical equipment in the Salt Lake City Public Safety Building in Utah, USA is protected by an extensive DIS Isolated Platform System.

Vertical isolation system for hydro-electric facility.

Introduction

QuakeBaseAn engineered, low-prof ile solution to protect servers.

Isolated PlatformsProtection for data centers, medical and industrial equipment, ar twork and computer servers.

3D IsolationSeismic protection for applications which require acceleration reduction both horizontally and ver tically.

Floor Isolation Seismic protection for essential equipment housed within conventionally designed structures.

Modular Isolation SystemsProtect modular data centers from seismic eventsand downtime.

Frequently Asked Questions

1

2

4

6

8

10

12

Ideal candidates for non-structuralisolation include:

Computer Servers

Modular Data Centers

Prefabricated Structures

Artwork, Including Statues

Industrial Equipment

Emergency Command Centers

Data Center Floors

Medical, High-Tech & Electrical Equipment

An Industry PioneerDynamic Isolation Systems is an industry pioneer and continues to develop and add technologies to its growing list of seismic protection solutions.

DIS designs and manufactures systems for structural and non-structural isolation applications, including: base isolation, viscous wall dampers, pot bearings, sliders, isolated f loor systems, modular isolation, isolated platforms, ver tical isolation and isolation both horizontally and vertically.

Non-Structural IsolationWhen isolating an entire structure is not an option, DIS has a number of solutions to protect vital equipment and ar twork from the damage or downtime caused by a seismic event.

Table of Contents

www.dis-inc.com

Page 3: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

2www.dis-inc.com

An engineered, low-profile solution for protecting new and existing cabinets and equipment.

DIS QuakeBase

What is QuakeBase?QuakeBase is an isolated platform that uses double concave sliders to protect from earthquake damage. It’s designed to be an economical solution for low to medium seismic zones.

How does QuakeBase Function?QuakeBase works on the same principals as a simple pendulum. Energy from an earthquake is dissipated through friction at the sliding interface. Movement of the system is controlled by the curvature of the sliding surfaces.

QuakeBase is modular and can be configured to suit any server or equipment layout. Adjacent modules bolt together to form a continuous system.

Ideal Candidates for QuakeBase

Mainframes

Server Racks

Optical Storage Units

Servers remain stationary duringevery day use and maintenance.

Easy installation in both newand existing data rooms.

Advantages of QuakeBaseQuakeBase reduces earthquake energy transmitted into servers by decoupling them from the ground during a seismic event. In addition, QuakeBase removes energy through internal friction.

QuakeBase’s low height allows for easy installation in both new and existing data rooms. No drilling is required for installation.

Due to the friction interface in QuakeBase, servers remain stationary during everyday use and maintenance.

Concave sliding surfaces control seismic response.

QuakeBase is sized to accommodate standard server cabinets.

Page 4: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

3www.dis-inc.com

DIS QuakeBase

www.dis-inc.com

Performance Typical equipment is capable of remaining operational at accelerations up to 0.3g. The use of isolation limits the accelerations transmitted from the f loor into the equipment allowing it to remain functional in larger seismic events.

Energy dissipation enables QuakeBaseto accommodate larger earthquakes.

QuakeBase limits accelerations imparted into equipment to safe operating levels.

QuakeBase safely accommodates larger earthquake inputs.

The Allowable Earthquake Input for Equipment Operation f igure (right) demonstrates the dif ferent levels of earthquake that can be safely accommodated without the use of isolation (Non-Isolated), utilizing an isolation system with lit tle to no energy dissipation (Un-Damped) and an isolation system with energy dissipating characteristics (QuakeBase).

Page 5: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

4www.dis-inc.com

Protection for data centers, medical and industrial equipment, artwork and computer servers.

DIS Isolated Platform (IP)

Ideal Candidates for Isolated Platforms

Computer Servers

Medical Equipment

Manufacturing Equipment

Artwork, Including Statues

Why Use An Isolated Platform?Computer servers and systems are key to business operation in todays data-dependent world.

Isolated Platforms provide protection against server downtime and equipment damage in the event of an earthquake.

More Server Uptime Protecting data centers and essential equipment against system failure with backup power and mirrored storage are common practice.

However, protection against seismic forces is also vital. Conventional earthquake protection utilizes strengthening techniques which actually increase seismic forces and accelerations. Conversely, Isolated Platforms reduce equipment forces.

Systems and equipment remain undamaged, operational and on-line. Seismic isolation has been utilized to achieve Uptime Institue’s Tier 4 rating in seismic zones.

ConfigurationsDIS’ patented IP is comprised of Multi-Directional Springs and high-load capacity rolling supports housed within an attractive steel frame. Modules are available in Standard (4ft x 4ft) and Extended (4ft x 6ft) sizes.

Individual platforms can be bolted together on all four sides, allowing for versatile layouts. (i.e., for supporting single servers or a long row of server racks.)

Platform heights range from 7 to 11 inches, depending on the required load capacity.

PerformanceDuring a seismic event the Isolated Platform decouples the system from f loor motions and absorbs seismic energy. The f loor moves beneath the IP, leaving what it supports largely unaffected. Transmitted accelerations are reduced by up to 5 times.

Standard DIS Isolated Platforms are designed for 100psf to 500psf f loor loading in moderate to high seismic regions. Custom engineered solutions are available to suit any application.

Drastically reduces earthquake hazard.

Individual platforms can connect together, allowing for versatile layouts.

Solutions available to suitany application.

Overhead cable trays are easily used with DIS’ Isolated Platform.

40’ long Isolated Platform houses two banks of servers and IT equipment.

Page 6: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

5www.dis-inc.com

DIS Isolated Platform (IP)

www.dis-inc.com

These 20 foot tall bronze statues in a California park are isolated on DIS platforms capable of moving +/-30” in an earthquake.

Individual Isolated Platforms bolt together to accommodate various configurations.

Patent No. US 8,061,692 B1

Dimensions: Plan size 2ft larger than IP to allow for movementFlatness Finish: FF 50Levelness Finish: FL 30 Designed to Support: 3,000 lb. point loads

Finished Floor Requirements

Page 7: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

6www.dis-inc.com

Seismic protection for applications that require acceleration reduction horizontally and vertically.

DIS 3D Isolation

The Need for 3D Isolation?Seismic isolation is typically engineered to protect against horizontal accelerations during a seismic event. In some applications, however, signif icant ver tical accelerations are present as well. DIS has developed a solution to reduce these forces.

Dynamic Isolation Systems developed a product which provides isolation from damaging accelerations in both horizontal (X, Y) and vertical (Z) directions.

The solution for isolating in both the horizontal and vertical directions came about when a major hydro-electric dam project needed to protect critical equipment from extreme vertical accelerations.

The equipment at the top of the hydro-electric dam was subjected to spectral accelerations up to 17g. These large accelerations would damage sensitive equipment following a seismic event causing dam controls to be inoperable.

DIS developed 3D isolation platforms to reduce forces and accelerations transmitted into the equipment to be within IEEE 693 High Per formance code requirements. The successful development of 3D isolation led to the client incorporating vertical isolation systems in several additional applications.

DIS’ 3D isolation systems are the most ef fective and complete solution for addressing earthquake hazards. DIS specializes in custom design, development, and manufacturing of solutions such as 3D isolation.

Components of the 3D isolation system.

Vertical isolation system designed to protect hydro-electric dam equipment.

3D shake table testing of DIS’ 3D isolation system at Dynamic Certification Laboratories.

Meet or exceed code requirements.

Most effective and complete solutionfor addressing earthquake hazards.

Page 8: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

7www.dis-inc.com

DIS 3D Isolation

www.dis-inc.com

ConfigurationDIS’ 3D isolation system uses a series of guided bearings, ver tical and horizontal springs and dampers to achieve superior per formance during a seismic event.

3D isolation system dimensions and capacities are determined on a project by project basis by DIS’ team of seismic design experts.

PerformanceSeveral shake table test programs wereconducted at the University of Nevada, Reno (UNR) and Dynamic Certif ication Laboratories(DCL).

The system per formed as designed. The spectral accelerations were reduced by a factor of 18, protecting essential equipment against the most extreme seismic inputs.

The critical components of the vertical Isolation system are visible in this image.

Shake table testing of DIS’ vertical isolation system at the University of Nevada, Reno.

Shake table testing shows 3D Isolation reduced spectral accelerations satisfying IEEE 693 High Performance requirements.

Spectral accelerations reducedby factors of 10 to 20.

Patent No. US 8,061,692 B1

Page 9: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

8www.dis-inc.com

DIS Isolated Floor (IF)

Seismic protection for essential equipment housed within conventionally designed structures.

Ideal Candidates for Isolated Floors Emergency Operation Centers

Data Centers

Large Floor Areas

Raised Floor Configurations

Why Use An Isolated Floor?Risk management for computer servers and data centers is an integral par t of modern business.

Often the productivity of an entire company hinges on the reliable and continuous operation of its computer equipment.

In addition to backup power and mirrored data storage, seismic isolation is a critical piece of the risk management puzzle.

DIS Isolated Floor systems provide continuous, single-level f looring with seamless integration of conventional, raised-access f loors.

Conventional earthquake protection relies on structural strengthening techniques, which actually increase seismic forces and accelerations. DIS’ Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event.

Seismic isolation has been utilized to achieve Uptime Institute’s Tier 4 rating in seismic zones.

ConfigurationDIS’ patented Isolated Floor is comprised of Multi-Directional Springs and high-load capacity rolling supports in standard 4ft x 6ft modules which accommodate standard 2ft x 2ft access f loor tiles.

Modules are connected with either 2ft, 4f t or 6ft stringers and may be connected on all four sides, allowing for custom configurations.

Under f loor utilities may be organized through incorporated cable trays and remain accessible via standard access f loor tiles or placed on the f loor below the stringers.

Cable trays incorporated for easy accessand organization of utilities.

Systems and equipment remain undamaged, operational and on-line.

More server up time.

Floor heights available from 1 to 4 feet.

Full scale isolated floor with seismic moat.

Installation of a 16,000 square foot isolated floor at the UC Berkeley, Computational Research and Theory Facility.

Page 10: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

9www.dis-inc.com

DIS Isolated Floor (IF)

www.dis-inc.com

Please contact DIS for floor layout details.

3D shake table testing of DIS’ floor isolation system at the University of California, Berkeley.

Performance During a seismic event the Isolated Floor decouples the system from the f loor slab. The f loor slab moves beneath the Isolated f loor system, eliminating damage to equipment.

Standard DIS Isolated Floors are designed for 100psf to 500psf f loor loading in moderate to high seismic regions. Engineered solutions are available to suit any application.

Patent No. US 8,061,692 B1.

Dimensions: Plan size 2ft larger than IF to allow for movementFlatness Finish: FF 50Levelness Finish: FL 30 Designed to Support: 3,000 lb. point loads for 100psf areas to 15,000 lb. point loads for 500psf areas

Finished Floor Requirements

Page 11: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

10www.dis-inc.com

DIS Modular Isolation System (MIS)

Why Use A Modular Isolation System?Modular data centers are a key component for business operations in today’s growing data industry. DIS’ Modular Isolation System (MIS) provides protection against server downtime and equipment damage in the event of an earthquake.

Installing backup power and having mirrored storage are common practices for protecting data centers and essential equipment.

However, the missing piece of this risk management puzzle has been the protection from seismic events. This can be provided by DIS’ Modular Isolation System.

Conventional earthquake protection utilizes strengthening techniques, which actually result in increased seismic forces. The MIS, however, reduces seismic forces. Systems and equipment remain undamaged, operational and on-line.

PerformanceDIS’ patented MIS is comprised of Multi-Directional Springs (MDS) and high load capacity rolling supports housed within an attractive steel frame. The frame matches the footprint of a standard modular data center and is only 12” (300mm) tall.

During a seismic event the ground moves beneath the MIS, leaving the data center and its equipment unaffected by the earthquake. The MIS decouples the data center from the ground and absorbs seismic energy.

Standard MIS’ are designed for 25,000 to 65,000 pound modular data centers in moderate to high seismic regions. Custom solutions are available for any application.

Modular Data Center In Costa Rica. It performed well in a 2012 magnitude 7.6 earthquake.

A modular isolation system ready to accept modular data center.

Transmitted accelerations are reduced by up to 5 times.

Exceptional performance was seenin a magnitude 7.6 earthquake.

Protection against server downtimeand equipment damage.

Seismic isolation has been utilizedto achieve Uptime Institute’s Tier 4

rating in seismic zones.

Protect modular data centers from seismic events and downtime.

Page 12: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

11www.dis-inc.com

DIS Modular Isolation System (MIS)

www.dis-inc.com

MIS-20S Configuration

MIS-40S and MIS-53S Configuration

MIS-40H and MIS-53H Configuration

Dynamic control modules support vertical load, control seismic movement, and house DIS’ patented Multi-Directional Spring units.

Dynamic control modules support vertical load and allow seismic movement.

Dimensions: Container size plus 2ft perimeter Flatness Finish: FF 50Levelness Finish: FL 30 Designed to support: 10,000 lb. point loads

Concrete Pad requirements

Patent No. US 8,061,692 B1Contact DIS for custom sizes and designs.

Page 13: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

12www.dis-inc.com

Frequently Asked Questions

12

What benefit can be expected from seismic isolation?

Typical force and acceleration reductions are on the order of 3 to 5 times and can be as much as 20 times.

What are the maintenance requirements for DIS isolation systems?

DIS isolation systems are maintenance free devices. The area surrounding the devices should be checked periodically to ensure the system can freely translate during a seismic event.

Are specialty contractors required for installation of DIS devices?

DIS isolation devices are installed by general contractors, facilities or maintenance crews. Most connections are simply bolted together and anchored to the f loor. Detailed installation manuals are provided with all systems and DIS of fers on-site installation support.

What testing has been performed to qualify the performance of the systems?

DIS’ various isolation systems have been extensively shake table tested at university laboratories and independent cer tif ication laboratories under full load and earthquake conditions over the past decade.

Do the systems require replacement after a seismic event?

DIS isolation systems are capable of protecting against multiple large scale events and do not require replacement after an earthquake.

Has DIS ever had a failure in the field?

DIS has completed over 450 isolation projects on some of the most high profile projects in the world, dozens of which have been subjected to seismic events. All projects have per formed as expected and none have required replacement after an earthquake.

Are there any limits to the use of DIS isolation systems?

DIS team of international experts in the f ield of seismic isolation verify that every project receives the solution that best f its its specif ic needs.

Do DIS isolation systems incorporate any means of organizing cables and utilities?

Overhead cable trays for utilities can be incorporated into Isolated Platform systems and under f loor cable trays for utilities can be incorporated into Isolated Floor systems.

Are custom designs available for unique applications?

DIS specializes in custom design applications and can of fer a full range of design, detailing, and manufacturing services, including stamping by a licensed engineer if required.

www.dis-inc.com

Page 14: Non-Structural Isolation · Isolated Floors reduce seismic forces. Systems and equipment remain undamaged, operational and on-line both during and after a seismic event. Seismic isolation

www.dis-inc.com

The World Leader in Seismic Protection

885 Denmark Drive, Suite 101McCarran, Nevada 89434 USA

T: 775.359.3333 F: 775.359.3985www.dis- inc.com

Copyright © 2016 Dynamic Isolat ion Systems, Inc.Al l r ights reserved.