4
STRATE Technologie für Abwasser GmbH Im Kirchenfelde 9 · D-31157 Sarstedt Telefon (050 66) 9 88-0 · Fax -225 www.strate.com Non-return valves STOP STRATE AWASTOP non-return valve Are recognised all over the world as non-return valves for universal applications in the pumping of fresh water, effluent, sludge and air Stand for high operational safety Stand out thanks to their excellent value-for-money and low mainte- nance requirements Offer as a mature design: 100 % free passage Low flow resistance Quiet operation thanks to the inclined valve seat which shortens the closing distance Minimum clogging tendency through optimum hydraulic design Fail-safe closing of the valve since the closing element is fixed secu- rely into the valve cover Easy installation due to the screw- less valve attachment for simple replacement of the closing element Leakproof even with low counterpressure Flow resistance (water, effluent) Areas of application Due to their special design, 100 % free passage and low flow resistance, STRATE AWASTOP non-return valves are ideal for: Sewage technology, media with solids and coarse solids, sludge (up to 5 % TM) Fresh and service water technology, including in areas where high pres- sure losses make powerful pumps necessary On request: pumping of fluids devia- ting from the media listed Areas where quiet operation is par- ticularly important Special cases In pipe networks where pressure surges are to be expected due to topographical routing and hydraulic circumstances, further products from the STRATE special fittings range may be required, such as STRATE non-return valves with spring loading, STRATE venting and air release valves etc. STRATE project engineers will be happy to answer any questions you or your planning office may have related to the selection of the suitable STRATE non-return valve system or other matters. STRATE AWASTOP non-return valve

Non-return valves STOP · STRATE Technologie fr Abwasser GmbH Im irchenfelde 9 D-31157 Sarstedt Telefon (050 66) 9 88-0 Fax -225 Non-return valves STOP STRATE AWASTOP. non-return

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Non-return valves STOP · STRATE Technologie fr Abwasser GmbH Im irchenfelde 9 D-31157 Sarstedt Telefon (050 66) 9 88-0 Fax -225 Non-return valves STOP STRATE AWASTOP. non-return

STRATE Technologie für Abwasser GmbH Im Kirchenfelde 9 · D-31157 Sarstedt Telefon (050 66) 9 88-0 · Fax -225 www.strate.com

Non-return valvesSTOP

STRATE AWASTOP non-return valve

• Are recognised all over the worldas non-return valves for universalapplications in the pumping of freshwater, effluent, sludge and air

• Stand for high operational safety

• Stand out thanks to their excellentvalue-for-money and low mainte-nance requirements

• Offer as a mature design:

− 100 % free passage − Low flow resistance − Quiet operation thanks to theinclined valve seat which shortens the closing distance

− Minimum clogging tendency through optimum hydraulic design

− Fail-safe closing of the valve since the closing element is fixed secu-rely into the valve cover

− Easy installation due to the screw-less valve attachment for simple replacement of the closing element

− Leakproof even with low counterpressure

− Flow resistance (water, effluent)

Areas of application

Due to their special design, 100 %free passage and low flow resistance,STRATE AWASTOP non-return valvesare ideal for:

• Sewage technology, media withsolids and coarse solids, sludge (upto 5 % TM)

• Fresh and service water technology,including in areas where high pres-sure losses make powerful pumpsnecessary

• On request: pumping of fluids devia-ting from the media listed

• Areas where quiet operation is par-ticularly important

Special cases

In pipe networks where pressuresurges are to be expected due totopographical routing and hydrauliccircumstances, further products fromthe STRATE special fittings rangemay be required, such as STRATEnon-return valves with spring loading,STRATE venting and air releasevalves etc.

STRATE project engineers will behappy to answer any questions youor your planning office may haverelated to the selection of the suitableSTRATE non-return valve system orother matters.

STRATE AWASTOP non-return valve

Page 2: Non-return valves STOP · STRATE Technologie fr Abwasser GmbH Im irchenfelde 9 D-31157 Sarstedt Telefon (050 66) 9 88-0 Fax -225 Non-return valves STOP STRATE AWASTOP. non-return

STRATE Technologie für Abwasser GmbH Im Kirchenfelde 9 · D-31157 Sarstedt Telefon (050 66) 9 88-0 · Fax -225 E-Mail: [email protected]

Non-return valvesSTOP

Description

The unsurpassed reliability and servicelife of the STRATE AWASTOP non-returnvalves are the result of years of productobservation and the development ofa holistic design without a large numberof components. Screws are only neededto fix the inspection cover in place.

The closing element with its vulcanisedclosing plate is the moving part in theSTRATE AWASTOP. The closing elementis mounted between the inspectioncover and the housing and is easilyaccessible for replacement. The evengeometry in the pivoting range preventspendulum movements and guaranteesthe perfect guiding of the closingelement. The inclined valve seat isa special advantage, since it significantlyshortens the closing time and reducesclosing noise. The pronounced sealinglip profile makes the non-return valveclose tightly and reliably even whencounterpressure is low. The butyl rubberB 100 used, which has a Shore hardnessof 55-60 Shore, is suitable for operatingtemperatures from −35°C to +120°C.Depending on the individual applicationcase, other elastic materials such as

Face-to-face dimension in

accordance with DIN EN

558-1

*Lifting device

Flange connection dimen-

sions and bore holes in

accordance with DIN EN

1092-1/2 (PN10)

Operating temperatures

from –35°C to +120°C

Shore hardness of the

Materials

Housing, cover: EN-GJL-250 (GG 25)

Closing element: Butyl B100 with vulcanisedclosing plate

Cover seal: Butyl B100

Coating: Electrostatic plastic coating

Lifting device: Stahl – C 45

Technical data

DN PN Face-to-facedimension mm

Weight with and without LD* kg

50 10 200 10

65 10 240 15

80 10 260 18

100 10 300 24

125 10 350 34

150 10 400 46

200 10 500 86

250 10 600 142

300 10 700 206

Flow speed and installation position

• Pumping of liquid media with flowspeeds up to 1.5 + 0.5 m/s

• Vertical installation position –upward direction of flow

• Horizontal installation position –inspection cover at the top; recom-mended installation position wherethere is a high solids share (e.g.sand, gravel, stones)

Page 3: Non-return valves STOP · STRATE Technologie fr Abwasser GmbH Im irchenfelde 9 D-31157 Sarstedt Telefon (050 66) 9 88-0 Fax -225 Non-return valves STOP STRATE AWASTOP. non-return

STRATE Technologie für Abwasser GmbH Im Kirchenfelde 9 · D-31157 Sarstedt Telefon (050 66) 9 88-0 · Fax -225 www.strate.com

Non-return valvesSTOP

Perbunan, Viton, silicone etc. can be used to make operating temperaturesfrom −35°C to +230°C possible.

All non-return valves in the STRATEAWASTOP range provide 100 % freepassage thanks to the perfect design ofhousing and closing element. In prac-tice, this results in low flow resistance,minimum clogging tendency, ease ofmaintenance and quiet operation.

The sealing lip ensures

optimum sealing

• Can be selected after consultationwith us, please return the projectplanning sheet to us by e-mail, faxor post for this purpose.

The perfect non-return valve for your special needs

You will find your project planning sheet in this catalogueunder “Project planning aids”.

You can also find an online version in our download centre!www.strate.com

STRATE project engineers will behappy to answer any questions you oryour planning office may have relatedto the selection of the suitable STRATEnon-return valves or other matters.

F

100 % free passage with the

valve opened

Page 4: Non-return valves STOP · STRATE Technologie fr Abwasser GmbH Im irchenfelde 9 D-31157 Sarstedt Telefon (050 66) 9 88-0 Fax -225 Non-return valves STOP STRATE AWASTOP. non-return

STRATE Technologie für Abwasser GmbH Im Kirchenfelde 9 · D-31157 Sarstedt Telefon (050 66) 9 88-0 · Fax -225 E-Mail: [email protected]

Non-return valvesSTOP

Copyright according to DIN 34Sample drawing: AWASTOP

Scale:

Subject to technical modifications and errors.

STRATE Technologie für Abwasser GmbHIm Kirchenfelde 9 · D-31157 SarstedtPhone +49 (0)5066 988-0 · Fax -225E-mail: [email protected]

Non-return valvesSTOP

Dimensions in mm Weight

10.0

15.0

24.0

34.0

46.0

86.0

142.0

206.0

Lifting device up to DN 125

Lifting device from DN 150

18.0

Copyright according to DIN 34Sample drawing: AWASTOP

Scale:

Subject to technical modifications and errors.