Noise exposure forecast at workplaces BUY QUIET 2016 Wolfgang Probst DataKustik GmbH · Dornierstr. 4 · 82205 Gilching · Germany Tel: +49 8105 77467 111 [email protected] www.datakustik.com

Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Noise exposure forecast at workplaces

BUY QUIET 2016

Wolfgang Probst

DataKustik GmbH · Dornierstr. 4 ·

82205 Gilching · Germany

Tel: +49 8105 77467 – 111

[email protected]

www.datakustik.com

Page 2: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

SERT (Sound Energy Ray Tracing)

Page 3: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Measurements in 122 industrial halls have been performed during development of

guideline VDI 3760 with financial support of BAuA

German guideline to calculate sound propagation:

Page 4: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Measurements along straight paths with dodecahedron as calibrated source

Page 5: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Data to describe room, source, path and measured

sound pressure levels

Model of the room with machinery and path

Page 6: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Comparison of measured levels with those calculated with SERT-method : Room AF00116 empty

Page 7: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Comparison of measured levels with those calculated with SERT-method : Room AF00116 with absorbing ceiling

Page 8: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Comparison of measured levels with those calculated with SERT-method : Room AF00116 with absorbing ceiling

and machinery installed

Page 9: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

50%

Statistical analysis of the deviations for 122 halls: mean value < ± 1 dB, 50% < ± 2 dB

Page 10: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Emission of sources

Machine directive 2006/42/EC

Immission at workplaces Technical Layout and

architectural design

Noise prediction

Physical Agents

Noise Directive 2003/10/EC

Lower exp. action value Lex,8h = 80 dB(A)

Upper exp. action value Lex,8h = 85 dB(A) :

:

Emission sound pressure level LpA if > 70 dB(A)

+

Sound power level LWA if LpA > 80 dB(A)

Noise prediction with software techniques links the requirements of Noise directive with declared emission values

Page 11: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Speaking person Simulation as point source

Page 12: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces
Page 13: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces
Page 14: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces
Page 15: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces
Page 16: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces
Page 17: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

source receiver

Energy related impulse response

Time

Page 18: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Detailed modeling of a washing machine

Page 19: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Washing machine in a room Free field calculated noise map

(only ground reflection included) Noise map with all relevant reflections

Page 20: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Modeling of a complex machine as a box (equal to reference surface acc. to ISO 3744)

Page 21: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Gravure printing machine Simulation with 4 radiating stations

Page 22: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Radiating areas

Operators position

Emission values LWA and LpA Declaration according to machine directive

Radiating areas and source distribution Inspection

Page 23: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Determination of effectiv radiated sound power level by simulating the enveloping surface method with

receivers on half sphere surface

Page 24: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

SERT-calculation of the level with semi-free-field conditions at the operators position LpA,sim

Emission sound pressure level known (e.g. declared by manufacturer) LpA

Page 25: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Calculation LpA,sim for M1

Calculation LpA,sim for M2

Data-organisation in object-tree

Page 26: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Calculation LAp,sim for M1 and M2 (reflections at room surfaces neglected to keep

presentation simple)

For each receiver at a workplace with declared LpA:

Page 27: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Sound power level LWA Emission sound pressure level LpA

Emission values of Palletizer and Depalletizer - 1981

Page 28: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

98

100

102

104

106

108

0 1 2 3 4 5 6

Sc

ha

llle

istu

ng

sp

eg

el

dB

(A)

Durchsatz in 1000 Ka/h

Ent-Bepalettiermaschinen: Schallleistungspegel LWA

LWA,2

LWA,1

LWA

76

78

80

82

84

86

0 1 2 3 4 5 6Em

iss

ion

s-S

ch

allp

eg

el

dB

(A)

Durchsatz in 1000 Ka/h

Ent-Bepalettiermaschinen: Emissionsschallpegel LpA

LpA,2

LpA,1

LpA

Sound power level LWA Emission sound pressure level LpA

Advices for modelling and source distribution (default)

Proposal for a revision of VDI 4741 - 2016

Page 29: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Acoustic model of the palletizer machine

Page 30: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Visualization of sound particles radiated by the palletizer (LWA 104 dB, LpA 82 dB)

Page 31: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Result from SERT-calculation in room with 6 m height Level at operators position is 87.3 dB(A)

Page 32: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Simulation of a complete plant with machinery and transport-systems

Page 33: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Absorbing baffle system at the ceiling

Page 34: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Absorbing baffle system at the ceiling integrated in the model

Page 35: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Production-line X13

Machine LWA LpA

Cooler CX14 96 -

Cleaning O+H 104 86

Inspection KR10C 101 84

Filler HuK236 104 83

Labeller KS 45C 99 82

Conveyor 128 108 -

Conveyor 129 101 -

: : :

: : :

What is needed:

The result determined by SERT - simulation:

Production-line X13

Machine LAp +MPack1 +MPack2

Cleaning O+H 89 87 84

Inspection KR10C 88 86 85

Filler HuK236 86 85 84

Labeller KS 45C 86 85 83

: : : :

: : : :

Emission values guaranteed by

the manufacturer

If the predicted LAp values are

exceeded, measurement of LpA in

accordance with ISO 11204

Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Page 36: Noise exposure forecast at workplaces - bruit · accordance with ISO 11204 Prediction in the planning phase – from declared emission values to the expected levels at the workplaces

Thank you for your attention