2
The Nodegrid Bold SR provides extensive access to the devices attached to this equipment. As a result, care must be taken to avoid compromising your security policies. From the factory, this equipment is shipped with the following settings: DHCP, SSHv2, HTTPS – ENABLED All Serial ports – DISABLED Ethernet, USB and Serial Console Ports – ENABLED Two default users with passwords: root root admin admin Note: root access to shell enabled on the console port only. ZPE recommends changing the default passwords of admin and root, as well as carefully configuring security settings immediately after initial setup. Please consult the Nodegrid Bold SR User Guide for more information on security settings. Quick Start Guide for Nodegrid Bold SR Security Warning For manual downloads and support, visit: www.zpesystems.com/resources/support For further assistance please contact ZPE Technical Support. 1 Desktop or Rack mount your Bold For detailed instructions, see the Nodegrid Bold SR User Guide. 2 Connect to your network Connect a ZPE-recommended CAT 5e or CAT 6 cable from the 1 GeB port to your network. Connect network devices to the network ports on the Bold. 3 Connect serial devices Using CAT 5e or CAT 6 cables, connect the appropriate serial devices to the serial ports on the Bold SR. 4 Connect USB devices Connect supported USB devices to the appropriate ports located on the back of the Bold SR. Nodegrid Bold SR shown DC power Ethernet Connected Devices Networking Routers Switches Gateways Compute Servers Blades (Linux, Windows Servers) Network Devices Power, SDN VMs, Virtual Machines IPMI/DRAC/iLO/CIMC, SSH/TELNET Servers Power Rack PDUs UPS Security Firewalls Security Devices Telecom Wireless Transmission Switching Designed for Network Admins, Sys Admins, IT Admins, Security Managers, Data Center, Colo Managers, DevOps, Engineers 4G/LTE Console USB 2.0/3.0 Serial Optional Serial VGA 1 Front Back 2 3 4 5 6 Optional Antenna By installing, copying, or otherwise using this device, you agree to be bound by the terms of the licensing, maintenance and sale agreements set forth on www.zpesystems.com/docs/legal. if you do not agree to the terms of those agreements, do not install or use the Hardware and/or Software Product(s). Wi-Fi Optional Antenna Option for rack mounting or desktop 6 TM Nodegrid Bold SR

Nodegrid Bold SR TM - ZPE SystemsThe Nodegrid Bold SR provides extensive access to the devices attached to this equipment. As a result, care must be taken to avoid compromising your

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Nodegrid Bold SR TM - ZPE SystemsThe Nodegrid Bold SR provides extensive access to the devices attached to this equipment. As a result, care must be taken to avoid compromising your

TheNodegridBoldSRprovidesextensiveaccesstothedevicesattachedtothisequipment.Asaresult,caremustbetakentoavoidcompromisingyoursecuritypolicies.

Fromthefactory,thisequipmentisshippedwiththefollowingsettings:

• DHCP,SSHv2,HTTPS–ENABLED

• AllSerialports–DISABLED

• Ethernet,USBandSerialConsolePorts–ENABLED

• Twodefaultuserswithpasswords:– root – root– admin – adminNote:rootaccesstoshellenabledontheconsoleportonly.

ZPErecommendschangingthedefaultpasswordsofadminandroot,aswellascarefullyconfiguringsecuritysettingsimmediatelyafterinitialsetup.

PleaseconsulttheNodegridBoldSRUserGuideformoreinformationonsecuritysettings.

QuickStartGuideforNodegridBoldSR

SecurityWarning

Formanualdownloadsandsupport,visit:www.zpesystems.com/resources/support

ForfurtherassistancepleasecontactZPETechnicalSupport.

1 DesktoporRackmountyourBoldFordetailedinstructions,seetheNodegridBoldSRUserGuide.

2 ConnecttoyournetworkConnectaZPE-recommendedCAT5eorCAT6cablefromthe1GeB porttoyournetwork.ConnectnetworkdevicestothenetworkportsontheBold.

3 ConnectserialdevicesUsingCAT5eorCAT6cables,connecttheappropriateserialdevicestotheserialportsontheBoldSR.

4 ConnectUSBdevicesConnectsupportedUSBdevicestotheappropriateportslocatedonthebackoftheBoldSR.

NodegridBoldSRshown

DC power

Ethernet

Connected Devices

NetworkingRoutersSwitchesGateways

ComputeServersBlades(Linux,

WindowsServers)

Network DevicesPower, SDN VMs, Virtual MachinesIPMI/DRAC/iLO/CIMC, SSH/TELNET Servers

PowerRack PDUs

UPS

SecurityFirewallsSecurity Devices

TelecomWireless

Transmission Switching

Designed forNetwork Admins, Sys Admins, IT Admins, Security Managers, Data Center, Colo Managers,

DevOps, Engineers

4G/LTE

Console

USB 2.0/3.0 Serial

Optional Serial

VGA

1Front Back

2

345

6Optional Antenna

Byinstalling,copying,orotherwiseusingthisdevice,youagreetobeboundbythetermsofthelicensing,maintenanceandsaleagreementssetforthonwww.zpesystems.com/docs/legal.ifyoudonotagreetothetermsofthoseagreements,donotinstallorusetheHardwareand/orSoftwareProduct(s).

Wi-Fi

Optional Antenna

Option for rack mounting or

desktop

6

TM

NodegridBoldSR

Page 2: Nodegrid Bold SR TM - ZPE SystemsThe Nodegrid Bold SR provides extensive access to the devices attached to this equipment. As a result, care must be taken to avoid compromising your

5 ConnectpowercableandturnontheBoldSR

Connectthepoweradaptertotheappliance.PressthepowerswitchtopoweronBoldSR.

6 ConnecttotheSerialConsoleport

UsingtheZPE’sRJ-45consoleadaptor,connectaterminalorworkstationtotheserialconsoleportontheBoldSR.TheBoldSRwillbeconfiguredusingaterminalorterminalemulatorwithsessionsettingsof:115,200,8,Nand1,withnoflowcontrol.

Alternatively,usetheVGAport.

Note:AllremainingmanualsetupstepsarerequiredthefirsttimeyouconfigureyourBoldSR.

7 Configurenetworkparameters

NOTE:Skiptostep8 ifyouhaveaDHCPenvironment.DHCPisthedefaultIPconfiguration.IfnoDHCPserverisavailable,pleaselogintoNodegridBoldSRviaitsconsoleportusingadmin credentialsandconfigureastaticIPaddressusingCLIinstructionsasfollows:[admin@nodegrid/]#cdsettings/network_interfaces/eth0/[admin@nodegrideth0]#setipv4_mode=static[admin@nodegrideth0]#setipv4_address=10.0.0.10ipv4_mask=255.255.255.0ipv4_gateway=10.0.0.1[admin@nodegrideth0]#showinterface:eth0macaddress:08:00:27:c4:cf:e5status=enabledipv4_mode=staticipv4_address=10.0.0.10ipv4_mask=255.255.255.0ipv4_gateway=10.0.0.1ipv6_mode=no_ipv6_address[admin@nodegrideth0]#commit[admin@nodegrideth0]#exit

ConnecttotheBoldconsoleport.Loginasroottochangetherootpassword.

8 Configureserial,network&USBdevices

Note:YourBoldwillrespondoverthenetworkat192.168.160.10 ifyourDHCPserverfailsorisunavailable.

Note: TocheckyourcurrentIPaddress,connecttotheBoldSRconsoleportandhitEnter attheloginpromptuntilyouseetheIPaddress.

ToconfiguretheBoldforthefirsttimeviaNetwork:

a)Openawebbrowser(HTTP/S)andenteritsIPaddressintheaddressfield.OrstartanSSHsessiontoyourBold’sIPaddress.

b)LogintoyourBoldasadmin.

c)SetyourNodegridBoldSRbasicconfiguration:

Step1– Security

Securityservicestab:Selectthedesiredservices,cryptographicprotocolsandciphersuitelevels.ClickSavewhenfinished.

Step2- Network

Networksettingstab:SetyourdesiredNetworkandInterfacesparameters.ClickSaveforeachsubmenu.

Step3- Ports

ManagedDevicestab:Selectlocalserialconsoleportcheckboxesandclick“Edit.”SetyourpreferencesandclickSavewhenfinished.

Step4- ChangeAdminPassword

Atanytime,[email protected]“ChangePassword”tochangeyoursystempassword.

Note: ConnecttotheBoldSRconsoleport.Loginasroot tochangeitspassword.

Congratulations!

YourNodegridBoldSRisnowconfiguredandreadytoacceptusersandconnectionstoitsports.

9 AdditionalConfiguration

NOTE:Werecommendthatyousetupanew Administratoraccount(inadmingroupwithfullprivileges)andusethenewaccountinsteadofthedefaultadmin account.

AddNewUsersClickSecuritytab,LocalAccounts,Add,setoptions,Save.

Alerts&loggingSetandsendalertsbyemail,SMS,and/orSNMP.

PowerControlnetworkattachedPDUpowerstripsandserver,networkandstoragedevices.

Foradvancedconfigurationoptions,how-tosandtipspleaserefertoyourBoldSRUserGuide.

10 Get technical updatesToautomaticallyreceivefuturefirmwareupdatesandtechnicalinformation,signuphere:www.zpesystems.com/loop/

QuickStartGuideforNodegridBoldSR

[email protected]

TM

NodegridBoldSR