N3000 SeriesRefrigerator
©Thetford 2018
Installation Manual Australian market
EUROPEAN HEADQUARTERThetford B.V.Nijverheidsweg 29P.O. Box 1694870 AD Etten-LeurThe Netherlands
T +31 (0)76 5042200F +31 (0)76 5042300E [email protected]
UNITED KINGDOMThetford Ltd.Unit 6Brookfields WayManvers, RotherhamS63 5DL, EnglandUnited Kingdom
T +44 (0)844 997 1960F +44 (0)844 997 1961E [email protected]
GERMANYThetford GmbHSchallbruch 14D-42781 HaanDeutschland
T +49 (0) 2129 94250F +49 (0) 2129 942525E: [email protected]
FRANCEThetford S.A.R.L.Bâtiment Le Californie11, Rue Rosa LuxembourgCS 40204 Eragny sur Oise95614 Cergy Pontoise CedexFrance
T +33 (0)1 30 37 58 23F +33 (0)1 30 37 97 67E [email protected]
ITALYThetford Italy c/o Tecma s.r.l.Via FlaminiaLoc. Castel delle Formiche05030 Otricoli (TR)Italia
T +39 0744 709071F +39 0744 719833E [email protected]
SPAIN AND PORTUGALMercè Grau SolàAgente para España y Portugalc/ Castellet, 36 bxs 2ª08800 Vilanova i la GeltrúBarcelonaEspaña
T +34 938 154 389F not availableE [email protected]
SCANDINAVIAThetford B.V.Representative Office ScandinaviaHönekullavägen 1343544 MölnlyckeSverige
T +46 (0)313363580F +46 (0)31448570E [email protected]
AUSTRALIAThetford Australia Pty. Ltd. 41 Lara WayCampbellfield VIC 3061Australia
T +61 (0)3 9358 0700F +61 (0)3 9357 7060E [email protected]
6917
10/1
118-
V07
AUSTRALIAThetford Australia Pty. Ltd. 41 Lara WayCampbellfield VIC 3061Australia
T +61 3 9358 0700F +61 3 9357 7060E [email protected]
UNITED KINGDOMThetford Ltd.Unit 6Brookfields WayManvers, RotherhamS63 5DL, EnglandUnited Kingdom
T +44 844 997 1960F +44 844 997 1961E [email protected]
GERMANYThetford GmbHSchallbruch 14D-42781 HaanDeutschland
T +49 2129 94250F +49 2129 942525E [email protected]
FRANCEThetford S.A.R.L.Parc BUROPLUS / Bâtiment 618, Boulevard de la Paix95800 CERGYFrance
T +33 1 30 37 58 23F +33 1 30 37 97 67E [email protected]
ITALYThetford Italy c/o Tecma s.r.l.Via FlaminiaLoc. Castel delle Formiche05030 Otricoli (TR)Italia
T +39 0744 709071F +39 0744 719833E [email protected]
SPAIN AND PORTUGALMercè Grau SolàAgente para España y Portugalc/ Castellet, 36 bxs 2ª08800 Vilanova i la GeltrúBarcelonaEspaña
T +34 938 154 389F not availableE [email protected]
SCANDINAVIAThetford B.V. Representative Office ScandinaviaHantverkaregatan 32D521 61 StenstorpSverige
T +46 31 336 35 80F +46 31 44 85 70E [email protected]
EUROPEAN HEADQUARTERSThetford B.V.Nijverheidsweg 29P.O. Box 1694870 AD Etten-LeurThe Netherlands
T +31 76 504 22 00F +31 76 504 23 00E [email protected]
CHINAThetford ChinaRm. 1207, Coastal Building (East Block)Haide 3rd Road, Nanshan DistrictShenzen, 518054China
T +86 755 8627 1393 F +86 755 8627 1673 E [email protected]
www.thetford.com.au
FL
WT W
FC
D
A
H HT
1
REF 288
137±6
REF
169
75±9
1
2
240VAC
12VDC-HC + 12VDC-HC COM
AC heaterNL
DC heater
Fuse 20A
WIRING DIAGRAM
WIRING PICTORIAL MODEL N3141-N3142-N3175 TYPE AUS
Power Control Module
Thermistor
Display Module
Divider heater (Double door only)
Ba�ery pack
Burner Control Module
Spark electrode
Solenoid Gas valve
12VDC heater
240VAC heater240VAC powercord
Engine Run
12VDC - LC
12VDC - HC
+- +-
Fuse 20A Fuse 2AEarth tab
Power Source Level Div. Heat.
12VDC-LC + 12VDC-LC COM
Fuse 2A
Rese�able fuse 1.1A
Solenoid gas valve
Spark electrode
Fuse 1.1A
BCMμC
5V PSU
to DM Comm.
+12V-LC+5V-DM
GND
PCM
Fan-1
Fan-1
Fan-Int
Fan-2
MODEL N3141-N3142-N3175 TYPE AUS
Switch1 2 3
Fan-2
Diode
Switch
1 2 3
Diode
Fan-1
Fan-2
Ba�.
Fuse 1.0A
Fuse 1A
3V3 PSU
μC
to PCM Comm.
+12V-LC+5V-DM
GND 4xAB
10/11xC
D EμC
5V PSU
to PCM Comm.
+12V-LC+5V-DM
GND4xF
B11xG
DE
DM-LED DM-LED+ DM-LCD
N3175
N3175
N3141, N3142
N3141N3142N3175
Fan-Int Fan-2 Fan-1
Thermoswitch-1
Thermoswitch-2
Thermoswitch-1
Thermoswitch-2
1
2
1
2
1
2
3
4
1
1
A
B
3xtorx
N3141
A B
N3142
A B