4
© 2019 Hunting. All Rights Reserved. MWD Directional Gamma Detector Module_CB October 21, 2019 www.hunting-intl.com/titan MWD Directional Detector Module (MWD-DGDM) Titan Division | Instruments 15.39 in [391 mm] 4.12 in [105 mm] 3.82 in [97 mm] 2.92 in [74 mm] 1.49 in* [38 mm] .68 in [17 mm] *Outside Dia. of O-ring Center of Opening À À Center of Crystal Center of Crystal 2 x .150 Thru All Ö.25 É .48 (TYP) 15-Pin MDM Connector 15-Socket MDM Connector 2 x 6-32 UNC É Thru All (TYP) Features Proprietary shock and vibration technology Continuous operation at 347°F (175°C) High front to back sensitivity ratio Optimized for Geosteering Low power operations, optimized for battery operations to maximize battery life MDM 15-pin connectors with industry standard through wiring allow drop-in replacement in most MWD systems Compact and rugged. High survivability in underbalanced and air drilling environments Unaffected by MWD pulser or EM transmitter electrical noise Detector design minimizes vibration and shock induced false counts Optional grounded or ungrounded (floating) chassis for EM applications Hunting’s ruggedized MWD Gamma Detector Module has been field proven in both conventional MWD and EM-MWD Geosteering applications The tool’s scintillation crystals and integral PMT assemblies are manufactured using Hunting’s proprietary assembly and shock-mounting technology. This technology provides outstanding protection against damage under higher shock and vibration drilling conditions. Low dead time for optimal pulse per angular degree detection

MWD Directional Gamma Detector Module CB

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MWD Directional Gamma Detector Module CB

© 2019 Hunting. All Rights Reserved. MWD Directional Gamma Detector Module_CB October 21, 2019

www.hunting-intl.com/titan

MWD Directional Detector Module (MWD-DGDM)Titan Division | Instruments

15.39 in[391 mm]

4.12 in[105 mm]

3.82 in[97 mm]

2.92 in[74 mm]

1.49 in*[38 mm]

.68 in[17 mm]

*Outside Dia. of O-ring

Center of OpeningÀ

À

Center of Crystal

Center of Crystal

2 x ∅ .150Thru All Ö∅

.25 É .48(TYP)

15-PinMDM Connector

15-SocketMDM Connector

2 x 6-32 UNC É Thru All (TYP)

Features

�� Proprietary shock and vibration technology

�� Continuous operation at 347°F (175°C)

�� High front to back sensitivity ratio

�� Optimized for Geosteering

�� Low power operations, optimized for battery operations to maximize battery life

�� MDM 15-pin connectors with industry standard through wiring allow drop-in replacement in most MWD systems

�� Compact and rugged. High survivability in underbalanced and air drilling environments

�� Unaffected by MWD pulser or EM transmitter electrical noise

�� Detector design minimizes vibration and shock induced false counts

�� Optional grounded or ungrounded (floating) chassis for EM applications

Hunting’s ruggedized MWD Gamma Detector Module has been field proven in both conventional MWD and EM-MWD Geosteering applications

The tool’s scintillation crystals and integral PMT assemblies are manufactured using Hunting’s proprietary assembly and shock-mounting technology. This technology provides outstanding protection against damage under higher shock and vibration drilling conditions.

Low dead time for optimal pulse per angular degree detection

Page 2: MWD Directional Gamma Detector Module CB

www.hunting-intl.com/titan

© 2019 Hunting. All Rights Reserved. MWD Directional Gamma Detector Module_CB October 21, 2019

Directional Gamma Detector Assembly

Designed especially for MWD Geosteering, the NaL(TI) Crystal’s sensitivity is directional optimized utilizing a proprietary Tungsten chassis.

†US patents: 7,115,873 7,381,957 7,485,865 7,485,851

�� PTM & Crystal mounting is extreme shock, impact and vibration resistance

�� The PMT and Crystal assembly is protected by patented shock and vibration mounting technology†

�� Can be qualified for up to 200°C (392°F) [Hamamatsu R3991AH required]

�� Patented self-healing optical coupler reduces interface light loss to improve output pulse height

�� Excellent front to back attenuation ratio.

Page 3: MWD Directional Gamma Detector Module CB

www.hunting-intl.com/titan

© 2019 Hunting. All Rights Reserved. MWD Directional Gamma Detector Module_CB October 21, 2019

Specifi cations (MWD-DGDM)

Part Number Series

MWD Directional MWD 8100-17558DG087-04-XX-A

MeasurementsThin Bed Resolution 8 in. hole diameter @ 50% points 6.8 in (173 mm)

Maximum Count Rate >10,000 cps

Count Rate Stability over Temperature ±10% 0°C to 175°C (32°F to 347°F)

Sensitivity (beryllium copper housing) 2.3 +/-0.2 API/cps

Effective Angular Window ±60°

Front/Back Count Ratio 3.5

Active NaI Crystal Size 0.84 x 4.18 in (21.3 x 106.2 mm)

Maximum Pulses/Angular Degree Approximately 28 cps/angular degree @ 60 RPM

EnvironmentalOperating Temperature Rating -40 to 175°C (-40 to 347°F)

Maximum Temperature Gradient 3°C/min (5.4°F/min)

Total Vibration (3 Axis) 30 G RMS (50 – 1000 Hz)

Shock (X-Y Axis) 1000 G (0.5 ms)

Shock (Z Axis) 1000 G (0.5 ms)

MechanicalO.D. with O-Rings (outside of o-ring) 1.485 in (37.7 mm)

Length 15.39 in (391 mm)

Electrical Connections MDM 15-pin male/female

Weight 4.84 lbs. (2.2 kg)

Back Shielding Tungsten

ElectricalOperating Voltage Range 18-38 VDC

Maximum Operating Voltage 40 VDC

Operating Current (constant power) 13 ±5 mA

Output Pulse TTL or CMOS Negative (+5VDC to 0VDC), Positive (0VDC to +5VDC)

Output Pulse Width 2 to 5 microseconds

Photomultiplier Tube Type Hamamatsu

Overall Dead Time Approximately 6 microseconds

• MWD Directional Gamma Detector Module_Tool Specifi cations• October 7, 2019

About Hunting’s Titan DivisionFor successful cased hole logging and perforating services, tool reliability, availability, and time line of delivery are essential. Hunting supplies customers worldwide with the right tools to get the job done. Our product lines include state of the art, high quality wireline and tubing conveyed perforating (TCP) gun systems, hardware and accessories, shaped charges, and electronic logging tools.

Page 4: MWD Directional Gamma Detector Module CB

www.hunting-intl.com/titan

© 2019 Hunting. All Rights Reserved. MWD Directional Gamma Detector Module_CB October 21, 2019

1

1

2

2

3

3

4

4

5

5

6

6

D D

C C

B B

A A

THE INFORMATION CONTAINED IN THIS DRAWING IS CONFIDENTIAL AND IS THE SOLE PROPERTY OF HUNTING ENERGY SERVICES. ANY DISCLOSURE OR REPRODUCTION INPART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF HUNTING IS PROHIBITED. ©Copyright 2011, Hunting, All rights reserved

1/14/19

Drawn

Engr

Dwg. No.Rev.

TitleHuntingP.O. Box 2316Pampa, Tx. 79066

Date:MCBRIDE

PROCTOR

A

WIRING DIAGRAMTENSOR STYLE MWDGAMMA RAY

026E17A0

Date

7/8/08Approved

RANSOMDate

7/8/13

Sheet: 1 OF 1

PCB No. NAASSY No. NA

123456789101112131415

123456789101112131415

PMT

BLKREDYELYEL

REDBLK

TP1 TP2

TP4

TP5

TP6

TP8

TP9

TP10

TP1

TP2

TP4

TP5

TP6

TP11

TP4

+30V INPUT

+5V REF

HIGH VOLTAGEC140.1 UF

+5V REF

ORANGE

BLACK

PURPLE

CHASSIS GROUND

WHITE/ORANGE

BLACK

WHITE

YELLOW

RED

BLACK

GND FOR INPUT PLUG

YEL FROM PMT

RED FROM PMT

BLK FROM PMT

TOP PLUG*E2100-MR15P-26E5-18.0 E2100-MR15S-26E5-18.0

BOTTOM PLUG*

*SEE ASSEMBLY DRAWING 8100-17558SH087-04-XX FOR PLUG ORIENTATION.PROPER ORIENTATION OF PLUGS WILL RESULT IN CROSSED WIRES UNDER THE AMP/DISC BOARD

SCHEM: 026S17AAPC BOARD: 8100-PCB4-175-1PC ASSY: 8100-17558S-1-96

SCHEM: 026S17AHPC BOARD: 8100-PCB4-175-2-CPC ASSY: 8100-17558S-2-C-96

TENSOR MWD BUS SIGNALSPIN 1 BLK - GNDPIN 2 BRN - BATT 1PIN 3 RED - BATT 2PIN 4 ORG - BATT BUSPIN 5 YEL - Tx RxPIN 6 GRN - PULSER CONTROLPIN 7 BLU - FLOWPIN 8 VIO - GAMMAPIN 9 GRY - MODE 1PIN 10 WHT - MODE 2PIN 11 WHT/BLK - NCPIN 12 WHT/BRN - NCPIN 13 WHT/RED - NCPIN 14 WHT/ORG - NCPIN 15 WHT/YEL - NC

ByRev. DateECO Record Eng.TP 7/8/08GM01 ECO 517 & 441

ByRev. DateECO Record Eng.TP 10/13/08GM02 WIRE DIAGRAM

ByRev. DateECO Record Eng.SL 1/14/09AH/ADC03 ECO 609 & 518

ByRev. DateECO Record Eng.TP 7/8/13ADCA ECO 1697

TP12

JUMPER TP12 TO TP10TO CONNECT CHGND

TO BOARD GND

ByRev. DateECO Record Eng.TP 4/23/15ADCA ADDED NOTE; ADDED TP12

026E17A0 Rev. A - Wiring Diagram

Pin 1 (Black)

Top End MDM Connection Bottom End MDM ConnectionPin 1 (Black)