“Innovative, Continuous, Reliable Ideas”
MSFX-Mikron Spinal Stabilisation Cervical Anterior
Plate
IntroductionThe MSFX-Mikron Spinal Stabilisation Cervical Anterior Plate System provides a versatile system of implants and instruments to accommodate the needs and individual preferences of surgeons.
The system offers optimal visualization and adapts to the anatomy of the patient.
The MSFX-Mikron Spinal Stabilisation Cervical Anterior Plate System is designed for use in a variable, constrained, or hybrid screw configuration.
Features&Benefits
A self-locking mechanism slides over screw heads after final tightening. Screw heads go below the mechanism and final tightening provides anti-backout through the self-locking system.
MSFX Cervical Plate is one of the lowest profile plating system. Its thickness is only 1,8 mm.
A full range of screws and cervical plates cover multiple indications while filling the surgeons habits.
L
Dimensions
L
MSFX-Mikron Spinal StabilisationCervical Anterior Plate Device Listing
Ref# Dimensions
Cervical Anterior Plate
MSFX-CAPXX
L: 17, 20, 25, 30mm(LVL1)L: 33, 36, 40, 45, 50mm(LVL2)L: 60, 70, 80mm(LVL3)L: 90mm(LVL4)
Cervical Anterior Plate Screw
MSFX-CAPSXX Ø4.0 L: (12, 14, 16, 18, 20)mm
MSFX-CAPSRXX Ø4.5 L: (12, 14, 16, 18, 20)mm
>> https://www.mikronmakina.com
>> https://www.msfx.com.tr
Sterilization Box For Cervical Plate Instruments Set Item No:MACPS-0001
Sterilization Box For Cervical Plate Instruments Set Item No:MACPS-0001
Cervical Plate & Screw Implant Box Item No:MACPS-00012
Cervical Plate Screw HolderItem No:MACPS-0002
Cervical Plate Drill 2,4mmItem No:MACPS-0003
Cervical Plate Drill 2,7mmItem No: MACPS-0004
Cervical Plate Screw HolderItem No:MACPS-0005
Cervical Plate LockerItem No:MACPS-0006
Cervical Plate Drill Guide Item No:MACPS-0007
Cervical Plate Bender Item No:MACPS-0008
Cervical Plate HolderItem No:MACPS-0009
Cervical Screw Tap Diameter 4,0mm Item No:MACPS-00011Cervical Screw Tap Diameter 3,5mm
Item No:MACPS-0010
Indications for UseThe MSFX-Mikron Spinal Stabilisation Cervical Anterior Plate System is indicated for stabilization of the cervical spine from C2 to C7 employing unicortical screw fixation at the anterior face of the vertebral bodies.
Specific clinical indications for anterior plating include instability caused by trauma or instability associated with:
* correction of cervical lordosis and kyphosis deformity, * pseudoarthosis as a result of previously failed cervical spine surgery, * major reconstructive surgery for primary tumors or metastatic ma-lignant tumors of the cervical spine; * single or multiple level corpectomy in advanced degenerative disc disease, spinal canal stenosis and cervical myelopathy.
>> https://www.mikronmakina.com
>> https://www.msfx.com.tr
Instruments Set
İvedik OSB Ağaçişleri San.Sit. 1372.Sk. No: 31
06378-Yenimahalle-ANKARA/TURKEY
Dağyaka Mah. Dağyaka Cad. No:38
06980-Kahramankazan-ANKARA/TURKEY
+90 312 395 17 00 / +90 312 802 00 66
+90 312 395 87 29
mikron makinaSANAYI VE TICARET LIMITED SIRKETI
“Innovative, Continuous, Reliable Ideas”
https://www.mikronmakina.comBRO4-CAP-Rev.2-17.11.19 https://www.msfx.com.tr