22
VSZ - Mechelen Boor zaag apparatuur Christophe Hannon Dirk Perreman 7 december 2017

Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

VSZ - Mechelen

Boor zaag apparatuur

Christophe HannonDirk Perreman

7 december 2017

Page 2: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Power = Diversiteit

Page 3: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Diversiteit

- Prothese chirurgie (heup en knie)- Trauma chirurgie- Hand-voet-elleboog chirurgie- Koppelstukken- Pneumatisch aangedreven- Electrisch aangedreven- Batterij aangedreven- Niet- steriel en steriele batterijen

Page 4: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Historie

- Handbediening

- Pneumatische prothese (’50,’60), trauma en mini motoren

- Electrische prothese (‘90), trauma en mini motoren

- Batterij prothese (2002), trauma en mini motoren

- Handmatige reiniging

- Machinale reiniging

Page 5: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

The Cleaning Basics-Hall 50(voorbeeld grote motor)

Before we review the cleaning instructions in detail, let’s review a few keypoints that should always be followed during the cleaning process.

Clean instruments within 30 minutes after use to minimize the potential forblood and debris drying.

A neutral pH detergent, less than pH of 10.5, should be used to preventcorrosion.

Page 6: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

The Cleaning Basics-Hall 50

Never clean equipment with bleach, chlorine-based detergents, liquid or chemical disinfectants, or any products containing sodium hydroxide (suchas, INSTRU-KLENZ or Buell Cleaner). These products degrade theanodized aluminum coating and may result in reduced handpiece reliability.

Do not lubricate any handpieces or attachments (only if needed).

Page 7: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

The Cleaning Basics-Hall 50

•Do not submerge attachments. Although Hall 50 handpieces are IPX6 & IPX8 rated, it is recommended not to submerge the handpieces in water.•All collets should be in the open position for cleaning and sterilization.•Batteries, attachments and cutting tools should be detached from thehandpieces prior to cleaning.

Now, let us begin the cleaning process……

Page 8: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging handstukken

•Hall 50 handpieces are suitable for use in washer/sanitizers.•Hall 50 handpieces have an ingress protection rating of IPX6 and IPX8 toensure the prevention of ingress of fluids during use and cleaning.

Page 9: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging hanstukken

Under running tap water, remove all traces of blood and debris.Although Hall 50 handpieces are IPX6 & IPX8 rated, it is recommended notto submerge the handpieces in water.

Ensure all collet mechanisms are in the open position

Page 10: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging handstukken

•Load handpieces& attachments in the washer/sanitizer.•Use approved solutions for cleaning. It is recommended to use a neutralpH cleaner.

•Operate washer/sanitizer according to machine manufacturer’s instructions& specifications.•A dry cycle is recommended but not required.

Page 11: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging handstukken

If you do not use a dry cycle, then gently shake the equipment free of water and wipe the surfaces with a clean, lint-free towel.

Inspect device prior to sterilization.Functional checks should be performed where possible. Mating devicesshould be checked for proper assembly.

Page 12: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Sterilisatie

All equipment should be thoroughly cleaned prior tosterilization. Recommended sterilization exposure times witha Sterilization Tray are as follows.

Method: SteamCycle: Pre-VacuumTemperature: 134°C 137° CExposure: 3-18 minutesDry Cycle: 20- 45 minutes

Page 13: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging steriele batterij

Before we review the cleaning instructions in detail, let’s review a few keypoints that should always be followed during the cleaning process.•Clean instruments within 30 minutes after use to minimize the potential forblood and debris drying. A neutral pH detergent, less than pH of 10.5, should be used to prevent corrosion.•NOTE: Enzymatic humectant sprays and aerosols that retain moisture on soiled instruments can cause corrosion of the battery contacts.Avoid their use on batteries.

Page 14: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging steriele batterij

Under running water or using a dampened lint-free cloth, remove all tracesof blood and debris.

Page 15: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Load the battery in the trayEnsure proper orientation of the battery. Contacts must not face down.

Page 16: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging steriele batterij

•Use approved solutions for cleaning. It is recommended to use a neutralpH cleaner.

•Operate washer/sanitizer according to machine manufacturer’s instructions& specifications.•A dry cycle is recommended but not required.

Page 17: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging steriele batterij

Following the cleaning process, remove the batteries from the tray.Dry the battery with a clean, lint-free towel.Completely dry the contacts to prevent corrosion.

Page 18: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Machinale reiniging steriele batterij

Once a week, clean the metal contact points on the battery. Use a cottonswab dampened with a metal approved, non-abrasive cleaning product.Load the batteries on the battery charger and charge to 100%. Once a full charge is indicated, batteries can then be sterilized.

Page 19: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Sterilisatie steriele batterij

Method: SteamCycle: Pre-VacuumTemperature: 134°C - 137° CExposure: 3-18* minutesDry Cycle: 20- 45* minutes

* Exceeding maximum exposure and dry times may result in lithium batteryend of life

Page 20: Motoren dos and don'ts - Vereniging sterilisatie · Power = Diversiteit. Committed to enhancing patient outcomes through innovative solutions. Diversiteit - Prothesechirurgie(heupenknie)

Committed to enhancing patient outcomes through innovative solutions.

Tijdsdruk!!

Het gebruik van een handstuk of hulpstuk dat/die niet volledig afgekoeld en droog is, kan de prestatie en/of betrouwbaarheid verminderen.