14
30950 Corral Drive, Suite B, Coarsegold, CA 93614 1-(800) 45-ALARM 1-(800)-452-5276 • Fax (559) 642-2699 www.SecurityProductsInc.com [email protected] Monitor 3000 Installation and Operations Manual

Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

30950 Corral Drive, Suite B, Coarsegold, CA 936141-(800) 45-ALARM

1-(800)-452-5276 • Fax (559) 642-2699www.SecurityProductsInc.com [email protected]

Monitor 3000Installation and

Operations Manual

Page 2: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

2 • Monitor 3000 REV. 20 MAY 2011

Product Information

Specifications for the Monitor 3000• Power requirements ............................ 120V A.C., 50/60 cycle, 12 watts

• Dimensions ........................................... 8-3/8” H x 7-3/8” W x 3-3/4” D

• Weight ................................................... 5-1/2 lbs

• Sound pressure level ........................... Approx 100 Decibels (at 2 meters)

• Manufactured in the United States of America (Patent # 4920333)

Optional Accessories Offered

Note: The options above are additional items, and are offered as enhancements to the standard equipment and are for variations in application which might not be needed.

Other options and details of varying applications are being developed in a continuing effort to meet customer’s needs.

Please call Security Products, Inc. for more information at 1-800-45-ALARM.

• External Siren

• Additional Magnetic Sensors

• In-Frame Magnetic Sensors

• Additional Alarm Access Door Keys

• In-Wall Housing & Finishing Frame

Page 3: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 3REV. 20 MAY 2011

The Monitor 3000 Checklist

The Monitor 3000 is shipped with the following items: 2 Monitor 3000 Door Access Keys

1 2-volt Power Supply with 12 feet of 2-conductor 18-gauge zip-cord

1 Doorjamb Package containing:

1 Magnetic Contact Switch

4 Mounting Screws (for magnet and switch)

1 12-foot 22-gauge 2-conductor wire

4 Wallboard anchors for mounting the alarm unit onto hollow walls.

4 Wood screws for mounting the alarm unit onto wood surfaces.

1 Monitor 3000 Installation & Operations Manual

To assure proper and effective operation of your new Monitor 3000 system, Security Products, Inc.

recommends that the system be installed by a qualified technician such as an electrician or alarm installer. No one should attempt to install the system until they have

read and understand these instructions completely.

Page 4: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

4 • Monitor 3000 REV. 20 MAY 2011

Alarm LocationSelecting a mounting location is extremely important for the long-term use of the Monitor 3000. A preferable location is one that is close to the door to be monitored, at eye level, and to the side of the door on which you plan to install the door contact switch. A location away from water and one that will not interfere with personnel and customer traffic is recommended. DO NOT install the Monitor 3000 in areas of extreme temperatures.

Mounting The AlarmIt is most important that the alarm be mounted securely at the location you have chosen. The four holes in the rear of the Monitor 3000 are for mounting purposes. The Monitor 3000 should be mounted level using all four mounting holes. Use the Alarm Unit as a template. Mark the wall for drilling. Appropriate fastening hardware such as wood screws, plaster anchors or toggle bolts should be used, depending on the type of surface onto which the Monitor 3000 is to be mounted.

Install the Monitor 3000 using only the top two screws at this time, and only insert these loosely, as the Monitor 3000 will have to be removed for connection of external wiring.

Page 5: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 5REV. 20 MAY 2011

Magnetic Switch Installation

IMPORTANT: The writing on the sensor and the magnet must run the same direction.

1) With a pen or pencil use the sensor to mark drill holes on the inside lip of the door frame as close to the door as possible on the handle side, not the hinge side of the door.

2) Drill the two sensor holes with a 1/8” drill.

3) Mount the sensor to the door frame and attach the two wires to the “door sensor” terminals in the alarm.

4) With the sensor mounted, place the magnet on the door so there is approximately a ¼’’ gap between them.

5) Drill holes and mount the magnet to the door.

SENSOR

APPROXIMATELY 1/4" GAP

MAGNET

EXHIBIT 1

DOOR

DOOR FRAME SIDE VIEW

EXHIBIT 2

Page 6: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

6 • Monitor 3000 REV. 20 MAY 2011

Routing Switch WiresWire should be placed inside the wall or secured neatly along the door frame molding to minimize the possibility of damage.

Route the wire inside the wall or dress it along molding and feed

through the opening in the rear of the Monitor 3000.

Connect the wires to the Connection Panel as shown. Connect either wire to screws marked Door Sensor.

THESE WIRES ARE FACTORY INSTALLED

DO NOT LOOSEN UPPER SCREWS

CONNECTION PANEL (INSIDE THE ALARM)

JACKETED WIRES TO DOOR SWITCH

MAKE SURE ALL SCREW CONNECTIONS ARE TIGHT

Page 7: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 7REV. 20 MAY 2011

Multi-Door InstallationTwo or more doors can be wired to the Monitor 3000 at the same time. The doors must be wired in series as shown.

Connecting Power Supply to the Monitor

THESE WIRES ARE FACTORY INSTALLED

DO NOT LOOSEN UPPER SCREWS

POSITIVE WIRE IS MARKED POS

NEGATIVE WIRE IS MARKED NEG

MAKE SURE ALL SCREW CONNECTIONS ARE

TIGHT

DOOR SWITCH

2-CONDUCTOR CORD TO POWER SUPPLY

CONNECTION PANEL (INSIDE THE ALARM)

Inside The Monitor - Doors are wired in series, One wire from each door spliced together. The other two

are connected to the screws on the “connection panel“ labeled “Door Sensor“

FROM THE TWO DOORS

DOOR #2 FARTHEST FROM MONITOR

DOOR #1 CLOSEST TO MONITOR

TO THE MONITOR

Page 8: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

8 • Monitor 3000 REV. 20 MAY 2011

Installing the Options*

* Must be ordered in addition to the basic Monitor 3000.

External SirenIn some circumstances, it may be desirable to have a siren at some location away from the Monitor 3000 itself. Located on the connection panel inside the Monitor 3000 are terminals for connecting an External Siren. It is important to note that the siren must be connected with the POSitive (+) and the NEGative (–) wires connected as indicated below.

Other OptionsNeeds and circumstances of our customers can vary greatly, and we at Security Products, Inc. are eager to “customize” to meet your special needs. Please call Security Products, Inc. at 1-800-45-ALARM with any special requests you might have.

OPTIONAL EXTERNAL SIREN*

OPTIONAL BACK DOORBELL*

JACKETED WIRES TO DOOR SWITCH

2-CONDUCTOR CORD TO POWER SUPPLY

Connecting the options• External Siren

Page 9: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 9REV. 20 MAY 2011

Choosing A Power Outlet

Locate the nearest INDOOR 120 volt power outlet. The power outlet should not be located near the floor. These outlets are exposed to high traffic, delivery vehicles, and excessive moisture (damage to power supply and surge protector many occur). Make sure the power outlet of choice has 24 hour constant power and is not shut off during different hours of the day.

Routing the Wires

Routing and installing the wire should always be done in the most secure and inconspicuous way possible. In new construction and whenever else possible the wire should be routed behind the walls or in the attic. If the wires cannot be routed through the walls or in the attic and surface wiring is required, use wire molding or conduit to secure and protect these wires.

Connecting the Wires

Insert the wires through the hole in the rear of The Monitor. Connect the wire marked positive to the first screw on the far left marked 12V positive. Connect the wire marked negative to the second screw from the left marked negative.

CAUTION- The wires marked positive and negative must be hooked up correctly.

Powering and Testing the System Continued:

Once you have power to the system do the following to arm and activate the system: First move the system enable toggle switch, located on the circuit board, to the down (ON) position (this will arm the system.) Close and lock the alarm box door. The system is now operational.

Note: The Monitor 3000 alarm box is armed and must be closed and locked to operate correctly. If the door is left open, the alarm will sound.

Know your Fire Safety Laws ...THE MONITOR 3000

IS INTENDED TO BE INSTALLED ON DOORS COMPLYING WITH

LOCAL, STATE, AND FEDERAL FIRE SAFETY LAWS.

Page 10: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

10 • Monitor 3000 REV. 20 MAY 2011

Operating the System:

With the time and volume adjusted to their preferred settings the alarm will operate as follows. Any door linked to the system can be opened and remain open w/o alarm for the allotted time. If the door is left opened past the allotted time the alarm will sound. The door must be closed to silence the alarm and reset the system. Once the system has been reset the door can be reopened w/o alarm.

Adjusting the Volume:

To adjust the volume, locate the Hi/Lo switch located on the siren. For high volume, flip the switch to the left. For low volume flip the switch to the right.

Adjusting the Time:

To adjust the time the door may be open, move the Dip switch (number 2)to the desired position. Moving the switch to the left will operate the timer in seconds. Moving it to the right will operate the timer in minutes. Once the switch has been set to the desired position, then use the adjustment wheel to set the desired time.

Timer AdjustmentWheel

Dip Switch (Number 2)

Page 11: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 11REV. 20 MAY 2011

Power Supply

Remove the existing center screw from the wall plate at a 120-volt outlet. Plug the Power Supply into the 120-volt outlet and run the long screw through the tab on the Power Supply, threading into the center hole of the wall plate. Tighten until snug — DO NOT OVERTIGHTEN.

Please select a 120-volt outlet that is in a safe location where delivery carts and water cannot damage it, preferably above eye level.

WALL OUTLET

POWER SUPPLY - SURGE PROTECTOR

POWER TO MONITOR

LONG SCREW

Page 12: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

12 • Monitor 3000 REV. 20 MAY 2011

Monitor 3000 Limited Warranty

The Monitor 3000 is warranted against defects in material and workmanship under normal use and conditions for a period of six (6) months from date of purchase. The Monitor 3000 is also warranted for an extended six (6) month period for a total of one (1) year from date of purchase against defects in materials and workmanship in the main circuit board. The Monitor 3000 must be purchased new from Security Products, Inc. or an authorized dealer. Warranty does not cover shipping or transportation costs. Nor does it cover products that have been subjected to misuse, negligence, abuse, or accidental damage. Nor does it cover products damaged due to improper installation or failure to follow operating instructions provided with the product. Nor does it cover products that have been repaired or altered by anyone other than Security Products, Inc. or its authorized representatives. This warranty is non-transferable and applies only to the original purchaser. Under no circumstances shall Security Products, Inc. be liable for any loss or damages, direct or indirect, incidental, special, or consequential, arising out of, or in connection with, the use of this product. Except as provided herein, Security Products, Inc. makes no warranties, expressed or implied, including warranties or merchantability and fitness for a particular purpose. Some states do not permit limitation(s) or exclusion(s) or implied warranties. Therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. The warranty gives you specific legal rights and you may also have rights that vary from state to state.

Page 13: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

Installation and Operations Manual • 13REV. 20 MAY 2011

“We Stand Behind What We Sell!”

Simply contact Security Products, Inc. TOLL FREE at 1-800-45-ALARM. Often times a problem can be solved over the phone, and your Monitor 3000 can be back in service within minutes.The parts inside the Monitor 3000 are modular. If additional repair is required, simply unplug and return the defective part along with the original sales invoice to Security Products, Inc. The defective part must be returned for the warranty to be valid.

Made with Pride in the U.S.A.

Page 14: Monitor 3000 Installation and Operations Manual · 8 • Monitor 3000 REV. 20 MAY 2011 Installing the Options* * Must be ordered in addition to the basic Monitor 3000. External Siren

14 • Monitor 3000 REV. 20 MAY 2011

PLEASE BE SURE TO LEAVE THE MANUALS AND KEYS TO THE MONITOR

ALARM WITH THE GENERAL MANAGER OR THE MANAGER ON DUTY WHEN YOU HAVE

FINISHED YOUR INSTALLATION.

PLEASE HAVE THE MANAGER CALL 1-(800)-452-5276 UPON COMPLETION OF

THIS INSTALLATION TO DISCUSS KEY CONTROL AND SYSTEM OPERATION.

THANK YOU