1
Sensor Type Solid State Metal Oxide Semiconductor Measurement Range 0-10 ppm up to 0-10,000ppm Higher ranges available on request Accuracy/Repeatability ±10% of reading or ±2.5% of range whichever is greater Response/Clearing Time T50 <90 seconds T80 <4 minutes Max output to over-range gas: <10 seconds Operating Temperature Range -40°F to +167°F; -40°C to +75°C Operating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psig Outputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 amps Power Input 117/220 VAC 22-24 VDC Electrical Classification Explosion proof Class 1, Division 1, Groups B, C, D Sensor Life/Warranty Sensor: 10 year conditional warranty Transmitter: 2 year warranty Analyzer Weight 80 lbs. Shipping Weight 140 lbs Dimensions 29" x 29" x 8" NOTE: Sample conditioning requirements are handled separately. Detcon Model series 1000-H2S process analyzers provide continuous, real-time measurement of H2S concentrations in natural gas pipelines, tail gas lines, SRU overhead gas lines, as well as other applications. Available ranges are from 0-10 ppm up to 0-10,000 ppm (1%). Higher ranges are available on request. The system can be provided with manual calibration or with microprocessor-controlled automatic calibration. Both designs employ Detcon’s proprietary solid state MOS sensor element with a ten-year conditional warranty. The analyzer features a microprocessor-based signal-conditioning transmitter with local digital display, fault supervision, calibration mode indicator, alarm relays and an RS-485 serial port. The instrument package is rated for use in electrically classified areas: Class I; Division 1; Groups B, C, and D. Line power, battery and solar powered models are available. detcon inc. SPECIFICATIONS DESCRIPTION Toll Free: 888-367-4286 Phone: 281-367-4100 Fax: 281-292-2860 http://www.detcon.com e-mail: [email protected] Hydrogen Sulfide Process Analyzer Model 1000-H2S Natural Gas Pipelines Tail Gas Lines SRU Overhead Gas Lines APPLICATIONS

Model 1000-H2S Process Analyzer Hydrogen Sulfide · Detcon Model series 1000-H2S process analyzers provide continuous, real-time measurement of H2S concentrations in natural gas pipelines,

  • Upload
    hadiep

  • View
    228

  • Download
    1

Embed Size (px)

Citation preview

Sensor Type Solid State Metal Oxide SemiconductorMeasurement Range 0-10 ppm up to 0-10,000ppm Higher ranges available on requestAccuracy/Repeatability ±10% of reading or ±2.5% of range whichever is greaterResponse/Clearing Time T50 <90 seconds T80 <4 minutes Max output to over-range gas: <10 secondsOperating Temperature Range -40°F to +167°F; -40°C to +75°COperating Pressure Requirements Inlet: 10 ±2 psig Vent: Atmospheric ±1 psigOutputs Linear 4-20 mA DC RS-485 Modbus™ 3 Relays (alarm 1, alarm 2, & fault) Contacts rated 5 ampsPower Input 117/220 VAC 22-24 VDCElectrical Classification Explosion proof Class 1, Division 1, Groups B, C, DSensor Life/Warranty Sensor: 10 year conditional warranty Transmitter: 2 year warrantyAnalyzer Weight 80 lbs.Shipping Weight 140 lbsDimensions 29" x 29" x 8"NOTE: Sample conditioning requirementsare handled separately.

Detcon Model series 1000-H2S process analyzers providecontinuous, real-time measurement of H2S concentrations innatural gas pipelines, tail gas lines, SRU overhead gas lines, aswell as other applications. Available ranges are from 0-10 ppmup to 0-10,000 ppm (1%). Higher ranges are available on request.The system can be provided with manual calibration or withmicroprocessor-controlled automatic calibration. Both designsemploy Detcon’s proprietary solid state MOS sensor elementwith a ten-year conditional warranty. The analyzer features amicroprocessor-based signal-conditioning transmitter with localdigital display, fault supervision, calibration mode indicator,alarm relays and an RS-485 serial port. The instrument packageis rated for use in electrically classified areas: Class I; Division1; Groups B, C, and D. Line power, battery and solar poweredmodels are available.

detcon inc.

SPECIFICATIONS

DESCRIPTION

Toll Free: 888-367-4286Phone: 281-367-4100Fax: 281-292-2860http://www.detcon.come-mail: [email protected]

Hydrogen SulfideProcess AnalyzerModel 1000-H2S

� Natural Gas Pipelines� Tail Gas Lines� SRU Overhead Gas Lines

APPLICATIONS