16
mini CORI-FLOW® Meters ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 1-Sep-15 Mass Flow Meter for Liquid and Gas Partnr. Model Price weldadapter / Face Seal male adapter 7.11.132 / 7.11.133 M12 5,579 $ * 7.11.055 / 7.11.056 M13 4,999 $ * 7.11.101 / 7.11.102 M14 4,999 $ * 7.11.314 M15 5,838 $ * price incl. 2 kg massblock + dampeners (for M12, M13 and M14) ; instrument mounted on the mass block. (if mass block is not needed deduct $102 from the above price) additional price for 4 kg massblock + dampeners instead of 2 kg : $83 Extra charge for ATEX Cat.3 for Zone 2 hazardous areas (Classification: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc) 172 $ PC-board A RS-232, analog I/O (nc) controller-function standard B RS-232, analog I/O (no) controller-function standard D RS-232, analog I/O, DeviceNet (nc) controller-function 208 $ E RS-232, analog I/O, DeviceNet (no) controller-function 208 $ M RS-232, analog I/O, ModBus (nc) controller-function 173 $ N RS-232, analog I/O, ModBus (no) controller-function 173 $ P RS-232, analog I/O, Profibus-DP (nc) controller-function 219 $ Q RS-232, analog I/O, Profibus-DP (no) controller-function 219 $ R RS-232, analog I/O, Flow-Bus (nc) controller-function 173 $ S RS-232, analog I/O, Flow-Bus (no) controller-function 173 $ X RS-232, analog I/O, additional an./dig. I/O* (nc) controller-function on request * Y RS-232, analog I/O, additional an./dig. I/O* (no) controller-function on request * * not suitable for use in ATEX Cat.3 for Zone 2 hazardous areas Output A 0...5 V / 0…5 V or digital: 0…100% standard B 0…10 V / 0..10 V or digital: 0…100% standard F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard Supply Voltage D + 15..24Vdc standard Connections (In/Out) 11 1/8" OD Compression Type standard 22 1/4" OD Compression Type standard 33 6 mm OD Compression Type standard 44 12 mm OD Compression Type * (see note) 126 $ 55 1/2" OD Compression Type * (see note) 145 $ 77 1/4" Face Seal Female 65 $ 88 1/4" Face Seal Male standard 99 other on request Internal Seals 0 None (metal sealed) standard Wetted Material S SS316 standard H Hastelloy-C22 (only M12, M13 and M14, connections -11-, -22-, -33-) 2,703 $ ** for M12, M13 (and M14) not recommended due to size, however when ordered on instruments i.c.w. mass block, the use of 2.20.839 is required. Series M12, M13, M14, M15 1 - 50 g/h 100 g/h 1000 g/h $ US 0.1 - 5 g/h 0.3 - 30 kg/h 3 - 300 kg/h 0.030 - 1 kg/h 10 kg/h 100 kg/h 0.2 - 5 kg/h Maximum flow range 2 - 200 g/h 20 - 2000 g/h Nominal flow: Mininum flow range Bronkhorst USA Inc. CONFIDENTIAL Prices $US 1 SEP 2015

mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

  • Upload
    leque

  • View
    506

  • Download
    6

Embed Size (px)

Citation preview

Page 1: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

mini CORI-FLOW® Meters

ATEX Cat.3 for Zone 2 hazardous areas (optionally)

Price-list 2015

1-Sep-15

Mass Flow Meter for Liquid and GasPartnr. Model Price

weldadapter / Face Seal male adapter

7.11.132 / 7.11.133 M12 5,579$ *

7.11.055 / 7.11.056 M13 4,999$ *

7.11.101 / 7.11.102 M14 4,999$ *

7.11.314 M15 5,838$

* price incl. 2 kg massblock + dampeners (for M12, M13 and M14) ; instrument mounted on the mass block. (if mass block is not needed deduct $102 from the above price)

additional price for 4 kg massblock + dampeners instead of 2 kg : $83

Extra charge for ATEX Cat.3 for Zone 2 hazardous areas (Classification: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc) 172$

PC-boardA RS-232, analog I/O (nc) controller-function standard

B RS-232, analog I/O (no) controller-function standard

D RS-232, analog I/O, DeviceNet (nc) controller-function 208$

E RS-232, analog I/O, DeviceNet (no) controller-function 208$

M RS-232, analog I/O, ModBus (nc) controller-function 173$

N RS-232, analog I/O, ModBus (no) controller-function 173$

P RS-232, analog I/O, Profibus-DP (nc) controller-function 219$

Q RS-232, analog I/O, Profibus-DP (no) controller-function 219$

R RS-232, analog I/O, Flow-Bus (nc) controller-function 173$

S RS-232, analog I/O, Flow-Bus (no) controller-function 173$

X RS-232, analog I/O, additional an./dig. I/O* (nc) controller-function on request *Y RS-232, analog I/O, additional an./dig. I/O* (no) controller-function on request *

* not suitable for use in ATEX Cat.3 for Zone 2 hazardous areas

OutputA 0...5 V / 0…5 V or digital: 0…100% standard

B 0…10 V / 0..10 V or digital: 0…100% standard

F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard

G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard

Supply VoltageD + 15..24Vdc standard

Connections (In/Out)11 1/8" OD Compression Type standard

22 1/4" OD Compression Type standard

33 6 mm OD Compression Type standard

44 12 mm OD Compression Type * (see note) 126$

55 1/2" OD Compression Type * (see note) 145$

77 1/4" Face Seal Female 65$

88 1/4" Face Seal Male standard

99 other on request

Internal Seals0 None (metal sealed) standard

Wetted MaterialS SS316 standard

H Hastelloy-C22 (only M12, M13 and M14, connections -11-, -22-, -33-) 2,703$

** for M12, M13 (and M14) not recommended due to size, however when ordered on instruments i.c.w. mass block, the use of 2.20.839 is required.

Series M12, M13, M14, M15

1 - 50 g/h

100 g/h

1000 g/h

$US

0.1 - 5 g/h

0.3 - 30 kg/h

3 - 300 kg/h

0.030 - 1 kg/h10 kg/h

100 kg/h 0.2 - 5 kg/h

Maximum flow range

2 - 200 g/h

20 - 2000 g/h

Nominal flow: Mininum flow range

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 2: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

mini CORI-FLOW® Controllers with integrated valvesSeries M12, M13, M14, M15ATEX Cat.3 for Zone 2 hazardous areas (optionally)

Price-list 2015

1-Sep-15

Mass Flow Controller for liquid with purge connecto r Mass Flow Controller for gas without purge connecto rPartnr. Model Minimum flow range: Price

weldadapter /Face Seal male adapter

7.11.135 / 7.11.137 M12V14I nc-valve; PN100; Kv-max = 3.4E-4 (0,2 mm) 6,594$ *

7.11.134 / 7.11.136 M12V10I nc-valve; PN100; Kv-max = 3.4E-4 (0,2 mm) 6,594$ *

7.11.134 / 7.11.136 M12V11I no-valve; PN100; Kv-max = 3.4E-4 (0,2 mm) 6,594$ *

7.11.059 / 7.11.061 M13V14I nc-valve; PN100; Kv-max = 2.4E-3 (0,37 mm) 6,013$ *

7.11.058 / 7.11.060 M13V10I nc-valve; PN100; Kv-max = 2.4E-3 (0,37 mm) 6,013$ *

7.11.058 / 7.11.060 M13V11I no-valve; PN100; Kv-max = 2.4E-3 (0,37 mm) 6,013$ *

7.11.104 / 7.11.106 M14V14I nc-valve; PN100; Kv-max = 2.4E-3 (0,37 mm) 6,013$ *

7.11.103 / 7.11.105 M14V10I nc-valve; PN100; Kv-max = 1.7E-2 (1,0 mm) 6,013$ *

7.11.103 / 7.11.105 M14V11I no-valve; PN100; Kv-max = 1.7E-2 (1,0 mm) 6,013$ *

* price incl. 2 kg massblock + dampeners (for M12, M13 and M14); instrument mounted on the mass block. (if mass block is not needed deduct $102 from the above price)

additional price for 4 kg massblock + dampeners instead of 2 kg : $83

Extra charge for ATEX Cat.3 for Zone 2 hazardous areas (Classification: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc) 172$

PC-boardA RS-232, analog I/O (nc) controller-function standard

B RS-232, analog I/O (no) controller-function standard

D RS-232, analog I/O, DeviceNet (nc) controller-function 208$

E RS-232, analog I/O, DeviceNet (no) controller-function 208$

M RS-232, analog I/O, ModBus (nc) controller-function 173$

N RS-232, analog I/O, ModBus (no) controller-function 173$

P RS-232, analog I/O, Profibus-DP (nc) controller-function 219$

Q RS-232, analog I/O, Profibus-DP (no) controller-function 219$

R RS-232, analog I/O, Flow-Bus (nc) controller-function 173$

S RS-232, analog I/O, Flow-Bus (no) controller-function 173$

X RS-232, analog I/O, additional an./dig. I/O* (nc) controller-function on request *

Y RS-232, analog I/O, additional an./dig. I/O* (no) controller-function on request *

* not suitable for use in ATEX Cat.3 for Zone 2 hazardous areas

Output / SetpointA 0...5 V / 0…5 V or digital: 0…100% standard

B 0…10 V / 0..10 V or digital: 0…100% standard

F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard

G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard

Supply VoltageD + 15..24Vdc standard

Connections (In/Out)11 1/8" OD Compression Type standard

22 1/4" OD Compression Type standard

33 6 mm OD Compression Type standard

44 12 mm OD Compression Type * (see note) 126$

55 1/2" OD Compression Type * (see note) 145$

77 1/4" Face Seal Female 65$

88 1/4" Face Seal Male standard

99 other on request

* for M12, M13 (and M14) not recommended due to size

Internal SealsV Viton on request

E EPDM on request

K Kalrez standard

Wetted MaterialS SS316 standard

** for M12, M13 (and M14) not recommended due to size, however when ordered on instruments i.c.w. mass block, the use of 2.20.839 is required.

0.6 - 30 kg/h

0.1 - 5 g/h 4 - 200 g/h

Maximum flow range:

40 - 2000 g/h

Nominal flow:

1 - 50 g/h

100 g/h

1000 g/h

$US

10 kg/h 0.030 - 1 kg/h

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 3: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

mini CORI-FLOW® Meters

Price-list 2015

1-Sep-15

Mass Flow Meter for Liquid and GasPartnr. Model Price

7.11.448 ML120V00 6,122$ *7.11.449 ML120V21 7,871$ *

* 2 kg massblock will be standard, for (ultra) low flows a 4 kg massblock is advised for optimal performance.additional price for 4 kg massblock + dampeners instead of 2 kg : EUR 52,00

PC-boardA RS-232, analog I/O (nc) controller-function (meter only) standard

B RS-232, analog I/O (no) controller-function standard

D RS-232, analog I/O, DeviceNet (nc) controller-function (meter only) 205$

E RS-232, analog I/O, DeviceNet (no) controller-function 205$

M RS-232, analog I/O, ModBus (nc) controller-function (meter only) 170$

N RS-232, analog I/O, ModBus (no) controller-function 170$

P RS-232, analog I/O, Profibus-DP (nc) controller-function (meter only) 216$

Q RS-232, analog I/O, Profibus-DP (no) controller-function 216$

R RS-232, analog I/O, Flow-Bus (nc) controller-function (meter only) 170$

S RS-232, analog I/O, Flow-Bus (no) controller-function 170$

T RS-232 and EtherCAT I/O (nc) controller-function (meter only) 369$

U RS-232 and EtherCAT I/O (no) controller-function 369$

X RS-232, analog I/O, additional an./dig. I/O (nc) controller-function (meter only) on request

Y RS-232, analog I/O, additional an./dig. I/O (no) controller-function on request

OutputA 0...5 V / 0…5 V or digital: 0…100% standard

B 0…10 V / 0..10 V or digital: 0…100% standard

F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard

G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard

Supply VoltageD + 15..24Vdc standard

Connections (In/Out)CC 1/16" OD Compression Type standard

99 other on request

Internal Seals0 none (for meters) Standard

K Kalrez (FFKM) Standard

Z Other on request

Wetted MaterialS SS316 standard

Partnr. Model Price

2.17.241 Degasser 7,723$

2.17.242 Filter 909$

2.13.214 Tubing 29$

2.17.243 Shutoff Valve 183$

2.04.522 Connector Peek external nut 1/16" 30$

2.04.313 Ferrule Peek internal ferulle groove 1/16" 19$

Series ML120

Nominal flow: Mininum flow range Maximum flow range

2-Way valve Bio w/ 1/16"

$US

Accessoires for ML120 system setup

4 channels, high pressureIsoprep filter + filter holder, 0,5 umTub Tfzl Nat 1/16x.020x1m

100 g/h 0.05 - 5 g/h 2 - 200 g/h100 g/h 0.05 - 5 g/h 2 - 200 g/h

Bronkhorst USA Inc.Confidential Prices $US 1 SEP 2015

Page 4: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

valves for (mini) CORI-FLOW® Meters

Price-list 2015

1-Sep-15

Control Valves Standard 64 BAR 100 BAR 400 BARPartnr. Type of coil Kv-max Connections Type Price Type Price Type Price

7.10.003 IP-65 NC 6.60E-02 1-2-3-8 F-011AI-IIU 974$ 7.10.004 IP-65 NO 5.00E-02 1-2-3-8 F-011AI-IIU 1,091$ 7.10.013 II 1 G/D Ex ia IIC T6 NC 4.30E-03 1-2-3-8 F-011AX-XBB- 1,299$ 7.10.014 II 1 G/D Ex ia IIC T6 NO 4.30E-03 1-2-3-8 F-011AX-XBB- 1,416$ 7.10.013 II 2 G/D Ex e mb II T4 NC 6.60E-02 1-2-3-8 F-011AX-XCB- 1,090$ 7.10.014 II 2 G/D Ex e mb II T4 NO 5.00E-02 1-2-3-8 F-011AX-XCB- 1,208$ 7.10.006 IP-65 NC KV = 4-5 F-012AI-IIU 1,877$ 7.10.015 II 1 G/D Ex ia IIC T6 NC 0,04…0,4 4-5 F-012AX-XBB- 2,200$ 7.10.015 II 2 G/D Ex e mb II T4 NC 4-5 F-012AX-XCB- 1,993$ 7.10.008 IP-65 NC KV = 4-5 F-013AI-IIU 2,536$ 7.10.016 II 1 G/D Ex ia IIC T6 NC 0,15…1,5 4-5 F-013AX-XBB- 2,861$ 7.10.016 II 2 G/D Ex e mb II T4 NC 4-5 F-013AX-XCB- 2,651$ 7.10.009 IP-65 NC KV = 1" / 25 mm. F-013BI-IIU 4,187$ 7.10.017 II 2 G/D Ex e mb II T4 NC 0,6…6,0 1" / 25 mm. F-013BX-XCB- 4,302$ 7.10.177 IP-65 NC 1-2-3-8 F-033CI-IIU- 2,313$ 7.10.178 II 1 G/D Ex ia IIC T6 NC 1-2-3-8 F-033CX-XBB- 2,638$ 7.10.178 II 2 G/D Ex e mb II T4 NC 1-2-3-8 F-033CX-XCB- 2,429$

Pressure rating 10 bar(g) Kv = Max. delta-P 5 bar(d)

7.10.011 IP-65 NC 0,03...0.3 4-5 F-004AI-IUU- 2,062$ 7.10.012 IP-65 NC 0,1...1 4-5 F-004BI-IVU- 2,727$

Extra charge for ATEX Cat.3 for Zone 2 hazardous areas (Classification: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc) in combination with ATEX cat.3 (mini) Cori incl.

included ATEX protection cover

11 - 1/8" OD Compression typeInlet / Outlet 22 - 1/4 " OD Compression typeconnector 33 - 6 mm OD Compression type

88 - 1/4" Face Seal male44 - 12 mm OD Compression type 58$ extra charge per set 55 - 1/2" OD Compression type 58$ for series F-001AI/033CI66 - 20 mm OD Compression type 290$ extra p. set for series xx3AI/AX99 - Other

Seals Standard F-011AI F-012AI F-013AI F-013BI F-033CI F-004AI F -004BI

V VITON standard standard standard standard standard standard sta ndard

E EPDM* 45$ 234$ 363$ 488$ 135$ 45$ 45$

K Kalrez 293$ 666$ 997$ 1,709$ 501$ 291$ 467$

Z Viton + Kalrez plunger 59$ 114$ 114$ on request 119$ 59$ 156$

USP class VI/FDA approved seals F-011AI F-012AI F-013A I F-013BI F-033CI F-004AI F-004BI

V VITON 114$ 227$ 227$ 254$ 227$ 159$ 191$

E EPDM* 253$ 733$ 938$ 1,181$ 576$ 324$ 374$

K Kalrez 540$ 1,209$ 1,735$ 2,867$ 946$ 517$ 893$

*) check material compatibility chart for sealing material for correct choice

For liquid applications specify:

7.11.123 C2I-IIU-xx-K 1,325$ control valve with Ind-coil, purge adapter and Kalrez seals7.01.873 C5I-ITU-xx-K 1,349$ control valve with Ind-coil and Kalrez seals

Portconnectors:pn 2.04.109, 1/8" - 1/8" 58$ pn 2.04.111, 1/2" - 1/2" 95$ pn 2.04.110, 1/4" - 1/4" 58$ pn 2.04.112, 1/4" - 1/2" 95$ pn 2.04.191, 6 mm - 6 mm 58$ pn 2.04.218, 12 mm - 12 mm 95$ pn 2.04.270, 1" - 1" 121$ pn 2.04.497, 25 mm - 25 mm 121$

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 5: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

(mounted on weld body)

Price-list 2015

1-Sep-15

Pneumatic Shut Off Valves StandardPartnr. Kv-max Connections

7.11.458 PV-01-NC-xx-V NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.458 PV-01-NC-xx-K NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.458 PV-01-NC-xx-E NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.458 PV-01-NO-xx-V NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.458 PV-01-NO-xx-K NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.458 PV-01-NO-xx-E NO 0.2 (orifice 3.5 mm) 1-2-3-8

Pilot Pneumatic Shut Off Valves StandardPartnr. Kv-max Connections

7.11.459 PV-02-NC-xx-V NC 2.00E-01 1-2-3-87.11.459 PV-02-NC-xx-K NC 2.00E-01 1-2-3-87.11.459 PV-02-NC-xx-E NC 2.00E-01 1-2-3-87.11.459 PV-02-NO-xx-V NO 8.50E-02 1-2-3-87.11.459 PV-02-NO-xx-K NO 8.50E-02 1-2-3-87.11.459 PV-02-NO-xx-E NO 8.50E-02 1-2-3-8

Pilot Pneumatic Shut Off Valves with feedback StandardPartnr. Kv-max Connections

7.11.460 PV-01-NCF-xx-V-1 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NCF-xx-K-1 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NCF-xx-E-1 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NCF-xx-V-0 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NCF-xx-K-0 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NCF-xx-E-0 NC 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-V-1 NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-K-1 NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-E-1 NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-V-0 NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-K-0 NO 0.2 (orifice 3.5 mm) 1-2-3-87.11.460 PV-01-NOF-xx-E-0 NO 0.2 (orifice 3.5 mm) 1-2-3-8

11 1/8" OD Compression typeInlet / Outlet 22 1/4" OD Compression typeconnector 33 6 mm OD Compression type

88 1/4" Face Seal male44 12 mm OD Compression type55 1/2" OD Compression type99 Other

Portconnectors:pn 2.04.109, 1/8" - 1/8" pn 2.04.111, 1/2" - 1/2"pn 2.04.110, 1/4" - 1/4" pn 2.04.112, 1/4" - 1/2"pn 2.04.191, 6 mm - 6 mm pn 2.04.218, 12 mm - 12 mm

Price

shut-off valves for (mini) CORI-FLOW® Meters

10 BARPrice

646$

840$

$US

653$

591$

754$

591$

1,277$

1,146$

1,274$

1,158$

1,057$

1,205$

1,068$

Price1,083$

1,277$

1,091$

1,083$

58$

1,091$

1,021$

1,183$

1,021$

1,021$

1,183$

1,021$

standard

standard

standard

standard

59$ 95$

58$

59$ 95$

59$ 95$

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 6: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Ex-d mini CORI-FLOW® Meters

IECEx and ATEX Zone 1

Price-list 2015

1-Sep-15

Mass Flow Meter for Liquid and GasModel Price

XM12 10,073$

XM13 9,416$

XM14 9,416$

note that for use of meters i.c.w. valves with XBB coil, the use of a barrier is required.

PC-boardA RS-232, analog I/O (nc) controller-function standard

B RS-232, analog I/O (no) controller-function standard

D RS-232, analog I/O, DeviceNet (nc) controller-function 323$

E RS-232, analog I/O, DeviceNet (no) controller-function 323$

M RS-232, analog I/O, ModBus (nc) controller-function 288$

N RS-232, analog I/O, ModBus (no) controller-function 288$

P RS-232, analog I/O, Profibus-DP (nc) controller-function 334$

Q RS-232, analog I/O, Profibus-DP (no) controller-function 334$

R RS-232, analog I/O, Flow-Bus (nc) controller-function 288$

S RS-232, analog I/O, Flow-Bus (no) controller-function 288$

X RS-232, analog I/O, additional an./dig. I/O (nc) controller-function on request

Y RS-232, analog I/O, additional an./dig. I/O (no) controller-function on request

OutputA 0...5 V / 0…5 V or digital: 0…100% standard

B 0…10 V / 0..10 V or digital: 0…100% standard

F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard

G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard

Supply VoltageD + 15..24Vdc standard

Connections (In/Out)11 1/8" OD Compression Type standard

99 other on request

Internal Seals0 None (metal sealed) standard

Wetted MaterialS SS316 standard

H Hastelloy-C22 on request

Optional package containing : Price- Integrated display (e.g. Bright) on request

- Exi output for flow rate (passive 4..20mA output)- Temperature control to prevent freezing (thermostat)

Series M12, M13, M14

10 kg/h

1 - 50 g/h

0.030 - 1 kg/h

Nominal flow:100 g/h

1000 g/h

Mininum flow range

$US

0.1 - 5 g/h

0.3 - 30 kg/h

Maximum flow range2 - 200 g/h

20 - 2000 g/h

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 7: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Mounting parts mini CORI-FLOW and CORI-FLOW series

Price-list 2015

1-Sep-15

Options for meters and controllers: Price

5.02.004 Mini Cori-Flow mounting block small for optimal accuracy, Steel; weight 2 kg, + 4 small dampeners and rubber pads 264$

+5.02.006 For use with:

M12, M13, M14 meters and controllers with:Valves: V10, V11, V14, C0, C1, F-011AI, C2, C5

max load = 56 kg

5.02.005 (Mini) Cori-Flow mounting block large for optimal accuracy, Steel; weight 4 kg, + 4 large dampeners and rubber pads 394$

+5.02.007

For use with:M12, M13, M14 meters and controllersM53, M54, M55 meters (and controllers)Valves: V10, V11, V14, C0, C1, F-011AI, C2, C5

10 kg/h M53, M54, M55 meters (and controllers)max load = 240 kg

small dampener large dampener

2.20.839 Distance part to compensate for height difference when M1x series Cori-Flow is combined with BHT valve 49$ 2.20.778 Distance part to compensate for height difference when M1x series Cori-Flow is combined with 1/4" Badger valve 33$

2.20.840 Distance part to compensate for height difference when M5x series Cori-Flow is combined with a BHT valve 64$ also for M1x instruments with 1/2" or 12 mm connections

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 8: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

CORI-FLOW® Meters

ATEX Cat.3 for Zone 2 hazardous areas (optionally)

Price-list 2015

1-Sep-15

Mass Flow Meter for LiquidPartnr. Model Model

7.01.995 M53 M53 on request

7.01.996 M54 M54 7,017$ *

7.01.997 M55 M55 7,696$ *

additional price for 4 kg massblock + dampeners on M54 / M55 : $256

Extra charge for ATEX Cat.3 for Zone 2 hazardous areas (Classification: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc) 172$

PC-boardA RS-232, analog I/O (nc) controller-function standard

B RS-232, analog I/O (no) controller-function standard

D RS-232, analog I/O, DeviceNet (nc) controller-function 208$

E RS-232, analog I/O, DeviceNet (no) controller-function 208$

M RS-232, analog I/O, ModBus (nc) controller-function 173$

N RS-232, analog I/O, ModBus (no) controller-function 173$

P RS-232, analog I/O, Profibus-DP (nc) controller-function 219$

Q RS-232, analog I/O, Profibus-DP (no) controller-function 219$

R RS-232, analog I/O, Flow-Bus (nc) controller-function 173$

S RS-232, analog I/O, Flow-Bus (no) controller-function 173$

X RS-232, analog I/O, additional an./dig. I/O (nc) controller-function on request *

Y RS-232, analog I/O, additional an./dig. I/O (no) controller-function on request *

* not suitable for use in ATEX Cat.3 for Zone 2 hazardous areas

OutputA 0...5 V / 0…5 V or digital: 0…100% standard

B 0…10 V / 0..10 V or digital: 0…100% standard

F 0...20 mA sourcing / 0…20 mA or digital: 0…100% standard

G 4...20 mA sourcing / 4…20 mA or digital: 0…100% standard

Supply VoltageD + 15..24Vdc standard

Connections (In/Out)11 1/8" OD Compression Type (not recommended due to size) standard

22 1/4" OD Compression Type standard

33 6 mm OD Compression Type standard

44 12 mm OD Compression Type (recommended at flow > 100 kg/h liquid) ** 126$

55 1/2" OD Compression Type (recommended at flow > 100 kg/h liquid) ** 145$

77 1/4" Face Seal Female 65$

88 1/4" Face Seal Male standard

99 other on request

Internal Seals0 None (metal sealed) standard

Wetted MaterialS SS316 standard

H Hastelloy-C22 (only M54) 3,374$

Options for meters : PriceRemote electronics for temperatures up to 120°C (and < 1hour up to 131°C for steam cleaning) (not for ATEX Zone II) 827$

** When ordered on instruments i.c.w. mass block, the use of 2.20.840 is required.

50 kg/h

500 kg/h

0,2 - 5 kg/h

6 - 600 kg/h

1 - 100 kg/h

(Series M53, M54, M55)

Mininum flow range Maximum flow range

0,5 - 20 kg/h

$US

5 kg/h 50 - 500 g/h 0,2 - 10 kg/h

Nominal flow:

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 9: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Actuator tests

Price-list 2015

1-Sep-15

Actuator purchased Actuator purchasedPart. Nr. and delivered by by customer

Bronkhorst Cori-Tech7.20.016 Simulation test with actuators (Actuator not sent t o factory) N.A. 256$

- Controller test with similar (simulated) actuator

- Electrical adjustments on instrument Actuator not- Instrument parameter settings for actuator control sent to - Valve cable with loose ends and labeling Bronkhorst Cori-Tech- Connection description

Note: - Actuator is to be connected in the field by the end-user- Controller settings need to be optimized at the end-user

for maximum control performance- Bronkhorst will accept no system responsibility for this combination

7.20.017 Functional test with actuators (Actuator sent to f actory) 299$ 557$

- Quick controller function test without fluid- Electrical adjustments on instrument Actuator sent to- Mechanical connections to actuator and additional hardware if possible* Bronkhorst Cori-Tech- Electrical connections to actuator- Instrument parameter settings for actuator control- System description

Note:- Controller settings need to be optimized at the end-user

for maximum control performance

7.20.018 System test with actuators (Actuator sent to facto ry) 855$ 1,113$

- Extensive controller test on fluid (test with Water or IPA for liquids; Air for gases) Actuator sent to- Electrical adjustments on instrument Bronkhorst Cori-Tech- Mechanical connections to actuator and additional hardware*- Electrical connections to actuator- Instrument parameter settings for actuator control- System description

Note:- Controller settings need to be optimized at the end-user

for maximum control performance if test could not be performed on actual fluid (only tests possible on: water, IPA or Air)

Prices are also valid for sensors not sold by Bronk horst* mechanical connections are used for testing, but will not standard be part of the shipment. In case mechanical connections should be supplied these are to be ordered separately

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 10: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

BRIGHT - Local R/C-module and Plug-in Power Supply

Price-list 2015

1-Sep-15

Partnr. Model Descirption Price7.09.202 B4 IP65 R/C module c/w mounting kit 695$

Specifications:• 1.8" colour TFT display• 4 push buttons for menu operation• RS232 communication with instrument

(Note: The RS232 connection cannot simultaneously be used for communication with a PC/Process Computer)

• Required supply voltage 15…24 Vdc• Connections: B4 (IP65): T-connector with 8-pin DIN sockets• Cable: B4: long cable with 4-pin DIN connections, length 80 cm• Mounting: All types: clip for mounting the module under variable angles

B4: additional mounting bracket for tube or wall mountingOnly for instruments in digital mode

Plug-in Power Supply (PiPS)

Partnr. Model number Descirption Price7.03.423 PiPS-IN Plug-in power supply 8DIN for industrial instruments 159$

Specifications: Suppy +15 Vdc / 1AIncl. convertor to US, UK, Australian and IEC connector

Only for instruments in digital mode

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 11: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Cables

Price-list 2015

1-Sep-15

Partnr. Description Connection Connection length Pricemeter/controller readout

7.03.187 8 x 0,25 DIN8 female D-conn. male 3m 86$

7.03.191 8 x 0,25 DIN8 female Loose end 3m 70$

7.03.540 8 x 0,25 DIN8 female Loose end 5m 78$

7.03.541 8 x 0,25 DIN8 female Loose end 10m* 97$

7.03.522 8 x 0,25 DIN8 female (ATEX) Loose end (safe area) 3m* 78$ 7.03.523 8 x 0,25 DIN8 female (ATEX) DIN8 male (safe area) 3m* 170$ 7.03.524 8 x 0,25 DIN8 female (ATEX) D-conn. male (safe area) 3m* 94$ 7.03.444 3m 170$ 7.03.508 5m 188$ 7.03.509 10m 200$ 7.03.446 3m 194$

* Prices for cables > 3 m:

Lenghts only 5, 10, 15…..per 5 meter, in between no t possible (contact factory for max. cable length)

add $5 per 1 meter for cables type "8 x 0,25"

other cables can be found in BHT pricelist

RS232 cable for use with IP65 instrumentsRS232 cable for use with IP65 instrumentsRS232 cable for use with IP65 instrumentsCable to connect (mini) Cori-Flow to valve/actuator

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 12: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Cables

Price-list 2015

1-Sep-15

Bus interface cables for industrial style instruments

Partnr. Model DEVICE-NET

7.03.319 DeviceNet Y-adapter M12 62$

7.03.320 DeviceNet Begin terminator M12 (female) 33$

7.03.321 DeviceNet End terminator M12 (male) 30$

7.03.322 DeviceNet M12 cable, length 0,3 m 40$

7.03.323 DeviceNet M12 cable, length 3 m 72$

1.09.379 DeviceNet M12 male connector 21$

1.09.380 DeviceNet M12 female connector 21$

PROFI-BUS

7.03.352 Profi-Bus M12 cable, length 0,3 m 80$

7.03.353 Profi-Bus M12 cable, length 3 m 99$

7.03.354 Profi-Bus End terminator M12 (male) 37$

7.03.476 Profi-Bus T-adapter M12 196$

1.09.418 Profi-Bus M12 female connector 43$

1.09.419 Profi-Bus M12 male connector 48$

FLOW-BUS

7.03.319 Flow-Bus Y-adapter M12 62$

7.03.321 Flow-Bus End terminator M12 (male) 30$

7.03.515 Flow-Bus Begin terminator M12 (female) 127$

7.03.322 Flow-Bus M12 cable, length 0,3 m 40$

7.03.323 Flow-Bus M12 cable, length 3 m 72$

1.09.379 Flow-Bus M12 male connector 21$

1.09.380 Flow-Bus M12 female connector 21$

7.03.452 Flow-Bus / DeviceNet M12 female- RJ45 cable, length 0.5 m 57$

7.03.347 Flow-Bus / DeviceNet M12 female- RJ45 cable, length 3 m 68$

7.03.350 Flow-Bus / DeviceNet power isolator M12 105$

7.03.357 Flow-Bus / DeviceNet M12 female to RJ45 Y-adapter 129$

7.03.358 Flow-Bus / DeviceNet M12 male- RJ45 cable, length 3 m 132$

Bus interface cables for industrial style instruments are no standard stock items

Not applicable for ATEX Cat.3 for Zone 2 hazardous areas (Class.: II 3 G Ex nA IIC T4 Gc // II 3 D Ex tc IIIC T70° C Dc)

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 13: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

Additions

Price-list 2015

1-Sep-15

Partnr.

Special Certificates7.20.004 Pressure test/leak test certificate/inspection certificate 76$

according to EN 10204/3.1 (doc.nr. 30910)7.20.005 Pressure test/leak test certificate/inspection certificate 369$

according to EN 10204/3.2 (doc.nr. 30915)7.20.006 Certificate of compliance with the order according to 76$

EN 10204/2.1 (doc.nr. 30900)7.20.007 Degreasing certificate (doc. nr. 30920) 76$ 7.20.008 Cleaning + bagging as if for O2-duty (incl. certificate) per instrument 94$ per instr.7.20.009 PED-declaration of conformity (doc. nr. 30930) if necessary free of charge7.20.010 Laboratory analysis for the wetted parts. (doc nr. 30950) 76$

This should be specified at the time of order entry. 7.20.011 Copy of VSL/NMI-certificate from calibration reference 76$ 7.20.012 Certificate of origin issued by Bronkhorst 76$ 7.20.013 Certificate of origin issued by the Chamber of Commerce 134$ 7.20.014 Data sheet Viton FDA (contact factory for the add. charge of FDA seals) free of charge7.20.015 Data sheet Kalrez FDA (contact factory for the add. charge of FDA seals) free of charge

7.20.038 Special drying procedure 80$

1.09.144 Mating connector for (mini) Cori-Flow* 30$

Instruction manualsStandard: 1 per order includedExtra : more than 1 per instrument 13$

* 1 mating connector per instrument free of charge when no cable is ordered

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 14: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

(mini) CORI-FLOW® Liquid Dosing Systems with Tuthill gear pumps

Price-list 2015

1-Sep-15

Price(excl. (mini) Cori-Flow)

DGS.11 - DGS2.3 (icw mini Cori-Flow) (1)3,452$

DGS.11 - DGS2.3 (icw (mini) Cori-Flow) (2)3,617$

(1) : only for M12, M13 and M14(2) : only for M15, M54 and M55

Liquid Dosing System consists of :* flowmeter (M12, M13, M14, M15, M54, M55) Mini-Cori with Tuthill mounted horizontally, no-by-pass* pump (with Dunkermotor 70 Watt motor; type BG45)* massblok (4 kg) + large dampeners* pump and meter mechanically connected (prepared for optional by-pass)* pump electrically connected to flowmeter

standard features :* PPS or PEEK gears and bearings (max. 60°C, see options), indicate when ordering* Material of construction : SS316* Teflon O-rings* Required power supply : + 24Vdc / 6A* Min. viscosity : 0.3 mPa.s* Max. viscosity : 2000 mPa.s* For large flows (> 50 kg/h) we advise large connection (3/8" or bigger) on inlet of pump and outlet of Cori-Flow

Vertical mounted Tuthill pump incl. by-passExamples:DGS.11PPPT2NN00000 + BG45 is a DGS.11 with PPS gears and bearings and BG45 DunkermotorDGS.19EEET2NN00000 + BG45 is a DGS.19 with PEEK gears and bearings and BG45 Dunkermotor

article nr.

options Price

- vertical mounting of Tuthill pump 80$

- Internal by-pass; 30 / 130 psig (please indicate in your order) 134$

(internal by-pass only available for SS316 pumps, high pressure by-pass only upto DGS.80)- External by-pass (swagelok metering valve) 6 mm OD compression type 2.17.155 286$

- External by-pass (swagelok metering valve) 1/4" OD compression type 2.17.154 286$

- Hastelloy on request

- Trimmed gears for higher temperature use > 60°C 76$

- Kalrez 6375 O-rings (AS022) 270$

- Viton O-rings -$

- Power supply (+ 24Vdc / max. 6 A) incl. mains cable 1.16.051 302$

- Service pack (excisting of 2 gears, 5 bearings and 3 teflon O-rings) 310$

- For liquids containing particles > 20 µm we advise to use a filter- Pumps can make high pressures when flow lines are blocked. In order to prevent burst of tubing, flow leakage and damage of gears, the use of a safety device, such as a pressure relief valve, is strongly advised- When ordering a liquid dosing system always indic ate the required system pressure, i.e. the pressure at outlet of (mini) Cori-Flow

For selection of a pump for your application you can use the Tuthill pump selector tool, which is available via the distributor login (www.bronkhorst-cori-tech.com)

(Series M12, M13, M14, M15, M54, M55)

Liquid Dosing System

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 15: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

(mini) CORI-FLOW® Liquid Dosing Systems with flanged Tuth ill gear pumps

Price-list 2015

1-Sep-15

Price(excl. (mini) Cori-Flow)

DGS.11 + DGS.19 (icw mini Cori-Flow) (1)3,759$

DGS.11 + DGS.19 (icw (mini) Cori-Flow) (2)3,924$

DGS.23 + DGS.38 (icw (mini) Cori-Flow) on request(1) : only for M12, M13 and M14(2) : only for M15, M54 and M55

Liquid Dosing System consists of :* flowmeter (M12, M13, M14, M15, M54, M55)* pump (with Dunkermotoren motor 70 Watt motor; type BG45)* massblok (4 kg) + large dampeners* pump and meter mechanically connected (prepared for optional by-pass)* pump electrically connected to flowmeter

standard features :* PPS or PEEK gears and bearings (max. 60°C, see options), indicate when ordering* Material of construction : SS316* Teflon O-rings* Required power supply : + 24Vdc / 6A* Min. viscosity : 0.3 mPa.s* Max. viscosity : 2000 mPa.s* For large flows (> 50 kg/h) we advise large connection (3/8" or bigger) on inlet of pump and outlet of Cori-Flow

Examples:DGS.11PPPTXNN00000 + BG45 is a DGS.11 with PPS gears and bearings, flanged connections and BG45 DunkermotorDGS.19EEETXNN00000 + BG45 is a DGS.19 with PEEK gears and bearings, flanged connections and BG45 Dunkermotor

article nr.

options Price

- vertical mounting of Tuthill pump 80$

- External by-pass (swagelok metering valve) 6 mm OD compression type 2.17.155 286$

- External by-pass (swagelok metering valve) 1/4" OD compression type 2.17.154 286$

- Hastelloy on request

- Trimmed gears for higher temperature use > 60°C 76$

- Kalrez 6375 O-rings (AS022) 270$

- Viton O-rings -$

- Power supply (+ 24Vdc / max. 6 A) incl. mains cable 1.16.051 302$

- Service pack (excisting of 2 gears, 5 bearings and 3 teflon O-rings) 310$

- For liquids containing particles > 20 µm we advise to use a filter- Pumps can make high pressures when flow lines are blocked. In order to prevent burst of tubing, flow leakage and damage of gears, the use of a safety device, such as a pressure relief valve, is strongly advised- When ordering a liquid dosing system always indic ate the required system pressure, i.e. the pressure at outlet of (mini) Cori-Flow

(Series M12, M13, M14,M15, M54, M55)

Liquid Dosing System

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015

Page 16: mini CORI-FLOW® Meters Series M12, M13, M14, M15 ATEX … · ATEX Cat.3 for Zone 2 hazardous areas (optionally) Price-list 2015 ... analog I/O, ModBus (nc) controller-function $

mini CORI-FLOW® Liquid Dosing Systems with KNF diaphrag m pumps

Price-list 2015

1-Sep-15

PriceDosing unit(excl. mini Cori-Flow)

NF1.10 PML7175 1,771$

Dosing system consists of :* flowmeter M13, M14)* KNF diaphragm pump (6 mm OD connections only)* massblock (2 kg) + small dampeners* pump and meter mechanically connected* pump electrically connected to flowmeter

standard features* Flow: max. 6 kg/h* Pressure max. 6 bar (Inlet pressure + delta-P)* Suction pressure: 300 mbar* 6 mm OD compression type* Pumphead: PPS (Ryton)* Membrane: PTFE Coated* Valves: FFPM (kalrez)* Power Supply: +15…24 Vdc* Brushless motor

Tamb.: +5..+40 gr.CTfluid: +5…+ 80 gr.Cmax. viscosity : 150 mPa.smax. particles size: 400 µm

Dosing system consists of flowmeter + pump

Option: pulsation dampener price on request

(for use with M13, M14)

Pump unit

$US

Bronkhorst USA Inc.CONFIDENTIAL Prices $US 1 SEP 2015