  • Varian CP-4900 Micro-GCGC

  • 2Immediate answersseparations in seconds.

    Analyze anywherein the lab, in the field, or wherever you need the information.

    Always readyGC channels exchange easily for rapid maintenance.

    When the composition of gas mixtures is critical, Varians CP-4900delivers the information you need time after time. Our 4th generationmicro-GC generates more data in less time for faster and betterbusiness decisions.

    The CP-4900 is a rugged, compact analyzer for lab-quality gasanalysis at any site. With advanced micro-machining and computingtechnologies the CP-4900 offers one to four plug-and-play GCchannels. Each channel is a separate GC with pneumatics, injector,column, and detector. Low power consumption lets you take your GCto the sample source.

    Laptop PC-based software provides control, automation, and reportsto make the CP-4900 a powerful and convenient tool for operators ofall skill levels.

    The CP-4900 from Varian for simple, reliable, and cost-effective gasanalysis wherever you need it!

    The Speed You NeedThe Varian CP-4900 Micro-GC for gas analysis

  • Precise gas analysis in seconds for production and research Natural gas Refining Specialty gases Fuel cells Oil and gas exploration Anywhere precise gas analysis saves money and adds value!

    Take the CP-4900 with you Weighing from 5.2 kg and just 15 cm wide, the CP-4900 is easy to move Optional Field Case with gases and battery power for remote locations Start analyses within 15 minutes of power-up Laptop PC control of all instrument parameters and data handling

    Local or remote control of operation and data reduction Choose either Varians Star Chromatography Workstation or CP-Matre Elite

    for error-free operation Standard or custom reports with minimal operator intervention Monitor results to set limits, activate alarms, or switch valves Standard 4-20 mA signal readout for process-control Communicate with the CP-4900 from a process control computer via

    industry-standard RS232, RS485, or Ethernet protocols

    Ready to use immediately The CP-4900 arrives configured for your analysis Modular design for fast maintenance Flash memory for quick software upgrades via the internet Reconfigure for new applications in five minutes with user-installed plug and play GC channels

    3

    Fast, Reliable Answers

  • 4The faster separations provided by narrow-bore capillaryGC columns are fully exploited when all sample-associated components of the system are miniaturized.The CP-4900s micro-machined injector and detector,together with a narrow-bore column, deliver rapidseparations of permanent gases and vapors.

    Additionally, pneumatics for micro electronic gascontrol and flash memory to store current methodparameters are now integrated with the GC modulecreating plug-and-play GC channels.

    Each GC channel is a complete miniaturized GC witha narrow-bore column for high efficiency separations.

    Maintaining separation. 200 nL volume ThermalConductivity Detector (TCD)eliminates peak broadening.

    More analyses in less time for tighter processcontrol. Backflush reduces the equilibration timebetween analytical runs for many sample types.

    Increase Monitoring Frequency with Backflush Option

    With micro-electronic gas control and time-programmableBackflush, you inject sample components of interestwhile eliminating contaminants.

    Backflush prevents less volatile components and waterfrom entering the column. Baseline drift from latereluting contaminants is eliminated, and equilibrationtime between injections is substantially reduced.

    Fast analysis and frequent process monitoring with theCP-4900 ensures high quality end products.

    Microtechnology for Maximum Speed Improve data and process quality by frequent sampling

    Analytical Cycle Time Comparison

    Faster results with plug-and-play GC channels.One, two or up to four channels used in parallelfurther enhance analytical speed.

    Efficient sample introduction. Siliconmicro-machined, variable volume injectorintroduces sample in narrow band.

  • 5Reconfigure in MinutesAnd, easy maintenance when you need it

    The CP-4900 delivers the results and ruggedness youdemand in the lab and in the field for the analysis ofgas and volatile liquid streams.

    Quick and easy reconfiguration and repair withexchangeable GC channels and module sub-assemblies

    Immediate start-up with Electronic Data Sheets(EDS) which store operational history and last-usedmethods

    Trouble-free operation with new, vibration-resistant electronics

    Lower maintenance costs with detector filamentprotection

    Add and exchange GC channels to maximize uptime or to analyze a wider range of sample types.

    Reconfigure or repair. GC channels ormodules are easily user-replaceable.

  • 6A CP-4900 for Any ApplicationSatisfaction guaranteed!

    Refinery Gas

    4-Channel SystemChannel A: Al203/KCl-PLOT

    Less than 40 seconds. In this example,Channel A of a four-channel system separateshydrocarbons in a refinery gas mixture. A fullanalysis, including hydrogen, nitrogen, CO,and CO2, is complete in 200 seconds.

    Fuel Cells

    Better characterization in less time. Optimize Fuel Cell operation and design with informationgenerated by a two-channel CP-4900.

    2-Channel SystemChannel B: PoraPLOT Q

    Single-Channel SystemChannel A: MolSieve 5A PLOT

    Accuracy, speed and profitability. Precise andfrequent gas mixture measurements are essentialto successful specialty gas manufacturing.

    Complex samples such as natural gas and refinery gasare often analyzed on conventional multi-column,multi-valved gas chromatographs. With the CP-4900Micro-GC, a complete analysis is achieved withoutvalves and in a fraction of the time required with aconventional GC.

    The compact CP-4900 analyzes complex gas samplesusing the selectivity of up to four independent GCchannels. Each GC channel, with a different columnphase, simultaneously separates a different subset ofsample components.

    And, single or dual sample inlets and pumps, plusoptional gasifier for volatile liquids and pressurized gasstreams, enable the CP-4900 to handle a wide range ofsample types.

    1. iso-Butane2. n-Butane3. trans-2-Butene4. 1-Butene5. iso-Butylene6. cis-2-Butene7. n-Pentane

    1. CO22. Ethane3. Propane

    1. Oxygen2. Nitrogen3. Methane

    2-Channel SystemChannel A: MolSieve 5A PLOT

    1. Hydrogen2. Nitrogen3. Methane4. CO

    Industrial Gases

  • 4-Channel SystemChannel B: Micro-Packed HayeSep A

    1. Nitrogen2. Methane3. CO24. Ethane

    Four simultaneous separations in onereport. Data from four chromatogramsare combined in a single report.

    Complete Natural Gas Analysis in 90 Seconds

    7

    4-Channel SystemChannel D: THT

    4-Channel SystemChannel C: TBM

    1. TBM 1. THT2. Nonane

    4-Channel SystemChannel A: CP-Sil 5 CB

    1. Propane2. i-Butane3. n-Butane4. neo-Pentane5. i-Pentane6. n-Pentane7. Hexane

    Immediate and accurate calorific content. Monitor natural gas components, including ordorants,as often as you need, to assure product quality and correct value.

    Natural Gas Analysis One injection, four simultaneous separations

  • 8On the Road with CP-4900Gas analysis in the field

    Fast, accurate, and reliable data drive operation andbusiness decisions. With easy-to-use software andrugged hardware, the CP-4900 is ideal for gas analysisin the lab or in the fieldwherever you need it!

    Handle low and high level analytes in a single runwith auto-ranging detector

    Minimize condensation and maintain sampleintegrity with injector and sample lines controllableto 110 C

    Enhance sample integrity further with GC control ofstream-select valves and short sample transfer lines

    Link variables such as temperature, pressure, andflow to sample composition for more accurate andcomprehensive reports

    The CP-4900s small size and lightweight lets you moveit easily to multiple analysis sites in the field, e.g.,refineries, drilling locations, and natural gas pipelines.Portability is the solution when transporting samples tothe laboratory is impractical or when sample integritymay be compromised in transit.

    Two gas cylinders and two rechargeablebattery packs give eight hours of productivefield time. Operation is continuous withbattery packs which easily exchange whilethe GC is running. Instrument control, data analysis, and diagnostic testing can be carried out at the instrument or over the internet for a CP-4900 in the field.

    Preserve samples and protect data qualitywith immediate answers by taking the CP-4900, in its portable Field Case, right to your sample source.

    Superior Precision in a Portable Package

    Superior performance. Capable of retentiontime precision of 0.03% RSD and peak areaprecision of 0.13% RSD, the CP-4900 meetsyour need for accurate data.

    Retention Time and Area Precision

    Lab-quality gas analysis in the field. Withits rugged Field Case, the CP-4900 is easy totransport to the sample source.

  • 9Immediately run the CP-4900 and view results from alaptop or desktop PC. Simple control screens plusstandard or customized reports are easily managed bynon-specialist operators.

    For compatibility with laboratories around theglobe, Varian offers a choice of outstandingworkstation productsStar Workstation andCP-Matre Elite. Password protection on bothworkstations eliminates unauthorized dataaccess and method editing.

    As an option to a locally sited workstation, the CP-4900 can be controlled from virtuallyanywhere in the world through a PC and the internet.

    Routine Analysis and ReportingWith minimal operator intervention

    Both Star Workstation and CP-Matre Elite offer reportswhich meet regulatory agency requirements, particularlyfor the natural gas and petrochemical industries.

    Varians ISOCAL and BTU software packages takeanalytical data from the CP-4900. Specific natural gasproperties, such as calorific value, density, relativedensity, compressibility, and Wobbe Index are includedin reports which meet ISO 6976, GPA 2171, and ASTM D3588 standards.

    In addition to providing pre-packaged softwaresolutions, Varian will consult with you to developcustom software for your specific application.

    Minimal data entry to launch methods. Using pre-definedCP-Matre Elite User Shells (Quick Start Applications with StarWorkstation), sample-specific instrument control and datahandling methods are easily launched.

    Regulatory Compliance

    Varian custom software solutions. Improveproductivity and ease-of-use with additionalapplications such as valve control and datatransfer to Microsoft Excel.

  • 10

    Varian Applications and Technical SupportAll the support you expect and need

    Classroom and on-site training. Select from awide variety of courses held at Varian facilitiesor create a customized program using yourmethods and instrumentation.

    Varian is ready to meet your needs with pre-packagedsoftware solutions for the CP-4900 or consultation todevelop custom software for your specific application.

    To further support the CP-4900, Varian offers acomprehensive range of technical services including:

    Technical assistance with experienced scientists toanswer your chemistry-related questions

    Expert, factory-trained field service engineers

    Chromatography training courses for newand experienced users

    Customized training in your laboratoryusing your instruments and methods

    Varians reliable analytical instruments andsuperior customer support ensure enhancedproductivity, minimal downtime, andmaximum return on your investment.

    Varian is with you for all your support needs!

    Technical support for the lifetime of yoursystem. For responsive customer support you canrely on our Help Desks in the USA and Europe.

  • 11

    Varians 50-plus years of continuous innovation inanalytical instrumentation assures you the best in highperformance products and services. Varian is committed toproviding analytical products and supplies at affordableprices supported by superior customer service.

    Advance your analytical capabilities today. Speak with aVarian representative to discuss your specific applicationneeds, or to request your free Varian Chromatography andSpectroscopy Supplies Catalog.

    Varian 3800 GC. A versatile three-channel laboratory GC with a completerange of injectors and detectors for anyapplication.

    Varian 3900 GC. A small, easy-to-use singlechannel laboratory GC for high throughputroutine analyses.

    CP-Gas Clean Filters. Extremely efficient filtersremove moisture and oxygen to extend column lifefor both micro-GC and laboratory GC systems.

    Meeting Your Analytical NeedsVarian systems, services, and supplies

    CP-Sil Low Bleed Capillary Columns with EZ-GRIP.Low column bleed for higher precision, especiallywith GC/MS. EZ-GRIP makes column installationquick and simple.

  • WCI-0055 20M 9/01 Printed in U.S.A.

    Varian, Inc. www.varianinc.com North America 800.926.3000, 925.939.2400 Europe The Netherlands: 31.118.67.1000 Asia Pacific Australia: 613.9560.7133 Latin America Brazil: 55.11.3845.0444 Other sales offices and dealers throughout the world

    GC GC/MS HPLC AAS ICP ICP-MS UV-Vis-NIR Fluorescence NMR Analytical Supplies

    Varian, Inc. serving worldwide markets in:

    AgricultureBasic ChemicalBiotechnologyClinicalElectronicsEnvironmental PhotonicsToxicologyPharmaceuticalFood and BeverageMetals and MiningPetroleum and Petrochemical

    Varian Sales and Dealer Offices

    Varian is committed to a

    process of continuous

    improvement which

    demands that we

    understand and then meet

    or exceed the needs and

    expectations of our

    customers both inside

    and outside the company

    in everything we do.