10
Test Date 23/2 & 23/3/2016 AIS Job No. M16110 Report No. 14 Rev.1 Page No. 1 of 10 MECHANICAL TESTING REPORT PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411 Mechanical Testing Officer D. Lynch Accredited for compliance with ISO/IEC 17025. Accreditation number 13770. Corporate site number 17067. This document shall not be reproduced, except in full. Signatory D. Lynch Date of Issue 29/03/2016 Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith Proudly servicing Australian Industry Client K-Tig Purchase Order No. Location of Test 150 152 Francis Road, Wingfield 5013 Request. Not Specified Job Description Weld Trial Test Pipe (Keyhole Tig) Test Coupon No. 14 Test Specification AS 2205.5.1-2003 Weld Process Keyhole GTAW Material. Super Duplex UNS S32750, 250NB x 9.53mm W.T. Gas Mixture Argoplas + 2% Nitrogen Weld Position 1G Rotated TEST RESULTS Test No Type of Test Comments M18594 Macro Examination No Apparent Defects Etchant: 10% Oxalic Acid (Electrolytic) Figure 1, Macro Examination Sample Disposition: Samples returned to client. This test report replaces AIS test report M16110-14 issued the 24/02/2016.

MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

  • Upload
    vodien

  • View
    219

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 23/2 & 23/3/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 1 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Accredited for compliance with ISO/IEC 17025. Accreditation number 13770. Corporate site number 17067.

This document shall not be reproduced, except in full.

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Client K-Tig Purchase Order No.

Location of Test 150 – 152 Francis Road, Wingfield 5013 Request. Not Specified

Job Description Weld Trial Test Pipe

(Keyhole Tig)

Test Coupon No. 14

Test Specification AS 2205.5.1-2003 Weld Process Keyhole GTAW

Material. Super Duplex UNS S32750, 250NB x 9.53mm W.T.

Gas Mixture Argoplas + 2% Nitrogen

Weld Position 1G Rotated

TEST RESULTS

Test No Type of Test Comments

M18594 Macro Examination No Apparent Defects

Etchant: 10% Oxalic Acid (Electrolytic)

Figure 1, Macro Examination

Sample Disposition: Samples returned to client.

This test report replaces AIS test report M16110-14 issued the 24/02/2016.

Page 2: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 2 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Accredited for compliance with ISO/IEC 17025.

Accreditation number 13770. Corporate site number 17067.

This document shall not be reproduced, except in full.

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

CHARPY V NOTCH IMPACT TEST RESULTS - STRIKE FORCE -406 Joules

Test Specification: AS 2205.7.1-2203 & ASTM E23-12c Notch Depth: 2mm Impact Size: 10mm x 7.5mm

Test No Location Temp Test ˚C

Impact Strength

Joules

Lateral Expansion

(mm)

I9093 Weld -46 170. 191 2.3, 2.1

I9094 HAZ -46 230, 161 2.4, 1.9

Remarks: As requested, only 2 weld impacts and 2 impacts were tested.

Page 3: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 3 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Accredited for compliance with ISO/IEC 17025.

Accreditation number 13770. Corporate site number 17067.

This document shall not be reproduced, except in full.

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

FERRITE EXAMINATION BY VOLUME FRACTION SYSTEMATIC MANUAL POINT COUNT

TEST SPECIFICATION: The ferrite examination was carried out in accordance with ASTM E562 - 11 Standard Test Method for Determining Volume Fraction by Systematic Manual Point Count. The location of testing included the weld cap and fill, weld root and fill and adjacent heat affected zones. The average percent for each area was recorded. For the heat affected zones a majority of the evaluation was at the fusion line where the ferrite percent in considerably higher. No of Counts: 15 minimum – 30 maximum per location Grid Intersection Points: 30 Magnification: 750X – 1250X Reference No.: X1512

Location Ferrite

%

95% Confidence of Index

Relative Accuracy

%

Weld Cap and Fill 53.9 ± 1.0 1.9

HAZ Cap and Fill 56.5 ± 1.4 2.5

Weld Root and Fill 43.0 ± 0.7 1.7

HAZ Root and Fill 49.3 ± 1.2 2.4

Note:

Page 4: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 4 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Accredited for compliance with ISO/IEC 17025.

Accreditation number 13770. Corporate site number 17067.

This document shall not be reproduced, except in full.

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 2: Etched view; showing general microstructure of weld cap, ferrite (pinkish) and austenite (off

white) areas.

Figure 3: Etched view; showing general microstructure of Heat Affected Zone, between arrows

revealing ferrite (brown/orange) and austenite (off white) areas.

Page 5: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 5 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Accredited for compliance with ISO/IEC 17025.

Accreditation number 13770. Corporate site number 17067.

This document shall not be reproduced, except in full.

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 4: Etched view; showing general microstructure of weld root, ferrite (brown/orange) and

austenite (off white) areas.

Figure 5: Etched view; showing general microstructure of Heat Affected Zone, between arrows

revealing ferrite (brown/orange) and austenite (off white) areas.

Page 6: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 22/02 & 23/03/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 6 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

FERRIC CHLORIDE CORROSION TEST – TEST METHOD A - ASTM G48

TEST SPECIFICATION:

A cross section of the welded pipe, 25mm wide x 50mm in length (weld centreline) x full thickness was prepared with all cut sides polished to a P600 finish in accordance with ASTM G48 Method A “Ferric Chloride Pitting Test”. As requested both the external and internal weld caps were left as welded with minimal preparation. It was stated that no passivation or pickling was applied to the coupon after welding. The specified test duration was for 24 hours at a testing temperature of 22°C. After completion of testing the same test piece was further tested at 40°C for 24 hours, the machined sides were repolished and both the external and internal weld caps were left as per previous test conditions

Sample Size at 22°C: 50.01mm long x 24.95mm wide x 8.75mm W.T (Please note the

thickness is based on the parent material thickness and does not include the weld reinforcement).

Sample Size at 40°C: 50.01mm long x 24.86mm wide x 8.75mm W.T (Please note the thickness is based on the parent material thickness and does not include the weld reinforcement).

Test Solution: 6% FeCl³ Test Duration: 24 hours

Test No. Test Temperature

°C

Initial Weight

g

Final Weight

g

Weight Loss

g/m²

G0042 22 85.560 85.560 0

G0044 40 85.253 85.253 0

Remarks: No pitting was evident on the weld cap and weld root surfaces see figures 6-9 for the photographs of the 22°C sample before and after testing and figures 10-13 for the photographs of the 40°C sample before and after testing.

Page 7: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 23/03 & 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 7 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 6, 22°C, Showing external weld cap surface before test duration

Figure 7, 22°C, Showing internal weld root surface before test duration.

Page 8: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 23/03 & 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 8 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 8, 22°C, Showing weld cap after test duration, no pitting evident (indents are as a result of

probing the specimen).

Figure 9, 22°C, Showing weld root after test duration, no pitting evident (indents are as a result of probing the specimen).

Page 9: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 23/03 & 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 9 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 10, 40°C Showing external weld cap surface before test duration

Figure 11, 40°C Showing internal weld root surface before test duration.

Page 10: MECHANICAL TESTING REPORT - Welding Supplies, … · MECHANICAL TESTING REPORT PO Box 3063 PORT ... thickness was prepared with all cut sides polished to a P600 finish in accordance

Test Date 23/03 & 22/02/2016

AIS Job No. M16110

Report No. 14 Rev.1

Page No. 10 of 10

MECHANICAL TESTING REPORT

PO Box 3063 PORT ADELAIDE SA 5015 Phone: +61(0)8 8345 0400 Fax: +61(0)8 8345 0411

Mechanical Testing Officer D. Lynch

Signatory D. Lynch

Date of Issue 29/03/2016

Form No Issue No Issue Date Issued by 501 1.1 17/04/2013 K Smith

Proudly servicing Australian Industry

Figure 12, 40°C Showing weld cap after test duration, no pitting evident (indents are as a result of probing the specimen).

Figure 13, 40°C Showing weld root after test duration, no pitting evident (indents are as a result of probing the specimen).