2
Specifications: Supply Voltage: 9-28 VDC Max Current: 3.0 Amp Ambient Temperature: -40 to +70 o C 0 24 0 100 200 300 400 500 Voltage (V) Time (ms) Valve Response Valve Shifting Voltage Holding Voltage INPUT Vs 0 OUTPUT Vs 0 100ms or 300ms Power Holding Level PWM Output resulting % of Supply Voltage Function The Lynch Coil Saver/Fast Shift Timer provides a load with full supply voltage for a preset period of time (100msec or 300msec) then provides a voltage, reduced by PWM to a preset holding voltage level. The Coil Saver/Fast Shift Timer can be used in two ways; - To hold a solenoid with half power, therefore reducing power consumption and heat rise. - To actuate a solenoid with double voltage for a few milliseconds . Voltage Graph: Timing Graph: Features & Benefits - Improved response time. Reduces switching time. Magnetic power increase. - Saves energy by reducing holding current. - Improves machine cycles/performance. - Reduces operating temperature. - Increases the lifetime of the coil. - Output voltage is reduced to % of input voltage. - Initial time and holding voltage % are user selectable. - Flashing LED for mode indication. - Mounts directly on solenoid Type A EN 175301-803 (DIN 43650) / ISO 4400. COIL SAVER/FAST SHIFT TIMER ME7050-PP

ME7050-PP COIL SAVER/FAST SHIFT TIMER - lynch.ca

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Specifications:Supply Voltage: 9-28 VDCMax Current: 3.0 AmpAmbient Temperature: -40 to +70 oC

0

24

0 100 200 300 400 500

Vol

tage

(V)

Time (ms)

Valve ResponseValve Shifting VoltageHolding Voltage

INP

UT

Vs

0

OU

TPU

T

Vs

0100ms

or 300ms

Power Holding LevelPWM Output resulting % of Supply Voltage

FunctionThe Lynch Coil Saver/Fast Shift Timer provides a load with full supply voltage for a preset period of time (100msec or 300msec) then provides a voltage, reduced by PWM to a preset holding voltage level.

The Coil Saver/Fast Shift Timer can be used in two ways;- To hold a solenoid with half power, therefore reducing power consumption and heat rise.- To actuate a solenoid with double voltage for a few milliseconds .

Voltage Graph: Timing Graph:

Features & Benefits- Improved response time.Reduces switching time.Magnetic power increase.

- Saves energy by reducing holding current.- Improves machine cycles/performance.- Reduces operating temperature.- Increases the lifetime of the coil.- Output voltage is reduced to % of input voltage.- Initial time and holding voltage % are user selectable.- Flashing LED for mode indication.- Mounts directly on solenoid Type A EN 175301-803(DIN 43650) / ISO 4400.

COIL SAVER/FAST SHIFT TIMERME7050-PP

ME7050-PP