Upload
maximilian-fowler
View
217
Download
0
Tags:
Embed Size (px)
Citation preview
MDS ACCESS CONTROL PROGRAMMING
2nd International Tech Seminar
June 2003
Slide 2MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
• Programming software– WINCOM
• Central Unit parameters• Special Decoders parameters
– DECOWIN• Decoder addresses• Digitizer settings
• PC Registering: WINCOM• Interfacing
– PC Guard Unit: WinGU– VideoPC Interface: VPC
Relays
Sensors
FERMAX SOFTWARE
Slide 3MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– Create Database for an installation
– Open the databaseCreateOpen
STARTING TO WORK : STEP 1
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 4MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– Check database selection– Program General Information– Program users (basic)
STARTING TO WORK : STEP 2
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 5MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– START connection • FXL • Remote*• Local
– Send data to system
(*)Note: This option requires a modem connection
STARTING TO WORK : STEP 3
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 6MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
Button enabled when CONNECTED
Button enabled when NOT CONNECTED
Central unit version (when CONNECTED)
*1: Basic programming data
*2: Advance programming data
WINCOM version
Central unit number (if FXL connection)
*1
*2
Central Unit parameters
STARTING TO WORK : DETAILS & STRUCTURE
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 7MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
ACCESS DESCRIPTION
DOOR RELAY CONTROLLING DOOR RELEASE & HOW
LONG IT WILL BE TRIGGERED (seconds)
ALARM RELAY TO TRIGGER WHEN ‘S’ IS DETECTING
FOR ‘xx’ SECS
FREE ACCESS PERIOD WHEN ENABLED BY
‘UNLOCK’ USER
X
PIN CODE REQUEST WITHIN THIS PERIOD
(USING TAGS & KEYPAD)
LETS PARTICULAR SENSOR/RELAY TO BE ENABLED/TRIGGERED
A201
ACCESS PARAMETERS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 8MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING ACCESS CONTROL RESTRICTIONS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 9MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
…
…
ACCESS CONTROL PARAMETERS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 10MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
• Access Control for…
EXAMPLE
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 11MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
• Step 1: Define areas
0
1
2
3
4
5
6
7
8
9
10
11
02
3 4
5
6
1
EXAMPLE
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 12MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– Each Zone is defined by access and has an internal counter for special functions
STEP 1 : DEFINE AREAS
MAXIMUM ROOM CAPACITY
RELAY TO ACTIVATE
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 13MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING STEP 2 : DEFINE ACCESS PARAMETERS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 14MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING STEP 3 : DEFINE USER LEVELS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 15MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– 3 different time schedules (A,B,C) normally used to differentiate the kind of day
– 2 start-end periods per each day
STEP 4 : DEFINE TIME LEVELS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 16MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– 3 periods of holidays – 20 individual days
STEP 5 : DEFINE HOLIDAYS
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 17MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– Restrictions are applied to users through levels
STEP 6 : FILL IN USERS’ DATA
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 18MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
• Step 1: Set central unit to register
• Step 2: Set type of registering
• Step 3: Display incidences
1
2
3
INCIDENCES
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 19MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING INCIDENCES
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 20MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
• ACCESS DENIED:– F : Holiday– V : Holiday period– Z : Restricted Zone– A : Anti-passback– D : Restricted Day– H : Restricted by time– C : Maximum capacity reached– P : Wrong PIN code.
INCIDENCES
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 21MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– “Key Violation” : • The user that has been introduced already exists,
change the user name. It is possible to create 2 users with the same name from the outdoor panel but we will get “Key Violation”message if working with WINCOM. Delete one repeated user.
– No call is possible:• Cannot scroll the users list in the outdoor panel with
the scroll keys or call to an apartment number• Check if central unit DC switch is set to ON.(switch no.
3 )
TROUBLESHOOTING
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING
Slide 22MD
S A
CC
ES
S C
ON
TR
OL
PR
OG
RA
MM
ING
– Access denied : • If the code length is different from the code field in
users table the code will be filled with 0 at the end. It is possible to present the tag to introduce the code instead of typing it.
– A user is not allowed to enter due to restrictions but has gained access:
• Check if the user is defined in the same central unit where the access is connected.
• If it is not on the same central unit check DC switch (number 3) , must be to ON. To ask for restrictions about users from different C.U. Through FXL , DC must be switched to ON.
TROUBLESHOOTING
UNIT 2 : MDS ACCESS CONTROL PROGRAMMING