18
MCS CERTIFICATION AND DATA ACQUISITION TECHNIQUES 10KW DUAL REGULATED KAPLAN TURBINE

MCS Certification and data acquisition techniques

  • Upload
    keon

  • View
    28

  • Download
    0

Embed Size (px)

DESCRIPTION

MCS Certification and data acquisition techniques. 10kW Dual Regulated Kaplan Turbine. What’s it all About?. MCS Certification. What was the Purpose? What Will I Show You?. Introduction 1. MCS Certification 2. Obtaining the Data 3. The Results. Obtaining the Data. What was the Purpose? - PowerPoint PPT Presentation

Citation preview

Page 1: MCS Certification and data acquisition techniques

MCS CERTIFICATION AND DATA ACQUISITION TECHNIQUES

10KW DUAL REGULATED KAPLAN TURBINE

Page 2: MCS Certification and data acquisition techniques

2

• MCS Certification1

• Challenge of Obtaining Data2

• All Exciting, RESULTS! (And the Road to Getting Them)3

WHAT’S IT ALL ABOUT?

Page 3: MCS Certification and data acquisition techniques

3

MCS CERTIFICATION

• What was the Purpose?

• What Will I Show You?

Introduction1. MCS Certification2. Obtaining the Data3. The Results

Page 4: MCS Certification and data acquisition techniques

4

OBTAINING THE DATA

Introduction1. MCS Certification2. Obtaining the Data3. The Results

• What was the Purpose?

• What Will I Show You?

Page 5: MCS Certification and data acquisition techniques

5

THE RESULTS

• What was the Purpose?

• What Will I Show You?

Introduction1. MCS Certification2. Obtaining the Data3. The Results

Page 6: MCS Certification and data acquisition techniques

6

MCS CERTIFICATION

Current Situation?

Why Bother?

How Does One Obtain Certification?

Page 7: MCS Certification and data acquisition techniques

7

OBTAINING DATAWhat data did we need?

• Electrical power output• Upstream River Level• Turbine Tank Level• Downstream River Level• Water Velocity…(to be continued!)– And actuator positions……Identifies steady state

conditions

Page 8: MCS Certification and data acquisition techniques

8

POWER READINGS RIVER LEVELS

Page 9: MCS Certification and data acquisition techniques

9

OBTAINING FLOW DATA

• PITOT-STATIC TUBE

• Insertion Flow Meter Required

(Bright Hub Engineering, 2010) (Setra Solutions, 2014)

=0.235 psi = 2.9e-3 psi

£900!+/- 0.25ms-1

(Voelkner, 2014)

Other options considered, but there just isn’t time!

Page 10: MCS Certification and data acquisition techniques

10

OBTAINING FLOW DATA

WHAT WE ACTUALLY USED!

Page 11: MCS Certification and data acquisition techniques

11

OBTAINING RUN-AWAY DATA

Page 12: MCS Certification and data acquisition techniques

12

PROBLEMS

• Flow Regime

• Calibration

• Second Run

• Reliability of flow meter?

Page 13: MCS Certification and data acquisition techniques

13

CALCULATIONSɳ=

𝑃𝑀𝐸𝐶𝐻

𝑃𝑇𝐻

h𝑃𝑡 =𝑔 ·𝐻𝑛𝑒𝑡 ·𝑄𝑎

Page 14: MCS Certification and data acquisition techniques

14

CALCULATIONSSOURCES OF HEAD LOSS

Page 15: MCS Certification and data acquisition techniques

15

The Fish Screen

Inlets (Sudden Contraction)

Frictional Losses

Outlet (Sudden Expansion)

Gradual Expansions

1. At The 90ᵒ Bend

Page 16: MCS Certification and data acquisition techniques

16

Time Spent

Proj

ects

Wor

ked

On

Get Familiar

Achieve Mastery

Working Toward Mastery

Get Experience

d

Page 17: MCS Certification and data acquisition techniques

17

Doing Your Best Work

• Working from home• Working offsite• Technology

requirements

Page 18: MCS Certification and data acquisition techniques

18

QUESTIONS?