29
29/11/10 Breeam / Code for Sustainable Homes Case studies St John’s School, Marlborough

Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Embed Size (px)

DESCRIPTION

 

Citation preview

Page 1: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

29/11/10

Breeam / Code for Sustainable Homes

Case studies

St John’s School, Marlborough

Page 2: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Chase Bridge Primary, Twickenham

Canford School, Arts

Page 3: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Canford School, Science

St Polycarps, Farnham

Page 4: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Priors Court School for Autism

The Hub, Portsmouth

Page 5: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Offices, Nottingham

Royal Haslar, Gosport

Page 6: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Breeam

Breeam overview

Page 7: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Planning visualisation

Finished exterior

Page 8: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Environmental strategy

OrientationBuildings should harness the sun path and facades designed appropriately for Northern and Southern Aspects

Page 9: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

OrientationNorthern facade

OrientationNorthern façade

Page 10: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Orientation Southern façade

OrientationBrise soleil elements protect against solar gains from high summer sun

Page 11: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

VentilationM+E items such as windcatchersare often additions to elevations

VentilationM+E items such as windcatchersare often additions to elevations

Page 12: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Low carbon technologies

Low carbon technologiesPV cells / Solar boost thermal panels can be very visible

Page 13: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Thermal massExposed concrete to provide a heat sink against temp fluctuations

Cyclists facilities

Page 14: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Cyclists facilitiesThe prominent urban realm positions dictated that overbearing cyclist facilities were designed out meaning Breeam credits not achieved

Cyclists facilitiesBreeam compliant examples, these should be situated in less prominent areas as they are visual obtrusive

Page 15: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Daylighting

DaylightingProviding adequate daylighting can require rooflights, these should be part of the design aesthetic

Page 16: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

DaylightingAdequate daylighting and views are acheived.

Transport + amenitiesSome locations mean these credits cannot be achieved

Page 17: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Langley Green Children's Centre

Code for Sustainable Homes

Page 18: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Code for Sustainable Homes

Gosport Railway Station

Page 19: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Station

Gosport Railway Station

Page 20: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Station

Gosport Railway Station

Page 21: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Station

Timber frame constructionLarger amounts of insulation can be provided to bring down U values

Page 22: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Air tightnessTimber frame means air tightness is more easily achieved

Mechanical Ventilation with Heat Recovery (MVHR)Fresh air is pre warmed reducing heat loss

Page 23: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Stationdiscrete location of gas meters

Gosport Railway Station

Page 24: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Station

Page 25: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

Gosport Railway Station

Somerstown

Page 26: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

SomerstownPV cells are very likely so the design is approached to disguise these as much as possible

SomerstownFrom the road the pv cells are not visible

Page 27: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

SomerstownThe pv cells are just visible from the rear courtyard

Somerstown

Page 28: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

SomerstownCycle and bin store provision must not dominate

Air Source heat pumpsthese are very visually obtrusive and should be sited in very discrete locations

Page 29: Matt Swanton Re-Format Code for Sustainable Homes and BREEAM

PV cellsThese need to face approx due south for maximum efficiency but can visually dominate a roof