8.008.001.251.257.504.501.50 6.00 8.00 8.00 8.00 8.00 2.514.19 0.59
2.40
8.00
1.20
2.40
4.50
1.20
1.20
1.20
2.00
1.40
1.00
2.50
1.20
1.05
1.40
2.15
10.4
0
10.5
0
84.58
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
8.008.00 6.00 6.00 6.00 8.00 8.00 2.513.55 0.59 3.55
2.50
8.00
1.20
2.50
1.20
1.50
1.20
1.05
1.40
2.15
10.5
0
10.5
0
83.30
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
2.00
1.40
1.20
1.20
8.00
8.008.00 4.00
8.008.00 6.00 24.00 8.00 2.513.30 0.59 3.30
2.50
8.00
1.20
2.50
1.20
1.50
1.20
1.06
1.39
2.15
10.5
010
.50
82.80
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
2.00
1.40
1.20
1.20
8.00
16.00
4.19
10.5
0
FD
FD
FD
FD
WSCO
LAV
WC
WC
WCFD
WC
LAV
CO COCO
COCOTO THE NEAREST CATCHBASIN
ST
FD
FD
FD
WSCO
LAVUR
WC
WC
ST
FD
FD
FDUR
LAV
WS
COWC
WC
FD
FD
FDUR
LAV
WS
COWC
WC
FD
FD
FD
WS
COWC
WC
WC
LAV
FD
FD
FD
FD
WS
COWC
WC
WC
LAV
FD
FD FD FD FD FD FD FD FD FD FDFDFDFDFDFDFDFDFD
FD FD FD FD FD FD FD FD FD FDFDFDFDFDFDFDFDFD50mmØ F L O O R D R A I N S T O R M D R A I N A G E 50mmØ F L O O R D R A I N S T O R M D R A I N A G E
50mmØ F L O O R D R A I N S T O R M D R A I N A G E 50mmØ F L O O R D R A I N S T O R M D R A I N A G E
WCFD
LAV
WC
FD
FD
CO
UR
4" Ø PVC PIPE
2" Ø PVC PIPE
WC
FD
F
CO
UR
LAV
co
CO
WCFD
FD
FD
4" Ø PVC PIPE
4" Ø PVC PIPE
FLAV
LAV
F
WC
FD
WC
co
FD
FD
FD
FLAV
UR
F
FWC
WC
VTW
4" Ø PVC PIPE
CO
4" Ø PVC PIPE
GROUND FLOOR
SECOND FLOOR
THIRD FLOOR
VTW
VTW
c.o.
c.o.c.o.
c.o.c.o.
c.o.
S E PT I C V
A U L T
TO NEAREST CANAL
GRAVITY TANKCAPACITY= 2000 Litres
ROOF DECK FLOOR
C
I
S
T
E
R
N
4" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. ALAN E. MILANOREGISTERED MASTER PLUMBER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
P118 of 30
Scale: 1:250 m
GRND FLR. DRAINAGE SYSTEM LAYOUT PLAN
1
Scale: 1:250 m
2ND FLR. DRAINAGE SYSTEM LAYOUT PLAN
2
Scale: 1:250 m
3RD FLR. DRAINAGE SYSTEM LAYOUT PLAN
3
Not Drawn to Scale
RIGHT WING DRAINAGE SYSTEM ISOMETRIC DIAGRAM
4
CO
4" Ø PVC PIPE
CO
4" Ø PVC PIPE
co
FD
FD
FD
FLAV
UR
F
FWC
WC
4" Ø PVC PIPE
CO
2" Ø PVC PIPE
GROUND FLOOR
SECOND FLOOR
THIRD FLOOR
c.o.
c.o.c.o.
c.o.c.o.
c.o.
S E PT I C V A U L T
TO NEAREST CANAL
GRAVITY TANKCAPACITY= 2000 Litres
ROOF DECK FLOOR
C
I
S
T
E
R
N
FLAV
LAV
F
VTW
FD
WCFD
FD
FD
co
CO
WCFD
FD
FD
4" Ø PVC PIPE
FLAV
LAV
F
WC
FD
WC
VTR
FD
2" Ø PVC PIPE
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
UR
TO MIDDLE CR
1/2"Ø PVCWATERLINE PIPE
1/2"Ø PVCWATERLINE PIPE
1/2"Ø PVCWATERLINE PIPE
TO SETIC VAULT
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
VTR
32.00 6.00 24.00 8.00 2.513.05 0.59 3.05
2.50
8.00
2.50
10.5
010
.50
82.30
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
8.00
10.5
0
FD FD FD FD FD FD FD FD FD FDFDFDFDFDFDFDFDFD50mmØ F L O O R D R A I N S T O R M D R A I N A G
E50mmØ F L O O R D R A I N S T O R M D R A I N A G
E
8.008.001.251.257.504.501.50 6.00 8.00 8.00 8.00 8.00 2.514.19 0.59
2.40
8.00
1.20
2.40
4.50
1.20
1.20
1.20
2.00
1.40
1.00
2.50
1.50
1.20
1.05
1.40
2.15
10.4
0
10.5
0
84.58
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
8.008.00 6.00 6.00 6.00 8.00 8.00 2.513.55 0.59 3.55
2.50
8.00
1.20
2.50
1.20
1.50
1.20
1.05
1.40
2.15
10.5
0
10.5
0
83.30
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
2.00
1.40
1.20
1.20
8.00
8.008.00 4.00
4.19
R
F
F
F
FF
LAV
WC
WCWC
R
F
F
UR
F LAV
WCWC
UR
R
F
F
F
FF
LAV
WC
WCWC
R
F
F
UR
FLAV
WCWC
URCT
M
PT
CT
M
PT
WCFF LA
V WCWC
LAVF
SPRINKLERHEADS
SPRINKLERWATER SUPPLYPIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLYPIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLYPIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLY
PIPE LINE
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. ALAN E. MILANOREGISTERED MASTER PLUMBER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
P219 of 30
Not Drawn to Scale
LEFT WING DRAINAGE SYSTEM ISOMETRIC DIAGRAM
4
Scale: 1:250 m
ROOFDECK DRAINAGE SYSTEM LAYOUT PLAN
1
Scale: 1:250 m
GRND FLR. WATER SUPPLY LAYOUT PLAN
2
Scale: 1:250 m
2ND FLR. WATER SUPPLY LAYOUT PLAN
3
8.008.00 6.00 24.00 8.00 2.513.30 0.59 3.30
2.50
8.00
1.20
2.50
1.20
1.50
1.20
1.06
1.39
2.15
10.5
010
.50
82.80
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
2.00
1.40
1.20
1.20
8.00
16.00
32.00 6.00 24.00 8.00 2.513.05 0.59 3.05
2.50
8.00
2.50
10.5
010
.50
82.30
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
2.510.59
1.50
8.00
10.5
010
.50
R
F
F
F
FF
LAV
WC
WCWC
R
F
F
UR
FLAV
WCWC
UR
SPRINKLERHEADS
SPRINKLERWATER SUPPLYPIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLY
PIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLYPIPE LINE
SPRINKLERHEADS
SPRINKLERWATER SUPPLY
PIPE LINE
6.00 4.00 6.50
10.5
0
83.01
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
DC
E
B
A
A'
WCFD
LAV
CBCBCBCB
EXISTINGCATCHBASIN
100mm ØPVC DOWNSPOUT
2.45
2.00
4.004.004.004.00 4.004.004.004.006.50 4.00 4.00 4.00 4.004.00 4.00 4.00
100mm ØPVC DOWN
SPOUT
CB CB CB CB CB CB
CB
CB CB CB CBCBCBCBCBCBCB
CBCBCBCB CB CB CB CB CB CBCB CB CB CBCBCBCBCBCB
300mm Ø CON. CULVERT RUN @ 2% SLOPE300mm Ø CON. CULVERT RUN @ 2% SLOPE
300mm Ø CON. CULVERT RUN @ 2% SLOPE 300mm Ø CON. CULVERT RUN @ 2% SLOPE
300m
m Ø
CO
N. C
ULV
ERT
RU
N @
2%
SLO
PE
TO C
AMPU
SD
RAI
NAG
ESY
STEM
P R O P E R T Y L I N E P R O P E R T Y L I N E
4"Ø PVC PIPECO
WCWC
4"Ø PVCP-TRAP
4"Ø PVCP-TRAP
4"Ø PVCP-TRAP
4"Ø PVC PIPE
4"Ø PVC PIPE
4"Ø PVC PIPE
4"Ø PVC PIPE
2"Ø
PVC
PIP
E
2"Ø PVCP-TRAP
FDFD
FD
LAV
TO THE NEARESTCATCH BASIN
4"Ø PVC PIPE
4"Ø PVC PIPE
4"Ø PVC PIPE
TO SEPTIC VAULT
CO 12"Ø G.I. WATER LINE PIPE
1 2"Ø
G.I.
WAT
ER L
INE
PIPE
WC WC
LAVF
F F
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. ALAN E. MILANOREGISTERED MASTER PLUMBER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
ISOMETRIC VIEW
12"Ø
G.I. PIPE
2"Ø PVC PIPE
2"Ø
PVC
PIP
E
1 2"Ø
G.I.
PIP
E
4"Ø
PVC
PIP
E
4"Ø PVCP-TRAP
2"Ø PVCP-TRAP
VTW
4"Ø PVCP-TRAP
4"Ø PVCP-TRAP
4"Ø
PVC
PIP
E
4"Ø
PVC
PIP
E
4"Ø PVC PIPE
4"Ø PVC PIPE
TO THE NEAREST
CATH BASINTO THE
SEPTIC VAULT
WC
WC
FD
FD
FD
CO
CO
CO
LAV
F
F
F
12 "Ø G.I. PIPE
ISOMETRIC VIEW
4"Ø
PVC
PIP
E
4"Ø
PVC
PIP
E
12 "Ø G.I. PIPE
12 "Ø G.I. PIPE
FD
WC
LAV
F
2"Ø PVC
P-TRAP
1 2"Ø
G.I.
PIP
E
CO
4"Ø PVC PIPE
TO THE NEAREST
CATH BASIN
CO
CO
F
2"Ø PVC PIPE
P320 of 30
Scale: 1:250 m
3RD FLR. WATER SUPPLY LAYOUT PLAN
1
Scale: 1:250 m
ROOFDECK WATER SUPPLY LAYOUT PLAN
2
Scale: 1:250 m
GRND FLR. STORM DRAINAGE LAYOUT PLAN
3
Not Drawn to Scale
PLUMBING LAYOUT PLAN AT DIRECTOR'S OFFICE
4
Not Drawn to Scale
PLUMBING LAYOUT PLAN AT FACULTYB LOUNGE
5
SEPTIC VAULT
TO CAMPUSDRAINAGE SYSTEM
FD
FD
FD
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC
PIPE
UR
UR
LAV
CO
CO
4" Ø PVC
PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
2" Ø PVC PIPE
8.00
7.00
4" Ø PVC SOIL PIPE
4" Ø PVC
SOIL PIPE
4" Ø PVC
SOIL PIPE
3.0019 20
4" Ø WASTE STACK PIPE
SEPTIC VAULT
FD
FD
FD
FD
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE4" Ø PVC PIPE
4" Ø
PVC
SO
IL P
IPE
4" Ø
PVC
SO
IL P
IPE
LAV
CO
LAV
CO
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC PIPE
4"Ø SOIL PIPE
A7.
00
4" Ø PVC SOIL PIPE (FROM MIDDLE C.R.)TO CAMPUSDRAINAGE SYSTEM
BC
D
4"Ø WASTE PIPE
3.001 2
FHC
CISTERN
LAVF
WC
WC
UR
UR
F
F
1/2"Ø G
.I. WATER
LINE PIPE
1/2 "Ø G
.I. WATER
LINE PIPE
1/2"Ø G
.I. WATER
LINE PIPE
8.00
7.00
3.0019 20
RISER1"Ø G.I.
3/4"Ø G.I.
FHC
F
F
WC
WC
WC
LAV
LAV
1/2"
Ø G
.I. W
ATER
LIN
E PI
PE1/
2"Ø
G.I.
WAT
ER L
INE
PIPE
1/2"
Ø G
.I. W
ATER
LIN
E PI
PE
A7.
00
BC
D
3.001
RISER1"Ø G.I.
3/4"Ø G.I.
2
CISTERN
FD
FD
WC
WC
WC
FD
FD
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
LAV
LAV
4" Ø PVC
PIPE4" Ø
PVC PIPE
CO
CO
4" Ø PVC SOIL PIPE
4" Ø PVC PIPE
2" Ø PVC PIPE
4" Ø PVC
SOIL PIPE
4" Ø PVC
SOIL PIPE
7.00
4"Ø WASTE PIPE
3.0019 20
FD
FD
FD
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø
PVC
SO
IL P
IPE
4" Ø
PVC
PIP
E
4" Ø
PVC
SO
IL P
IPE
4" Ø PVC PIPE
4" Ø PVC PIPE
UR
UR
2 " Ø PVC PIPE
LAV
2 " Ø PVC PIPE
4 " Ø PVC SOIL PIPE
4 " Ø PVC PIPE
CO
CO
2 " Ø PVC PIPE
A7.
00B
CD
3.001 2
4"Ø WASTE PIPE
WC
WC
UR
LAV
FHC
UR
F
F
F
1/2"
Ø G
.I. W
ATER
LIN
E PI
PE
RISER
A7.
00
BC
D
3.001
1"Ø G.I.
3/4"Ø G.I.
21/2"Ø G.I. WATERLINE PIPE
1/2"
Ø G
.I. W
ATER
LIN
E PI
PE
(FROM MIDDLE C.R.)
WC
WC
WC
LAV
LAV
FHC
F
F
1/2"Ø G
.I. WATER
LINE PIPE
RISER
7.00
3.0019 20
1"Ø G.I.
3/4"Ø G.I.
1/2"Ø G
.I. WATER
LINE PIPE
FD
FD
FD
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC
PIPE4" Ø
PVC PIPE
4" Ø PVC SOIL PIPE
4" Ø PVC PIPE
LAV
2" Ø PVC PIPE
UR
UR
2" Ø PVC PIPE
CO
CO
4" Ø PVC
SOIL PIPE
4" Ø PVC
SOIL PIPE
7.00
4"Ø WASTE PIPE
3.001920
FD
FD
FD
FD
WC
WC
WC
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
4" Ø PVC PIPE
LAV
LAV
2" Ø PVC PIPE
4" Ø
PVC
SO
IL P
IPE
4" Ø
PVC
PIP
E4"
Ø P
VC S
OIL
PIP
E
CO
CO
4" Ø PVC SOIL PIPE
A7.
00B
CD
3.001 2
4"Ø WASTE PIPE
FHC
WC
WC
WC
LAV
LAV
F
F
1/2"
Ø G
.I. W
ATER
LIN
E PI
PE1/
2"Ø
G.I.
WAT
ERLI
NE
PIPE
RISER
A7.
00B
CD
3.001
1"Ø G.I.
3/4"Ø G.I.
2
FHC
WC
WC
UR
UR
LAV
F
F
F
F
F
1/2"Ø G
.I. WATER
LINE PIPE
1/2"Ø G
.I. WATER
LINE PIPE
RISER
7.00
2.50
3.0019 20
1"Ø G.I.
3/4"Ø G.I.
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. ALAN E. MILANOREGISTERED MASTER PLUMBER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:75 m
GRND FLR DRAINAGE SYSTEM LAYOUT PLAN
1
Scale: 1:75 m
GRND FLR WATER SUPPLY LAYOUT PLAN
4
LEFT WING RIGHT WING
LEFT WING RIGHT WING
Scale: 1:75 m
2ND FLR DRAINAGE SYSTEM LAYOUT PLAN
2
Scale: 1:75 m
2ND FLR WATER SUPPLY LAYOUT PLAN
5
LEFT WING RIGHT WING
LEFT WING RIGHT WING
Scale: 1:75 m
3RD FLR DRAINAGE SYSTEM LAYOUT PLAN
3
Scale: 1:75 m
3RD FLR WATER SUPPLY LAYOUT PLAN
6
RIGHT WING
LEFT WING RIGHT WING
LEFT WING
P421 of 30
DIGESTIVECHAMBER
TREATMENT CHAMBER
LEACHINGCHAMBER
COCO CO
INLET
OUTLET
4000 mm
1002850100850500500
100
850
100
850
2000
mm
A
A
CO
CO
100
100
B B
10mmØ @ 200mm O.C. BOTHWAYS
INLET PIPE
10mmØ @ 250mm O.C. BOTHWAYS10mmØ @ 250mm O.C. BOTHWAYS 10mmØ @ 250mm O.C. BOTHWAYS
10mmØ @ 200mm O.C. BOTHWAYS
100
200
1950
mm
10mmØ @ 600mm O.C. BOTHWAYS
350 350
10mmØ @ 600mm O.C. BOTHWAYS
INVERT ELEVATION OF INLET PIPE
100
350350350
1950
mm
200
100
INVERT ELEVATION OF CROSS-
DISTRIBUTION PIPE
1.50
Δ
0.15
0.60
10mmØ @ 0.20mO.C. B.W.0.10m
0.15m
12mmØ @ 0.30m O.C.
MANHOLE
6" THK. CHB
10mmØ @ 0.30m O.C. B.W.
10mmØ @ 0.30m O.C. B.W.
2.50
10mmØ @ 0.20m O.C.or Every Layer
100mm PVC OVERFLOW
100mm PVC OVERFLOW
1.50
Δ Δ
0.15
0.05
0.60 0.60
10mmØ @ 0.20mO.C. B.W.0.10m
0.15m
12mmØ @ 0.30m O.C.
MANHOLEMANHOLE
6" THK. CHB
10mmØ @ 0.30m O.C. B.W.
10mmØ @ 0.30m O.C. B.W.
10mmØ @ 0.20m O.C.or Every Layer
100mm PVC OVERFLOW
100mm PVC OVERFLOW
3.451.725 1.725
2.50
MMANHOLE MANHOLE
0.15m
M
SPECIFICATIONS:1. USE ELASTOMERIC WATER PROOFING2. USE SAHARA CEMENT COMPOUND FOR CEMENT MORTAR
NN
TO C D O
HIGH SCHOOL C
OMPLEX
FOOD TRADES
ADMINISTRATIO
N BLDG.
LIBRARY BLDG.
HIGH SCHOOL SCIENCE BLDG.
SCHOOL OF ENG'G. TECHNOLOGY
COLLEGE OF SCIENCE
S C S BUILDING
SOPREX
SECURITY
EMPC BLDG.
CLINIC
OLD BUILDING COMPLEX
CERAMICS
MATHEMATICS BUILDING
LAB.
CSM
AN
NEX
BASKETBALL COURT
TECHNOLOGY
AUTOMOTIVE
C B
A A
BUI
LDIN
G 1
HIGH SCHOOL LAB. BLDG.
IDS FACULT
Y BLDG.
CBAA BLDG.
ROTC & PPD
COLLEGE OF ENGINEERING
COLLEGE OF EDUCATION
GYMNASIUM
GRADUATE SCHOOL
TENNIS COURT
HOSTEL
OFFICE O
F
CHANCELLOR
IDS AUDITORIUM
ALUMNI OFFICE
OFFICESUPPLY
NATIONAL HIGHWAY
IPAD
MSU-IIT COOP AC
ADEM
Y
MOTOR POOL
NEW BUILDING COMPLEX
D H
S
DORMITORY
AUET/RAC/METBUILDING
OFFICE
PHASE 1
PHASE 1
COVERED WALKWAYCOVERED WALK
WAY
KASAMA
HOUSESTORE P.E. CLASSROOMS
MAIN ENTRANCE
CO
VER
ED W
ALKW
AY
VOLLEYBALL COURT
DITE WSHP
SCH. OF ENG'G. TECHNOLOGY
AMMEI
● THE ENTIRE INSTALLATIONS MUST BE EXECUTED UNDER THE DIRECT
SUPERVISION OF AT LEAST A LICENSED MASTER PLUMBER OR SANITARY
ENGINEER.
● ALL SOIL AND WASTE PIPES INCLUDING ITS CORRESPONDING FITTINGS AND
VENTILATION PIPES SHALL BE ALL PVC PIPES, 100mmØ FOR SOIL PIPES AND
50mmØ FOR FLOOR DRAIN, LAVATORY AND VENTILATION.
● ALL WATER DISTRIBUTION PIPES SHALL BE GALVANIZED IRON, 25mmØ
FOR MAIN LINE AND 12mmØ FOR ALL BRANCHES.
● ALL PLUMBING FIXTURES AND INSTALLATIONS SHALL BE IN ACCORDANCE
WITH THE APPROVED PLANS OF THE LOCAL OFFICE AND SHALL BE IN
CONFORMITY W/ THE PROVISION OF THE NATIONAL PLUMBING CODE OF
THE PHILIPPINES AND WITH ORDINANCES AND REGULATIONS OF THE LOCAL
PLUMBING AUTHORITY.
GENERAL SPECIFICATIONS :
WATER CLOSET
LAVATORY
URINAL
FLOOR DRAIN
FAUCET
CLEAN OUT
VENT THRU WALL
WASTE STACK
RISER
CATCH BASIN
SEWAGE LINE
WATER SUPPLY LINE
LEGEND:
WC
LAV
UR
FD
F
CO
VTW
WS
R
CB
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ENGR. ALAN E. MILANOREGISTERED MASTER PLUMBER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
Scale: 1:25 m
SEPTIC VAULT DETAIL
2
Scale: 1:25 m
CISTERN DETAIL
1
SEPTIC VAULT PLAN
SECTION THRU - B SECTION THRU - A
CISTERN PLAN
SECTION THRU - M
SECTION THRU - N
Not Drawn to Scale
LOCATION PLAN
3
this Site
P522 of 30
CERTIFIED BY:
PROPOSED INFORMATION &COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ATTY. EDGAR ALAN A. DONASCOPROFESSIONAL MECHANICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETEENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSOOIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
M123 of 30
Scale: 1:250 m
GRND FLR. FIRE ALARM SYSTEM LAYOUT PLAN
1
Scale: 1:250 m
2ND FLR. FIRE ALARM SYSTEM LAYOUT PLAN
2
Scale: 1:250 m
3RD FLR. FIRE ALARM SYSTEM LAYOUT PLAN
3
Not Drawn to Scale
FIRE ALARM SYSTEM RISER DIAGRAM
4
Not Drawn to Scale
FIRE ALARM SYSTEM ELEMENTARY DIAGRAM
5
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ATTY. EDGAR ALAN A. DONASCO
PROFESSIONAL MECHANICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
CERTIFIED BY:
PROPOSED INFORMATION &
COMMUNICATION TECHNOLOGY CENTER
(ICTC) ACADEMIC BLDG.
VICE CHANCELLOR FOR ADMIN. & FIN.
ENGR. POLAUS M. BARI, D.M.
EXECUTIVE DIRECTOR, ICTC
EMMANUEL M. LAGARE, Ph.D.ATTY. EDGAR ALAN A. DONASCO
PROFESSIONAL MECHANICAL ENGINEER
PRC No.:
PTR No.:
DATE ISSUED:
TIN No.:
PREPARED BY:
CHRISTIAN C. CAÑETE
ENGINEERING ASSISTANT, PHYSICAL PLANT DIVISION CHANCELLOR, MSU-IIT
SUKARNO D. TANGGOL, DPA
RECOMMENDING APPROVAL: APPROVED BY:
ARCHT. ANACLETO Y. TAMOSO
OIC - DIRECTOR, PHYSICAL PLANT DIVISION
SHEET No.:
DATE:
FEBRUARY 7, 2013A. BONIFACIO AVE., MSU-IIT CAMPUS, TIBANGA, ILIGAN CITY
DRAWINGS & SPECIFICATIONS & OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED, OR SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY & DOCUMENTS OF MSU - ILIGAN INSTITUTE OF TECHNOLOY , WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR
NOT. IT SHALL BE UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF & FOR OTHER PROJECTS OR BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
M224 of 30
Scale: 1:250 m
ROOFDECK FIRE ALARM SYSTEM LAYOUT PLAN
1
Scale: 1:25 m
HOISTWAY PIT PLAN
2
Scale: 1:25 m
LANDING PLAN
3
Scale: 1:25 m
OVERHEAD PLAN
4
Scale: 1:50 m
HOISTWAY SECTION
5