52
PRIVATE RESIDENCE ILLUMINATION LUSIN LIGHTING DESIGN | 2016

LUSIN DESIGN_30.07.2016

Embed Size (px)

Citation preview

PRIVATE RESIDENCE

ILLUMINATION LUSIN LIGHTING DESIGN | 2016

CONTENT

TASK

LIGHTING DESIGN

TECHNICAL

DOCUMENTATION

ARCHITECTURAL DESIGN. PLANS

INTERIOR LIGHTING

ARCHITECTURAL LIGHTING

EXTERIOR LIGHTING

RCPs

LIGHTING SPECIFICATION

LUSIN LIGHTING DESIGN 0800 860 6282

[email protected]

TASK

Hardwood

Front door

Roller Shutter GRP garage

Doors

lead dormer

cheeks

French doors

+ side lights

lead dormer

cheeks

Bi-Fold

doors

Bi-Fold

doors

lantern

roof

Slate Roof Reconstituted stone cills

quoins, heads, mullions.

Stamford Facing Stone

VeluxVelux

Velux Velux

Velux

Glas and stainless

steel guarding railsFeature

Glazed

Screen

obscure

glass

obscure

glass

Arrow

Slit

Arrow

Slit

Glas and stainless

steel guarding rails

Feature

Glazed

Screen

obscure

glass

SCALE

0 2 4 6

SCALE

0 2 4 6

Hardwood

Front door

Roller Shutter GRP garage

Doors

lead dormer

cheeks

French doors

+ side lights

lead dormer

cheeks

Bi-Fold

doors

Bi-Fold

doors

lantern

roof

Gravel Drive way

Slate Roof Reconstituted stone cills

quoins, heads, mullions.

Stamford Facing Stone

VeluxVelux

Velux Velux

Velux

Glas and stainless

steel guarding railsFeature

Glazed

Screen

obscure

glass

obscure

glass

Arrow

Slit

Arrow

Slit

Glas and stainless

steel guarding rails

Feature

Glazed

Screen

obscure

glass

Velux

SCALE

0 2 4 6

SCALE

0 2 4 6

Shower

change

Spices & prep

area

Boot

Room

w

En-Suite

En-Suite

w

En-Suite

down up

SCALE

0 2 4 6

Ground Floor Planning Approved 213sqm

First Floor Planning Approved 213sqm

Total 426sqm

Proposed Ground Floor Excluding Pool Area 262sqm.

Proposed First Floor 175sqm

Total 437sqm.

Existing buildings to be demolished ground covering 429Sqm.

SCALE

0 5 10 15

paddock area

and proposed

alotment

Shaded Areas Show Existing

Buildings To Be Removed.

SCALE

0 5 10 15

Walnut tree

Ash tree

new 1800mm high

Black Railings leading

to Post and rail

fence to be erected.

new 1800mm high

close boared timber

fence to be erected.

new stone wall to

match dwelling 750mm

high with black metal

railings

new electric gates

to be installed on stone peirs

1800mm high

gravel

drive

patio

area

patio

area

Yew

Tree

Pear

Apple

Plum

Cherry

Maple

MapleSycamore

SycamoreSycamore

Sycamore

Post and Rail

fence

Gravel access to

paddock and allotment

gates to paddock

Paddock area and Allotment area

Existing trees and

hedging to be

retained.

gate to

garden

gates to

garden

Existing Llylandii trees to be

removed and replaced with native

Blackthorn and Horn hedging, new

post and rail fence to be ereceted.

Post and rail

fence

Tarmac entrance

with acco drain

Willow Tree

existing land drain retained

Ground Floor Planning Approved 213sqm

First Floor Planning Approved 213sqm

Total 426sqm

Proposed Ground Floor Excluding Pool Area 262sqm.

Proposed First Floor 175sqm

Total 437sqm.

paddock area

and proposed

alotment

SCALE

0 5 10 15

Shaded Areas Show Existing

Planning approval 15/00259

SCALE 1250

SCALE

0 20 40 60

SCALE 1250w

En-Suite

En-Suite

w

En-Suite

downup

SCALE

0 20 40 60

LIGHTING DESIGN

LIGHTING DESIGN

INTERIOR LIGHTING

INTERIOR LIGHTING DESIGN- ENTRANCE

INTERIOR LIGHTING DESIGN- ENTRANCE

INTERIOR LIGHTING DESIGN – KITCHEN

INTERIOR LIGHTING DESIGN – DINNING ROOM

INTERIOR LIGHTING DESIGN – FAMILY ROOM

INTERIOR LIGHTING DESIGN – BILLIARD ROOM

INTERIOR LIGHTING DESIGN – TV ROOM

INTERIOR LIGHTING DESIGN INTERIOR LIGHTING DESIGN - BEDROOM 1

INTERIOR LIGHTING DESIGN INTERIOR LIGHTING DESIGN - BEDROOM 1

INTERIOR LIGHTING DESIGN INTERIOR LIGHTING DESIGN - BEDROOM 2

INTERIOR LIGHTING DESIGN INTERIOR LIGHTING DESIGN - BEDROOM 2

INTERIOR LIGHTING DESIGN - BEDROOM 2

INTERIOR LIGHTING DESIGN - BEDROOM 3

INTERIOR LIGHTING DESIGN – BEDROOM 3

INTERIOR LIGHTING DESIGN – BEDROOM 4

INTERIOR LIGHTING DESIGN INTERIOR LIGHTING DESIGN - BATHROOM

INTERIOR LIGHTING DESIGN – POOL

INTERIOR LIGHTING DESIGN – POOL

ARCHITECTURAL LIGHTING

LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

LIGHTING DESIGN LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

LIGHTING DESIGN LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

LIGHTING DESIGN LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

LIGHTING DESIGN LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

LIGHTING DESIGN LIGHTING DESIGN – ARCHITECTURAL ILLUMINATION

EXTERIOR LIGHTING

LIGHTING DESIGN LIGHTING DESIGN – EXTERIOR LIGHTING

TECHNICAL

DOCUMENTATION

SECURITY

IR

HU

B

IN

TE

RC

OM

PH

ON

E

INFRA-RED SENSOR FOR GARAGE DOORS

D

MOTION SENSOR

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

*

ENVIRONMENTAL MONITORING

GARAGE DOOR CONTROL

EXTERIOR LIGHTING CONTROL

WA

LL S

EN

SO

R P

AN

NE

L

EA

TH

ER

NE

T LA

YO

UT

Swimming pool

Shower

change

Porch

Boot

Room

TV Room

Dining

Family Room

open fire

Drawing Room

Garage

Porch

switch12

switch for pandant 2

socket for TV

mounting height determinedfrom the diagonal TV

socket

output for TV cabel

socket

switch 13

socket

switch for LED strip 1

socket

pass switch 6.2 (direction spot)

pass switch 6.1(direction spot)

socket

sw

itch for

star lights 14

double socket

waterproof

double socket

waterproof

Glazed Screen

pass sw

itch 4.2 (spot light)

pass sw

itch 3.2 (pandant lighting)

switch for LED strip 5

switch 3.1(pandant lighting)

pass switch 4.1 (spot light)

double waterproof

socket

double socket

for oven and

cooktop

(heat-resistant)

wire output for rangehood

switch for LED line

pass switch 7.2 (large pendant lighting)

pass switch 7.1(large pendant

lighting)

pass switch 8.1 (spot light)

pass switch 8.1 (spot light)

pass switch 9.2 (spot light)

pass switch 10.2 (direction spot)

pass switch 11.2 (pendan lighing)

pass switch 9.1 (spot light)

pass switch 10.1 (direction spot)

pass switch 11.1(pendan lighing)

double socket

double socket

double socket

double socket

double socket

WC

double socket

h = 900mm

h = 900mm

*height to specified

** * *

h = 900mm

h = 300mm

h = 300mm

h = 300mm

h = 1700mm

h = 900mm

h = 1000mm

h = 900mm

h =

9

00

mm

h =

3

00

mm

h =

3

00

mm

h = 900mm

h = 900mm

h = 300mmh = 900mm

h = 300mm

h = 300mm

h = 900mm

h = 900mm

h =

9

00

mm

sw

itch 19 (spot light)

socket

sw

itch 16

(spot light)

socket

sw

itch 12

(spot light)

double socket

sw

itch 21

(spot light)

sw

itch 15

(spot light)

sw

itch 10.1 (spot light)

sw

itch 11.1 (direction spot)

sw

itch 12.1 (pendant light)

switch 10.2 (spot light)

switch 11.2 (direction spot)

switch 12.2 (pendant light)

h = 900mm

h = 300mm

h =

9

00

mm

h =

9

00

mm

h =

9

00

mm

h =

9

00

mm

h =

9

00

mm

TVM intIR

intercom

phone

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

EATHERNET LAYOUT

WALL SENSOR PANNEL

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

security

REMOTE CONTROL

WALL SENSOR PANNEL

intercom

phone

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

EATHERNET LAYOUT

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

security

REMOTE CONTROL

WALL SENSOR PANNEL

D

MOTION SENSOR

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

WALL SENSOR PANNEL

REMOTE CONTROL

TVM intIR

TVM intIR

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

intercom

phone

security

intercom

phone

security

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

HVAC CONTROL

LIGHT CONTROL

ENERGY MANAGEMENT

TV/VIDEO CONTROL

*

ENVIRONMENTAL MANITORING

TERRACE LIGHT CONTROL

MUSIC CONTROL

RANGEHOOD ON/OFF CONTROL

WA

LL S

EN

SO

R P

AN

NE

L

REMOTE CONTROL

MOTION SENSOR

LIGHT CONTROL

AIR/VENT CONTROL

VENT FAN CONTROL

REMOTE CONTROL

IR

MOTION SENSOR

LIGHT CONTROL

AIR/VENT CONTROL

VENT FAN CONTROL

REMOTE CONTROL

IR

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGPOWER&DATA LAYOUT JB001 1.1 1

VC VC 26.07.2016 1:30 A0

GROUND FLOOR PLANSCALE 1:50

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

1.1 POWER & DATA LAYOUT

photosensitive detector(depends on natural lux level)

photosensitive detector(depends on natural lux level)

* - SENSORS AND DETECTORSMOUNTING PLACES SHOULDBE SPECIFIED BYRESPONSIBLE COMPANY

- DEVICES COULD BE CONTROLED WITH REMOTE CONTROLER

w

w

En - Suite 1

Bedroom 1

En - Suite 3

En - Suite 4

En - Suite 2

Bedroom 2

Bedroom 3

Bedroom 4

pass switch 22

( En -suite 2)

socket

double socket

double socket

double socket

double socket

double socket

double socket

do

ub

le

so

cke

t

do

ub

le

so

cke

t

switch 28 (spot lights)

switch 29 (pendan lighing)

double socket

double socket

sw

itch

2

1 (sm

oll sp

ots)

sw

itch

2

2d

ire

ctio

n sp

ots)

sw

itch

2

3(p

en

da

n lig

hin

g)

switch 16 (pendan lighing)

switch 17 (smoll spots)

sw

itch

2

6

double socket

En - Suite

Dressing

room

Balconey

Laundry

Room

Dressing

room

Gallery Landing

down

up

sw

itch

1

8

( E

n -su

ite

1)

sw

itch

1

9

(d

ire

ctio

n sp

ots)

double socket

h = 900mm

h = 900mm

h = 900mm

h = 900mm

h = 900mm

h = 900mm

h = 900mm

h = 900mm

h =

9

00

mm

h =

9

00

mm

h = 300mm

h =

9

00

mm

h = 900mm

h = 300mm

do

ub

le

so

cke

t

h =

3

00

mm

h = 900mm

h =

9

00

mm

h =

9

00

mm

h = 725mm

switch for mechanical

ventilation

socket waterproof

switch for

mechanical

ventilation

socket waterproof

switch for mechanical

ventilation

socket waterproof

switch for

mechanical

ventilation

socket waterproof

h = 725mm

h = 725mm

double socket

h = 900mm

switch 30 (small spots)

h = 900mm

h =

9

00

mm

sw

itch

3

1

( E

n -su

ite

1)

h = 300mm

sw

itch

2

5(p

en

da

n lig

hin

g)

sw

itch

2

4(sm

all sp

ots)

h =

90

0m

m

do

ub

le

sw

itch

2

0.1

h =

9

00

mm

do

ub

le

sw

itch

2

0.2

h =

90

0m

m

sw

itch

2

7

h =

9

00

mm

sw

itch

3

1

(sp

ot lig

hts)

h =

9

00

mm

sw

itch

3

1

(sp

ot lig

hts)

h = 900mm

switch 31

(spot lights)switch for

mechanical

ventilation

socket

waterproof

h = 725mm

double socket

h = 300mm

double socket

h = 300mm

double socket

h = 750mm

sw

itch

4

4

h =

9

00

mm

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

ENVIRONMENTAL MONITORING

*

WA

LL

S

EN

SO

R P

AN

NE

L

EA

TH

ER

NE

T L

AY

OU

T

REMOTE CONTROL

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

ENVIRONMENTAL MONITORING

*

WA

LL

S

EN

SO

R P

AN

NE

L

EA

TH

ER

NE

T L

AY

OU

T

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

ENVIRONMENTAL MONITORING

*

WA

LL

S

EN

SO

R P

AN

NE

L

EA

TH

ER

NE

T L

AY

OU

T

intercom

phone

REMOTE CONTROL

intercom

phone

REMOTE CONTROL

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

ENVIRONMENTAL MONITORING

*

WALL SENSOR PANNEL

EATHERNET LAYOUT

intercom

phone

REMOTE CONTROL

MOTION SENSOR

LIGHT CONTROL

AIR/VENT CONTROL

VENT FAN CONTROL

IR

REMOTE CONTROL

MOTION SENSOR

TERMOSTAT

SECURITY AND ALARM

LIGHT CONTROL

ENERGY MANAGEMENT

ENVIRONMENTAL MONITORING

*

REMOTE CONTROL

MOTION SENSOR

LIGHT CONTROL

AIR/VENT CONTROL

VENT FAN CONTROL

REMOTE CONTROL

IR

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGPOWER AND DATA LAYOUT JB001 1.2 1

VC VC 26.07.2016 1:30 A0

1.2 POWER AND DATA LAYOUT

FIRST FLOOR PLANSCALE 1:30

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

* - SENSORS AND DETECTORSMOUNTING PLACES SHOULDBE SPECIFIED BYRESPONSIBLE COMPANY

- DEVICES COULD BE CONTROLED WITH REMOTE CONTROLER

Swimming pool

Shower

change

Porch

Boot

Room

TV Room

Kitchen

Dining

Family Room

open fire

Drawing Room

Spices & prep

area

Garage

Porch

switch12

sw

itch for pandant 2

socket for TV

mounting height determinedfrom the diagonal TV

socket

output for TV cabel

socket

switch 13

socket

sw

itch for LE

D strip 1

socket

pass switch 6.2

pass switch 6.1

socket

sw

itch for

star lights 14

double socket

waterproof

double socket

waterproof

Glazed Screen

pass sw

itch 4.2

pass sw

itch for pandant 3.2

switch for LED strip 5

switch for pandant 3.1

pass switch 4.1

double waterproof

socket

double socket

for oven and

cooktop

(heat-resistant)

wire output for rangehood

LE

D line

switch for LED line

pass switch 7.2

pass switch 7.1

pass switch 8.1

pass switch 8.1

pass switch 9.2

pass switch 10.2

pass switch 11.2

pass switch 9.1

pass switch 10.1

pass switch 11.1

double socket

double socket

double socket

double socket

double socket

WC

S

double socket

LED STRIP ALONG

THE PERIMETRE

LED STRIP ALONG

THE PERIMETRE

ST1 ST1ST1 ST1

ST2

ST2 ST2

ST2 ST2 ST2

ST2

ST2

ST2

ST2

G1 G1 G1

ST3

ST3

ST3

ST3

ST3 ST3 ST3 ST3

ST3

ST3 ST3

ST3

ST3

ST3 ST3

ST3

ST3

ST3

ST3

ST3 ST3 ST3 ST3 ST3 ST3 ST3 ST3

ST3

ST3

ST3

ST3

ST3

ST4

ST4

ST4

ST4

OUTPUT FOR FASADE ILLUMINATIONST5

ST5 ST5 ST5 ST5

ST5

ST5 ST5 ST5

ST5 ST5

ST5ST5

ST5

ST5

ST5

ST5ST5

ST5ST5

S1

S1

S1

S1

S1

S1 S1

S1

switch 12

switch 10.2 (spot light)

switch 11.2 (direction spot)

switch 12.2 (pendant light)

sw

itch for exterior light S

T1+

fasades

double socket

waterproof

sw

itch for exterior light S

T2

sw

itch for exterior light S

T3 +

S

T4

switch 21

(strip light)

switch 16

S1

S1S1

S1

S1 S1

S1S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

D

D

D

D

D

D

D

D

DD D

DD

D

D

DD D

DD D

D

D

D

D

D

D

D

D

D

D

D

D

D D

D

D

D

D

S1

S1

S1

S1

S1

S1

S1

S1

S1 S1

S1S1

P1

P1

P1

P1 P1 P1

S1 S1 S1

S1 S1 S1

S1 S1 S1

S1 S1

switch 10.1 (spot light)

switch 11.1 (direction spot)

switch 12.1 (pendant light)

P2

S1 S1 S1

S1 S1 S1

S1 S1 S1

S1 S1 S1

S1 S1

S1 S1S1

S1

S1

S1 S1 S1

S1

D

double socket

double socket

double socket

S1 S1S1

S1

switch 15

S1 S1

S1S1

S1 S1

S1S1

P1

P2

W

W

W

W

W

W

sw

itch for star lights 14.1

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGLIGHTING CIRCUITS JB001 1.3 1

VC VC 26.07.2016 1:50 A0

GROUND FLOOR PLANSCALE 1:50

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

1.3 ELECTRICAL LAYOUT. LIGHTING CIRCUITS

En - Suite 1

Bedroom 1

En - Suite 3

En - Suite 4

En - Suite 2

Bedroom 2

Bedroom 3

Bedroom 4

p

a

s

s

s

w

i

t

c

h

2

2

socket

double socket

double socket

double socket

double socket

double socket

double socket

do

ub

le

so

cke

t

do

ub

le

so

cke

t

switch 26

switch 27

T4

T4

T3

T3

T2

T2T1

T1 double socket

double socket

sw

itch

2

0

sw

itch

2

1

sw

itch

2

1

switch 16

switch 17

T3 T3

sw

itch

2

5

socket

En - Suite

Dressing

room

Balconey

Laundry

Room

Dressing

room

Gallery Landing

down

up

sw

itch

1

8

sw

itch

1

9

double socket

do

ub

le

so

cke

t

switch for mechanical

ventilation

socket waterproof

switch for mechanical

ventilation

socket waterproof

switch for mechanical

ventilation

socket waterproof

switch for mechanical

ventilation

socket waterproof

double socket

switch 28

sw

itch

2

9

switch 24(pendan lighing)

switch 23(small spots)

w

w

double switch 20.1

double switch 20.2

sw

itch

2

7

switch 31(spot lights)

switch 31 (spot lights)

switch 31

(spot lights)

switch for

mechanical

ventilation

socket

waterproof

double socket

double socket

double socket

S2 S2

S2 S2S2

S2S2 S2

S2

S2

S2 S2

D1 D1 D1

D1

D1

D1

P1P1

P1

P1

S2S2

S2

S2

S2

S2

S2

S2

S2

S2

S2 S2

S2S2

S1 S1 S1

S1 S1

S1S1

S1

S1

S1

S1 S1

S1

S1

S1 S1

S1

S1

S1S1S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1 S1 S1

S1

S1S1

S1S1

S1S1S1

S1S1S1

S2 S2 S2S2

S2

S2S2S2S2S2S2S2S2S2S2

S2S2

S2 S2 S2 S2S2 S2 S2

S2 S2 S2 S2

S2

S2

S2

S2

S2S2S2S2

S2

S2S2 S2

S2 S2 S2

S2 S2 S2 S2

S2 S2

S2

S2

S2S2S2S2

S2

S2 S2

sw

itch

4

4

LED line - floor recessed items

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGLIGHTING CIRCUITS JB001 1.4 1

VC VC 26.07.2016 1:30 A0

FIRST FLOOR PLANSCALE 1:30

1.4 ELECTRICAL LAYOUT. LIGHTING CIRCUITS

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

Swimming pool

Shower

change

Porch

Boot

Room

TV Room

Kitchen

Dining

Family Room

open fire

Drawing Room

Spices & prep

area

Garage

Porch

switch18

(spot light)

sw

itch 14 for pandant 2

socket for TV

mounting height determinedfrom the diagonal TV

socket

output for TV cabel

socket

switch 17

(spot light)

sw

itch 13 for LE

D strip 1

Glazed Screen

switch 4.2

switch for pandant 3.2

switch for LED strip 5

switch for LED line

double socket

WC

pass switcher 20 for star lights

S1 output

S1 output

S1 output

S1 output

S1 output

S1 output

S1 output

S1 output

lighting line 1

lighting line 3

lighting line 3

lighting line3

lighting line 3

P2 output

sw

itch 22 for exterior light S

T1+

fasades

double socket

waterproof

sw

itch 23 for exterior light S

T2

sw

itch 24 for exterior light S

T3 +

S

T4

output in the wall for LED line -

2.1-2.15m from floor level

G1 output G1 output G1 output

T1 output T1 output T1 output T1 output

ST2 output

ST2 output

ST2 output

ST2 output

ST2 output

ST2 output ST2 output

ST2 output

ST2 output

ST2 output

ST4 outputST4 output

ST4 outputST4 output

ST4 output

ST4 output

ST4 outputST4 output

ST4 output

ST4 output

ST4 output

ST4 outputST4 output

ST4 output

ST4 output

ST4 outputST4 output

ST4 outputST4 output

ST3 output

ST3 output

ST3 output

ST3 output

ST3 output ST3 output ST3 output

ST3 output

ST3 output

ST3 output

ST3 output

ST3 output

ST3 outputST3 outputST3 outputST3 outputST3 outputST3 outputST3 outputST3 output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

ST3

output

lighting line 4

lighting line 4

lighting line 4

switch 19 for spot light

lighting line 2

lighting line 2

S1 output

S1 output

S1 outputS1 output

S1 output

S1 outputS1 output

S1 output

S1

output

S1

output

S1

output

S1

output

P2 output

lighting line7

lighting line 5

lighting line 6

S1

output

S1

output

S1

output

S1

output

lighting line 8

lighting line10

pass switch 9.2 (spot light)

pass switch 10.2 (direction spot)

pass switch 11.2 (pendant lighing)

pass switch 9.1 (spot light)

pass switch 10.1 (direction spot)

pass switch 11.1

(pendant lighing)

double socket

S1 output

S1 output

S1 output

S1 output

S1 output

S1 output

S1 output

S1

output

S1

output

S1

output

S1

output

S1

output

P2

output

P2

output

P2

output

D output

D output

D output

D output

D output

D output

D

output

D output

D output

D output

D output

D output

D

output

D

output

D

output

D

output

D

output

D outputD output

D

output

D

output

D outputD outputD output

D

output

D

output

D output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1 outputS1 outputS1 output

S1 outputS1 outputS1 output

S1 output

S1

output

S1

output

S1

output

S1

output

S1 output

S1 outputS1 output

S1 output

S1 output S1 output

S1 output

S1 output S1 output S1 output

S1 output

S1 output

S1 outputS1 outputS1 outputS1 output

S1 output

S1 output

P1 output

P2 output

P2 output P2 output

S1 output

S1 output

S1 output

S1 outputS1 output

S1 output S1 outputS1 output

S1 outputS1 output

S1 output

D output

D output

D output

D output

D output

D output

D output

D output

D output

D

output

D

output

D

output

pass switch 6.2 (direction spot)

pass switch 6.1(direction spot)

pass switch 7.2 (large pendant lighting)

pass switch 7.1(large pendant )

pass switch 8.1 (spot light)

pass switch 8.1 (spot light)

output in the w

all for LE

D line -

1.45-1.5m

from

floor level

output in the wall for LED line -

2.45-2.5m from floor level

switch 4.1/

switch for pandant 3.1

to the first floor

lighting line5,6,7

switch 15 (spot light)

switch 12 (spot light)

switch 10.1 (spot light)

switch 11.1 (direction spot)

switch 12.1 (pendant light)

switch 10.2 (spot light)

switch 11.2 (direction spot)

switch 12.2 (pendant light)

switch 16 (spot light)

switch 21

(strip light)

ST5 output

ST5 output

ST5 output

ST5 output

lighting line 9

lighting line 9

lighting line6

lighting line12

lighting line 13

lighting line 14

lighting line 12

lighting line 15

lighting line 15

lighting line 15

lighting line 15

lighting line 16

lighting line 15

lighting line 17

lighting line 16

lighting line 18

lighting line 19

lighting line 17,18, 19

lighting line 16, 17

lighting line 12

lighting line 13, 14, 15

lighting lines 8

lighting line37

lighting line37

lighting line38

lighting line38

lighting line 39, 40

lighting line 40

lighting line 40

lighting line 39

lighting line38

lighting line39

pass switcher 20.1 for wall lights

W output

W output

W output

W output

W output

W output

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGLIGHTING LAYOUT JB001 1.5 1

VC VC 26.07.2016 1:50 A0

GROUND FLOOR PLANSCALE 1:50

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

1.5 LIGHTING LAYOUT

En - Suite 1

Bedroom 1

En - Suite 3

En - Suite 4

En - Suite 2

Bedroom 2

Bedroom 3

Bedroom 4

En - Suite

Dressing

room

Balconey

Laundry

Room

Dressing

room

Gallery Landing

down

up

sw

itch

2

7

( E

n -su

ite

1

)

S2

output

S2

output

S2

output

S2

output

P1

output

D output

D output

D output

S1

output

S1

output

S1

output

S2

output

S2

output

S2 output

S2 output S2 output

S2

output

S2

output

switch 25 (pendan lighing)

switch 26 (small spots)

D

output

D

output

D

output

S1

output

S1

output

S1

output

S1

output

switch 22

( En -suite 2)

sw

itch

3

0 (sm

all sp

ots)

sw

itch

3

1(d

ire

ctio

n sp

ots)

sw

itch

3

2(p

en

da

n lig

hin

g)

S2

output

S2

output

S2

output

S2

output

S2

output

S2

output

S2

output

S2 output

P1

output

P1

output

S2

output

sw

itch

3

4(p

en

da

n lig

hin

g)

sw

itch

3

3(sm

all sp

ots)

S1

output

S1

output

S1

output

S2

output

S2

output

S2

output

2xS2

output

P1

output

sw

itch

1

9

(d

ire

ctio

n sp

ots)

switch 35(En -suite 3)

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

switch 40( En -suite 4)

S1

output

S1

output

S1

output

switch 37 (spot light)

switch 38 (pendan lighing)

switch 39 (small spots)

S2 output

S2 output

2хS2 output

S2

output

12x S2

output

S2 output S2 output S2 output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1 output

S1

output

S1

output

S1

output

S1

output

S1

output

S1

output

S1output S1output

S1output

4xS2 output

S2

output

S2

output

S2

output

for graund floor

S2

output

S2

output

9хS2

output

4хS2

output

double switch 29.1

(small spots/ spot lighting)

double switch 29.2

(smoll spots/

spot lighting)

sw

itch

3

6

(sp

ot lig

ht)

switch 41

(spot light)

switch 42

(spot light)

switch 43

(spot light)

lig

htin

g lin

e 1

5

lig

htin

g lin

e 1

6

lighting line 17

lighting line 28

S1 output

lighting line 19

lighting line 19

lighting line 20

lighting line 20

lighting line 21

lighting line 23

lighting line 21

lighting line 22

lighting line 18

lighting line 16

lighting line 15

lighting line 22

lighting line 23

lighting line 17

lighting line 19

lighting line 24

lighting line 25

lighting line 26

lighting line 27

lighting line 28.1

lighting line28.2

lighting line 29

lig

htin

g lin

e 3

2.1

lig

htin

g lin

e 3

0

lighting line 31

lighting line 32.2

lighting line 29,30,31,33

lighting line 28.1, 28.2

lighting line 32.1, 32.2

lighting lines 24,25,26,27

S2

output

S2

output

S2

output

S2 output S2 outputS2 output

S2 output

S2 outputS2 output

S2 output

S2 output

S2 output S2 output

S2

output

S2

output

S2

output

switch 44 for LED line

lighting line 33

LED line

output

photosensitive detector(depends on natural lux level)

D

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

Rev. Description Drn. Check.Date

This calculation is based upon specified

parameters supplied by the client, and other

assumed design inputs, as detailed in this

document. In practice, there may be variations

due to differences in as-installed luminaire

positioning, room surface reflectance, supply

voltage, photometric tolerances, etc, & normally

accepted uncertainties. We reserve the right to

modify the scheme if relevant information

subsequently becomes available.

PRIVATE HOUSE RECONSTRUCTION PROJECT

ELECTRICAL AND LIGHTINGLIGHTING LAYOUT JB001 1.6 1

VC VC 26.07.2016 1:30 A0

FIRST FLOOR PLANSCALE 1:30

1.6 LIGHTING LAYOUT

TO CONFIRM ON SITE WITHOWNER FOR FINAL SIGN OFF

Rev. Description Drn. CheckedDate

PROJECT

CLIENT

TITLE

DATEDESIGNED

REV

SIZESCALE

PROJECT No

CHECKED

DRG No

PRIVATE HOUSE RECONSTRUCTION PROJECT

LIGHTING SPECIFICATION JB001 1.7 1

VC VC 26.07.2016 -//- A3

1.7 LIGHTING SPECIFICATIONSYMBOL TYPE DESCRIPTION QTY.

S1 SPOT LIGHT 136

S2 SMALL SPOT 85

D1 DIRECTIONAL SPOT LIGHT 6

D DIRECTION SPOT 40

S STAR LIGHTS 1

LED LED STRIP

P1 LARGE PENDANT 7

P2 PENDANT 2

T1 TABLE LAMP 2

T2 TABLE LAMP 2

T3 TABLE LAMP 4

T4 TABLE LAMP 2

ST1 LIGHT UP 4

ST2 DRIVEWAY LIGHTS 10

ST3 FLOOD LIGHTS 32

ST4 FLOOD LIGHTS 4

ST5 WALL LIGHTS 19

G1 GARAGE LINEAR LUMINAIRES 3

W POOL WALL LIGHTS 6

LIGHT SENSOR 8

TV

M

int

IR

D

intercom

phone

security

INFRA-RED SENSOR

MUSIC SYSTEM

TV/VIDEO SYSTEM

INTERNET DEVICES

PHOTOSENSITIVE DETECTOR(DEPENDS ON NATURAL LUX LEVEL)

INTERCOM STATION & PHONEOUTPUT

SECURITY SYSTEM MONITOR

LUSIN LIGHTING DESIGN | 2016 www.lusinlightingdesign.com