Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
An outstanding technological profile and Beghelli brand value are
the hallmarks of a project to renew light sources for emergency
lighting. The Stella Polare project uses high efficiency LEDs and
a calibrated light beam for adequate illumination and excellent
energy saving.
The concept behind the Luce Utile project is based on the need
to have a light beam that is ideal for emergency lighting while
achieving the best illumination performance possible. The optics
have been designed specifically to solve ground lighting pro-
blems with the lowest number of luminaires, while conforming to
the values of current standards.
We are proud to unveil our new concept of emergency lighting,
which goes beyond the boundaries of mere product innovation
and instead heralds a breakthrough in the sector.
We are sure that all industry operators, from designers to archi-
tects, wholesalers and fitters, will appreciate the innovative con-
cept behind “Stella Polare” and will relay the benefits to their own
clients, with the ultimate aim of achieving safety in the places whe-
re we live, work and play.
Gian Pietro Beghelli
With “Stella Polare”, Beghelli has made a breakthrough in the
emergency lighting sector, in terms of managing light flows and the
“intelligence” of safety lighting systems. Industry operators now
have a range that is ideal for combining technology and safety pro-
cedures, in line with the recommendations of the UNI CEI mixed
working group, which I coordinated, and which produced the stan-
dard UNI CEI 11222.
Fabio Pedrazzi
LuceUtile ProjectIt doesn't matter how much light a luminaire emits.
It is what its light shows that is important,and transforms it into a useful light source.
All light apart from the controlled beam is a waste of energy.
T H E L E A D I N G E M E R G E N C Y L I G H T I N G F I X T U R E S
1
Leading lights in the world of emergency lighting . . . . . . . . . . . . . .2
Fixtures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Acciaio LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Logica LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Recessed Lungalargaluce LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Ceiling-mounted Lungalargaluce LED . . . . . . . . . . . . . . . . . . . . . . . .24
Formula 65 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Design Tech LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Fruttoluce 1 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Fruttoluce 2 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Fruttoluce 3 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Fruttoluce 6 LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Granluce LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Creativa LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
LED emergency module - Inverter . . . . . . . . . . . . . . . . . . . . . . . . . .84
Indica LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 - 100
Illumina LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Technical attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .114
Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
AT - Autotest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
LG - Logica . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
LGFM - Logica FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118
Installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Total quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
Quick, accurate installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Photometric diagrams and Luce Utile . . . . . . . . . . . . . . . . . . . . . .128
Analytical index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
fixtures, accessories and spare parts
Symbols and type approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .140
Table of contents
2
Leading lights in the
4 years' warrantyThe quality of our products means we give
customers 4 years' warranty on all parts,
including the battery
Conformity to standardsThe Stella Polare LED, the new LED
emergency lighting range, has been designed
in conformity with the latest European
standards
Quick to installSimple, effective solutions
minimise installation times
3
world of emergency
lighting
Design and rangeWe have conceived a design which takes into
account style and architectural needs, to
produce the world's most extensive range of
LED emergency lighting
The environment and
energy savingAll fixtures are manufactured using top-quality
materials which may be entirely recycled.
The LED system also guarantees considerable
energy saving
IntelligenceWe have designed the most important range
of control systems, to guarantee operation
over time.
The AT, LG and LGFM systems meet the
requirements of UNI 11222
4
Safety lighting for every kind of environment
ARCHITECTURAL SECTORS
Luxury hotels, design boutiques, historical
buildings, museums, show rooms, office districts
CIVIL SECTOR
residential buildings, small businesses
COMMERCIAL AND INDUSTRIAL SECTORS
Schools, public authorities, hotels and other
kinds of accommodation, offices, industrial
IP66
5
Contents
of fixtures
Emergency lighting
CREATIVA LED
page 80
LUNGLARGALUCE LED
page 20
LUNGLARGALUCE LED
page 26
ceiling-mountedrecessed
IP40
FRUTTOLUCE 1 LED
page 46
IP40
FRUTTOLUCE 2 LED
page 52
IP40
FRUTTOLUCE 3 LED
page 58
IP40
FRUTTOLUCE 6 LED
page 64
IP40IP55
IP43 IP42
DESIGN TECH LED
page 40
IP40
FORMULA 65 LED
page 34
IP65
GRANLUCE LED
page 70
IP65
LED module with inverter
LED MODULE WITH INVERTER
page 86
IP40
Signs
INDICA LED 30
page 102
IP42
ACCIAIO LED
page 8
LOGICA LED
page 14
IP65
INDICA LED 20
page 94
IP42
Portable emergency lighting
ILLUMINA LED
page 110
IP40
6
An outstanding performance for
LED emergency lighting in the
commercial and industrial sectors.
The structural simplicity of the
Acciaio LED, combined with
technical materials such as die-
cast aluminium and tempered
glass, has been specifically
designed for an outstanding
performance in particularly
complex conditions, thanks to an IP
rating of IP66 E IK09.
This simple yet sturdy luminaire is
shown to its sleek, stylish best with
a top-of-the-range reflector.
7
Metal and glass,
sturdy and 100% recyclable
Acciaio LEDrecessed or wall-mounted
CONFORMS TO THE ATEX DIRECTIVE
94/9/EC FOR ZONES 2 AND 22
with accessories
to be ordered separately
AC
CIA
IO
LED
8
Acciaio LED features a high technological content for particularly com-plex applications in high risk areas. The die-cast aluminium housing andglass screen have an excellent mechanical strength (IK09) and resistwell to aggressive chemical agents. In industrial applications, the fixtureis ideal for installation in areas with explosive atmospheres caused bygaseous alterations or airborne combustible dust (as indicated in theATEX Directive 94/9/EC). The reflector is in 99.99% antiridescent poli-shed aluminium, with a dual reflection optical system for more uniformillumination. The dual series of high-performance LEDs has a specialextra lens, to make screen illumination even more uniform. The AcciaioBeghelli also features a revolutionary lamp test system ( ): a magneticswitch allows for manual testing of the operation of one fixture, bymoving a magnet close to it, to immediately test efficiency.The safety sign version of the Acciaio LED has an additional opalinepolycarbonate screen for easier installation, which also guaranteesextremely uniform sign illumination (over 500cd/m2). The range alsoincludes a number of measures for easier installation, such as: an incor-porated bubble level, a quick-fit system, feed through wiring, dual wireentry for each terminal, stainless steel, wide-head screws.The following special items are also available on request: self-extingui-shing, polycarbonate screen, laminated glass screen and vandal proofscrew.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
TE
ST
Acciaio LEDEmergency LED
IK09IP66TE
ST
F
230V50Hz12 HOURS
CHARGING
IPPLUG
B
L HH1
* Minimum flow guaranteed according to EN 60598-2-22
15004 ACC LED 8W SE/SA/PS LG 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 24 160/160/90 112 1/3,5 2,5 6
15006 ACC LED 24W SE/SA/PS LG 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 24 224/224/125 157 1/6,5 2,5 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
8
24
15000 ACC LED 8W SE AT 1N SE 1h NiCd 7.2V 0.75Ah 24 160 - 1 2,5 6
15001 ACC LED 8W SA AT 1N SA 1h NiCd 7.2V 0.75Ah 24 160 96 3,5 2,5 6
15002 ACC LED 24W SE AT 1N SE 1h NiCd 7.2V 0.75Ah 24 224 - 1 2,5 6
15003 ACC LED 24W SA AT 1N SA 1h NiCd 7.2V 0.75Ah 24 224 135 6,5 2,5 6
15008 ACC LED 24W SE/SA AT 1/3N SE/SA 1/3h xxxx 24 xxx - 1 2,5 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
8
8
24
24
24
8 392 175 60 13 30 m 30 m
24 392 175 60 13 30 m 30 m
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • Visibility distance (VD)W L B H H1 screen double-sided
GENERAL SPECIFICATIONS
Power 8, 24 W
Operation SE, SA, HT, Maintained (SA)/Non-main-
tained (SE)/Public Venues (PS) may be
selected with the DIP switch for the LG,
LGFM versions
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222 DIN 4844-1, ISO 7010
ATEX�94/9/EC�for�zones�2-22
(installing the ATEX kit)
IP�rating� IP66
Duration� 1h or 1h/2h/3h, may be selected with
the DIP switch for the LG, LGFM versions
Mounting� wall, ceiling, recessed, false ceiling,
double-sided
Housing� RAL 7035 die-cast aluminium
Stainless steel screws
Optic symmetrical, polished aluminium
AT LG HT
15009 ACCIAIO EM RIGHT/LEFT/DOWN SCREEN
15010 ACCIAIO EM DOUBLE-SIDED RIGHT/LEFT/DOWN SCREEN
15011 ACCIAIO EM DOUBLE-SIDED DOWN SCREEN
15012 ACCIAIO EM FALSE CEILING/RECESSED BRACKET
15016 ACCIAIO EM WALL BRACKET FOR DOUBLE-SIDED MOUNTING
15017 ATEX�KIT
Accessories to be ordered separately
Ordering Code Article
15009 ACCIAIO EM RIGHT/LEFT/DOWN SCREEN (excluding the AT system SE version)
- 2 INVISIBLE CONNECTORS WITH IP PLUG MEMBRANE
Accessories supplied
Ordering Code Article
UV-OIL
960°C
03
03
03
03
03
HHOSPITAL
HH
9
15016 wall bracket for double-sided screen to be ordered separately
15010 housing+double-sided RIGHT/LEFT screen to be ordered separately
15011 housing+ double-sided DOWN screen to be ordered separately
WALL DOUBLE-SIDED MOUNTING
15012 recessed bracket to be ordered separately
CEILING, RECESSED MOUNTING
15012 recessed bracket to be ordered separately
SEMI- RECESSED MASONRY WALL MOUNTING
- N. 2 invisible connectors supplied
INVISIBLE CONNECTOR
15010 housing+double-sided RIGHT/LEFT screen to be ordered separately
15011 housing+ double-sided DOWN screen to be ordered separately
15012 false ceiling/recessed bracket to be ordered separately
CEILING/FALSE CEILING RECESSED DOUBLE-SIDED MOUNTING
* Minimum flow guaranteed according to EN 60598-2-22
15005 ACC LED 8W SE/SA/PS LGFM 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 24 160/160/90 112 2/4,5 2,5 6
15007 ACC LED 24W SE/SA/PS LGFM 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 24 224/224/125 157 2/7,5 2,5 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
8
24
17450 ACC LED 8W HT IP66 - - - 24 - 160 2,5 2,5 1
17451 ACC LED 24W HT IP66 - - - 24 - 224 5,5 2,5 1
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Alimentazione da tensione di rete (ca 230V 50 Hz - cc 216V)
8
24
Terminal block for a 1 - 2.5 mm wire, with 2 inputs per terminal
WALL/CEILING MOUNTING - QUICK TERMINAL BLOCK AND BUBBLE LEVEL
- REED bulb and magnetic key provided supplied
MAGNETIC SWITCH FOR LOCAL MANUAL DIAGNOSIS
- 2 IP PLUG wiring membranes provided supplied
IP PLUG WIRING MEMBRANE
Hole dimensions: 378 x 163 mm
HH
AC
CIA
IO
LED
CEILING MOUNTINGThe ideal anti-panic photometricsthe ideal photometrics for the Acciaio LED emergency
luminaire, with symmetrical optic comprising two series of
ultra efficient miniature LEDs (over 100 lumens/Watt) to
make it effective at over 3 metres high, and suitable for
ceiling mounting.
The dual reflection, optical configuration produces a parti-
cularly wide-ranging photometric solid, enabling long
distances between installation centres.
WALL MOUNTING diffused emergency lighting, an outstanding sign that hasexcellent illumination, contrast and uniformity.The symmetrical configuration of the light beam guaran-
tees excellent results also for wall mounting.
The amplitude of the photometric solid makes the Acciaio
LED Beghelli an optimal solution for lighting industrial
areas, in compliance with ATEX directive requirements for
zones 2 and 22. The outstandingly uniform illuminance,
combined with a silk-screen printed polycarbonate
screen, make the Acciaio LED a top-of-the range product
for safety sign fixtures in high-risk industrial environments.
RECESSED MOUNTINGless overall dimensions required and less exposure to external agentsThe recessed mounting system for the Acciaio LED
makes it even more compact, with no need for a reces-
sed box as the aluminium housing is used integrated with
a special mounting bracket. This configuration minimises
the overall dimensions of emergency luminaires and sign
units, reducing exposure to shocks and external agents.
10
11
AC
CIA
IO
LED
1212
1313
A perfect technological solution
for LED emergency lighting.
Housing specifically designed to
guarantee an IP rating of IP65,
with a modern,
streamlined appearance.
A fixing system with quick-fit
bracket guarantees rapid
installation.
The reflector of the LED logica
range has been designed with
particular care: with the aid of
latest-generation optical system
design software, the special
characteristics of LED lighting
have been optimised, reproducing
a minimal geometric form which
provides total control of light
reflections.
An excellent performance
in terms of average flow,
uniformity and illumination
dimensions.
The technological future
of centralised emergency lighting
Logica LEDwall, ceiling, recessed, false ceiling mounting L
OG
ICA
LED
14
Logica LEDEmergency LED
UV 850°C
GENERAL SPECIFICATIONS
Power 8, 11, 24 W
Operation Non-maintaned (SE), Maintained or
Public Venues (SA/PS)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
Grado�di�protezione IP65
Duration� 1h, 2h, 3h (may be set using the DIP
switch)
Mounting� Wall, ceiling, recessed false ceiling
Housing� RAL 7035 grey polycarbonate
Optic� Symmetrical, in antiglare aluminium
IP65F
230V50Hz
LG HT12 HOURSCHARGING
HHOSPITAL
This emergency luminaire features an extremely sophisticated elec-tronic technology. The Logica LED is the only emergency luminairesupplied as a centralised version (LG, LGFM), with the Autotest (AT)version automatically configuring if it is not connected to a control unit.Individual luminaires can also be manually tested, using a magnet withthe magnetic switch below the screen. This technology makes it pos-sible to immediately test luminaire efficiency.The circuit also allows for the fixture to be customised to require-ments. Duration can be adjusted, (1h/2h/3h) and Maintained versionscan be changed to Public venue versions, adjusting light intensity tothe venue requirements.This provides an excellent solution when safety signs are the onlyobjects that are visible. The sign must be immediately identifiable, sty-lish, minimal and with uniform components.A symmetrical and extremely uniform illumination make the LogicaLED ideal for wall or ceiling mounting, without an established direc-tion, or for recessed mounting, with the kit provided that includes abox and wire cover. The housing contains a dual reflection optic which integrates twoseries of ultra-efficient LEDs to deliver an unprecedented lightingperformance (up to 600 lm). The highly transparent polycarbonatescreen has been designed to seal the optical unit and provide an IPrating of IP65.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
L
B
H170
L1
B1
H1
* Minimum flow guaranteed according to EN 60598-2-22
12182 LOG LED LG 8W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 400/200/150 - 3 - 6
12185 LOG LED LG 8W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 400/200/150 300 3/13 - 6
12183 LOG LED LG 11W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 500/300/200 - 3 - 6
12186 LOG LED LG 11W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 500/300/200 400 3/14 - 6
12184 LOG LED LG 24W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 600/350/250 - 3 - 6
12187 LOG LED LG 24W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 600/350/250 500 3/16 - 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG (AT if not connected to a control unit ) Logica
8
8
11
11
24
24
8 406 147 63 440 170 10 20
11 406 147 63 440 170 10 20
24 406 147 63 440 170 10 20
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • Visibility distance (VD)W L B H L1 B1 H1 screen
TE
ST
12194 Logica lamp grille
12193 Logica false ceiling bracket
12175 Logica RIGHT screen
12176 Logica LEFT screen
12177 Logica DOWN screen
Accessories to be ordered separately
Ordering Code Article
- Logica tube clamp
12198 Recessed box with wire cover frame
12199 Bracket for quick wall mounting
12175 * Logica RIGHT screen
12176 * Logica LEFT screen
12177 * Logica DOWN screen
* only for SA/PS versions
Accessories supplied
Ordering Code Article
15
12194 Logica lamp grille to be ordered separately
LOGICA LUMINAIRE GRID
12175 Logica PS RIGHT screen to be ordered separately
12176 Logica PS LEFT screen to be ordered separately
12177 Logica PS DOWN screen to be ordered separately
LOGICA SCREENS
12198 LOGICA IP65 recessed box provided
RECESSED MOUNTING
12193 Logica false ceiling bracket to be ordered separately
FALSE CEILING AND PLASTERBOARD MOUNTING
Drilling hole template provided:414 x 150 mm
12182FM LOG LED LGFM 8W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 400/200/150 - 4/14 - 6
12185FM LOG LED LGFM 8W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 400/200/150 300 14 - 6
12183FM LOG LED LGFM 11W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 500/300/200 - 4/15 - 6
12186FM LOG LED LGFM 11W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 500/300/200 400 15 - 6
12184FM LOG LED LGFM 24W SE 1/2/3P SE 1/2/3h Pb 6V 4Ah 30 600/350/250 - 4/17 - 6
12187FM LOG LED LGFM 24W SA/PS 1/2/3N SA/PS 1/2/3h NiCd 7,2V 2,2Ah 30 600/350/250 500 17 - 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM (AT if not connected to a control unit) Logica FM Logica FM
8
8
11
11
24
24
* Minimum flow guaranteed according to EN 60598-2-22
17403 LOGICALED HT 8W - - - 30 - 300 3 - 6
17404 LOGICALED HT 11W - - - 30 - 400 6 - 6
17405 LOGICALED HT 24W - - - 30 - 500 11 - 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT HT Powered from the mains (AC 230V 50 Hz - DC 216V)
8
11
24
- REED bulb and magnetic key provided supplied
MAGNETIC SWITCH FOR LOCAL MANUAL DIAGNOSIS
12199 Bracket for quick wall mounting supplied
WALL MOUNTING WITH QUICK-FIT BRACKET AND BUBBLE LEVEL
Recessed mounting hole: 430 x 165 mmLO
GIC
A
LED
16
17
WALL MOUNTING the best illumination the best for signs and Public VenuesThe combination of a reflector with an outstanding perfor-
mance and a dual series of ultra-efficient LEDs deliver
excellent results. Logica is the Stella Polare product with
the best lighting characteristics, in terms of performance,
uniformity and light beam amplitude, which allows for
distances between installation centres of up to 10 m.
Customisable electronics, even with the PS version, plus
a polycarbonate screen for signs, makes the Logica LED
a revolutionary product for all applications where safety
and public venue signs are fundamentally important.
CEILING MOUNTINGideal photometrics for escape routesThe Logica LED optical system makes lighting efficient
even at a height of three metres, producing a particularly
wide photometric solid, that enables distances between
installation centres of up to 15 m.
RECESSED MOUNTINGa stylish solution even for sign systemsThe kit for flush mounting minimises the impact of emer-
gency and sign systems, providing an attractive solution
for all architectural contexts which require safety signs and
emergency lighting.
LO
GIC
A
LED
18
19
A revolutionary fixture
to express a well-known
concept of minimalist
architecture:
"The most stylish luminaire
is the one you can't see".
This is perfectly embodied
by numerous features such
as the minimal number of lighting
bodies and compact size:
just 12 cm in diameter
and a few millimetres thick.
The fixture also
has an innovative
multifunction design.
Select the lens to radically
change the form
and dimensions
of the illuminated area.
The most stylish luminaire
is the one you can't see
Lungalargaluce LEDrecessed
LU
NG
ALA
RG
ALU
CE
LED
B
C(Ø foro)
A
F
230V50HzH
HOSPITAL UV
2020
Fixture for high performance emergency lighting, with specialhigh-transparency plexiglas lenses kit for LG, LGFM and HTversions, for both the Lungaluce and Largaluce versions, toobtain different dimensions of illuminated areas.Each lens has a white polycarbonate cover with fixing systemfor different types of false ceilings. High-efficiency LEDs, die-cast aluminium housing with integrated heat sink.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Lungalargaluce LEDRecessed mounting emergency LED lighting
GENERAL SPECIFICATIONS
Power 24 W
Operation HT, Maintained (SA)/Non-maintained
(SE)/Public Venues (PS) may be selec-
ted with the DIP switch for the LG and
LGFM versions
Conformity UNI 11222, EN 60598-1, EN 60598-2-2,
EN 60598-2-22, CEI EN 62471
IP�rating� IP42
Duration� 1h, 2h, 3h, may be selected with the DIP
switch for the LG and LGFM versions
Mounting� False ceiling, recessed
Housing� RAL 9010 white polycarbonate
Optic� High-transparency plexiglas optical lenses
24 120 28 80 ÷100 204 63 46
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W A B C L G H
- LUNGALUCE lens with cover *
- LARGALUCE lens with cover*
* one lens with AT version, two lenses with LG, LGFM and HT versions
Accessories supplied
Ordering Code Article
IP43
IK07 12 HOURSCHARGING
AT HTLG
* Minimum flow guaranteed according to EN 60598-2-22
19332 L.LARG DW RC LG 24W SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 1/6,5 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
24
19334 L.LARGA DWRC SY AT SE/SA 1/3N SE/SA 1/3h NIMH HT 7.2V 1.2AH AA 3+3 P 1 180 - 1 0,8 6
19335 L.LARGA DWRC ASY AT SE/SA 1/3N SE/SA 1/3h NIMH HT 7.2V 1.2AH AA 3+3 P 1 180 - 1 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
24
19333L.LARG DW RC LGFM 24W SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 2/7,5 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
24
19330 L.LARG DW RC HT 24W - - - 1 - 180 5,5 0,7 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
24
L
H
G
INVERTER AND BATTERIES
LENS Lamps Coverage
LUNGALUCE 3m 1 Covers an escape route of 17.1 m with 1 lux along the centre line and >0.5 lux within 1 metre from the centre line
2 Centre distance of 18m between luminaires covers an escape route of 35.1 m with 1 lux along the centre line and >0.5 lux within 1 m from the centre line
LARGALUCE 3m 1 Covers a surface area of 11.3m x 11.3m at least 0.5lux except for 0.5 m around the perimeter
4 Centre distances of 13.2 m cover a surface area of 24.5m x 24.5m at least 0.5lux except for 0.5 m around the perimeter
H
H
LU
NG
ALA
RG
ALU
CE
LED
2121
3 m
17,1 m
1 lx1 m
SINGLEINSTALLATION
3 m18 m
35,1 m
MULTIPLEINSTALLATION
1 m1 lx 1 lx
11,3 m
11,3 m
3 m
SINGLEINSTALLATION
Area illuminated
by 0,5 lx
24,5 m
24,5 m
3 m13,2 m
13,2 m
Area illuminated
by 0,5 lx
MULTIPLE INSTALLATION
Area illuminated
by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx
Area illuminated
Single installationcovers an escape route of 17.1m with 1 lux along the centre line
and > 0.5 within 1m
Multiple installation, centre distance of 18 m between fixturescovers an escape route of 35.1m with 1 lux along the centre line
and > 0.5 within 1m
Single installation illuminates a surface area of 11.3 x 11.3m at 0.5 lux (128 m2)
Multiple installation, centre distance of 13.2 m between fixtureslights up a surface area of 24.5 x 24.5m at 0.5 lux (600 m2)
LUNGALUCE LENS (ASYMMETRIC BEAM) LARGALUCE LENS (SYMMETRIC BEAM)
Two lenses for several applications
RECESSED MOUNTINGa stylish solution, even for escape routesLungalargaLuce LED is an ideal solution for the safety of lar-
ge areas, and also has an excellent performance with the
Lungaluce lens, where a single fixture can light up a corridor
18 metres long.
Its reduced visual impact is the perfect architectural solution
for prestigious venues. The lighting devices necessary for
emergency lighting are reduced considerably, so the system
is stylishly streamlined, conforms to standards and ensures
considerable cost savings.
22
23
LU
NG
ALA
RG
ALU
CE
LED
24
A revolutionary fixture
to express a well-known
concept of minimalist
architecture:
"The most stylish luminaire
is the one you can't see".
This is perfectly embodied
by numerous features
such as the minimal
number of lighting
bodies and compact size:
just 14 cm long
and 3 cm thick.
The fixture also
has an innovative
multifunction design.
Select the lens to radically
change the form
and dimensions
of the illuminated area.
25
The most stylish luminaire
is the one you can't see
Lungalargaluce LEDceiling mounting
LU
NG
ALA
RG
ALU
CE
LED
26
L
B H
24 137 137 32
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W L B H
Fixture for high performance emergency lighting, with specialhigh-transparency plexiglas lenses kit (for LG, LGFM and HTversions), for both the Lungaluce, Largaluce and Diffusaluceversions, to obtain different dimensions of illuminated areas.Each lens has white polycarbonate housing. High-efficiencyLEDs, die-cast aluminium housing with integrated heat sink.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Lungalargaluce LEDLED emergency luminaire, ceiling mounted
GENERAL SPECIFICATIONS
Power 24 W
Operation� HT, Maintained (SA)/Non-maintained
(SE)/Public Venues (PS) may be
selected with the DIP switch for the
LG and LGFM versions
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI 11222,
CEI EN 62471
IP�rating� IP42
Duration� 1h, 2h, 3h, may be selected with the DIP
switch for the LG and LGFM versions
Mounting� ceiling, wall
Housing� RAL 9010 white polycarbonate
Optic� High-transparency plexiglas optical lenses
- LUNGALUCE lens with cover *
- LARGALUCE lens with cover *
- DIFFUSALUCE lens with cover *
* one lens with AT versions, three lenses with LG, LGFM and HT versions
Accessories supplied
Ordering Code Article
F
230V50HzH
HOSPITAL UV
IP42
IK07 12 HOURSCHARGING
AT HTLG
19322 L.LARG DW CL LG 24W SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 1/6,5 0,6 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
24
19324 L.LARGA DWCL SY AT SE/SA 1/3H SE/SA 1/3h NIMH HT 7.2V 1.2AH AA 3+3 P 1 180 - 1 0,6 6
19325 L.LARGA DWCL ASY AT SE/SA 1/3H SE/SA 1/3h NIMH HT 7.2V 1.2AH AA 3+3 P 1 180 - 1 0,6 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
24
19323 L.LARG DW CL LGFM24W SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 2/7,5 0,6 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
24
H
H
LU
NG
ALA
RG
ALU
CE
LED
27
* Minimum flow guaranteed according to EN 60598-2-22
19320 L.LARG DW CL HT 24W - - - 1 - 180 5,5 0,5 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
24
LENS Lamps Coverage (one hour autonomy)
LUNGALUCE 3m 1 Covers an escape route of 17.1 m with 1 lux along the centre line and >0.5 lux within 1 metre from the centre line
2 Centre distance of 18m between luminaires covers an escape route of 35.1 m with 1 lux along the centre line and >0.5 lux within 1 m from the centre line
LARGALUCE 3m 1 Covers a surface area of 11.3m x 11.3m at least 0.5lux except for 0.5 m around the perimeter
4 Centre distances of 13.2 m cover a surface area of 24.5m x 24.5m at least 0.5lux except for 0.5 m around the perimeter
DIFFUSALUCE 2,5m 1 Covers a surface area of 7m x 3 m at least 0.5lux except for 0.5 m around the perimeter
2 Centre distance of 6.5m covers a surface area of 12m x 3 m at least 0.5lux except for 0.5 m around the perimeter
Thermo-fluid dynamics analysis: calculated heat dissipation
To guarantee a long-lasting, high performance LED source, a new
technology, which simulates the heat diffusion in the fixture, has
been adopted: thermo-fluid dynamics analysis can predict the
operating temperature of various components, in order to optimi-
se the heat dissipation system.
In the case of the Lungalargaluce LED ceiling-mounted version,
the luminaire housing dissipates heat, and is made from die-cast
aluminium to optimise efficiency.
A compact size and quick installation
The Lungalargaluce LED is a concentrated mix of technology hou-
sed in a very compact casing. The outer polycarbonate housing
can easily be removed by operating two quick-release locking
mechanisms, which do not require any specific tools to be ope-
ned. Inside, the housing contains an electronic system comprising
the LED module, inverter and battery set.
A quick-fit terminal block is used for wiring.
28
Lungaluce lens installed at a height of 3m covers an escape route
of 17.1m with 1 lux along the centre line and > 0.5 within 1m
Largaluce lens installed at a height of 3 m illuminates a surface
area of 11.3 x 11.3m at 0.5 lux (128 m2)
Diffusaluce lens A wall mounted diffusa luce lens at a height
of 2.5 m illuminates a surface area of 7 x 3 m at 0.5 lux (21 m2)
Three lenses for several applications
LU
NG
ALA
RG
ALU
CE
LED
29
3 m
17,1 m
1 lx1 m
SINGLE INSTALLATION
3 m18 m
35,1 m
MULTIPLE INSTALLATION
1 m1 lx 1 lx
SINGLEINSTALLATION
2,5 m
7 m
3 mArea illuminated
by 0,5 lx
MULTIPLEINSTALLATION
2,5 m
6,5 m
12 m
3 mArea illuminated by 0,5 lx
11,3 m
11,3 m
3 m
SINGLEINSTALLATION
Area illuminated
by 0,5 lx
24,5 m
24,5 m
3 m13,2 m
13,2 m
Area illuminated
by 0,5 lx
MULTIPLEINSTALLATION
Area illuminated
by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx
Area illuminated
Single installation covers an escape route of 17.1m with 1 lux along the centre lineand > 0.5 within 1m
Multiple installation, centre distance of 18 m between fixturescovers an escape route of 35.1m with 1 lux along the centre line and > 0.5 within 1m
Lungaluce lens - installation at 3 m from the ground
Largaluce lens - installation at 3 m from the ground
Single installation illuminates a surface area of 11.3 x 11.3m at 0.5 lux (128 m2)
Multiple installation, centre distance of 13.2 m between fixtureslights up a surface area of 24.5 x 24.5m at 0.5 lux (600 m2)
Lighting performance on the ground
Diffusaluce lens - installation at 2.5 m from the ground
Single installation illuminates a surface area of 7 x 3 m at 0.5 lux (21 m2)
Multiple installation, centre distance of 13.7 m between fixturesilluminates a surface area of 12 x 3m a 0.5 lux (36 m2)
WALL MOUNTING a small fixture to light up big areasThe wall-mounted version of LungalargaLuce LED, delivers
excellent lighting results for big areas. Thanks to its compact
housing, the system solves emergency lighting problems,
even when installation space is particularly limited.
CEILING MOUNTING a stylish solution, even for escape routesLungalargaLuce LED is an ideal solution for the safety of lar-
ge areas, and with the Lungaluce lens performs brilliantly, illu-
minating a corridor 18 metres long.
The Lungalargaluce LED is the best solution for presti-
gious applications, while it streamlines plant engineering
considerably, in all circumstances, thanks to its stylish
appearance and conformity to standards.
30
31
LU
NG
ALA
RG
ALU
CE
LED
323232
333333
The creative flair of Beghelli
is combined with energy saving,
for solutions that cater for every
kind of installation.
Thanks to an IP rating of IP65
and an innovative, high-efficiency
LED technology combined with
a latest-generation reflector,
the Formula 65 LED
is the all-purpose emergency
lighting product for everyone.
The wide range
of standard fittings
includes a recessed
box with wire cover ends
and safety sign pictograms.
Design and versatility
for numerous applications
Formula65 LEDrecessed, wall mounting
FO
RM
ULA
65
LED
19220 F65 LED 6W IP65 AT SE 1N/RM SE 1 NiCd 4,8V 0,75 Ah 10 70 0,7 0,4 12
19221 F65 LED 6W IP65 AT SE 3H/RM SE 3 NiMH 4,8V 1,7 Ah 10 70 1,5 0,4 12
19222 F65 LED 8W IP65 AT SE 1N/RM SE 1 NiCd 4,8V 0,75 Ah 16 112 0,7 0,6 12
19223 F65 LED 8W IP65 AT SE 3H/RM SE 3 NiMH 4,8V 1,7 Ah 16 112 1,5 0,6 12
19224 F65 LED 8W IP65 AT SA 1N/RM SA 1 NiCd 4,8V 0,75 Ah 16 112 56 1,4 0,6 12
19225 F65 LED 8W IP65 AT SA 3H/RM SA 3 NiMH 4,8V 1,7 Ah 16 112 56 2,7 0,6 12
19226 F65 LED 11W IP65 AT SE 1N/RM SE 1 NiCd 4,8V 0,75 Ah 20 140 0,7 0,6 12
19227 F65 LED 11W IP65 AT SE 3H/RM SE 3 NiMH 4,8V 1,7 Ah 20 140 1,5 0,6 12
19228 F65 LED 11W IP65 AT SA 1N/RM SA 1 NiCd 4,8V 0,75 Ah 20 140 70 1,6 0,6 12
19229 F65 LED 11W IP65 AT SA 3H/RM SA 3 NiMH 4,8V 1,7 Ah 20 140 70 2,9 0,6 12
19230 F65 LED 24W IP65 AT SE 1N/RM SE 1 NiCd 2x4,8V 0,75 Ah 32 224 0,9 0,8 12
19231 F65 LED 24W IP65 AT SE 3H/RM SE 3 NiMH 2x4,8V 1,7 Ah 32 224 2,2 0,8 12
19232 F65 LED 24W IP65 AT SA 1N/RM SA 1 NiCd 2x4,8V 0,75 Ah 32 224 112 2 0,8 12
19233 F65 LED 24W IP65 AT SA 3H/RM SA 3 NiMH 2x4,8V 1,7 Ah 32 224 112 3,7 0,8 12
* Minimum flow guaranteed according to EN 60598-2-22
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
6
6
8
8
8
8
11
11
11
11
24
24
24
24
H
H
H
H
H
H
H
03
03
03
03
03
03
03
03
343434
Formula 65 LEDEmergency LED
Emergency luminaire with an extremely flexible use. Thanks to a sym-metrical and extremely uniform illumination, the Formula 65 LEDs canbe wall, ceiling, double-sided and recess mounted, without a speci-fic direction.The white polycarbonate housing contains a dual reflection opticwhich in turn integrates two series of ultra-efficient LEDs (more than100 lumens/Watt). The highly transparent polycarbonate screen hasbeen designed to seal the optical unit and provide an IP rating of IP65.The outer housing has numerous pre-drilled inlets for direct assemblyon the most widely-available types of connector blocks and recessedboxes.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
IK07IP65
F
230V50Hz12 HOURS
CHARGING
6 354 152 48,5 26 25 m 28 m
8 354 152 48,5 26 25 m 28 m
11 354 152 48,5 26 25 m 28 m
24 354 152 48,5 26 25 m 28 m
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • Visibility distance (VD)W L B H H1 pictogram double-sided
L
B
H H1
HHOSPITAL 850°C UV
AT
GENERAL SPECIFICATIONS
Power 6, 8, 11, 24 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838, UNI 11222
Grado�di�protezione IP65
Duration� 1h, 3h
Mounting� Recessed, wall, ceiling, false ceiling, wall
double-sided and ceiling double-sided
Housing� RAL 9003 white polycarbonate
Optic� White, symmetrical optic
IPPLUG
19041 FALSE CEILING BRACKET F65
19045 WALL BRACKET FOR DOUBLE-SIDED SCREEN F65
19042 DOUBLE-SIDED RIGHT/LEFT SCREEN F65
19043 DOUBLE-SIDED DOWN SCREEN F65
19044 ADES RIGHT LEFT DOWN F65
Accessories to be ordered separately
Ordering Code Article
- Formula 65 tube clamp
19040 Recessed box + frames F65
19044 ADES RIGHT LEFT DOWN F65 (only for SA versions)
Accessories supplied
Ordering Code Article
353535
19040 Recessed box + frames provided F65 provided
RECESSED MOUNTING
19045 Wall bracket to be ordered separately
19042 Double-sided RIGHT/LEFT to be ordered separately
19043 Double-sided DOWN screen to be ordered separately
DOUBLE-SIDED MOUNTING
WALL MOUNTING WITH BUBBLE LEVEL, CEILING MOUNTING WALL MOUNTING LED
- Formula 65 1 TUBE CLAMP 1
19041 False ceiling bracket F65 to be ordered separately
19042 Flag screenDX/SX to be ordered separately
19043 Double-sided DOWN screen to be ordered separately
FALSE CEILING RECESSED DOUBLE-SIDED MOUNTING
19041 False ceiling bracket F65 to be ordered separately
FALSE CEILING RECESSED MOUNTING
- 3 IP PLUG wiring membranes provided
IP PLUG WIRING MEMBRANE
Recessed mounting hole: 370 x 130 mm
FO
RM
ULA
65
LED
WALL MOUNTING diffused emergency light, versatile and glarefree.The amplitude of the photometric solid makes the Formula
65 LED Beghelli an optimal solution for lighting different
areas, in compliance with ATEX directive requirements.
The housing has all possible inlets: right side, left side,
top, bottom and rear. The latter allows for hidden wiring,
even when systems already exist, using the support on a
503-506 box and on all main European and American
standards
CEILING MOUNTINGideal photometrics for escape routesThe Formula 65 LED has a symmetrical optic system
comprising two series of ultra-efficient, miniature
LEDs (over 100 lumens/Watt) to make it effective at over
3 metres high, and particularly suitable for ceiling
installations.
RECESSED MOUNTINGa stylish solution even for sign systemsThe practical recessed box further reduces the compact
size of the system. This configuration minimises the
impact of emergency and sign systems, providing an
attractive solution for all architectural contexts which requi-
re safety signs and emergency lighting.
MOUNTING WITH DOUBLE-SIDED SIGNfor ceiling or wall pictograms and emergency lightThe Formula 65 LED is a highly flexible luminaire.
Thanks to the double-sided screen, the luminaire can be
ceiling or wall mounted, to illuminate the area below, as an
emergency light, and the optional exit sign screen (Down,
Right, Left), to indicate safety exits and escape routes.
Plus, screen dimensions ensure visibility at 28 metres, as
required by UNI EN1838
36
37
FO
RM
ULA
65
LED
38
39
A sleek, versatile solution
for numerous applications
Design Tech LEDrecessed, wall mounting
Beghelli has created
a sleek,
versatile solution,
for emergency lighting
that caters
for different applications.
The contemporary,
elegant appeal
of this fixture makes
it ideal as an
architectural element,
or for recessed
installation
until it operates
in the case
of blackouts.
DES
IGN
TEC
H
LED
3733 RECESSED BOX
4278 ADES 3 LEFT RIGHT DOWN DESIGN LED TECH
Accessories supplied
Ordering Code Article
4266 DESIGN FALSE CEILING BRACKET
4277 DESIGN WALL BRACKET FOR DOUBLE-SIDED MOUNTING
Accessories to be ordered separately
Ordering Code Article
* Minimum flow guaranteed according to EN 60598-2-22
4270 DESIGN LED TECH AT 6W SE 1N SE 1h NiCd 4,8V 0,75 Ah 10 82 - 0,7 0,5 6
4271 DESIGN LED TECH AT 8W SE 1N SE 1h NiCd 4,8V 0,75 Ah 16 131 - 0,7 0,5 6
4279 DESIGN TECH LED AT 8W SE/SA 3N SE/SA 3h NiCd 4,8V 0,75 Ah 32 262 - 0,9 0,6 6
4272 DESIGN LED TECH AT 11W SE 1N SE 1h NiCd 4,8V 0,75 Ah 20 164 - 0,7 0,5 6
4273 DESIGN LED TECH AT 11W SA 1N SA 1h NiCd 4,8V 0,75 Ah 20 164 70 1,6 0,5 6
4274 DESIGN LED TECH AT 24W SE 1N SE 1h NiCd 4,8V 0,75 Ah 32 262 - 0,9 0,6 6
4280 DESIGN TECH LED AT 24W SE/SA 3N SE/SA 3h NiCd 4,8V 0,75 Ah 32 262 - 0,9 0,6 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
6
8
8
11
11
24
24
40
An attractively designed fixture for emergency lighting, which is extre-mely flexible and hi-tech. Thanks to a symmetrical and extremelyuniform illumination, the Design LED can be wall, ceiling, double-sided and recessed mounted, without a specific direction. The poly-carbonate housing contains a dual reflection high diffusion (99.99%)aluminium optic which in turn integrates two series of ultra-efficientLEDs (more than 100 lumen/watt). The tempered glass screen has ametal frame with mirror finish for a particularly attractive look. Theouter housing has numerous pre-drilled inlets for direct assembly onthe most widely-available types of connector blocks and recessedboxes. Double-sided screen version available, for wall and ceilingmounting.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Design Tech LEDEmergency LED
GENERAL SPECIFICATIONS
Power 6, 8, 11, 24 W
Operation Maintained/Non-Maintained (SA/SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
IP�rating� IP40
Duration� 1h
Mounting Wall, ceiling, recessed, false ceiling,
double -sided
Housing� Metallic grey polycarbonate
Optic� Satin finish aluminium symmetrical
Screen� High-transparency tempered glass screen
with mirror finish metal frame
L
B
H
F
230V50Hz
IP4012 HOURSCHARGING 850°C UV
6 292 102 36,8 15 m 20 m
8 292 102 36,8 15 m 20 m
11 292 102 36,8 15 m 20 m
24 292 102 36,8 15 m 20 m
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • Visibility distance (VD)W L B H pictogram double-sided
AT
03
03
03
03
03
03
03
* Minimum flow guaranteed according to EN 60598-2-22
4275 B DESIGN TECH AT 11W SA 1N DX/SX SA 1h NiCd 4,8V 0,75 Ah 20 164 70 1,6 0,8 4
4276 B DESIGN TECH AT 11W SA 1N BASSO SA 1h NiCd 4,8V 0,75 Ah 20 164 70 1,6 0,8 4
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT - AutoTest double-sided sign version AutoTest
11
11
3733 recessed box provided
RECESSED MOUNTING
4266 Design false ceiling bracket to be ordered separately
FALSE CEILING OR PLASTERBOARD RECESSED MOUNTING
- bubble level provided
WALL MOUNTING WITH BUBBLE LEVEL, CEILING MOUNTING CEILING MOUNTING
4266 false ceiling bracket to be ordered separately
FALSE CEILING OR PLASTERBOARD DOUBLE-SIDED MOUNTING
41
4277 for flag installation to be ordered separately
FOR FLAG INSTALLATION
Recessed mounting hole: 279 x 94 mm
Recessed mounting hole: 279 x 94 mm
DES
IGN
TEC
H
LED
42
CEILING MOUNTINGideal photometrics also for escape routes The design LED delivers an excellent lighting performance
with a compact and extremely stylish housing. The poli-
shed effect reflector increases performance and produces
a photometric solid that is particularly wide-ranging, ena-
bling long distances between installation centres.
WALL MOUNTING a focus on style without foregoing lighting performanceThe attractive design of the fixture is particularly noticeable
with wall installations, offering a stylish solution for escape
routes and emergency lighting. Various wiring solutions
are possible for installation: the housing has right side, left
side, top, bottom and rear inlets. The latter configuration
allows for installation, even when systems already exist,
using the support on a 503-506 box and all main
European and American standards.
RECESSED MOUNTINGwhen style is a priorityThis version, which is possible with the recessed box
provided, reduces the impact of emergency luminaires and
sign systems, for an extremely prestigious solution.
MOUNTING WITH DOUBLE-SIDED SIGNfor ceiling or wall pictograms and emergency lightThe Design LED is an extremely flexible fixture. Thanks to
the double-sided screen, the fixture can be ceiling or wall
mounted, to illuminate the area below, as an emergency
light, and the optional exit sign screen (Down, Right, Left),
to indicate safety exits and escape routes.
43
DES
IGN
TEC
H
LED
4444
4545
The latest-generation
luminaire for emergency
lighting and escape
route lighting
for civil and commercial
applications.
The entire range
has been designed
with a whole host
of accessories as standard,
for installation with
the most widely-available
civil lighting ranges.
Frutto Luce 1 has
all the lighting characteristics
of the range, yet uses
a very small amount of space:
the first emergency lighting
system housed
in one 503 box module
Emergency lighting and exit sign
in a very small space
Fruttoluce 1 LED
FR
UTTO
LU
CE
LED
46
FruttoLuce1 is an emergency lighting system that can also be used asmaintained lighting, and is ideal for residential and commercial appli-cations. A rear dip switch lets you switch from SE (non-maintained) toSA (maintained) mode, as required. Plus, an induced light photosen-sor automatically operates the luminaire in SA mode as soon as theambient light threshold decreases, activating "night-time" mode. The characteristic louver has been designed to direct all light produ-ced to the ground as uniformly as possible, to avoid dazzling peoplein the surrounding area. Standard�accessories�include�supporting�frames,�for�instal-
lation�with�all�the�most�widely-available�civil�lighting�ranges.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Fruttoluce 1 LEDEmergency LED
GENERAL SPECIFICATIONS
Power 0,5 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22
IP�rating� IP40
Duration� 1h
Mounting� wall mounting as escape route lighting
wall mounting as night-time lighting
wall mounting as emergency lighting
Housing� Polycarbonate
Optic� Metallic, asymmetrical
F
230V50HzIP40
TR
HB
L
* Minimum flow guaranteed according to EN 60598-2-22
4601 FRUTTOLUCE1 LED SE/SA 1N SE/SA 1h LiFe 3V 0.3A 1 - - - 0,1 12
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Conventional
0,5
0,5 41 41 56,5 non-detachable
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • NotesW L B H
- ADAPTERS FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
Accessories supplied
Ordering Code Article
47
- supporting frames provided
ADAPTERS FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
29 cm
60 cm
20 cm
5 cm 170 cm
320 cm
26 cm
100 cm
Light beam for escape route lighting Light beam for night-time or emergency lighting
The main optic, with multiple louver con-
figuration, has been designed to maximi-
se ground lighting. The reflector, with
complex faceting, focuses all the light
from the FruttoLuce1 to a ground area in
front of the luminaire.
If the luminaire is positioned approxima-
tely one metre from the ground, the light
area is sufficient as emergency lighting. If
instead, the luminaire is positioned at a
height of 20 cm, it can be used as esca-
pe route lighting with light projected in
the direction required.
Mains LED, looking at the luminaire from
any direction. The light from the LED is
reflected numerous times inside the opti-
cal system, guaranteeing visibility from any
viewpoint.
Induced light photosensor. Allows automa-
tic operation of the luminaire in SA (main-
tained) mode, as soon as the ambient light
threshold lowers.
THREE, HIGH-TECHNOLOGY REFLECTORSThe fixture has been specifically designed to illuminate a particular ground area. The reflector design is the main feature of the fixture; in high-reflectance metallized
polycarbonate, the reflector comprises three different optics:
FR
UTTO
LU
CE
LED
MOUNTING WITH THE MOST WIDELY-AVAILABLE CIVIL LIGHTING BOXESFruttoLuce can be mounted low down as escape route
lighting, or high up as emergency lighting for domestic
applications. In both cases, standard accessories include
polycarbonate frames to use as adapters for installation in
503 and 506 boxes from the most widely-available civil
lighting ranges.
48
49
FR
UTTO
LU
CE
LED
5050
5151
The latest-generation
luminaire for emergency lighting
and escape route lighting
for civil and commercial
applications.
The entire range
has been designed
with a whole host
of accessories as standard,
for installation with the most
widely-available
civil lighting ranges.
Frutto Luce 2
has all the lighting
characteristics of the range,
yet uses a very small amount
of space, occupying 2,
503 box modules.
Design and technology
for the most widely-available
civil lighting ranges
Fruttoluce 2 LED
FR
UTTO
LU
CE
LED
52
FruttoLuce2 LEDEmergency LED
GENERAL SPECIFICATIONS
Power 0,5 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22
IP�rating� IP40
Duration� 1h
Mounting� Wall mounting as escape route lighting
Wall mounting as night-time lighting
Wall mounting as emergency lighting
Housing� Polycarbonate
Optic� Metallized asymmetrical
FruttoLuce2 is an emergency luminaire that can also be used asmaintained lighting, and is ideal for residential and commercial appli-cations. A rear dip switch lets you switch from SE (non-maintained) toSA (maintained) mode, as required. Plus, an induced light photosen-sor automatically operates the luminaire in SA mode as soon as theambient light threshold decreases, activating "night-time" mode.The characteristic louver has been designed to direct all light produ-ced to the ground as uniformly as possible, to avoid dazzling peoplein the surrounding area. Standard�accessories�include�supporting�frames,�for�instal-
lation�with�all�the�most�widely-available�civil�lighting�ranges.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
HL
B
F
230V50HzIP40
TR
* Minimum flow guaranteed according to EN 60598-2-22
4602 FRUTTOLUCE2 LED SE/SA 1N SE/SA 1h NiCd 2.4V 0.4A 1 - - - 0,13 12
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Conventional
0,5
0,5 41 41 56,5 non-detachable
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • NotesW L B H
- ADAPTERS FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
Accessories supplied
Ordering Code Article
26 cm
60 cm
20 cm
6 cm 130 cm
340 cm
30 cm
100 cm
Light beam for escape route lighting Light beam for night-time or emergency lighting
The main optic, with multiple louver con-
figuration, has been designed to maximi-
se ground lighting. The reflector, with
complex faceting, focuses all the light
from the FruttoLuce1 to a ground area in
front of the luminaire.
If the luminaire is positioned approxima-
tely one metre from the ground, the light
area is sufficient as emergency lighting. If
instead, the luminaire is positioned at a
height of 20 cm, it can be used as esca-
pe route lighting with light projected in
the direction required.
Mains LED, looking at the luminaire from
any direction. The light from the LED is
reflected numerous times inside the opti-
cal system, guaranteeing visibility from any
viewpoint. Induced light photosensor.
Allows automatic operation of the luminai-
re in SA (maintained) mode, as soon as the
ambient light threshold lowers.
THREE, HIGH-TECHNOLOGY REFLECTORS The fixture has been specifically designed to illuminate a particular ground area. The reflector design is the main feature of the fixture; in high-reflectance metallized
polycarbonate, the reflector comprises three different optics:
53
- supporting frames provided
ADAPTERS FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
FR
UTTO
LU
CE
LED
54
WALL MOUNTING WITH THE MOST WIDELY-AVAILABLE CIVIL LIGHTING BOXESFruttoLuce can be mounted low down as escape route
lighting, or high up as emergency lighting for domestic
applications.
Standard accessories include polycarbonate frames to
use as adapters for installation in 503 and 506 boxes from
the most widely-available civil lighting ranges.
55
FR
UTTO
LU
CE
LED
5656
5757
The latest-generation
luminaire for emergency
lighting and escape
route lighting for civil
and commercial applications.
The entire range
has been designed
with a whole host
of accessories as standard,
for installation with
the most widely-available civil
lighting ranges.
Frutto Luce 3 can be removed
and used as a portable lamp.
Design and technology in
a removable emergency
luminaire extractable, to install
with the most widely-available
civil lighting ranges.
Fruttoluce 3 LED
FR
UTTO
LU
CE
LED
58
FruttoLuce3 LEDEmergenza LED portatile
GENERAL SPECIFICATIONS
Power 0,5 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22
IP�rating� IP40
Duration� 1h
Mounting� Wall mounting as escape route lighting
Wall mounting as night-time lighting
Wall mounting as emergency lighting
Housing� Polycarbonate
Optic� Metallized asymmetrical
FruttoLuce3 is an emergency lighting system that can also be usedas maintained lighting, and is ideal for residential and commercialapplications. A rear dip switch lets you switch from SE (non-maintai-ned) to SA (maintained) mode, as required. Plus, an induced lightphotosensor automatically operates the luminaire in SA mode assoon as the ambient light threshold decreases, activating "night-time"mode.The characteristic louver with diamond faceting has been designed tomaximise all light produced in the surrounding area with an illuminan-ce which is as uniform as possible. The patented locking system forthe detachable part allows for quick detachment, so the luminaire canbe used as a portable torch; the dual snap on/off clip means thetorch can easily be put back after use, and protects the power sup-ply inner terminals when the torch is in use.Standard� accessories� include� a� specific� fixing� system� for
503�boxes,�for�installation�with�all�the�most-widely�available
civil�lighting�ranges.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
0,5 112 65 60 66 39 44
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W L B H L1 B1 H1
B
H
L
B1
H1
L1
F
230V50HzIP40
TR
* Minimum flow guaranteed according to EN 60598-2-22
4603 FRUTTOLUCE3 LED SE/SA 1N SE/SA 1h NiCd 4.8V 0.4A 1 - - - 0,2 12
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Conventional
0,5
- ADAPTERS FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
Accessories supplied
Ordering Code Article
59
The dual snap on/off clip ensures contact with the power supply terminals,
when the fixture is not used as a torch
When the luminaire is used as a torch, the closing system prevents access
to the power supply terminals
Mains LED
Light-sensitive photosensor
to enable SA (maintained) Torch on/off button
SE/SA (non-maintained/
maintained) selector
Detachable torch for domestic useFruttoLuce3 can easily be detached from its housing, to have light where you need it. The
locking system makes it easy to remove the torch, guaranteeing utmost safety for the power
supply terminal block.
- Adapter provided
ADAPTER FOR THE MOST WIDELY-AVAILABLE CIVIL LIGHTING RANGES
FR
UTTO
LU
CE
LED
WALL MOUNTING, ALSO AS A DETACHABLE TORCHFruttoLuce3 is the only fixture in the FruttoLuce range with
a symmetrical light beam, so it can also be used for
domestic emergency lighting.
This function covers the entire house, as the luminaire can
be detached and used as a portable torch in the case of
black outs.
Standard accessories include a polycarbonate adapter for
installation in 503 boxes of the most widely-available civil
lighting switch ranges.
60
61
FR
UTTO
LU
CE
LED
6262
6363
The latest-generation
luminaire for emergency lighting
and escape route lighting
for civil and commercial
applications.
The entire range
has been designed with
a whole host of accessories
as standard, for installation
with the most widely-available
civil lighting ranges.
Frutto Luce 6 can
be installed outdoors,
thanks to the accessory
which gives it an
IP rating of IP55
Design and technology
for the most widely-available
civil lighting ranges
Fruttoluce 6 LED
FR
UTTO
LU
CE
LED
64
FruttoLuce6 is an emergency lighting system that can also be usedas maintained lighting, and is ideal for residential and commercialapplications. A rear dip switch lets you switch from SE (non-maintai-ned) to SA (maintained) mode, as required. Plus, an induced lightphotosensor automatically operates the luminaire in SA mode assoon as the ambient light threshold decreases, activating "night-time"mode. The characteristic louver has been designed to direct all lightproduced to the ground as uniformly as possible, to avoid dazzlingpeople in the surrounding area. The installation counter plate has drilled fixing holes, for installationwith all the most widely-available civil lighting ranges. The metal pro-tection plate can be installed, for an IP rating of IP54. With this acces-sory, the fixture can also be installed in outdoor areas.Standard� accessories� include� a� specific� fixing� system� for
506�boxes,�for�installation�with�all�the�most-widely�available
civil�lighting�switch�ranges.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
FruttoLuce6 LEDEmergenza LED
GENERAL SPECIFICATIONS
Power 2x0,5 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22
Grado�di�protezione IP40 - IP65
Duration� 1h
Mounting� Wall mounting as escape route lighting
Wall mounting as night-time lighting
Wall mounting as emergency lighting
Housing� Polycarbonate
Optic� Metallized asymmetrical
B
H
L
2x0,5 187 70 40 non-detachable
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • NotesW L B H
F
230V50Hz
IP40IP55
TR
* Minimum flow guaranteed according to EN 60598-2-22
4605 FRUTTOLUCE6 LED 4605-SE/SA 1N SE/SA 1h NiCd 4.8V 0.4A 2 - - - 0,2 12
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Conventional
0,5
4620 recessed box 6 components
4621 standard cover plate
4622 IP55 vandal proof plate
4623 IP55 vandal proof plate
Accessories to be ordered separately
Ordering Code Article
65
28 cm
84 cm
6 cm
20 cm
140 cm
420 cm
100 cm
30 cm
Light beam for escape route lighting Light beam for night-time or emergency lighting
Compatible with themost-widely availablecivil lighting rangesAll products in the FruttoLuce range have
specific fixing systems for use with plates
of the most widely-available civil lighting
ranges.
4620 recessed box with 6 components to be ordered separately
the product can be installed in widely-available 506 boxes
RECESSED BOX WITH 6 COMPONENTS
The main optic, with multiple louver con-
figuration, has been designed to maximi-
se ground lighting. The reflector, with
complex faceting, focuses all the light
from the FruttoLuce1 to a ground area in
front of the luminaire.
If the luminaire is positioned approxima-
tely one metre from the ground, the light
area is sufficient as emergency lighting. If
instead, the luminaire is positioned at a
height of 20 cm, it can be used as esca-
pe route lighting with light projected in
the direction required.
Mains LED, looking at the luminaire from
any direction. The light from the LED is
reflected numerous times inside the opti-
cal system, guaranteeing visibility from any
viewpoint.
Induced light photosensor. Allows automa-
tic operation of the luminaire in SA (main-
tained) mode, as soon as the ambient light
threshold lowers.
THREE HIGH-TECHNOLOGY REFLECTORS FOR A UNIQUE FIXTUREThe fixture has been specifically designed to illuminate a particular ground area. The reflector design is the main feature of the fixture; in high-reflectance metallized
polycarbonate, the reflector comprises three different optics:
4621 standard white cover plate to be ordered separately
STANDARD PLASTIC COVER PLATE
4622 IP55 vandal proof plate in RAL7016 anthracite grey to be ordered separately
4623 IP55 vandal proof plate in RAL7035 light grey to be ordered separately
IP55 VANDAL PROOF PLATE IN DIE-CAST ALUMINIUM
FR
UTTO
LU
CE
LED
66
OUTDOOR INSTALLATIONWith its vandal proof IP55 counter plate in die-cast alumi-
nium, the FruttoLuce 6 can be used as outdoor escape
route lighting, considerably increasing its possible uses.
MOUNTING WITH THE MOST WIDELY-AVAILABLECIVIL LIGHTING BOXESFruttoLuce can be mounted low down as escape route
lighting, or high up as emergency lighting for domestic
applications. Fruttoluce 6 has a polycarbonate frame hou-
sing fixing systems for installation in 506 boxes of the
most widely-available civil lighting switch ranges.
67
FR
UTTO
LU
CE
LED
686868
696969
An IP65 luminaire
which combines
a sleek profile
with a particularly
attractive optical system,
that is bound to be noticed.
Ideal for particularly
hi-tech or modern
environments, while flush-
mounting means
it can satisfy the most
discerning style needs.
GranluceLED is eco-friendly
and offers energy saving:
the battery charging system
constantly monitors
remaining energy levels,
to reduce absorption once
the complete cycle has ended.
Design and versatility
for numerous applications
Granluce LED1 LED, 2LED version
GR
AN
LU
CE
LED
70
Fixture with an excellent lighting performance. LED light source withcontrolled beam lens. Monolithic optical assembly to protect fromdust. Polycarbonate housing, high transparency screen. WIde-beamlouver in metallized polycarbonate with complex faceting geometryand sequential reflection planes. Expanded EPDM sealing gasket,resistant to ageing and atmospheric agents.High-efficiency electronic circuit with SE (non-maintained) and SA(maintained) versions, and 1 or 3 hours' duration.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Granluce LED 6-11 WEmergency LED
GENERAL SPECIFICATIONS
Power 6, 11 W
Operation Maintained (SA), Non-maintained (SE)
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
IP�rating� IP65
Duration� 1h, 3h
Mounting� Wall, false ceiling, recessed
Housing� RAL 9010 white polycarbonate
Optic Complex faceting,
asymmetrical metallized
L H
B
L1
B1
H1
6
6
11
11
H
H
03
03
03
03
* Minimum flow guaranteed according to EN 60598-2-22
12950 GRANLUCE LED IP65 AT 6W SE1NRM SE 1h NiCd 4.8V 0.75Ah 1 58 - 0,2 0,6 12
12951 GRANLUCE LED IP65 AT 6W SE3NRM SE 3h NiCd 4.8V 1.7Ah 1 58 - 0,2 0,7 12
12956 GRANLUCE LED IP65 AT 11WSE1NRM SE 1h NiCd 4.8V 0.75Ah 1 82 - 0,2 0,6 12
12957 GRANLUCE LED IP65 AT 11WSE3NRM SE 3h NiCd 4.8V 1.7Ah 1 82 - 0,2 0,7 12
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
F
230V50Hz
IP65H
HOSPITAL
12 HOURSCHARGING850°C UV
AT
6 213 155 52 240 184 25
11 213 155 52 240 184 25
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W L B H L1 B1 H1
3727 tube clamp PG16/PG20 4003/RG
Accessories supplied
Ordering Code Article
12942 Recessed kit 6,11 W
Accessories to be ordered separately
Ordering Code Article
71
2,5 m
1 m
y (centre distance)
LIGHT BEAM 6-11 W
6 W 11 W
y 5 m 5, 5 m
INSTALLATION FOR WALL MOUNTED ESCAPE ROUTE SIGNS INSTALLATION FOR CEILING MOUNTED ESCAPE ROUTE SIGNS
3 m
1 m
x (centre distance)
LIGHT BEAM 6-11 W
6 W 11 W
x 4 m 4 m
12942 RECESSED KIT 6, 11W to be ordered separately
RECESSED MOUNTING
3727 tube clamp PG16/PG20 4003/RG provided
IP65 WALL MOUNTING
WALL MOUNTING CEILING MOUNTING
GR
AN
LU
CE
LED
WALL MOUNTING the only diffused beam with asymmetrical directionThe asymmetrical configuration of the light beam ensures
excellent results with wall mounting. The amplitude of the
photometric solid makes the Granluce LED an optimal
solution for lighting different areas, in compliance with
standards.
CEILING MOUNTINGwhen ceiling space does not allow for drop down installationsWith ceiling mounting, the light beam is not aligned with
the position of the luminaire. Granluce LED ensures an
excellent uniform illumination and long distances between
installation centres, plus it solves architectural or installa-
tion problems when fixtures cannot be installed in the
middle of the area to be illuminated. The misalignment
compared to the illuminated area, at a height of 3 metres,
is approximately 2 metres
RECESSED MOUNTINGa frame for flush mountingThe practical recessed box minimises the impact of emer-
gency lighting and sign systems, for a stylish solution, with
reduced visual impact.
72
73
GR
AN
LU
CE
LED
74747474
Fixture with an excellent lighting performance. LED light source withcontrolled beam lens. Monolithic optical assembly to protect fromdust. Polycarbonate housing, high transparency screen. Wide-beamlouver in metallic polycarbonate with complex faceting geometry andsequential reflection planes. Expanded EPDM sealing gasket, resi-stant to ageing and atmospheric agents.High-efficiency electronic circuit with SE (non-maintained) and SA(maintained) versions, and 1 or 3 hours' duration.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Granluce LED 8-18-24 WEmergency LED
8
8
8
8
18
18
18
18
24
24
24
24
H
H
H
H
H
03
03
03
03
03
03
03
03
03
03
03
GENERAL SPECIFICATIONS
Power 8, 18, 24 W
Operation Maintained (SA),
Non-maintained (SE), HT
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
IP�rating� IP65
Duration� 1h, 3h
Mounting� Wall, false ceiling, recessed
Housing� RAL 9010 white polycarbonate
Optic Complex faceting,
asymmetrical metallized
* Minimum flow guaranteed according to EN 60598-2-22
12952 GRANLUCE LED IP65 AT 8W SE1NRM SE 1h NiCd 6V 0.75Ah 2 60 - 0,2 0,8 6
12953 GRANLUCE LED IP65 AT 8W SE3NRM SE 3h NiCd 7.2V 1.7Ah 2 60 - 0,2 0,9 6
12954 GRANLUCE LED IP65 AT 8W SA1NRM SA 1h NiCd 6V 0.75Ah 2 60 45 0,3 0,8 6
12955 GRANLUCE LED IP65 AT 8W SA3NRM SA 3h NiCd 7.2V 1.7Ah 2 60 45 0,3 0,9 6
12960 GRANLUCE LED IP65 AT 18WSE1NRM SE 1h NiCd 6V 0.75Ah 2 116 - 0,2 0,8 6
12961 GRANLUCE LED IP65 AT 18WSE3NRM SE 3h NiCd 7.2V 1.7Ah 2 116 - 0,2 0,9 6
12962 GRANLUCE LED IP65 AT 18WSA1NRM SA 1h NiCd 6V 0.75Ah 2 116 75 0,3 0,8 6
12963 GRANLUCE LED IP65 AT 18WSA3NRM SA 3h NiCd 7.2V 1.7Ah 2 116 75 0,3 0,9 6
12964 GRANLUCE LED IP65 AT 24WSE1NRM SE 1h NiCd 4.8V 1.7Ah 2 142 - 0,2 0,8 6
12965 GRANLUCE LED IP65 AT 24WSE3NRM SE 3h NiCd 7.2V 1.7Ah 2 142 - 0,2 0,9 6
12966 GRANLUCE LED IP65 AT 24WSA1NRM SA 1h NiCd 4.8V 1.7Ah 2 142 75 0,3 0,8 6
12967 GRANLUCE LED IP65 AT 24WSA3NRM SA 3h NiCd 7.2V 1.7Ah 2 142 75 0,3 0,9 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
8 355 180 58 388 213 30 26 m
18 355 180 58 388 213 30 26 m
24 355 180 58 388 213 30 26 m
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • Visibility W L B H L1 B1 H1 distance
F
230V50Hz
IP65H
HOSPITAL
12 HOURSCHARGING850°C UV
AT HT
L H
B
L1
B1
H1
3727 tube clamp PG16/PG20 4003/RG
12941 * adhesive signs 8,18,24 W
Accessories supplied
Ordering Code Article
12943 Recessed kit 8,18,24 W
Accessories to be ordered separately
Ordering Code Article
12942 RECESSED KIT 6, 11W to be ordered separately
RECESSED MOUNTING
WALL MOUNTINGCEILING MOUNTING
3727 tube clamp PG16/PG20 recessed
IP65 WALL MOUNTING
75757575
2 LED LIGHT BEAM
Sur f ace ar ea 20 mq
I l l umi nance 0, 5 l ux ( on t he gr ound)
EMERGENCY LIGHTING WALL MOUNTING
2 LED LIGHT BEAM
Sur f ace ar ea 12 mq
I l l umi nance 0, 5 l ux ( on t he gr ound)
EMERGENCY LIGHTING CEILING MOUNTING
2,5 m
1 m
y (centre distance)
LIGHT BEAM 8-18 -24 W
8 W 18 W 24W
y 5, 5 m 6, 5 m 7, 5 m
WALL ESCAPE ROUTE MOUNTING FALSE CEILING ESCAPE ROUTE MOUNTING
3 m
1 m
x (centre distance)
LIGHT BEAM 8-18 -24 W
8 W 18 W 24W
x 4, 5 m 5, 5 m 7 m
* Minimum flow guaranteed according to EN 60598-2-22
17422 GRANLUCE 2LED HT IP65 SE/SA 1-3h - 2 - - - 0,8 1
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
3,6
GR
AN
LU
CE
LED
76
WALL MOUNTING the only diffused beam with asymmetrical directionThe asymmetrical configuration of the light beam ensures
excellent results with wall mounting. The amplitude of the
photometric solid makes the Granluce LED an optimal
solution for lighting different areas, in compliance with
standards.
CEILING MOUNTINGwhen ceiling space does not allow for drop down installationsWith ceiling mounting, the light beam is not aligned with
the position of the luminaire. Granluce LED ensures an
excellent uniform illumination and long distances between
installation centres, plus it solves architectural or installa-
tion problems when fixtures cannot be installed in the
middle of the area to be illuminated. The misalignment
compared to the illuminated area, at a height of 3 metres,
is approximately 2 metres
RECESSED MOUNTINGa frame for flush mountingThe practical recessed box minimises the impact of emer-
gency lighting and sign systems, for a stylish solution, with
reduced visual impact.
77
GR
AN
LU
CE
LED
78
79
A simple, yet innovative
design with a unique style.
The Minimal version
of the Creativa LED
incorporates clean 2D lines
for an essential light
designed from a simple
geometric housing.
The Retrò version
recalls the repetitive
lines of some
architectural styles from the
rationalist movement
of the early twentieth century
which has been adopted
as a reference
for post-modern and
contemporary architecture.
A design of the present,
past and future
Creativa LEDwith the minimal and retro version
CR
EATIV
A
LED
8080
Emergency lighting with the possibility to switch from SE (non-main-tained) to SA (maintained) status and with a duration from 1 h to 3 h.Standard accessories include a quick-fit bracket for easier assembly.The white polycarbonate housing also acts as a reflector.The high-transparency methacrylate screen has a surface finish withsanded effect horizontal stripes, for a softer wall light emission, parti-cularly for maintained use (SA).The fixture is supplied with accessories for two different versions:Minimal and Retrò
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Creativa LEDEmergency LED
GENERAL SPECIFICATIONS
Power 8, 11, 24 W
Operation Maintained (SA), Non-maintained (SE)
jumper selected
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
IP�rating� IP40
Duration� 1h, 3h jumper selected
Mounting� Wall
Housing� RAL 9010 white polycarbonate
Optic� White, symmetrical
IP40 F
230V50Hz12 HOURS
CHARGING
L
B
H
H1L1
B1
8 425 160 33 485 160 33
11 325 160 33 385 160 33
24 425 160 33 485 160 33
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W L B H L1 B1 H1
- pair of smooth, rounded Minimal ends
- pair of joined Retrò ends
Accessories supplied
Ordering Code Article
* Minimum flow guaranteed according to EN 60598-2-22
19401 CREATIVA LED 8W AT SE/SA 1/3N SE/SA 1/3h NiCd 4,8V 0,75Ah 16 112/37 56 2,7 1,3 6
19402 CREATIVA LED 11W AT SE/SA 1/3N SE/SA 1/3h NiCd 4,8V 0,75Ah 20 140/47 70 2,9 1,1 6
19403 CREATIVA LED 24W AT SE/SA 1/3N SE/SA 1/3h 2 x NiCd 4,8V 0,75Ah 32 224/75 112 3,7 1,3 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
8
11
24
AT UV
- pair of smooth, rounded Minimal ends provided
MINIMAL VERSION - SMOOTH ROUNDED ENDS
WALL MOUNTING WITH BUBBLE LEVEL
RETRÒ VERSION - JOINED WITH CONTOURED SURFACE
- quick-fit wall bracket provided
- pair of joined Retrò ends provided
8181
Two designs for one fixture
Each Creativa LED fixture has a dual
end system with a different style.
The Minimal version is entirely smooth
and square, for modern or minimalist architectural styles.
The Retrò version is suitable for more specific needs,
for installation in particularly striking interiors.
Minimal version Retrò version
CR
EATIV
A
LED
WALL MOUNTINGdiffused light, with two different stylesThe symmetrical configuration of the light beam guaran-
tees excellent results also for wall mounting.
The screen with sanded finish effect stripes
prevents glare.
The two designs can be installed using the ends provided,
making the fixture ideal for a wide range of interior appli-
cations.
82
83
CR
EATIV
A
LED
84
85
The benefits of high-efficiency LED
technology combined with
precision studies on lens refraction
have led to a new concept of
emergency lighting.
Based on these principles, the
Inverter with LED module has
come into being. This miniature
emergency lighting device has a
number of accessories for
assembly on standard,
conventional lighting fixtures. The
considerable power of the light
beam is interrupted by a number of
controlled refraction lenses that
can give shape to multifunction
light beams.
Reinventing
emergency lighting
LED Module with incorporated Inverter
MO
DU
LO
LED
CO
N I
NV
ER
TER
Emergency LED module with incorporated Inverter
86868686
A high-performance auxiliary fixture for emergency lighting.Operation is subject to the installation of a traditional lightingfixture where the LED module and relative inverter with batteryset are installed. The kit has 3 special high-transparencyplexiglas lenses, for the Lungaluce Altaluce and Largaluceversions, to obtain different dimensions of illuminated surfaceareas, and allow for an installation height from 3 to 7 metres.Each lens has a RAL 9010 white polycarbonate cover. TheLED module has an elastic clip fastening system for T8 andT5 tubes. The high-efficiency LED has a die-cast aluminiumheat sink.
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139GENERAL SPECIFICATIONS
Power 3 W
Operation HT, Maintained (SA)/Non-maintained
(SE)/Public Venues (PS)
may be selected with the DIP switch
for the LG and LGFM versions
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222
IP�rating� depending on the fixture where
the product is installed
Duration� 1h, 2h, 3h, may be selected with the DIP
switch for the LG and LGFM versions
Installation� on equipment with T5 and T8 tubes
Housing� RAL 9010 white polycarbonate
and aluminium
Optic� High-transparency plexiglas lenses
F
230V50Hz12 HOURS
CHARGING
LED module with lens 18÷58 35 35 33
Inverter - 114 32 22
Battery - 40 70 80 50 4,5
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) • W L L1 L2 B H
L
B
H
H
BL
B
L1L2 L L
H
- 3 lenses: LUNGA, LARGA, ALTA with 3 different covers
- 2 springs for fixing on T8 and T5 tubes
Accessories supplied
Ordering Code Article
19342 MODULE EM LED LG SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 1/6,5 0,2 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
18÷58
19344 MODULE EM LED AT SE/SA 1/3H SE/SA 1/3h NIMH HT 7.2V 1.2AH AA 3+3 P 1 180 - 1 0,2 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
18÷58
19343 MODULE EM LED LGFM SE/SA/PS 1/2/3H SE/SA/PS 1/2/3h NiMH 7.2V 1.2Ah 1 180/180/100 126 2/7,5 0,2 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
18÷58
AT LG HT
LED Module
Battery
Inverter
UVIP40
HHOSPITAL
H
H
LENS Lamps Coverage - one hour autonomy
LUNGALUCE 3m 1 Covers an escape route of 17.1 m with 1 lux along the centre line and >0.5 lux within 1 metre from the centre line
2 Centre distance of 18m between luminaires covers an escape route of 35.1 m with 1 lux along the centre line and >0.5 lux within 1 m from the centre line
LARGA LUCE 3m 1 Covers a surface area of 11.3 m x 11.3 m at least 0.5lux except for 0.5 m around the perimeter
4 Centre distances of 13.2 m cover a surface area of 24.5m x 24.5m at least 0.5lux except for 0.5 m around the perimeter
ALTALUCE 7m 1 Covers a surface area of 12.4m x 12.4m at least 0.5lux except for 0.5 m around the perimeter
4 Centre distance of 14.4 m covers a surface area of 26.8m x 26.8m at least 0.5lux except for 0.5 m around the perimeter
87878787
- Steel clips provided
INSTALLATION ON EQUIPMENT WITH T5 TUBES
- Steel clips provided
INSTALLATION ON EQUIPMENT WITH T8 TUBES
Thermo-fluid dynamics analysis: calculated heat dissipation
To guarantee a long-lasting, high performance LED source, a new
technology has been adopted which simulates heat diffusion in
the fixture: thermo-fluid dynamics analysis can predict the opera-
ting temperature of various components, in order to optimise the
heat dissipation system.
* Minimum flow guaranteed according to EN 60598-2-22
19340 MODULE EM LED HT - - - 1 - 180 5,5 0,2 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
18÷58
LED
MO
DU
LE
WIT
H I
NV
ER
TER
88
The Lungaluce lensinstalled at a height of 3m covers an escape route
of 17.1m with 1 lux along the centre lineand > 0.5 within 1m
The largaluce lensinstalled at a height of 3 m illuminates a surface
area 1 of 11.3 x 11.3m at 0.5 lux
The altaluce lensinstalled at a height of 7 m lights up a surface
area of 12.4 x 12.4m at 0.5 lux
Inverter provided
3,5 V700 mA (SE)350 mA (SA)
battery set
One fixture for several applications
LED
MO
DU
LE
WIT
H I
NV
ER
TER
89
3 m
17,1 m
1 lx1 m
SINGLE INSTALLATION
3 m18 m
35,1 m
MULTIPLEINSTALLATION
1 m1 lx 1 lx
12,4 m
12,4 m
7 m
Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lx
Area illuminated Area illuminated
by 0,5 lx
Area illuminated
SINGLEINSTALLATION
26,8 m
26,8 m
7 m13,7 m
13,7 m
Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lx
Area illuminated Area illuminated Area illuminated Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lxby 0,5 lx
Area illuminated Area illuminated Area illuminated Area illuminated
by 0,5 lxby 0,5 lxby 0,5 lx
Area illuminated Area illuminated Area illuminated Area illuminated
by 0,5 lxby 0,5 lx
Area illuminated
by 0,5 lxby 0,5 lxby 0,5 lxby 0,5 lx
Area illuminated
by 0,5 lxby 0,5 lxby 0,5 lxby 0,5 lxby 0,5 lx
Area illuminated
by 0,5 lx
Area illuminated
by 0,5 lx
MULTIPLEINSTALLATION
11,3 m
11,3 m
3 m
SINGLEINSTALLATION
Area illuminated
by 0,5 lx
24,5 m
24,5 m
3 m13,2 m
13,2 m
Area illuminated
by 0,5 lx
MULTIPLEINSTALLATION
Area illuminated
by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx by 0,5 lx
Area illuminated
Single installationcovers an escape route of 17.1m with 1 lux alongthe centre line and > 0.5 within 1m
Multiple installation, centre distance of 18 m between fixturescovers an escape route of 35.1m with 1 lux along the centre line and > 0.5 within 1m
Lungaluce lens - installation at 3 m from the ground
Largaluce lens - installation at 3 m from the ground
Single installationilluminates a surface area of 11.3 x 11.3m at 0.5 lux (128 m2)
Multiple installation, centre distance of 13.2 milluminates a surface area of 24.5 x 24.5m at 0.5 lux (600 m2)
Lighting performance on the ground
Altaluce lens - installation at 7 m from the ground
Single installationlights up a surface area of 12.4 x 12.4m at 0.5 lux (154 m2)
Multiple installation, centre distance of 13.7 milluminates a surface area of 26.8 x 26.8m at 0.5 lux (718 m2)
90
CEILING MOUNTINGinside standard lighting equipmentThe LED module with inverter has various fixing systems,
for housing in standard lighting equipment.
This new concept of emergency lighting enables existing
lighting systems to be used for a strategic solution in
numerous applications: restructuring work, upgrad ing of
existing systems to regulations, new installations where
the number of lighting devices has to be reduced, and
costs and relative times cut.
Plus with the lenses kit provided, one fixture can be instal-
led at 3 or 7 metres to illuminate an area of more than 150
square metres, or obtain a specific beam to illuminate
a corridor 18 metres long.
91
LED
MO
DU
LE
WIT
H I
NV
ER
TER
92
93
The entire range
of new products
for safety signs features
functionality
and design in a single,
aluminium and glass unit.
With a sleek, minimal profile,
the luminaries are high-tech
compact units with ample
illumination in any ambient
light situation.
The final effect is light
and streamlined,
and an extremely
uniform sign, which is
practically unprecedented
in the lighting industry.
A robust, stylish fixture
for numerous applications
Indica LED 20
IND
ICA
LED
94949494
Indica LED is the design solution for sign lighting requirements, with ahigh technological content for all types of applications. A back lightsystem is used, and thanks to a patented optical system, sign illumi-nation is as uniform as possible, and luminosity is excellent. The fix-ture is particularly versatile as it is supplied with a universal bracketthat can be fitted on the long side, for ceiling mounting, and on theshort side for double-sided wall mounting. A single-sided version isalso available for above door installations. All Indica LED productshave silk-screen printed opaline polycarbonate screens for easierinstallation and a very high single illuminance uniformity (over500cd/m2).
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Indica LED 20mLED sign
GENERAL SPECIFICATIONS
Power 1-2,1 W
Operation HT, Maintained (SA)/Public
Venues (PS) operation, may be
selected with the DIP switch
for the LG and LGFM versions
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, DIN 4844-1
Grado�di�protezione IP42
Duration� 1 h, 2h or 3h duration, jumper selected
for the LG and LGFM versions
Installation� wall, false ceiling, ceiling with brackets,
wall double-sided, ceiling double-sided
Housing� Aluminium and frame and RAL 7035
polycarbonate bracket
Optic� High-efficiency back light optical system
B
L H
B
L H
B
L
H
L
B
H
Wall double-sided version ceiling double-sided versionrecessed single-sided versionwall single-sided version
20 235 135 15
DV L B H
20 235 135 38
DV L B H
20 266 252 36
DV L B H
20 235 166 36
DV L B H
19380 BRACKETS 250MM INDICA DF
19381 BRACKETS 500MM INDICA DF
19382 BRACKETS 1000MM INDICA DF
19383 INDICA DF 2 M WIRE SUSPENSION
19384 20 M FALSE CEILING RECESSED BRACKET
Accessories to be ordered separately
Ordering Code Article
- RIGHT/LEFT/DOWN SCREEN
Accessories supplied
Ordering Code Article
IP42 F
230V50Hz
AT LG HTUNI EN 1838
20 m850°C UV
HHOSPITAL
95959595
Double-sided version
* Minimum flow guaranteed according to EN 60598-2-22
19305 INDICA LED DF20M LG SA/PS 1/2/3H SA/PS 1/2/3h NiMh 7,2V 0,6Ah 32 192/96/64 115 3,5 0,52 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
2,1
19309 IND LED DF20M AT SA/PS 1/3H SA/PS 1/3h NI MH HT 7.2V 0.6AH AAA PACK 32 192 115 3,5 0,52 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
2,1
19307 INDICA LED DF20M LGFM SA/PS 1/2/3H SA/PS 1/2/3h NiMh 7,2V 0,6Ah 32 192/96/64 115 3,5 0,52 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
2,1
19301 INDICA LED DF20M HT - - - 32 - 192 3 0,52 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
2,1
19383 Wire suspension max 100 to be ordered separately
HANGING DOUBLE-SIDED MOUNTING
19384 20 m false ceiling recessed bracket to be ordered separately
FALSE CEILING RECESSED DOUBLE-SIDED MOUNTING
CEILING DOUBLE-SIDED MOUNTING
19380 BRACKETS 250MM INDICA DF to be ordered separately
19381 BRACKETS 500MM INDICA DF
19382 BRACKETS 1000MM INDICA DF
CEILING DOUBLE-SIDED MOUNTING WITH BRACKETS
WALL DOUBLE-SIDED MOUNTING
Recessed hole dimensions: 297 x 43 mm
H
H
IND
ICA
LED
96
INSTALLAZIONE A PARETE
Single-sided version
* Minimum flow guaranteed according to EN 60598-2-22
19315 INDICA LED SF20M LG SAPS 1/2/3H SA/PS 1/2/3h NiMH 7.2V 1.2Ah 16 96/96/55 68 2,6 0,65 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
1
19319 IND LED SF30M AT SA/PS 1/3H SA/PS 1/3h NC+CAB HT 7.2V 0.75AH AA 3+3 P 16 96 58 2,6 0,65 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
1
19317 INDICA LED SF20M LGFM SAPS 1/2/3H SA/PS 1/2/3h NiMH 7.2V 1.2Ah 16 96/96/55 68 2,6 0,65 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
1
19311 INDICA LED SF20M HT - - - 16 - 96 2 0,65 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
1
- adapter for 506 boxes provided
RECESSED WALL MOUNTING ON 50699 BOX
97
QUICK-FIT BRACKET
FOR THE UTMOST INSTALLATION VERSATILITY
The outer edge in extruded aluminium has been designed as a
fixing guide.
This particular configuration makes the Indica LED sturdier and
more rigid, and the fixing bracket can be applied on all sides of
the unit.
The polycarbonate screens can be removed, without using any
special tools.
Simple, versatile and robust - the basic features of the Indica
LED. For unprecedented signal illumination.
Bracket position for double-sided
left mounting
Bracket position
for ceiling mounting
Bracket position for double-sided
right mounting
IND
ICA
LED
98
DOUBLE-SIDED INSTALLATIONwith double-sided or ceiling mounting for the utmost visibility in all directionsThe double-sided version of the Indica LED has a fixingsystem for double-sided or ceiling mounting, thanks tothe special supporting bracket that can be placed alongthe short side (for double-sided mounting) or long side(for ceiling mounting).Signal luminosity is particularly uniform, and definition isexcellent, for all types of installation.
SINGLE-SIDED INSTALLATIONa uniform, high-definition sign,for wall or recessed mountingThe single-sided version of Indica LED has a fixingsystem for direct wall mounting. A frame is provided forspecial architectural needs, to house the rear part of thefixture inside a 506 box. The luminaire is therefore flushmounted, whilst maintaining excellent definition andillumination.
99
IND
ICA
LED
100
The entire range
of new products
for safety signs features
functionality
and design in a single,
aluminium and glass unit.
With a sleek, minimal profile,
the luminaires are high-tech
compact units with ample
illumination in any
ambient light situation.
The final effect
is a streamlined,
sleek profile,
and an extremely
uniform sign,
which is practically
unprecedented
in the lighting industry.
A robust, stylish fixture
for numerous applications
Indica LED 30
101
IND
ICA
LED
102
Indica LED is the design solution for sign lighting requirements, with ahigh technological content for all types of applications. A back lightsystem is used, and thanks to a patented optical system, sign illumi-nation is as uniform as possible, and luminosity is excellent. The fix-ture is particularly versatile as it is supplied with a universal bracketthat can be fitted on the long side, for ceiling mounting, and on theshort side for double-sided wall mounting. A single-sided version isalso available for above door installations. All Indica LED productshave silk-screen printed opaline polycarbonate screens for easierinstallation and a very high sign illuminance uniformity (over500cd/m2).
Photometrics and Luce Utile page 130, Symbols page 142, Spare batteries page 139
Indica LED 30mLED signs
GENERAL SPECIFICATIONS
Power 1,6-3,2 W
Operation HT, Maintained (SA)/Public Venues (PS)
operation, may be selected with the DIP
switch for the LG and LGFM versions
Conformity EN 60598-1, EN 60598-2-2,
EN 60598-2-22, UNI EN 1838,
UNI 11222, DIN 4844-1
IP�rating� IP42
Duration� 1 h, 2h or 3h duration, jumper selected
for the LG and LGFM versions
Mounting� wall, false ceiling, ceiling with brackets,
wall double-sided, ceiling double-sided
Housing� Aluminium frame and RAL 7035 poly-
carbonate bracket
Optic� High-efficiency back light optical system
19380 BRACKETS 250MM INDICA DF
19381 BRACKETS 500MM INDICA DF
19382 BRACKETS 1000MM INDICA DF
19383 INDICA DF 2 M WIRE SUSPENSION
19386 30M FALSE CEILING RECESSED BRACKET
Accessories to be ordered separately
Ordering Code Article
- SCREEN DX/SX/BASSO
Accessories supplied
Ordering Code Article
B
L H
B
L H
B
L
H
L
B
H
Wall double-sided version ceiling double-sided versionrecessed single-sided versionwall single-sided version
30 335 185 15
DV L B H
30 335 185 38
DV L B H
30 366 252 36
DV L B H
30 335 216 36
DV L B H
IP42 F
230V50Hz
AT LG HTUNI EN 1838
20 m850°C UV
HHOSPITAL
103
Double-sided version
* Minimum flow guaranteed according to EN 60598-2-22
19304 INDICA LED DF30M LG SA/PS 1/2/3H SA/PS 1/2/3h NiMH 7,2V 1.2Ah 48 288/288/160 205 4,2 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
3,2
19308 IND LED DF30M AT SA/PS 1/3H SA/PS 1/3h NI MH HT 7.2V 0.6AH AAA PACK 48 288 173 4,2 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
3,2
19306 INDICA LED DF30M LGFM SA/PS 1/2/3H SA/PS 1/2/3h NiMH 7,2V 1.2Ah 48 288/288/160 205 4,2 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
3,2
19300 INDICA LED DF30M HT - - - 48 - 288 3,7 0,8 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
3,2
WALL DOUBLE-SIDED MOUNTING CEILING DOUBLE-SIDED MOUNTING
19380 BRACKETS 250MM INDICA DF to be ordered separately
19381 BRACKETS 500MM INDICA DF
19382 BRACKETS 1000MM INDICA DF
CEILING DOUBLE-SIDED MOUNTING WITH BRACKETS
19383 Wire suspension max 100 to be ordered separately
HANGING DOUBLE-SIDED MOUNTING
19384 30 m false ceiling recessed bracket to be ordered separately
FALSE CEILING RECESSED DOUBLE-SIDED MOUNTING
Recessed hole dimensions: 367 x 43 mm
H
H
IND
ICA
LED
104
WALL MOUNTING
Single-sided version
19314 INDICA LED SF30M LG SAPS 1/2/3H SA/PS 1/2/3h NiMH 7,2V 1.2Ah 24 288/288/160 205 3 1,1 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LG Logica
1,6
19318 IND LED SF30M AT SA/PS 1/3H SA/PS 1/3h NC+CAB HT 7.2V 0.75AH AA 3+3 P 24 144 86 3 1,1 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
AT AutoTest
1,6
19316 INDICA LED SF30M LGFM SAPS 1/2/3H SA/PS 1/2/3h NiMH 7,2V 1.2Ah 24 288/288/160 205 3 1,1 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
LGFM Logica FM
1,6
19310 INDICA LED SF30M HT - - - 24 - 144 2,5 1,1 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
HT Powered from the mains (AC 230V 50 Hz - DC 216V)
1,6
* Minimum flow guaranteed according to EN 60598-2-22
- adapter for 506 boxes provided
RECESSED WALL MOUNTING ON 506 BOX
105
QUICK-FIT BRACKET
FOR THE UTMOST INSTALLATION VERSATILITY
The outer edge in extruded aluminium has been designed as a
fixing guide. This particular configuration makes the Indica LED
sturdier and more rigid, and the fixing bracket can be applied on
all sides of the unit. The polycarbonate screens can be removed,
without using any special tools.
Simple, versatile and robust - the basic features of the Indica
LED. For unprecedented signal illumination.
Bracket position
for double-sided left mounting
Bracket position
for ceiling mounting
Bracket position
for double-sided right mounting
IND
ICA
LED
106
107
DOUBLE-SIDED INSTALLATIONwall or ceiling mounting to achieve maximum visibility from any directionThe double-sided version of the Indica LED has a fixingsystem for double-sided or ceiling mounting, thanks tothe special supporting bracket that can be placed alongthe short side (for double-sided mounting) or long side(for ceiling mounting).Signal luminosity is particularly uniform, and definition isexcellent, for all types of installation.
SINGLE-SIDED INSTALLATIONa uniform, high-definition sign,for wall or recessed mountingThe single-sided version of the Indica LED has a fixingsystem for direct wall mounting. A frame is provided forspecial architectural needs, to house the rear part of thefixture inside a 506 box. The fixture is therefore flushmounted, whilst maintaining excellent definition andillumination.
IND
ICA
LED
108
Illumina LED is a contemporary
take on portable torches
for domestic use,
which also combine
emergency lighting.
This fixture has a particular
symbolic value,
as it embodies
the historical
evolution of Beghelli,
which laid the foundations
for its success
in 1982 with the Elegant
Box Light, the first portable
emergency lamp.
Since then, the company
has always focussed
on new technologies, without
foregoing design,
product quality and safety.
Illumina LED perfectly reflects
this concept, with its elegant
design, numerous high power
LEDs and very long battery life,
guaranteeing a duration
of up to 24 hours.
Anti-black out rechargeable
LED luminaires, and battery
charger function
Illumina LED
109
ILLU
MIN
A
LED
L
H B
110
IlluminaLEDPortable LED emergency light
GENERAL SPECIFICATIONS
Power 0,5-1,6 W
Operation 2 torch light intensity levels,
non-maintained (SE)
IP�rating� IP40
Duration� 3h, 6h, 12h, 24h
Mounting� When plugged into the mains, the fixture
works as emergency lighting. When
unplugged, it becomes a torch.
Housing� Glass and polycarbonate
shock-proof ABS
Optic� Metallized, symmetrical
illuminaLED and illuminaLED Ricarica are Beghelli's new anti black-outrechargeable portable luminaires. With 8, high-power LEDs for excel-lent lighting and a very long duration. When connected to the mains,the fixture automatically comes on in the case of black outs. If notconnected to the mains, the fixture becomes a torch with two lightintensity levels, that can be selected from the two-position switch.The integrated rechargeable batteries eliminate the costly problem ofhaving to replace batteries. The long-lasting LEDs guarantee excellentlighting conditions at low maintenance costs, low energy consump-tion and a long duration.The Illumina LED Ricarica version has housing inside the mains wiringcompartment, to charge up to 4 AA or AAA batteries of differentamperages (not included with the fixture) at the same time. The auxi-liary batteries may be used to power other electronic devices or toincrease the duration of the Illumina LED up to a maximum of 24hours.
Symbols page 142
F
230V50HzIP40
3310 Illumina LED Ricarica black - 3/6h NiCd 3,6V - 0,75Ah 8 56 - 0,6 0,42 6
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Illumina LED
0,5
3311 Illumina LED Ricarica nera - 6/12/24*h Pb 6V - 2,8Ah 8 168 - 2,5/3,8 ** 0,88 6
* putting 4 AA 2500 mA batteries in the charging compartment
** absorption when recharging AA or AAA auxiliary batteries
Ordering Code Article Version Duration Battery n° of LEDs Flow* SE lm Flow* SA lm Absorption W Weight kg PackW
Illumina LED Ricarica
1,6
0,5 194 125 39
1,6 194 125 39
** Indicative power for comparison with fluorescent tube lighting
Power** • Dimensions (mm) •W L B H
UV
111
Emergency luminaire
If plugged into a socket and with the selector switched to MIN or
MAX power, Illumina LED automatically comes on in the case of a
black out and goes off when mains power is restored. A green
LED on the luminaire housing shows that the fixture is connected
to the mains.
AA or AAA battery charger (code 3311 only)
The back of the lamp can be opened and contains the power
cable for recharging. The illuminaLED Ricarica model (code 3311)
also has housing to recharge the 4 AA or AAA batteries.
The additional rechargeable batteries may be left inside the lamp
during use, to increase duration to up to 24 hours.
Variable power torch
Select the red button to turn on the lamp and choose from two
lighting levels and durations.
ILLU
MIN
A
LED
IlluminaLED Ricarica are Beghelli's new anti black out rechar-geable portable lamps. With 8, high-power LEDs for excellentlighting and a very long duration. When connected to themains, the fixture automatically comes on in the case of blackouts. If not connected to the mains, the fixture becomes atorch with two light intensity levels, that can be selected fromthe two-position switch.
ILLUMINA LEDThe integrated rechargeable batteries eliminate the costlyproblem of having to replace batteries. The long-lasting LEDsguarantee excellent lighting conditions at low maintenancecosts, low energy consumption and a long duration.
ILLUMINA LED RICARICAThe Illumina LED Ricarica version has housing inside themains wiring compartment, to charge up to 4 AA or AAA bat-teries of different amperages (not included with the fixture) atthe same time.The auxiliary batteries may be used to power other electronicdevices or to increase the duration of the Illumina LED up toa maximum of 24 hours.
112
113
ILLU
MIN
A
LED
114114
Technical
attachment
Design 118
Control systems
AT - AutoTest 120
LG - Logica 121
LGFM - Logica FM 120
Installations
Local control AT 122
Centralised control 124
LG-LGFM
Total quality 126
Installation procedures 128
Photometric diagrams 130and Luce Utile
115115
TEC
HN
ICA
L
ATTA
CH
MEN
T
Simulation of the end result
116
PROGEM calculation software
PROGEM has been developed by Beghelli's research centre for
lighting design. The software programme contains all Beghelli
technical product datasheets for lighting and emergency lighting.
CAD data from other architectural programmes can be processed
and results exported with the utmost ease. The programme is an
effective tool to:
• Create professional and effective designs, as simply as possible
• Calculate emergency lighting that conforms to UNI-EN 1838.
• Calculate bills of quantities
• Display lighting results with ambient rendering
• Define environments, escape routes and emergency areas
Design of the system
Plant/system engineeringSystem layouts, control of anomalies and system management
LOGICA VISUAL management software
Software for the management of one or more centralised emer-
gency lighting systems from the LOGICA, LOGICA FM and
SoccorLogica ranges. Layouts may be imported in standard for-
mats and completed, by positioning the various emergency and
lighting systems. The video interface lets users directly operate
the devices and view their status. All operations possible from the
remote control unit may be carried out: a report on system status
can be automatically generated. Reports can be archived, crea-
ting status tracking for systems.
117
DIALUX calculation software
One of the most widely used lighting software applications world-
wide, for professional lighting design. The application can process
CAD data from other architectural programmes and export results
with the utmost ease. The programme is an effective tool to:
• Create professional and effective designs, as simply as possible
• Produce realistic rendering and video clips
• Carry out energy appraisals
• Recreate lighting and emergency lighting scenes
• Generate technical datasheets for catalogue products
• Define environments, escape routes and emergency areas
• Calculate emergency lighting that conforms to UNI-EN 1838.
Choice of fixture
Design of the system
Simulation of the end result
Choice of fixture
Design of the system
Simulation of the end result
Design
TEC
HN
ICA
L
ATTA
CH
MEN
T
LGFM - Logica FM: the centralised system via radio
LOGICA CT VIA RADIO SYSTEM
(up to 992 fixtures per control unit *)
The LOGICA FM control unit manages and controls emergency
fixtures from the Logica FM range. The LOGICA FM control unit
can be managed and controlled from a remote or local PC.
LOW POWER RADIO COMMUNICATION BASED ON
SPREAD-SPECTRUM TECHNOLOGY
WITH AN UNLIMITED RADIO CAPACITY
The radio waves used by the Logica FM system are very low
power, to avoid any kind of interference and electromagnetic pol-
lution. The power used in radio communication is less than one
hundredth that emitted by a normal
mobile phone.
The signal transmitted from the Control Unit is received by the fir-
st fixture along the "path" stored during the Control Unit start-up
stage; each fixture, fitted with a transceiver and radio amplifier,
receives and transmits the signal of the fixture which follows it
along the stored "path".
All products in this range conform to requirements in the European
Recommendation ERC/REC 70-03.
* the maximum number of units may vary from installation site to site. Please contact our customer support for specific data.
Esc ok
LONLON Personal
Computer
with RS485
Logica printer
(code 12099)
Interfaces available:
USB (code 12136)
ETHERNET (code 12135)
RS232 (code 12134)
GSM interface
(code12132)
LON interface
(code 12140)
LOGICA control unit
(code 12100)
118
AT - Autotest: the integrated control system
ELECTRONICALLY CONTROLLED CHARGING, TO SAVE ENERGY AND DOUBLE BATTERY LIFETIME
The waste of energy caused by continually charging emergency lumi-
naires is often overlooked. Beghelli has always focussed on environ-
mental issues and has developed a charging system that automati-
cally switches to a subsequent stage after a complete battery char-
ging cycle (12 hours), to maintain the charge and reduce lamp
absorption to less than one Watt. This measure considerably reduces
wasted energy, limits heat build-up and consequent battery stress
and thus increases the useful life of batteries by as much as two times
that obtained with conventional circuits.
SIMPLIFIES PROCEDURES REQUIRED BY
UNI 11222
This system guarantees the testing that must be carried out by
the Prevention and Protection Service Manager as required by
Italian Legislative Decree 81/08 on safety in the workplace.
The duration test includes a control of all lamp functions over a
period equal to the duration required by individual standards, and
is conducted every 26 weeks. An operating test on the lamp, bat-
tery and circuit is also carried out, every 28 days. Test results are
displayed by the multicolour LED on the fixtures. This guarantees
proper monitoring of fixture operation at all times and energy
saving on costs for maintenance staff.
POWER SUPPLY
High-efficiency LED
1 MULTICOLOUR LED
BATTERY SWITCH-OVER
MICROPROCESSOR (µP)
119
LG - Logica the centralised multifunction systemAUTOMATES PROCEDURES
REQUIRED BY UNI 11222
LOGICA is a versatile, modular control system for emergency
lighting, designed to ensure compatibility with local and national
regulations on the use and testing of emergency lighting systems.
In particular, standard� 11222� requires� procedures� for� the
periodic� testing,�maintenance,�servicing�and� inspection
of�emergency�fixtures.
- Modular system
- Fixtures that work in AutoTest and Centraltest mode
- Programmable duration (1 hour / 3 hours)
- Tests may be postponed for a part of the system (odd / even)
- Connections either wired (LOGICA) or via radio (LOGICA FM)
- DALI-compatible bus for the management of DALI lighting
fixtures (LOGICA)
- Remote control by PC possible (GSM, Ethernet, USB, RS232
interface)
- Integration with building automation possible
- Centralised configuration operations
- 16 groups of fixtures may be programmed
- 16 lighting scenes may be programmed
- Inverters (Power packs) for:
- Incandescent lamps
- Halogen lamps with electronic and magnetic transformers
- Fluorescent tubes with electronic or magnetic ballast
BUS CENTRALISED LOGICA SYSTEM
VIA THE LOGICA SUPERVISION UNIT
(up to 4096 fixtures)
The LOGICA Supervision Unit can manage up to 32 LOGICA
control units for a total of 4096 emergency lighting fixtures and
DALI lighting fixtures. The LOGICA Supervision Unit can be mana-
ged and controlled from a remote or local PC.
The LOGICA Supervision Unit adds the following functions to the
LOGICA system:
- Programming and centralised management of all connected
Logica Control Units
- Centralised printing of reports
- Logbook (results of functional and duration tests are stored for
two years)
LOGICA CT VIA BUS SYSTEM
(up to 128 fixtures)
The Logica Control Unit can manage Logica range emergency fix-
tures, as well as DALI (Digital Addressable Lighting Interface -
international standard according to IEC60929) fixtures, for up to a
maximum of 128. The number of LOGICA Control Units that can
be connected to a PC is practically unlimited, so the management
and control functions of numerous devices can be grouped
together at one station.
Logica Control Unit code 12100
up to 128
up to 128
up to 128
LOGICA Supervision Unit
(code 12131)
Esc ok
Personal
Computer
with RS485
Logica printer
(code 12099)
Interfaces available:
USB (code 12136)
ETHERNET (code 12135)
RS232 (code 12134)
GSM interface
(code 12132)
LON interface
(code 12140)
Esc ok
LOGICA control unit
(code 12100)
Esc ok
LOGICA control unit
(code 12100)
Esc ok
LOGICA control unit
(code 12100)
LONLON
Control systems
TEC
HN
ICA
L
ATTA
CH
MEN
T
120
1
1
1
1
1
Design�Tech�LEDemergency lamp
3
3
3
2
2
Lungalargaluce�LEDemergency lamp
3
Fruttoluce�LEDemergency lamp
4
Indica LEDemergency lamp
121
Local control system
AT
The simplest system in conformity to UNI 11222
UNI 11222 defines the procedures for the periodic inspection,
maintenance, revision and testing of safety lighting installations in
buildings, comprising autonomous and centralised emergency ligh-
ting fixtures. The Standard requires in practically all cases emergency
lighting fixtures and/or systems that allow for automatic testing and
actual duration.
It also states that the records from automatic self-diagnostics systems are
valid for compiling periodic test records. The use of Autotest fixtures is the-
refore recommended even for moderate-sized systems, which in economic
terms are practically on a same level as standard conventional emergency fixtures.
4
4
2
2
Installation samples
TEC
HN
ICA
L
ATTA
CH
MEN
T
122
2
2
2
3
3
3
5
44
1
1
1
4
4
4
4
4
Lungalargaluce�LEDemergency lamp
1
Lungalargaluce�LEDemergency lamp
Lungaluce
lens
Largaluce
lens
3
Fruttoluce�LEDdetachable emergency lamp
5
Logica�LEDEmergency lighting
6
6
LG-LGFM�control�unitcontrol and diagnostics system
4
Indica LEDilluminated sign
2
3
3
3
3
3
3
3
33
5
4
4
4
4
1
123
Centralised control system
LG - LGFM
Control and management for systems that are self-powered or have a centralised power supply
When a system is of a considerable size (more than 30 - 40 fixtures on average), systems with centrali-
sed auto-diagnostics such as the Logica and Logica FM ranges are recommended.
These have the benefit of grouping periodic test results in one station. The Logica FM system is also extre-
mely convenient as connections in addition to normal power supply cables are not required. This means
that an emergency lighting system with centralised control can even be installed in existing systems,
without making any changes to the wiring, as a dedicated line is not required.
TEC
HN
ICA
L
ATTA
CH
MEN
T
124
Total quality
The creation of LED light sources marked a turning point in all ligh-
ting sectors.
A source which is evenly distributed with any power, temperature
or colour, will help develop applications in the future, in terms of
improving performance and design flexibility.
The issue of energy saving is addressed by using LED sources in
all possible fields of lighting, as they guarantee long-lasting opera-
tion and excellent lighting, plus a drastic reduction in the amount of
energy required to produce the same lighting performance.
Like all revolutionary technologies, the use of LEDs requires ade-
quate research, to prevent the adoption of “easy solutions” that
could lead to products that do not live up to expectations. The use
of LEDs requires in-depth calculations to determine the appropria-
te power supply and heat dissipation, an accurate souring of raw
materials and new concept studies to calculate lighting require-
ments that are suitable for the new light source.
Only continual research into total quality can create products that
are suitable for new technological developments, combining
performance, design and energy saving.
Thermo-fluid dynamics analysis:
calculated heat dissipation
To guarantee a long-lasting, high performance LED source, a new
technology has been adopted which simulates heat diffusion in
the fixture: Thermo-fluid dynamics analysis can predict the opera-
ting temperature of various components, in order to optimise the
heat dissipation system.
Light Emitting Diodes, an ecological choice
Continual advances in technology have led to the development of
the LED light sources over the last few years, which among other
things, allows for outstanding energy savings, and up to 70%
more than that achieved with other light sources. Besides energy
saving and a reduction in CO2, as a result of the reduced con-
sumption of fixtures, LED sources, if powered adequately, increa-
se the life of a light source tenfold, thus reducing volumes of
waste to dispose of or recycle.
SMD electronic circuit integrated in the lamp housing
The sophisticated electronics for Beghelli LED fixtures have been
developed using SMD miniature technology. This technology
allows the overall dimensions of equipment to be reduced and
considerably improves reliability.
Integrated control system: AT, LG, LGFM
All fixtures in the new Stella Polare LED Beghelli range have
systems to guarantee the testing which must be carried out by
the protection and prevention service manager, as required by
UNI 11222.
The control system can be self-powered in the minimum configu-
ration, with signalling LEDs (AT), self-powered and centralised
(LG, LG-FM).
125
The precision of a light beam
With a precision light source,
such as a LED, light rays can be
intercepted, using specially sha-
ped lenses to direct the light
beam with the utmost precision.
(the Largaluce lens
in the example)
Uniform illumination
A precise source enables the use of lenses with particularly effi-
cient shapes and this also optimises light diffusion, in terms of pic-
togram uniformity and intensity.
Plus the opaline, polycarbonate screens used for the
Stella Polare LED range mean that signs do not have to be stuck
onto the units, which produces less attractive results and less effi-
cient sign luminosity.
40” 60” 20” 50” 30” 10”
light
flow
time
Fixture with LED source
Fixture
with
fluorescent
tube
0
50
100
150
200
250
300
350
400
Instant operation for maximum safety
During black outs, the first seconds are often the most critical: the
LED system of Beghelli fixtures instantly guarantees nominal light,
unlike fluorescent lamps that take a minute to reach nominal light
after being turned on.
LED sources, to respect the environment
Beghelli's design choices aim to reduce materials used and energy
consumption, as well as the need for end-of-life disposal.
The use of long-life LED sources is in line with the WEEE Directive
for the environmentally friendly disposal of technological compo-
nents.
Illuminated area:196 m 2 at 0,5 lx
h 3m
TEC
HN
ICA
L
ATTA
CH
MEN
T
126
Quick, accurate
installation
IP PLUG Beghelli (IP66) cable glands membrane
Beghelli's concept of modern technology embodies simple instal-
lation combined with precision connections. The wiring of new-
generation emergency luminaires must be immediate, and also
guarantee IP ratings. In the case of the IP PLUG, the IP rating is
maintained at IP66. For this reason, all fixtures in the new Stella
Polare LED Beghelli range have multiple configurations for cable
input, which can each house an IP Lock membrane - a special
elastic lip cable glands that can house multi-pole�cables�up�to
13�mm�in�diameter.
"Invisible" connection adapter (IP66)
Quick installation operations must not forego the concept of a sty-
lish system.
The fixtures in the new Stella Polare LED Beghelli range embody
a new design concept for emergency lighting. They feature sim-
ple yet sleek lines, which are not common to normal mechanical
wiring systems.
The "invisible" adapter makes it possible to fit tubular raceways
and spiral sheathing with a diameter of 16 and 20, with a quick-fit
self-locking system that reduces the overall dimensions of the
installed fixture, speeds up installation, and when required, gua-
rantees an IP rating of IP66.
127
Integrated bubble level for quick wall mounting
With their focus on installation and ergonomics, products in the
Stella Polare LED Beghelli range have been designed to make
every part of installation even easier: to make it quicker to position
the housing during fixing, a bubble level has been incorporated to
show the fixture's horizontal position.
Recessed box provided
The look of the recessed version is often more attractive than the
ceiling version. The thickness of the visible part gives the fixture a
leaner profile. In some cases the recessed box is also supplied
with a wire cover, to complete installation.
Configured for installation with main
connector boxes of civil lighting systems
The housing of Stella Polare LED Beghelli fixtures has internal
tracking, for fixing on main European and American standard con-
nector boxes. This is particularly useful for installation in existing
systems, where masonry works or unattractive additional
raceways are not appropriate.
Excellent light diffusion
polycarbonate screens
The Stella Polare LED Beghelli sign systems have screen-printed,
shockproof polycarbonate screens. These means that the fitter
does not have to stick on adhesives and saves time and avoids
unattractive results. Plus the quality of the screens and relative
optical back lighting systems ensure the most uniform luminosity
possible for the safety sign, also in terms of visibility and contrast,
as required by UNI1838.
TEC
HN
ICA
L
ATTA
CH
MEN
T
128
C0-C180 C90-C270
cd/klm
600
800
400
Acciaio LED
24 W
30° 15° 0° 15° 30°
105°
90°
75°
60°
45°
105°
90°
75°
60°
45°
C0-C180 C90-C270
cd/klm
Logica LED6-8-11-24 W
100
150
200
250
0° 15° 30° 45°
60°
75°
90°
105°
120°
135°150°165°180°165°150°135°
120°
105°
90°
75°
60°
45° 30° 15° 0°
C0-C180 C90-C270
cd/klm
CREATIVA LED
6-8-11-24 W
300
400
200
105°
90°
75°
60°
45°
105°
90°
75°
60°
45°
30° 15° 0° 15° 30°
Photometric diagrams
and Luce Utile
2,20 5x3,5 2,48 8,5x5 - - 0,58 9,5x5
3,09 6x4 3,47 9,5x6 - - 0,82 12,5x7
lx m lx m lx m lx m
824
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
5,32 7x4 3,49 11x5 - - 0,72 14x8
6,64 7,5x4,5 4,36 12x6 1 13x3 0,90 15x8
7,97 8x5 5,24 13x6 1,2 15x4 1,09 15x9
lx m lx m lx m lx m
81124
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
The figure in lux refers to the illuminance value at ground level whi-
ch the fixture can reach, with an established installation height.
The figure in metres corresponds instead to the surface area (side
x side) which the fixture illuminates with the minimum value indi-
cated in EN 1838.
By combining the two data, elements are provided for the imme-
diate evaluation of the lighting characteristics of an emergency
luminaire.
Symbols and description of the Luce Utile project page 140
Acciaio LED
Logica LEDCreativa LED
129
C0-C180 C90-C270
cd/klm
FORMULA 65 LED
6-8-11-24 W
240
320
160
105°
90°
75°
60°
45°
105°
90°
75°
60°
45°
30° 15° 0° 15° 30°
C0-C180 C90-C270
cd/klm
DESIGN TECH LED
6-8-11-24 W
300
400
200
105°
90°
75°
60°
45°
105°
90°
75°
60°
45°
30° 15° 0° 15° 30°
C0-C180 C90-C270
GRANLUCE LED
6-11 W
cd/klm
1600
2400
3200
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
C0-C180 C90-C270
GRANLUCE LED
8-18-24 W
cd/klm
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
3000
1500
1000
2000
2500
2,64 5,5x12 - - - - - -
4,61 6,5x12,5 1,08 5,5x1,5 - - - -
5,77 7,5x13 1,35 7x2 - - - -
lx m lx m lx m lx m
81824
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
- - 1,08 - - - - -
1,42 - 1,70 5,5x4 - - . -
1,55 - 1,86 6x4,5 - - 0,50 -
2,90 6x4 3,48 8x6 1,00 - 0,88 8x10
lx m lx m lx m lx m
681124
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
- - 1,08 - - - - -
1,11 - 1,80 5,5x4 - - - -
1,34 - 2,16 6x4,5 - - - -
2,12 6x4 3,42 8x6 - - 0,88 8x10
lx m lx m lx m lx m
681124
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
2,19 5x12 - - - - - -
3,19 5,5x2,5 1,20 - - - . -
lx m lx m lx m lx m
611
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 6 m
Formula 65 LED
Granluce LED
Design Tech LED
Granluce LED
PH
OTO
METR
IC D
IAG
RA
MS
AN
D L
UC
E U
TIL
E
130
C0-C180 C90-C270
LED MODULELungaluce lens
cd/klm
1000
1500
2000
2500
3000
0° 15° 30° 45°
60°
75°
90°
105°
120°
135°150°165°180°165°150°135°
120°
105°
90°
75°
60°
45° 30° 15° 0°
C0-C180 C90-C270
LED MODULE Largaluce lens
cd/klm
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
C0-C180 C90-C270
LED MODULE
Altaluce lens
cd/klm
300
400
500
600
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
- - 2,44 16,5x2 - - - -
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 3 m
- - - - 0,70 12x12 - -
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 3 m
- - - - - - 0,94 12x12
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 3 m
LED ModuleLED Module
LED Module
131
C0-C180 C90-C270
LUNGALUCE LEDlente Lungaluce
cd/klm
1000
1500
2000
2500
3000
0° 15° 30° 45°
60°
75°
90°
105°
120°
135°150°165°180°165°150°135°
120°
105°
90°
75°
60°
45° 30° 15° 0°
C0-C180 C90-C270
LUNGALUCE LEDLargaluce lens
cd/klm
320
480
640
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
C0-C180 C90-C270
LUNGALUCE LED
Diffusaluce lens
cd/klm
150
100
200
250
300
0° 15° 30°
45°
60°
75°
90°
105°105°
90°
75°
60°
45°
30° 15° 0°
- - 2,44 16,5x2 - - - -
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
RECESSED / CEILING VERSION
H 2,5 m H 3 m H 6 m H 3 m
- - - - - - 0,94 12x12
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 3 m
WALL VERSION
RECESSED / CEILING VERSION
1,16 - - - - - - -
lx m lx m lx m lx m
24
Luce Utile: illuminance value (Lux) and illuminated surface (m)
W
H 2,5 m H 3 m H 6 m H 3 m
Lungalargaluce LED
Lungalargaluce LED
Lungalargaluce LED
PH
OTO
METR
IC D
IAG
RA
MS
AN
D L
UC
E U
TIL
E
132
Analytical
index
Fixtures
sorted by code 136
sorted by power 137
sorted by system 138
Accessories
sorted by code 139
Spare parts
batteries 139
133
134
3310 Illumina LED bianca 112
3311 Illumina LED Ricarica nera 112
4270 DESIGN LED TECH AT 6W SE 1H 42
4271 DESIGN LED TECH AT 8W SE 1H 42
4272 DESIGN LED TECH AT 11W SE 1H 42
4273 DESIGN LED TECH AT 11W SA 1H 42
4274 DESIGN LED TECH AT 24W SE 1H 42
4275 DESIGN TECH LED BANDIERA AT 11W SA 1H DX/SX 42
4276 DESIGN TECH LED BANDIERA AT 11W SA 1H BASSO 42
4279 DESIGN TECH LED AT 8W SE/SA 3N 42
4280 DESIGN TECH LED AT 24W SE/SA 3N 42
4601 FRUTTOLUCE1 LED SE/SA 1N 48
4602 FRUTTOLUCE2 LED SE/SA 1N 54
4603 FRUTTOLUCE3 LED SE/SA 1N 60
4605 FRUTTOLUCE6 LED 4605-SE/SA 1N 66
12182 LOGICA LED LG 8W SE 1/2/3H 16
12182FM LOGICA LED LGFM 8W SE 1/2/3H 17
12183 LOGICA LED LG 11W SE 1/2/3H 16
12183FM LOGICA LED LGFM 11W SE 1/2/3H 17
12184 LOGICA LED LG 24W SE 1/2/3H 16
12184FM LOGICA LED LGFM 24W SE 1/2/3H 17
12185 LOGICA LED LG 8W SA/PS 1/2/3H 16
12185FM LOGICA LED LGFM 8W SA/PS 1/2/3H 17
12186 LOGICA LED LG 11W SA/PS 1/2/3H 16
12186FM LOGICA LED LGFM 11W SA/PS 1/2/3H 17
12187 LOGICA LED LG 24W SA/PS 1/2/3H 16
12187FM LOGICA LED LGFM 24W SA/PS 1/2/3H 17
12950 GRANLUCE LED IP65 AT 6W SE1NRM 72
12951 GRANLUCE LED IP65 AT 6W SE3NRM 72
12952 GRANLUCE LED IP65 AT 8W SE1NRM 76
12953 GRANLUCE LED IP65 AT 8W SE3NRM 76
12954 GRANLUCE LED IP65 AT 8W SA1NRM 76
12955 GRANLUCE LED IP65 AT 8W SA3NRM 76
12956 GRANLUCE LED IP65 AT 11WSE1NRM 72
12957 GRANLUCE LED IP65 AT 11WSE3NRM 72
12960 GRANLUCE LED IP65 AT 18WSE1NRM 76
12961 GRANLUCE LED IP65 AT 18WSE3NRM 76
12962 GRANLUCE LED IP65 AT 18WSA1NRM 76
12963 GRANLUCE LED IP65 AT 18WSA3NRM 76
12964 GRANLUCE LED IP65 AT 24WSE1NRM 76
12965 GRANLUCE LED IP65 AT 24WSE3NRM 76
12966 GRANLUCE LED IP65 AT 24WSA1NRM 76
12967 GRANLUCE LED IP65 AT 24WSA3NRM 76
15000 ACCIAIO LED 8W SE AT 1H 10
15001 ACCIAIO LED 8W SA AT 1H 10
15002 ACCIAIO LED 24W SE AT 1H 10
15003 ACCIAIO LED 24W SA AT 1H 10
15004 ACCIAIO LED 8W SE/SA/PS LG 2/3/6H 10
15005 ACCIAIO LED 8W SE/SA/PS LGFM 2/3/6H 10
15006 ACCIAIO LED 24W SE/SA/PS LG 1/2/3H 10
15007 ACCIAIO LED 24W SE/SA/PS LGFM 1/2/3H 11
15008 ACC LED 24W SE/SA AT 1/3N 10
17403 LOGICA LED HT 8W 17
17404 LOGICA LED HT 11W 17
17405 LOGICA LED HT 24W 17
17422 GRANLUCE 2LED HT IP65 77
17450 ACCIAIO LED 8W HT IP66 11
17451 ACCIAIO LED 24W HT IP66 11
19220 FORMULA65 LED 6W IP65 AT SE 1H/RM 36
19221 FORMULA65 LED 6W IP65 AT SE 3H/RM 36
19222 FORMULA65 LED 8W IP65 AT SE 1H/RM 36
19223 FORMULA65 LED 8W IP65 AT SE 3H/RM 36
19224 FORMULA65 LED 8W IP65 AT SA 1H/RM 36
19225 FORMULA65 LED 8W IP65 AT SA 3H/RM 36
19226 FORMULA65 LED 11W IP65 AT SE 1H/RM 36
19227 FORMULA65 LED 11W IP65 AT SE 3H/RM 36
19228 FORMULA65 LED 11W IP65 AT SA 1H/RM 36
19229 FORMULA65 LED 11W IP65 AT SA 3H/RM 36
19230 FORMULA65 LED 24W IP65 AT SE 1H/RM 36
19231 FORMULA65 LED 24W IP65 AT SE 3H/RM 36
19232 FORMULA65 LED 24W IP65 AT SA 1H/RM 36
19233 FORMULA65 LED 24W IP65 AT SA 3H/RM 36
19300 INDICA LED DF30M HT 105
19301 INDICA LED DF20M HT 97
19304 INDICA LED DF30M LG SA/PS 1/2/3H 105
19305 INDICA LED DF20M LG SA/PS 1/2/3H 97
19306 INDICA LED DF30M LGFM SA/PS 1/2/3H 105
19307 INDICA LED DF20M LGFM SA/PS 1/2/3H 97
19308 IND LED DF30M AT SA/PS 1/3H 105
19309 IND LED DF20M AT SA/PS 1/3H 97
19310 INDICA LED SF30M HT 106
19311 INDICA LED SF20M HT 98
19314 INDICA LED SF30M LG SAPS 1/2/3H 106
19315 INDICA LED SF20M LG SAPS 1/2/3H 98
19316 INDICA LED SF30M LGFM SAPS 1/2/3H 106
19317 INDICA LED SF20M LGFM SAPS 1/2/3H 98
19318 IND LED SF30M AT SA/PS 1/3H 106
19319 IND LED SF20M AT SA/PS 1/3H 98
19320 LUNGALARGALUCE LED DW CL HT 24W 28
19322 LUNGALARGALUCE LED DW CL LG 24W SE/SA/PS 1/2/3H 28
19323 LUNGALARGALUCE LED DW CL LGFM24W SE/SA/PS 1/2/3H 28
19324 L.LARGA DWCL SY AT SE/SA 1/3H 28
19325 L.LARGA DWCL ASY AT SE/SA 1/3H 28
19330 LUNGALARGALUCE LED DW RC HT 24W 22
19332 LUNGALARGALUCE LED DW RC LG 24W SE/SA/PS 1/2/3H 22
19333 LUNGALARGALUCE LED DW RC LGFM 24W SE/SA/PS 1/2/3H 22
19334 L.LARGA DWRC SY AT SE/SA 1/3N 22
19335 L.LARGA DWRC ASY AT SE/SA 1/3N 22
19340 MODULO EMERGENZA LED HT 89
19342 MODULO EMERGENZA LED LG SE/SA/PS 1/2/3H 88
19343 MODULO EMERGENZA LED LGFM SE/SA/PS 1/2/3H 88
19344 MODULE EM LED AT SE/SA 1/3H 88
19401 CREATIVA LED 8W AT SE/SA 1/3H 82
19402 CREATIVA LED 11W AT SE/SA 1/3H 82
19403 CREATIVA LED 24W AT SE/SA 1/3H 82
Code Article page Code Article page
Fixtures sorted by code
135
Fixtures sorted by power
0,5 3310 Illumina LED bianca 112
0,5 4602 FRUTTOLUCE2 LED SE/SA 1N 54
0,5 4603 FRUTTOLUCE3 LED SE/SA 1N 60
0,5 4601 FRUTTOLUCE1 LED SE/SA 1N 48
2 x 0,5 4605 FRUTTOLUCE6 LED 4605-SE/SA 1N 66
1,6 3311 Illumina LED Ricarica nera 112
2,1 19301 INDICA LED DF20M HT 97
2,1 19305 INDICA LED DF20M LG SA/PS 1/2/3H 97
2,1 19307 INDICA LED DF20M LGFM SA/PS 1/2/3H 97
3,2 19300 INDICA LED DF30M HT 105
3,2 19304 INDICA LED DF30M LG SA/PS 1/2/3H 105
3,2 19306 INDICA LED DF30M LGFM SA/PS 1/2/3H 105
3,6 17422 GRANLUCE 2LED HT IP65 77
6 4270 DESIGN LED TECH AT 6W SE 1H 42
6 19220 FORMULA65 LED 6W IP65 AT SE 1H/RM 36
6 19221 FORMULA65 LED 6W IP65 AT SE 3H/RM 36
6 12950 GRANLUCE LED IP65 AT 6W SE1NRM 72
6 12951 GRANLUCE LED IP65 AT 6W SE3NRM 72
8 4271 DESIGN LED TECH AT 8W SE 1H 42
8 4279 DESIGN LED TECH AT 8W SE/SA 3N 42
8 12182 LOGICA LED LG 8W SE 1/2/3H 16
8 12185 LOGICA LED LG 8W SA/PS 1/2/3H 16
8 17403 LOGICA LED HT 8 17
8 19222 FORMULA65 LED 8W IP65 AT SE 1H/RM 36
8 19223 FORMULA65 LED 8W IP65 AT SE 3H/RM 36
8 19224 FORMULA65 LED 8W IP65 AT SA 1H/RM 36
8 19225 FORMULA65 LED 8W IP65 AT SA 3H/RM 36
8 19401 CREATIVA LED 8W AT SE/SA 1/3H 82
8 12182FM LOGICA LED LGFM 8W SE 1/2/3H 17
8 12185FM LOGICA LED LGFM 8W SA/PS 1/2/3H 17
8 12952 GRANLUCE LED IP65 AT 8W SE1NRM 76
8 12953 GRANLUCE LED IP65 AT 8W SE3NRM 76
8 12954 GRANLUCE LED IP65 AT 8W SA1NRM 76
8 12955 GRANLUCE LED IP65 AT 8W SA3NRM 76
8 15000 ACCIAIO LED 8W SE AT 1H 10
8 15001 ACCIAIO LED 8W SA AT 1H 10
8 15004 ACCIAIO LED 8W SE/SA/PS LG 2/3/6H 10
8 15005 ACCIAIO LED 8W SE/SA/PS LGFM 2/3/6H 10
8 17450 ACCIAIO LED 8W HT IP66 11
11 4272 DESIGN LED TECH AT 11W SE 1H 42
11 4273 DESIGN LED TECH AT 11W SA 1H 42
11 4275 DESIGN TECH LED BANDIERA AT 11W SA 1H DX/SX 42
11 4276 DESIGN TECH LED BANDIERA AT 11W SA 1H BASSO 42
11 12183 LOGICA LED LG 11W SE 1/2/3H 16
11 12186 LOGICA LED LG 11W SA/PS 1/2/3H 16
11 17404 LOGICA LED HT 11 17
11 19226 FORMULA65 LED 11W IP65 AT SE 1H/RM 36
11 19227 FORMULA65 LED 11W IP65 AT SE 3H/RM 36
11 19228 FORMULA65 LED 11W IP65 AT SA 1H/RM 36
11 19229 FORMULA65 LED 11W IP65 AT SA 3H/RM 36
11 19402 CREATIVA LED 11W AT SE/SA 1/3H 82
11 12183FM LOGICA LED LGFM 11W SE 1/2/3H 17
11 12186FM LOGICA LED LGFM 11W SA/PS 1/2/3H 17
11 12956 GRANLUCE LED IP65 AT 11WSE1NRM 72
11 12957 GRANLUCE LED IP65 AT 11WSE3NRM 72
18 12960 GRANLUCE LED IP65 AT 18WSE1NRM 76
18 12961 GRANLUCE LED IP65 AT 18WSE3NRM 76
18 12962 GRANLUCE LED IP65 AT 18WSA1NRM 76
18 12963 GRANLUCE LED IP65 AT 18WSA3NRM 76
24 4274 DESIGN LED TECH AT 24W SE 1H 42
24 4280 DESIGN LED TECH AT 24W SE/SA 3N 42
24 12184 LOGICA LED LG 24W SE 1/2/3H 16
24 12187 LOGICA LED LG 24W SA/PS 1/2/3H 16
24 17405 LOGICA LED HT 24 17
24 19230 FORMULA65 LED 24W IP65 AT SE 1H/RM 36
24 19231 FORMULA65 LED 24W IP65 AT SE 3H/RM 36
24 19232 FORMULA65 LED 24W IP65 AT SA 1H/RM 36
24 19233 FORMULA65 LED 24W IP65 AT SA 3H/RM 36
24 19320 LUNGALARGALUCE LED DW CL HT 24 28
24 19322LUNGALARGALUCE LED DW CL LG 24W SE/SA/PS 1/2/3H 28
24 19323LUNGALARGALUCE LED DW CL LGFM24W SE/SA/PS 1/2/3H 28
24 19330 LUNGALARGALUCE LED DW RC HT 24 22
24 19332LUNGALARGALUCE LED DW RC LG 24W SE/SA/PS 1/2/3H 22
24 19333LUNGALARGALUCE LED DW RC LGFM 24W SE/SA/PS 1/2/3H 22
24 19403 CREATIVA LED 24W AT SE/SA 1/3H 82
24 12184FM LOGICA LED LGFM 24W SE 1/2/3H 17
24 12187FM LOGICA LED LGFM 24W SA/PS 1/2/3H 17
24 12964 GRANLUCE LED IP65 AT 24WSE1NRM 76
24 12965 GRANLUCE LED IP65 AT 24WSE3NRM 76
24 12966 GRANLUCE LED IP65 AT 24WSA1NRM 76
24 12967 GRANLUCE LED IP65 AT 24WSA3NRM 76
24 15002 ACCIAIO LED 24W SE AT 1H 10
24 15003 ACCIAIO LED 24W SA AT 1H 10
24 15006 ACCIAIO LED 24W SE/SA/PS LG 1/2/3H 10
24 15007 ACCIAIO LED 24W SE/SA/PS LGFM 1/2/3H 11
24 15008 ACC LED 24W SE/SA AT 1/3N 10
24 17451 ACCIAIO LED 24W HT IP66 11
18÷58 19340 MODULO EMERGENZA LED HT 89
18÷58 19342 MODULO EMERGENZA LED LG SE/SA/PS 1/2/3H 88
18÷58 19343 MODULO EMERGENZA LED LGFM SE/SA/PS 1/2/3H 88
18÷58 19344 MODULE EM LED AT SE/SA 1/3H 88
Segnaletica 19308 IND LED DF30M AT SA/PS 1/3H 105
Segnaletica 19309 INDICA LED DF20M AT SA 1/H 97
Segnaletica 19311 INDICA LED SF20M HT 98
Segnaletica 19315 INDICA LED SF20M LG SAPS 1/2/3H 98
Segnaletica 19317 INDICA LED SF20M LGFM SAPS 1/2/3H 98
Segnaletica 19318 INDICA LED SF30M AT SA 1N 106
Segnaletica 19319 INDICA LED SF20M AT SA 1N 98
Segnaletica 19310 INDICA LED SF30M HT 106
Segnaletica 19314 INDICA LED SF30M LG SAPS 1/2/3H 106
Segnaletica 19316 INDICA LED SF30M LGFM SAPS 1/2/3H 106
Power W * Code Article page Power W * Code Article page
* Indicative power for comparison with fluorescent tube lighting
136
AT 4270 DESIGN LED TECH AT 6W SE 1H 42
AT 4271 DESIGN LED TECH AT 8W SE 1H 42
AT 4272 DESIGN LED TECH AT 11W SE 1H 42
AT 4273 DESIGN LED TECH AT 11W SA 1H 42
AT 4274 DESIGN LED TECH AT 24W SE 1H 42
AT 4275 DESIGN TECH LED BANDIERA AT 11W SA 1H DX/SX 42
AT 4276 DESIGN TECH LED BANDIERA AT 11W SA 1H BASSO 42
AT 4279 DESIGN TECH LED AT 8W SE/SA 3N 42
AT 4280 DESIGN LED TECH AT 24W SE/SA 3N 42
AT 19220 FORMULA65 LED 6W IP65 AT SE 1H/RM 36
AT 19221 FORMULA65 LED 6W IP65 AT SE 3H/RM 36
AT 19222 FORMULA65 LED 8W IP65 AT SE 1H/RM 36
AT 19223 FORMULA65 LED 8W IP65 AT SE 3H/RM 36
AT 19224 FORMULA65 LED 8W IP65 AT SA 1H/RM 36
AT 19225 FORMULA65 LED 8W IP65 AT SA 3H/RM 36
AT 19226 FORMULA65 LED 11W IP65 AT SE 1H/RM 36
AT 19227 FORMULA65 LED 11W IP65 AT SE 3H/RM 36
AT 19228 FORMULA65 LED 11W IP65 AT SA 1H/RM 36
AT 19229 FORMULA65 LED 11W IP65 AT SA 3H/RM 36
AT 19230 FORMULA65 LED 24W IP65 AT SE 1H/RM 36
AT 19231 FORMULA65 LED 24W IP65 AT SE 3H/RM 36
AT 19232 FORMULA65 LED 24W IP65 AT SA 1H/RM 36
AT 19233 FORMULA65 LED 24W IP65 AT SA 3H/RM 36
AT 19401 CREATIVA LED 8W AT SE/SA 1/3H 82
AT 19402 CREATIVA LED 11W AT SE/SA 1/3H 82
AT 19403 CREATIVA LED 24W AT SE/SA 1/3H 82
AT 12950 GRANLUCE LED IP65 AT 6W SE1NRM 72
AT 12951 GRANLUCE LED IP65 AT 6W SE3NRM 72
AT 12952 GRANLUCE LED IP65 AT 8W SE1NRM 76
AT 12953 GRANLUCE LED IP65 AT 8W SE3NRM 76
AT 12954 GRANLUCE LED IP65 AT 8W SA1NRM 76
AT 12955 GRANLUCE LED IP65 AT 8W SA3NRM 76
AT 12956 GRANLUCE LED IP65 AT 11WSE1NRM 72
AT 12957 GRANLUCE LED IP65 AT 11WSE3NRM 72
AT 12960 GRANLUCE LED IP65 AT 18WSE1NRM 76
AT 12961 GRANLUCE LED IP65 AT 18WSE3NRM 76
AT 12962 GRANLUCE LED IP65 AT 18WSA1NRM 76
AT 12963 GRANLUCE LED IP65 AT 18WSA3NRM 76
AT 12964 GRANLUCE LED IP65 AT 24WSE1NRM 76
AT 12965 GRANLUCE LED IP65 AT 24WSE3NRM 76
AT 12966 GRANLUCE LED IP65 AT 24WSA1NRM 76
AT 12967 GRANLUCE LED IP65 AT 24WSA3NRM 76
AT 15000 ACCIAIO LED 8W SE AT 1H 10
AT 15001 ACCIAIO LED 8W SA AT 1H 10
AT 15002 ACCIAIO LED 24W SE AT 1H 10
AT 15003 ACCIAIO LED 24W SA AT 1H 10
AT 15008 ACC LED 24W SE/SA AT 1/3N 10
AT 19308 IND LED DF20M AT SA/PS 1/3H 105
AT 19309 IND LED DF20M AT SA/PS 1/3H 97
AT 19318 IND LED SF30M AT SA/PS 1/3H 106
AT 19319 IND LED SF20M AT SA/PS 1/3H 98
AT 19324 L.LARGA DWCL SY AT SE/SA 1/3H 28
AT 19325 L.LARGA DWCL ASY AT SE/SA 1/3H 28
AT 19334 L.LARGA DWRC SY AT SE/SA 1/3N 22
AT 19335 L.LARGA DWRC ASY AT SE/SA 1/3N 22
AT 19344 MODULE EM LED AT SE/SA 1/3H 88
LG 12182 LOGICA LED LG 8W SE 1/2/3H 16
LG 12183 LOGICA LED LG 11W SE 1/2/3H 16
LG 12184 LOGICA LED LG 24W SE 1/2/3H 16
LG 12185 LOGICA LED LG 8W SA/PS 1/2/3H 16
LG 12186 LOGICA LED LG 11W SA/PS 1/2/3H 16
LG 12187 LOGICA LED LG 24W SA/PS 1/2/3H 16
LG 19304 INDICA LED DF30M LG SA/PS 1/2/3H 105
LG 19305 INDICA LED DF20M LG SA/PS 1/2/3H 97
LG 19314 INDICA LED SF30M LG SAPS 1/2/3H 106
LG 19315 INDICA LED SF20M LG SAPS 1/2/3H 98
LG 19322 LUNGALARGALUCE LED DW CL LG 24W SE/SA/PS 1/2/3H 28
LG 19332 LUNGALARGALUCE LED DW RC LG 24W SE/SA/PS 1/2/3H 22
LG 19342 MODULO EMERGENZA LED LG SE/SA/PS 1/2/3H 88
LG 15004 ACCIAIO LED 8W SE/SA/PS LG 2/3/6H 10
LG 15006 ACCIAIO LED 24W SE/SA/PS LG 1/2/3H 10
LGFM 19306 INDICA LED DF30M LGFM SA/PS 1/2/3H 105
LGFM 19307 INDICA LED DF20M LGFM SA/PS 1/2/3H 97
LGFM 19316 INDICA LED SF30M LGFM SAPS 1/2/3H 106
LGFM 19317 INDICA LED SF20M LGFM SAPS 1/2/3H 98
LGFM 19323 LUNGALARGALUCE LED DW CL LGFM24W SE/SA/PS 1/2/3H 28
LGFM 19333 LUNGALARGALUCE LED DW RC LGFM 24W SE/SA/PS 1/2/3H 22
LGFM 19343 MODULO EMERGENZA LED LGFM SE/SA/PS 1/2/3H 88
LGFM 12182FM LOGICA LED LGFM 8W SE 1/2/3H 17
LGFM 12183FM LOGICA LED LGFM 11W SE 1/2/3H 17
LGFM 12184FM LOGICA LED LGFM 24W SE 1/2/3H 17
LGFM 12185FM LOGICA LED LGFM 8W SA/PS 1/2/3H 17
LGFM 12186FM LOGICA LED LGFM 11W SA/PS 1/2/3H 17
LGFM 12187FM LOGICA LED LGFM 24W SA/PS 1/2/3H 17
LGFM 15005 ACCIAIO LED 8W SE/SA/PS LGFM 2/3/6H 10
LGFM 15007 ACCIAIO LED 24W SE/SA/PS LGFM 1/2/3H 10
HT 17403 LOGICA LED HT 8W 17
HT 17404 LOGICA LED HT 11W 17
HT 17405 LOGICA LED HT 24W 17
HT 19300 INDICA LED DF30M HT 105
HT 19301 INDICA LED DF20M HT 97
HT 19310 INDICA LED SF30M HT 106
HT 19311 INDICA LED SF20M HT 98
HT 19320 LUNGALARGALUCE LED DW CL HT 24W 28
HT 19330 LUNGALARGALUCE LED DW RC HT 24W 22
HT 19340 MODULO EMERGENZA LED HT 89
HT 17422 GRANLUCE 2LED HT IP65 77
HT 17450 ACCIAIO LED 8W HT IP66 11
HT 17451 ACCIAIO LED 24W HT IP66 11
Tradizionale 3310 Illumina LED bianca 112
Tradizionale 3311 Illumina LED Ricarica nera 112
Tradizionale 4602 FRUTTOLUCE2 LED SE/SA 1N 54
Tradizionale 4603 FRUTTOLUCE3 LED SE/SA 1N 60
Tradizionale 4605 FRUTTOLUCE6 LED 4605-SE/SA 1N 66
Tradizionale 4601 FRUTTOLUCE1 LED SE/SA 1N 48
System Code Article page System Code Article page
Fixtures sorted by system
137
4258 415347001
4259 415347001
4260 415347001
4261 415347001
4262 415347001
4270 415347001
4271 415347001
4272 415347001
4273 415347001
4274 415347001
4275 415347001
4276 415347001
4279
4280
14810 415389000
14811 415389000
14812 415389000
14813 415389000
14814 415389000
14815 415389000
15000 415386001
15001 415386001
15002 415386001
15003 415386001
15004 415386001
15005 415386001
15006 415386001
15007 415386001
15008
16732 415386001
16733 415386001
16734 415386001
16735 415386001
16736 415386001
16737 415386001
16748 415386001
16749 415386001
16750 415386001
16751 415386001
16752 415386001
16753 415386001
19200 415347001
19201 415354003
19202 415347001
19203 415354003
19204 415347001
19205 415354003
19206 415347001
19207 415354003
19208 415347001
19210 415347001
19211 415354003
19212 415347001
19220 415347001
19221 415354003
19222 415347001
19223 415354003
19225 415354003
19226 415347001
19227 415354003
19228 415347001
19229 415354003
19230 415347001
19231 415354003
19233 415354003
19304 415389000
19305 415389000
19306 415389000
19307 415389000
19308 415390000
19309 415390000
19314 415386001
19315 415386001
19316 415386001
19317 415386001
19318 415386001
19319 415386001
19322 415386001
19323 415386001
19324 415391001
19325 415391001
19332 415386001
19333 415386001
19334 415391001
19335 415391001
19342 415386001
19343 415386001
19344 415391001
19401 415225002
19402 415225002
19403 415225002
Code product Code battery Code product Code battery Code product Code battery
Spare parts batteries
- Pressatubo Formula 65 36
3727 pressatubo PG16/PG20 4003/RG 76
3733 scatola da incasso 42
4266 STAFFA CONTROSOFFITTO DESIGN 42
4277 STAFFA PARETE X BANDIERA DESIGN 42
4278 ADES 3 SX DX BS DESIGN LED TECH 42
4620 scatola da incasso 6 frutti 66
4621 placca di copertura standard 66
4623 placca IP55 antivandalica 66
12175 screen Logica DS 16
12176 screen Logica SN 16
12177 screen Logica BASSO 16
12193 staffa controsoffitto Logica 16
12194 griglia lampada logica 16
12198 Scatola da incasso con cornice coprifilo 16
12199 Staffa di fissaggio rapido a parete 16
12941 etichette segnaletiche 8,18,24 W 76
12942 Kit incasso 6,11 W 72
12943 Kit incasso 8,18,24 W 76
15009 SCREEN DX/SX/BASSO ACCIAIO EM 10
15010 SCREEN BANDIERA DX/SX ACCIAIO EM 10
15011 SCREEN BANDIERA BASSO ACCIAIO EM 10
15012 STAFFA CONTROS/INCASSO ACCIAIO EM 10
15016 STAFFA A PARETE PER BANDIERA ACCIAIO EM 10
15017 KIT ATEX 10
19040 Scatola da incasso + cornici F65 36
19041 STAFFA CONTROSOFFITTO F65 36
19042 SCREEN BANDIERA DX/SX F65 36
19043 SCREEN BANDIERA BASSO F65 36
19044 ADES SX DX BS F65 36
19045 STAFFA A PARETE PER BANDIERA F65 36
19380 TIGES 250MM INDICA DF 104
19381 TIGES 500MM INDICA DF 104
19382 TIGES 1000MM INDICA DF 104
19383 SOSPENSIONE A CAVO 2MT INDICA DF 104
Code Article page Code Article page
Accessories
138
H 6 m
5 m
6 m
5 m
Ceiling assembly, large areasThe area in which the portion of illuminance which can be used in safety lighting for large areas
as emergency lighting, is calculated as an area of an indefinite width and length, 6.5 metres
high, with products installed at a height of 6 metres. The area in which useful lighting is
defined is 25 m2 below the product. The configuration chosen is attributable to most
installations in large areas. The calculations refer to the ground and do not account for
reflections, with a maintenance factor of 0.8.
EN 1838: minimum 0.5 lx of the entire area.
H 3 m
5 m
3 m
5 m
Ceiling assembly, large areasThe area in which the portion of illuminance which can be used in safety lighting for large areas
as emergency lighting, is calculated as an area of an indefinite width and length, 3 metres high,
with products installed at a height of 3 metres. The area in which useful lighting is defined is 25
m2 below the product. The calculations refer to the ground and do not account for reflections,
with a maintenance factor of 0.8.
EN 1838: minimum 0.5 lx of the entire area.
Useful light fixtures, based on Beghelli standards, deliver specific illuminance (Lx) on the ground, if installed at the distance
indicated in the Luce Utile project, and indicated alongside the icon which specifies the direction and amplitude of the light beam.
The definition of the lighting characteristics of a fixture may be simplified, using the only item of data useful for design purposes:ground illuminance expressed in Lux. To ensure this data, some typical installation situations need to be sized, cataloguing each
product not on light flow, but on the basis of various lighting data in different conditions of use for which the fixture is intended.
This data is available for some products only, in the technical attachment on page 136
H 6 m
H 3 m
H 2,5 m
3 m
2 m1 m
5 m
2,5 m
Wall mounting of escape routesConfiguration chosen: Undefined corridor length, width 2m, height 3m. Installation height
2.5m. Horizontal WALL mounting. The area in which the portion of illuminance can be
calculated is along an escape route, as defined by EN1838, measuring 5 m2 in total. The
chosen configuration is attributable to the majority of escape route wall installations. The
calculations refer to the ground and do not account for reflections, with a maintenance
factor of 0.8.
EN 1838: minimum 1 lx along the central line.
3 m
2 m
1 m
5 m
Escape routes ceiling mountingConfiguration chosen: Undefined corridor length, width 2m, height 3m. Installation height 3m.
CEILING mounted fixture, with main axis transversal to the greater axis of the room. The area
in which the portion of illuminance can be calculated is along an escape route, as defined by
EN1838, measuring 5 m2 in total. The chosen configuration is attributable to the majority of
escape route ceiling installations. The calculations refer to the ground and do not account for
reflections, with a maintenance factor of 0.8.
EN 1838: minimum 1 lx along the central line.
6 m
2 m
1 m
5 m
Escape routes ceiling mountingConfiguration chosen: Undefined corridor length, width 2m, height 6.5m. Installation height 6m.
CEILING mounted fixture, with main axis parallel to the greater axis of the room. The area in
which the portion of illuminance can be calculated is along an escape route, as defined by
EN1838, measuring 5 m2 in total. The chosen configuration is attributable to the majority of
escape route ceiling installations with a height of 6 m. The calculations refer to the ground and
do not account for reflections, with a maintenance factor of 0.8.
EN 1838: minimum 1 lx along the central line.
An outstanding technological profile and Beghelli brand value are
the hallmarks of a project to renew the light sources of emer-
gency lighting fixtures The use of high-efficiency LEDs and a cali-
brated light beam ensures adequate lighting and excellent
energy saving. The concept behind the Luce Utile project is
based on the need to have a light beam that is ideal for emer-
gency lighting while achieving the best illumination performance
possible. The optics have been designed specifically to solve
ground lighting problems with the lowest number of luminaires,
while conforming to the values of current standards.
ProjectLuceUtile
It doesn't matter how much light a luminaire emits.
It is what its light shows that is important,and transforms it into a useful light source.
All light apart from the controlled beamis a waste of energy.
The new age of emergency lighting
ATEX Directive
Appliance intended for use in environments with risk
of explosion due to the presence of combustible
dust or explosive substances in the following zones:
ZONE 02
Environment without explosive gas atmosphere
during normal operation, or with the former present in
rare occasions or for brief periods.
ZONE 22
Environment where the explosive atmosphere - in the
form of a combustible dust cloud – does not exist
during normal operation but, if present, persists for a
brief period.
Reference standards
94/9/CE
ATEX Directive of the European Parliament and Council dated
23/03/1994
CEI EN 60079-0:
Electrical apparatus for explosive atmospheres due to the
presence of gases: Part 0: General rules
CEI EN 60079-15:
Electrical apparatus for explosive atmospheres due to the
presence of gases: Part 15: Construction, testing and
marking of electrical apparatus with protection mode “n”.
CEI EN 61241-0:
Electrical apparatus intended for use in the presence
of combustible dust particles: Part 0: General provisions
CEI EN 61241-1:
Electrical apparatus intended for use in the presence
of combustible dust particles: Part 1: Protection
through “tD” casings.
Symbols
IP66Protection Rating relative to external factors
(in accordance with CEI EN 60598-1)
Fixture to be used in areas subject to explosion due to the
presence of explosive substances or dust according to the
ATEX Directive (see previous page)
IPPLUG
Invisible adapter included. It allows to install the
product either in tube ducts as in spiral conduct with
a diameter between 16 and 20, through a fast
connection system that reduce the size of the wired
product, speed the installation and grant the IP
protection degree of the fitting up to IP66.
F Appliances installable
on normally inflammable surfaces
Indicates the temperature of the incandescent
filament (EN 60598-1)850°C
Protection Rating relative to knocks to the
appliance in conformity to the test procedures
(in accordance with EN 50102)
IK09OTTICAURTI
Appliances with Class II insulation level.
Appliances without this symbol are to be regarded
as Class I appliances.
TE
ST Fitting equipped of magnetic sensor to execute a
functional test. The system provide a REED ampoule inside
the product and an included magnet to activate the test
Maximum viewing distance on the safety sign (VD)
according to UNI EN 1838
The value shown in the icon represents the distance
expressed in meters.
UNI EN 1838
30 m
12 HOURSCHARGING
Emergency lighting fittings equipped
with battery which grant
1 hour autonomy after 12 hours of recharge
Fixtures suitable for hospital�installations as per therequirements of art. 6.6 Italian Interior Ministry Decree 18
Sep. 2002 (2 hours of duration after 12 hours of charging)
HOSPEDALE
Self-contained Logica FM
emergency fittings
Self-contained Logica
emergency fittings
ATSelf-contained AutoTest
emergency fittings
TRSelf-contained emergency fittings
LG
LGFM
HTEmergency fittings supplied at 230V
UV
Fixtures characterised by special
resistance�to�UV�rays
UV-OIL
Fittings that can stand
to UV radiation and mineral oils
European quality label
ARCHITECTURAL SECTORS
Luxury hotels, design boutiques, historical buildings,
museums, show rooms, office districts
CIVIL SECTOR
residential buildings, small businesses
COMMERCIAL AND INDUSTRIAL SECTORS
Schools, public authorities, hotels and other kinds of
accommodation, offices, industrial
Products with 4-year extended warranty
80
5.1
80
.00