78
Lighthouse Worldwide Solutions

Lighthouse Overview Presentation Linkedin2

Embed Size (px)

DESCRIPTION

Lighthouse Worldwide Solutions Overview Presentation

Citation preview

Page 1: Lighthouse Overview Presentation Linkedin2

Lighthouse Worldwide Solutions

Page 2: Lighthouse Overview Presentation Linkedin2

Our CEO:

Silicon Valley Best

Places to Work

2 Years in a Row

2005, 2006!

Winner

Best Places to Work in Bay Area

Page 3: Lighthouse Overview Presentation Linkedin2

Fremont, CA

Research & Development

Engineering

Pilot Production

Executive Management

R&D / HQ: Manufacturing

Medford, OR

Manufacturing Operations

Service & Repair Center

Central Calibration Lab

RMA Center

Medford, OR

Fremont, CA

Page 4: Lighthouse Overview Presentation Linkedin2

New Headquarters: Silicon Valley

Page 5: Lighthouse Overview Presentation Linkedin2

Lighthouse Focus on Quality ISO 9001:2000 Facilities

United States:

Medford, OR

San Jose, CA

The

Netherlands:

Alphen Singapore

5 Lighthouse Locations are ISO 9000 Registered

Thailand

Page 6: Lighthouse Overview Presentation Linkedin2

Monitoring Solutions

Air/Liquid/Gas Particle

Temperature/Humidity

Air Velocity

Differential Pressure

Electrostatic Charge

TOC

General Monitoring

Current on FFU’s

Chillers

Door Switches

Oven Temp

Dry Box Humidity

Gas Purity

Large LCD Displays

Specific Applications

Page 7: Lighthouse Overview Presentation Linkedin2

Process and Environmental

Monitoring

Page 8: Lighthouse Overview Presentation Linkedin2

Process Monitoring

• Sample locations as close as possible

to the critical process areas to help

correlate high counts to yield issues.

Page 9: Lighthouse Overview Presentation Linkedin2

Environmental Monitoring

Temperature/Humidity Sensors

Room

Ovens

Freezers

Differential Pressure

Room to Room

Mini Environment

Air Velocity

Cleanroom

Ducts

Page 10: Lighthouse Overview Presentation Linkedin2

Environmental Monitoring

APC DP TRH

Air

Velocity Particle

Multiple DP Sensors

Humidity Inside Fridge TRH Sensor

Air Velocity in Duct

Page 11: Lighthouse Overview Presentation Linkedin2

Environmental Monitoring

Replace your

Magnahelic

Pressure Sensors Air Velocity in a Duct

Monitor Air

Velocity in Ducts

Page 12: Lighthouse Overview Presentation Linkedin2

Environmental Monitoring

Dry Box Humidity and Particle

Fluid or Tank

Levels

Incubator

Temperature

Page 13: Lighthouse Overview Presentation Linkedin2

Leak Detection

Real Time Leak Detection

Analog Signal

Page 14: Lighthouse Overview Presentation Linkedin2

Power Monitoring

Voltage Monitoring

Current Monitoring

Split or Solid Core

4 – 20mA Output

Page 15: Lighthouse Overview Presentation Linkedin2

Particle Monitoring in Ducts

0.2 to 100 Micron

Early Warning System

Immediately Notification of

Catastrophic Failure

Page 16: Lighthouse Overview Presentation Linkedin2

Lab Monitoring

Page 17: Lighthouse Overview Presentation Linkedin2

Lab Monitoring

Page 18: Lighthouse Overview Presentation Linkedin2

Lab Monitoring

Transmitter

Thermocouple

Replacing

Chart

Recorders

Temperature

Page 19: Lighthouse Overview Presentation Linkedin2

Refrigerator/Freezer

Dual

Transmitter

Local Display

Replacing Chart Recorders

Temperature

Page 20: Lighthouse Overview Presentation Linkedin2

Tank Levels and Status

Cryo Tank

LN2 Tank Level

LN2 Tank Lid (Open/Closed)

LN2 Bulk Tank Level

Co2 Tank Level

Oxygen Sensor

Page 21: Lighthouse Overview Presentation Linkedin2

Differential Pressure

4 – 20mA Output

Gown Room Pressure

Cleanroom Pressure

Differential Pressure

Page 22: Lighthouse Overview Presentation Linkedin2

Incubator

Temperature

Humidity

C02

Door is open/closed

Page 23: Lighthouse Overview Presentation Linkedin2

HVAC System

HVAC Status

Temperature

Power Consumption

Page 24: Lighthouse Overview Presentation Linkedin2

Power Monitoring

Voltage Monitoring

Current Monitoring

Split or Solid Core

4 – 20mA Output

Page 25: Lighthouse Overview Presentation Linkedin2

Lab Monitoring

APC in Flow

Bench

APC in Flow

Bench APC in Flow

Bench

Differential

Pressure

Temp/Hum

Alarm

Light

Wireless

Temp inside

Incubator

Page 26: Lighthouse Overview Presentation Linkedin2

Wireless

Wireless Temp Sensor

with Internal Probe

Particle

Receiver

Wireless Temp/Humidity

Sensor with External

Probe

Wireless Converter

(4 – 20mA to Wireless)

Differential

Pressure

Considerations:

Building Construction

Installation (inside or outside)

Distances

Sampling Frequency

Response Time

Battery Life vs. Powered

Page 27: Lighthouse Overview Presentation Linkedin2

Power Savings

Page 28: Lighthouse Overview Presentation Linkedin2

Power Savings

Typical Flow Rates 70 – 120 FPM

Reduced Air Changes = Power

Savings

Particle Counters Used to Verify

Performance

Particle Count Data is fed back to

HVAC system

VFD is required for FFU or HVAC

system

Page 29: Lighthouse Overview Presentation Linkedin2

Power Savings

Step 1: Verify room performance

through certification

Step 2: Select optimum sample

locations (Critical and Busy Sampling)

Step 3: Lower FFU speed and

monitor for an increase in particle

counts.

Step 4: Set new acceptable air flow

rate based on testing

Step 5: Set alarming parameters

Step 6: Install the system

Reduced Air Changes = Power

Savings

Particle Counters Used to Verify

Performance

Air Velocity and Particle Data

Page 30: Lighthouse Overview Presentation Linkedin2

Products

Slide 30 Lighthouse Worldwide Solutions CONFIDENTIAL

Page 31: Lighthouse Overview Presentation Linkedin2

World’s Number One Particle Counters!

Lighthouse Family of Products

Slide 31 Lighthouse Worldwide Solutions CONFIDENTIAL

Page 32: Lighthouse Overview Presentation Linkedin2

Airborne Particle Counting

Page 33: Lighthouse Overview Presentation Linkedin2

Particle Counters: HANDHELD

* Handheld 2016

* Handheld 3016

* Handheld 5016

* Handheld 3016 IAQ

Touch Screen Interface

Removable Battery

Temp/Hum Probe

Page 34: Lighthouse Overview Presentation Linkedin2

Portable Particle Counters: SOLAIR

SOLAIR 5100 / 3100

0.5 / 0.3 Micron

1.0 CFM

SOLAIR 5200 / 3200

0.5 / 0.3 Micron

2.0 CFM or 50 Liters per Minute

SOLAIR 1100LD

0.1 Micron

1.0 CFM

Touch Screen Interface

Removable Battery

Alphanumeric Location Labels

Page 35: Lighthouse Overview Presentation Linkedin2

Portable Particle Counters: SOLAIR

Boulder Counter

0.5 to 100 Micron

1.0 CFM

SOLAIR 5350 / 3350

0.5/0.3 Micron

3.5 CFM or 100 Liters per Minute

Easy to Use Interface

Sample Setup

Historical Data Review

Page 36: Lighthouse Overview Presentation Linkedin2

SOLAIR 1100LD GSO (Gas Sampling Option)

8 Particle Channel Sizes

Wide Dynamic Range, 0.1 to 5.0 µM

Battery Powered

Customizable Gas Sampling Recipes

3,000 Sample Records

May be Used with Any Inert Gases

Auto Flow Rate Compensation

ensures accurate measurement

Gases Sampled: Argon, Nitrogen,

Carbon Dioxide, Helium, CDA,

Neon, Xenon

Slide 36 Lighthouse Worldwide Solutions CONFIDENTIAL

Page 37: Lighthouse Overview Presentation Linkedin2

Particle Counters: REMOTE

Remote 2010/3010/5010

0.2/0.3/0.5 Micron Detection

0.1 CFM Air Flow

Pulse Communication

Remote 2012/3012/5012

0.2/0.3/0.5 Micron Detection

0.1 CFM Air Flow

0.1 Analog (4 -20mA) Communication

Page 38: Lighthouse Overview Presentation Linkedin2

Remote 5104P / 3104P

Remote Particle Counter w/Pump

Supports Remote Display

Interface: USB, RS-485 or Ethernet

HEPA Filter Cooling Fan Exhaust

and Pump Exhaust

Interface with Manifold

32 Port

6 Port

Reduced Cost for Manifold

Systems

Slide 38 Lighthouse Worldwide Solutions CONFIDENTIAL

Page 39: Lighthouse Overview Presentation Linkedin2

39

Remote 5104PN / 5102PN

Remote 5104PN: Modbus

Remote 5102PN: 4-20mA

1.0 CFM (28.3 LPM) Flow Rate

Built In Pump

Filter Pump Exhaust

Pump Start / Stop via Software

(5104PN)

Stainless Steel Construction 316L

Wipe-down Enclosure

90-240 VAC Power (50/60Hz)

Page 40: Lighthouse Overview Presentation Linkedin2

Manifolds:

Universal Manifold

32 Sample Locations

1.0 CFM

Works with Lighthouse and Met One Particle Counters

Mini Manifold

6 Sample Locations

0.1 CFM

4 Analog Inputs

Mini Manifold+

6 Sample Locations

1.0 CFM

Mini-Manifold

&

0.2 Micron

Particle

Counter

FanHEPA / ULPA

Filter

Particle Shedding /

Generation

Mini-Environment Monitoring

With Mini-Manifold & Single

Particle Counter

Page 41: Lighthouse Overview Presentation Linkedin2

TOC Monitoring

Page 42: Lighthouse Overview Presentation Linkedin2

Neptune TOC

Patent Pending UVX

Technology

TOC Range: 0.05 ppb to 1000

ppb

Repeatability: <5 ppb, 0.05

ppb; >5 ppb, 5%ppb

Conductivity Range: 0.055 to

2 uS/cm

Resistivity Range: 0.5 to

18.24 MOhm*cm

NeptuneTOC - Pharma 21-JUL-2011

Page 43: Lighthouse Overview Presentation Linkedin2

Neptune TOC

Interfaces

Ethernet -

MODBUS/TCP

Isolated RS232/485 -

MODBUS ASCII/RTU

Four Channels 4-20mA

Output

Four Relay Outputs

NeptuneTOC - Pharma 21-JUL-2011

Page 44: Lighthouse Overview Presentation Linkedin2

Neptune TOC

Two Year Warranty

Dimensions: 18.3 x 20.3 x 21

cm

[7.2” x 8” x 8.25”]

Weight: 0.21 kg [7.22 lbs.]

Power: 24VDC @ 1.5 Amps

Operating Temperature: 5 to

50 C, 0% to 95% non-

condensing Relative

Humidity

NeptuneTOC - Pharma 21-JUL-2011

Page 45: Lighthouse Overview Presentation Linkedin2

Liquid Particle Counting

Page 46: Lighthouse Overview Presentation Linkedin2

Liquid Particle Counting: Online

Remote LPC 0.5

0.5 – 20 Micron

4 Channels

100 mL Flow Rate

Remote LPC 0.2

0.2 – 2.0 Micron

4 Channels

100 mL Flow Rate

Remote LPC 0.3

0.3 – 3.0 Micron

4 Channels

100 mL Flow Rate

Remote LPC 0.1

0.1 – 0.5 Micron

4 Channels

100 mL Flow Rate

Page 47: Lighthouse Overview Presentation Linkedin2

Local Display

Higher Sensitivity

Higher Sample Volume

25nM Sensitivity

Advanced NanoCount 25, 30 and 50

Slide 47 Lighthouse Worldwide Solutions CONFIDENTIAL

Page 48: Lighthouse Overview Presentation Linkedin2

Liquid Particle Counting: Batch Sampling System

Page 49: Lighthouse Overview Presentation Linkedin2

Systems

Page 50: Lighthouse Overview Presentation Linkedin2

Online Systems – Star Configuration

Alarm

Light

TRH

Sensor

DP

Sensor

Optional Items Vacuum

pump

Vacuum Gauge

Vacuum Manifold

6 Real Time Particle Counters with External Vacuum Pump

Data Hub

- Ethernet or Modbus Output

- Supplies Power to Remotes

RS-485 MODBUS

Real Time

Software

Power From

Data Hub

Page 51: Lighthouse Overview Presentation Linkedin2

Online Systems- Network Configuration

4 Real Time Particle Counters with Built in Vacuum Pump

Over Ethernet

Real Time

Software

Built in Vacuum

Pumps

LAN

Power

and Ethernet

eth

ern

et

psPower

and Ethernet

eth

ern

et

ps Power

and Ethernet

eth

ern

et

ps Power

and Ethernet

eth

ern

et

ps

View

Station

View

Station

Alarm

Light

TRH

Sensor

DP

Sensor

Optional Items

Page 52: Lighthouse Overview Presentation Linkedin2

Online Systems

Alarm

Light

TRH

Sensor

DP

Sensor

Optional Items

Manifold Sampling System

RS-485 MODBUS

Real Time

Software

Particle Counter and

Sequential Sampling Manifold

Up to 32 Sample Ports

Data Hub

- Ethernet or Modbus Output

Page 53: Lighthouse Overview Presentation Linkedin2

Online System with Server

Page 54: Lighthouse Overview Presentation Linkedin2

Online System with Server

Page 55: Lighthouse Overview Presentation Linkedin2

Portable Cart System

Real time monitoring of

multiple locations

Troubleshoot the

Process

Identify particle sources

quickly

Characterize the process

Qualify the tool

Page 56: Lighthouse Overview Presentation Linkedin2

Software

Page 57: Lighthouse Overview Presentation Linkedin2

Ultimate in Scalability

57

LMS Professional Monitoring System is designed

to scale from a single point to thousands of

points and still maintain the same look and feel.

Building 1

Building 2

Building 3

Central System

Page 58: Lighthouse Overview Presentation Linkedin2

Redundancy

58

Redundant Data Acquisition (failover)

Automatic Recovery (fail-back)

No Loss of Existing Calculations,

Summations or Processes

Redundant Clients

No Operator Intervention Required

Mirrored Historical Data

Page 59: Lighthouse Overview Presentation Linkedin2

59

Data Communication: Wireless Network

Eth

ern

et

LWS

Wireless

Adapter

Wireless

Adapter

Wireless

Adapter

Page 60: Lighthouse Overview Presentation Linkedin2

Connectivity

The Lighthouse Monitoring

System is designed to meet all

your monitoring needs.

Connectivity:

4 – 20 mA

MODBUS

Ethernet

Digital Input

Digital Output

Thermocouple

RTD

OPC

Page 61: Lighthouse Overview Presentation Linkedin2

Connectivity

The Lighthouse Monitoring System can be can send and or receive

data from other types of Building Automation, SCADA or Control

Based Systems.

Common Interface Between Systems Are:

OPC

MODBUS TCP or MODBUS ASCII

Profi Bus

Device Net

The database is ODBC/SQL Compliant

LWS

Database

ODBC

SQL

Compliant

Page 62: Lighthouse Overview Presentation Linkedin2

Connectivity

Page 63: Lighthouse Overview Presentation Linkedin2

Main Screen

63

Page 64: Lighthouse Overview Presentation Linkedin2

Multilevel Maps

Drill Down Maps allow

you to see an overview

of the facility and then

status of a specific

room

Unique Sensor

Shapes

Page 65: Lighthouse Overview Presentation Linkedin2

From Map to Graph

Lighthouse Worldwide Solutions CONFIDENTIAL 65

Simple Mouse Click

Navigation to the Data

You Want to See…

Page 66: Lighthouse Overview Presentation Linkedin2

Logical System Structure

Page 67: Lighthouse Overview Presentation Linkedin2

List Screen

Lighthouse Worldwide Solutions CONFIDENTIAL

View All Sensors Status

Real Time Color Status

Real Time Data Status

Location Name

Values

Date and Time

Sort by Status

Acknowledge an Alarm

Display a Trend

Disable/Enable Alarms

Configure

Locate a Sensor

Click n Go

Page 68: Lighthouse Overview Presentation Linkedin2

68

Schedules Setup a scheduled event based

on date and time.

Turn on/off a pump

Automatically change alarm

limits

Trigger sampling recipes

Print Reports

Stop recording data

Page 69: Lighthouse Overview Presentation Linkedin2

Status Screen

Lighthouse Worldwide Solutions CONFIDENTIAL 69

View All Sensors Status

Real Time Color Status

Real Time Data Status

Location Name

Values

Date and Time

Current/Historical Graphs

Alarm Acknowledgment

Mouse Click Menu

Selection Simplifies

Use…

Click n Go

Page 70: Lighthouse Overview Presentation Linkedin2

Report Function

70

Conformance Report

Raw Data by Channel Size

Color Coded

Summary of Events

# of Measurements

# of Warnings

# of Alarms

Min

Max

Average

Mean

Standard Deviation

Graphs of Selected Points

Page 71: Lighthouse Overview Presentation Linkedin2

Simplified Deployment

71

Templates and Recipes allow for easy and consistent

deployment of monitoring changes across multiple sites.

Export E-mail Import

Remote Desktop

USA

Singapore

Thailand

China

Page 72: Lighthouse Overview Presentation Linkedin2

DROID Based Application

72

DROID Powered Tablet

DROID Powered Phone

Watch and Receive Your

System Information on

the go…

Page 73: Lighthouse Overview Presentation Linkedin2

Installation

and

Service

Page 74: Lighthouse Overview Presentation Linkedin2

ISO 21501 Calibration Standards

Improved Reproducibility

Greater Counting Accuracy

Increased Testing to Minimize Errors

Enhanced Correlation between

Instruments

ISO 21501 Summary:

Size Calibrated

Particle Count Verification

Size Resolution

False Count Rate Verification

Maximum Concentration Limit Verification

Flow Rate Verification

Sample Time Verification

Sample Volume Verification

Page 75: Lighthouse Overview Presentation Linkedin2

Installation Services

Mounting Styles (Fixed Probes vs.

Movable Probes)

Probe Locations

Tool Integrated Probes

Wall Mounted Fixtures

Non-Viable & Viable Probes

Custom Fixtures & Conduits

Getting the utilities to the

instrumentation is key

NEMA 4X enclosures

Page 76: Lighthouse Overview Presentation Linkedin2

Validation Services

Requirements Documents

Design Qualification

Installation Qualification

Operational Qualification

Performance Qualification

SOPs

Page 77: Lighthouse Overview Presentation Linkedin2

Training Services

Monitoring System Training

User Level

Administer Level

Service

Calibration Training (Optional)

Contamination Training

Cleanroom Protocol Training

Page 78: Lighthouse Overview Presentation Linkedin2

Contact us at 510-438-0500

or

www.golighthouse.com

Slide 78 Lighthouse Worldwide Solutions CONFIDENTIAL