Level 1.5 Processing Updates
Martin Bates, RAL
GIST 24
15th December, 2005
Contents
• Geolocation– optical models for V999 reprocessing– updates for and since Oct 2005
• Calibration Processing– fixed gains
• What else do we need/want for release ? (non-GEO)– confidence flags (QF anomaly)– handling of anomalies (counting data)– ARG duplication ?
Optical Models
Square: 20040601
Cross: 20040722
Star: 20050115
very basic: just use col 140 from one TOTAL image at midday
Use detector “banana” based on RGP L15G optimal fits
Had been been using detector banana derived from lab PSF measurements (+ modelling)
Used in V999 reprocessing, and in nrt system from Oct 05 restart
Automated Monitoring Plots
Automated shortly after Oct restart
Incorporated in eng plots beginning of December
Used to spot E/W, N/S bulk shifts in GEO.
Crucial if relying on manual interventions to maintain level
1.5 geo quality.
Column Azimuth
SOL_SOE → “even” cols shifted wrt “odd”
SOL_SOE noisy → column spacing noisy
Limb scans in July 2003: columns are evenly spaced
Column spacing (before)
Column Spacing (after)CR-069 (non-parallel mirror): Implemented at Oct 29 start-
up
CR-070 (SOL_SOE fit): Implemented 14 Nov 11:52
CR-070 not ideal: lose any information on non-uniform column spacing
October 2005
• Restart with optical model as for Dec 04 reproc
• Retuned to match geolocation for Aug 17.
• On start-up, needed to tune N/S by 0.75 pixels (done 03 Nov).
Calibration
• Running average gains implemented 20-Jul-2005 (and used in V999 reprocessing).
• Minor start-up effects seen Oct 2005– “warm” or “cold” start
debate
• Handling of outliers a potential issue– can be caused by anomalies
(see later)
What is missing from processing for release ?
• Confidence Flags
• NCR fixes
• ARG duplication
What is missing from processing for release ?
• What do we absolutely need for release ?
• What should we include if we can do it “quickly”
• What is not important for this release ?
What is missing from processing for release ?
• Confidence Flags:– 0: QF Anomaly– 1: Direct Stray Light affecting image– 2: Direct Stray Light affecting gains (no gain update)– 3: Diffuse Stray Light– 4: Stray Light in black body– (5-8: Spare stray light fields)– 9: Black body temperature anomaly– 10: Detector temperature warning– 11: Detector temperature alarm– 12: Using cal history for CAL (n/a with running ave. gains)– 13: UTC time stamp errors– 14: Recent orbit manoeuvre– 15: SEVIRI off in last 6 hours– 16: Start of Line Jitter– 17: Scan Mirror Jitter (SOL_SOE, other TBD).– 18: Using out of date TSOL Jitter values
Quartz Filter Anomaly
SOL noise
e.g. eclipse 02 Nov 2005
What is missing from processing for release ?
• Confidence Flags:
• NCR fixes– Trap counting data (NCR-195)– Distinguish sun-glint from byte-shift data
(NCR-164)
• ARG duplication
Trap Counting Data (NCR-195)
Distinguish sunglint/byteshift data (NCR-164)
What is missing from processing for release ?
• Confidence Flags
• NCR fixes
• (L2) ARG renaming– G2_SEV1_L20L_20051210_120000_V002.hdf
or– G2_SEV1_L20L_20051210_115325_V001.hdf