2
LEAFLET 200 INDICATOR VALVE CAPS Damaged or dirty indicator valve threads make measuring cylinder pressures on a hot engine difficult and time consuming. Keep those threads ready to go with KIENE “PRO-TEK-TOR” and “POS-I-SEAL” indicator valve caps. ORDERING INFORMATION: Part No. Description AX-17 PRO-TEK-TOR Cap with Lanyard AX-17A POS-I-SEAL Cap with Lanyard AX-17AB POS-I-SEAL Cap, 316SS Plug, with Lanyard AX-17B PRO-TEK-TOR Cap (316SS) with Lanyard AX-22 Discontinued. Replaced by AX-17. AX-23 Discontinued. Replaced by AX-17A. AX-55 PRO-TEK-TOR-type Cap with Integral Heat Shield AX-18 NU-THRED DIE For dressing or cleaning damaged or corroded indicator threads used on most indicator valves and adapters. The carbon steel NU-THRED DIE is hexagon- shaped, for convenient hand operation. The NU-THRED DIE is 1-1/8” across the flats and features six thread faces (1 1/16”-10 Whitworth and 1” thread width). AX-19 T-HANDLE WRENCH The 5/8” integral socket T-handle wrench is recommended for opening and closing all V-line indicator valves. It prevents over -tightening of the valve stem. INDICATOR VALVE ACCESSORIES Visit our website at www.kienediesel.com E-mail: [email protected] 325 South Fairbank Street, Addison, Illinois, 60101 • Telephone: 1-800-264-5950 • Fax: 630-543-5953 Handy Lanyard—now included with all KIENE valve caps. AX-18 NU-THRED DIE AX-19 T-HANDLE WRENCH AX-17A POS-I-SEAL Cap Protects and seals the indicator connection. AX-17 PRO-TEK-TOR Cap Protects the indicator connection from damage and dirt accumulation. AX-55 Valve Cap with Heat Shield Improved plug design will not stick in valve socket. 12/14/2017 Plastic heat shield reduces the possibility of accidentally touching a hot valve surface.

LEAFLET 200 INDICATOR VALVE ACCESSORIES VALVE ACCE… · valves), and Leaflet 155 (A-line valves). AX-34 CYLINDER LEAKAGE ADAPTER The AX-34 is a handy device. Use it do a quick leak

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LEAFLET 200 INDICATOR VALVE ACCESSORIES VALVE ACCE… · valves), and Leaflet 155 (A-line valves). AX-34 CYLINDER LEAKAGE ADAPTER The AX-34 is a handy device. Use it do a quick leak

LEAFLET 200

INDICATOR VALVE CAPS Damaged or dirty indicator valve threads make measuring cylinder pressures on a hot engine difficult and time consuming. Keep those threads ready to

go with KIENE “PRO-TEK-TOR” and “POS-I-SEAL” indicator valve caps.

ORDERING INFORMATION:

Part No. Description

AX-17 PRO-TEK-TOR Cap with Lanyard AX-17A POS-I-SEAL Cap with Lanyard

AX-17AB POS-I-SEAL Cap, 316SS Plug, with Lanyard AX-17B PRO-TEK-TOR Cap (316SS) with Lanyard AX-22 Discontinued. Replaced by AX-17. AX-23 Discontinued. Replaced by AX-17A. AX-55 PRO-TEK-TOR-type Cap with Integral Heat Shield

AX-18 NU-THRED DIE For dressing or cleaning damaged or corroded indicator threads used on most indicator valves and adapters. The carbon steel NU-THRED DIE is hexagon-shaped, for convenient hand operation. The NU-THRED DIE is 1-1/8” across the flats and features six thread faces (1 1/16”-10 Whitworth and 1” thread width).

AX-19 T-HANDLE WRENCH The 5/8” integral socket T-handle wrench is recommended for opening and closing all V-line indicator valves. It prevents over-tightening of the valve stem.

INDICATOR VALVE

ACCESSORIES

Visit our website at www.kienediesel.com E-mail: [email protected]

325 South Fairbank Street, Addison, Illinois, 60101 • Telephone: 1-800-264-5950 • Fax: 630-543-5953

Handy Lanyard—now included

with all KIENE valve caps.

AX-18 NU-THRED DIE AX-19 T-HANDLE WRENCH

AX-17A POS-I-SEAL Cap Protects and seals the indicator connection.

AX-17 PRO-TEK-TOR Cap Protects the indicator connection

from damage and dirt accumulation.

AX-55 Valve Cap with Heat Shield

Improved plug design will not stick in valve socket.

12/14/2017

Plastic heat shield reduces the possibility of accidentally touching

a hot valve surface.

Page 2: LEAFLET 200 INDICATOR VALVE ACCESSORIES VALVE ACCE… · valves), and Leaflet 155 (A-line valves). AX-34 CYLINDER LEAKAGE ADAPTER The AX-34 is a handy device. Use it do a quick leak

Visit our website at www.kienediesel.com E-mail: [email protected]

325 South Fairbank Street, Addison, Illinois, 60101 • Telephone: 1-800-264-5950 • Fax: 630-543-5953

Furnished complete with carrying case and tools.

INDICATOR VALVES KIENE indicator valves are the industry standard - specified by more engine builders and more major engine operators than any other valve on the market. Features include a small turn radius, Kiene design concept of “opening against and closing with” engine pressure, and a standard indicator connection. V-line indicator valves are available for most normal engine applications. A-line, or offset valves, are designed for applications requiring an offset indicator connection. Valves are available in a variety of engine thread sizes, with or without an integral extension. For complete details request Leaflets 150 and 152 (V-line valves), and Leaflet 155 (A-line valves).

AX-34 CYLINDER LEAKAGE ADAPTER The AX-34 is a handy device. Use it do a quick leak check by connecting it to an indicator valve and applying air to an engine or compressor cylinder. 1/4 quick-disconnect coupling provided.

POSITIONING SHIMS These shims will allow you to change the rotational position of an indicator valve. Each shim rotates the valve by approximately 90°.

ORDERING INFORMATION:

Part No. For Valves:

AX-41 V-39

AX-42 V-12, V-12A, V-12B, V-12C

AX-43 V-24A

AX-36 PROTECTIVE COVER The AX-36 is made of flexible, high-temperature materials - the same materials used in exhaust insulation systems. It is a fast way to prevent accidental contact with hot valve surfaces. Excellent for EMD engines.

CYLINDER PRESSURE INDICATOR Based on the “Trapped Pressure” principle, the KIENE K-100 series of cylinder pressure indicators are available in a variety of pressure ranges and suitable for natural gas or diesel engines. They are simple to use, accurate, easy to read and, above all, the most economical indicator available today. The Kiene indicator is used and recommended by major engine builders. Ask for Leaflet 100 and specify your application - natural gas or diesel.