Abstract Thirty-five patients with 36 displaced distal femoral fractures (16 AO-type C2 and 19 AO-type C3) were treated with an anterior approach and double plat- ing and followed for an average of 7 (3–44) months. Bone grafting with allograft and demineralized bone ma- trix was used. Postoperative therapy included immediate ROM and non-weight bearing for 12 weeks. Two pa- tients died during hospitalization and one was lost to fol- low-up. Reductions were near anatomic in all but three patients. Uneventful healing by 16 weeks occurred in 24/36 fractures. Double plating via the anterolateral ap- proach minimized stripping of the medial side and im- proved controlled access to the distal femur. Résumé Trente-cinq malades avec 36 fractures fémora- les distales déplacées (16 de type AO C2 et 19 de type C3) ont été traité par un abord antérieur, une ostéosyn- thèse par deux plaques et ont eu un suivi de 7 mois en moyenne (3 à 44 mois). Des greffes par allogreffes et matrice osseuse déminéralisée ont été utilisées. Après l’intervention une mobilisation précoce et une décharge de 12 semaine ont été réalisées. Deux malades sont morts pendant l’hospitalisation, et 1 a été perdu de vue. La réduction des fractures était presque anatomique sauf dans 3 cas. La consolidation s’est produite sans incident en 16 semaines pour 24 des 36 fractures. L’ostéosynthèse avec 2 plaques par un abord antéro-externe minimise les délabrements internes et améliore l’accés au fémur dis- tal. Introduction Traditional techniques for treatment of AO type C frac- tures of the distal femur have utilized the lateral ap- proach with soft tissue preservation. Recent trials with minimally invasive plating techniques have been report- ed [1, 3] but can incur greater operative times and are technically challenging. Proper use of the lateral ap- proach can be difficult and can result in greater soft tis- sue dissection if not performed correctly. Although fa- vorable results have been reported using intramedullary (IM) nailing of distal femoral fractures [4, 7], other stud- ies have shown the IM nail to be inferior to plating with regard to mechanical properties such as stiffness [2, 5, 6]. Furthermore, IM nailing cannot be used for the more severe intraarticular fractures. Much like the traditional lateral approach, the anterior approach permits increased reduction and placement of fixation devices, exposes only the anterior and lateral as- pects of the femur, and avoids unintentional medial dis- section. Furthermore, both an anterior and a lateral plate can be placed at 90° to each other to provide better struc- tural stability; the concept is somewhat analogous to fix- ation of the distal humerus. In this report, we provide a descriptive analysis of our experience with double plat- ing of the distal femur using a single anterior approach that minimizes excessive medial dissection while provid- ing excellent exposure. Materials and methods All displaced C2 and C3 (AO classification) distal femoral frac- tures (n=39) were treated utilizing an anterior approach and dou- ble plating. The anterior approach uses a lateral peripatellar ar- throtomy and lateral dissection of the vastus lateralis, and part of the intermedius from the femur (Figs. 1, 2, 3, and 4). The anterior dissection was limited to avoid any medial dissection not already perpetrated by the injury. Hohman and Bennett-type retractors were strictly forbidden. After articular reduction was achieved, a lateral plate (condylar or blade) and anterior plate (reconstruction or 3.5 mm dynamic compression) were placed (Fig. 5). The anteri- or plate was contoured to lie just next to the articular surface of B.H. Ziran ( ) · R.H. Rohde · A.R. Wharton Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Kaufmann Bldg., Suite 1010, 3471 Fifth Avenue, Pittsburgh, PA, 15213–3221, USA e-mail: [email protected] Tel.: +1-412-6053327, Fax: +1-412-6873724 International Orthopaedics (SICOT) (2002) 26:370–373 DOI 10.1007/s00264-002-0383-z ORIGINAL PAPER B. H. Ziran · R. H. Rohde · A. R. Wharton Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach Accepted: 15 May 2002 / Published online: 18 July 2002 © Springer-Verlag 2002

Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach

  • Upload
    b-ziran

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach

Abstract Thirty-five patients with 36 displaced distalfemoral fractures (16 AO-type C2 and 19 AO-type C3)were treated with an anterior approach and double plat-ing and followed for an average of 7 (3–44) months.Bone grafting with allograft and demineralized bone ma-trix was used. Postoperative therapy included immediateROM and non-weight bearing for 12 weeks. Two pa-tients died during hospitalization and one was lost to fol-low-up. Reductions were near anatomic in all but threepatients. Uneventful healing by 16 weeks occurred in24/36 fractures. Double plating via the anterolateral ap-proach minimized stripping of the medial side and im-proved controlled access to the distal femur.

Résumé Trente-cinq malades avec 36 fractures fémora-les distales déplacées (16 de type AO C2 et 19 de typeC3) ont été traité par un abord antérieur, une ostéosyn-thèse par deux plaques et ont eu un suivi de 7 mois enmoyenne (3 à 44 mois). Des greffes par allogreffes etmatrice osseuse déminéralisée ont été utilisées. Aprèsl’intervention une mobilisation précoce et une déchargede 12 semaine ont été réalisées. Deux malades sontmorts pendant l’hospitalisation, et 1 a été perdu de vue.La réduction des fractures était presque anatomique saufdans 3 cas. La consolidation s’est produite sans incidenten 16 semaines pour 24 des 36 fractures. L’ostéosynthèseavec 2 plaques par un abord antéro-externe minimise lesdélabrements internes et améliore l’accés au fémur dis-tal.

Introduction

Traditional techniques for treatment of AO type C frac-tures of the distal femur have utilized the lateral ap-proach with soft tissue preservation. Recent trials withminimally invasive plating techniques have been report-ed [1, 3] but can incur greater operative times and aretechnically challenging. Proper use of the lateral ap-proach can be difficult and can result in greater soft tis-sue dissection if not performed correctly. Although fa-vorable results have been reported using intramedullary(IM) nailing of distal femoral fractures [4, 7], other stud-ies have shown the IM nail to be inferior to plating withregard to mechanical properties such as stiffness [2, 5,6]. Furthermore, IM nailing cannot be used for the moresevere intraarticular fractures.

Much like the traditional lateral approach, the anteriorapproach permits increased reduction and placement offixation devices, exposes only the anterior and lateral as-pects of the femur, and avoids unintentional medial dis-section. Furthermore, both an anterior and a lateral platecan be placed at 90° to each other to provide better struc-tural stability; the concept is somewhat analogous to fix-ation of the distal humerus. In this report, we provide adescriptive analysis of our experience with double plat-ing of the distal femur using a single anterior approachthat minimizes excessive medial dissection while provid-ing excellent exposure.

Materials and methods

All displaced C2 and C3 (AO classification) distal femoral frac-tures (n=39) were treated utilizing an anterior approach and dou-ble plating. The anterior approach uses a lateral peripatellar ar-throtomy and lateral dissection of the vastus lateralis, and part ofthe intermedius from the femur (Figs. 1, 2, 3, and 4). The anteriordissection was limited to avoid any medial dissection not alreadyperpetrated by the injury. Hohman and Bennett-type retractorswere strictly forbidden. After articular reduction was achieved, alateral plate (condylar or blade) and anterior plate (reconstructionor 3.5 mm dynamic compression) were placed (Fig. 5). The anteri-or plate was contoured to lie just next to the articular surface of

B.H. Ziran (✉) · R.H. Rohde · A.R. WhartonDepartment of Orthopaedic Surgery, University of Pittsburgh Medical Center, Kaufmann Bldg., Suite 1010, 3471 Fifth Avenue, Pittsburgh, PA, 15213–3221, USAe-mail: [email protected].: +1-412-6053327, Fax: +1-412-6873724

International Orthopaedics (SICOT) (2002) 26:370–373DOI 10.1007/s00264-002-0383-z

O R I G I N A L PA P E R

B. H. Ziran · R. H. Rohde · A. R. Wharton

Lateral and anterior plating of intra-articular distal femoral fracturestreated via an anterior approach

Accepted: 15 May 2002 / Published online: 18 July 2002© Springer-Verlag 2002

Verwendete Distiller 5.0.x Joboptions
Dieser Report wurde automatisch mit Hilfe der Adobe Acrobat Distiller Erweiterung "Distiller Secrets v1.0.5" der IMPRESSED GmbH erstellt. Sie koennen diese Startup-Datei für die Distiller Versionen 4.0.5 und 5.0.x kostenlos unter http://www.impressed.de herunterladen. ALLGEMEIN ---------------------------------------- Dateioptionen: Kompatibilität: PDF 1.2 Für schnelle Web-Anzeige optimieren: Ja Piktogramme einbetten: Ja Seiten automatisch drehen: Nein Seiten von: 1 Seiten bis: Alle Seiten Bund: Links Auflösung: [ 600 600 ] dpi Papierformat: [ 595 785 ] Punkt KOMPRIMIERUNG ---------------------------------------- Farbbilder: Downsampling: Ja Berechnungsmethode: Bikubische Neuberechnung Downsample-Auflösung: 150 dpi Downsampling für Bilder über: 225 dpi Komprimieren: Ja Automatische Bestimmung der Komprimierungsart: Ja JPEG-Qualität: Mittel Bitanzahl pro Pixel: Wie Original Bit Graustufenbilder: Downsampling: Ja Berechnungsmethode: Bikubische Neuberechnung Downsample-Auflösung: 150 dpi Downsampling für Bilder über: 225 dpi Komprimieren: Ja Automatische Bestimmung der Komprimierungsart: Ja JPEG-Qualität: Mittel Bitanzahl pro Pixel: Wie Original Bit Schwarzweiß-Bilder: Downsampling: Ja Berechnungsmethode: Bikubische Neuberechnung Downsample-Auflösung: 600 dpi Downsampling für Bilder über: 900 dpi Komprimieren: Ja Komprimierungsart: CCITT CCITT-Gruppe: 4 Graustufen glätten: Nein Text und Vektorgrafiken komprimieren: Ja SCHRIFTEN ---------------------------------------- Alle Schriften einbetten: Ja Untergruppen aller eingebetteten Schriften: Nein Wenn Einbetten fehlschlägt: Warnen und weiter Einbetten: Immer einbetten: [ ] Nie einbetten: [ ] FARBE(N) ---------------------------------------- Farbmanagement: Farbumrechnungsmethode: Alle Farben zu sRGB konvertieren Methode: Standard Arbeitsbereiche: Graustufen ICC-Profil: RGB ICC-Profil: sRGB IEC61966-2.1 CMYK ICC-Profil: U.S. Web Coated (SWOP) v2 Geräteabhängige Daten: Einstellungen für Überdrucken beibehalten: Ja Unterfarbreduktion und Schwarzaufbau beibehalten: Ja Transferfunktionen: Anwenden Rastereinstellungen beibehalten: Ja ERWEITERT ---------------------------------------- Optionen: Prolog/Epilog verwenden: Nein PostScript-Datei darf Einstellungen überschreiben: Ja Level 2 copypage-Semantik beibehalten: Ja Portable Job Ticket in PDF-Datei speichern: Nein Illustrator-Überdruckmodus: Ja Farbverläufe zu weichen Nuancen konvertieren: Nein ASCII-Format: Nein Document Structuring Conventions (DSC): DSC-Kommentare verarbeiten: Nein ANDERE ---------------------------------------- Distiller-Kern Version: 5000 ZIP-Komprimierung verwenden: Ja Optimierungen deaktivieren: Nein Bildspeicher: 524288 Byte Farbbilder glätten: Nein Graustufenbilder glätten: Nein Bilder (< 257 Farben) in indizierten Farbraum konvertieren: Ja sRGB ICC-Profil: sRGB IEC61966-2.1 ENDE DES REPORTS ---------------------------------------- IMPRESSED GmbH Bahrenfelder Chaussee 49 22761 Hamburg, Germany Tel. +49 40 897189-0 Fax +49 40 897189-71 Email: [email protected] Web: www.impressed.de
Adobe Acrobat Distiller 5.0.x Joboption Datei
<< /ColorSettingsFile () /AntiAliasMonoImages false /CannotEmbedFontPolicy /Warning /ParseDSCComments false /DoThumbnails true /CompressPages true /CalRGBProfile (sRGB IEC61966-2.1) /MaxSubsetPct 100 /EncodeColorImages true /GrayImageFilter /DCTEncode /Optimize true /ParseDSCCommentsForDocInfo false /EmitDSCWarnings false /CalGrayProfile () /NeverEmbed [ ] /GrayImageDownsampleThreshold 1.5 /UsePrologue false /GrayImageDict << /QFactor 0.9 /Blend 1 /HSamples [ 2 1 1 2 ] /VSamples [ 2 1 1 2 ] >> /AutoFilterColorImages true /sRGBProfile (sRGB IEC61966-2.1) /ColorImageDepth -1 /PreserveOverprintSettings true /AutoRotatePages /None /UCRandBGInfo /Preserve /EmbedAllFonts true /CompatibilityLevel 1.2 /StartPage 1 /AntiAliasColorImages false /CreateJobTicket false /ConvertImagesToIndexed true /ColorImageDownsampleType /Bicubic /ColorImageDownsampleThreshold 1.5 /MonoImageDownsampleType /Bicubic /DetectBlends false /GrayImageDownsampleType /Bicubic /PreserveEPSInfo false /GrayACSImageDict << /VSamples [ 2 1 1 2 ] /QFactor 0.76 /Blend 1 /HSamples [ 2 1 1 2 ] /ColorTransform 1 >> /ColorACSImageDict << /VSamples [ 2 1 1 2 ] /QFactor 0.76 /Blend 1 /HSamples [ 2 1 1 2 ] /ColorTransform 1 >> /PreserveCopyPage true /EncodeMonoImages true /ColorConversionStrategy /sRGB /PreserveOPIComments false /AntiAliasGrayImages false /GrayImageDepth -1 /ColorImageResolution 150 /EndPage -1 /AutoPositionEPSFiles false /MonoImageDepth -1 /TransferFunctionInfo /Apply /EncodeGrayImages true /DownsampleGrayImages true /DownsampleMonoImages true /DownsampleColorImages true /MonoImageDownsampleThreshold 1.5 /MonoImageDict << /K -1 >> /Binding /Left /CalCMYKProfile (U.S. Web Coated (SWOP) v2) /MonoImageResolution 600 /AutoFilterGrayImages true /AlwaysEmbed [ ] /ImageMemory 524288 /SubsetFonts false /DefaultRenderingIntent /Default /OPM 1 /MonoImageFilter /CCITTFaxEncode /GrayImageResolution 150 /ColorImageFilter /DCTEncode /PreserveHalftoneInfo true /ColorImageDict << /QFactor 0.9 /Blend 1 /HSamples [ 2 1 1 2 ] /VSamples [ 2 1 1 2 ] >> /ASCII85EncodePages false /LockDistillerParams false >> setdistillerparams << /PageSize [ 595.276 841.890 ] /HWResolution [ 600 600 ] >> setpagedevice
Page 2: Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach

371

the medial trochlea. Gentle flexion facilitated articular visualiza-tion, when needed (Fig. 6.) All open fractures were treated withaggressive debridement and antibiotic beads, with temporary ex-ternal fixation followed by definitive stabilization and soft-tissuecoverage within 1 week. Bone grafting with allograft and deminer-alized bone matrix (DBM) was used in all but eight femurs (sevenpatients), because of the severity of bone loss or comminution.The main technical difficulty with this exposure is proximal screwplacement in the lateral plate. Because the quadriceps are split an-teriorly, some of the lateral screws were placed percutaneously.

The postoperative physiotherapy included immediate (0°–30°)and graduated (15°/10 days) motion and no weight bearing for atleast 12 weeks. In the more severe cases, external fixation wasmaintained for 2–4 weeks, after which patients began graduatedmotion. In addition to demographic and routine clinical data, weanalyzed fracture pattern, method of fixation, technical problems,

and complications. Healing was determined clinically and radio-graphically. Follow-up was performed at 2, 6, 12, 24, and 48weeks, and then annually.

Results

Thirty-five patients with 36 fractures were treated utiliz-ing this approach. There were 21 men and 14 women,with an average follow-up of 7.7 (range 3–44) months.Two patients died during hospitalization, one was lost tofollow-up, and two developed an infection – one of whichresulted in an amputation below the knee. There werefour G-I, five G-IIIA, one G-IIIB, two G-IIIC fractures,and 24 closed fractures. Using the AO classification,there were 16 C2 and 19 C3 fractures. Twenty-one pa-

Fig. 1 Cutaneous location of incision

Fig. 2 Subcutaneous exposure. Identify patellar and quadricepstendons. Limit undermining of skin

Fig. 3 Lateral peripatellar incision. Note exposure of lateral con-dylar area

Fig. 4 Intraarticular exposure with fracture easily identified. Iden-tify and tag margins of suprapatellar pouch to facilitate repair dur-ing closure. This will help minimize postoperative adhesions.Note that there is no medial dissection

Page 3: Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach

372

tients had associated injuries in the extremity. There were18 blade plates and 18 condylar plates used laterally. Tenreconstruction and 25 DC plates were used anteriorly.

Mean arc of motion was from 5° (range 5°–35°) to100° (range 20°–130°) flexion. In the three patients withsmall arcs of motion, physiotherapy was delayed for 6 weeks secondary to access difficulties (insurance autho-rizations). Five patients required manipulation of the kneeunder anesthesia to increase range of motion. In all fivepatients, there were other injuries to the extremities(grade 3 open tibia or ankle injuries requiring free flap)that interfered with their ability to move the knee in theearly postoperative period. In all of these patients, final

Fig. 5 View with fixation in place. An anterior plate is easilyplaced without “medial” dissection. The dissection is limited to thatcaused by the injury and only what “anterior” exposure is necessary.Often, a modified submuscular placement of the plate is possiblewith proximal and distal exposures. What medial dissection is need-ed generally is intraarticular and, if medial collateral and medialcapsular structures are preserved, there is little risk of devasculari-zing the medial articular fragments. Care is taken, however, to mini-mize the metaphyseal and diaphyseal medial dissection

Fig. 6 If needed, gentle flexion of the knee joint allows visualization

Fig. 7 Antero-posterior radiograph of C3 fracture fixed with twoplates

motion was between 0–100 to 70–900. One patient devel-oped a posttraumatic stress disorder that kept her fromtraveling in a car, and she subsequently received no thera-py for 3 months. She ended up with an arthrofibrosis of0°–20° of motion bilaterally. Excluding these patients, themean arc of motion for the group was from 1° to 102°.

Reductions were near anatomic (less than 2 mm ofstep-off, less than 5° of varus, and less than 1 cm ofshortening) in all but three patients. Uneventful healingby 16 weeks occurred in 24 of 36 fractures. There werethree nonunions. The anterior plate that was utilized fortwo patients with nonunion (each patient weighing in ex-cess of 350 lb, with long fracture spans) was a long re-construction plate. Both patients healed after a secondprocedure. Since then, only 3.5-mm DC plates have beenused as the anterior plate, especially with long fracturespans. One of the patients with infection (due to entericorganisms) was doing dressing changes on a superficialwound (originally G-IIIA open) after defecation withouthand washing. He underwent debridement and staged re-construction with subsequent healing. Figs. 7, 8, and 9

Fig. 8 Lateral radiograph of C3 fracture fixed with two plates

Page 4: Lateral and anterior plating of intra-articular distal femoral fractures treated via an anterior approach

ability of allograft and newer inductive agents allowedus to graft acutely without concern for pelvic donor sitemorbidity or availability. There is no evidence of anyadverse effects of acute grafting. There were no addi-tional problems with other perioperative complicationsusing this approach. In the four patients with stiffness, itwas felt that extensive damage to the suprapatellar tis-sues and lack of immediate early motion contributed tofibrosis in this area. Furthermore, an attempt was madeto repair the suprapatellar pouch whenever possible tominimize adhesions between the vastus musculature andthe bone.

Although the lateral approach is the accepted stan-dard, visualization of the articular surface and indirectreduction can be difficult and, far too often, the approachis not performed as intended – especially in inexperi-enced hands. The anterolateral approach provides excel-lent visualization without a biologic cost. An outcomeand cost analysis, as well as a comparative study, wouldhelp characterize the utility of this approach.

Acknowledgements We would like to acknowledge the instruc-tion and support of Michael W. Chapman

References

1. Bohlhofner BR, Carmen B, Clifford P (1996) The results ofopen reduction and internal fixation of distal femur fracturesusing a biologic (indirect) reduction technique. J Orthop Trau-ma 10: 372–377

2. Firoozbakhsh K, Behzadi K, DeCoster TA, Moneim MS, Naraghi FF (1995) Mechanics of retrograde nail versus platefixation for supracondylar femur fractures. J Orthop Trauma 9: 152–157

3. Henry SL (2000) Supracondylar femur fractures treated percu-taneously. Clin Orthop 375: 51–59

4. Iannacone WM, Bennett FS, DeLong WG, Born CT, DalseyRM (1994) Initial experience with the treatment of supracondy-lar femoral fractures using the supracondylar intramedullarynail: A preliminary report. J Orthop Trauma 8: 322–337

5. Koval KJ, Kummer FJ, Bharam S, Chen D, Halder S (1996).Distal femoral fixation: a laboratory comparison of the 95 de-grees plate, antegrade and retrograde inserted reamed intramed-ullary nails. J Orthop Trauma 10: 378–382

6. Meyer RW, Plaxton NA, Postak PD, Gilmore A, Froimson MI,Greenwald AS (2000) Mechanical comparison of a distal femo-ral side plate and a retrograde intramedullary nail. J OrthopTrauma 14: 398–404

7. Tournetta P III, Tiburzi D (1994) Anterograde interlocked nail-ing of distal femoral fractures after gunshot wounds. J OrthopTrauma 8: 220–227

373

show healed radiographs and clinical flexion of one ofour patients.

Discussion

The fixation of complex distal femoral fractures is tech-nically difficult. Surgeons with less experience andtraining in fracture care presently are prompted to placea retractor medially secondary to difficulties with expo-sure and reduction; in our opinion, this results in moreuncontrolled dissection than intended. Double platingvia the anterior approach provides excellent visualiza-tion and permits controlled access to the distal femurwhile minimizing any inadvertent stripping of the medi-al side. The ability to supplement a lateral plate with ananterior plate increases structural stability in the form ofa 90–90 construct. Similar to its application in fixationof the distal humerus, this construct resists deformationin both sagittal and coronal planes. Use of the recon-struction plate was discontinued early in the series, andat present, the preferred anterior plate is a 3.5 mm DCplate, especially with longer fracture planes. The au-thors acknowledge the increased amount of acute graft-ing, but in many of these severe fractures there was sig-nificant bone loss or comminution. The abundant avail-

Fig. 9 Clinical result at 12 months. Full weight bearing withoutpain was possible. Active flexion greater than 120°