24
Pressure Booster System KSB Delta Solo KSB Delta Solo MVP KSB Delta Solo SVP Type Series Booklet

KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

  • Upload
    others

  • View
    106

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Pressure Booster System

KSB Delta Solo

KSB Delta Solo MVPKSB Delta Solo SVP

Type Series Booklet

Page 2: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Legal information/Copyright

Type Series Booklet KSB Delta Solo

All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,edited or processed for any other purpose, nor otherwise transmitted, published or made available to athird party without the manufacturer's express written consent.

Subject to technical modification without prior notice.

© KSB B.V., Alphen aan den Rijn, Nederland 30/10/2018

Page 3: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Contents

Building Services: Water Supply ......................................................................................................................  4Pressure Booster Systems...........................................................................................................................................................  4

KSB Delta Solo......................................................................................................................................................................  4Main applications...........................................................................................................................................................  4Fluids handled ................................................................................................................................................................  4Operating data...............................................................................................................................................................  4Design details .................................................................................................................................................................  4Designation ....................................................................................................................................................................  5Configuration and function ..........................................................................................................................................  6Materials .........................................................................................................................................................................  6Product benefits .............................................................................................................................................................  7Certifications ..................................................................................................................................................................  8Selection information ....................................................................................................................................................  8Technical data ................................................................................................................................................................  8

KSB Delta Solo MVP .................................................................................................................................................  8KSB Delta Solo SVP...................................................................................................................................................  9

Characteristic curves.....................................................................................................................................................  10KSB Delta Solo, MVP, pump size 02, n = 2900 rpm..............................................................................................  10KSB Delta Solo, MVP, pump size 04, n = 2900 rpm..............................................................................................  11KSB Delta Solo, MVP, pump size 06, n = 2900 rpm..............................................................................................  12KSB Delta Solo, MVP, pump size 10, n = 2900 rpm..............................................................................................  13KSB Delta Solo, SVP, pump size 02, n = 2900 rpm................................................................................................  14KSB Delta Solo, SVP, pump size 04, n = 2900 rpm................................................................................................  15KSB Delta Solo, SVP, pump size 06, n = 2900 rpm................................................................................................  16KSB Delta Solo, SVP, pump size 10, n = 2900 rpm................................................................................................  17KSB Delta Solo, SVP, pump size 15, n = 2900 rpm................................................................................................  18

Dimensions and connections .......................................................................................................................................  19KSB Delta Solo MVP ...............................................................................................................................................  19KSB Delta Solo SVP.................................................................................................................................................  20

General assembly drawings/exploded views with list of components......................................................................  21KSB Delta Solo MVP ...............................................................................................................................................  21KSB Delta Solo SVP.................................................................................................................................................  22

Contents

3

Page 4: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

4 KSB Delta Solo

Building Services: Water Supply

Pressure Booster Systems

KSB Delta Solo

Main applications▪ Pressure boosting

Fluids handled▪ Drinking water

▪ Service water

▪ Cooling water

▪ Fluids not chemically or mechanically aggressive to thematerials

Operating data

Operating properties

Characteristic Value

Flow rate Q [m3/h] ≤ 21,8Q [l/s] ≤ 6,1

Head H [m] ≤ 134Fluid temperature Tmin. [°C] ≥ 0

Tmax. [°C] ≤ +60Operating pressure p [bar] ≤ 16Inlet pressure pinl [bar] ≤ 41)

Design details

Design▪ Fully automatic pressure booster package system

▪ Variable speed operation

▪ Baseplate-mounted

▪ Vertical high-pressure centrifugal pump

▪ Hydraulic components made of stainless steel / brass forhigh operating reliability

▪ Lift check valve for each pump

▪ Shut-off valve for each pump

▪ Membrane-type accumulator on the discharge side,approved for drinking water

▪ Pressure gauge for pressure indication

▪ Electronic dry running protection

▪ Pressure transmitter on the discharge side

▪ Anti-vibration pads per pump

Installation▪ Stationary dry installation

Drive▪ Electric motor

▪ Enclosure IP55

MVP

▪ Efficiency class IE3 to IEC 60034-30

SVP

▪ Efficiency class IE5 to IEC 60034-30

Automation▪ One frequency inverter per pump

SVP

▪ Display on each drive

▪ Fault message signalling contact per pump

▪ Operation signalling contact per pump

1) For higher inlet pressures contact the manufacturer.

Page 5: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

5KSB Delta Solo

Designation

Designation example

Position

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22

K D C M V P 2 - 0 0 2 / 1 4 0 M 5 A 0 1 0

K D S M V P 1 - 0 0 4 / 1 2 0 M 5 S 3 1

K D E S V P 2 - 0 1 0 / 1 1 0 M 5 A 1 1

K D P - V P 3 - 0 1 5 / 0 8 0 M 5 S 3 1

See data sheet

Designation key

Position Code Description

1-3 Type seriesKDC KSB Delta CompactKDS KSB Delta SoloKDE KSB Delta EcoKDP KSB Delta Primo

5-7 Design-K- Fixed speed pressure booster system-VP Variable speed pressure booster system, frequency inverter in the control

cabinetMVP Variable speed pressure booster system, frequency inverter mounted on

the motorSVP Variable speed pressure booster system with KSB SuPremE motor and

frequency inverter mounted on the motor8 Number of pumps

1 1 pump2 2 pumps3 3 pumps

10-12 Pump size002 Pump size 2004 Pump size 4006 Pump size 6010 Pump size 10015 Pump size 15C02 Comeo 2C04 Comeo 3C06 Comeo 4

14-15 Number of pump stages01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 14

16 Impeller design0 No trimmed impeller1 1 trimmed impeller2 2 trimmed impellersL Impeller for low NPSH valueR 1 trimmed impeller + version LS 2 trimmed impellers + version L

17 Inlet conditionsM Inlet side of pressure booster system connected to the municipal water

supplyF Pressure booster system takes in water from a break tank arranged on

same level as pumpL Pressure booster system takes in water from a break tank arranged at a

lower levelR Pressure booster system takes in water from a break tank arranged on

same level as pump; level-controlled intake18 Frequency [Hz]

5 50 Hz6 60 Hz

19 DriveA Asynchronous motor (IEC), standard

Page 6: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

6 KSB Delta Solo

Position Code Description

19 S KSB SuPremE20 Frequency inverter design

0 Fixed speed1 Nastec Mida2 Mididrive (FC280)3 PumpDrive Eco4 PumpDrive 25 Aquadrive(FC202)6 Without control panel

21 Control system design0 In the frequency inverter1 Central control system2 Without control panel

22 Dry running protection (RDP) design0 NO contacts2)

1 Pressure switch2 Pressure transmitter3 Cos phi4 NO contacts3)

Configuration and function

1

2

6

4

5

12

3

6

4

5

3

Fig. 1: Illustration of KSB Delta Solo

1 Frequency inverter 2 Accumulator3 Pump 4 Pressure gauge5 Connection 6 Baseplate

DesignThe fully automatic pressure booster system pumps the fluid tothe consumer installations in the set pressure range with anon-self-priming vertical high-pressure pump (3).

FunctionThe pressure booster system is started and stoppedautomatically as a function of pressure. The pump is started upas a function of pressure when consumer installations areopened. Lack of water will cause the frequency inverter to stopthe pump automatically.

In manual mode, a minimum flow is essential to prevent thefluid handled and/or the pump from overheating when nowater is consumed at the consumer installations.

Materials

Overview of available materials

Component Material

Pump casing 1.4308Pump shroud 1.4301Hydraulic system 1.4301Mechanical seal To EN 12756Elastomer EPDMBaseplate Steel, powder-coatedShut-off valve Brass, nickel-coatedSwing check valve POMAccumulator, connection 1.4401Membrane Approved for drinking water

2) External dry running protection device supplied by the customer: pump running at closed contact, low-load detection (cosphi) enabled

3) External dry running protection device supplied by the customer: contact in control unit

Page 7: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

7KSB Delta Solo

Product benefits▪ Energy-efficient operation and constant pressure ensured

by speed control of all pumps.

▪ Suitable for drinking water; manufactured under stringenthygienic conditions

▪ Easy and fast commissioning of ready-to-connect, pre-assembled and tested system

▪ Corrosion resistance provided by powder-coated materialsand stainless steel

▪ Integral dry running protection for reliable operation

Page 8: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

8 KSB Delta Solo

Certifications

Overview

Label Effective in: Comment

France Approved in accordance with theFrench drinking water regulation

UnitedKingdom

Approved in accordance with the UKdrinking water regulation

Globe valves and swing check valve:Germany Approved in accordance with the

German drinking water regulation

Selection information

Selection exampleRequirements:Specified duty point at:

▪ Flow rate: 10 m³/h

▪ Head: 60 m

▪ Inlet pressure: 1 bar

Solution:1. Subtract the inlet pressure of 1 bar (approx. 10 m) from

the head.

ð This results in a required head of 40 m.

2. Transfer the values to the characteristic curves diagramto select the corresponding pump.

ð This results in the selection of a KSB Delta Solo SVP 10/06.

Technical data

KSB Delta Solo MVPMVP = variable speed pressure booster system

1 × 230 V ± 10 %

Dry running protection = switch

50 Hz

KSB Delta Solo

Nu

mb

er o

f p

um

ps

Size

Nu

mb

er o

f st

ages

P N

Mo

tor

effi

cien

cycl

ass I N

I A/I

N Freq

uen

cy o

fst

arts

I max

Sys

tem

I max

Ove

rcu

rren

t

pro

tect

ion

Sou

nd

pre

ssu

rele

vel

Encl

osu

re

p

PN [kg

]

Mat

. No

.

[kW] [A] [x/h] [A] [A] [dB(A)] [bar]

MVP 1 02 05 0,37 IE - 1,6 - 50 4,5 - 60 IP55 5 10 31 48278796MVP 1 02 08 0,55 IE - 2,1 - 50 4,5 - 60 IP55 5 16 32 48278797MVP 1 02 10 0,75 IE3 3,1 - 50 7,5 - 55 IP55 5 16 39 48278798MVP 1 02 14 1,10 IE3 4 - 50 7,5 - 55 IP55 5 16 41 48278799

MVP 1 04 02 0,37 IE - 1,6 - 50 4,5 - 60 IP55 5 10 30 48278800MVP 1 04 04 0,55 IE - 2,1 - 50 4,5 - 60 IP55 5 16 32 48278801MVP 1 04 05 0,75 IE3 3,1 - 50 7,5 - 55 IP55 5 10 37 48278802MVP 1 04 07 1,10 IE3 4 - 50 7,5 - 55 IP55 5 16 38 48278803MVP 1 04 10 1,50 IE3 5,3 - 50 11 - 55 IP55 5 16 45 48278804

MVP 1 06 02 0,37 IE - 1,6 - 50 4,5 - 60 IP55 5 10 30 48278805MVP 1 06 03 0,75 IE3 3,1 - 50 7,5 - 55 IP55 5 10 37 48278806MVP 1 06 05 1,10 IE3 4 - 50 7,5 - 55 IP55 5 10 38 48278807MVP 1 06 07 1,50 IE3 5,3 - 50 11 - 55 IP55 5 16 44 48278808MVP 1 06 10 2,20 IE3 7,5 - 30 11 - 55 IP55 5 16 47 48278809

MVP 1 10 02 0,37 IE3 3,1 - 50 7,5 - 55 IP55 5 10 48 48278810MVP 1 10 03 0,75 IE3 4 - 50 7,5 - 55 IP55 5 10 51 48278811MVP 1 10 04 1,10 IE3 5,3 - 50 11 - 55 IP55 5 10 56 48278812

Page 9: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

9KSB Delta Solo

KSB Delta Solo SVPSVP = variable speed pressure booster system with KSB SuPremE motor

3 × 400 V ± 10 %

Dry running protection = sensor

50 Hz

KSB Delta Solo

Nu

mb

er o

f p

um

ps

Size

Nu

mb

er o

f st

ages

P N

Mo

tor

effi

cien

cycl

ass I N

I A/I

N Freq

uen

cy o

fst

arts

I max

Sys

tem

I max

Ove

rcu

rren

t

pro

tect

ion

Sou

nd

pre

ssu

rele

vel

Encl

osu

re

p

PN [kg

]

Mat

. No

.

[kW] [A] [x/h] [A] [A] [dB(A)] [bar]

SVP 1 02 05 0,37 IE5 1,3 - - 1,4 - 70 IP55 5 10 34 48278813SVP 1 02 08 0,55 IE5 1,6 - - 2 - 70 IP55 5 16 34 48278814SVP 1 02 10 0,75 IE5 2,1 - - 2,7 - 70 IP55 5 16 41 48278815SVP 1 02 14 1,10 IE5 3 - - 3,7 - 70 IP55 5 16 43 48278816

SVP 1 04 02 0,37 IE5 1,3 - - 1,4 - 70 IP55 5 10 33 48278817SVP 1 04 04 0,55 IE5 1,6 - - 2 - 70 IP55 5 10 33 48278818SVP 1 04 05 0,75 IE5 2,1 - - 2,7 - 70 IP55 5 10 39 48278819SVP 1 04 07 1,10 IE5 3 - - 3,7 - 70 IP55 5 16 40 48278820SVP 1 04 10 1,50 IE5 4,1 - - 5,2 - 70 IP55 5 16 44 48278821SVP 1 04 14 2,20 IE3 5,6 - - 6,3 - 70 IP55 3,5 16 48 48278822

SVP 1 06 02 0,37 IE5 1,3 - - 1,4 - 70 IP55 5 10 33 48278823SVP 1 06 03 0,75 IE5 2,1 - - 2,7 - 70 IP55 5 10 39 48278824SVP 1 06 05 1,10 IE5 3 - - 3,7 - 70 IP55 5 10 40 48278825SVP 1 06 07 1,50 IE5 4,1 - - 5,2 - 70 IP55 5 16 43 48278826SVP 1 06 10 2,20 IE5 5,6 - - 6,3 - 70 IP55 5 16 47 48278827SVP 1 06 14 3,00 IE5 7,6 - - 8,4 - 71 IP55 2,5 16 58 48278828

SVP 1 10 02 0,75 IE5 2,1 - - 2,7 - 70 IP55 5 10 50 48278829SVP 1 10 03 1,10 IE5 3 - - 3,7 - 70 IP55 5 10 52 48278830SVP 1 10 04 1,50 IE5 4,1 - - 5,2 - 70 IP55 5 10 54 48278831SVP 1 10 06 2,20 IE5 5,6 - - 6,3 - 70 IP55 5 16 60 48278832SVP 1 10 08 3,00 IE5 7,6 - - 8,4 - 71 IP55 5 16 69 48278833SVP 1 10 11 4,00 IE5 9,4 - - 10,4 - 71 IP55 3,5 16 85 48278834

SVP 1 15 02 2,20 IE5 5,6 - - 6,3 - 70 IP55 5 10 56 48278835SVP 1 15 03 3,00 IE5 7,6 - - 8,4 - 71 IP55 5 10 64 48278836SVP 1 15 04 4,00 IE5 9,4 - - 10,4 - 71 IP55 5 16 77 48278837SVP 1 15 06 5,50 IE5 12,5 - - 14,6 - 71 IP55 5 16 83 48278838SVP 1 15 08 7,50 IE5 16,7 - - 18,7 - 71 IP55 4,5 16 83 48278839

Page 10: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

10 KSB Delta Solo

Characteristic curves

KSB Delta Solo, MVP, pump size 02, n = 2900 rpm

KDS-MVP-02_50Hz/0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5Q [m³/h]

0 5 10 15Q [US.gpm]

0 2 4 6 8 10 12Q [IM.gpm]

0

20

40

60

80

100

120

H [m]

0

100

200

300

H [ft]

0.0 0.2 0.4 0.6 0.8 1.0Q [l/s]

0

8

NPSH3 [m]

0

20NPSH3 [ft]

0

60

Eta [%]

0.05

0.02

0.08P [kW]

0.1

0.04

P [hp]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5Q [m³/h]

2/14 1,1kW

2/10 0,75kW

2/08 0,55kW

2/05 0,37kW

St=1

St = 1 P per stage

Page 11: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

11KSB Delta Solo

KSB Delta Solo, MVP, pump size 04, n = 2900 rpm

KDS-MVP-04_50Hz/0

0 1 2 3 4 5 6 7Q [m³/h]

0 10 20 30Q [US.gpm]

0 5 10 15 20 25Q [IM.gpm]

0

20

40

60

80

H [m]

0

100

200

300

H [ft]

0.0 0.5 1.0 1.5Q [l/s]

0

5

NPSH3 [m]

0

15

NPSH3 [ft]

0

80

Eta [%]

0.0

0.15

P [kW]

0.0

0.2

P [hp]

0 1 2 3 4 5 6 7Q [m³/h]

4/10 1,5kW

4/07 1,1kW

4/05 0,75kW

4/04 0,55kW

4/02 0,37kW

St=1

St = 1 P per stage

Page 12: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

12 KSB Delta Solo

KSB Delta Solo, MVP, pump size 06, n = 2900 rpm

KDS-MVP-06_50Hz/0

0 2 4 6 8 10Q [m³/h]

0 10 20 30 40Q [US.gpm]

0 10 20 30Q [IM.gpm]

0

20

40

60

80

100

H [m]

0

100

200

300

H [ft]

0.0 0.5 1.0 1.5 2.0 2.5Q [l/s]

0

4

NPSH3 [m]

0

10NPSH3 [ft]

0

80

Eta [%]

0.2

0.05

P [kW]

0.1

0.3

P [hp]

0 2 4 6 8 10Q [m³/h]

6/10 2,2kW

6/07 1,5kW

6/05 1,1kW

6/03 0,75kW

6/02 0,37kW

St=1

St = 1 P per stage

Page 13: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

13KSB Delta Solo

KSB Delta Solo, MVP, pump size 10, n = 2900 rpm

KDS-MVP-10_50Hz/0

0 2 4 6 8 10 12 14Q [m³/h]

0 20 40 60Q [US.gpm]

0 10 20 30 40 50Q [IM.gpm]

10

20

30

40

H [m]

20

40

60

80

100

120

140

H [ft]

0 1 2 3 4Q [l/s]

0

6

NPSH3 [m]

0

10NPSH3 [ft]

0

80

Eta [%]

0.0

0.5

P [kW]

0

0.6

P [hp]

0 2 4 6 8 10 12 14Q [m³/h]

10/04 1,5kW

10/03 1,1kW

10/02 0,75kW

St=1

St = 1 P per stage

Page 14: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

14 KSB Delta Solo

KSB Delta Solo, SVP, pump size 02, n = 2900 rpm

KDS-SVP-02_50Hz/0

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5Q [m³/h]

0 5 10 15Q [US.gpm]

0 2 4 6 8 10 12Q [IM.gpm]

0

20

40

60

80

100

120

H [m]

0

100

200

300

H [ft]

0.0 0.2 0.4 0.6 0.8 1.0Q [l/s]

0

8

NPSH3 [m]

0

20NPSH3 [ft]

0

60

Eta [%]

0.05

0.02

0.08P [kW]

0.1

0.04

P [hp]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5Q [m³/h]

2/14 1,1kW

2/10 0,75kW

2/08 0,55kW

2/05 0,37kW

St=1

St = 1 P per stage

Page 15: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

15KSB Delta Solo

KSB Delta Solo, SVP, pump size 04, n = 2900 rpm

KDS-SVP-04_50Hz/0

0 1 2 3 4 5 6 7Q [m³/h]

0 10 20 30Q [US.gpm]

0 5 10 15 20 25Q [IM.gpm]

0

20

40

60

80

100

120

H [m]

0

100

200

300

400

H [ft]

0.0 0.5 1.0 1.5Q [l/s]

0

5

NPSH3 [m]

0

15

NPSH3 [ft]

0

80

Eta [%]

0.0

0.15

P [kW]

0.0

0.2

P [hp]

0 1 2 3 4 5 6 7Q [m³/h]

4/14 2,2kW

4/10 1,5kW

4/07 1,1kW

4/05 0,75kW

4/04 0,55kW

4/02 0,37kW

St=1

St = 1 P per stage

Page 16: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

16 KSB Delta Solo

KSB Delta Solo, SVP, pump size 06, n = 2900 rpm

KDS-SVP-06_50Hz/0

0 2 4 6 8 10Q [m³/h]

0 10 20 30 40Q [US.gpm]

0 10 20 30Q [IM.gpm]

0

20

40

60

80

100

120

140

H [m]

0

100

200

300

400

H [ft]

0.0 0.5 1.0 1.5 2.0 2.5Q [l/s]

0

4

NPSH3 [m]

0

10NPSH3 [ft]

0

80

Eta [%]

0.2

0.05

P [kW]

0.1

0.3

P [hp]

0 2 4 6 8 10Q [m³/h]

6/14 3,0kW

6/10 2,2kW

6/07 1,5kW

6/05 1,1kW

6/03 0,75kW

6/02 0,37kW

St=1

St = 1 P per stage

Page 17: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

17KSB Delta Solo

KSB Delta Solo, SVP, pump size 10, n = 2900 rpm

KDS-SVP-10_50Hz/0

0 2 4 6 8 10 12 14Q [m³/h]

0 20 40 60Q [US.gpm]

0 10 20 30 40 50Q [IM.gpm]

0

20

40

60

80

100

120

H [m]

0

100

200

300

400

H [ft]

0 1 2 3 4Q [l/s]

0

6

NPSH3 [m]

0

10NPSH3 [ft]

0

80

Eta [%]

0.0

0.5

P [kW]

0

0.6

P [hp]

0 2 4 6 8 10 12 14Q [m³/h]

10/11 4,0kW

10/08 3,0kW

10/06 2,2kW

10/04 1,5kW

10/03 1,1kW

10/02 0,75kW

St=1

St = 1 P per stage

Page 18: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

18 KSB Delta Solo

KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

KDS-SVP-15_50Hz/0

0 5 10 15 20Q [m³/h]

0 20 40 60 80 100Q [US.gpm]

0 20 40 60 80Q [IM.gpm]

0

20

40

60

80

100

120

H [m]

0

100

200

300

400

H [ft]

0 2 4 6Q [l/s]

0

4

NPSH3 [m]

0

10NPSH3 [ft]

0

80

Eta [%]

0

1

P [kW]

0

1P [hp]

0 5 10 15 20Q [m³/h]

15/08 7,5kW

15/06 5,5kW

15/04 4,0kW

15/03 3,0kW

15/02 2,2kW

St=1

St = 1 P per stage

Page 19: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

19KSB Delta Solo

Dimensions and connections

KSB Delta Solo MVP

H2

Lt

W2W1Wt

L1

L4

Ht

L5L3L2

H1

DN1DN2

Fig. 2: Dimensions

① Switch

Dimensions [mm] and connections

Nu

mb

er o

fp

um

ps

Size

Nu

mb

er o

fst

ages

DN1 DN2 L1 L2 L3 L4 L5 Lt H1 H2 Ht W1 W2 Wt

1 02 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 587 170 193 3631 02 08 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 686 170 193 3631 02 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 720 170 207 3771 02 14 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 836 170 207 377

1 04 02 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 523 170 193 3631 04 04 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 590 170 193 3631 04 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 612 170 207 3771 04 07 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 685 170 207 3771 04 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 777 170 222 392

1 06 02 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 530 170 193 3631 06 03 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 580 170 207 3771 06 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 660 170 207 3771 06 07 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 737 170 222 3921 06 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 837 170 222 392

1 10 02 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 625 190 207 3971 10 03 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 681 190 207 3971 10 04 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 735 190 222 412

Page 20: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

20 KSB Delta Solo

KSB Delta Solo SVPHt

W1 W2Wt

H2 L1

L4L2 L3

L5Lt

H1

DN2DN1

Fig. 3: Dimensions

① Sensor (dry running protection)

Dimensions [mm] and connections

Nu

mb

er o

fp

um

ps

Size

Nu

mb

er o

fst

ages

DN1 DN2 L1 L2 L3 L4 L5 Lt H1 H2 Ht W1 W2 Wt

1 02 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 643 170 220 3901 02 08 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 718 170 220 3901 02 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 761 170 235 4051 02 14 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 847 170 235 405

1 04 02 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 579 170 220 3901 04 04 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 622 170 220 3901 04 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 653 170 235 4051 04 07 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 698 170 235 4051 04 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 783 170 240 4101 04 14 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 893 170 230 400

1 06 02 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 586 170 220 3901 06 03 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 621 170 235 4051 06 05 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 671 170 235 4051 06 07 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 743 170 240 4101 06 10 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 842 170 230 4001 06 14 G 1 1/4 G 1 1/4 260 102 340 130 268 503 95 28 982 170 240 410

1 10 02 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 666 190 235 4251 10 03 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 692 190 235 4251 10 04 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 741 190 240 4301 10 06 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 818 190 230 4201 10 08 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 911 190 240 4301 10 11 G 1 1/2 G 1 1/2 340 129 379 170 309 584 125 28 1011 190 255 445

1 15 02 G 2 G 2 340 129 379 170 309 584 125 28 688 190 230 4201 15 03 G 2 G 2 340 129 379 170 309 584 125 28 778 190 240 4301 15 04 G 2 G 2 340 129 379 170 309 584 125 28 826 190 255 4451 15 06 G 2 G 2 340 129 379 170 309 584 125 28 981 190 310 5001 15 08 G 2 G 2 340 129 379 170 309 584 125 28 1093 190 330 520

Page 21: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

21KSB Delta Solo

General assembly drawings/exploded views with list of components

KSB Delta Solo MVP

595

655

742.01

742.02

79-2

743.90

591

691

838

Fig. 4: KSB Delta Eco MVP

List of components

Part No. Description Part No. Description

79-2 Measuring transducer 691 Pressure gauge591 Accumulator 742.01/.02 Check valve595 Anti-vibration pad 743.90 Ball/plug valve655 Pump 838 Switch

The individual parts of the pump set are shown in the product literature of the pump set.

Page 22: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

Building Services: Water SupplyPressure Booster Systems

22 KSB Delta Solo

KSB Delta Solo SVP

595

655

742.01

742.02

591

79-2

743.90

691

79-2

Fig. 5: KSB Delta Eco SVP

List of components

Part No. Description Part No. Description

79-2 Measuring transducer 691 Pressure gauge591 Accumulator 742.01/.02 Check valve595 Anti-vibration pad 743.90 Ball/plug valve655 Pump

The individual parts of the pump set are shown in the product literature of the pump set.

Page 23: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm
Page 24: KSB Delta Solo - ProIdea · KSB Delta Solo, SVP, pump size 06, n = 2900 rpm 16. KSB Delta Solo, SVP, pump size 10, n = 2900 rpm 17. KSB Delta Solo, SVP, pump size 15, n = 2900 rpm

KSB SE & Co. KGaAJohann-Klein-Straße 9 • 67227 Frankenthal (Germany)Tel. +49 6233 86-0www.ksb.com

1983

.521

/01-

EN30

/10/

2018