75
INDEX SHEET 1 DETAIL #: RELEASE: XX-XX-XX-KSV KS SERIES - VERTICAL INSTALLATION CI-DS-01-KSV C & I DISCLAIMER CI-PP-01-KSV PANEL PROFILES CI-PP-02-KSV PANEL PROFILES CI-FP-01-KSV FASTENING PATTERNS CI-FP-02-KSV FASTENING PATTERNS CI-FP-03-KSV FASTENING PATTERNS CI-PJ-01-KSV EXPANDED PANEL JOINT CI-PJ-02-KSV ENGAGED PANEL JOINT CI-PJ-03-KSV INTERMEDIATE SUPPORT CI-BS-01-KSV FLUSH BASE CI-BS-02-KSV FLUSH BASE 2 CI-BS-03-KSV BASE AT NOTCHED CONCRETE CI-BS-04-KSV OVERHANG WITH BASE SUPPORT CI-BS-05-KSV OVERHANG WITH BASE ANGLE CI-BS-06-KSV OVERHANG W/ BASE "J" EXTRUSION CI-BS-07-KSV BASE DETAIL MARRIAGE BEAD ISOMETRIC CI-OC-01-KSV OUTSIDE CORNER WITH PROFILED TRIM CI-OC-02-KSV OUTSIDE CORNER WITH FLAT TRIM CI-OC-03-KSV OUTSIDE CORNER WITH EXTRUSION CI-IC-01-KSV INSIDE CORNER WITH PROFILED TRIM CI-IC-02-KSV INSIDE CORNER WITH FLAT TRIM CI-IC-03-KSV INSIDE CORNER WITH EXTRUSION CI-IC-04-KSV TRIM LAP AT I.C. BASE EXPANDED CI-IC-05-KSV TRIM LAP AT I.C. BASE ENGAGED CI-IC-06-KSV INSIDE CORNER TRIM LAP EXPANDED CI-IC-07-KSV INSIDE CORNER TRIM LAP ENGAGED CI-FO-01-KSV F.O. TWO PIECE HEAD CI-FO-02-KSV F.O. HEAD WITH DRIP EDGE CI-FO-03-KSV F.O. TWO PIECE JAMB CI-FO-04-KSV F.O. ONE PIECE JAMB CI-FO-05-KSV F.O. ONE PIECE SILL CI-FO-06-KSV F.O. INTERIOR PARTITION CI-FO-07-KSV O.H. DOOR TWO PIECE HEAD 2021 REVISION 0 1/01/21 1 1/27/21 2 2/03/21 3 3/03/21 4 8/10/21 5 11/30/21 www.kingspanpanels.com

KS SERIES - VERTICAL INSTALLATION

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

INDEX SHEET 1DETAIL #:

RELEASE:

XX-XX-XX-KSV

KS SERIES - VERTICAL INSTALLATIONCI-DS-01-KSV C & I DISCLAIMERCI-PP-01-KSV PANEL PROFILESCI-PP-02-KSV PANEL PROFILESCI-FP-01-KSV FASTENING PATTERNSCI-FP-02-KSV FASTENING PATTERNSCI-FP-03-KSV FASTENING PATTERNSCI-PJ-01-KSV EXPANDED PANEL JOINTCI-PJ-02-KSV ENGAGED PANEL JOINTCI-PJ-03-KSV INTERMEDIATE SUPPORTCI-BS-01-KSV FLUSH BASECI-BS-02-KSV FLUSH BASE 2CI-BS-03-KSV BASE AT NOTCHED CONCRETECI-BS-04-KSV OVERHANG WITH BASE SUPPORTCI-BS-05-KSV OVERHANG WITH BASE ANGLECI-BS-06-KSV OVERHANG W/ BASE "J" EXTRUSIONCI-BS-07-KSV BASE DETAIL MARRIAGE BEAD ISOMETRICCI-OC-01-KSV OUTSIDE CORNER WITH PROFILED TRIMCI-OC-02-KSV OUTSIDE CORNER WITH FLAT TRIMCI-OC-03-KSV OUTSIDE CORNER WITH EXTRUSIONCI-IC-01-KSV INSIDE CORNER WITH PROFILED TRIMCI-IC-02-KSV INSIDE CORNER WITH FLAT TRIMCI-IC-03-KSV INSIDE CORNER WITH EXTRUSIONCI-IC-04-KSV TRIM LAP AT I.C. BASE EXPANDEDCI-IC-05-KSV TRIM LAP AT I.C. BASE ENGAGEDCI-IC-06-KSV INSIDE CORNER TRIM LAP EXPANDEDCI-IC-07-KSV INSIDE CORNER TRIM LAP ENGAGEDCI-FO-01-KSV F.O. TWO PIECE HEADCI-FO-02-KSV F.O. HEAD WITH DRIP EDGECI-FO-03-KSV F.O. TWO PIECE JAMBCI-FO-04-KSV F.O. ONE PIECE JAMBCI-FO-05-KSV F.O. ONE PIECE SILLCI-FO-06-KSV F.O. INTERIOR PARTITIONCI-FO-07-KSV O.H. DOOR TWO PIECE HEAD

2021

REVISION0 1/01/211 1/27/212 2/03/213 3/03/214 8/10/215 11/30/21

www.kingspanpanels.com

INDEX SHEET 2DETAIL #:

RELEASE:

XX-XX-XX-KSV

2021

KS SERIES - VERTICAL INSTALLATION

CI-FO-08-KSV O.H. DOOR HEAD WITH DRIP EDGECI-FO-9-KSV O.H. DOOR TWO PIECE JAMBCI-FO-10-KSV HEADER WITH EXTRUSIONCI-FO-11-KSV JAMB WITH EXTRUSIONCI-FO-12-KSV SILL WITH EXTRUSIONCI-FO-13-KSV O.H. DOOR WITH EXTRUSIONCI-FO-14-KSV O.H. DOOR JAMB WITH EXTRUSIONCI-SJ-01-KSV STACK JOINTCI-SJ-02-KSV STACK JOINT WITH EXTRUSIONCI-PR-01-KSV PARAPET WITH FLUSH TRIMCI-PR-02-KSV PARAPET WITH PROFILED TRIMCI-SO-01-KSV WALL ABOVE TO HORIZONTAL SOFFITCI-SO-02-KSV WALL BELOW TO HORIZONTAL SOFFITCI-SO-03-KSV WALL ABOVE TO VERTICAL SOFFITCI-SO-04-KSV WALL BELOW TO VERTICAL SOFFITCI-WR-01-KSV WALL TO ROOFCI-WR-02-KSV CONTINUOUS WALL TO ROOF / CANOPYCI-PE-01-KSV PIPE PENETRATIONCI-PE-02-KSV PIPE PENETRATION ISOMETRICCI-PE-03-KSV KNIFE PENETRATIONCI-PE-04-KSV KNIFE PENETRATION ISOMETRICCI-PE-05-KSV BEAM PENETRATIONCI-PE-06-KSV BEAM PENETRATION ISOMETRICCI-TL-01-KSV TRIM END LAPCI-TL-02-KSV TRIM END LAP WITH HEMCI-TL-03-KSV TRIM END LAP WITH LAP STRIPCI-TL-04-KSV TRIM LAP W/ FLEXWRAP AT F.O.CI-TL-05-KSV TRIM LAP AT F.O. INSTALLATIONCI-TL-06-KSV FLEXWRAP AT F.O. INSTALLATIONCI-TL-07-KSV 2" EXTRUSIONS

REVISIONREVISION # DATE

5 11/30/21

www.kingspanpanels.com

REVISIONREVISION # DATE

5 11/30/21

INDEX SHEET 3DETAIL #:

RELEASE:

XX-XX-XX-KSV

2021

KS SERIES - VERTICAL INSTALLATION

CI-TL-08-KSV 212" EXTRUSIONS

CI-TL-09-KSV 3" EXTRUSIONSCI-TL-10-KSV 4" EXTRUSIONSCI-TL-11-KSV EXTRUSION LAP STRIPSCI-TL-12-KSV EXTRUSION W/ FLEXWRAP AT F.O.CI-TL-13-KSV EXTRUSION W/ FLEXWRAP AT F.O.CI-TL-14-KSV TRIM LAP W/ FLEXWRAP AT REMOVABLE F.O.CI-TL-15-KSV EXTRUSION W/ FLEXWRAP AT REMOV. F.O.

www.kingspanpanels.com

COMMERCIAL/INDUSTRIALDISCLAIMER

DETAIL #:

RELEASE:

CI-DS-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

DISCLAIMERS:

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATEDCOMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASEDON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARYVAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).

PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAYREQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICESFOR SPECIFIC PROJECT RECOMMENDATIONS.

ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION ANDILLUSTRATION PURPOSES ONLY.

CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANSAND FASTENING PATTERNS.

REVISIONREVISION # DATE

0 01/01/21

www.kingspanpanels.com

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS SHADOWLINE (SL)

EXTERIOR FACE

INTERIOR FACESHADOWLINE

SHADOWLINE

MALE JOINT

FEMALE JOINT

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS MICRO RIB (MR)

EXTERIOR FACE

INTERIOR FACESHADOWLINE

MICRO-RIB

MALE JOINT

FEMALE JOINT

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS MINI-MICRO RIB (MMR)

EXTERIOR FACE

INTERIOR FACESHADOWLINE

MINI MICRO-RIB(*SMOOTH ONLY)

MALE JOINT

FEMALE JOINT

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS AZTECO (AZ)

EXTERIOR FACE

INTERIOR FACE

AZTECO

SHADOWLINE MALE JOINT

FEMALE JOINT

CORE DEPTHS:2", 2.5", 3", 4", 5", 6"

STEEL GAUGES:EXTERIOR: (REFER TO PROFILE)INTERIOR: 26, 24, 22

MODULE WIDTH: 24", 30", 36", 42"

PANEL ORIENTATION: VERTICAL

EMBOSSING:EXTERIOR: STUCCO / SMOOTH*INTERIOR: STUCCO / SMOOTHLENGTHS:MINIMUM: 8'-0"MAXIMUM: 53'-0"

OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

REVEAL

OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

(24GA, 22GA ONLY) REVEAL

(24GA ONLY)

(22GA, 24GA, 26GA)

OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

(24GA, 22GA ONLY)

REVISIONREVISION # DATE

0 01/01/21

PANEL PROFILESDETAIL #:

RELEASE:

CI-PP-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS MINI WAVE (MW)

EXTERIOR FACE

INTERIOR FACESHADOWLINE

MINI-WAVE

MALE JOINT

FEMALE JOINT

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS SL FLAT

EXTERIOR FACE

INTERIOR FACE

FLAT

SHADOWLINE

2" - 6"

42" COVERAGE (36", 30", & 24" OPTIONAL)

KS GRANITSTONE/QUARTZ (GS)

EXTERIOR FACE

INTERIOR FACE

GRANITSTONE / QUARTZ

SHADOWLINE

MALE JOINT

FEMALE JOINT

MALE JOINT

FEMALE JOINT

40" COVERAGE(24", 30", 36" OPTIONAL)

2" - 4"KS OPTIMO (OPE or OPS)

EXTERIOR FACE

INTERIOR FACE

FLAT

SHADOWLINE or FLAT

CORE DEPTHS:2", 2.5", 3", 4", 5", 6"

STEEL GAUGES:EXTERIOR: (REFER TO PROFILE)INTERIOR: 26, 24, 22

MODULE WIDTH: 24", 30", 36", 42"

PANEL ORIENTATION: VERTICAL

EMBOSSING:EXTERIOR: STUCCO / SMOOTH*INTERIOR: STUCCO / SMOOTHLENGTHS:MINIMUM: 8'-0"MAXIMUM: 53'-0"

(26GA, 24GA, 22GA)

(24GA, 22GA ONLY)

(24GA, 22GA ONLY)

OPTIONAL TRIMLESS ENDS

NOTE:MAX LENGTH:EMBOSSED: 32'-0"SMOOTH: 20'-0"

(22GA ONLY)

REVISIONREVISION # DATE

0 1/21/21

PANEL PROFILESDETAIL #:

RELEASE:

CI-PP-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

MALEEND

FEMALEEND

INTERIOR FACE

EXTERIOR FACE

42"

MALEEND

FEMALEEND

42"

10.5"

FASTENING PATTERN 1BSTANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEX

HEAD FASTENER WITHOUT WASHER

FASTENING PATTERN 2BSTANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEX

HEAD FASTENER WITHOUT WASHER / ADDITIONAL 14"-14 "LOW PROFILE"THROUGH FASTENER W/ 1 18" BONDED WASHER 10.5" FROM FEMALE JOINT

INTERIOR FACE

EXTERIOR FACE

STRUCTURAL SUPPORT(BY OTHERS)1

4" - 14 "LOW PROFILE"THROUGH FASTENER W/1 18" BONDED WASHER

STRUCTURAL SUPPORT(BY OTHERS)

REVISIONREVISION # DATE

0 01/01/21

FASTENING PATTERNSDETAIL #:

RELEASE:

CI-FP-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

STRUCTURAL SUPPORT(BY OTHERS)

MALEEND

FEMALEEND

42"

10.5"

FASTENING PATTERN 4BSTANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEXHEAD FASTENER WITHOUT WASHER / 3 ADDITIONAL 14"-14 "LOW PROFILE"

THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 10.5" FROMFEMALE JOINT

MALEEND

FEMALEEND

INTERIOR FACE

EXTERIOR FACE

42"

10.5"

FASTENING PATTERN 3BSTANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEXHEAD FASTENER WITHOUT WASHER / 2 ADDITIONAL 14"-14 "LOW PROFILE"

THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 10.5" FROMFEMALE JOINT

10.5"

10.5" 10.5"

INTERIOR FACE

EXTERIOR FACE

STRUCTURALSUPPORT(BY OTHERS)

14" - 14 "LOW PROFILE"

THROUGH FASTENER W/1 18" BONDED WASHER

14" - 14 "LOW PROFILE"

THROUGH FASTENER W/1 18" BONDED WASHER

REVISIONREVISION # DATE

0 01/01/21

FASTENING PATTERNSDETAIL #:

RELEASE:

CI-FP-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

MALEEND

FEMALEEND

42"

8.4"

FASTENING PATTERN 5BSTANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEXHEAD FASTENER WITHOUT WASHER / 4 ADDITIONAL 14"-14 "LOW PROFILE"

THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 8.4" FROMFEMALE JOINT

8.4" 8.4"

INTERIOR FACE

EXTERIOR FACE

STRUCTURALSUPPORT(BY OTHERS)

14" - 14 "LOW PROFILE"

THROUGH FASTENER W/1 18" BONDED WASHER

8.4"

REVISIONREVISION # DATE

0 01/01/21

FASTENING PATTERNSDETAIL #:

RELEASE:

CI-FP-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FEMALE JOINTMALE JOINT

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

CONTINUOUSBUTYL SEALANT

CONTINUOUSBUTYL SEALANT(OPTIONAL)

WALL PANEL INSTALLATION DIRECTION

REVISIONREVISION # DATE

0 01/01/21

EXPANDEDPANEL JOINT

DETAIL #:

RELEASE:

CI-PJ-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FEMALE JOINTMALE JOINT

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

CONTINUOUSBUTYL SEALANT

CONTINUOUSBUTYL SEALANT(OPTIONAL)

WALL PANEL INSTALLATION DIRECTION

18"

PANEL MODULE

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

REVISIONREVISION # DATE

0 01/01/21

ENGAGEDPANEL JOINT

DETAIL #:

RELEASE:

CI-PJ-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 HEX HEAD FASTENERS

WITHOUT WASHER

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

21 4" 34 "

STANDARD:12 GA. STAINLESS STEELTWO-HOLE HIDDEN FASTENER CLIP

1"

516" Ø

NOTE:CONTACT KINGSPAN TECHNICAL SERVICESFOR SPECIFIC PROJECT RECOMMENDATIONS

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

INTERMEDIATESUPPORT

DETAIL #:

RELEASE:

CI-PJ-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

BASE TRIM W/ POPRIVETS @ 8" O.C.

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

FASTENER TO CONCRETE(NOT BY KINGSPAN)

BASE FLASHING

CONTINUOUS BUTYLSEALANT BELOW BASEFLASHING

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO VERTICALPANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT 1

4" - 14 HEX HEADFASTENERS WITHOUT WASHER

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

FLUSH BASEDETAIL #:

RELEASE:

CI-BS-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

BASE TRIM W/ POPRIVETS @ 8" O.C.

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

FASTENER TO CONCRETE(NOT BY KINGSPAN)

BASE FLASHING

CONTINUOUS BUTYLSEALANT BELOW BASEFLASHING

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO VERTICALPANEL JOINT

FLUSH BASE 2DETAIL #:

RELEASE:

CI-BS-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FASTENER TO CONCRETE(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT

CONTINUOUS BUTYL SEALANT W/MARRIAGE BEAD TO VERTICALPANEL JOINT

BASE FLASHING

CONTINUOUS BUTYLSEALANT BELOW BASEFLASHING

112"

(TYP

.)

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

BASE TRIM W/ POPRIVETS @ 8" O.C.

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-BS-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

BASE AT NOTCHEDCONCRETE

www.kingspanpanels.com

FASTENER TO CONCRETE(NOT BY KINGSPAN)

BASE TRIM

POP RIVETS@ 8" O.C.

112"

(TYP

.)

CONTINUOUS BUTYL SEALANT W/MARRIAGE BEAD TO VERTICALPANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-BS-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

OVERHANG WITHBASE SUPPORT

www.kingspanpanels.com

FASTENER TO CONCRETE(NOT BY KINGSPAN)

BASE TRIM W/POP RIVETS @8" O.C.

112"

(TYP

.)

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TO VERTICALPANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-BS-05-KSV

2021

KS SERIES - VERTICAL INSTALLATION

OVERHANG WITHBASE ANGLE

www.kingspanpanels.com

PANEL BASE "B"EXTRUSION

FASTENER TO CONCRETE(NOT BY KINGSPAN)

112"

(TYP

.)

CONTINUOUS BUTYL SEALANT BOTHSIDES OF EXTRUSION W/ MARRIAGEBEAD TO VERTICAL PANEL JOINT

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER1

4" - 14 "LOW PROFILE"FASTENER

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

FIELD DRILL 3 8"ØWEEP HOLES @ 24"O.C. AND AT EACHVERTICAL JOINTWHEN POSSIBLE(NOT BY KINGSPAN)

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-BS-06-KSV

2021

KS SERIES - VERTICAL INSTALLATION

OVERHANG WITHBASE "J" EXTRUSION

www.kingspanpanels.com

NOTE:ENSURE THERE ARE NOGAPS IN SEALANT BEAD.COVERAGE MUST BECONTINUOUS

MARRIAGE BEAD TO VERTICAL JOINT(FEMAILE INTERIOR JOINT TO HAVE EITHERFACTORY OR FIELD CONTINUOUS BUTYLSEALANT)

BASE FLASHING

CONTINUOUS HEAVY BEADOF BUTYL SEALANT

PANEL CLIP TO BE SET IN BED OF BUTYLSEALANT

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

BASE ANGLE W/ MIN. 3" VERT.LEG FOR PANEL ATTACHMENT,BASE CHANNEL SET IN SEALANT(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-BS-07-KSV

2021

KS SERIES - VERTICAL INSTALLATION

BASE DETAILMARRIAGE BEAD

ISOMETRIC www.kingspanpanels.com

PROFILED OUTSIDECORNER TRIM

POP RIVETS @ 8" O.C.

34" PHIL. PAN HEAD @

8" O.C.

INSIDE CORNER TRIM

CONTINUOUSBUTYL SEALANT

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

F.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

ATTACHMENT CLIP(NOT BY KINGSPAN)

WILL VARY WITHFIELD CONDITION

WIL

L VA

RY

WIT

HFI

ELD

CO

ND

ITIO

N

FIELD CUT

14" - 14 THROUGH FASTENERS

W/ 118" BONDED WASHER

(AS REQUIRED FOR WIND LOAD)

POP RIVETS @ 8" O.C.

CONTINUOUS BUTYLTAPE / SEALANT

CONTINUOUS BUTYLTAPE / SEALANT

FIELD CUT

REVISIONREVISION # DATE

1 1/27/21

OUTSIDE CORNERWITH PROFILED TRIM

DETAIL #:

RELEASE:

CI-OC-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

INSIDE CORNER TRIM

OUTSIDE CORNER TRIM

F.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

34" PHIL. PAN HEAD @

8" O.C.ATTACHMENT CLIP(NOT BY KINGSPAN)

CONTINUOUSBUTYL SEALANT

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

WILL VARY WITHFIELD CONDITION

WIL

L VA

RY

WIT

HFI

ELD

CO

ND

ITIO

N

FIELD CUT

14" - 14 "LOW PROFILE"

THROUGH FASTENER WITH11

8" BONDED WASHER (ASREQUIRED FOR WIND LOAD)

POP RIVETS @ 8" O.C.

POP RIVETS @ 8" O.C.

CONTINUOUS BUTYLTAPE / SEALANT

CONTINUOUS BUTYLTAPE / SEALANT

REVISIONREVISION # DATE

1 1/27/21

OUTSIDE CORNERWITH FLAT TRIM

DETAIL #:

RELEASE:

CI-OC-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CORNER EXTRUSION MALE

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

WILL VARY WITHFIELD CONDITION

WIL

L VA

RY

WIT

HFI

ELD

CO

ND

ITIO

N

FIELD CUT

F.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

THROUGH FASTENER WITH11

8" BONDED WASHER (ASREQUIRED FOR WIND LOAD)

VERTICAL SUPPORT(NOT BY KINGSPAN)

CONTINUOUS BUTYLSEALANT

14" - 14 "LOW PROFILE"

FASTENER

CORNER EXTRUSIONFEMALE

REVISIONREVISION # DATE

1 1/27/21

OUTSIDE CORNERW/ EXTRUSION

DETAIL #:

RELEASE:

CI-OC-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

34" PHIL. PAN HEAD @ 8" O.C.

OUTSIDE CORNER TRIM

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

PROFILED INSIDE CORNERTRIM W/ POP RIVETS @ 8"O.C.

CONTINUOUS BUTYL SEALANT

CONTINUOUSBUTYL SEALANT

WIL

L VA

RY

WIT

HFI

ELD

CO

ND

ITIO

N

FIELD CUT

14" - 14 THROUGH FASTENERS

W/ 118" BONDED WASHER

(AS REQUIRED FOR WIND LOAD)

34" PHIL. PAN HEAD

CONTINUOUS BUTYLTAPE / SEALANT

CONTINUOUS BUTYLTAPE / SEALANT

REVISIONREVISION # DATE

1 1/27/21

F.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

INSIDE CORNERWITH PROFILED TRIM

DETAIL #:

RELEASE:

CI-IC-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

34" PHIL. PAN HEAD @ 8" O.C.

INSIDE CORNER TRIM W/POP RIVETS @ 8" O.C.

OUTSIDE CORNER TRIM

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

CONTINUOUSBUTYL SEALANT

WIL

L VA

RY

WIT

HFI

ELD

CO

ND

ITIO

N

WILL VARY WITHFIELD CONDITION

FIELD CUT

14" - 14 "LOW PROFILE"

THROUGH FASTENER WITH11

8" BONDED WASHER (ASREQUIRED FOR WIND LOAD)

CONTINUOUSBUTYL SEALANT

14" - 14 "LOW PROFILE"

THROUGH FASTENER WITH11

8" BONDED WASHER (ASREQUIRED FOR WIND LOAD)

CONTINUOUS BUTYLTAPE / SEALANT

REVISIONREVISION # DATE

1 1/27/21

FILL ALL VOIDS WITHF.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

INSIDE CORNERWITH FLAT TRIM

DETAIL #:

RELEASE:

CI-IC-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

VERTICAL SUPPORT(NOT BY KINGSPAN)

CORNER EXTRUSION BASE

14" - 14 "LOW PROFILE"

FASTENER

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

CONTINUOUSBUTYL SEALANT

14" - 14 "LOW PROFILE"

THROUGH FASTENER WITH11

8" BONDED WASHER (ASREQUIRED FOR WIND LOAD)

CORNER EXTRUSION CAP

CONTINUOUSBUTYL SEALANT

F.I.P. INSULATIONAS REQUIRED(NOT BY KINGSPAN)

REVISIONREVISION # DATE

1 1/27/21

INSIDE CORNERWITH EXTRUSION

DETAIL #:

RELEASE:

CI-IC-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CORNER TRIM

BASE TRIM

CONTINUOUSBUTYL SEALANT

PLACE CORNER TRIM OVERBASE TRIM FOR PROPERDRAINAGE

SLABSLAB

CONTINUOUS BUTYLSEALANT AT LAPBETWEEN UPPERAND LOWER TRIMPIECE

FRAMING NOT SHOWN FORCLARITY OF DETAIL

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-IC-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

INSIDE CORNER LAP ATBASE TRIM EXPANDED

www.kingspanpanels.com

CORNER TRIM

BASE TRIM

CONTINUOUSBUTYL SEALANT

CONTINUOUS BUTYLSEALANT FROM BOTTOM TOTOP OF CORNER TRIM WITHMARRIAGE BEADS AT ALLPANEL JOINTS AND ALLHORIZONTAL BEADS OFBUTYL

SLABSLAB

CONTINUOUS BUTYLSEALANT AT LAPBETWEEN UPPERAND LOWER TRIMPIECE

CONTINUOUSBUTYL SEALANTOVER CORNERTRIM

MARRIAGE BEAD TOHORIZONTAL BEAD OFSEALANT

FRAMING NOT SHOWN FORCLARITY OF DETAIL

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-IC-05-KSV

2021

KS SERIES - VERTICAL INSTALLATION

INSIDE CORNER LAP ATBASE TRIM ENGAGED

www.kingspanpanels.com

LOWER CORNER TRIM

CONTINUOUS BUTYLSEALANT FROM BOTTOM TOTOP OF CORNER TRIM WITHMARRIAGE BEADS AT ALLPANEL JOINTS AND ALLHORIZONTAL BEADS OFBUTYL

FRAMING NOT SHOWN FORCLARITY OF DETAIL

UPPER CORNER TRIM

TRIM LAP

3"LAP UPPER CORNERTRIM MIN. 3" OVERLOWER CORNERTRIM

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-IC-06-KSV

2021

KS SERIES - VERTICAL INSTALLATION

INSIDE CORNER TRIM LAPEXPANDED

www.kingspanpanels.com

LOWER CORNER TRIM

CONTINUOUS BUTYLSEALANT FROM BOTTOM TOTOP OF CORNER TRIM WITHMARRIAGE BEADS AT ALLPANEL JOINTS AND ALLHORIZONTAL BEADS OFBUTYL

FRAMING NOT SHOWN FORCLARITY OF DETAIL

UPPER CORNER TRIM

TRIM LAP

3"LAP UPPER CORNERTRIM MIN. 3" OVERLOWER CORNERTRIM

CONTINUOUS BUTYLSEALANT FROM BOTTOM TOTOP OF CORNER TRIM WITHMARRIAGE BEADS AT ALLPANEL JOINTS AND ALLHORIZONTAL BEADS OFBUTYL

REVISIONREVISION # DATE

0 01/01/21

DETAIL #:

RELEASE:

CI-IC-07-KSV

2021

KS SERIES - VERTICAL INSTALLATION

INSIDE CORNER TRIM LAPENGAGED

www.kingspanpanels.com

EXPOSED SEALANT(NOT BY KINGSPAN)

HEAD FLASHING

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

CONTINUOUS BUTYLSEALANT BOTH SIDES OFTRIM W/ MARRIAGE BEAD TOVERTICAL PANEL JOINT1

4" - 14 "LOW PROFILE"THROUGH FASTENER @ 12" O.C.

BASE TRIM W/ POP RIVETS@ 8" O.C.

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

FRAMED OPENING(NOT BY KINGSPAN)

REVISIONREVISION # DATE

5 11/30/21

DRIP FLASHING

CONTINUOUS BUTYL SEALANTBETWEEN TRIMS

CONTINUOUSBUTYL SEALANT

FRAMED OPENINGTWO-PIECE HEAD

DETAIL #:

RELEASE:

CI-FO-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CAP TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER @ 12" O.C.CAP TRIM

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

FIELD DRILL 3 8" WEEP HOLESTO ALIGN WITH PANEL JOINTS

EXPOSED SEALANT(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TOVERTICAL PANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

FRAMED OPENING(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

FRAMED OPENINGHEAD W/ "DRIP EDGE"

DETAIL #:

RELEASE:

CI-FO-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CAP TRIM

POP RIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER @ 12" O.C.

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM

FRAMED OPENING(NOT BY KINGSPAN)

EXTERIOR CAP TRIM W/POP RIVETS @ 8" O.C.

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

BUTYL SEALANTBETWEEN TRIMS CONTINUOUS BUTYL TAPE /

SEALANT

REVISIONREVISION # DATE

0 01/01/21

FRAMED OPENINGTWO PIECE JAMB

DETAIL #:

RELEASE:

CI-FO-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FRAMED OPENING(NOT BY KINGSPAN)

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM

JAMB TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

FASTENER (AS REQUIRED)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

FIELD BEND(AS REQUIRED)

CONTINUOUS BUTYL TAPE /SEALANT

CONTINUOUS BUTYL SEALANT

REVISIONREVISION # DATE

5 11/30/21

CAP TRIM

CONTINUOUS BUTYL SEALANTBETWEEN TRIMS

FRAMED OPENINGONE PIECE JAMB

DETAIL #:

RELEASE:

CI-FO-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

SILL TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

FASTENER (AS REQUIRED)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

FIELD BEND(AS REQUIRED)

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

SLOPE

CONTINUOUS BUTYLSEALANT

FRAMED OPENING(NOT BY KINGSPAN)

REVISIONREVISION # DATE

5 11/30/21

CONTINUOUS BUTYLSEALANT BETWEEN TRIMS

CAP TRIM

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

FRAMED OPENINGONE PIECE SILL

DETAIL #:

RELEASE:

CI-FO-05-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CHANNEL TRIM

PHIL. PAN HEAD FASTENERS

CONTINUOUS BUTYL SEALANT

CHANNEL TRIM

PHIL. PAN HEAD FASTENERS

CONTINUOUS BUTYL SEALANT

CONTRACTOR MAY REMOVE A PORTIONOF THE FOAM CORE AND INSERT TREATEDLUMBER (NOT BY KINGSPAN) TO REINFORCELARGE OPENINGS

CAP TRIM

CONTRACTOR MAY REMOVE APORTION OF THE FOAM COREAND INSERT TREATED LUMBER(NOT BY KINGSPAN) TOREINFORCE LARGE OPENINGS

DOOR CASING(NOT BY KINGSPAN)

THROUGH BOLT ASREQUIRED FOR ATTACHMENTOF DOOR CASING(NOT BY KINGSPAN)

CONTINUOUSBUTYL SEALANT

REVISIONREVISION # DATE

0 01/01/21

FRAMED OPENINGPARTITION

DETAIL #:

RELEASE:

CI-FO-06-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CAP TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER

FRAMED OPENING(NOT BY KINGSPAN)

CAP TRIM

FIELD DRILL 3 8" WEEP HOLESTO ALIGN WITH PANEL JOINTS

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TO VERTICALPANEL JOINT

HEADER TRIM(OPTIONAL)

FASTENER(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

1

2

3

TRIM INSTALLATION SEQUENCE:1 INSTALL HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS2 INSTALL INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO

INSTALLING THE PANEL AND THROUGH FASTENERS3 INSTALL EXTERIOR CAP TRIM

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

OVERHEAD DOORTWO PIECE HEADER

DETAIL #:

RELEASE:

CI-FO-07-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

BASE TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER

DRIP FLASHING

FRAMED OPENING(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT W/MARRIAGE BEAD TO VERTICALPANEL JOINT

FASTENER(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

HEADER TRIM(OPTIONAL)EXPOSED SEALANT

(NOT BY KINGSPAN)

TRIM INSTALLATION SEQUENCE:1 INSTALL HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS2 INSTALL DRIP FLASHING & ALL APPLICABLE SEALANTS PRIOR TO

INSTALLING THE PANEL AND THROUGH FASTENERS3 INSTALL EXTERIOR CAP TRIM

1

2

3

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TO VERTICALPANEL JOINT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

OVERHEAD DOORHEAD W/ DRIP EDGE

DETAIL #:

RELEASE:

CI-FO-08-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CAP TRIM

POP RIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENER

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM

FRAMED OPENING(NOT BY KINGSPAN)

CAP TRIM W/ POP RIVETS @ 8" O.C.

EXPOSED SEALANT(NOT BY KINGSPAN)

FASTENER(NOT BY KINGSPAN)

JAMB TRIM(OPTIONAL)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV FOR TYPICAL TRIM LAP INSTRUCTIONS

TRIM INSTALLATION SEQUENCE:1 INSTALL JAMB TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS2 INSTALL INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO

INSTALLING THE PANEL AND THROUGH FASTENERS3 INSTALL EXTERIOR CAP TRIM

1

2

3

REVISIONREVISION # DATE

5 11/30/21

CONTINUOUS BUTYL SEALANTBETWEEN TRIMS

OVERHEAD DOORTWO-PIECE JAMB

DETAIL #:

RELEASE:

CI-FO-09-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 "LOW PROFILE"

THROUGH FASTENER

FRAMED OPENING(NOT BY KINGSPAN)

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

TWO PIECE HEADEXTRUSION BASEW/ FOAM CLOSURE

EXPOSED SEALANT(NOT BY KINGSPAN)

FIELD DRILL 3 8" Ø WEEPHOLES @ 24" O.C. AND AT ALLVERTICAL JOINTS WHEREPOSSIBLE(NOT BY KINGSPAN)

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

TWO PIECE HEADEXTRUSION CAP

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TO VERTICALPANEL JOINT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

HEADER W/EXTRUSION

DETAIL #:

RELEASE:

CI-FO-10-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FRAMED OPENING(NOT BY KINGSPAN)

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

CONTINUOUS BUTYL SEALANTBOTH SIDES OF EXTRUSION

TWO PIECE JAMBEXTRUSION BASE W/FOAM CLOSURE

FIELD CUT PANELS WHEREREQUIRED

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

TWO PIECE JAMBEXTRUSION CAP

REVISIONREVISION # DATE

0 01/01/21

14" - 14 "LOW PROFILE"

THROUGH FASTENER

JAMB W/ EXTRUSIONDETAIL #:

RELEASE:

CI-FO-11-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CONTINUOUS BUTYL SEALANT

SILL EXTRUSION

FRAMED OPENING(NOT BY KINGSPAN)

DOOR/WINDOW FRAMEAND COMPONENTS(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

FIELD CUT PANELWHERE REQUIRED

OPTIONAL WIPERGASKET

(FIELD INSTALLED) 14" - 14 "LOW PROFILE"

THROUGH FASTENER

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANT INVERTICAL PANEL JOINT INSTALLERTO ENSURE THERE ARE NO GAPSIN SEALANT

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

SILL W/ EXTRUSIONDETAIL #:

RELEASE:

CI-FO-12-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 "LOW PROFILE"

THROUGH FASTENER

14" - 14 "LOW PROFILE"

THROUGH FASTENER

FRAMED OPENING(NOT BY KINGSPAN)

HEADER TRIM(OPTIONAL)

FASTENER(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

TWO PIECE HEADEXTRUSION CAP

CONTINUOUS BUTYL SEALANTBOTH SIDES OF EXTRUSION W/MARRIAGE BEAD TO VERTICALPANEL JOINT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

FIELD DRILL 3 8" Ø WEEPHOLES @ 24" O.C. AND AT ALLVERTICAL JOINTS WHEREPOSSIBLE(NOT BY KINGSPAN)

TWO PIECE HEADEXTRUSION BASEW/ FOAM CLOSURE

REVISIONREVISION # DATE

0 01/01/21

O.H. DOOR HEAD W/EXTRUSION

DETAIL #:

RELEASE:

CI-FO-13-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 "LOW PROFILE"

THROUGH FASTENER

FRAMED OPENING(NOT BY KINGSPAN)

CONTINUOUS BUTYLSEALANT BOTH SIDES OFEXTRUSION

FASTENER(NOT BY KINGSPAN)

JAMB TRIM(OPTIONAL)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

TWO PIECE JAMBEXTRUSION BASE

FIELD CUT PANELS WHEREREQUIRED

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

TWO PIECE JAMBEXTRUSION CAP

EXPOSED SEALANT(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

O.H. DOOR JAMB W/EXTRUSION

DETAIL #:

RELEASE:

CI-FO-14-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

CONTINUOUS 3" X 3"(GAUGE TO MATCH GIRT)(NOT BY KINGSPAN)

STACK TRIM W/POP RIVETS @8" O.C.

STACK FLASHING

CONTINUOUS BUTYLSEALANT BELOW BASEFLASHING

CONTINUOUS BUTYL SEALANT BOTHSIDES OF TRIM W/ MARRIAGE BEADTO VERTICAL PANEL JOINT

FASTEN AS REQUIRED(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

STACK JOINTDETAIL #:

RELEASE:

CI-SJ-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

HORIZONTAL SUPPORT(NOT BY KINGSPAN)

CONTINUOUS 3" X 3"(GAUGE TO MATCH GIRT)(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT BOTHSIDES OF EXTRUSION W/ MARRIAGEBEAD TO VERTICAL PANEL JOINT

FASTEN AS REQUIRED(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

TWO PIECE STACKEXTRUSION CAP

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

14" - 14 "LOW PROFILE"

THROUGH FASTENER

COMPRESSIBLEFOAM CLOSURE

FIELD DRILL 3 8"ØWEEP HOLES @ 24"O.C. AND AT ALLVERTICAL JOINTSWHERE POSSIBLE(NOT BY KINGSPAN)

TWO PIECE STACKEXTRUSION BASE

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

STACK JOINT WITHEXTRUSION

DETAIL #:

RELEASE:

CI-SJ-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CONTINUOUS CLEAT

WRAP MEMBRANEADHERE TO EXTERIORPANEL FACE(NOT BY KINGSPAN)

PARAPET BLOCKINGAND COMPONENTS(NOT BY KINGSPAN)

MEMBRANE ROOF &PARAPET BACKER(NOT BY KINGSPAN)

FASTENER TO PARAPETBACKER (NOT BY KINGSPAN)

PARAPET TRIM

14" - 14 "LOW PROFILE"

FASTENER @ 8" O.C.

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

PARAPETWITH FLUSH TRIM

DETAIL #:

RELEASE:

CI-PR-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

POP RIVET @ 8" O.C.

WRAP MEMBRANE(NOT BY KINGSPAN)

PARAPET BACKER(NOT BY KINGSPAN)

FASTENER TO PARAPETBACKER (NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUT WASHER

WRAP MEMBRANEADHERE TO EXTERIORPANEL FACE(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

PARAPET TRIM

PARAPET BLOCKINGAND COMPONENTS(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

PARAPETWITH PROFILED TRIM

DETAIL #:

RELEASE:

CI-PR-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

WRAP MEMBRANE(NOT BY KINGSPAN)ADHERE TO EXTERIORPANEL FACE

MEMBRANE ROOF &PARAPET BACKER(NOT BY KINGSPAN)

FASTENER TO PARAPETBACKER (NOT BY KINGSPAN)

PARAPET EXTRUSION

14" - 14 HEX HEAD

FASTENERS WITH WASHER

CONTINUOUSBUTYL SEALANT

14" - 14 "LOW PROFILE"

THROUGH FASTENER

PARAPET CAP TRIM

FIELD CUT MALE JOINTSWHERE REQUIRED

14" - 14 HEX HEAD FASTENERS

WITHOUT WASHER

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

REVISIONREVISION # DATE

0 01/01/21

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

PARAPETWITH EXTRUSION

DETAIL #:

RELEASE:

CI-PR-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CONTINUOUS BUTYLSEALANT W/ MARRIAGEBEAD TO VERTICAL JOINT

(2) 14" - 14 HEXHEAD FASTENERSPER CLIP

12 GA. HIDDEN FASTENERCLIP(1 PER PANEL, PER GIRT)

BASE TRIM W/ POP RIVETS@ 8" O.C.

MEMBRANE ROOF ANDACCESSORIES(NOT BY KINGSPAN

FLAT STOCK MATERIAL(FIELD BREAK BY OTHERS)

BASE FLASHING

BASE FLASHING

FIELD OR FACTORYINSTALLED CONTINUOUSBUTYL SEALANT INVERTICAL PANEL JOINTINSTALLER TO ENSURETHERE ARE NO GAPS INSEALANT

REVISIONREVISION # DATE

0 01/01/21

WALL TO ROOFDETAIL #:

RELEASE:

CI-WR-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

CONTINUOUS BUTYLSEALANT W/MARRIAGE BEAD TOVERTICAL JOINT

(2) 14" - 14 HEX HEADFASTENERS PERCLIP

12 GA. HIDDEN FASTENERCLIP(1 PER PANEL, PER GIRT)

BASE TRIM W/ POP RIVETS

MEMBRANE ROOF,FRAMING ANDACCESSORIES(NOT BY KINGSPAN)

BASE FLASHING

(2) 14" - 14 HEX HEADFASTENERS PERCLIP

CONTINUOUS BUTYLSEALANT IN INTERIORJOINT

12 GA. HIDDEN FASTENERCLIP(1 PER PANEL, PER GIRT)

MIN

6"

MEMBRANE(NOT BY KINGSPAN)

SUPPORT(NOT BY KINGSPAN)

SUPPORT(NOT BY KINGSPAN)

FIELD OR FACTORYINSTALLED CONTINUOUSBUTYL SEALANT INVERTICAL PANEL JOINTINSTALLER TO ENSURETHERE ARE NO GAPS INSEALANT

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

CONTINUOUS BUTYL SEALANTW/ MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

CONTINUOUS WALL ATROOF / CANOPY

DETAIL #:

RELEASE:

CI-WR-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

BASE TRIM W/ POPRIVETS @ 8" O.C.

CONTINUOUS BUTYLSEALANT BOTH SIDESOF TRIM

14" - 14 "LOW PROFILE"

THROUGH FASTENERW/ 11

8" BONDED WASHER

SOFFIT TRIM

CONTINUOUS BUTYLSEALANT BOTH SIDESOF TRIM W/ MARRIAGEBEAD TO INTERIORJOINT

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

(2) 14" - 14 HEX HEADFASTENERS WITHOUTWASHER PER CLIP

POP RIVETS @ 8" O.C.

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

WALL ABOVE TOHORIZONTAL SOFFIT

DETAIL #:

RELEASE:

CI-SO-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 "LOW PROFILE"

THROUGH FASTENER

CONTINUOUS BUTYLSEALANT

OUTSIDE CORNERTRIM

INSIDE CORNER TRIMW/ POP RIVETS @ 8"O.C.

BACKER ROD ANDSEALANT(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

(2) 14" - 14 HEX HEADFASTENERS WITHOUTWASHER PER CLIP

BUTYL SEALANT ORTAPE

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORYINSTALLED CONTINUOUSBUTYL SEALANT INVERTICAL PANEL JOINTINSTALLER TO ENSURETHERE ARE NO GAPS INSEALANT

CONTINUOUS BUTYLSEALANT W/ MARRIAGEBEAD TO FRONT FACEOF PANEL AT JOINTLOCATIONS

WALL BELOW TOHORIZONTAL SOFFIT

DETAIL #:

RELEASE:

CI-SO-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

BASE TRIM W/ POPRIVETS @ 8" O.C.

14" - 14 "LOW PROFILE"

THROUGH FASTENERSOFFIT FLASHING

CONTINUOUS BUTYLSEALANT BOTH SIDESOF TRIM W/ MARRIAGEBEAD TO INTERIORJOINT

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PERSUPPORT)SET CLIP IN BUTYLSEALANT

14" - 14 HEX HEAD

FASTENERS WITHOUTWASHER

POP RIVETS @ 8" O.C.

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORY INSTALLEDCONTINUOUS BUTYL SEALANTIN VERTICAL PANEL JOINTINSTALLER TO ENSURE THEREARE NO GAPS IN SEALANT

CONTINUOUS BUTYL SEALANTBOTH SIDES OF TRIM W/MARRIAGE BEAD TO FRONTFACE OF PANEL AT JOINTLOCATIONS

WALL ABOVE TOVERTICAL SOFFIT

DETAIL #:

RELEASE:

CI-SO-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

14" - 14 "LOW PROFILE"

THROUGH FASTENER

CONTINUOUS BUTYLSEALANT

OUTSIDE CORNERTRIM

INSIDE CORNER TRIMW/ POP RIVETS @ 8"O.C.

BACKER ROD ANDSEALANT(NOT BY KINGSPAN)

12 GA. STAINLESS STEELHIDDEN FASTENER CLIP(1 PER PANEL, PER SUPPORT)SET CLIP IN BUTYL SEALANT

(2) 14" - 14 HEX HEADFASTENERS WITHOUTWASHER PER CLIP

CONTINUOUS BUTYLSEALANT MARRIAGEBEAD TO PANEL FACEAT JOINTS

REVISIONREVISION # DATE

0 01/01/21

FIELD OR FACTORYINSTALLED CONTINUOUSBUTYL SEALANT INVERTICAL PANEL JOINTINSTALLER TO ENSURETHERE ARE NO GAPS INSEALANT

CONTINUOUS BUTYLSEALANT W/ MARRIAGEBEAD TO FRONT FACEOF PANEL AT JOINTLOCATIONS

WALL BELOW TOVERTICAL SOFFIT

DETAIL #:

RELEASE:

CI-SO-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

FASTENER AS REQUIRED

SEALANT (NOT BY KINGSPAN)

2PC. FLASHING AS REQUIRED(FIELD FABRICATED FROMFLATSTOCK)

EXPANDABLE INSULATION(NOT BY KINGSPAN)

SEALANT (NOT BY KINGSPAN)

SEALANT(NOT BY KINGSPAN)

2 PC. FLASHING AS REQUIRED

FASTENER AS REQUIRED

SEALANT (NOT BY KINGSPAN)

FASTENER AS REQUIRED

FASTENER AS REQUIRED

NOTE: FLASHING AT PIPE PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE PROVIDED(NOT BY KINGSPAN)

NOTE:DO NOT ALIGN PENETRATIONSAT PANEL JOINT LOCATIONS.

EXPANDABLE INSULATION(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

PIPE PENETRATIONSECTION

DETAIL #:

RELEASE:

CI-PE-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

INSULATED PANEL

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

POP RIVETS(QUANTITY REQUIRED SHALLBE DETERMINED BY INSTALLER)

SILICONE SEALANT ATPERIMETER OF PIPE(NOT BY KINGSPAN)

TWO PIECE FLASHINGWITH 12" HEM. BEDSEAL TO PANEL WITHBUTYL SEALANT (BLIND)COPE FLASHING (FIELDFABRICATED FROMFLATSTOCK)

NOTE:THIS DETAIL ASSUMESPENETRATION OCCURSAFTER PANEL IS INSTALLED

PIPE PENETRATION(NOT BY KINGSPAN)

NOTE:DO NOT ALIGN PENETRATIONSAT PANEL JOINT LOCATIONS.

SILICONE SEALANTBETWEEN FLASHINGS(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE DETERMINED BY INSTALLER(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

PIPE PENETRATIONISOMETRIC

DETAIL #:

RELEASE:

CI-PE-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

INSULATED PANEL

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

POP RIVETS(QUANTITY REQUIRED SHALLBE DETERMINED BY INSTALLER)

TWO PIECE FLASHINGWITH 12" HEM. BEDSEAL TO PANEL WITHBUTYL SEALANT (BLIND)COPE FLASHING(NOT BY KINGSPAN)

SILICONE SEALANTBETWEEN FLASHINGS(NOT BY KINGSPAN)KNIFE PENETRATION(NOT BY KINGSPAN)

SILICONE SEALANT ATPERIMETER OF KNIFE(NOT BY KINGSPAN)

INSULATED PANEL

POP RIVETS

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

KNIFE PENETRATION

SILICONE SEALANT ATPERIMETER OF KNIFE(NOT BY KINGSPAN)

FILL VOID WITH F.I.PINSULATION(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE DETERMINEDBY INSTALLER(NOT BY KINGSPAN)

NOTE:DO NOT ALIGNPENETRATIONSAT PANEL JOINTLOCATIONS.

NOTE: THIS DETAIL ASSUMES PENETRATION OCCURS AFTER PANEL IS INSTALLED REVISION

REVISION # DATE0 01/01/21

KNIFE PLATEPENETRATION

DETAIL #:

RELEASE:

CI-PE-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

INSULATED PANEL

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

SILICONE SEALANT ATPERIMETER OF KNIFE(NOT BY KINGSPAN)

TWO PIECE FLASHINGWITH 12" HEM. BEDSEAL TO PANEL WITHBUTYL SEALANT (BLIND)COPE FLASHING(NOT BY KINGSPAN)

SILICONE SEALANTBETWEEN FLASHINGS(NOT BY KINGSPAN)

NOTE: THIS DETAIL ASSUMES PENETRATION OCCURS AFTER PANEL IS INSTALLED

KNIFE PENETRATION(NOT BY KINGSPAN)

POP RIVETS(QUANTITY REQUIREDSHALL BE DETERMINEDBY INSTALLER)

NOTE: FLASHING AT PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE DETERMINEDBY INSTALLER(NOT BY KINGSPAN)

NOTE:DO NOT ALIGN PENETRATIONSAT PANEL JOINT LOCATIONS.

REVISIONREVISION # DATE

0 01/01/21

KNIFE PLATEPENETRATION ISOMETRIC

DETAIL #:

RELEASE:

CI-PE-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

NOTE: THIS DETAIL ASSUMES PENETRATION OCCURS AFTER PANEL IS INSTALLED

INSULATED PANEL

POP RIVETS

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

BEAM PENETRATION

SILICONE SEALANT ATPERIMETER OF BEAM(NOT BY KINGSPAN)

FILL VOID WITH F.I.PINSULATION(NOT BY KINGSPAN)

INSULATED PANEL

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

TWO PIECE FLASHINGWITH 12" HEM. BEDSEAL TO PANEL WITHBUTYL SEALANT (BLIND)COPE FLASHING(NOT BY KINGSPAN)

BEAM PENETRATION(NOT BY KINGSPAN)

SILICONE SEALANT ATPERIMETER OF BEAM(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE DETERMINEDBY INSTALLER(NOT BY KINGSPAN)

POP RIVETS(QUANTITY REQUIREDSHALL BE DETERMINEDBY INSTALLER)

SILICONE SEALANTBETWEEN FLASHINGS(NOT BY KINGSPAN)

NOTE:DO NOT ALIGNPENETRATIONSAT PANEL JOINTLOCATIONS.

REVISIONREVISION # DATE

0 01/01/21

BEAM PENETRATIONDETAIL #:

RELEASE:

CI-PE-05-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

NOTE: THIS DETAIL ASSUMES PENETRATION OCCURS AFTER PANEL IS INSTALLED

INSULATED PANEL

SILICONE SEALANTAT TOP OF FLASHING(NOT BY KINGSPAN)

SILICONE SEALANT ATPERIMETER OF BEAM(NOT BY KINGSPAN)

TWO PIECE FLASHINGWITH 12" HEM. BEDSEAL TO PANEL WITHBUTYL SEALANT (BLIND)COPE FLASHING(NOT BY KINGSPAN)

SILICONE SEALANTBETWEEN FLASHINGS(NOT BY KINGSPAN)

BEAM PENETRATION(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONSTO BE FIELD FABRICATED FROM FLATSTOCKSHEETS AS NECESSARY. QUANTITY OFFLATSTOCK REQUIRED SHALL BE DETERMINEDBY INSTALLER(NOT BY KINGSPAN)

POP RIVETS(QUANTITY REQUIREDSHALL BE DETERMINEDBY INSTALLER)

NOTE:DO NOT ALIGN PENETRATIONSAT PANEL JOINT LOCATIONS. REVISION

REVISION # DATE0 01/01/21

BEAM PENETRATIONISOMETRIC

DETAIL #:

RELEASE:

CI-PE-06-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

MIN. 3"

TRIM LAP

MIN. 3"

TRIM LAP

(2) BEADSBUTYL SEALANT

REVISIONREVISION # DATE

0 01/01/21

TRIM END LAPDETAIL #:

RELEASE:

CI-TL-01-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

MIN. 3"

TRIM LAP

MIN. 3"

TRIM LAP

(2) BEADSBUTYL SEALANT

FIELD NOTCH HEM(S)AS REQUIRED(NOT BY KINGSPAN)

REVISIONREVISION # DATE

0 01/01/21

TRIM LAP WITH HEMDETAIL #:

RELEASE:

CI-TL-02-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

(2) BEADSBUTYL SEALANT

NOM. 1 4"

GAP

8" LONG LAP STRIP

REVISIONREVISION # DATE

0 01/01/21

TRIM END LAP WITHLAP STRIP

DETAIL #:

RELEASE:

CI-TL-03-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

INTERIOR CAP TRIM AT HEAD

EXTERIOR CAP TRIM AT HEAD

EXTE

RIO

R C

AP T

RIM

AT

JAM

B

FIELD NOTCH AND OVERLAPTRIMS, POP RIVET AND SEAL ASNECESSARY (NOT BY KINGSPAN)DO NOT PUNCTURE FLEXWRAP

FIELD MITER AND OVERLAPTRIMS, POP RIVET ASNECESSARY (NOT BY KINGSPAN)

FIELD CUT/NOTCH CAPTRIM AT CORNERS TOALLOW FOR LAP (NOT BY KINGSPAN)

EXTERIOR CAP TRIM AT SILL

FIELD MITER AND OVERLAPTRIMS, POP RIVET AND SEAL ASNECESSARY (NOT BY KINGSPAN)

FIELD CUT/NOTCH CAPTRIM AT CORNERS TOALLOW FOR LAP(NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

SEALANT END DAMUNDER FLEXWRAP

FIELD DRILL 3 8" Ø WEEP HOLES(NOT BY KINGSPAN)

TRIM INSTALLATION SEQUENCE:1 INTERIOR JAMB TRIM2 INTERIOR HEAD TRIM WITH TABS DOWN3 SILL TRIM WITH TABS UP4 EXTERIOR JAMB TRIM5 EXTERIOR HEAD TRIM6 EXTERIOR SEALANTS AS REQUIRED

INTERIOR JAMB TRIM1

INTERIOR HEAD TRIMWITH TABS BENT DOWN

2

SILL TRIM WITH TABSBENT UP

3

EXTERIOR HEAD TRIM W/5

EXTERIOR JAMB TRIM4

6

REVISIONREVISION # DATE

5 11/30/21

INTERIOR CAP TRIMSSHINGLE LAPPED

TRIM LAP W/ FLEXWRAP ATFRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-04-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

EXTE

RIO

R C

APTR

IM A

T JA

MB

MIN. 3" TAB FOLD OVERINTERIOR JAMB TRIM,APPLY SEALANT INBETWEEN (TYPICALBOTH ENDS)

SILL TRIMMIN. 3" TAB FOLD OVERINTERIOR JAMB TRIM, APPLYSEALANT IN BETWEEN(TYPICAL BOTH ENDS)

1

TRIM INSTALLATION SEQUENCE:1 INTERIOR JAMB TRIM (NOTCH)2 DRIP FLASHING HEAD TRIM WITH TABS BENT DOWNS3 SILL TRIMS WITH TABS BENT UP4 EXTERIOR JAMB TRIM

5 EXTERIOR CAP TRIM AT HEAD

EXPLODED VIEW

INTE

RIO

R C

APTR

IM A

T JA

MB

2

3

4

4

INTE

RIO

R C

APTR

IM A

T JA

MB

EXTE

RIO

R C

APTR

IM A

T JA

MB

1

DRIP FLASHING AT HEAD

CAP TRIM AT HEAD

5

REVISIONREVISION # DATE

0 01/01/21

TRIM LAP ATFRAMED OPENING

INSTALLATION

DETAIL #:

RELEASE:

CI-TL-05-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

USE DUPONTFLEXWRAP NFTAPE 6" x 6"PATCH

JAMB TRIM,SHINGLE LAPPED

SILL TRIM

4" LAP BEDSEALED INBUTYL CAULK1" TAB UP BED SEALED IN

BUTYL CAULK

4" LAP BED SEALED INBUTYL CAULK

1" TAB DOWN BED SEALED INBUTYL CAULK

DRIP FLASHING AT HEAD

USE DUPONTFLEXWRAP NF

REVISIONREVISION # DATE

5 11/30/21

CARRY FIELD APPLIED REARSEAL NON-SKINNING BUTYLSEALANT BEAD OVER TOPOF THE FLEXWRAP TAPE

CARRY FIELD APPLIED REARSEAL NON-SKINNING BUTYLSEALANT BEAD OVER TOPOF THE FLEXWRAP TAPE

PERFORM THIS WORKPRIOR TO PANELINSTALLATION

FLEXWRAP ATFRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-06-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

VERTICAL JOINT EXTRUSIONS

2" PANEL BASE "A"EXTRUSIONPART # 2-4045

2" PANEL BASE "C"EXTRUSIONPART # 2-4053

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

2" SOFFIT EXTRUSION "A"PART # 2-4056

2" SOFFIT EXTRUSION "B"PART # 2-4060

TWO PIECE OPENINGEXTRUSION CAPPART # 2-4069

2" TWO PIECE OPENINGEXTRUSION BASEPART # 2-4071 PARAPET EXTRUSION

PART # 2-1598

2" CORNERFEMALE EXTRUSIONPART # 2-3998

2" CORNERMALE EXTRUSIONPART # 2-4083

SILL EXTRUSIONPART # 2-4064

TOP HAT EXTRUSIONPART # 2-4077

FLUSH INSERTPART # 2-4078

RECESSEDTOP HAT EXTRUSIONPART # 2-4074

RECESSEDINSERTPART # 2-4076

REVISIONREVISION # DATE

2 02/03/21

2" EXTRUSIONSDETAIL #:

RELEASE:

CI-TL-07-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

VERTICAL JOINT EXTRUSIONS

212" PANEL BASE "A"

EXTRUSIONPART # 2-4046

212" PANEL BASE "C"

EXTRUSIONPART # 2-4054

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

212" SOFFIT EXTRUSION "A"

PART # 2-405721

2" SOFFIT EXTRUSION "B"PART # 2-4061

TWO PIECE OPENINGEXTRUSION CAPPART # 2-4069

212" TWO PIECE OPENING

EXTRUSION BASEPART # 2-4073 PARAPET EXTRUSION

PART # 2-1598

212" CORNER

FEMALE EXTRUSIONPART # 2-3999

212" CORNER

MALE EXTRUSIONPART # 2-4083

SILL EXTRUSIONPART # 2-4064

TOP HAT EXTRUSIONPART # 2-4077

FLUSH INSERTPART # 2-4078

RECESSEDTOP HAT EXTRUSIONPART # 2-4074

RECESSEDINSERTPART # 2-4076

REVISIONREVISION # DATE

2 02/03/21

212" EXTRUSIONS

DETAIL #:

RELEASE:

CI-TL-08-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

VERTICAL JOINT EXTRUSIONS

3" PANEL BASE "A"EXTRUSIONPART # 2-4047

3" PANEL BASE "C"EXTRUSIONPART # 2-4084

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

3" SOFFIT EXTRUSION "A"PART # 2-4058

3" SOFFIT EXTRUSION "B"PART # 2-4062

TWO PIECE OPENINGEXTRUSION CAPPART # 2-4069

3" TWO PIECE OPENINGEXTRUSION BASEPART # 2-4075 PARAPET EXTRUSION

PART # 2-1598

3" CORNERFEMALE EXTRUSIONPART # 2-4000

3" CORNERMALE EXTRUSIONPART # 2-4083

SILL EXTRUSIONPART # 2-4064

TOP HAT EXTRUSIONPART # 2-4077

FLUSH INSERTPART # 2-4078

RECESSEDTOP HAT EXTRUSIONPART # 2-4074

RECESSEDINSERTPART # 2-4076

REVISIONREVISION # DATE

2 02/03/21

3" EXTRUSIONSDETAIL #:

RELEASE:

CI-TL-09-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

VERTICAL JOINT EXTRUSIONS

4" PANEL BASE "A"EXTRUSIONPART # 2-4048

4" PANEL BASE "C"EXTRUSIONPART # 2-4055

OPTIONAL WIPERGASKET

(FIELD INSTALLED)

TOP HAT EXTRUSIONPART # 2-4077

FLUSH INSERTPART # 2-4078

RECESSEDTOP HAT EXTRUSIONPART # 2-4074

RECESSEDINSERTPART # 2-4076

4" SOFFIT EXTRUSION "A"PART # 2-4059

4" SOFFIT EXTRUSION "B"PART # 2-4063

TWO PIECE OPENINGEXTRUSION CAPPART # 2-4069

4" TWO PIECE OPENINGEXTRUSION BASEPART # 2-3515 PARAPET EXTRUSION

PART # 2-1598

4" CORNERFEMALE EXTRUSIONPART # 2-4001

4" CORNERMALE EXTRUSIONPART # 2-4083

SILL EXTRUSIONPART # 2-4064

REVISIONREVISION # DATE

2 02/03/21

4" EXTRUSIONSDETAIL #:

RELEASE:

CI-TL-10-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

LAP STRIPS FOR OUTSIDE CORNER

JAMB EXTRUSION

LAP STRIPS FOR INSIDE CORNER

LAP STRIP FOR PARAPET EXTRUSION

LAP STRIP FOR "J" BASE EXTRUSION

LAP STRIP FOR TWO PIECE

EXTRUSION EXTRUSION

REVISIONREVISION # DATE

0 01/01/21

EXTRUSION LAPSTRIPS

DETAIL #:

RELEASE:

CI-TL-11-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

SILL EXTRUSION

TWO

PIE

CE

JAM

B EX

TRU

SIO

N

TWO PIECE HEAD EXTRUSION

EXPOSED SEALANT(NOT BY KINGSPAN)

FIELD CUT/NOTCH JAMBEXTRUSION(NOT BY KINGSPAN)

FIELD CUT/NOTCH JAMBEXTRUSION AT HEAD ANDJAMB (NOT BY KINGSPAN)

EXPOSED SEALANT(NOT BY KINGSPAN)

SEALANT END DAMUNDER FLEXWRAP

TWO PIECE HEAD EXTRUSION BASE W/FIELD DRILL 3 8" Ø WEEP HOLES(NOT BY KINGSPAN)

EXTRUSION INSTALLATION SEQUENCE:1 TWO PIECE JAMB EXTRUSION BASE2 TWO PIECE HEAD EXTRUSION BASE3 TWO PIECE HEAD EXTRUSION CAP4 TWO PIECE JAMB EXTRUSION CAP5 SILL EXTRUSION6 EXTERIOR SEALANTS AS REQUIRED

TWO PIECE JAMBEXTRUSION BASE

1

6

2

TWO PIECE JAMBEXTRUSION CAP

4

TWO PIECE HEADEXTRUSION CAP

3

TWO PIECE JAMBEXTRUSION CAP

5

REVISIONREVISION # DATE

5 11/30/21

EXTRUSION W/ FLEXWRAP ATFRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-12-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

REVISIONREVISION # DATE

5 11/30/21

SILL EXTRUSION

TWO PIECE HEAD EXTRUSIONTW

O P

IEC

E JA

MB

EXTR

USI

ON

FEMALE EXTRUSION AT HEAD(COMPRESSIBLE FOAM CLOSURENOT SHOWN FOR CLARITY)

CARRY FIELD APPLIED REARSEAL NON-SKINNING BUTYLSEALANT BEAD OVER TOPOF THE FLEXWRAP TAPE

USE DUPONTFLEXWRAP NFTAPE 6" x 6"PATCH

JAMB EXTRUSION,SHINGLE LAPPED

USE DUPONTFLEXWRAP NF

CARRY FIELD APPLIED REARSEAL NON-SKINNING BUTYLSEALANT BEAD OVER TOPOF THE FLEXWRAP TAPE

MALE JAMB EXTRUSIONCUT FOR CLARITY

INTERIOR CAP TRIM

FIELD DRILL 3 8" Ø WEEP HOLES(NOT BY KINGSPAN)

FIELD MITER AT ALLCORNERS(NOT BY KINGSPAN)

EXTRUSION W/ FLEXWRAP ATFRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-13-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

REVISIONREVISION # DATE

5 11/30/21

INTERIOR CAP TRIMSHINGLE LAPPED

TWO PIECE REMOVABLEJAMB TRIM

USE DUPONT FLEXWRAP NFTAPE 6" x 6" PATCHAT ALL CORNERS

DRIP FLASHING

CARRY FIELD APPLIED REAR SEALNON-SKINNING BUTYL SEALANT

BEAD OVER TOP OF THEFLEXWRAP TAPE

BASE TRIM CUT FOR CLARITY

EXTERIOR CAP TRIMCUT FOR CLARITY

TRIM LAP W/ FLEXWRAP ATREMOVABLE FRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-14-KSV

2021

KS SERIES - VERTICAL INSTALLATION

www.kingspanpanels.com

USE DUPONT FLEXWRAP NFTAPE 6" x 6" PATCHAT ALL CORNERS

CARRY FIELD APPLIED REARSEAL NON-SKINNING BUTYL

SEALANT BEAD OVER TOPOF THE FLEXWRAP TAPE

FIELD MITER EXTRUSIONS AT ALL CORNERS

(NOT BY KINGSPAN)

TWO PIECE JAMB EXTRUSIONCUT FOR CLARITY

FIELD DRILL 3 8" Ø WEEP HOLES(NOT BY KINGSPAN)

MALE EXTRUSION CUT FOR CLARITY

REVISIONREVISION # DATE

5 11/30/21

COMPRESSIBLE FOAM CLOSURENOT SHOWN FOR CLARITY

EXTRUSION W/ FLEXWRAP ATREMOVABLE FRAMED OPENING

DETAIL #:

RELEASE:

CI-TL-15-KSV

2021

KS SERIES - VERTICAL INSTALLATION