Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
UP
2
2
REF.
22
UP
UP
UP
DATA
EXISTING LOT AREA
REQUIRED PROPOSED
(MIN) 0.1 ha 5,264.7m² (0.52646 ha)
OCCUPANCY DENSITY
(MAX) 250 / HA 592 / HA WITH ROAD WIDENING
RESIDENTIAL UNITS
SITE DATAZONING BY-LAW: 1108 SECTION 18A (MR-25)
JOHN ST LAND CONEYANCE
KING ST LAND CONEYANCE
45.0 m² (0.0045 ha)
8.5 m² (0.00085 ha)
NEW LOT AREA (POST ROAD WIDEING) (MIN) 0.1 ha 5,182.2 m² (0.51821 ha)
CORNER DAYLIGHT TRIANGLE 29.0 m² (0.0029 ha)
DATA
ZONING
REQUIRED (MIN) PROVIDED
MIN. LOT FRONTAGE (m)
MR-25
0 71.065 m
SE
TB
AC
KS
3.0 m
7.5 m
NORTH EAST YARD BALCONY
SIDE YARD
REAR YARD
TOWER 1
TOWER 2
SETBACKS (SUBJECT TO SPA)
4.7 m
28.8 m
33.2 m
BUILDING HEIGHT 75 m 73.6 m
KIN
G S
TJO
HN
ST
FRONT YARD 5.0 m 5.1 m
KING ST
JOHN ST 0 61.181 m
SE
TB
AC
KS
3.0 m
7.5 m
SIDE YARD
REAR YARD
3.2 m
7.5 m
BUILDING HEIGHT 75 m 70.6 m
KIN
G S
TJO
HN
ST
FLANKAGE
SIDE YARD (PRIVATE LANE)
5.0 m 47.7 m
5.0 m 5.5 m
UNDERGROUND PARKING SETBACK
HOUSE
FLANKAGE
REAR YARD 7.5 m
15.2 m
4.0 m
FRONT YARD (JOHN ST)
PODIUM
FLANKAGE (KING ST)
5.0 m
5.0 m
5.0 m
0.8 m
FRONT YARD (JOHN ST)
FLANKAGE (KING ST)
5.0 m
5.0 m
.8 m
.3 m
CORNER AT KING & JOHN 5.0 m REFER TO PLAN
REAR YARD
SIDE YARD
0
0
0 m
.4 m
SIDE YARD (LANE) COMBINATION OF 10m 1.464 m
REAR YARD 7.5 m BELOW GRADE
5.0 m
7.5 m
NORTH EAST YARD BUILDING 5.1 m5.0 m
DATA
DENSITY (UNITS / HA)
REQUIRED PROPOSED
BUILDING AREA (sq.m.) n/a 782 Sq.m.
250 UNITS / HA (MAX.) = 129
BUILDING COVERAGE (%) n/a 15.1%
NUMBER OF STOREYS 25 22
GROSS BUILDING AREA (sq.m.)Level P1 - Level 22
n/a 17,012.40 Sq.m.
SITE DENSITY
TO
WE
R 1
BUILDING AREA (sq.m.)
BUILDING COVERAGE (%)
NUMBER OF STOREYS
GROSS BUILDING AREA (sq.m.)Level P1- Level 21
TO
WE
R 2
n/a
n/a
25
n/a
782 Sq.m.
15.1%
21
16,444.20 Sq.m.
592 UNITS / HA
NUMBER OF UNITS 160
NUMBER OF UNITS 147
TOTAL NUMBER OF UNITS 307 UNITS (2 TOWERS)
TOTAL NUMBER OF BEDROOMS 468 BEDROOMS (2 TOWERS)n/a
n/a
BUILDING DENSITY
DENSITY COMPARED TO OFFICIAL PLAN 750 BEDROOMS / HA (MAX.)
750 BEDROOMS / HA = 388 903 bedrooms / haBASED ON NEW
LOT AREA
TOTAL UNITS 307
BUILDING COVERAGE n/a 1,796 Sq.m. (34.5%)
LANDSCAPE COVERAGE n/a
HARDSCAPE COVERAGE
NEW LOT AREA
SITE COVERAGE
n/a
2,823 Sq.m. (54.5%)
563 Sq.m. (11%)
5,182 Sq.m. (100%)
DATA
RESIDENTIAL
REQUIRED PROPOSED
PA
RK
ING
SP
AC
ES
TOTAL
BARRIER FREE SPACES 2 + (2% of 275) = 7.5 8
PA
RK
ING
ST
RU
CT
UR
E
(307) x 1 = 307 264
275307
MINIMUM OF 10% PARKING REQUIRED ON SURFACE.
SURFACE = 11 (4%)GARAGE (P1) = 62 (23%)P2 = 99 (36%)P3 = 103 (37%)
PARKING INFORMATION
SURFACE PARKING SPACES 307 x 0.1 = 31 inclusive 11
25% OF GROUND FLOOR TO BE OF HABITABLE AREA
GROUND FLOOR AREA 3759.78 Sq.m.
HABITABLE AREA 990 Sq.m.
PERCENTAGE OF HABITABLE AREA 25% 26.3%
PARKING BREAKDOWN
BICYCLE PARKING139
(LOCATED AT LEVEL 1 IN TOWER 2)
NEW HOUSE LOCATION
KIN
G S
TR
EE
T S
OU
TH
CA
RO
LIN
E S
TR
EE
T S
OU
TH
LOADING / MOVE-INGARBAGE PICKUP
8 SURFACE PARKING
EX
PO
SE
D F
OU
ND
AT
ION
WA
LL
7.7m x 8.8m WNH EASEMENT
LOT BOUNDARY
TO
WE
R L
INKTOWER 2
21 STOREY
TOWER 122 STOREY
ROAD WIDENING
24.720 m
JOHN STREET FRONTAGE
61.181 m
7.62m D
AYLIG
HT
TRIA
NGLE
AMENITY, PARKING BELOW
PR
IVA
TE
LA
NE
BELOW GRADE WNH DUCTBANKSBELOW GRADE WNH DUCTBANKS
6559
802
1464
6712
7620
7620
EXISTING LOADING DOCK / GARBAGE
EXISTING RETAINING WALL
331.937 m 333.884 m
330.769 m
3263
1
A1.9
2
A1.9
3
A1.9
4
A1.9
BLDG SETBACK
5000
5000
3000
BLD
G S
ET
BA
CK
3000
BLDG SETBACK
3000
BLD
G S
ETBAC
K
5000
3 SURFACE PARKING
31970
JOHN STREET WEST
TOWER LINK
BLD
G S
ET
BA
CK
5000
BUILDING LINE @ LEVEL 3 AND ABOVE
5159
7578
TOWER 2 ENTRANCE
3281
3075
LE
VE
LS
1-2
847
57.511m N38°17'30"E
28.6
61m
N
51°5
7'5
0"W
19.354m N38°03'00"E
10.4
45m
N
51°4
8'5
0"W
4.332m N36°35'15"E
R=2.550A=4.077C=3.656
N82°23'10"E
24.9
33m
N
51°3
9'2
0"W
3.550m N36°36'25"E
R=5.476A=5.403C=5.187
N72°18'35"W
82.094m N37°57'45"E
29.9
89m
N
51°4
9'5
0"W
20.910m N54°19'30"W
16.490m N51°49'50"W
5.196m N83°13'50"E
0.420m N38°10'10"E
AREA OF ROAD WIDENING, 8.5 SQ.M.
BLD
G S
ET
BA
CK
7500
ASPHALT
SIDEWALK
SID
EW
ALK
LE
VE
L 1
SID
EW
ALK
SIDEWALK
STAIR
SID
EW
ALK
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BALCONY OVERHEAD
BUILDING SETBACK
BUILDING SETBACK
BUILDING SETBACK
BUILDING SETBACK
BUILDING SETBACK
4727
47421
5515
EXISTING BUILDING - NO. 182
EXISTING BUILDING - NO. 180
EXISTING BUILDING - NO. 176
EXISTING BUILDING - NO. 217
EXISTING BUILDING - NO. 215
EXIST. CONC. DRIVEWAY
SHED
FRAME SHED
SHED
SHED
FRAME GARAGE
SHED
STOOP
6567
9473
71065
1023
282
757
1049
1058
333.900 m
333.900 m
333.900 m
333.900 m
330.775 m
EX. FIRE HYDRANT
EX. FIRE HYDRANT
333.73
333.67
332.95
333.20
332.57
332.27
330.46
330.81
331.23
331.79
3588
331.625 m
BIKE ROOM139 BIKES
SITE
N
KING ST S
UN
ION
BLV
D
UN
ION
ST
E
PARK ST
JOH
N S
T E
JOH
N S
T W
CARO
LINE ST SPARK ST
KIN
G S
TR
EE
T S
JOHN STREET W
CA
RO
LIN
E S
TR
EE
T S
TOWER 1
209 KING
TOWER 2
217 KING
DATA REQUIRED PROVIDED
30 %
LOADING SPACE 1 2
2,823.05 sq.m (54.5%)(NEW LOT AREA)
LANDSCAPE INFORMATION
ASPHALT AT GRADE 408 sq.m.
TOTAL LANDSCAPE AREA(not incl. sidewalks)
PRIVATE AMENITY AREA
PUBLIC PARK AREA
652 sq.m.
1,422 sq.m.
OTHER LANDSCAPE AREA 750 sq.m.
AMENITY INFORMATION
TOWER 1 (INTERIOR)
TOWER 2 (INTERIOR)
TOTAL
REQUIRED PROPOSED
535.4 Sq.m.
1,032.2 Sq.m.
3,831.95 Sq.m.
PODIUM COURTYARD (EXTERIOR) 2,091.55 Sq.m.
STORAGE LOCKERS
TOTAL
PROPOSED
322 HALF HEIGHT LOCKERS
HOUSE (INTERIOR) 172.8 Sq.m.
- MAIN ENTRANCE/ EXIT
SITE LEGEND
- SECONDARY ENTRANCE/ EXIT
- PRIVATE TERRACE ENTRANCE/ EXIT
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Project North True North
Revision No.
As indicated
2017-08-24 10:43:59 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A1.1 - r7
MYV
2017-08-23
SITE PLAN - LEVEL 1
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1 : 2001SITE PLAN - LEVEL 1
N.T.S.
KEY MAP
N.T.S.
SITE ADDRESS
No. Date Revision
1 2015-11-02 ISSUED FOR CITY MEETING
2 2016-01-12 ISSUED TO PLANNER
3 2016-01-27 ISSUED FOR CLIENT MEETING
4 2016-07-07 ISSUED FOR CLIENT REVIEW
5 2017-01-03 ISSUED FOR REVIEW
6 2017-07-05 ISSUED FOR CLIENT REVIEW
7 2017-08-24 ISSUED FOR REZONING
8
UP
UP
UP
LOADING / MOVE-INGARBAGE PICKUP
8 SURFACE PARKING
ACCESS TO TOWER 1 PARKING LEVEL
GARBAGE / RECYCLING
ROOM
GARBAGE PICKUP @ TOWER 2
GARBAGE / RECYCLING
ROOM
EX
PO
SE
D F
OU
ND
AT
ION
WA
LL
22 PARKING STALLSTOWER 2
LOBBY
LEASING OFFICE
LOBBYTRANSFORMER
VAULT
VESTIBULE
RA
MP
DO
WN
T
O P
2
TOWER 1 BACK
ENTRANCE
PROPOSED 7.7m x 8.8m WNH EASEMENT
BELOW GRADE WNH DUCTBANKS
LOT BOUNDARY
30 m
23 m
ACCESS TO TOWER 2 PARKING LEVEL
LINK ABOVE
OVERHEAD ROLLING DOOR
MOVING ROOM
MOVING ROOM
LINE OF DECK ABOVE
40 PARKING STALLSTOWER 1
28892
BELOW GRADE WNH DUCTBANKS
KIN
G S
TR
EE
T S
OU
TH
JOHN STREET WEST
CA
RO
LIN
E S
TR
EE
T S
OU
TH
JOHN ST - FRONTAGE
85.901 m
PR
IVA
TE
LA
NE
1 STEP UP
4 STEPS UP
3 STEPS UP
RAMP UP
330.750 m
330.750 m
330.750 m
330.750 m
330.750 m
330.750 m
330.750 m
330.750 m
331.000 m
331.500 m
331.200 m
330.750 m
331.817 m
3223
1464
1
A1.9
1
A1.9
2
A1.9
2
A1.9
3
A1.9
3
A1.9
4
A1.9
4
A1.9
BLD
G S
ET
BA
CK
5000
BLDG SETBACK
5000
5000
5000
3000
BLD
G S
ET
BA
CK
3000
BLDG SETBACK
3000
7500
BLD
G S
ETBAC
K
5000
3 SURFACE PARKING
9000
9000
43445
35229 6100 35803
330.327 m
4500
1 2
3
4
5
6
7
9
8
10
11
131415161718
20
21
22
23
24
25
26
27
2829
30
31
32
33
34 35
36
37
38
39
40
42
4344
47
48
49
50
51
52
53
54
55
5657
58
59
60
61
62
1354
6252
VISITOR PARKING
VISITOR PARKING
VIS
ITO
R
PA
RK
ING
VIS
ITO
R
PA
RK
ING
2' -
11
1/2
"
1354
1200
45
46
41
MAIL / PARCEL ROOM
140 MAILBOXES
4' -
3 3
/8"5
' - 0
"
22
' - 2
3/8
"
LOADING/ MOVE-IN 3m x
12m
1
34
678
6100
2
5
2800 2400 1500 2400 3638
1200
12000
454
11600
5500
1400
11200
TOWER 1 MAIN ENTRANCE
CONCRETE SIDEWALK
CONCRETE SIDEWALK
1522
1552
DROP CURB
EXISTING LOADING DOCK / GARBAGE
SEE SITE PLAN LEVEL 1 FOR DETAILED AREA
5500 6100 5500 305 5500 6100
6100
6765
12196100
DROP CURB
6100
20 HALF HEIGHT STORAGE UNITS
22 HALF HEIGHTSTORAGE UNITS
LOW HEIGHT LOADING
TOWER 2 ENTRANCE
1656
SID
EW
ALK
SID
EW
ALK
9
10
11
PATH TO TRANSPORT GARBAGE FROM TOWER 1 TO TOWER 2
LIN
K A
BO
VE
SIGN ON DOOR"THIS IS NOT AN EXIT"
12
' - 6
1/2
"
6' - 0"
TERRACE LEVEL GREEN SPACE
LEGEND:
GRADE LEVEL GREEN SPACE
SITE
N
KING ST S
UN
ION
BLV
D
UN
ION
ST
E
PARK ST
JOH
N S
T E
JOH
N S
T W
CARO
LINE ST SPARK ST
KIN
G S
TR
EE
T S
JOHN STREET W
CA
RO
LIN
E S
TR
EE
T S
TOWER 1
209 KING
TOWER 2
217 KING
Lock to Lock Time
Track
Width
:
:
:
feet
6.00
8.04
8.04
13.124.59
21.33
Steering Angle SA:
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Project North True North
Revision No.
As indicated
2017-08-24 10:44:03 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A1.2 - r5
MYV
2017-08-23
SITE PLAN - LEVEL P1
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1:2001SITE PLAN - LEVEL P1
331.60
330.30
333.60
330.40
331.90 334.70
331.30
1 : 4000
KEY MAP
N.T.S.
SITE ADDRESS
1 : 1922GARBAGE TRUCK PROFILE
No. Date Revision
1 2015-11-02 ISSUED FOR CITY MEETING
2 2016-01-27 ISSUED FOR CLIENT MEETING
3 2016-07-07 ISSUED FOR CLIENT REVIEW
4 2017-07-05 ISSUED FOR CLIENT REVIEW
5 2017-08-24 ISSUED FOR REZONING
99 PARKING STALLS
RA
MP
DO
WN
T
O P
3
RAMP UP TO P1
WATERLOO NORTH HYDRO EASEMENT
608
1102
440
1051
1
A1.9
2
A1.9
3
A1.9
4
A1.9
5000
5000
5000
5000
5000
FRONT YARD SETBACK
FLA
NK
AG
E S
ET
BA
CK
1335
1128
1513
1371
1512
MIN. 1100
MIN. 300
MI N
. 8
00
MI N
. 1
00
0
MIN
. 800
6252
1354
1 10
27
35
50
58
34
49
57
65
11
26
66
77
79
7881
80
82
89
90 92
93
99
8800
20 HALF HEIGHT STORAGE UNITS
22 HALF HEIGHT STORAGE UNITS
22 HALF HEIGHT STORAGE UNITS
1200
1200
SERVICES
SERVICES
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Project North True North
Revision No.
1 : 200
2017-08-24 10:44:05 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A1.3 - r4
MYV
2017-08-23
SITE PLAN - LEVEL P2
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1 : 2001SITE PLAN - LEVEL P2
No. Date Revision
1 2016-01-27 ISSUED FOR CLIENT MEETING
2 2016-07-07 ISSUED FOR CLIENT REVIEW
3 2017-07-05 ISSUED FOR CLIENT REVIEW
4 2017-08-24 ISSUED FOR REZONING
1
A1.9
2
A1.9
3
A1.9
4
A1.9
103 PARKING STALLS
20 HALF HEIGHT STORAGE UNITS
WATERLOO NORTH HYDRO EASEMENT
5000
5000
5000
5000
FRONT YARD SETBACK
FLA
NK
AG
E S
ET
BA
CK
608
1102
1335
1128
1513
RAMP UP TO P2
440
1051
MIN. 1100
MIN. 300
MI N
. 1
00
0
MIN
. 800
1
1354
6252
(61
18)
20
' - 0
7/8
"
3000 2800 2800 3000 3000 2800 2800 3000
6100
1656
22 HALF HEIGHT STORAGE UNITS
12
29
37
52
60
36
51
59
67
13
28
68
79
81
8083
82
84
91
92 94
95
101
102 103
88 HALF HEIGHT STORAGE UNITS
13.06m FROM CENTER LINE OF STREET
1512
1200
1200
86 HALF HEIGHT STORAGE UNITS
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Project North True North
Revision No.
1 : 200
2017-08-24 10:44:06 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A1.4 - r4
MYV
2017-08-23
SITE PLAN - LEVEL P3
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1 : 2001SITE PLAN - LEVEL P3
No. Date Revision
1 2016-01-27 ISSUED FOR CLIENT MEETING
2 2016-07-07 ISSUED FOR CLIENT REVIEW
3 2017-07-05 ISSUED FOR CLIENT REVIEW
4 2017-08-24 ISSUED FOR REZONING
Level P1330.750 m
Level 1333.798 m
Level P2327.702 m
Level P3324.654 m
HIGH WATER ELEVATION323.500 m
KING STREET
TERRACE LEVEL
3048
3048
3048
1154
PR
OP
ER
TY
LIN
E
5000 SETBACK
13 16
STORAGE LOCKERS
STORAGE LOCKERS
STORAGE LOCKERS
Level P1330.750 m
Level 1333.798 m
Level P2327.702 m
Level P3324.654 m
HIGH WATER ELEVATION323.500 m
KING STREETSIDEWALK
3048
3048
3048
1154
TERRACE LEVEL
PR
OP
ER
TY
LIN
E
5000 SETBACK
13 16
UNDERGROUND PARKING
UNDERGROUND PARKING
Level P1330.750 m
Level 1333.798 m
Level P2327.702 m
Level P3324.654 m
HIGH WATER ELEVATION323.500 m
MAX. 1100
MIN. 300 KING STREET
3048
3048
3048
1154
GRADE LEVEL
PR
OP
ER
TY
LIN
E
5000 SETBACK
13 16
UNDERGROUND PARKING
UNDERGROUND PARKING
Level P2327.702 m
Level P3324.654 m
HIGH WATER ELEVATION323.500 m
MAX. 1000
MIN. 800 JOHN STREETSIDEWALK
GRADE LEVEL
3048
3048
1154
PR
OP
ER
TY
LIN
E
5000 SETBACK
A KJ L
UNDERGROUND PARKING
UNDERGROUND PARKING
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
1 : 64
2017-08-24 10:44:09 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A1.9 - r1
MYV
2017-08-23
SITE SECTIONS
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1 : 641KING ST SECTION 1
1 : 642KING ST SECTION 2
1 : 643KING ST SECTION 3
1 : 644JOHN ST SECTION
No. Date Revision
1 2017-08-24 ISSUED FOR REZONING
2
2
REF.
22
UP
RELOCATED HOUSE"217 HOUSE"
LINK
OPEN TO BELOW
OPEN TO BELOW
LINK
BIKE ROOM139 BIKES
SOCIAL ROOM
TOUCH DOWN / LOUNGE
BIKE REPAIR AREA
1327.81 SFPARTY ROOM / GAMES ROOM
COURTYARD
COURTYARD
COURTYARD
MEDIA LOUNGE
OVERHEAD DOOR
EXIT @ GRADE TO SIDEWALK
EXIT @ GRADE TO SIDEWALK
ROOF
COURTYARD
ROOF
OPEN TO GARBAGE
ROOM BELOW
(137
2)
4' -
6"
(133
1)
4' -
4 3
/8"
(139
5)
4' -
6 7
/8"
(1524)
5' - 0"
(1524)
5' - 0"
(152
4)
5' -
0"
(1525)
5' - 0"
(154
7)
5' -
0 7
/8"
(152
3)
5' -
0"
(117
1)
3' -
10
1/8
"
(1553)
5' - 1 1/8"
OPEN TO MOVING
ROOM BELOW
OP
EN
TO
VE
ST
. B
ELO
W
BILLIARDS
BBQ AREASUNDECK
FIRE PLACEOUTDOOR LOUNGE
GARDENSOUTDOOR DINING AREA
UNIT B
UNIT BUNIT E
UNIT A
UNIT A-2
UNIT F
spandrel
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Project North True North
Revision No.
1 : 150
2017-08-24 10:44:20 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A2.1 - r5
MYV
2017-08-23
LEVEL 1
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
MYV
1 : 1501LEVEL 1
SUITES SUMMARY - TOWER 1
Level Number of UnitsNumber ofBedrooms Number of Dens Area
Level P3 0 0 0 821 SF
Level P2 0 0 0 821 SF
Level P1 0 0 0 5815 SF
Level 1 6 9 2 7124 SF
Level 2 7 12 5 8418 SF
Level 3 8 12 4 8418 SF
Level 4 8 12 4 8418 SF
Level 5 8 12 4 8418 SF
Level 6 8 12 4 8418 SF
Level 7 8 12 4 8418 SF
Level 8 8 12 4 8418 SF
Level 9 8 12 4 8418 SF
Level 10 8 12 4 8418 SF
Level 11 8 12 4 8418 SF
Level 12 8 12 4 8418 SF
Level 13 8 12 4 8418 SF
Level 14 8 12 4 8418 SF
Level 15 8 12 4 8418 SF
Level 16 8 12 4 8418 SF
Level 17 7 11 4 8053 SF
Level 18 7 11 4 8053 SF
Level 19 7 11 4 8053 SF
Level 20 7 11 4 8053 SF
Level 21 7 11 4 8053 SF
Level 22 0 0 0 2622 SF
160 244 83 183739 SF
SUITES SUMMARY - TOWER 2
Level Number of UnitsNumber ofBedrooms Number of Dens Area
Level P3 0 0 0 3071 SF
Level P2 0 0 0 1942 SF
Level P1 0 0 0 4803 SF
Level 1 0 0 0 6205 SF
Level 2 7 12 5 8418 SF
Level 3 8 12 4 8418 SF
Level 4 8 12 4 8418 SF
Level 5 8 12 4 8418 SF
Level 6 8 12 4 8418 SF
Level 7 8 12 4 8418 SF
Level 8 8 12 4 8418 SF
Level 9 8 12 4 8418 SF
Level 10 8 12 4 8418 SF
Level 11 8 12 4 8418 SF
Level 12 8 12 4 8418 SF
Level 13 8 12 4 8418 SF
Level 14 8 12 4 8418 SF
Level 15 8 12 4 8418 SF
Level 16 8 12 4 8418 SF
Level 17 7 11 4 8053 SF
Level 18 7 11 4 8053 SF
Level 19 7 11 4 8053 SF
Level 20 7 11 4 8053 SF
Level 21 0 0 0 2500 SF
147 224 77 177004 SF
SUITE RATIOS
Residential Unit CountNumber ofBedrooms Number of Dens Area Unit Mix
1 Bedroom Unit
146 146 0 106040 SF 48%
2 Bedroom Unit
1 2 0 1152 SF 0%
2 Bedroom Unit + 1
160 320 160 176079 SF 52%
307 468 160 283271 SF
SUITES- TYPE COUNT
Suite Identifier Area LocationResidentialUnit Count Unit Category
Number ofBedrooms
Number ofDens Area
A Tower 1 75 2 Bedroom Unit + 1 150 1 1075 SF
A Tower 2 71 2 Bedroom Unit + 1 142 1 1075 SF
146 146 292
A-1 Tower 1 1 2 Bedroom Unit + 1 2 1 1075 SF
A-1 Tower 2 1 2 Bedroom Unit + 1 2 1 1075 SF
2 2 4
A-2 Tower 1 1 2 Bedroom Unit + 1 2 1 1155 SF
1 1 2
B Tower 1 75 1 Bedroom Unit 75 0 725 SF
B Tower 2 70 1 Bedroom Unit 70 0 725 SF
145 145 145
C Tower 1 5 2 Bedroom Unit + 1 10 1 1435 SF
C Tower 2 4 2 Bedroom Unit + 1 8 1 1435 SF
9 9 18
D Tower 1 1 2 Bedroom Unit + 1 2 1 1450 SF
D Tower 2 1 2 Bedroom Unit + 1 2 1 1450 SF
2 2 4
E Tower 1 1 2 Bedroom Unit 2 0 1152 SF
1 1 2
F Tower 1 1 1 Bedroom Unit 1 0 897 SF
1 1 1
Total Occurances inDevelopment: 307
307 468
Tower Floorplate Efficiency
Area Category Area Building Efficiency
Circulation / Services 1,217 SF 14%
Residential 7,201 SF 86%
Total 8,418 SF
Project Gross Area
Area Location Area
Podium 2,635 SF
Tower 1 183,739 SF
Tower 2 177,004 SF
Underground Parking 125,997 SF
Total 489,376 SF
No. Date Revision
1 2016-01-27 ISSUED FOR CLIENT MEETING
2 2016-07-07 ISSUED FOR CLIENT REVIEW
3 2017-01-05 REVISED BUILDING LEVELS
4 2017-07-05 ISSUED FOR CLIENT REVIEW
5 2017-08-24 ISSUED FOR REZONING
Level P1330.750 m
Level 1333.798 m
Level 2337.798 m
134579111316 12 26810
Level 3340.897 m
Level 4343.996 m
Level 5347.094 m
Level 6350.193 m
Level 7353.292 m
Level 8356.391 m
Level 9359.490 m
Level 10362.588 m
Level 11365.687 m
Level 12368.786 m
Level 13371.885 m
Level 14374.984 m
Level 15378.082 m
Level 16381.181 m
Level 17384.280 m
Level 18387.379 m
Level 19390.478 m
Level 20393.576 m
Level 21396.675 m
Level 22399.774 m
Level 23400.638 m
Roof403.736 m
7048
65938
4A
5
1
4A
3A
3B
3B
3A
2
2
2
1
1 5 3A
2
5
3B
2
3A
5
4A 4B
1
4A 4B
5
3048
4000
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
864
70446
3B
3A
72986
610
73596
GENERAL ELEVATION NOTES
1. The approved building elevations shall form the basis for the Building Permit Application.
2. Any substantive change(s) or modification(s) to the approved site plan building elevation drawings by the delegated site plan approval authority.
3. All site lighting shall not result in any glare or spill over to surrounding properties or public view.
4. All rooftop mechanical equipment shall be fully screened from public view and surrounding residential properties.
5. Building colours my be subject to minor adjustments in tone and/or shade.
6. Any proposed signage is for illustration purpose(s), and subject to the governing authority Sign By-law.
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
2017-08-24 10:44:32 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A3.1 - r4
MYV
2017-08-23
NORTH ELEVATION
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SB
1:1504NORTH ELEVATION - JOHN ST
EXTERIOR FINISH LEGEND
1
2
3C
3A
3B
4A
4B
5
PRECAST CONCRETE PANEL
COLOUR: CHARCOAL
PREFINISHED METAL PANEL
COLOUR: WHITE
PREFINISHED WINDOWWALL
GLASS TYPE: VISION PANEL
PREFINISHED WINDOWWALL
GLASS TYPE: GLASS SPANDREL PANEL
PREFINISHED WINDOWWALL: OPERABLE AWNINGGLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: GLASS SPANDREL PANEL
BALCONY GUARD
GLASS TYPE: VISION PANEL
No. Date Revision
1 2015-11-02 ISSUED FOR CITY MEETING
2 2017-01-05 REVISED BUILDING LEVELS
3 2017-07-05 ISSUED FOR CLIENT REVIEW
4 2017-08-24 ISSUED FOR REZONING
GENERAL ELEVATION NOTES
1. The approved building elevations shall form the basis for the Building Permit Application.
2. Any substantive change(s) or modification(s) to the approved site plan building elevation drawings by the delegated site plan approval authority.
3. All site lighting shall not result in any glare or spill over to surrounding properties or public view.
4. All rooftop mechanical equipment shall be fully screened from public view and surrounding residential properties.
5. Building colours my be subject to minor adjustments in tone and/or shade.
6. Any proposed signage is for illustration purpose(s), and subject to the governing authority Sign By-law.
Level P1330.750 m
Level 1333.798 m
Level 2337.798 m
1 3 4 5 7 9 11 13 16122 6 8 10
Level 3340.897 m
Level 4343.996 m
Level 5347.094 m
Level 6350.193 m
Level 7353.292 m
Level 8356.391 m
Level 9359.490 m
Level 10362.588 m
Level 11365.687 m
Level 12368.786 m
Level 13371.885 m
Level 14374.984 m
Level 15378.082 m
Level 16381.181 m
Level 17384.280 m
Level 18387.379 m
Level 19390.478 m
Level 20393.576 m
Level 21396.675 m
Level 22399.774 m
Level 23400.638 m
Roof403.736 m
LINE OF GRADE AT ADJACENT 60 UNION BLVD
69938
3962
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
4000
3048
2
2
3B
3A
5
4A
1 4A
5
3B
3A
62840
4000
66840
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
2017-08-24 10:49:39 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A3.2 - r3
MYV
2017-08-23
SOUTH ELEVATION
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SW
1 : 1501SOUTH SITE ELEVATION - ADJACENT TO SUN LIFE
EXTERIOR FINISH LEGEND
1
2
3C
3A
3B
4A
4B
5
PRECAST CONCRETE PANEL
COLOUR: CHARCOAL
PREFINISHED METAL PANEL
COLOUR: WHITE
PREFINISHED WINDOWWALL
GLASS TYPE: VISION PANEL
PREFINISHED WINDOWWALL
GLASS TYPE: GLASS SPANDREL PANEL
PREFINISHED WINDOWWALL: OPERABLE AWNINGGLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: GLASS SPANDREL PANEL
BALCONY GUARD
GLASS TYPE: VISION PANEL
No. Date Revision
1 2017-01-05 REVISED BUILDING LEVELS
2 2017-07-05 ISSUED FOR CLIENT REVIEW
3 2017-08-24 ISSUED FOR REZONING
Level P1330.750 m
Level 1333.798 m
Level 2337.798 m
ABDEGIK CFHJL
Level 3340.897 m
Level 4343.996 m
Level 5347.094 m
Level 6350.193 m
Level 7353.292 m
Level 8356.391 m
Level 9359.490 m
Level 10362.588 m
Level 11365.687 m
Level 12368.786 m
Level 13371.885 m
Level 14374.984 m
Level 15378.082 m
Level 16381.181 m
Level 17384.280 m
Level 18387.379 m
Level 19390.478 m
Level 20393.576 m
Level 21396.675 m
Level 22399.774 m
Roof403.736 m
3962
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
4000
3048
2
2
2
3A
3B
5
4A
1
3B 3A
4B
1A1B
72986
73596
TOWER 1
TOWER 2
GENERAL ELEVATION NOTES
1. The approved building elevations shall form the basis for the Building Permit Application.
2. Any substantive change(s) or modification(s) to the approved site plan building elevation drawings by the delegated site plan approval authority.
3. All site lighting shall not result in any glare or spill over to surrounding properties or public view.
4. All rooftop mechanical equipment shall be fully screened from public view and surrounding residential properties.
5. Building colours my be subject to minor adjustments in tone and/or shade.
6. Any proposed signage is for illustration purpose(s), and subject to the governing authority Sign By-law.
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
2017-08-24 10:54:03 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A3.3 - r3
MYV
2017-08-23
EAST ELEVATION
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SW
1 : 1501EAST SITE ELEVATION - KING ST
EXTERIOR FINISH LEGEND
1
2
3C
3A
3B
4A
4B
5
PRECAST CONCRETE PANEL
COLOUR: CHARCOAL
PREFINISHED METAL PANEL
COLOUR: WHITE
PREFINISHED WINDOWWALL
GLASS TYPE: VISION PANEL
PREFINISHED WINDOWWALL
GLASS TYPE: GLASS SPANDREL PANEL
PREFINISHED WINDOWWALL: OPERABLE AWNINGGLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: GLASS SPANDREL PANEL
BALCONY GUARD
GLASS TYPE: VISION PANEL
No. Date Revision
1 2017-01-05 REVISED BUILDING LEVELS
2 2017-07-05 ISSUED FOR CLIENT REVIEW
3 2017-08-24 ISSUED FOR REZONING
Level P1330.750 m
Level 1333.798 m
Level 2337.798 m
A B D E G I KC F H J L
Level 3340.897 m
Level 4343.996 m
Level 5347.094 m
Level 6350.193 m
Level 7353.292 m
Level 8356.391 m
Level 9359.490 m
Level 10362.588 m
Level 11365.687 m
Level 12368.786 m
Level 13371.885 m
Level 14374.984 m
Level 15378.082 m
Level 16381.181 m
Level 17384.280 m
Level 18387.379 m
Level 19390.478 m
Level 20393.576 m
Level 21396.675 m
Level 22399.774 m
Level 23400.638 m
Roof403.736 m
69888
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
3099
4000
3048
2
2
2
1
1
1
3A
3B
5
4A4B
5
4B
4A
1
5
3B
3A
70446
GENERAL ELEVATION NOTES
1. The approved building elevations shall form the basis for the Building Permit Application.
2. Any substantive change(s) or modification(s) to the approved site plan building elevation drawings by the delegated site plan approval authority.
3. All site lighting shall not result in any glare or spill over to surrounding properties or public view.
4. All rooftop mechanical equipment shall be fully screened from public view and surrounding residential properties.
5. Building colours my be subject to minor adjustments in tone and/or shade.
6. Any proposed signage is for illustration purpose(s), and subject to the governing authority Sign By-law.
ARCHITECTS
LICENCEEDWARD THOMAS
5572
OF
ON
TA
R
IOASSOCIAT
ION
ARCHITECTS INC.
r s m
Do n
ot
scale
dra
win
gs.
Contr
acto
rs m
ust
check a
nd v
erify
all
dim
ensio
ns a
nd r
eport
any
dis
cre
pan
cie
s t
o t
he A
rch
itect
befo
repro
ceed
ing w
ith t
he w
ork
. A
ll docu
ments
rem
ain
the p
ropert
y of
the A
rchite
ct.
Unauth
orize
d u
se,
modifi
catio
n,
and/o
r re
pro
ductio
nof
these d
ocu
ments
is p
roh
ibitt
ed w
ithout
writt
en p
erm
issio
n.
The C
ontr
act
Docum
ents
were
pre
pare
d b
y th
e C
onsulta
nt
for
the
account
of
the O
wner.
The m
ate
rial c
onta
ined h
ere
in r
efle
cts
the C
onsultants
best
judgem
en
t in
lig
ht
of
the info
rmatio
n a
vaila
ble
to h
im a
t th
e t
ime o
f pre
para
tion A
ny
use w
hic
h a
th
ird p
art
y m
akes o
f th
e C
ontr
act
Docum
ents
, or
an
y re
liance o
n o
r decis
ions t
o b
e m
ad
e b
ased
on t
hem
are
the r
espon
sib
ility
of
such t
hird p
art
ies.
T
he C
on
su
ltan
t accepts
no r
espon
sib
ility
for
dam
ages,
if any,
suff
ere
d b
y an
y th
ird p
art
y a
s a
resu
lt of
decis
ions m
ade o
r actio
ns b
ased o
n t
he C
ontr
act
Docum
ents
.
Drawing No.
Status
Drawing Scale
Plot Date / Time
Checked by
Drawn by
Issue Date
Project No
Revision No.
As indicated
2017-08-24 10:59:14 AM
C:\U
se
rs\m
vill
em
aire
\Docum
en
ts\1
502
7_
Site V
9_m
vill
em
aire.r
vt
A3.4 - r3
MYV
2017-08-23
WEST ELEVATION
KING & JOHNREDEVELOPMENT
209 & 217 KING STREETSOUTH, WATERLOO
15027
ISSUED FORREZONING
SW
1 : 1501WEST SITE ELEVATION - CAROLINE ST
EXTERIOR FINISH LEGEND
1
2
3C
3A
3B
4A
4B
5
PRECAST CONCRETE PANEL
COLOUR: CHARCOAL
PREFINISHED METAL PANEL
COLOUR: WHITE
PREFINISHED WINDOWWALL
GLASS TYPE: VISION PANEL
PREFINISHED WINDOWWALL
GLASS TYPE: GLASS SPANDREL PANEL
PREFINISHED WINDOWWALL: OPERABLE AWNINGGLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: VISION PANEL
PREFINISHED STOREFRONT SYSTEM
GLASS TYPE: GLASS SPANDREL PANEL
BALCONY GUARD
GLASS TYPE: VISION PANEL
No. Date Revision
1 2017-01-05 REVISED BUILDING LEVELS
2 2017-07-05 ISSUED FOR CLIENT REVIEW
3 2017-08-24 ISSUED FOR REZONING