4
CONFORMITY Klaus Multiparking GmbH Hermann-Krum-Straße 2 D-88319 Aitrach Phone +49-7565-508-0 Fax +49-7565-508-88 E-Mail [email protected] Internet www.multiparking.com Page 1 Section Dimensions Car data Page 2 Recess plans Page 3 Electrical data Technical data Page 4 To be perfor- med by the customer Description Page 1 of 4     T    u    r    n    t    a     b     l    e        D       4       5       0     |     C    o     d    e    n    u    m     b    e    r    5    8    3  .    9    1  .    7    4    0   -    0    0    2      |     V    e    r    s     i    o    n    1    0  .    2    0    0    9 Product Data Turntable D450 Dimensions: All space requirements are minimum nished dimensions. Tolerances for space requirements . Dimensions in cm. +3 0         3         2   .         5 Turntable: Ø 450 Center bearing; dowelled; length of dowel: 10 cm Required space: min. Ø 550 (in case of vehicle length 500  ) Drive unit 0.37 kW 80         1         0 Drainage Ø 4 Conduit EN 25 (M25) with taut wire Fixed part Turning part Top edge finished floor Turntable D450 (below oor level) Turntable D450 (above oor level)         2         2   .         5 80         1         0 Top edge finished floor Top edge nished oor: T olerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 18202, chart 3, line 3. max. 5.00 m width Car dimensions max. 2500 kg weight max. 625 kg wheel load Suitable for: Standard passenger car and station wagon. Standard passenger cars are vehicles without any sports options such as spoilers, low-prole tyres etc.

Kalus Multi Parking - Turntable Datasheet

Embed Size (px)

Citation preview

8/3/2019 Kalus Multi Parking - Turntable Datasheet

http://slidepdf.com/reader/full/kalus-multi-parking-turntable-datasheet 1/4

CONFORMITY

Klaus Multiparking GmbHHermann-Krum-Straße 2D-88319 Aitrach

Phone +49-7565-508-0

Fax +49-7565-508-88

E-Mail [email protected] www.multiparking.com

ge 1

ction

mensions

r data

ge 2

cessns

ge 3

ctricalta

chnicalta

ge 4

be perfor-d by the

stomer

scription

Page 1 of 4

    T   u   r   n   t   a    b    l   e       D      4      5      0    |    C   o    d   e   n   u   m    b   e   r   5   8   3 .   9   1 .   7   4   0  -   0   0   2     |

    V   e   r   s    i   o   n   1   0 .   2   0   0   9

Product Data

Turntable

D450

Dimensions:

All space requirements are minimumfinished dimensions. Tolerances for spacerequirements . Dimensions in cm.+3

0        3        2  .

        5

Turntable: Ø 450

Center bearing; dowelled;length of dowel: 10 cm

Required space: min. Ø 550 (in case of vehicle length 500 )

Drive unit 0.37 kW80

        1        0

Drainage Ø 4

Conduit EN 25 (M25) with taut wire

Fixed part

Turning part

Top edgefinishedfloor

Turntable D450 (below floor level)

Turntable D450 (above floor level)

        2        2  .

        5

80

        1        0

Top edgefinishedfloor

Top edge finished floor:Tolerances for the evenness of thecarriageway must be strictly compliedwith in accordance with DIN (= GermanIndustrial Standard) No. 18202, chart 3,line 3.

max. 5.00 mwidth

Car dimensions

max. 2500 kg weight

max. 625 kg wheel load

Suitable for:Standard passenger car and station wagon.

Standard passenger cars are vehicleswithout any sports options such asspoilers, low-profile tyres etc.

8/3/2019 Kalus Multi Parking - Turntable Datasheet

http://slidepdf.com/reader/full/kalus-multi-parking-turntable-datasheet 2/4

Turntable D450 | Code number 583.91.740-002 | Version 10.2009

ge 1

ction

mensions

r data

ge 2

cessns

ge 3

ctricalta

chnicalta

ge 4

be perfor-d by the

stomer

scription

Page 2 of 4

Recess plan for turntables with drive unit above floor level

Recess plan for turntables with drive unit below floor level

        3        2  ,

        5

480

80

        1        0

Conduit EN 25 (M25) with taut wire

Drainage Ø 4

        2        0

        4        0

        4        8        0

        1        9        9

Drainage Ø 4

ConduitEN 25 (M25)with taut wire

      +        1  ,

        5      +        1  ,

        5

        5        0

        2        2  .

        5

80

        1        0

Conduit EN 25 (M25) with taut wire

Drainage Ø 4

        1        0

      +        1  .

        5

For turntables above floor level only the shaft for the drive unit is required (80 x 50 x 22.5 )

8/3/2019 Kalus Multi Parking - Turntable Datasheet

http://slidepdf.com/reader/full/kalus-multi-parking-turntable-datasheet 3/4

Turntable D450 | Code number 583.91.740-002 | Version 10.2009

ge 1

ction

mensions

r data

ge 2

cessns

ge 3

ctricalta

chnicalta

ge 4

be perfor-d by the

stomer

scription

Page 3 of 4

Technical data

– maintenance offer/contract– declaration of conformity

 Available documents

Environmental conditions for the area of multiparking systems:Temperature range –10 to +40° C. Relative humidity 50 % at amaximum outside temperature of + 40° C.

Environmental conditions

See separate sheet regarding corrosion protection.

Corrosion protection

Ball bearing of the rollers provide a low sound level.

Noise emission

Electrical data

– Supply line 5 x 1.5 mm2 ( 3 PH+ N+ PE) to the main cabinet withlockable main switch. It is possible, that special laying systemand big length of the cable necessitate larger cable. The electricinstallation must correspond to the local standards.

– Main fuse:3 x fuse 10 A (slow) or circuit breaker 3 x 10 A (trigger characteristicK or C).

– The supply line to the main cabinet must be provided by thecustomer during installation. The functionality can be monitoredon site by our fitters together with the electrician. If this cannotbe done during installation for some reason for which the customeris responsible, the customer must commission an electrician attheir own expense and risk.

Electrical supply

Easy-to-survey positioning (e.g. on column).

Protection against unauthorized use.

May also be recessed in wall if required.

Operating device

– Max. load: cars and small trucks up to 2,500 kg

– It is prohibited to work on vehicles that are currently parked onthe turntable

– The parked vehicle must be protected against unintentionalmovement, in accordance to the operating instructions

– The transport of any persons on the turntable is only permittedwhen seated inside the vehicle

Notes

8/3/2019 Kalus Multi Parking - Turntable Datasheet

http://slidepdf.com/reader/full/kalus-multi-parking-turntable-datasheet 4/4

Turntable D450 | Code number 583.91.740-002 | Version 10.2009

ge 1

ction

mensions

r data

ge 2

cessns

ge 3

ctricalta

chnicalta

ge 4

be perfor-d by the

stomer

scription

Page 4 of 4

Description

We reserve the right to change this specification without further notice

The rotor consists of individual segments that are screwed togetherto form a solid frame. This frame is equipped with central ball bearingsand (in accordance to the static requirements for coverage) maintenance-free rollers with ball bearings, which allow low-noise movement of theturntable.

These rollers are placed on the circular U-profile frame, which is mountedsecurely to the floor using dowelled joints. Additional concrete bracketsare welded to the sides.

General description

– The turntable is driven by a three-phase geared motor using frictionalresistance ( 0.37 kW, IP 55, 400 V, 50 Hz)

– In 45 seconds, the table rotates 1 x 360° (n = 1.33/min)– In the event of a power failure, the turntable can be rotated manually

by releasing the motor brake– The motor is supported in a special compensator with adjustable

contact pressure– Specifications regarding the enclosure size for the motor and the

ductwork that must be setup by the customer can be foundon page 2

Drive

– A push-button is used for operation in dead man’s control– The power feed supplied by the customer can be interrupted

using a lockable main switch

Operation

– The floor cover is made of galvanized corrugated sheet metal– A cover is built-in at the appropriate location for installation andmaintenance work

– Screws, nuts and plates are galvanized– All other steel and sheet metal parts are hot-galvanized with

exception of construction-related parts such as bolts, bearings, etc.

Floor cover 

– The weight of the entire turntable is approximately 1,500 kg– The turntable has a diameter of 450 cm

Weight

– 2-channel radio remote control– Proximity switch (radar)– Safety light barriers (infrared)

Options

The Klaus company reserves the right in the course of technical progress to use newer or other technologies, systems, processes, proceduresor standards in the fulfillment of their obligations other than those originally offered provided the customer derives no disadvantage fromtheir so doing.

To be performed by the customer 

Lockable main switch per main cabinet. The lockable main switch isto be mounted directly next to the main cabinet.

Main switch

Recess for drive motor and turntable, drainage of the recess.

Recess

Embedding in concrete.

Embedding 

Optionally required drainage.

Drainage

Conduit EN 25 (M25) with taut wire between the drive pit and themain cabinet.

Conduit

The supply line to the main cabinet must be provided by the customerduring installation. The functionality can be monitored on site by ourfitters together with the electrician. If this cannot be done duringinstallation for some reason for which the customer is responsible,the customer must commission an electrician at their own expenseand risk.

Electrical supply to the main cabinet

– Costs for final technical approval by an authorized body

If the following are not included in the quotation, they will alsohave to be provided / paid for by the customer:

Lighting, ventilation, fire extinguishing and fire alarm systems.

Building services