1
Safe Operation 1. Check the rating label for voltage and frequency before connecting this luminaire to the electrical supply. 2. Ensure that the supply is switched off when working on this luminaire, whether installing, re-lamping or carrying out any other servicing. 3. Use the correct lamps as initially supplied or as indicated on the ballast label. 4. This luminaire is suitable for direct mounting on all non-combustible and normally flammable materials, e.g. timber, plasterboard. Do not mount luminaire on or close to readily flammable materials. 5. To prevent damage to H.F. Ballasts do not mix H.F. and Conventional Magnetic Ballasts (Switch, Quick or S.R Start) on the same electrical circuit. 6. Where use in more onerous situations is required, e.g. In part-completed buildings before “drying-out” is completed, or areas where ambient temperatures are outside the normal temperature range, then consult our Sales Office. Servicing and Disposal 1. At commissioning and handing over of installation ensure that a copy of these instructions are presented to the authority responsible for the operation and maintenance of the luminaire. 2. Servicing, e.g. cleaning, lamp replacement, must only be carried out after the electricity supply has been switched off. It must not be assumed that luminaires with lamps not lit are switched off - always check before servicing. 3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that will impair the thermal safety or optical performance of the luminaire is maintained. 4. Failed lamps and starter switches must be replaced as soon as practicable by lamps and starters of the same type. For electronic start circuits allow one minute for the thermal cut-out to re-set before switching on the mains supply. 5. At the end of life the lamp and luminaire are classed as WEEE under directive 2002/96/EC and should be disposed of in accordance with local legislation. Diffuser/controller attachments Complete diffuser/controller assembly by firmly pressing home endplates onto diffuser. Metal reflector, with wireguard attachments Single lamp fit support brackets to channel cover fixing screws. Fit diffuser to support brackets. Twin lamp fit support brackets to channel cover fixing screws. Fit diffuser ensuring that diffuser edge engages in anti-lift notches. Remove protective film from specular insert. Fit reflector housing to channel cover fixing screws and insert lamp(s). Lift and tilt panel or louvre into position as shown. Fix support straps inside reflector using the 4mm dia holes provided. Attach reflector to luminaire and insert lamps. Centralise guard longitudinally, hook one side into support straps and tighten screws to retain. Swing other side of guard and locate in support strap hooks. Tighten screws to retain. Fit wireguard bracket assembly to channel cover fixing screws and slacken clamp bracket screws. Hook one side of wireguard onto bracket and centralise longitudinually. Swing up other side into position and tighten screws to retain. Unscrew and remove geartray cover Fixing Details These luminaires comply with BSEN60598-1 and are suitable for use in normal indoors conditions. o o Approved normal ambient temperature range: 5 C to 25 C. Installation notes a) Ballasts comply with BS2818 but the surface temperature of ballast castings may damage standard insulation o cables. Where supply cables run adjacent to ballast casings, use cable rated at not less than 150 C (BS6500, type E12) or alternatively protect standard insulation cables with heat resistant sleeving. b) When 20mm conduit bush fixing is used, place an adequately sized steel washer between inside of channel and bush. When small head fixing screws are used fit washers or slip-fix platese. c) 20mm knockouts are provided in channel endplates. For surface conduit end entry fit hexagonal male bush from inside of luminaire channel. d) Mounting in-line. For use with diffusers/controllers space battens at least 15mm apart. For bare battens (or with reflectors) may butt up together. e) On luminaires where gear is mounted on a seperate geartray, access to the besa entry and fixing points can be gained by removing the geartray. Hold channel to fixing surface and screw to secure (525mm on 600mm/2ft Battens) C L 600mm Connect supply to 3-way terminal, block marked, L, N and E Wiring Details NOTE: Ensure lampholders with yellow wires are holding the same lamp LUMINAIRES MUST BE EARTHED N L - Blue - Green/Yellow - Brown Place geartray cover back into position and screw to lock into place Insert lamp/s o 90 Slide lampholders into position, ensuring they are registered against the back stop in the endcap Single Twin 6 7 8 9 10 11 1 2 3 4 5 Instruction Leaflet K820V4 T8 Batten Range January 2016 K820V4 Eaton Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB Sales T: +44 (0)1302 303303 F: +44 (0)1302 367155 E: [email protected] General +44 (0)1302 321541 +44 (0)1302 303220 [email protected] International Sales +44 (0)1302 303250 +44 (0)1302 303251 [email protected] Instruction Manual - K820V4 January 2016 T8 Batten Range 20mm

K820V4 January 2016 T8 Batten Range...January 2016 T8 Batten Range 20mm Title Crompack 5 - Installation sheet Subject Installation instructions for Eaton's Crompack 5 surface and suspended

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: K820V4 January 2016 T8 Batten Range...January 2016 T8 Batten Range 20mm Title Crompack 5 - Installation sheet Subject Installation instructions for Eaton's Crompack 5 surface and suspended

Safe Operation

1. Check the rating label for voltage and frequency before connecting this luminaire to the electrical supply.2. Ensure that the supply is switched off when working on this luminaire, whether installing, re-lamping or carrying out any other servicing.3. Use the correct lamps as initially supplied or as indicated on the ballast label.4. This luminaire is suitable for direct mounting on all non-combustible and normally flammable materials, e.g. timber, plasterboard. Do not mount luminaire on or close to readily flammable materials.5. To prevent damage to H.F. Ballasts do not mix H.F. and Conventional Magnetic Ballasts (Switch, Quick or S.R Start) on the same electrical circuit.6. Where use in more onerous situations is required, e.g. In part-completed buildings before “drying-out” is completed, or areas where ambient temperatures are outside the normal temperature range, then consult our Sales Office. Servicing and Disposal

1. At commissioning and handing over of installation ensure that a copy of these instructions are presented to the authority responsible for the operation and maintenance of the luminaire.2. Servicing, e.g. cleaning, lamp replacement, must only be carried out after the electricity supply has been switched off. It must not be assumed that luminaires with lamps not lit are switched off - always check before servicing.3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that will impair the thermal safety or optical performance of the luminaire is maintained.4. Failed lamps and starter switches must be replaced as soon as practicable by lamps and starters of the same type. For electronic start circuits allow one minute for the thermal cut-out to re-set before switching on the mains supply.5. At the end of life the lamp and luminaire are classed as WEEE under directive 2002/96/EC and should be disposed of in accordance with local legislation.

Diffuser/controller attachmentsComplete diffuser/controller assembly by firmly pressing home endplates onto diffuser.

Metal reflector, with wireguard attachments

Single lamp fit support brackets tochannel cover fixing screws. Fit diffuserto support brackets.

Twin lamp fit support brackets to channel cover fixing screws. Fit diffuserensuring that diffuser edge engages inanti-lift notches.

Remove protective film from specularinsert. Fit reflector housing to channelcover fixing screws and insert lamp(s).Lift and tilt panel or louvre into positionas shown.

Fix support straps inside reflector usingthe 4mm dia holes provided. Attachreflector to luminaire and insert lamps.

Centralise guard longitudinally, hookone side into support straps and tightenscrews to retain. Swing other side of guard and locate in support straphooks. Tighten screws to retain.

Fit wireguard bracket assembly tochannel cover fixing screws andslacken clamp bracket screws. Hookone side of wireguard onto bracket andcentralise longitudinually. Swing up other side into position and tightenscrews to retain.

Unscrew and remove geartray

cover

Fixing Details

These luminaires comply with BSEN60598-1 and are suitable for use in normal indoors conditions.o oApproved normal ambient temperature range: 5 C to 25 C.

Installation notes

a) Ballasts comply with BS2818 but the surface temperature of ballast castings may damage standard insulation o cables. Where supply cables run adjacent to ballast casings, use cable rated at not less than 150 C (BS6500,

type E12) or alternatively protect standard insulation cables with heat resistant sleeving.b) When 20mm conduit bush fixing is used, place an adequately sized steel washer between inside of channel and bush. When small head fixing screws are used fit washers or slip-fix platese.c) 20mm knockouts are provided in channel endplates. For surface conduit end entry fit hexagonal male bush from inside of luminaire channel.d) Mounting in-line. For use with diffusers/controllers space battens at least 15mm apart. For bare battens (or with reflectors) may butt up together.e) On luminaires where gear is mounted on a seperate geartray, access to the besa entry and fixing points can be gained by removing the geartray.

Hold channel tofixing surface and screw to secure

(525mm on 600mm/2ft Battens)

CL

600mm

Connect supply to3-way terminal,block marked,

L, N and E

Wiring Details

NOTE: Ensure lampholders with yellow wires are holding

the same lamp

LUMINAIRES MUST BE EARTHED

N

L

- Blue- Green/Yellow- Brown

Place geartray cover back into position and

screw to lock into place

Insert lamp/s

o90

Slide lampholders into position, ensuring they are registered against the back stop in the

endcap

Single

Twin

6 7 8

9 10 11

1 2 3

4 5

Instruction Leaflet K820V4

T8 Batten RangeJanuary 2016

K820V4

Eaton Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NBSales T: +44 (0)1302 303303 F: +44 (0)1302 367155 E: [email protected]

General +44 (0)1302 321541+44 (0)1302 [email protected]

International Sales +44 (0)1302 303250+44 (0)1302 [email protected]

Instruction Manual - K820V4January 2016

T8 Batten Range

20mm