IS:3017 1985
Indian Standard
SPECIFICATION FOR
THERMOSTATS FOR USE WITH
ELECTRIC WATER HEATERS
Fi rst Rev i si on )
Electrical Appliances Sectional Committee ETDC 43
Chairman
SHRI A. N. GROSH
Members
Representing
Development Commissioner, Small Scale Industries
( Ministry of Industry ), New Delhi
SRRI A. BANDOPADHYA ( Alternate to
Shri A. N. Ghosh )
SHRI G. K. AITHAL
Bajaj Electricals Ltd. Bombay
BRIG M. L. ANAND
Consumer Council of India, New Delhi
8/16/2019 IS 3017
3/25
IS: 3017 1985
( Continued frompuge
1 )
Mmnbars
SHRI V. K. KAPUR
Repres ing
Director of Industries, Delhi Administration, New
Delhi
SHRI O.P.
SA~HDE~A Alternate)
SHRI G.
L. KESWANI Directorate General of Technical Development,
New Delhi
SRRI KULXOHAN SINQH
Director of Industries, Government of Haryana,
Chandigarh
SHRI
0.
P. BEHL (
Alternate )
SRRI
G.
D. PATIL
Elpro International Ltd, Pune
SERI
H. L. DHAM ( Alternote )
SERI RAJINDER NATH
C. La1 Electricals Mechanicals, Ambala
Sam SATISH CHANDER ( Alternate )
SIIRI
K. P. SETHI
Racold Appliances Pvt Ltd, Pune
SHRI V. K. MANCHANDA ( Alternate )
SHRI
R. N.
SOPdAI
Rallis India Ltd, Bombay
SRRI V. R. DARSHINAMURTHY ( Ahwnatc )
SHRI T. SOMASUNDARAM Department of Industries and Commerce,
SHRI M. RAJAQOPALAN (
kltcmatc)
Government of Tamil Nadu, Madras
RID. SUDHAKAR REDDY
Tamil Nadu Electrical Appliances Manufacturers’
Association, Madras
DR R. RAMARATHANAI~ ( Altcrnatc )
8/16/2019 IS 3017
4/25
IS:3017 1985
Indian Standard
SPECIFICATION FOR
THERMOSTATS FOR USE WITH
ELECTRIC WATER HEATERS
Fi rst Rev i si on )
0. FOREWORD
0.1 This Indian Standard ( First Revision ) was adopted by the Indian
Standards Institution on 28 August 1985, after the draft finalized by the
Electrical Appliances Sectional Committee had been approved by the
Electrotechnical Division Council.
8/16/2019 IS 3017
5/25
IS:3017 -1985
provisions of the clause apply ) or not applicable and the sub-clauses or
portions thereof which are not applicable are indicated as under:
a) In case of a clause where it is applicable or not applicable, the
wording used is
“This clause of IS : 30 1979* is applicable/not
applicable”.
b) In case of a sub-clause or part thereof ‘Not applicable’.
Wherever a sub-clause of IS : 302-1979* is to be replaced by a new
text, it has been indicated as under:
‘Replacement - followed by the new text’.
Any addition to the existing provisions of a sub-clause of
IS : 302-1979* has been indicated as under:
‘Addition - followed by the text of the additional matter’.
Clauses/tables which are additional to those of IS : 302-1979” are
numbered starting from 101 and additional sub-clauses are numbered
with the main clauses number followed by 101, 102, etc, for example
7.101.
Additional appendices have been numbered starting from AA.
8/16/2019 IS 3017
6/25
IS : 3017 - 1985
1. SCOPE
This
clause
of IS
: 302-1979*
is applicable except as follows:
1.1 Replacement
This standard covers the general, safety and performance require-
ments of thermostats of the stem type for use with electric immersion
water heaters electric instantaneous water heaters and electric storage
type water heaters intended for use on ac circuits at voltages not
exceeding 250 V and current rating not exceeding
25
A.
1.2
Replacement
The
standard does not cover the thermostats for use with other
electric appliances.
2.
TERMINOLOGY
This clause of IS
:
302-1979” is applicable except as follows:
2.4,2.8,2.9 to 2.11, 2.17 to 2.19,2.21 to 2.25, 2.28, 2.30, 2.31, 2.38
8/16/2019 IS 3017
7/25
ES:3017 1985
2.108 Differential -
The difference between the temperature at which
the “contacts open and the temperature at which they close under the
specified conditions of test.
2.169 Indicated Temperature
- The temperature indicated by the
knob or pointer on the scale of an adjustable or pre-set thermostat or the
temperature marked on a non-adjustable thermostat.
3. GENERAL REQUIREMENT
This clause of IS
: 302-1979*
is
applicable except as follows:
3.1 Para 2 not applicable.
4. GENERAL NOTES ON TESTS
This clause of IS : 302-1979’ is applicable except as follows:
4.1 Notes 3 to 5 not applicable.
4.2 Addition
The water immersion test ( 15.2.4 ) shall be carried out on two
additional samples.
4.7 to 4.9 and 4.12 to 4.14 not applicable.
8/16/2019 IS 3017
8/25
IS : 3017 - 1985
NOTE 5 -
For the purposes of this standard, unenclosed thermostats are considered
to be ordinary thermostats. It is. however, understood that a higher degree of
protection against moisture may be obtained when the themostat is mounted in the
appliance.
6.1 c) According to the temperature differential
1) Class 1 - Thermostats having temperature differential not
exceeding 5X,
2) Class 2 -
Thermostats having temperature differential exceeding
5°C but not exceeding 10°C.
7.
MARKING
This clause of IS : 302-1979* is applicable except as follows:
7.1 Replacement
The following information shall be marked on the outer visible
surface
stat:
a)
b)
c)
or on a label firmly attached to the switch head of the thermo-
Name or registered trade-mark of the manufacturer;
Type number, model number and serial number, if any;
Rated voltage in volts and current in amperes;
8/16/2019 IS 3017
9/25
IS:3011 - 1985
9. STARTING OF MOTOR OPERATED APPLIANCES
This clause of IS : 302-1979* is not applicable.
16.
INPUT AND CURRENT
This clause of IS : 302-1979: is not applicable.
11. TEMPERATURE-RISE
This clause of IS : 302-1979* is applicable except as follows:
11.2
Replacement
The thermostat is set at its highest setting and is mounted in a
suitable enclosure so that the temperature of the stem differs from the
temperature set on the thermostat by 5 f 1°C and the contacts are in
the closed position but as near the point of opening as possible.
11.4 to 11.6 not applicable.
11.7 Replacement
The thermostat is operated at the rated voltage and rated current
till the steady state conditions are established.
8/16/2019 IS 3017
10/25
14.RADIO AND TELEVISION INTERFERENCE
This clause of IS
:
302-1979” is not applicable.
15.
MOISTURE RESISTANCE
IS
:
3017 - 1985
SUPPRESSION
This clause of IS
:
302-1979” is applicable except as follows:
15.2.1 to 15.2.3 not applicable.
15.2.4 Replacement
This test is carried out on the two additional samples of thermostats.
The thermostat is immersed in water up to the stem length at a
temperature of 27 5 2°C.
After i. hour of immersion, the thermostat is removed from water
and dried, care being taken to ensure that all the moisture is removed
from the insulation in the vicinity of the terminals.
The leakage current
is then measured as described in 16.2.
The leakage current shall not
exceed the value specified in 13.2.
The treatment described above and the measurement of the leakage
current are made five times after whioh the sample shall withstand the
electric strength test as specified in 16.4, the test voltage being reduced to
1 000 V.
15.3 Not applicable.
16. INSULATION RESISTANCE AND ELECTRIC STRENGTH
AFTER HUMIDITY TREATMENT )
8/16/2019 IS 3017
11/25
IS:3017- 1985
The test voltage is 1.06 times the rated voltage, or 1.06 times the
upper limit of the rated voltage range for appliances for dc only, for
single-phase appliances and for three-phase appliances which are also
suitable for single-phase supply, if the rated voltage or the
upper
limit
of the rated voltage range does not exceed 250 V.
The leakage current measured after the application of the test
voltage shall not exceed the value given in 13.2.
16.3 Not applicable.
16.4 Para
1 Replacement
Immediately after the test given in 16.2, the insulation is subjected
for 1 minute to a voltage of substantially sine-wave form having a
frequency of 50 or 60 Hz.
The value of the test voltage and the points
of application are shown in the following table.
17.
OVERLOAD PROTECTION
This clause of IS : 302-1979* is not applicable.
18. ENDURANCE
8/16/2019 IS 3017
12/25
IS: 3017 -1985
19.
20.
21.
22.
not
ABNORMAL OPERATION
This clause of IS
: 302-19?9*
is not applicable.
STABILITY AND MECHANICAL HAZARDS
This clause of IS
:
302-1979” is not applicable.
MECHANICAL STRENGTH
This clause of IS
:
302-1979* is applicable.
CONSTRUCTION
This clause of IS
: 302-1979*
is applicable except as follows:
22.4, 22.9 to 22.12, 22.15 to 22.18, 22.20, 22.23 to 22.30 and
applicable.
22.32
Additional sub-clauses
22.101
Provision for Attaching to Appliances -
A spring clip-to-
8/16/2019 IS 3017
13/25
IS : 3617 - 1985
24. COMPONENTS
This clause of IS
:
3021979* is applicable except as follows:
24.2 and 24.4 to 24.10 not applicable.
25. SUPPLY CONNECTIONS AND EXTERNAL FLEXIBLE
CABLES AND CORDS
This clause of IS : 302-1979” is applicable except as follows:
25.3 to 25.14 not applicable.
26. TERMINALS FOR EXTERNAL CONDUCTORS
This clause of IS : 302-1979* is applicable.
27. PROVISION FOR EARTHING
This clause of IS : 3021979* is applicable except as follows:
27.3 Not applicable.
27.5 Para 1 Replacement
The earth resistance shall be less than 0’1 ohm:
8/16/2019 IS 3017
14/25
IS I 3017 - 1985
33. FINISH
This clause of IS
:
302-1979* is applicable except
as
follows:
33.1
Replacement
The .external finish used on metal components shall be of a heat and
moisture resisting nature and shall not be adversely affected by variations
in temperature under normal operating conditions or
during the
endurance test.
33.2 Not applicable.
Additional clauses
101. DIMENSIONS
101.1 To facilitate interchangeability between different makes, the
preferred dimensions ( see Fig. 101 ) should be as given in 101.2 to 101.4
( see also 0.4 ).
8/16/2019 IS 3017
15/25
IS : 3017 - 1985
101.2 Stem - The nominal stem length if measured from the tip of
the switch head shall be 175,275 or 450 mm. The outer diameter of
the stem shall be 8 mm. The stem shall be uniform in diameter and
straight so that it passes freely into a full length gauge of 8.5 mm internal
diameter.
101.3 Switch Head
101.3.1 The height of the switch head including any projections, shall
not exceed 50 mm.
101.3.2 For rectangular type switch heads, the length and breadth
shall not exceed 55 mm and 40 mm respectively. The horizontal
distance between the centre of the stem and any point of the switch head
including terminal projection shall not exceed 50 mm.
101.3.3 For circular type switch heads, the diameter shall not exceed
55 mm including terminal projections, if any.
101.4 Spring Clip - The spring clip shall be designed to clip firmly
over a collar of 25 mm diameter.
8/16/2019 IS 3017
16/25
IS : 3017 -
1985
104.1 Type Tests -
The tests specified in Table 101 shall constitute the
type tests and shall be carried out on two samples of thermostats of the
same type and rating selected preferably at random from a regular
production lot. Before commencement of the tests, the thermostats
shall be visually examined and inspected for obvious visual defects
in respect of components, parts and their assembly construction, stability
markings, provision of suitable terminals for supply connection, earthing
and the effectiveness of screws and connections.
The external surface
finish shall be even and free from finishing defects.
TABLE 101 SCHEDULE OF TYl’E TESTS
SL
TEST
No.
1) 2)
i) Protection against electric shock
ii) Temperature-rise
CLAUDE: RETERPXO
3)
8
11
8/16/2019 IS 3017
17/25
IS : 3017 - 1985
104.1.1
Criteria of Acceptance -
Both samples shall successfully pass all
the type tests for proving conformity with the requirements of the
standard.
If any of the samples fails in any of the type tests, the testing
authority, at its discretion may call for fresh samples not exceeding
twice the original number and subject them again to all tests or to the
test(s) in which failure(s) occurred.
No failure shall be permitted in the
repeat test(s).
104.2 Acceptance Tests - The following
shall constitute the
acceptance tests:
.
Test
a>
b)
4
Protection against electric shock
Temperature-rise
Insulation resistance and electric strength at
operating temperature
Moisture resistance
Insulation resistance and electric strength
( after humidity treatment )
Clause Reference
8
11
13
4
4
15
16
8/16/2019 IS 3017
18/25
18:3017 1985
APPENDIX A
TABLES OF TYPE TESTS
This Appendix of IS : 302-1979* is not applicable.
APPENDIX B
( Clawe 104.2.1 )
SAMPLING PROCEDURE FOR ACCEPTANCE TESTS
This Appendix of IS : 302-1979’ is applicable as indicated in 104.2.1.
APPENDIX C
ELECTRONIC CIRCUITS
8/16/2019 IS 3017
19/25
IS: 3017 1985
APPENDIX G
THERMAL CONTROLS AND OVERLOAD RELEASES
This Appendix of IS
:
302-1979* is not applicable.
APPENDIX H
MEASUREMENT OF CREEPAGE DISTANCES AND
CLEARANCES
This Appendix of IS : 302-1979* is applicable.
APPENDIX J
TEST FOR FIRE-RESISTING PROPERTIES
This Appendix of IS
:
3OL-1979* is applicable.
8/16/2019 IS 3017
20/25
IS : 3017 - 1985
APPENDIX AA
Clauses 103.1
and
18 )
METHOD OF DETERMINING OPERATING TEMPERATURE
AND DIFFERENTIAL OF THERMOSTATS
AA-l. GENERAL
AA-l.1 Test
Tank -
A test tank fitted with a horizontal pocket
on
one side into which the thermostat can be fitted to its full length shall
be used.
The pocket shall be of copper with an internal diameter o
8.5 mm and a wall thickness of 0.710 mm. The tank is filled with water
to a level 10 mm above the top level of the pocket.
A mercury-in-glass
thermometer is used to read the temperature of the water. Arrange-
ments are made for the uniform heating and cooling of the water-bath.
The ambient temperature of the room shall be 27 f 5°C.
AA-2. PROCEDURE
AA-2.1 Adjustable thermostats are tested with their controls set at 70°C
8/16/2019 IS 3017
21/25
IS:3017 - 1985
AA-2.2
The temperature of the water-bath shall be brought to 15°C
below the setting of the thermostat or its indicated temperature and
maintained at that level for one hour with the heating load connected
to the thermostat switched off by the control switch. At the end of one
hour, the temperature of the bath is uniformly raised at a rate not
exceeding 15°C per hour and the control switch is switched on, passing
the rated current through the contacts of the thermostat. The tempe-
rature of the water at the moment when the contacts open ( as indicated
by the test lamp ) is noted as the operating temperature ( cut-out
temperature ).
AA-2.3
The temperature of the water is then allowed to fall uniformly
at a rate not exceeding 15°C per hour and the temperature of the water
at the moment the contacts close ( as indicated by the test lamp ) is
noted as the cut-in temperature.
AA-2.4
The difference between the cut-out and cut-in temperature is the
differential for the thermostat.
8/16/2019 IS 3017
22/25
8/16/2019 IS 3017
23/25
AMENDMENT NO. 1 MARCH I390
TO
IS : 3017 - 1985 SPECIFICATION FOR THERMOSTATS
FOR USE WITH ELECTRIC WATER HEATERS
(
F irst Revision
[ Page 7 , clause 6.1(c)
]
-
Substitute the following for the existing matter
:
‘6.1 (c) According to temperature differential
l)Classl- Thermostats having temperature differential not exceeding 5 SC.
2) Class 2 - Thermostats having temperature differential not
exceeding
10 .*
(ETDC32)
Reprography nit.BIS,New Delh
8/16/2019 IS 3017
24/25
ARIENDMEN’I NO. 2 AUGUST 1991
TO
1s 3017 : 1985 SPECIFICATION
FOR THERMO-
STATS FOR USE WITH
ELECTRIC WATER
I 1
EATERS
( Page 13, Fig. 101 ) -- Substitue the following li,r the existing
figure:
-
I
SWITCH
HE AO_
I
SWITCH
HEAD
8/16/2019 IS 3017
25/25
AMENDMENT NO. 3 MAY 1992
TO
IS 3017 : 1985 SPECIFICATION FOR THERMOSTATS
FORUSE WITH ELECTRIC WATER HEATERS
First Revbion )
Substitute ‘IS 302-l(1979) Safety of household and similar electrical
appliances: Part 1 General requirements (
f i ft h revi si on )’ for ‘I S
302
:
1979
General and safety requirements for household and similar electrical appliances
f i f th evis ion’
wherever it appears in the standard.
(ETD32)