Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Disclosure to Promote the Right To Information
Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.
इंटरनेट मानक
“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”
“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru
“Step Out From the Old to the New”
“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan
“The Right to Information, The Right to Live”
“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
“Invent a New India Using Knowledge”
है”ह”ह
IS 1200-22 (1982): Method of measurement of building andcivil engineering works, Part 22: materials [CED 44:Methods of Measurement of Works of Civil Engineering]
i
IS : 1200 f Part XXII ) - 1982
Indian Standard
METHOD OF MEASUREMENT OF BUILDING AND CIVIL ENGINEERING WORKS
PART XXII MATERIALS
Civil Works Measurement Sectional Committee, BDC 44
Chairman Representing
l SERI P. N. GADI
Members
Institution of Surveyors, New Delhi
SHRI P. L. BHASIN ( Allsrnatc to Shri P. N. Gadi )
ADHIBHASI ARAYANTA ( PAE~EIKHAN )
DEPUTY DIRECTOR SHRI $G;w;z;z ) ( Alternate )
SH;~ $. V. SITARAM ( Alternate ) SHRI S. K. CEAKRABORTY DIRECTOR, IRI, ROOIZKEE
Public Works Department, Lucknow
Engineers India Ltd, New Delhi
Calcutta Port Trust, Calcutta Irrigation Department, Government of Uttar
Pradesh, Lucknow DIRECTOR ( RATES AND COSTS )
DEPUTY DIRECTOR ( RATES AND COSTS ) ( Alt8VIUte )
SHRI HARI RAO, P. S. SHRI N. M. DASTANE ( Alternate )
SRRI M. L. JA~N
Central Water Commission, New Delhi
Hindustan Construction Co Ltd, Bombay
National Industrial Development Corporation Ltd, New Delhi
JOINT DIRECTOR ( D ) SRRI A. K. LAL ( Alfernate )
SHRI H. K. KHOSLA SUPERINTENDING E N Q I N E E R
( CD0 ) ( Alternate ) SHRI S. K. LAIIA SHRI V. D. LONDHE
SHRI N. C. .DUQQAI, ( Alternate ) SIIRI K. K. MAD~OK SHRI DATTA S. MALIE
National Buildings Organization, New Delhi
Haryana Irrigation Department, Chandigarh
Institution of Engineers ( India ), Calcutta Concrete Association of India, Bombay
Builders’ Association of India, Bombay Indian Institute of Architects, Bombay
) PROP M. K. GODBOLE ( Allernate ( Conlinued on page 2 )
*Acted 8s cbalrman for the meeting in which the standard was fbnlized.
@ Copright 1982
INDIAN STANDARDS INSTITUTION
This publication is protected under the Indian Copyrighf Ad (XIV of 1957 ) and reproduction in whole or in part by any means except with written permission of tl:r
publisher shall be deemed to be an infringement of copyright under the said Acr. r
fS t 1200 (Part XXII ) - 1982
( Conlint& from pugs 1 )
Members Representing
SERI R.S.MU~THY SHRI H. D. MATANQE ( Alternate )
Gammon India Ltd, Bombay
SHRI B. S. MATEUIZ Ministry of Shipping and Wing )
Transport ( Roads
SRRI A. D. NARAIN ( Alternote ) SHRI C. B. PATEL M. N. Dastur & Co Ltd, Calcutta
SRRI B. C. PATEL ( Alternote ) S5an1 V. G. PATWARDHAN Ennineer-in-Chief’s Branch ( Ministry of Defence )
SHRI G. G. KARMARKAR ( Akvnate r S&u T. S. RATNAB~ Bureau of Public Enterprises, New Delhi Da R. B. SINQH Banaras Hindu University, Banaras
Hindustan Steel Works Construction Ltd, Calcutta Central Public Works Department, New Delhi
SHRI R. A. STJBRAMANIAM SUPERINTBNDINO SURVEYOR OB
WORKS ( Avx ) SURVEYOR OB Woarra I ( Avr )
( Alternate ) SHRI K. J. TARAPOREWALLA SH~I J. C. VERMA
SERI R. M. JOLLY ( Alternate ) SHRI G. RAYAN,
Director ( Civ Engg )
Bombay Port Trust, Bomhay Bhakra Management Board, Irrigation Wing,
Naogal Township
Director General, IS1 (Ex-ofi& Member )
SHRI K. M. MATHUR Deputy Director ( Civ Engg ), IS1
2
IS I 1200 ( Part XXII ) - 1982
Irrdian Standard
METHOD OF MEASUREMENT OF BUILDING AND CIVIL ENGINEERING WORKS
PART XXII MATERIALS
0. FOREWORD
0.1 This Indian Standard ( Part XXII ) was adopted by the Indian Standards Institution on 20 Aprii i982, after the draft finaiized by the Civil Works Measurement Sectional Committee had been approved by the Civil Engineering Division Council.
0.2 Measurement occupies a very important place in the planning and execution of any civil engineering work, from the time of first estimates to final completion and settlement of payments. Methods being followed for measurement are not uniform, and considerable differences exist between the practices followed by different construction agencies and also between various Central and State Government Departments. While it is recognized that each system of measurement has to be specifically related to administrative and financial organization with departments responsible for the wnrk 51 rlnifimtinn of th_e various rvetpinq at the= twhniral ls=w=l hn. . ...“., _ _-_...--.__-- ‘, .,.___.” _. .*.- .\-~...1.~1. ..,.-a -4”” been accepted as very desirable, specially as it permits a wider circle of operation for civil engineering contractors and eliminates ambiguities and misunderstandings arising out of inadequate understanding of various systems followed.
0.3 The practice for the method of measurement of supply of materials like sand, boulders, aggregates, etc varies considerably from one place to another with the result that a lot ofpractical difficulties arise in supply of such items. It has, therefore, been felt that methods of measurement of supply of such materials, as are generally taken from time to time for buildings and civil engineering works in substantial quantities, should be formulated. This part covers measurements of such materials.
0.4 In reporting the result of a measurement in accordance with this standard,‘if the final value observed or calculated is to be rounded off, it shall be done in accordance with IS : Z-1960*.
*Rules for rounding oli” numerical values ( revised ).
3
IS : 1200 ( Part XXII ) - 1982
1. SCOPE
1.1 This standard ( Part XXII ) covers the method of measurement materials normally used in buildings and civil engineering works.
2. GENERAL
of
2.1 Description of Item - Description of each item shall, unless other- wise stated, include, wherever necessary, conveyance and delivery, ,~__J,?__ .__,__J:__ _&.._I__ _A^ nanaung, unwaaulg, JLOI-~II~, C;CI;
2.2 Limits of Measurement - Dimensions shall be measured net in decimal system to the nearest 0 01. m, area to nearest 0.01 ms, volume to nearest 0’01 ms, weight to nearest 1 kg, unless otherwise stated ( see also relevant Indian Standard ).
2.3 Bills of Quantities -Bills of quantities shall fully describe materials.
3. METHOD OF MEASUREMENT OF MATERIALS
3.1 Various types of materials shall be measured as mentioned in Tabie 1.
TABLE 1 MEASUREMENT OF MATERIALS
NAME OB MATERIAL
Aggregates
Brick/stone.of 40 mm nominal size and above
Brick/stone aggregates of less than 40 mm size cinder, sand, m~c~ram, fly ash, pozzolana, stone, stone dust
Aluminium Flats
Aluminium Strip and Edging
Asbestns Cement Products
Barge boards
Ridge Guttera Roof lights, north light curves
Sheets Ventilators, eaves fillers, apron pieces,
louvers, cowls, ridge finials, septic tanks
How MEARUXED
In ma after making a deduction of 7.5 percent from stack measuremenfs and as per type
In Ins of gross stack measurements according to nominal size and type
In kg, stating size
In running metre stating size
Enumerated, stating size
In pairs, according to size and type
Enumerated, stating size, type and length Enumerated, stating size and type
Enumerated stating type, size and length Enumerated and described
( Continued )
4
IS t 1200 ( Part Xxi1 ) - 1982
TABLE 1 MEASUREMENT OF MATERL4LS - Cmtd
NAME OF MATERIAL
Bitumen Products
Bitumen felt
Bitumen hot sealing colhpound
Bitumen road tar
Joint filler ( sealing compound )
Boards
Plywood, etc
Bricks/Brick Tilt-s
Blocks (Building, Clay, Cement. Stone, etc)
Cement/Lime Pozzolana Mixture
Distemper
Doors/ Windows/ Ventilator Frames
Doors/ Windows/ Ventilators (Excluding Fittings and Finishes)
Fibre Glass Felt
Filler Fibrous/Non Ji6rous
Fittings for Doors and Windows
Galvanized Steel Barbed Wire
Galvanized Steel Sheets (Corrugated/Plain)
Glass Sheets ( Plain/Pin Head/Frosted/ Wired/ Splinter proof)
Class Strips
Jali Cement-Concrete/Clay
L.tad for Caulking
Lime
Marble Chips
Marble Dust
Marble Pieces
How MEA.~URED
In m8, stating type, grade and width
Ry weight, in kg, staring grade and type
In tonnes, stating type
In kg
In rns, statingtype and thickness
Enumerated, stating class and size
Enumerated stating size, type and grade if any
In kg, stating type.
In kg
In linear metres and described (outside dimensions measured )
In m8 and described
In ms stating thickness and grade
In m’ and described
Enumerated
In kg, s?ating type and size
In quintals or enumerated, sgating type and size
In ms, stating type, thickness and size
In running metres, stating thickness and width
In ma, stating thickness and type
In kg
In kg, stating class
In quintal, stating size and described
In kg
In kg, stating colour
( Continued )
___~ .._~
5
J:
IS : 1200 ( Part XXII ) - 1982
TABLE 1 MEASUREMENT OF MATERIALS - Contd
NAME OF MATERIAL
Marble Slab
Metal Beadhg
Paints, Emulsions and Thinners
Paint (Shy) and Pigment
Pipes and Accessories
Pipe fittinns
Pipes (except mild steel )
Precosl Unifsfur FIooring
Rope Manila
Rubbtr Rings for Pipes
SteCl
Mild steel sheets
Mild steel expanded metal
Wire fabric/chain fabric
Hoop iron/boits/rivets/barsjstructural sections/rails/mild steel pipes
stone Boundary stone/kilometre stone
Kerb stone
Fioor stone slabs
Soling stone, boulders, rubble
Sanitary Fiftings
Cisterns / clamps / cocks / ferrules,‘foot- rests / gratings / hydrants Itraps/bath tubsjurinais ivaivesjwash basins/‘WC pans/showers/towel rails/bidets
Tiles
Timber
Blocks/baulks
Ballies
How MEASURED
In mz, stating thickness and type
In running metres, stating type and size
In litres, stating type and class
In kg, stating type and class
Enumerated and described
In running metres and described
Enumerated and described
In kg and described
Enumerated and described
In tonnes, stating size and thickness
In mJ and described
In ma and described
In kg or tonnes and described
Enumerated, stating size and type
Enumerated, staling size
In rn2 and described
In rns, after making a deduction of i5 percent from gross stack measure- ments, stating nominal size and type
Enumerated and described
Enumerated, stating type and size
Enumerated, stating type and size
Enumerated, specifying diameter and described ( diameter shall be measured at !*5 m from the thick end )
( Confinued )
1s t 1200 ( Part SXrl ) - 1982
TABLE 1 MEASUREMENT OF MATERIALS - Contd
NAME 01~ MATERIALS
Barn boos
Scantlings/planks/battens
?ilts ( Other than sanitary )
Wall Tiles/False Ceiling Tilts/Roofing Tiles
Water Proojng Comjmnd
Water Proojing Paste/Ernzdsion/Liquid
Wire
Wire Rope
How MEASURED
Enumerated and described
In m3, stating size and type
In m2, stating size and type
Enumerated, statirlg type and size
In kg
In litres
In kg and described
In running metre and described
*