2
Insulation ballasted with washed paving slabs 0 Falls INVERTED FLAT ROOF Technical Advice 08456 71-71-74 www.cellecta.co.uk Cellecta R Drainage gully lining Insulation ballasted with paving slabs 1:60-1:80 Falls Cellecta HEXATHERM XMD Vertical up-stand insulation board Insulation ballasted with washed rounded gravel Suitable for roofs with and without falls Ir3 Ir4 Ir5 FASTRACK ARCHITECTURAL CAD DATABASES CAD FASTRACK ARCHITECTURAL BIM DATABASES BIM FASTRACK ARCHITECTURAL CAD DATABASES CAD FASTRACK ARCHITECTURAL BIM DATABASES BIM FASTRACK ARCHITECTURAL CAD DATABASES CAD FASTRACK ARCHITECTURAL BIM DATABASES BIM Waterproof membrane Structural roof deck (To structural engineer’s specification) Geotextile filter fleece Cellecta HEXATHERM XROOF 300L/XDRAiN Paving slab on supports Waterproof membrane Screed laid to falls Structural roof deck (To structural engineer’s specification) Cellecta HEXATEX (thermal improvement membrane) or Geotextile filter fleece Cellecta HEXATHERM XROOF 300L/XDRAiN Paving slab on supports Waterproof membrane Screed laid to falls Structural roof deck (To structural engineer’s specification) Cellecta HEXATEX (Thermal improvement membrane) or Geotextile filter fleece Cellecta HEXATHERM XMD (Vertical up-stand insulation) Thickness’ available: 6mm facing + 50 -160mm insulation Board dimensions: 1200mm x 2400mm Thermal resistance: 0.033-0.034W/m²K Washed rounded gravel ballast Cellecta HEXATHERM XROOF 300L/XDRAiN 21

INVERTED FLAT ROOF Cellecta - · PDF fileInsulation ballasted with washed paving slabs 0 Falls INVERTED FLAT ROOF Technical Advice 08456 71-71-74 Cellecta R Drainage gully lining

Embed Size (px)

Citation preview

Page 1: INVERTED FLAT ROOF Cellecta - · PDF fileInsulation ballasted with washed paving slabs 0 Falls INVERTED FLAT ROOF Technical Advice 08456 71-71-74 Cellecta R Drainage gully lining

Insulation ballasted with washed paving slabs0� Falls

INVERTED FLAT ROOF

Technical Advice 08456 71-71-74 www.cellecta.co.uk

CellectaR

Drainage gully liningInsulation ballasted with paving slabs

1:60-1:80 Falls

Cellecta HEXATHERM XMD Vertical up-stand insulation boardInsulation ballasted with washed rounded gravel

Suitable for roofs with and without falls

Ir3

Ir4

Ir5

FASTRACKA R C H I T E C T U R A L C A D D ATA B A S E S

CAD FASTRACKA R C H I T E C T U R A L B I M D ATA B A S E S

BIM

FASTRACKA R C H I T E C T U R A L C A D D ATA B A S E S

CAD FASTRACKA R C H I T E C T U R A L B I M D ATA B A S E S

BIM

FASTRACKA R C H I T E C T U R A L C A D D ATA B A S E S

CAD FASTRACKA R C H I T E C T U R A L B I M D ATA B A S E S

BIM

Waterproof membrane

Structural roof deck(To structural engineer’s specification)

Geotextile filter fleece

Cellecta HEXATHERM XROOF 300L/XDRAiN

Paving slab on supports

Waterproof membrane

Screed laid to falls

Structural roof deck(To structural engineer’s specification)

Cellecta HEXATEX (thermal improvement membrane)

or Geotextile filter fleece

Cellecta HEXATHERM XROOF 300L/XDRAiN

Paving slab on supports

Waterproof membrane

Screed laid to falls

Structural roof deck(To structural engineer’s specification)

Cellecta HEXATEX (Thermal improvement membrane)

or Geotextile filter fleece

Cellecta HEXATHERM XMD(Vertical up-stand insulation)Thickness’ available: 6mm facing + 50 -160mm insulationBoard dimensions: 1200mm x 2400mmThermal resistance: 0.033-0.034W/m²K

Washed rounded gravel ballast

Cellecta HEXATHERM XROOF 300L/XDRAiN

21

Page 2: INVERTED FLAT ROOF Cellecta - · PDF fileInsulation ballasted with washed paving slabs 0 Falls INVERTED FLAT ROOF Technical Advice 08456 71-71-74 Cellecta R Drainage gully lining

Closed cell structure

High compressive strength

Very low water absorption

Excellent life-long thermal performance

ROOF L300

XROOF 300L extruded polystyrene thermal insula�on boards are designed specifically for inverted roof applica�ons where a high resistance to compression and very low water absorp�on is essen�al.

Thermal Conduc�vity BS EN 12667 (W/mK)

Temperature range

Compressive strengthBS EN 826

Board size (mm)

Thickness’ (mm)(other sizes manufactured to order)

Long term water absorp�onby immersion BS EN 12087

Compressive strengthBS EN 1606

Edge profile

300kPa

125kPa

0.7%

-50/+75�C

600x 1250

50 6080

100 120140 160

Shiplap

XROOF L300

75

0.0330.034

<80mm>81mm

Product Benefits

Physical Properties

Product Information

*Not applicable under Q-mark Certification

Technical Advice 08456 71-71-74 www.cellecta.co.uk

INVERTED FLAT ROOF CellectaR

High compressive strength

Very low water absorption

Excellent life-long thermal performance

DRAiN

XDRAiN extruded polystyrene inverted roo�oards have with a unique pa�en of drainage channels on their underside specifically which speeds up the shedding of rainwater, elimina�on the need for a separa�on drainage mat, making them ideal for green roofs.

Thermal Conduc�vity BS EN 12667 (W/mK)

Temperature range

Compressive strengthBS EN 826

Board size (mm)

Thickness’ (mm)(other sizes manufactured to order)

Long term water absorp�onby immersion BS EN 12087

Compressive strengthBS EN 1606

<80mm>81mm

Edge profile

Integral drainage channels

300kPa

125kPa

0.7%

-50/+75�C

600x 1250

50 6080

100 120140 160

Shiplap

75

XDRAiN

0.0330.034

Product Benefits

Physical Properties

Product Information