2
AP MALDI MS spectra of peptide mixture of Angiotensin II (MW 1046 Da) and P14R (MW 1534 Da): 10 fmol and 1 fmol (insert) loaded 0 20 40 60 80 100 600 800 1000 1200 1400 1600 1800 Relative Intensity (%) m/z 1046.7 1534.1 0 20 40 60 80 100 600 800 1000 1200 1400 1600 1800 Relative Intensity (%) m/z 1046.6 1534.0 1 fmol 10 fmol Interfaced with AP/MALDI Ion Source for Biological Applications Features: Atmospheric pressure interface (API) MS and MS/MS modes of operation Mass range: 30-2,500 Da Mass accuracy: 0.3 Da Weight: 75 lbs Dimension: 12” x 17”x 20” Power: 100-300 W MT Explorer 50 in combination with AP/MALDI A compact tandem mass analyzer with performance of a desktop instru- ment - ideal for field and lab hood use Limit of Detection 6992 Columbia Gateway Dr, Columbia, MD 21046 USA Tel: 443-539-1758 Fax: 443-539-1759 Web: www.apmaldi.com E-mail: [email protected]

Interfaced with AP/MALDI Ion Sourceapmaldi.com/main/wp-content/uploads/bsk-pdf-manager/MTExp50... · AP MALDI MS spectra of peptide mixture of Angiotensin II (MW 1046 Da) and P14R

Embed Size (px)

Citation preview

Page 1: Interfaced with AP/MALDI Ion Sourceapmaldi.com/main/wp-content/uploads/bsk-pdf-manager/MTExp50... · AP MALDI MS spectra of peptide mixture of Angiotensin II (MW 1046 Da) and P14R

AP MALDI MS spectra of peptide mixture of Angiotensin II (MW 1046 Da) and P14R (MW 1534 Da): 10 fmol and 1 fmol (insert) loaded

0

20

40

60

80

100

600 800 1000 1200 1400 1600 1800

Relat

ive In

tens

ity (%

)

m/z

1046.7

1534.1

0

20

40

60

80

100

600 800 1000 1200 1400 1600 1800

Relati

ve Inte

nsity (

%)

m/z

1046.6

1534.0

1 fmol 10 fmol

Interfaced with AP/MALDI Ion Sourcefor Biological Applications

Features:Atmospheric pressure interface (API) MS and MS/MS modes of operationMass range: 30-2,500 DaMass accuracy: 0.3 DaWeight: 75 lbsDimension: 12” x 17”x 20”Power: 100-300 W

MT Explorer 50 in combination with AP/MALDI

A compact tandem mass analyzer with performance of a desktop instru-ment - ideal for �eld and lab hood use

Limit of Detection

6992 Columbia Gateway Dr, Columbia, MD 21046 USATel: 443-539-1758 Fax: 443-539-1759 Web: www.apmaldi.com E-mail: [email protected]

Page 2: Interfaced with AP/MALDI Ion Sourceapmaldi.com/main/wp-content/uploads/bsk-pdf-manager/MTExp50... · AP MALDI MS spectra of peptide mixture of Angiotensin II (MW 1046 Da) and P14R

0

20

40

60

80

100

600 800 1000 1200 1400 1600

Relati

ve Int

ensity

(%)

m/z

y5

562.9

y6

660.0

y7

y8

854.1

y9

y10

1048.3

y11

y12

1241.7

y13

y14

1437.4

757.0

951.2

1145.2

1339.3

0

20

40

60

80

100

600 800 1000 1200 1400 1600

Rel

ativ

e In

tens

ity (%

)

m/z

y5

562.9

y7 y8

854.1

y9

y10

1048.3

y11

y13

756.9

951.2

1145.3

1339.3

1533.7

AP MALDI MS/MS spectra of P14R peptide ions: 10 fmol and 1 fmol (insert) loaded

AP MALDI MS spectrum of Bacillus Globigii spores after chemical processing and digestion by trypsin (BG spores biomarker peptide are indicated)

AP MALDI MS/MS spectrum of BG peptide ion with m/z value of 1585 in the spectrum above

MS/MS Capability

Identi�cation of Bacillus Globigii Spores

0

20

40

60

80

100

1000 1100 1200 1300 1400 1500 1600 1700 1800 1900

Relati

ve Inte

nsity (

%)

m/z

1927.6*

*

*

1497.0

1584.9

1740.9

0

20

40

60

80

100

600 800 1000 1200 1400 1600

Relati

ve Int

ensity

(%)

m/z

1019.31274.3

1291.2

1372.3

1402.5

1419.5

1567.61586.7

MS

MS/MS

1 fmol 10 fmol

6992 Columbia Gateway Dr, Columbia, MD 21046 USATel: 443-539-1758 Fax: 443-539-1759 Web: www.apmaldi.com E-mail: [email protected]