Installation Instructions

5" Slide in Shelf with VESA Plate

w w w . a m i c o . c o m

1 Amico Accessories Inc.

Important, Please Read Carefully

Thank you for your purchase with Amico.

This unit is designed for long lasting performance, providing the end user complies with assembly and maintenance procedures. This Instruction Manual is your guide to ensure that you get the best performance out of the equipment. Amico Accessories is not responsible for any damage as a result of (but not limited to) abuse and other problems that may be a direct or indirect result of failure to comply with the instructions provided in this manual.

Please note these key words and symbols:

WARNING Steps where extra care should be taken to prevent injuries and damage

NOTE Steps that point out helpful information

RESPONSIBILITY OF MEDICAL FACILITIES

Preventive maintenance checks must be performed regularly to maintain the quality and performance of this product. Any parts that may be broken, missing, worn, distorted, or contaminated in any way should not be used and all affected parts should be replaced immediately. Should the necessity of any repair be suspected; please contact your local distributor.

Preface

www.amico.com 2

Table of Contents

Section 1: Product SpecificationsFeatures 3Specifications 3

Section 2: Installation PreparationInstallation Tools 4Installation Reference 4Mounting Options 4Parts Legend 5

Section 3: Mounting to PlatformMounting on MRS 6Mounting on VRS and Ohmeda Rail 7Mounting on ARS 8Mounting on PLV/PLH 9Mounting on GTA/Hill-Rom 10Mounting on DIN Rail 11Mounting on FRS (Fairfield) and LRS 11Mounting on Pole Clamp (1.25", 1.5" and 2" Diameter) 12

Section 4: Mounting to DeviceMounting to Device 13-14

Section 5: Adjustments 15

Section 6: Maintenance and TroubleshootingTroubleshooting Guide 16Maintenance 16

Cleaning 17

Warranty 18

3 Amico Accessories Inc.

Section 1: Product Specifications

Features

1. Easy to clean

2. Secure locking plunger for quick release

3. 75/100 VESA mounting options with easy installation slots

4. Compatible with a variety of rail types

Specifications

1. Maximum load of 20 lbs (9.1 kg)

2. 5.00" L x 5.74" H

MODEL MAXIMUM DEPTHBack of adapter to front of plate (back of monitor) distance.

V = 3.16" (8.03 cm)

D = 3.25" (8.23 cm)

F = 3.25" (8.23 cm)

*M = 1.28" (3.25 cm)

A = 2.92" (7.42 cm)

E25 = 2.15" (5.46 cm)

G = 3.35" (8.51 cm)

S = 3.75" (9.53 cm)

PLH = 3.18" (8.07 cm)

PLV = 3.19" (8.10 cm)

R200 = 3.40" (8.64 cm)

5.000

5.0

00

FOR USE WITH: PM5-V

3.1

60

5.000

5.0

00

FOR USE WITH PM5-A

2.9

19

2.7

57

5.0

00

5.000 FOR USE WITH PM5-D

3.2

48

5.000

5.0

00

FOR USE WITH PM5-E25

1.9

00

1.767

5.000

5.0

00

FOR USE WITH PM5-F

1.5

31

5.000

5.0

00

FOR USE WITH PM5-G

3.3

50

5.7

40

5.000 FOR USE WITH PM5-M

1.2

80

1.400

5.000

5.0

00

3.7

50

FOR USE WITH: PM5-_(__) Project #: 0438

FOR USE WITH PM5-S

UNLESS SPECIFIED ALL DIMENSIONS IN INCHESBREAK ALL EDGES .005 - .010ANGLE TOLERANCES 1FRACTIONAL TOLERANCES 1/32DECIMAL TOLERANCES: .XX .03 .XXX .005 .XXXX .0005

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 2

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

SK FEB/10/2015EC FEB/10/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

CAD BLOCK FOR PM5-_(__)

PM5-(__)CAD

20150210-S3411

PROJECTION

www.amico.com

1.4" (3.55 cm)

PM5-M*

1.28

" (3.

25 c

m)

5.000

5.0

00

FOR USE WITH: PM5-V

3.1

60

5.000

5.0

00

FOR USE WITH PM5-A

2.9

19

2.7

57

5.0

00

5.000 FOR USE WITH PM5-D

3.2

48

5.000

5.0

00

FOR USE WITH PM5-E25

1.9

00

1.767

5.000

5.0

00

FOR USE WITH PM5-F

1.5

31

5.000

5.0

00

FOR USE WITH PM5-G

3.3

50

5.7

40

5.000 FOR USE WITH PM5-M

1.2

80

1.400

5.000

5.0

00

3.7

50

FOR USE WITH: PM5-_(__) Project #: 0438

FOR USE WITH PM5-S

UNLESS SPECIFIED ALL DIMENSIONS IN INCHESBREAK ALL EDGES .005 - .010ANGLE TOLERANCES 1FRACTIONAL TOLERANCES 1/32DECIMAL TOLERANCES: .XX .03 .XXX .005 .XXXX .0005

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 2

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

SK FEB/10/2015EC FEB/10/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

CAD BLOCK FOR PM5-_(__)

PM5-(__)CAD

20150210-S3411

PROJECTION

www.amico.com

5" (12.7 cm)

5.74

" (14

.58

cm)

www.amico.com 4

Installation Tools

Installation Reference

A: Tools

1/8" hex key 7/32" hex key (FTA only)

4 x PLASTIC SCREWS[H-PHSCS-1420-12]

SHELF[PM5-X] MOUNTING ADAPTER

PLUNGER PIN[X-MON-PLUNPIN] VESA PLATE

[MON-VESA-ADA](Hardware not shown)

Section 2: Installation Preparation

Amico Accessories includes all the adapters required for the above rail systems

Mounting Options

V = Amico Vertical Rail Mount (compatible with Amico and Modular)

D = Dovetail Rail Mount (compatible with Ohmeda Rail)

F = Fairfield Rail Mount (push button optional)

*M = Monitor Rail Mount

A = Amico Horizontal Rail Mount (compatible with Amico and Modular)

E25 = DIN 25mm (1") Rail Mount (30mm [1.2"], 35mm [1.4"] optional)

G = Hill-Rom Vertical Rail Mount

S = HSI Vertical Rail Mount

PLH = Horizontal Pole Clamp (adjustable)

PLV = Vertical Pole Clamp (adjustable)

R200 = 2" Diameter Pole Clamp

5 Amico Accessories Inc.

Section 2: Installation Preparation

Manufacturer Part Number Part DescriptionH-PHSCS-1420-12 PLASTIC SCREWS

MON-PM5-SHELF SHELF

X-MON-PLUNPIN PLUNGER PIN

MON-VESA-ADA VESA PLATE

H-SSCP-1420-05 SET SCREWS

VTA-X-LOCKNOB VERTICAL TRACK ADAPTER LOCK KNOB

V-ADAPTER (VTA-8-32) VERTICAL TRACK ADAPTER

X-HBLOCK-ARM LEVER ARM

X-PC1-CLMP-CLP CLAMP

X-PLV-832-BDY CLAMP BODY

H-PC1-CLMP-HDL KNOB

H-NUT-M8-NYL NUT

X-MON-CLAMP-A HORIZONTAL TRACK ADAPTER

H-HSSS-71620-38 ALLOX HEX SOCK SET SCREWS

W-X-BALL-375-NY NYLON WHITE BALL BEARINGS

H-HR-CONV-PIN-2 GTA/HILL-ROM TRACK ADAPTER PIN(S)

ETA ADAPTER (ETA-8-32) DIN TRACK ADAPTER

X-GTA-KNOB GTA/HILL-ROM ADAPTER KNOB

X-PC-2-1-8-32 FRONT HALF CLAMP

X-PC-2-2-8-32 BACK HALF CLAMP

H-PHSCS-1420-10 SOCKET HEAD CAP SCREWS

Parts Legend

NOTE: Please note part descriptions provided below.

www.amico.com 6

Mounting on MRS

1. Lift the SHELF and guide the MOUNTING ADAPTER into the top of the MRS rail as shown. Ensure 2 x SET SCREWS are loosened to allow height adjustment.

2. Once the SHELF is in the desired position on the MRS rail, tighten 2 x SET SCREWS to the tightest possible position on the MOUNTING ADAPTER using a 1/8" hex key.

MRS RAIL

MOUNTINGADAPTER

[MON-ADA-LNG]

Figure 2

2 x BLACKSET SCREWS

[H-SSCP-1420-05]

MOUNTINGADAPTER

MRS RAIL

TOP MONITORBRACKET STOPPER[W-X-MON-STOP-T]

BOTTOM MONITORBRACKET STOPPER[E-MON-STOP-B]

CUSTOMER DRAWINGFOR USE WITH CPUMNT_-_MOUNTING TO THE MRS

WARNING: DO NOT mount the CPU Mount anywhere near or above a Patient’s head.

WARNING: To prevent the Mounting Adapter from sliding down the MRS, ensure the four set screws are fastened to the tightest possible position, seriousinjuries could result if the set screws are not properly fastened. (Figure 1)

WARNING: Ensure rail is stable and properly installed before mounting CPU Mount.

NOTE: The MONITOR BRACKET STOPPERS (TOP & BOTTOM) are there to prevent the MOUNTING ADAPTER from sliding out of the MRS RAIL. The MOUNTING ADAPTER must be taken out from the top of the MRS RAIL with the TOP MONITOR BRACKET STOPPER pressed back into the MRS RAIL (Figure 2)

NOTE: Figure 2 shows the MOUNTING ADAPTER without the CPU MOUNT. This is only for clarity.

1. Lift up the CPU MOUNT and guide the MOUNTING ADAPTER into the top of the MRS RAIL as shown (Figure 1).

2. Once it is in the desired position on the MRS RAIL, tighten the 2 x BLACK SET SCREWS to the tightest possible position on the MOUNTING ADAPTERusing a 1/8’’ HEX key.

Figure 1

NOTE: LENGTH OF MRS SHOWN IS FOR REPRESENTATIONAL USE ONLY

PROJECT 0497

Manufacturer Part Number Part Description

MON-ADA-LNG Mounting adapter

W-X-MON-STOP-T Top monitor bracket stopper

E-MON-STOP-B Bottom monitor bracket stopper

H-SSCP-1420-05 Black set screw

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 10

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

CPUMNT_-_

20140904-S3043C

PROJECTION

SEPT/5/2014SEPT/5/2014

ECSK

CUSTOMER GUIDE FOR CPUMNT INSTALLATION

MONITOR BRACKET STOPPER - TOP[W-X-MON-STOP-T]

Press back into MRS rail

NOTE: Length of MRS shown is for representational use only

MRS RAIL

MOUNTING ADAPTER[MON-ADA-LNG]

2 x BLACK SET SCREW CUP[H-SSCP-1420-05]

MONITOR BRACKET STOPPER - BOTTOM[E-MON-STOP-B]

Section 3: Mounting to Platform

7 Amico Accessories Inc.

Mounting on VRS and Ohmeda Rail

NOTE: When the VERTICAL ADAPTER LOCK KNOB is turned clockwise, it causes the lock of the adapter to slide inward, locking the adapter onto the rail. When it is turned counter-clockwise, it causes the adapter to slide outward, unlocking the adapter.

INSTRUCTIONS

1. Angle the MOUNTING ADAPTER from the left of the VRS rail and rotate the adapters into the groove of the rail.

2. Tighten the VERTICAL ADAPTER LOCK KNOB when SHELF is at the desired height. Ensure it is completely tightened.

Section 3: Mounting to Platform

RAIL

ADAPTER (Provided in hardware kit)

KNOB (provided in hardware kit)

www.amico.com 8

Mounting on ARS

WARNING: AFTER THE MOUNTING ADAPTERS ARE INSTALLED, ENSURE THAT THE LEVERS ON THE MOUNTING ADAPTERS ARE PRESSED IN AS FAR AS POSSIBLE AND THE ADAPTERS ARE PLACED CORRECTLY INSIDE THE RAIL BEFORE MOUNTING DEVICES.

INSTRUCTIONS

1. Install MOUNTING ADAPTER onto rail by angling the upper lip into the inside lip of the ARS, pull the LEVER ARM back against the HORIZONTAL TRACK ADAPTER and push into the rail. Once secure, release the LEVER ARM.

Section 3: Mounting to Platform

ARS-__/ AMICO HEADWALLS / HORIZONTAL RAILS ON MODULAR HEADWALLS

(Tolerance may vary for modular rails)

LEVER ARM[X-HBLOCK-ARM]

PULL DIRECTION

ATA-__-__

ATA-__-__

(Step 1) (Step 2)

9 Amico Accessories Inc.

FRONT VIEW

ISOMETRIC VIEW

X-PLV-832-BDY

H-PC1-CLMP-HDL

VERTICAL POST

GROOVES ON X-PC1-CLMP-CLP

CUSTOMER DRAWINGFOR USE WITH: PLV-8-32PROJECT 443

NOTE: BEFORE MOUNTING THE PLV-8-32 ONTO THE MOUNTING PLATFORM, FIRST ENSURE THE HANDLE (H-PC1-CLMP-HDL) IS LOOSE (I.E. THE HANDLE IS IN ITS OUTER MOST POSITION. IF HANDLE IS NOT IN ITS OUTER MOST POSITION THEN ROTATE THE HANDLE COUNTER CLOCKWISE IN ORDER TO MAKE IT SO) NEXT, FOLLOW THE STEPS PROVIDED FOR MOUNTING THE PLV-8-32 ONTO THE MOUNTING PLATFORM.

*WARNING* - DO NOT ATTEMPT TO MOUNT/REMOVE THE PLV-8-32 WHEN LOADED WITH ANY DEVICE.*WARNING* - DO NOT MOUNT THE PLV-8-32 ABOVE THE PATIENTS HEAD.*WARNING* - ENSURE POST IS STABLE AND PROPERLY INSTALLED BEFORE MOUNTING THE PLV-8-32

1. ALIGN THE CLAMP (X-PLV-832-BDY) PERPENDICULAR TO THE AXIS OF THE POST AND TIGHTEN THE HANDLE (H-PC1-CLMP-HDL) BY TWISTING IT CLOCKWISE.

NOTE: THE PLV-8-32 IS ONLY COMPATIBLE WITH 0.75"-1.5" OUTER DIAMETER POST.

NOTE: MAKE SURE THE POST SITS BETWEEN THE GROOVES ON THE BOTTOM CLAMP(X-PC1-CLMP-CLP)AND ON THE BODY(X-PLV-832-BDY)

NOTE: FOR CLARITY, FIGURES BELOW SHOW MOUNTING OF PLV-8-32 WITHOUT ANY DEVICE ATTACHED

MOUNTING TO THE MOUNTING PLATFORM: POST

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 3

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

MOUNTING PLV-8-32 ONTO POST

SK DEC/23/2014EC DEC/23/2014

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PLV-8-32

20141223-S3342

PROJECTION

www.amico.com

FRONT VIEW

ISOMETRIC VIEW

H-LNUT-M8-NYL

X-PLV-832-BDY

CUSTOMER DRAWINGFOR USE WITH: PLV-8-32PROJECT 4432. TIGHTEN THE NUT (H-LNUT-M8-NYL) BY ROTATING IT CLOCKWISE ONTO THE CLAMP BODY (X-PLV-832-BDY)

*WARNING* :ENSURE THE X-PC1-CLMP-CLP IS COMPLETELY TIGHTENED AND SECURED ONTOTHE MOUNTING PLATFORM BEFORE TIGHTENING THE NUT AND LOCKING THE PLV-8-32 ONTO THE MOUNTING PLATFORM.

NOTE: TO UNINSTALL, REMOVE EQUIPMENT THENROTATE THE NUT (H-LNUT-M8-NYL)COUNTERCLOCKWISE AND THEN,ROTATE THE HANDLE (H-PC1-CLMP-HDL)COUNTERCLOCKWISE UNTIL THE PLV-8-32 CANBE REMOVED.

NOTE: FOR CLARITY, FIGURES BELOW SHOW MOUNTING OF PLV-8-32 WITHOUT ANY DEVICE ATTACHED

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 3

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

MOUNTING PLV-8-32 ONTO POST

SK DEC/23/2014EC DEC/23/2014

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PLV-8-32

20141223-S3342

PROJECTION

www.amico.com

Mounting on PLV/PLH

NOTE: The figures below show mounting without any device attached.

NOTE: The PLV-8-32 is only compatible with 0.75"-1.5" diameter posts.

NOTE: Ensure the post sits between grooves on bottom CLAMP CLIP and body of CLAMP.

INSTRUCTIONS

1. Align CLAMP BODY perpendicular to the axis of the post and tighten the KNOB by turning clockwise.

NOTE: To uninstall, remove equipment then rotate NUT counterclockwise, then rotate KNOB counterclockwise until CLAMP BODY can be removed.

2. Tighten NUT by rotating KNOB clockwise onto CLAMP BODY.

Grooves onCLAMP

[X-PC1-CLMP-CLP]

KNOB[H-PC1-CLMP-HDL]

NUT[H-NUT-M8-NYL]

ISOMETRIC VIEW

ISOMETRIC VIEWFRONT VIEW

CLAMP BODY[X-PLV-832-BDY]

(Hardware not shown)

CLAMP BODY[X-PLV-832-BDY]

(Hardware not shown)

FRONT VIEW

ISOMETRIC VIEW

X-PLV-832-BDY

H-PC1-CLMP-HDL

VERTICAL POST

GROOVES ON X-PC1-CLMP-CLP

CUSTOMER DRAWINGFOR USE WITH: PLV-8-32PROJECT 443

NOTE: BEFORE MOUNTING THE PLV-8-32 ONTO THE MOUNTING PLATFORM, FIRST ENSURE THE HANDLE (H-PC1-CLMP-HDL) IS LOOSE (I.E. THE HANDLE IS IN ITS OUTER MOST POSITION. IF HANDLE IS NOT IN ITS OUTER MOST POSITION THEN ROTATE THE HANDLE COUNTER CLOCKWISE IN ORDER TO MAKE IT SO) NEXT, FOLLOW THE STEPS PROVIDED FOR MOUNTING THE PLV-8-32 ONTO THE MOUNTING PLATFORM.

*WARNING* - DO NOT ATTEMPT TO MOUNT/REMOVE THE PLV-8-32 WHEN LOADED WITH ANY DEVICE.*WARNING* - DO NOT MOUNT THE PLV-8-32 ABOVE THE PATIENTS HEAD.*WARNING* - ENSURE POST IS STABLE AND PROPERLY INSTALLED BEFORE MOUNTING THE PLV-8-32

1. ALIGN THE CLAMP (X-PLV-832-BDY) PERPENDICULAR TO THE AXIS OF THE POST AND TIGHTEN THE HANDLE (H-PC1-CLMP-HDL) BY TWISTING IT CLOCKWISE.

NOTE: THE PLV-8-32 IS ONLY COMPATIBLE WITH 0.75"-1.5" OUTER DIAMETER POST.

NOTE: MAKE SURE THE POST SITS BETWEEN THE GROOVES ON THE BOTTOM CLAMP(X-PC1-CLMP-CLP)AND ON THE BODY(X-PLV-832-BDY)

NOTE: FOR CLARITY, FIGURES BELOW SHOW MOUNTING OF PLV-8-32 WITHOUT ANY DEVICE ATTACHED

MOUNTING TO THE MOUNTING PLATFORM: POST

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 3

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

MOUNTING PLV-8-32 ONTO POST

SK DEC/23/2014EC DEC/23/2014

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PLV-8-32

20141223-S3342

PROJECTION

www.amico.com

FRONT VIEW

ISOMETRIC VIEW

H-LNUT-M8-NYL

X-PLV-832-BDY

CUSTOMER DRAWINGFOR USE WITH: PLV-8-32PROJECT 4432. TIGHTEN THE NUT (H-LNUT-M8-NYL) BY ROTATING IT CLOCKWISE ONTO THE CLAMP BODY (X-PLV-832-BDY)

*WARNING* :ENSURE THE X-PC1-CLMP-CLP IS COMPLETELY TIGHTENED AND SECURED ONTOTHE MOUNTING PLATFORM BEFORE TIGHTENING THE NUT AND LOCKING THE PLV-8-32 ONTO THE MOUNTING PLATFORM.

NOTE: TO UNINSTALL, REMOVE EQUIPMENT THENROTATE THE NUT (H-LNUT-M8-NYL)COUNTERCLOCKWISE AND THEN,ROTATE THE HANDLE (H-PC1-CLMP-HDL)COUNTERCLOCKWISE UNTIL THE PLV-8-32 CANBE REMOVED.

NOTE: FOR CLARITY, FIGURES BELOW SHOW MOUNTING OF PLV-8-32 WITHOUT ANY DEVICE ATTACHED

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 3

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

MOUNTING PLV-8-32 ONTO POST

SK DEC/23/2014EC DEC/23/2014

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PLV-8-32

20141223-S3342

PROJECTION

www.amico.com

FRONT VIEW

Section 3: Mounting to Platform

www.amico.com 10

Mounting on GTA/Hill-Rom

INSTRUCTIONS

1. Loosen GTA/HILL-ROM ADAPTER KNOB until GTA/HILL-ROM TRACK ADAPTER PIN is long enough to fit into rail.

2. Turn MOUNTING ADAPTER 90 degrees to rail and insert GTA/HILL-ROM TRACK ADAPTER PIN into rail slowly. Turn back 90 degrees until MOUNTING ADAPTER is parallel to rail as shown in Figure 2.

3. Adjust height of MOUNTING ADAPTER and secure GTA/HILL-ROM ADAPTER KNOB by tightening as shown in Figure 3.

Section 3: Mounting to Platform

(Figure 1) (Figure 2)

(Figure 3)

GTA/HILL-ROM ADAPTER KNOB[X-GTA-KNOB]

GTA/HILL-ROM ADAPTER

GTA/HILL-ROM TRACK ADAPTER PIN(S)

[H-HR-CONV-PIN-2] RAIL

11 Amico Accessories Inc.

Mounting on DIN Rail

INSTRUCTIONS

1. Fully press the DIN TRACK ADAPTER button and angle the adapter towards the rail (as shown by the arrow) and ensure the groove on the adapter sits on the groove of the DIN rail.

2. Adjust placement of DIN TRACK ADAPTER and release button to secure.

Section 3: Mounting to Platform

Mounting on FRS (Fairfield) and LRS

NOTE: The Fairfield rail and the LRS rail use the same adapter. The installation procedure is the same for both adapter. Only the Fairfield configuration is shown below.

INSTRUCTIONS

1. Unscrew 2 x ALLOY HEX SOCK SET SCREWS on adapter. Do not unscrew all the way, only until the top of the bearings are flush with the adapter surface. Push the adapter towards the rail (as shown by the arrow) and ensure the groove on the adapter sits on the groove of the rail.

2. Completely tighten the bearings and ensure the bearings sit on the bottom groove of the rail.

10 mm x 25 mmEUROPEAN DIN RAIL

ETA-BUTTON

(Figure 1)

(Figure 1)

(Figure 2)

(Figure 2)

DIN TRACK ADAPTER[ETA ADAPTER (ETA-8-32)]

www.amico.com 12

Mounting on Pole Clamp (1.25", 1.5" and 2" Diameter)

INSTRUCTIONS

1. Align FRONT HALF CLAMP perpendicular to axis of the post at desired height as shown.

2. Align the holes of BACK HALF CLAMP to FRONT HALF CLAMP with pole sandwiched between.

3. Insert 2 SOCKET HEAD CAP SCREWS through BACK HALF CLAMP and tighten into FRONT HALF CLAMP evenly.

FRONT HALF CLAMP[X-PC-2-1-8-32]

BACK HALF CLAMP[X-PC-2-2-8-32]

2 x SOCKET HEAD CAP SCREWS

[H-HSCS-1420-10]

2" DIAMETER POST(Not provided)

Section 3: Mounting to Platform

13 Amico Accessories Inc.

Mounting to Device

INSTRUCTIONS

1. Place MONITOR face down on a padded surface and attach VESA PLATE to monitor using 4 x SCREWS (Figure 1).

2. Pull PLUNGER PIN back and rotate 90 degrees in order to disengage the plunger as shown in Figure 2 (only the MRS configuration is shown below). At this stage, the PLUNGER pin will not protrude through the front hole of the SHELF (Figure 3). Please note this when mounting device. Loosen 4 x SOCKET CAP SCREWS to be flush with the surface of the SHELF.

MONITOR(Not provided by Amico)

4 x M4 SCREWS

VESA PLATE[MON-VESA-ADA]

MONITOR (NOT PROVIDED BY AMICO)

X-MON-VESA-ADA

4 X M4 SCREWS

FIGURE 1

X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE1. PLACE MONITOR, FACE DOWN, ON A PADDED SURFACE AND ATTACH X-MON-VESA-ADA TO THE MONITOR USING THE 4 X M4 SCREWS (FIGURE 1).

2. SLIDE X-MON-VESA-ADA INTO X-PM5-SHELF (FIGURE 2). NOTE THAT THE X-PM5-SHELF SHOULD BE SECURELY ATTACHED TO THE MOUNTING PLATFORM BY THIS STAGE AND THE X-MON-PLUNPIN SHOULD BE DISENGAGED. TO DISENGAGE X-MON-PLUNPIN, SEE INSTRUCTIONS IN "MOUNTING TO THE PLATFORM" SECTION

FIGURE 2

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

MONITOR (NOT PROVIDED BY AMICO)

X-MON-VESA-ADA

4 X M4 SCREWS

FIGURE 1

X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE1. PLACE MONITOR, FACE DOWN, ON A PADDED SURFACE AND ATTACH X-MON-VESA-ADA TO THE MONITOR USING THE 4 X M4 SCREWS (FIGURE 1).

2. SLIDE X-MON-VESA-ADA INTO X-PM5-SHELF (FIGURE 2). NOTE THAT THE X-PM5-SHELF SHOULD BE SECURELY ATTACHED TO THE MOUNTING PLATFORM BY THIS STAGE AND THE X-MON-PLUNPIN SHOULD BE DISENGAGED. TO DISENGAGE X-MON-PLUNPIN, SEE INSTRUCTIONS IN "MOUNTING TO THE PLATFORM" SECTION

FIGURE 2

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

(Figure 1)

Section 4: Mounting to Device

(Figure 2)

X-MON-PLUNPIN

X-PM5-SHELF

PULL BACK AND ROTATE 90 DEGREES

FIGURE 1

X-MON-PLUNPIN DOES NOT PROTRUDE THROUGH THE FRONT HOLE IN X-PM5-SHELF

X-PM5-SHELF

4 X H-PHSCS-1420-12

4 X H-PHSCS-1420-12 FLUSH WITH THE SURFACE OF X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)PROJECT: 0438

NOTE: ENSURE THE MOUNTING RAIL/POST IS STABLE AND MOUNTED AS PER MANUFACTURERS INSTRUCTIONS

NOTE: ENSURE THE RAIL/POST IS NOT MOUNTED ABOVE A PATIENT

NOTE: THE LOAD RATING FOR THE PM5-_ IS 15 LBS, EXCEEDING THIS LIMIT CAN CAUSE FAILURE AND RESULT IN A SERIOUS INJURY

VRS: REFER TO THE USER MANUAL FOR VTA-8-32

ARS: REFER TO THE USER MANUAL FOR ATA-8-32

PLV/PLH: REFER TO THE USER MANUAL FOR PLV-8-32

GTA: REFER TO THE USER MANUAL FOR GTA-8-32

OHMEDA/DOVETAIL: REFER TO THE USER MANUAL FOR OHM-8-32

E25: REFER TO THE USER MANUAL FOR ETA-8-32

HSI: REFER TO THE USER MANUAL FOR STA-8-32

FRS: REFER TO THE USER MANUAL FOR FTA-8-32

MRS: REFER TO THE USER MANUAL FOR CPUMNTA-M

R200: REFER TO THE USER MANUAL FOR PC-2-8-32

MOUNTING ONTO PLATFORM

ONCE THE PRODUCT HAS BEEN MOUNTED ONTO THE PLATFORM COMPLETE THE STEP BELOW.

1. PULL X-MON-PLUNPIN BACK AND ROTATE 90 DEGREES IN ORDER TO DISENGAGE THE PLUNGER AS SHOWN IN FIGURE 1(ONLY THE MRS CONFIGURATION IS SHOWN BELOW). AT THIS STATE X-MON-PLUNPIN WILL NOT PROTRUDE THROUGH THE FRONT HOLE IN X-PM5-SHELF (FIGURE 2) YOU WILL NEED TO KEEP THIS IS MIND WHEN MOUNTING THE DEVICE. LOOSEN 4 X H-PHSCS-1420-12 SO THAT THEY ARE FLUSH WITH THE SURFACE OF X-PM5-SHELF.

FIGURE 2

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

X-MON-PLUNPIN

X-PM5-SHELF

PULL BACK AND ROTATE 90 DEGREES

FIGURE 1

X-MON-PLUNPIN DOES NOT PROTRUDE THROUGH THE FRONT HOLE IN X-PM5-SHELF

X-PM5-SHELF

4 X H-PHSCS-1420-12

4 X H-PHSCS-1420-12 FLUSH WITH THE SURFACE OF X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)PROJECT: 0438

NOTE: ENSURE THE MOUNTING RAIL/POST IS STABLE AND MOUNTED AS PER MANUFACTURERS INSTRUCTIONS

NOTE: ENSURE THE RAIL/POST IS NOT MOUNTED ABOVE A PATIENT

NOTE: THE LOAD RATING FOR THE PM5-_ IS 15 LBS, EXCEEDING THIS LIMIT CAN CAUSE FAILURE AND RESULT IN A SERIOUS INJURY

VRS: REFER TO THE USER MANUAL FOR VTA-8-32

ARS: REFER TO THE USER MANUAL FOR ATA-8-32

PLV/PLH: REFER TO THE USER MANUAL FOR PLV-8-32

GTA: REFER TO THE USER MANUAL FOR GTA-8-32

OHMEDA/DOVETAIL: REFER TO THE USER MANUAL FOR OHM-8-32

E25: REFER TO THE USER MANUAL FOR ETA-8-32

HSI: REFER TO THE USER MANUAL FOR STA-8-32

FRS: REFER TO THE USER MANUAL FOR FTA-8-32

MRS: REFER TO THE USER MANUAL FOR CPUMNTA-M

R200: REFER TO THE USER MANUAL FOR PC-2-8-32

MOUNTING ONTO PLATFORM

ONCE THE PRODUCT HAS BEEN MOUNTED ONTO THE PLATFORM COMPLETE THE STEP BELOW.

1. PULL X-MON-PLUNPIN BACK AND ROTATE 90 DEGREES IN ORDER TO DISENGAGE THE PLUNGER AS SHOWN IN FIGURE 1(ONLY THE MRS CONFIGURATION IS SHOWN BELOW). AT THIS STATE X-MON-PLUNPIN WILL NOT PROTRUDE THROUGH THE FRONT HOLE IN X-PM5-SHELF (FIGURE 2) YOU WILL NEED TO KEEP THIS IS MIND WHEN MOUNTING THE DEVICE. LOOSEN 4 X H-PHSCS-1420-12 SO THAT THEY ARE FLUSH WITH THE SURFACE OF X-PM5-SHELF.

FIGURE 2

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 1 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

SHELF[PM5-X]

SHELF[PM5-X]

PLUNGER PIN[X-MON-PLUNPIN]

4x PLASTIC SCREWS[H-PHSCS-1420-12]

4x PLASTIC SCREWS[H-PHSCS-1420-12] flush with the surface of SHELF

[PM5-X]

PLUNGER PIN [X-MON-PLUNPIN] does not protrude through

the front hole in SHELF [PM5-X]Pull back and

rotate 90 degrees

(Figure 3)

www.amico.com 14

4. Pull PLUNGER pin slightly back. Rotate 90 degrees again and release. This should re-engage the pin and allow protrusion through the SHELF and into the bottom slot on the VESA PLATE. If the PLUNGER pin does not engage, pull back, rotate slightly and retry. Figure 5 shows an exploded version (note the rail has been omitted for clarity).

5. Tighten 4 x SOCKET CAP SCREWS onto the VESA PLATE (Figure 6).

3. Slide VESA PLATE into SHELF (Figure 4). Note that the SHELF should be securely attached to the mounting platform at this stage and the PLUNGER PIN should be disengaged. To disengage the PLUNGER PIN, see instructions in “Mounting to Platform” section.

MONITOR (NOT PROVIDED BY AMICO)

X-MON-VESA-ADA

4 X M4 SCREWS

FIGURE 1

X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE1. PLACE MONITOR, FACE DOWN, ON A PADDED SURFACE AND ATTACH X-MON-VESA-ADA TO THE MONITOR USING THE 4 X M4 SCREWS (FIGURE 1).

2. SLIDE X-MON-VESA-ADA INTO X-PM5-SHELF (FIGURE 2). NOTE THAT THE X-PM5-SHELF SHOULD BE SECURELY ATTACHED TO THE MOUNTING PLATFORM BY THIS STAGE AND THE X-MON-PLUNPIN SHOULD BE DISENGAGED. TO DISENGAGE X-MON-PLUNPIN, SEE INSTRUCTIONS IN "MOUNTING TO THE PLATFORM" SECTION

FIGURE 2

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 2 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

(Figure 4)

Section 4: Mounting to Device

X-MON-PLUNPIN TO ENGAGE INTO THIS SLOT

X-MON-PLUNPIN

FIGURE 3

X-MON-VESA-ADA

X-PM5-SHELF

4 X H-PHSCS-1420-12

4 X H-PHSCS-1420-12 GOING THRUGH X-PM5-SHELF AND TIGHTENED ONTO X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE

3. PULL X- MON-PLUNPIN SLIGHTLY BACK, ROTATE 90 DEGREES AGAIN AND LET IT GO. THIS SHOULD RE-ENGAGE THE PIN AND IT MAKE GO THROUGH X-PM5-SHELF AND INTO THE BOTTOM SLOT ON X-MON-VESA-ADA. IF X-MON-PLUNPIN DOES NOT ENGAGE, PULL BACK, ROTATE SLIGHTLY AND RETRY. FIGURE 3 SHOWS AN EXPLODED VERSION (NOTE THE RAIL HAS BEEN OMITTED FOR CLARITY)

4. TIGHTEN 4 X H-PHSCS-1420-12 ONTO X-MON-VESA-ADA (FIGURE 4)

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 3 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

X-MON-PLUNPIN TO ENGAGE INTO THIS SLOT

X-MON-PLUNPIN

FIGURE 3

X-MON-VESA-ADA

X-PM5-SHELF

4 X H-PHSCS-1420-12

4 X H-PHSCS-1420-12 GOING THRUGH X-PM5-SHELF AND TIGHTENED ONTO X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE

3. PULL X- MON-PLUNPIN SLIGHTLY BACK, ROTATE 90 DEGREES AGAIN AND LET IT GO. THIS SHOULD RE-ENGAGE THE PIN AND IT MAKE GO THROUGH X-PM5-SHELF AND INTO THE BOTTOM SLOT ON X-MON-VESA-ADA. IF X-MON-PLUNPIN DOES NOT ENGAGE, PULL BACK, ROTATE SLIGHTLY AND RETRY. FIGURE 3 SHOWS AN EXPLODED VERSION (NOTE THE RAIL HAS BEEN OMITTED FOR CLARITY)

4. TIGHTEN 4 X H-PHSCS-1420-12 ONTO X-MON-VESA-ADA (FIGURE 4)

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 3 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

X-MON-PLUNPIN TO ENGAGE INTO THIS SLOT

X-MON-PLUNPIN

FIGURE 3

X-MON-VESA-ADA

X-PM5-SHELF

4 X H-PHSCS-1420-12

4 X H-PHSCS-1420-12 GOING THRUGH X-PM5-SHELF AND TIGHTENED ONTO X-MON-VESA-ADA

X-PM5-SHELF

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

MOUNTING THE DEVICE

3. PULL X- MON-PLUNPIN SLIGHTLY BACK, ROTATE 90 DEGREES AGAIN AND LET IT GO. THIS SHOULD RE-ENGAGE THE PIN AND IT MAKE GO THROUGH X-PM5-SHELF AND INTO THE BOTTOM SLOT ON X-MON-VESA-ADA. IF X-MON-PLUNPIN DOES NOT ENGAGE, PULL BACK, ROTATE SLIGHTLY AND RETRY. FIGURE 3 SHOWS AN EXPLODED VERSION (NOTE THE RAIL HAS BEEN OMITTED FOR CLARITY)

4. TIGHTEN 4 X H-PHSCS-1420-12 ONTO X-MON-VESA-ADA (FIGURE 4)

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 3 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

(Figure 5) (Figure 6)

PLUNGER PIN [X-MON-PLUNPIN]

to engage into this slot

4 x PLASTIC SCREWS[H-PHSCS-1420-12]

4 x PLASTIC SCREWS [H-PHSCS-1420-12]

going through SHELF [PM5-X] and tightened

onto VESA PLATE[MON-VESA-ADA]

SHELF[PM5-X]

VESA PLATE[MON-VESA-ADA]

SHELF[PM5-X]

VESA PLATE[MON-VESA-ADA]

PLUNGER PIN[X-MON-PLUNPIN]

SHELF[PM5-X]

15 Amico Accessories Inc.

The monitor can be rotated to a landscape/portrait orientation. To achieve this, follow the steps below.

NOTE: The mounting rail has been omitted from some figures for clarity.

INSTRUCTIONS

1. Loosen 4 x SOCKET CAP SCREW fully, disengage the PLUNGER pin by pulling it back and rotating 90 degrees (Figure 1).

2. Carefully slide the MONITOR (attached to VESA PLATE) from the SHELF (Figure 2).

3. Rotate the MONITOR to the desired orientation and slide the VESA PLATE back into the SHELF.

4. Follow steps 3 and 4 from the “Mounting Devices” section to complete adjustment.

Section 5: Adjustments

(Figure 1)(Figure 2)

(Figure 3)

X-MON-VESA-ADA

X-PM5-SHELF

FIGURE 1

FIGURE 2

MONITOR(NOT PROVIDED)

4 X H-PHSCS-1420-12

FIGURE 3

MONITOR(NOT PROVIDED)

X-PM5-SHELF

X-MON-VESA-ADA

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

ADJUSTMENTS

THE MONITOR ATTACHED CAN BE ROTATED TO A LANDSCAPE/PORTRAIT ORIENTATION. TO ACHEIVE THIS THE FOLLOWING STEPS MUST BE FOLLOWED:

1. LOOSEN 4 X H-PHSCS-1420-12 ALL THE WAY. DISENGAGE THE X-MON-PLUNPIN BY PULLING IT BACK AND ROTATING IT BY 90 DEGREES (FIGURE 1)

2. CAREFULLY, SLIDE THE MONITOR (ATTACHED TO X-MON-VESA-ADA) FROM THE X-PM5-SHELF. (FIGURE 2)

3. ROTATE THE MONITOR TO THE DESIRED ORIENTATION AND SLIDE X-MON-VESA-ADA BACK INTO X-PM5-SHELF. (FIGURE 3)

4. FOLLOW STEPS 3 AND 4 FROM THE "MOUNTING THE DEVICE" SECTION TO COMPLETE THE ADJUSTMENT.

NOTE: THE MOUNTING RAIL HAS BEEN OMITTED FROM SOME FIGURES FOR CLARITY

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 4 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

X-MON-VESA-ADA

X-PM5-SHELF

FIGURE 1

FIGURE 2

MONITOR(NOT PROVIDED)

4 X H-PHSCS-1420-12

FIGURE 3

MONITOR(NOT PROVIDED)

X-PM5-SHELF

X-MON-VESA-ADA

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

ADJUSTMENTS

THE MONITOR ATTACHED CAN BE ROTATED TO A LANDSCAPE/PORTRAIT ORIENTATION. TO ACHEIVE THIS THE FOLLOWING STEPS MUST BE FOLLOWED:

1. LOOSEN 4 X H-PHSCS-1420-12 ALL THE WAY. DISENGAGE THE X-MON-PLUNPIN BY PULLING IT BACK AND ROTATING IT BY 90 DEGREES (FIGURE 1)

2. CAREFULLY, SLIDE THE MONITOR (ATTACHED TO X-MON-VESA-ADA) FROM THE X-PM5-SHELF. (FIGURE 2)

3. ROTATE THE MONITOR TO THE DESIRED ORIENTATION AND SLIDE X-MON-VESA-ADA BACK INTO X-PM5-SHELF. (FIGURE 3)

4. FOLLOW STEPS 3 AND 4 FROM THE "MOUNTING THE DEVICE" SECTION TO COMPLETE THE ADJUSTMENT.

NOTE: THE MOUNTING RAIL HAS BEEN OMITTED FROM SOME FIGURES FOR CLARITY

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 4 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

X-MON-VESA-ADA

X-PM5-SHELF

FIGURE 1

FIGURE 2

MONITOR(NOT PROVIDED)

4 X H-PHSCS-1420-12

FIGURE 3

MONITOR(NOT PROVIDED)

X-PM5-SHELF

X-MON-VESA-ADA

CUSTOMER DRAWINGFOR USE WITH: PM5-_(__)

PROJECT: 0438

ADJUSTMENTS

THE MONITOR ATTACHED CAN BE ROTATED TO A LANDSCAPE/PORTRAIT ORIENTATION. TO ACHEIVE THIS THE FOLLOWING STEPS MUST BE FOLLOWED:

1. LOOSEN 4 X H-PHSCS-1420-12 ALL THE WAY. DISENGAGE THE X-MON-PLUNPIN BY PULLING IT BACK AND ROTATING IT BY 90 DEGREES (FIGURE 1)

2. CAREFULLY, SLIDE THE MONITOR (ATTACHED TO X-MON-VESA-ADA) FROM THE X-PM5-SHELF. (FIGURE 2)

3. ROTATE THE MONITOR TO THE DESIRED ORIENTATION AND SLIDE X-MON-VESA-ADA BACK INTO X-PM5-SHELF. (FIGURE 3)

4. FOLLOW STEPS 3 AND 4 FROM THE "MOUNTING THE DEVICE" SECTION TO COMPLETE THE ADJUSTMENT.

NOTE: THE MOUNTING RAIL HAS BEEN OMITTED FROM SOME FIGURES FOR CLARITY

5 4 3 2 1

DESCRIPTION:

PART NO:

SCALE: DRAWN BY:

CHECKED BY:

SHT. OF

DRAWING NO:NTS 4 4

PRIVATE AND CONFIDENTIALTHIS PRINT IS PROPERTY OF AMICO ACCESSORIES AND IS LOANED IN CONFIDENCE SUBJECT TO RETURN UPON REQUEST AND WITH THE UNDERSTANDING THAT NO COPIES ARE TO BE MADE WITHOUT THE CONSENT OF AMICO ACCESSORIES

ALL RIGHTS TO DESIGN OR INVENTION ARE RESERVEDDATE:DATE:

Assembly of 5" Patient Monitor Shelf

SK JAN/9/2015EC JAN/9/2015

85 Fulton WayRichmond Hill, OntarioL4B 2N4, CanadaToll Free: 1.877.264.2697 (T)Tel: (905) 763.7778Fax: (905) 763.8587

PM5-_(__)

20150109-E3349

PROJECTION

www.amico.com

MONITOR(Not Provided)

MONITOR(Not Provided)

SHELF[PM5-X]

SHELF[PM5-X]

VESA PLATE[MON-VESA-ADA]

VESA PLATE[MON-VESA-ADA]

4 x PLASTIC SCREWS[H-PHSCS-1420-12]

www.amico.com 16

Troubleshooting Guide

Maintenance

Section 6: Maintenance and Troubleshooting

Symptoms Possible Cause Solution

Device feels loose 4 x M4 screws are loose Tighten the 4 x M4 screws through MON-VESA-ADA onto the device

MON-VESA-ADA feels loose 4 x plastic screws are not tightened onto MON-VESA-ADA

Follow step 4 in the “Mounting to Device” section

Plunger pin is not engaged Follow step 3 in the “Mounting to Device” section

Area Maintenance Period

Tighten 4 x plastic screws onto MON-VESA-ADA

3 monthsEnsure plunger pin is engaged

17 Amico Accessories Inc.

Section 6: Cleaning

No AcetoneAcetone is a colorless, mobile, flamable liquid

No TrichloroethyleneTrichloroethylene is a chlorinated hydrocarbon commonly used a ans individual solvent

Acetone Trichloroethylene

WARNING: THE CLEANING CHEMICALS AND METHODS BELOW ARE NOT MEANT FOR CONTROLLING ANY INFECTIONS. IT SHALL BE THE RESPONSIBILITY OF THE HOSPITAL OR THE HOSPITAL’S INFECTION CONTROL OFFICER TO SANITIZE THE EQUIPMENT.

WARNING: PLEASE DO NOT SPRAY ANY CHEMICAL DIRECTLY ONTO THE PRODUCT. APPLY ONTO A SOFT CLOTH AND WIPE CLEAN TO PREVENT CHEMICALS GETTING INTO THE PRODUCT.

The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). The surface finish will be permanently damaged by strong chemical and solvent such as acetone and trichloroethylene. Steel wool or other abrasive material should never be used. Damaged caused by the use of unapproved substances or processes will not be warranted. It is recommended that you test any cleaning solution on a small area of the product that is not visible to verify compatibility. Never submerge the product and do not allow liquids to enter it. Wipe any cleaning agents off the product immediately using a water-dampened cloth. Dry the product thoroughly after..

www.amico.com 18 www.amico.com www.amico.com

Amico Accessories Inc. warrants all mounting accessories to be free from defects in material and workmanship for a period of twelve (12) months from the date of shipment. Within this period Amico Accessories Inc. will repair or replace any part which is proven to be defective.

Amico Accessories Inc. will warrant its materials to be free from defect for an additional period of four (4) years, (five [5] years from the date of shipment). Within this period, Amico Accessories Inc. will replace any part which is proven to be defective, at no charge. Shipping and Installation costs after the first twelve (12) months will be borne by the Customer.

This warranty is valid only when the product has been properly installed according to Amico Accessories Inc. specifications, used in a normal manner and serviced according to factory recommendations. It does not cover products that are not manufactured by Amico Accessories Inc. It does not cover failures due to damage which occurs in shipments or failures which result from accidents, misuse, abuse, neglect, mishandling, alteration, misapplication or damage that may be attributable to acts of God.

Amico Accessories Inc. shall not be liable for incidental or consequential damages resulting from use of equipment.

All claims for warranty must first be approved by Amico Accessories Inc. A valid Return Goods Authorization (RGA) number must be obtained from Amico Accessories Inc. prior to commencement of any service work. Warranty work, which has not been pre-authorized by Amico Accessories Inc., will not be reimbursed.

AMICO ACCESSORIES INC. DOES NOT HONOR VERBAL STATEMENTS CONCERNING THE WARRANTY.

The distributor and/or dealer are not sanctioned to create verbal warranties about the product described in this agreement. Any statements will not be honored or be made part of the agreement of sale. This document is the final complete and exclusive terms of the agreement.

THIS WARRANTY IS INCLUSIVE AND REPLACES ALL OTHER WARRANTIES.

Amico Accessories Inc. shall not, under any circumstances be liable for incidental or consequential damages including, but not limited to, profit, loss of sales or injuries to person(s) or property. Correction of noncompliance as noted above will result in completion of all liabilities of Amico Accessories Inc., whether based on agreement, neglect or changed materials, designs or specifications without notice.

All claims for warranty must first be approved by Amico Accessories Inc. Service Department: [email protected] or 1.877.264.2697). A valid Return Goods Authorization number must be obtained from Amico Accessories Inc. prior to commencement of any warranty claim.

Amico Accessories Inc. 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada71 East Industry Court, Deer Park, NY 11729, USA

Tel: 905.763.7778 | Fax: 905.763.8587

Warranty Policy - Equipment Mounting Solutions

www.amico.com

AA-IM-PM5 07.06.2018

Amico Accessories Inc. | 85 Fulton Way, Richmond Hill, ON L4B 2N4, CanadaToll Free Tel: 1.877.264.2697 | Tel: 905.763.7778 | Fax: 905.763.8587Email: [email protected] | www.amico.com