DETALET
Skema e Mbrojtjes nga Mbitensionet
FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
Community Development
Initiatives
STACIONI I POMPIMIT
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN
Installation calculation report
Content
1 Project description ................................................................................................................. 3
1.1 Project general settings ................................................................................................................... 3
1.2 Settings for wiring device calculation............................................................................................. 3
1.3 List of loads ....................................................................................................................................... 3
2 Installation general design .................................................................................................... 3
2.1 List of devices ................................................................................................................................... 3
3 Calculation notes ................................................................................................................... 4
3.1 Source circuits ...................................................................................... Error! Bookmark not defined.
3.2 Generic load circuits ............................................................................. Error! Bookmark not defined.
3.3 Motor starter combination ................................................................................................................ 5
1 Project description
1.1 Project general settings Installation standard IEC60364
Calculation standard TR50480 Circuit breaker standard IEC 60947-2 Frequency 50 Hz
1.2 Settings for wiring device calculation Maximal CSA 300 mm²
1.3 List of loads
1.3.1 Generic loads
Name Sr (kVA) Pr (kW) Ir (A) Cos Nbr Polarity Non linear load THDi 3 (%)
TABELA 11.8 10 17 0.85 5 3Ph+N No 0
1.3.2 Motor loads
Name Sr (kVA) Pr (kW) Ir (A) Cos Nbr Polarity Non linear load THDi 3 (%)
P1 38.1 32.8 55 0.86 1 3Ph No 0 P2 38.1 32.8 55 0.86 1 3Ph No 0 P3 67.2 57.8 97 0.86 1 3Ph No 0 P4 67.2 57.8 97 0.86 1 3Ph No 0
2 Installation general design
2.1 List of devices
2.1.1 Circuit breaker
Name Nbr Range - Designation Rating (A) Poles Trip unit/Curve QA 0 1 Compact NSX - NSX400F 400 4P4d Micrologic 5.3 A QA 3 1 Compact NSX - NSX100F 100 3P3d Micrologic 2.2 M QA 3 (1) 1 Compact NSX - NSX100F 100 3P3d Micrologic 2.2 M QA 3 (2) 1 Compact NSX - NSX160F 160 3P3d MA QA 3 (2) (1) 1 Compact NSX - NSX160F 160 3P3d MA QA 4 5 Acti9 iC60 - iC60N 20 4P4d C
2.1.2 Cable schedule
Name Nbr
Incomer Feeder Type L (m) L1/L2/L3 N PE/PEN
WD 0 1 TA 0 QA 0 Multi-core 150 2x185 Copper 2x185 Copper 2x95 Copper WD 3 (1) 1 QA 3 (1) P2 Multi-core 90 1x25 Copper 1x25 Copper WD 3 1 QA 3 P1 Multi-core 90 1x25 Copper 1x25 Copper WD 4 5 QA 4 TABELA Multi-core 10 1x2.5 Copper 1x2.5 Copper 1x2.5 Copper WD 3 (2) (1) 1 QA 3 (2) (1) P4 Multi-core 10 1x50 Copper 1x50 Copper WD 3 (2) 1 QA 3 (2) P3 Multi-core 10 1x50 Copper 1x50 Copper
3 Calculation notes Selected phase Cross section area 2x185 mm² Core Copper Iz under real conditions 534 A Selected neutral Cross section area 2x185 mm² Core Copper Iz under real conditions 534 A Selected PE Cross section area 2x95 mm² Core Copper
Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min
Operating mode Normal (kA) 7.05 6.11 7.05 3.62 3.46 4.17 0.00
Synthesis for all operating mode (kA) 7.05 6.11 7.05 3.62 3.46 4.17 0.00
Calculation results in accordance with CENELEC technical report TR50480. All assumptions and device choices are the user's responsibility. Circuit breaker QA 0 Ib 361 A
Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX400F Circuit breaker rating 400 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 4P4d Trip unit designation Micrologic 5.3 A Trip unit rating 400 A Long delay settings Ir 361 A Tr 16 s Short delay settings Isd current 2527 A Tsd 0 s Instantaneous tripping Ii current 4800 A
Discrimination Results
UpStream Discrimination Limit
Operating mode Normal
U3L (%) 1.769 1.769
UL1L2 (%) 2.043 2.043
UL2L3 (%) 2.043 2.043
UL3L1 (%) 2.043 2.043
UL1N (%) 1.769 1.769
UL2N (%) 1.769 1.769
UL3N (%) 1.769 1.769
3.1 Motor starter combination
3.1.1 Circuit Motor Load 3
Circuit breaker QA 3 Ib NA
Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX100F Circuit breaker rating 100 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation Micrologic 2.2 M Trip unit rating 100 A Long delay settings Ir 60 A Tr 5 s Short delay settings Isd current 780 A Tsd 0.03 s Instantaneous tripping Ii current 1500 A
Discrimination Results
UpStream Discrimination Limit
Operating mode Normal
QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d
Full Discrimination
Contactor LC1D65A
Designation LC1D65A
Type of coordination T1
Cable WD 3 Parameters Length 90 m Max length 270 m Installation method 70
D1 Multi-core cable in conduit or in cable ducting in the ground
Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 55 A Sizing constraint Voltage drop Sizing Information The CSA of cable WD 3 has been
increased from 16 to 25 to comply with the voltage drop in the circuit. Sized with Ir
Correction factors
Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1
Selected phase Cross section area 1x25 mm² Core Copper Iz under real conditions 82 A Selected PE Cross section area 1x25 mm² Core Copper
Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min
Operating mode Normal (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00
Synthesis for all operating mode (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00
Calculation results in accordance with CENELEC technical report TR50480. All assumptions and device choices are the user's responsibility. Asynchronous LV Motor P1 Startup type Direct U 400 V Mechanical power 30 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 55 A Sr for sizing 38.1 kVA Pr for sizing 32.8 kW
cos 0.86
Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN
Operating mode Normal (A) 55.000 55.000 55.000 0
Synthesis for all operating mode (A) 55.000 55.000 55.000 0 Voltage drop Cumulated from upstream Circuit
Operating mode Normal
U3L (%) 3.495 1.725
UL1L2 (%) 4.035 1.992
UL2L3 (%) 4.035 1.992
UL3L1 (%) 4.035 1.992
UL1N (%) 1.769 0.000
UL2N (%) 1.769 0.000
UL3N (%) 1.769 0.000
Startup Voltage drop
UStartUp 6.631
3.1.2 Circuit Motor Load 3 (1)
Circuit breaker QA 3 (1) Ib NA
Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX100F Circuit breaker rating 100 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation Micrologic 2.2 M Trip unit rating 100 A Long delay settings Ir 60 A Tr 5 s Short delay settings Isd current 780 A Tsd 0.03 s Instantaneous tripping Ii current 1500 A
Discrimination Results
UpStream Discrimination Limit
Operating mode Normal
QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d
Full Discrimination
Contactor LC1D65A
Designation LC1D65A
Type of coordination T1
Cable WD 3 (1) Parameters Length 90 m Max length 270 m Installation method 70
D1 Multi-core cable in conduit or in cable ducting in the ground
Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 %
Ib 55 A Sizing constraint Voltage drop Sizing Information The CSA of cable WD 3 (1) has been
increased from 16 to 25 to comply with the voltage drop in the circuit. Sized with Ir
Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1 Selected phase Cross section area 1x25 mm² Core Copper Iz under real conditions 82 A Selected PE Cross section area 1x25 mm² Core Copper
Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min
Operating mode Normal (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00 Asynchronous LV Motor P2 Startup type Direct U 400 V Mechanical power 30 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 55 A Sr for sizing 38.1 kVA Pr for sizing 32.8 kW
cos 0.86
Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN
Operating mode Normal (A) 55.000 55.000 55.000 0 Synthesis for all operating mode (A) 55.000 55.000 55.000 0 Voltage drop Cumulated from upstream Circuit Operating mode Normal
U3L (%) 3.495 1.725
UL1L2 (%) 4.035 1.992
UL2L3 (%) 4.035 1.992
UL3L1 (%) 4.035 1.992
UL1N (%) 1.769 0.000
UL2N (%) 1.769 0.000
UL3N (%) 1.769 0.000
Startup Voltage drop
UStartUp 6.631
3.1.3 Circuit Motor Load 3 (2)
Circuit breaker QA 3 (2) Ib NA
Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX160F Circuit breaker rating 160 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation MA Trip unit rating 100 A Long delay settings Ir 100 A Tr NA Short delay settings Isd current 1400 A Tsd NA Instantaneous tripping Ii current NA
Discrimination Results
UpStream Discrimination Limit
Operating mode Normal
QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d
4800 A
Contactor LC1D115
Designation LC1D115
Type of coordination T1
Thermal relay LRD4367
Designation LRD4367
Ir 97
Cable WD 3 (2) Parameters Length 10 m Max length 107 m Installation method 70
D1 Multi-core cable in conduit or in cable ducting in the ground
Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 97 A Sizing constraint Iz
Sizing Information Sized with Ir Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1
Selected phase Cross section area 1x50 mm² Core Copper Iz under real conditions 116 A Selected PE Cross section area 1x50 mm² Core Copper Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min Operating mode Normal (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Asynchronous LV Motor P3 Startup type Direct U 400 V Mechanical power 55 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 97 A Sr for sizing 67.2 kVA Pr for sizing 57.8 kW
cos 0.86
Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN Operating mode Normal (A) 97.000 97.000 97.000 0 Synthesis for all operating mode (A) 97.000 97.000 97.000 0 Voltage drop Cumulated from upstream Circuit
Operating mode Normal
U3L (%) 1.947 0.178
UL1L2 (%) 2.248 0.205
UL2L3 (%) 2.248 0.205
UL3L1 (%) 2.248 0.205
UL1N (%) 1.769 0.000
UL2N (%) 1.769 0.000
UL3N (%) 1.769 0.000
Startup Voltage drop
UStartUp 4.146
3.1.4 Circuit Motor Load 3 (2) (1)
Circuit breaker QA 3 (2) (1) Ib NA
Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX160F Circuit breaker rating 160 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation MA Trip unit rating 100 A Long delay settings Ir 100 A Tr NA Short delay settings Isd current 1400 A Tsd NA Instantaneous tripping Ii current NA Discrimination Results
UpStream Discrimination Limit
Operating mode Normal
QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d
4800 A
Contactor LC1D115
Designation LC1D115
Type of coordination T1
Thermal relay LRD4367
Designation LRD4367
Ir 97
Cable WD 3 (2) (1) Parameters Length 10 m Max length 107 m Installation method 70
D1 Multi-core cable in conduit or in cable ducting in the ground
Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 97 A Sizing constraint Iz Sizing Information Sized with Ir Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1
Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1
Selected phase Cross section area 1x50 mm² Core Copper Iz under real conditions 116 A Selected PE Cross section area 1x50 mm² Core Copper Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min Operating mode Normal (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Asynchronous LV Motor P4 Startup type Direct U 400 V Mechanical power 55 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 97 A Sr for sizing 67.2 kVA Pr for sizing 57.8 kW
cos 0.86
Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN Operating mode Normal (A) 97.000 97.000 97.000 0 Synthesis for all operating mode (A) 97.000 97.000 97.000 0 Voltage drop Cumulated from upstream Circuit Operating mode Normal
U3L (%) 1.947 0.178
UL1L2 (%) 2.248 0.205
UL2L3 (%) 2.248 0.205
UL3L1 (%) 2.248 0.205
UL1N (%) 1.769 0.000
UL2N (%) 1.769 0.000
UL3N (%) 1.769 0.000
Startup Voltage drop
UStartUp 4.146
Operating mode Normal (kA) 5.96 5.16 5.11 3.68 3.59 4.25 0.00 Synthesis for all operating mode (kA) 5.96 5.16 5.11 3.68 3.59 4.25 0.00
5
A
C
4
B
1
1 54
A
B
C
3'3
3'3
2988.9
2303.64
2332.8
SONDA
TOKZUESE 2.0m
TE RRUFEPRITESI
SHIRIT I ZINKUAR
Fe/Zn 20X3mm2
Shirit i ZinguarFe/Zn25x4mm²
Shirit i ZinguarFe/Zn25x4mm²
Shirit i ZinguarFe/Zn25x4mm²
Shiriti i salduar
per armature
cdo 2-3m
Shiriti i salduar
per armature
cdo 2-3m
Shiriti i salduar
per armature
cdo 2-3m
SONDA
TOKZUESE 2.0m
SONDA
TOKZUESE 2.0m
SONDA
TOKZUESE 2.0m
SONDA
TOKZUESE 2.0m
TE RRUFEPRITESI
SHIRIT I ZINKUAR
Fe/Zn 20X3mm2
TE RRUFEPRITESI
SHIRIT I ZINKUAR
Fe/Zn 20X3mm2
TE RRUFEPRITESI
SHIRIT I ZINKUAR
Fe/Zn 20X3mm2
TE RRUFEPRITESI
SHIRIT I ZINKUAR
Fe/Zn 20X3mm2
BAZA E THEMELEVE
Tokëzimi i rrufepritesit
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
STACIONI I POMPIMIT
Community Development
Initiatives
LIPIJAN
20.00 %20.00 %
1410.00
450.00 400.0030.00
530.00
450.00 400.0030.00
1410.00
320.00
410.00
340.00
730.00
-0.50
-0.15-1.35
-1.35
-1.35
-1.35
-1.50
SHUKO PRIZA
IP
KM
&K
SH
P
KS
H O
KKK
BAZA E THEMELEVE
Instalimet Elektrike
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
Community Development
Initiatives
STACIONI I POMPIMIT
LIPIJAN
KULMI
kulm i pjerrtë i=10%
s hori
zont
ale=
17.2
1 m
2
kulm i pjerrtë i=10%
s hori
zont
ale=
38.9
0 m
2
kulm i pjerrtë i=10%
s hori
zont
ale=
5.64
m2
2
2
3
3
A A
B B
1
1
Mbajtësi i shiritit
1 m
çdo
Mbajtësi i shiritit
Mbajtësi i shiritit
1 m
çdo
Mbajtësi i shiritit
Shirit i ZinguarFe/Zn20x3mm²
Shirit i ZinguarFe/Zn20x3mm²
Shirit i ZinguarFe/Zn20x3mm²
BAZA E THEMELEVE
Instalimi i rrufepritesit
FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
Community Development
Initiatives
STACIONI I POMPIMIT
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN
FUQIA E NJEKOHESHME (kW) 154.8kWPnj
In=Pnj / (1.73*400) (A)
223.69 AIn
KUADRI MATES - KM dhe KUADRI SHPERNDARES I POMPAVE
26.0 26.0
KABLLO - PP00 (mm²) 4x25
lidhja matese
Cu 50
m
m
Fe-Z
n 25x4 m
m
400 A
KKK
tokëzimi ne themel
Nga rrjeti publik(TS)
KABLLO NËNTOKESORE
PP00 2x4x185mm²(Cu)+2x95 mm²
KUADRI KRYESORE KYQES- KKK
55.0
4x50
55.0
4x50
55.0
4x50
10
5x6
172.0 kWPins
4x25
KOADROT SHPRENDARESE
KKK dhe KM-SH
INSTALIME ELEKTRIKE
(Furnizmi i ipompave dhe objektit me
energji elektrike)FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
Community Development
Initiatives
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN
STACIONI I POMPIMIT
FUQIA E NJEKOHESHME (kW)
KABLLO - PP00 (mm²)
FUQIA E INSTALUAR (kW)
( 5 X 6 )
7.50 kW
10.0 kW
Pi
Pnj
Pnj=Pi * k, k=0.75
INTENSITETI (A)- Pnj / (1.73*400)
10.83A
I
KUADRI SHPERNDARES O (Objekti)
BOJLER
FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
KOADROT SHPRENDARESE
KSH-O(Objekti)
Community Development
Initiatives
STACIONI I POMPIMIT
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN
Residual - current protective devicesRCCB
RCCB
IV Përfshin pajisjet në furizim të përçuesve
III Përfshin tërë qarkun e lidhut sipas figurës
II Pajisjet që duhet të kyçën në mënyrë permanente përmes përçuesve
I Pajisjet të cilat kërkojn veçanarisht nivel të lartë të mbrojtjes
Kategoria e mbitensioneve (IEC 60664-1/VDE 0110 pjesa I) dhe niveli i tensionit impulsiv i durimit
Pajisjet
elektronike
(computer)
Pajisjet elektrike
I
1.5kV
II
2.5kV
III
4kV
D
6kV
Tensioni impuliv i
nivelit të durimit
Matësi i energjisë
CB
Shkarkuesi i
mbitensionit i
kategorisë
AC 400/230V
IV
Niveli i
mbitensioneve
Skema e mbrojtjes nga mbitensionet
LLOGARITJA E KABLLOVE FURNIZUESE
Ramjet e Tensionit
FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
Community Development
Initiatives
STACIONI I POMPIMIT
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN
FAZA / PHASE
PROJEKTI / PROJECT
Data/Date
Përpjesa/Scale
1:50
PROJKETI KRYESOR
VENDI I NDËRTIMIT
LOCATION
PROJEKTUES
PROJECT DESIGN
INVESTITORI
INVESTOR
OBJEKTI
BUILDING
LLOGARITJA E KABLLOVE FURNIZUESE
Paisjet Elektrike
Community Development
Initiatives
STACIONI I POMPIMIT
INSTALIME ELEKTRIKE
(Furnizmi i pompave dhe objektit me
energji elektrike)
LIPIJAN