20
DETALET Skema e Mbrojtjes nga Mbitensionet FAZA / PHASE PROJEKTI / PROJECT Data/Date 3sUSMHVD6FDOH 1:50 PROJKETI KRYESOR 9(1', , 1'ノ57,0,7 LOCATION PROJEKTUES PROJECT DESIGN INVESTITORI INVESTOR OBJEKTI BUILDING Community Development Initiatives STACIONI I POMPIMIT INSTALIME ELEKTRIKE (Furnizmi i pompave dhe objektit me energji elektrike) LIPIJAN

Installation calculation report

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation calculation report

DETALET

Skema e Mbrojtjes nga Mbitensionet

FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

Community Development

Initiatives

STACIONI I POMPIMIT

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN

Page 2: Installation calculation report

Installation calculation report

Page 3: Installation calculation report

Content

1 Project description ................................................................................................................. 3

1.1 Project general settings ................................................................................................................... 3

1.2 Settings for wiring device calculation............................................................................................. 3

1.3 List of loads ....................................................................................................................................... 3

2 Installation general design .................................................................................................... 3

2.1 List of devices ................................................................................................................................... 3

3 Calculation notes ................................................................................................................... 4

3.1 Source circuits ...................................................................................... Error! Bookmark not defined.

3.2 Generic load circuits ............................................................................. Error! Bookmark not defined.

3.3 Motor starter combination ................................................................................................................ 5

Page 4: Installation calculation report

1 Project description

1.1 Project general settings Installation standard IEC60364

Calculation standard TR50480 Circuit breaker standard IEC 60947-2 Frequency 50 Hz

1.2 Settings for wiring device calculation Maximal CSA 300 mm²

1.3 List of loads

1.3.1 Generic loads

Name Sr (kVA) Pr (kW) Ir (A) Cos Nbr Polarity Non linear load THDi 3 (%)

TABELA 11.8 10 17 0.85 5 3Ph+N No 0

1.3.2 Motor loads

Name Sr (kVA) Pr (kW) Ir (A) Cos Nbr Polarity Non linear load THDi 3 (%)

P1 38.1 32.8 55 0.86 1 3Ph No 0 P2 38.1 32.8 55 0.86 1 3Ph No 0 P3 67.2 57.8 97 0.86 1 3Ph No 0 P4 67.2 57.8 97 0.86 1 3Ph No 0

2 Installation general design

2.1 List of devices

2.1.1 Circuit breaker

Name Nbr Range - Designation Rating (A) Poles Trip unit/Curve QA 0 1 Compact NSX - NSX400F 400 4P4d Micrologic 5.3 A QA 3 1 Compact NSX - NSX100F 100 3P3d Micrologic 2.2 M QA 3 (1) 1 Compact NSX - NSX100F 100 3P3d Micrologic 2.2 M QA 3 (2) 1 Compact NSX - NSX160F 160 3P3d MA QA 3 (2) (1) 1 Compact NSX - NSX160F 160 3P3d MA QA 4 5 Acti9 iC60 - iC60N 20 4P4d C

2.1.2 Cable schedule

Name Nbr

Incomer Feeder Type L (m) L1/L2/L3 N PE/PEN

WD 0 1 TA 0 QA 0 Multi-core 150 2x185 Copper 2x185 Copper 2x95 Copper WD 3 (1) 1 QA 3 (1) P2 Multi-core 90 1x25 Copper 1x25 Copper WD 3 1 QA 3 P1 Multi-core 90 1x25 Copper 1x25 Copper WD 4 5 QA 4 TABELA Multi-core 10 1x2.5 Copper 1x2.5 Copper 1x2.5 Copper WD 3 (2) (1) 1 QA 3 (2) (1) P4 Multi-core 10 1x50 Copper 1x50 Copper WD 3 (2) 1 QA 3 (2) P3 Multi-core 10 1x50 Copper 1x50 Copper

Page 5: Installation calculation report

3 Calculation notes Selected phase Cross section area 2x185 mm² Core Copper Iz under real conditions 534 A Selected neutral Cross section area 2x185 mm² Core Copper Iz under real conditions 534 A Selected PE Cross section area 2x95 mm² Core Copper

Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min

Operating mode Normal (kA) 7.05 6.11 7.05 3.62 3.46 4.17 0.00

Synthesis for all operating mode (kA) 7.05 6.11 7.05 3.62 3.46 4.17 0.00

Calculation results in accordance with CENELEC technical report TR50480. All assumptions and device choices are the user's responsibility. Circuit breaker QA 0 Ib 361 A

Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX400F Circuit breaker rating 400 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 4P4d Trip unit designation Micrologic 5.3 A Trip unit rating 400 A Long delay settings Ir 361 A Tr 16 s Short delay settings Isd current 2527 A Tsd 0 s Instantaneous tripping Ii current 4800 A

Discrimination Results

UpStream Discrimination Limit

Operating mode Normal

U3L (%) 1.769 1.769

UL1L2 (%) 2.043 2.043

UL2L3 (%) 2.043 2.043

UL3L1 (%) 2.043 2.043

UL1N (%) 1.769 1.769

UL2N (%) 1.769 1.769

UL3N (%) 1.769 1.769

Page 6: Installation calculation report

3.1 Motor starter combination

3.1.1 Circuit Motor Load 3

Circuit breaker QA 3 Ib NA

Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX100F Circuit breaker rating 100 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation Micrologic 2.2 M Trip unit rating 100 A Long delay settings Ir 60 A Tr 5 s Short delay settings Isd current 780 A Tsd 0.03 s Instantaneous tripping Ii current 1500 A

Discrimination Results

UpStream Discrimination Limit

Operating mode Normal

QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d

Full Discrimination

Contactor LC1D65A

Designation LC1D65A

Type of coordination T1

Cable WD 3 Parameters Length 90 m Max length 270 m Installation method 70

D1 Multi-core cable in conduit or in cable ducting in the ground

Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 55 A Sizing constraint Voltage drop Sizing Information The CSA of cable WD 3 has been

increased from 16 to 25 to comply with the voltage drop in the circuit. Sized with Ir

Correction factors

Page 7: Installation calculation report

Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1

Selected phase Cross section area 1x25 mm² Core Copper Iz under real conditions 82 A Selected PE Cross section area 1x25 mm² Core Copper

Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min

Operating mode Normal (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00

Synthesis for all operating mode (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00

Calculation results in accordance with CENELEC technical report TR50480. All assumptions and device choices are the user's responsibility. Asynchronous LV Motor P1 Startup type Direct U 400 V Mechanical power 30 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 55 A Sr for sizing 38.1 kVA Pr for sizing 32.8 kW

cos 0.86

Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN

Operating mode Normal (A) 55.000 55.000 55.000 0

Synthesis for all operating mode (A) 55.000 55.000 55.000 0 Voltage drop Cumulated from upstream Circuit

Operating mode Normal

Page 8: Installation calculation report

U3L (%) 3.495 1.725

UL1L2 (%) 4.035 1.992

UL2L3 (%) 4.035 1.992

UL3L1 (%) 4.035 1.992

UL1N (%) 1.769 0.000

UL2N (%) 1.769 0.000

UL3N (%) 1.769 0.000

Startup Voltage drop

UStartUp 6.631

3.1.2 Circuit Motor Load 3 (1)

Circuit breaker QA 3 (1) Ib NA

Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX100F Circuit breaker rating 100 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation Micrologic 2.2 M Trip unit rating 100 A Long delay settings Ir 60 A Tr 5 s Short delay settings Isd current 780 A Tsd 0.03 s Instantaneous tripping Ii current 1500 A

Discrimination Results

UpStream Discrimination Limit

Operating mode Normal

QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d

Full Discrimination

Contactor LC1D65A

Designation LC1D65A

Type of coordination T1

Cable WD 3 (1) Parameters Length 90 m Max length 270 m Installation method 70

D1 Multi-core cable in conduit or in cable ducting in the ground

Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 %

Page 9: Installation calculation report

Ib 55 A Sizing constraint Voltage drop Sizing Information The CSA of cable WD 3 (1) has been

increased from 16 to 25 to comply with the voltage drop in the circuit. Sized with Ir

Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1 Selected phase Cross section area 1x25 mm² Core Copper Iz under real conditions 82 A Selected PE Cross section area 1x25 mm² Core Copper

Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min

Operating mode Normal (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 1.68 0.00 1.16 0.00 Asynchronous LV Motor P2 Startup type Direct U 400 V Mechanical power 30 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 55 A Sr for sizing 38.1 kVA Pr for sizing 32.8 kW

cos 0.86

Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN

Operating mode Normal (A) 55.000 55.000 55.000 0 Synthesis for all operating mode (A) 55.000 55.000 55.000 0 Voltage drop Cumulated from upstream Circuit Operating mode Normal

U3L (%) 3.495 1.725

UL1L2 (%) 4.035 1.992

UL2L3 (%) 4.035 1.992

UL3L1 (%) 4.035 1.992

Page 10: Installation calculation report

UL1N (%) 1.769 0.000

UL2N (%) 1.769 0.000

UL3N (%) 1.769 0.000

Startup Voltage drop

UStartUp 6.631

3.1.3 Circuit Motor Load 3 (2)

Circuit breaker QA 3 (2) Ib NA

Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX160F Circuit breaker rating 160 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation MA Trip unit rating 100 A Long delay settings Ir 100 A Tr NA Short delay settings Isd current 1400 A Tsd NA Instantaneous tripping Ii current NA

Discrimination Results

UpStream Discrimination Limit

Operating mode Normal

QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d

4800 A

Contactor LC1D115

Designation LC1D115

Type of coordination T1

Thermal relay LRD4367

Designation LRD4367

Ir 97

Cable WD 3 (2) Parameters Length 10 m Max length 107 m Installation method 70

D1 Multi-core cable in conduit or in cable ducting in the ground

Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 97 A Sizing constraint Iz

Page 11: Installation calculation report

Sizing Information Sized with Ir Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1 Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1

Selected phase Cross section area 1x50 mm² Core Copper Iz under real conditions 116 A Selected PE Cross section area 1x50 mm² Core Copper Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min Operating mode Normal (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Asynchronous LV Motor P3 Startup type Direct U 400 V Mechanical power 55 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 97 A Sr for sizing 67.2 kVA Pr for sizing 57.8 kW

cos 0.86

Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN Operating mode Normal (A) 97.000 97.000 97.000 0 Synthesis for all operating mode (A) 97.000 97.000 97.000 0 Voltage drop Cumulated from upstream Circuit

Operating mode Normal

U3L (%) 1.947 0.178

UL1L2 (%) 2.248 0.205

UL2L3 (%) 2.248 0.205

UL3L1 (%) 2.248 0.205

UL1N (%) 1.769 0.000

UL2N (%) 1.769 0.000

UL3N (%) 1.769 0.000

Startup Voltage drop

UStartUp 4.146

Page 12: Installation calculation report

3.1.4 Circuit Motor Load 3 (2) (1)

Circuit breaker QA 3 (2) (1) Ib NA

Distance from origin NA Sizing Information Sized by system Range Compact NSX Designation NSX160F Circuit breaker rating 160 A Breaking capacity 36 kA TNS One pole breaking capacity NA IT One pole breaking capacity NA Reinforced breaking capacity NA Pole & protected pole 3P3d Trip unit designation MA Trip unit rating 100 A Long delay settings Ir 100 A Tr NA Short delay settings Isd current 1400 A Tsd NA Instantaneous tripping Ii current NA Discrimination Results

UpStream Discrimination Limit

Operating mode Normal

QA 0 NSX400F Micrologic 5.3 A 400 A / 4P4d

4800 A

Contactor LC1D115

Designation LC1D115

Type of coordination T1

Thermal relay LRD4367

Designation LRD4367

Ir 97

Cable WD 3 (2) (1) Parameters Length 10 m Max length 107 m Installation method 70

D1 Multi-core cable in conduit or in cable ducting in the ground

Type of cable Multi-core Nb of additional touching circuits 0 Insulation PVC Ground temperature 20 °C Level of third harmonic THDI 0 % Ib 97 A Sizing constraint Iz Sizing Information Sized with Ir Correction factors Temperature factor 1 Standard table reference B-52-15 Soil thermal resistivity factor 1 Standard table reference B-52-16 Loaded neutral factor 1 Standard table reference E-52-1

Page 13: Installation calculation report

Touching conductor factor 1 Standard table reference B-52-19 User correction factor 1 Overall factor 1

Selected phase Cross section area 1x50 mm² Core Copper Iz under real conditions 116 A Selected PE Cross section area 1x50 mm² Core Copper Short circuit current Ik3max Ik2max Ik1max Ik2min Ik1min Ief Ief2min Operating mode Normal (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Synthesis for all operating mode (kA) 5.96 5.16 0.00 3.51 0.00 3.86 0.00 Asynchronous LV Motor P4 Startup type Direct U 400 V Mechanical power 55 kW Startup current Id/Ir 7.2 Transient current I’’d/Ir <=19 Ir for sizing 97 A Sr for sizing 67.2 kVA Pr for sizing 57.8 kW

cos 0.86

Polarity 3Ph Number of circuit 1 Ku (mode Normal) 1 Harmonic generator No THDI3 0 % Sensitivity to over voltage NA Design current IL1 IL2 IL3 IN Operating mode Normal (A) 97.000 97.000 97.000 0 Synthesis for all operating mode (A) 97.000 97.000 97.000 0 Voltage drop Cumulated from upstream Circuit Operating mode Normal

U3L (%) 1.947 0.178

UL1L2 (%) 2.248 0.205

UL2L3 (%) 2.248 0.205

UL3L1 (%) 2.248 0.205

UL1N (%) 1.769 0.000

UL2N (%) 1.769 0.000

UL3N (%) 1.769 0.000

Startup Voltage drop

UStartUp 4.146

Operating mode Normal (kA) 5.96 5.16 5.11 3.68 3.59 4.25 0.00 Synthesis for all operating mode (kA) 5.96 5.16 5.11 3.68 3.59 4.25 0.00

Page 14: Installation calculation report

5

A

C

4

B

1

1 54

A

B

C

3'3

3'3

2988.9

2303.64

2332.8

SONDA

TOKZUESE 2.0m

TE RRUFEPRITESI

SHIRIT I ZINKUAR

Fe/Zn 20X3mm2

Shirit i ZinguarFe/Zn25x4mm²

Shirit i ZinguarFe/Zn25x4mm²

Shirit i ZinguarFe/Zn25x4mm²

Shiriti i salduar

per armature

cdo 2-3m

Shiriti i salduar

per armature

cdo 2-3m

Shiriti i salduar

per armature

cdo 2-3m

SONDA

TOKZUESE 2.0m

SONDA

TOKZUESE 2.0m

SONDA

TOKZUESE 2.0m

SONDA

TOKZUESE 2.0m

TE RRUFEPRITESI

SHIRIT I ZINKUAR

Fe/Zn 20X3mm2

TE RRUFEPRITESI

SHIRIT I ZINKUAR

Fe/Zn 20X3mm2

TE RRUFEPRITESI

SHIRIT I ZINKUAR

Fe/Zn 20X3mm2

TE RRUFEPRITESI

SHIRIT I ZINKUAR

Fe/Zn 20X3mm2

BAZA E THEMELEVE

Tokëzimi i rrufepritesit

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

STACIONI I POMPIMIT

Community Development

Initiatives

LIPIJAN

Page 15: Installation calculation report

20.00 %20.00 %

1410.00

450.00 400.0030.00

530.00

450.00 400.0030.00

1410.00

320.00

410.00

340.00

730.00

-0.50

-0.15-1.35

-1.35

-1.35

-1.35

-1.50

SHUKO PRIZA

IP

KM

&K

SH

P

KS

H O

KKK

BAZA E THEMELEVE

Instalimet Elektrike

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

Community Development

Initiatives

STACIONI I POMPIMIT

LIPIJAN

Page 16: Installation calculation report

KULMI

kulm i pjerrtë i=10%

s hori

zont

ale=

17.2

1 m

2

kulm i pjerrtë i=10%

s hori

zont

ale=

38.9

0 m

2

kulm i pjerrtë i=10%

s hori

zont

ale=

5.64

m2

2

2

3

3

A A

B B

1

1

Mbajtësi i shiritit

1 m

çdo

Mbajtësi i shiritit

Mbajtësi i shiritit

1 m

çdo

Mbajtësi i shiritit

Shirit i ZinguarFe/Zn20x3mm²

Shirit i ZinguarFe/Zn20x3mm²

Shirit i ZinguarFe/Zn20x3mm²

BAZA E THEMELEVE

Instalimi i rrufepritesit

FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

Community Development

Initiatives

STACIONI I POMPIMIT

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN

Page 17: Installation calculation report

FUQIA E NJEKOHESHME (kW) 154.8kWPnj

In=Pnj / (1.73*400) (A)

223.69 AIn

KUADRI MATES - KM dhe KUADRI SHPERNDARES I POMPAVE

26.0 26.0

KABLLO - PP00 (mm²) 4x25

lidhja matese

Cu 50

m

m

Fe-Z

n 25x4 m

m

400 A

KKK

tokëzimi ne themel

Nga rrjeti publik(TS)

KABLLO NËNTOKESORE

PP00 2x4x185mm²(Cu)+2x95 mm²

KUADRI KRYESORE KYQES- KKK

55.0

4x50

55.0

4x50

55.0

4x50

10

5x6

172.0 kWPins

4x25

KOADROT SHPRENDARESE

KKK dhe KM-SH

INSTALIME ELEKTRIKE

(Furnizmi i ipompave dhe objektit me

energji elektrike)FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

Community Development

Initiatives

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN

STACIONI I POMPIMIT

Page 18: Installation calculation report

FUQIA E NJEKOHESHME (kW)

KABLLO - PP00 (mm²)

FUQIA E INSTALUAR (kW)

( 5 X 6 )

7.50 kW

10.0 kW

Pi

Pnj

Pnj=Pi * k, k=0.75

INTENSITETI (A)- Pnj / (1.73*400)

10.83A

I

KUADRI SHPERNDARES O (Objekti)

BOJLER

FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

KOADROT SHPRENDARESE

KSH-O(Objekti)

Community Development

Initiatives

STACIONI I POMPIMIT

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN

Page 19: Installation calculation report

Residual - current protective devicesRCCB

RCCB

IV Përfshin pajisjet në furizim të përçuesve

III Përfshin tërë qarkun e lidhut sipas figurës

II Pajisjet që duhet të kyçën në mënyrë permanente përmes përçuesve

I Pajisjet të cilat kërkojn veçanarisht nivel të lartë të mbrojtjes

Kategoria e mbitensioneve (IEC 60664-1/VDE 0110 pjesa I) dhe niveli i tensionit impulsiv i durimit

Pajisjet

elektronike

(computer)

Pajisjet elektrike

I

1.5kV

II

2.5kV

III

4kV

D

6kV

Tensioni impuliv i

nivelit të durimit

Matësi i energjisë

CB

Shkarkuesi i

mbitensionit i

kategorisë

AC 400/230V

IV

Niveli i

mbitensioneve

Skema e mbrojtjes nga mbitensionet

LLOGARITJA E KABLLOVE FURNIZUESE

Ramjet e Tensionit

FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

Community Development

Initiatives

STACIONI I POMPIMIT

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN

Page 20: Installation calculation report

FAZA / PHASE

PROJEKTI / PROJECT

Data/Date

Përpjesa/Scale

1:50

PROJKETI KRYESOR

VENDI I NDËRTIMIT

LOCATION

PROJEKTUES

PROJECT DESIGN

INVESTITORI

INVESTOR

OBJEKTI

BUILDING

LLOGARITJA E KABLLOVE FURNIZUESE

Paisjet Elektrike

Community Development

Initiatives

STACIONI I POMPIMIT

INSTALIME ELEKTRIKE

(Furnizmi i pompave dhe objektit me

energji elektrike)

LIPIJAN