12/19/2014 Indian Standard: CODE OF PRACTICE FOR DESIGN LOADS (OTHER THAN EARTHQUAKE) FOR BUILDINGS AND STRUCTURES PART 5 S… https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 1/18 PREAMBLE (NOT PART OF THE STANDARD) In order to promote public education and public safety, equal justice for all, a better informed citizenry, the rule of law, world trade and world peace, this legal document is hereby made available on a noncommercial basis, as it is the right of all humans to know and speak the laws that govern them. END OF PREAMBLE (NOT PART OF THE STANDARD) IS : 875 (Part 5) 1987 (Reaffirmed 2008) Indian Standard CODE OF PRACTICE FOR DESIGN LOADS (OTHER THAN EARTHQUAKE) FOR BUILDINGS AND STRUCTURES PART 5 SPECIAL LOADS AND LOAD COMBINATIONS (Second Revision) Seventh Reprint JANUARY 2011 (Including Amendment No. 1) UDC 624.042 : 006.76 © Copyright 1988 BUREAU OF INDIAN STANDARDS MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002 Gr 5 July 1988 Indian Standard CODE OF PRACTICE FOR DESIGN LOADS (OTHER THAN EARTHQUAKE) FOR BUILDINGS AND STRUCTURES PART 5 SPECIAL LOADS AND LOAD COMBINATIONS (Second Revision) Structural Safety Sectional Committee, BDC 37 Chairman Representing Brig Dr L. V. Ramakrishna EngineerinChief’s Branch, Army Headquarters, New Delhi Members Dr K. G. Bhatia Bharat Heavy Electricals Limited, Corporate Research & Development Division, Hyderabad Shri M. S. Bhatia In personal capacity (A2/36, Safdarjang Enclave, New Delhi) Shri N. K. Bhattacharya EngineerinChief’s Branch, Army Headquarters, New Delhi Shri S. K. Malhotra (Alternate) i ii iii iv

Indian Standard_ CODE OF PRACTICE FOR DESIGN LOADS (OTHER THAN EARTHQUAKE) FOR BUILDINGS AND STRUCTURES PART 5 SPECIAL LOADS AND LOAD COMBINATIONS.pdf

Embed Size (px)

Citation preview

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 1/18

    PREAMBLE(NOTPARTOFTHESTANDARD)

    Inordertopromotepubliceducationandpublicsafety,equaljusticeforall,abetterinformedcitizenry,theruleoflaw,worldtradeandworldpeace,thislegaldocumentisherebymadeavailableonanoncommercialbasis,asitistherightofallhumanstoknowandspeakthelawsthatgovernthem.

    ENDOFPREAMBLE(NOTPARTOFTHESTANDARD)

    IS:875(Part5)1987

    (Reaffirmed2008)

    IndianStandardCODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5SPECIALLOADSANDLOADCOMBINATIONS

    (SecondRevision)

    SeventhReprintJANUARY2011(IncludingAmendmentNo.1)

    UDC624.042:006.76

    Copyright1988

    BUREAUOFINDIANSTANDARDSMANAKBHAVAN,9BAHADURSHAHZAFARMARG

    NEWDELHI110002

    Gr5

    July1988

    IndianStandardCODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGS

    ANDSTRUCTURES

    PART5SPECIALLOADSANDLOADCOMBINATIONS

    (SecondRevision)

    StructuralSafetySectionalCommittee,BDC37

    Chairman Representing

    BrigDrL.V.Ramakrishna EngineerinChiefsBranch,ArmyHeadquarters,NewDelhi

    Members

    DrK.G.Bhatia BharatHeavyElectricalsLimited,CorporateResearch&DevelopmentDivision,Hyderabad

    ShriM.S.Bhatia Inpersonalcapacity(A2/36,SafdarjangEnclave,NewDelhi)

    ShriN.K.Bhattacharya EngineerinChiefsBranch,ArmyHeadquarters,NewDelhi

    ShriS.K.Malhotra(Alternate)

    iiiiiiiv

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 2/18

    DrS.C.Chakrabarti CentralBuildingResearchInstitute(CSIR),Roorkee

    ShriA.Datta(Alternate)

    ChiefEngineer(NDZ)II CentralPublicWorksDepartment,NewDelhi

    SuperintendingSurveyorofWorks(NDZ)II(Alternate)

    DrP.Dayaratnam IndianInstituteofTechnology,Kanpur

    DrA.S.R.Sai(Alternate)

    DeputyMunicipalCommissioner(Engg)

    MunicipalCorporationofGreaterBombay,Bombay

    CityEngineer(Alternate)

    Director(CMDDI) CentralWaterCommission,NewDelhi

    DeputyDirector(CMDDI)(Alternate)

    MajGenA.M.Goglekar InstitutionofEngineers(India),Calcutta

    ProfD.N.Trikha(Alternate)

    Copyright1988

    BUREAUOFINDIANSTANDARDS

    ThispublicationisprotectedundertheIndianCopyrightAct(XIVof1957)andreproductioninwholeorinpartbyanymeansexceptwithwrittenpermissionofthepublishershallbedeemedtobeaninfringementofcopyrightunderthesaidAct.

    Members Representing

    ShriA.C.Gupta NationalThermalPowerCorporationLtd,NewDelhi

    ShriP.SenGupta StewartsandLloydsofIndiaLtd,Calcutta

    ShriM.M.Ghosh(Alternate)

    ShriG.B.Jahagirdar NationalIndustrialDevelopmentCorporationLtd,NewDelhi

    JointDirectorStandards(B&S),CB MinistryofRailways

    ShriS.P.Joshi TataConsultingEngineers,NewDelhi

    ShriA.P.Mull(Alternate)

    ShriS.R.Kulkarni M.N.Dastur&Co,Calcutta

    ShriS.N.Pal(Alternate)

    ShriH.N.Mishra ForestResearchInstituteandColleges,DehraDun

    ShriR.K.Punhani(Alternate)

    ShriT.K.D.Munshi EngineersIndiaLtd,NewDelhi

    DrC.Rajkumar NationalCouncilforCement&BuildingMaterials,NewDelhi

    DrM.N.KeshwaRao StructuralEngineeringResearchCentre(CSIR),Madras

    ShriM.V.Dharaneepathy(Alternate)

    ShriT.N.SubbaRao GammonIndiaLtd,Bombay

    DrS.V.Lonkar(Alternate)

    ShriP.K.Ray IndianEngineeringAssociation,Calcutta

    1

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 3/18

    ShriP.K.Mukherjee(Alternate)

    ShriS.Seetharaman MinistryofSurfaceTransport(RoadsWing),NewDelhi

    ShriS.P.Chakraborty(Alternate)

    ShriM.C.Sharma IndianMeteorologicalDepartment,NewDelhi

    ShriK.S.Srinivasan NationalBuildingsOrganization,NewDelhi

    ShriA.K.Lal(Alternate)

    ShriSushilKumar NationalBuildingConstructionCorporationLtd,NewDelhi

    ShriG.Raman,Director(CivEngg) DirectorGeneral,BIS(ExofficioMember)

    SecretaryShriB.R.Narayanappa

    DeputyDirector(CivEngg),BIS

    (continuedonpage18)

    IndianStandardCODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGS

    ANDSTRUCTURES

    PART5SPECIALLOADSANDLOADCOMBINATIONS

    (SecondRevision)

    0.FOREWORD

    0.1

    ThisIndianStandard(Part5)(SecondRevision)wasadoptedbytheBureauofIndianStandardson31August1987,afterthedraftfinalizedbytheStructuralSafetySectionalCommitteehadbeenapprovedbytheCivilEngineeringDivisionCouncil.

    0.2

    Abuildinghastoperformmanyfunctionssatisfacorily.Amongstthesefunctionsaretheutilityofthebuildingfortheintendeduseandoccupancy,structuralsafety,firesafetyandcompliancewithhygienic,sanitation,ventilationanddaylightstandards.Thedesignofthebuildingisdependentupontheminimumrequirementsprescribedforeachoftheabovefunctions.Theminimumrequirementspertainingtothestructuralsafetyofbuildingsarebeingcoveredinthiscodebywayoflayingdownminimumdesignloadswhichhavetobeassumedfordeadloads,imposedloads,snowloadsandotherexternalloads,thestructurewouldberequiredtobear.Strictconformitytoloadingstandardsrecommendedinthiscode,itishoped,willnotonlyensurethestructuralsafetyofthebuildingswhicharebeingdesignedandconstructedinthecountryandtherebyreducethehazardstolifeandpropertycausedbyunsafestructures,butalsoeliminatethewastagecausedbyassumingunnecessarilyheavyloadings.Notwithstandingwhatisstatedregardingthestructuralsafetyofbuildings,theapplicationoftheprovisionsshouldbecarriedoutbycompetentandresponsiblestructuraldesignerwhowouldsatisfyhimselfthatthestructuredesignedinaccordancewiththiscodemeetsthedesiredperformancerequirementswhenthesameiscarriedoutaccordingtospecifications.

    0.3

    Thisstandardcodeofpracticewasfirstpublishedin1957fortheguidanceofcivilengineers,

    2

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 4/18

    designersandarchitectsassociatedwithplanninganddesignofbuildings.Itincludedtheprovisionsforbasicdesign

    loads(deadloads,liveloadswindloadsandseismicloads)tobeassumedinthedesignofbuildings.Initsfirstrevisionin1964,thewindpressureprovisionsweremodifiedonthebasisofstudiesofwindphenomenonanditseffectsonstructures,undertakenbythespecialcommitteeinconsultationwiththeIndianMeteorologicalDepartment.Inadditiontothis,newclausesonwindloadsforbutterflytypestructureswereincludedwindpressurecoefficientsforsheetedroofsbothcurvedandslopingweremodifiedseismicloadprovisionsweredeleted(separatecodehavingbeenprepared)andmetricsystemofweightsandmeasurementswasadopted.

    0.3.1

    Withtheincreasedadoptionofthecode,anumberofcommentswerereceivedontheprovisionsonliveloadvaluesadoptedfordifferentoccupancies.SimultaneouslyliveloadsurveyshavebeencarriedoutinAmerica,Canadaandothercountriestoarriveatrealisticliveloadsbasedonactualdeterminationofloading(movableandimmovable)indifferentoccupancies.Keepingthisinviewandotherdevelopmentsinthefieldofwindengineering,thecommitteeresponsibleforthepreparationofthestandarddecidedtopreparesecondrevisioninthefollowingfiveparts:

    Part1Deadloads

    Part2Imposedloads

    Part3Windloads

    Part4Snowloads

    Part5Specialloadsandloadcombinations.

    Earthquakeloadiscoveredinaseparatestandard,namelyIS:18931984*whichshouldbeconsideredalongwiththeaboveloads.

    0.3.2

    Thiscode(Part5)dealswithloadsandloadeffects(otherthanthosecoveredinParts1to4,andseismicloads)duetotemperaturechanges,internallygeneratingstresses(duetocreep,shrinkage,differentialsettlement,etc)inthebuildinganditscomponents,soilandhydrostaticpressure,accidentalloads,etc.Thispartalsoincludesguidance,onloadcombinations.

    *Criteriaforearthquakeresistantdesignofstructures(thirdrevision).

    0.4

    ThecodehastakenintoaccounttheprevailingpracticesinregardtoloadingstandardsfollowedinthiscountrybythevariousmunicipalauthoritiesandhasalsotakennoteofthedevelopmentsinanumberofcountriesabroadInthepreparationofthiscode,thefollowing,nationalstandardshavebeenexamined:

    a. NationalBuildingCodeofCanada(1977)SupplementNo:4.CanadianStructuralDesignManual.

    b. DS4101983Codeofpracticeforloadsforthedesignofstructures.DanishStandardsInstitution.

    c. NZS42031976NewZealandStandardGeneralstructuraldesignanddesignloadingforbuilding.StandardsAssociationofNewZealand.

    3

    4

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 5/18

    d. ANSIA58.11982AmericanStandardBuildingcoderequirementsforminimumdesignloadsinbuildingsandotherstructures.

    1.SCOPE

    1.1

    Thiscode(Part5)dealswithloadsandloadeffectsduetotemperaturechanges,soilandhydrostaticpressures,internallygeneratingstresses,(duetocreep,shrinkage,differentialsettlement,etc),accidentalloadsetc,tobeconsideredinthedesignofbuildingsasappropriate.Thispartalsoincludesguidanceonloadcombinations.Thenatureofloadstobeconsideredforaparticularsituationistobebasedonengineeringjudgement.

    2.TEMPERATUREEFFECTS

    2.1

    Expansionandcontractionduetochangesintemperatureofthematerialsofastructureshallbeconsideredindesign.Provisionshallbemadeeithertorelievethestressbyprovisionofexpansion/contractionjointsinaccordancewithIS:34141968*ordesignthestructuretocarryadditionalstressesduetotemperatureeffectsasappropriatetotheproblem.

    2.1.1

    Thetemperaturerangevariesfordifferentregionsandunderdifferentdiurnalandseasonalconditions.TheabsolutemaximumandminimumtemperaturewhichmaybeexpectedindifferentlocalitiesinthecountryareindicatedinFig.1and2respectively.Thesefiguresmaybeusedforguidanceinassessingthemaximumvariationsoftemperature.

    2.1.2

    ThetemperaturesindicatedinFig.1and2aretheairtemperaturesintheshade.Therangeofvariationintemperatureofthebuildingmaterialsmaybeappreciablygreaterorlessthanthevariationofairtemperatureandisinfluencedbytheconditionofexposureandtherateatwhichthematerialscomposingthestructureabsorborradiateheat.Thisdifferenceintemperaturevariationsofthematerialandairshouldbegivendueconsideration.

    2.1.3

    Thestructuralanalysismusttakeintoaccount:(a)changesofthemean(throughthesection)temperatureinrelationtotheinitialtemperature(st),and(b)thetemperaturegradientthroughthesection.

    *Codeofpracticefordesignandinstallationofjointsinbuildings.

    5

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 6/18

    Fig.1ChartShowingHighestMaximumTemperature

    6

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 7/18

    Fig.2ChartShowingLowestMinimumTemperature

    2.1.3.1

    Itshouldbeborneinmindthatthechangesofmeantemperatureinrelationtotheinitialareliabletodifferasbetweenonestructuralelementandanotherinbuildingsorstructures,asforexample,betweentheexternalwallsandtheinternalelementsofabuilding.Thedistributionoftemperaturethroughsectionofsingleleafstructuralelementsmaybeassumedlinearforthepurposeofanalysis.

    7

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 8/18

    2.1.3.2

    Theeffectofmeantemperaturechangest1,andt2,andthetemperaturegradientsv1andv2in

    thehotandcoldseasonsforsingleleafstructuralelementsshallbeevaluatedonthebasisofanalyticalprinciples.

    Note1Forportionsofthestructurebelowgroundlevel,thevariationoftemperatureisgenerallyinsignificant.However,duringtheperiodofconstructionwhentheportionsofthestructureareexposedtoweatherelements,adequateprovisionshouldbemadetoencounteradverseeffects,ifany.

    Note2Ifitcanbeshownbyengineeringprinciples,orifitisknownfromexperience,thatneglectofsomeoralltheeffectsoftemperaturedonotaffectthestructuralsafetyandserviceability,theyneednotbeconsideredindesign,

    3.HYDROSTATICANDSOILPRESSURE

    3.1

    Inthedesignofstructuresorpartsofstructuresbelowgroundlevel,suchasretainingwallsandotherwallsinbasementfloors,thepressureexertedbysoilorwaterorbothshallbedulyaccountedforonthebasisofestablishedtheories.Dueallowanceshallbemadeforpossiblesurchargefromstationaryormovingloads.Whenaportionorwholeofthesoilisbelowthefreewatersurface,thelateralearthpressureshallbeevaluatedforweightofsoildiminishedbybuoyancyandthefullhydrostaticpressure.

    3.1.1

    Allfoundationslabsandotherfootingssubjectedtowaterpressureshallbedesignedtoresistauniformlydistributedupliftequaltothefullhydrostaticpressure.Checkingofoverturningoffoundationundersubmergedconditionshallbedoneconsideringbuoyantweightoffoundation.

    3.2

    Whiledeterminingthelateralsoilpressureoncolumnlikestructuralmembers,suchaspillarswhichrestinslopingsoils,thewidthofthemembershallbetakenasfollows(seeFig.3):

    ActualWidthofMember RatioofEffectiveWidthtoActualWidth

    Lessthan05m 30

    Beyond05mandupto1m 30to20

    Beyond1m 20

    Therelievingpressureofsoilinfrontofthestructuralmemberconcernedmaygenerallynotbetakenintoaccount.

    8

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 9/18

    Fig.3SketchShowingEffectiveWidthOfPillarForCalculatingSoilPressure

    3.3

    Safeguardingofstructuresandstructuralmembersagainstoverturningandhorizontalslidingshallbeverified.Imposedloadshavingfavourableeffectshallbedisregardedforthepurpose.Dueconsiderationshallbegiventothepossibilityofsoilbeingpermanentlyortemporarilyremoved.

    4.FATIGUE

    4.1

    GeneralFatiguecracksareusuallyinitiatedatpointsofhighstressconcentration.Thesestressconcentrationsmaybecausedbyorassociatedwithholes(suchasboltorrivetholesinsteelstructures),weldsincludingstrayorfusionsinsteelstructures,defectsinmaterials,andlocalandgeneralchangesingeometryofmembers.Thecracksusuallypropagateiftheloadingiscyclicandrepetitive.

    Wherethereissuchcyclicandrepetitiveloading,suddenchangesofshapeofamemberorpartofamember,speciallyinregionsoftensilestressand/orlocalsecondarybending,shallbeavoided.Suitablestepsshallbetakentoavoidcriticalvibrationsduetowindandothercauses

    4.2

    Wherenecessary,permissiblestressesshallbereducedtoallowfortheeffectsoffatigue.Allowanceforfatigueshallbemadeforcombinationsofstressesduetodeadloadandimposedload.Stressesduetowindandearthquakesmaybeignoredwhenfatigueisbeingconsideredunlessotherwisespecifiedintherelevantcodesofpractice.

    Eachelementofthestructureshallbedesignedforthenumberofstresscyclesofeachmagnitudetowhichitisestimatedthattheelementisliabletobesubjectedduringtheexpectedlifeofthestructure.Thenumberofcyclesofeachmagnitudeshallbeestimatedinthelightofavailabledataregardingtheprobablefrequencyofoccurrenceofeachtypeofloading.

    9

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 10/18

    NoteApartfromthegeneralobservationsmadehereinthecodeisunabletoprovideanypreciseguidanceinestimatingtheprobablisticbehaviourandresponseofstructuresofvarioustypesarisingoutofrepetitiveloadingapproachingfatigueconditionsinstructuralmembers,joints,materials,etc.

    5.STRUCTURALSAFETYDURINGCONSTRUCTION

    5.1

    Allloadsrequiredtobecarriedbythestructuresoranypartofitduetostorageorpositioningofconstructionmaterialsanderectionequipmentincludingallloadsduetooperationofsuchequipment,shallbeconsideredaserectionloads.Properprovisionshallbemade,includingtemporarybracingstotakecareofallstressesduetoerectionloads.Thestructureasawholeandallpartsofstructureinconjunctionwiththetemporarybracingsshallbecapableofsustainingtheseerectionloadswithoutexceedingthepermissiblestressesspecifiedinrespectivecodesofpractice.Deadload,windloadandsuchpartsofimposedloadaswouldbeimposedonthestructureduringtheperiodoferectionshallbetakenasactingtogetherwitherectionloads.

    6.ACCIDENTALLOADS

    6.0

    GeneralTheoccurrenceofaccidentalloadswithasignificantvalue,isunlikelyonagivenstructureovertheperiodoftimeunderconsideration,andalsoinmostcasesisofshortduration.Theoccurrenceofanaccidentalloadcouldinmanycasesbeexpectedtocausesevereconsequencesunlessspecialmeasuresaretaken:

    Theaccidentalloadsarisingoutofhumanactionincludethefollowing:

    a. Impactsandcollisions,

    b. Explosions,and

    c. Fire.

    Characteristicoftheabovestatedloadsarethattheyarenotaconsequenceofnormaluseandthattheyareundesired,andthatextensiveeffortsaremadetoavoidthem.Asaresult,theprobabilityofoccurrenceofanaccidentalloadissmallwhereastheconsequencesmaybesevere.

    Thecausesofaccidentalloadsmaybe:

    a. inadequatesafetyofequipment(duetopoordesignorpoormaintenance)and

    b. wrongoperation(duetoinsufficientteachingortraining,indisposition,negligenceorunfavourableexternalcircumstances).

    Inmostcases,accidentalloadsonlydevelopunderacombinationofseveralunfavourableoccurrence.Inpracticalapplications,itmaybenecessarytoneglectthemostunlikelyloads.Theprobabilityofoccurrenceofaccidentalloadswhichareneglectedmaydifferfordifferentconsequencesofapossiblefailure.Adatabaseforadetailedcalculationoftheprobabilitywillseldombeavailable.

    NoteDeterminationofAccidentalLoadsTypesandmagnitudeofaccidentalloadsshouldpreferablybebasedonariskanalysis.Theanalysisshouldconsiderallfactorsinfluencingthemagnitudeoftheaction,includingpreventivemeasuresforaccidental

    10

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 11/18

    situations.Generally,onlytheprincipalloadbearingsystemneedbedesignedforrelevantultimatelimitstates.

    6.1ImpactsandCollisions

    6.1.1

    GeneralDuringanimpact,thekineticimpactenergyhastobeabsorbedbythevehiclehittingthestructureandbythestructureitself.Inanaccurateanalysis,theprobabilityofoccurrenceofanimpactwithacertainenergyandthedeformationcharacteristicsoftheobjecthittingthestructureandthestructureitselfattheactualplacemustbeconsidered.Impactenergiesfordroppedobjectsshouldbebasedontheactualloadingcapacityandliftingheight.

    Commonsourcesofimpactare:

    a. vehicles

    b. droppedobjectsfromcranes,forklifts,etc

    c. cranesoutofcontrol,cranefailuresand

    d. flyingfragments.

    Thecodalrequirementsregardingimpactfromvehiclesandcranesaregivenin6.1.2and6.1.3.

    6.1.2

    CollisionsBetweenVehiclesandStructuralElementsInroadtraffic,therequirementthatastructureshallbeabletoresistcollisionmaybeassumedtobefulfilledifitisdemonstratedthatthestructuralelementisabletostopafictitiousvehicle,asdescribedinthefollowing.Itisassumedthatthevehiclestrikesthestructuralelementatheightof12minanypossibledirectionandataspeedof10m/s(36km/h).

    Thefictitiousvehicleshallbeconsideredtoconsistoftwomassesm1andm2whichduring

    compressionofthevehicleproduceanimpactforceincreasinguniformlyfromzero,correspondingtotherigiditiesC1andC2.Itisassumedthatthemassm1isbreakedcompletelybeforethebrakingofmass

    m2begins.

    Thefollowingnumericalvaluesshouldbeused:

    m1=400kg,C1=10000kNpermthevehicleiscompressed.

    m2=12000kg,C2=300kNpermthevehicleiscompressed.

    NoteThedescribedfictitiouscollisioncorrespondsinthecaseofanonelasticstructuralelementtoamaximumstaticforceof630kNforthemassm1and600kNfor

    themassm2irrespectiveoftheelasticity.Itwill,therefore,beonthesafesidetoassume

    thestaticforcetobe630kN.

    Inaddition,brakingofthemassm1willresultinanimpactwave,theeffectofwhichwilldepend

    toagreatextentonthekindofstructuralelementconcerned.Consequently,itwillnotalwaysbesufficienttodesignforthestaticforce.

    6.1.3

    11

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 12/18

    SafetyRailingsWithregardtosafetyrailingsputuptoprotectstructuresagainstcollisionduetoroadtraffic,itshouldbeshownthattherailingsareabletoresistonimpactasdescribedin6.1.2.

    NoteWhenavehiclecollideswithsafetyrailings,thekineticenergyofthevehiclewillbeabsorbedinpartbythedeformationoftherailingsand,inpartbythedeformationofthevehicle.Thepartofthekineticenergywhichtherailingsshouldbeabletoabsorbwithoutbreakingdownmaybedeterminedonthebasisoftheassumedrigidityofthevehicleduringthecompression.

    6.1.4

    CraneImpactLoadonBufferStopThebasichorizontalloadPy(tonnes),actingalongthe

    cranetrackproducedbyimpactofthecraneonthebufferstop,iscalculatedbythefollowingformula:

    Py=MV2/F

    where

    V = speedatwhichthecraneistravellingatthemomentofimpact(assumedequaltohalfthenominalvalue)(m/s)

    F = maximumshorteningofthebuffer,assumedequalto01mforlightduty,mediumdutyandheavydutycraneswithflexibleloadsuspensionandloadingcapacitynotexceeding50t,and02mineveryothercranesand

    M = thereducedcranemass(t.s2/m)andisobtainedbytheformula:

    where

    g = accelerationduetogravity(981m/s2)

    Ph = cranebridgeweight(t)

    Pt = crabweight(t)

    k = acoefficient,assumedequaltozeroforcraneswithflexibleloadsuspensionandequaltooneforcraneswithrigidsuspension

    Q = craneloadingcapacity(t)

    Lk = cranespan(m)and

    l = nearnessofcrab(m).

    6.2Explosions

    6.2.1

    GeneralExplosionsmaycauseimpulsiveloadingonastructure.Thefollowingtypesofexplosionsareparticularlyrelevant:

    a. Internalgasexplosionswhichmaybecausedbyleakageofgaspiping(includingpipingoutsidetheroom),evaporationfromvolatileliquidsorunintentionalevaporationfromsurfacematerial(forexample,fire)

    12

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 13/18

    b. Internaldustexplosions

    c. Boilerfailure

    d. Externalgascloudexplosionsand

    e. Externalexplosionsofhighexplosives(TNT,dynamite).

    Thecodalrequirementregardinginternalgasexplosionsisgivenin6.2.2.

    6.2.2

    ExplosionEffectinClosedRoomsGasexplosionmaybecaused,forexample,byleaksingaspipes(inclusiveofpipesoutsidetheroom),evaporationfromvolatileliquidsorunintentionalevaporationofgasfromwallsheathings(forexample,causedbyfire).

    Note1Theeffectofexplosionsdependsontheexplodingmedium,theconcentrationoftheexplosion,theshapeoftheroom,possibilitiesofventilationoftheexplosion,andtheductilityanddynamicpropertiesofthestructure.Inroomswithlittlepossibilityforreliefofthepressurefromtheexplosion,verylargepressuresmayoccur.

    Internaloverpressurefromaninternalgasexplosioninroomsofsizescomparabletoresidentialroomsandwithventilationareasconsistingofwindowglassbreakingata

    pressureof4kN/m2(34mmmachinemadeglass)maybecalculatedfromthefollowingmethod:

    a. TheoverpressureisassumedtodependonafactorA/V,whereAisthetotalwindow

    areainm2,Visthevolumeinm2oftheroomconsidered.

    b. Theinternalpressureisassumedtoactsimultaneouslyuponallwallsandfloorsinoneclosedroom.

    c. Theactionqomaybetakenasstaticaction.

    Ifaccountistakenofthetimecurveofaction,thefollowing(Fig.4)schematiccorrespondencebetweenpressureandtimeisassumed,wheret1isthetimefromthestart

    ofcombustionuntilmaximumpressureisreached,andt2isthetimefrommaximum

    pressuretotheendofcombustion.Fort1andt2,themostunfavourablevaluesshouldbe

    choseninrelationtothedynamicpropertiesofthestructures.However,thevaluesshouldbechosenwithintheintervalsasgiveninFig.5.

    Note2Figure4isbasedontestswithgasexplosionsinroomcorrespondingtoordinaryresidentialflatsandshould,therefore,notbeappliedtoconsiderablydifferentconditions.Thefigurecorrespondstoanexplosioncausedbytowngasanditmighttherefore,besomewhatonthesafesideinroomswherethereisonlythepossibilityofgaseswithalowerrateofcombustion.

    Thepressuremaybeappliedsolelyinoneroomorinmoreroomsatthesametime.Inthelattercase,allroomsareincorporatedinthevolumeV.Onlywindowsorothersimilarlyweakandlightweightstructuralelementsmaybetakentobeventilationareaseventhroughcertainlimitedstructuralpartsbreakatpressureslessthanqo.

    Figure4isgivenpurelyasguideandprobabilityofoccurrenceofanexplosionshouldbecheckedineachcaseusingappropriatevalues.

    13

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 14/18

    6.3VerticalLoadonAirRaidShelters

    6.3.1

    CharacteristicValuesAsregardsbuildingsinwhichtheindividualfloorsareacteduponbya

    totalcharacteristicimposedactionofupto50kN/m2,verticalactionsonairraidsheltersgenerallylocatedbelowgroundlevel,forexample,basement,etc,shouldbeconsideredtohavethefollowingcharacteristicvalues:

    a) Buildingswithupto2storeys 28kN/m2

    b) Buildingswith3to4storeys 34kN/m2

    c) Buildingswithmorethan4storeys 41kN/m2

    d) Buildingsofparticularlystableconstructionirrespectiveofthenumberofstoreys 28kN/m2

    Inthecaseofbuildingswithfloorsthatareacteduponbyacharacteristicimposedactionlarger

    than50kN/m2,theabovevaluesshouldbeincreasedbythedifferencebetweentheaverageimposed

    actiononallstoreysabovetheoneconcernedand50kN/m2.

    Note1Bystoreysitisunderstood,everyutilizablestoreyabovetheshelter.

    Note2Bybuildingsofaparticularstableconstructionitisunderstood,buildingsinwhichtheloadbearingstructuresaremadefromreinforcedinsituconcrete.

    Fig.4SketchShowingRelationBetweenPressureandTime

    Fig.5SketchShowingTimeIntervalAndPressure

    6.4Fire

    14

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 15/18

    6.4.1

    GeneralPossibleextraordinaryloadsduringafiremaybeconsideredasaccidentalactions.Examplesareloadsfrompeoplealongescaperoutesandloadsonanotherstructurefromstructurefailingbecauseofafire.

    6.4.2

    ThermalEffectDuringFireThethermaleffectduringfiremaybedeterminedfromoneofthefollowingmethods:

    a. Timetemperaturecurveandtherequiredfireresistance(minutes),or

    b. Energybalancemethod.

    Ifthethermaleffectduringfireisdeterminedfromenergybalancemethod,thefireloadistakentobe:

    q=12tb

    where

    q = fireaction(KJperm2floor),and

    tb = requiredfireresistance(minutes)(seeIS:16421960*).

    NoteThefireactionisdefinedasthetotalquantityofheatproducedbycompletecombustionofallcombustiblematerialinthefirecompartment,inclusiveofstoredgoodsandequipmenttogetherwithbuildingstructuresandbuildingmaterials.

    7.OTHERLOADS

    7.1

    Otherloadsnotincludedinthepresentcodesuchasspecialloadsduetotechnicalprocess,moistureandshrinkageeffects,etc,shouldbetakenintoaccountwherestipulatedbybuildingdesigncodesorestablishedinaccordancewiththeperformancerequirementofthestructure.

    8.LOADCOMBINATIONS

    8.0

    GeneralAjudiciouscombinationoftheloads(specifiedinParts1to4ofthisstandardandearthquake),keepinginviewtheprobabilityof:

    a. theiractingtogether,and

    b. theirdispositioninrelationtootherloadsandseverityofstressesordeformationscausedbycombinationsofthevariousloadsisnecessarytoensuretherequiredsafetyandeconomyinthedesignofastructure.

    *Codeofpracticeforsafetyofbuildings(general):Materialsanddetailsofconstruction.

    15

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 16/18

    8.1

    LoadCombinationsKeepingtheaspectspecifiedin8.0,thevariousloadsshould,therefore,becombinedinaccordancewiththestipulationsintherelevantdesigncodes.Intheabsenceofsuchrecommendations,thefollowingloadingcombinations,whichevercombinationproducesthemostunfavourableeffectinthebuilding,foundationorstructuralmemberconcernedmaybeadopted(asageneralguidance).Itshouldalsoberecognizedinloadcombinationsthatthesimultaneousoccurrenceofmaximumvaluesofwind,earthquake,imposedandsnowloadsisnotlikely.

    a. DL

    b. DL+IL

    c. DL+WL

    d. DL+EL

    e. DL+TL

    f. DL+IL+WL

    g. DL+IL+EL

    h. DL+IL+TL

    i. DL+WL+TL

    j. DL+EL+TL

    k. DL+IL+WL+TL

    l. DL+IL+EL+TL

    (DL=deadload,IL=imposedload,WL=windload,EL=earthquakeload,TL=temperatureload).

    Note1Whensnowloadispresentonroofs,replaceimposedloadbysnowloadforthepurposeofaboveloadcombinations.

    Note2Therelevantdesigncodesshallbefollowedforpermissiblestresseswhenthestructureisdesignedbyworkingstressmethodandforpartialsafetyfactorswhenthestructureisdesignedbylimitstatedesignmethodforeachoftheaboveloadcombinations.

    Note3Wheneverimposedload(IL)iscombinedwithearthquakeload(EL),theappropriatepartofimposedloadasspecifiedinIS:1893J984*shouldbeusedbothforevaluatingearthquakeeffectandforcombinedloadeffectsusedinsuchcombination.

    Note4Forthepurposeofstabilityofthestructureasawholeagainstoverturning,therestoringmomentshallbenotlessthan12timesthemaximumoverturningmomentduetodeadloadplus14timesthemaximumoverturningmomentduetoimposedloads,Incaseswheredeadloadprovidestherestoringmoment,only09timesthedeadloadshallbeconsidered.Therestoringmomentsduetoimposedloadsshallbeignored.Incaseofhighwatertable,theeffectsofbuoyancyhavetobesuitablytakenintoconsideration.

    Note5Incaseofhighwatertable,thefactorofsafetyof1.2againstupliftaloneshallbeprovided.

    Note6Thestructureshallhaveafactoragainstslidingofnotlessthan14underthemostadversecombinationoftheappliedloads/forces.Inthiscase,only09timesthedeadloadshallbetakenintoaccount.

    Note7Wherethebearingpressureonsoilduetowindaloneislessthan25percentofthatduetodeadloadandimposedload,itmaybeneglectedindesign.Wherethis

    16

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 17/18

    exceeds25percentfoundationmaybesoproportionedthatthepressureduetocombinedeffectofdeadload,imposedloadandwindloaddoesnotexceedtheallowablebearingpressurebymorethan25percent.Whenearthquakeeffectisincluded,thepermissibleincreaseisallowablebearingpressureinthesoilshallbeinaccordancewithIS:18931984*.

    Reducedimposedload(IL)specifiedinPart2ofthisstandardforthedesignofsupportingstructuresshouldnotbeappliedincombinationwithearthquakeforces.

    Note8Otherloadsandaccidentalloadcombinationsnotincludedshouldbedealtwithappropriately.

    Note9Craneloadcombinationsarecoveredunder/Part2ofthisstandard(see6.4ofPart2ofthisstandard).

    *Criteriaforearthquakeresistantdesignofstructures(fourthrevision).

    (Continuedfrompage2)

    PanelonLoads(OtherthanWindLoads),BDC37:P3

    Convener Representing

    ShriT.N.SubbaRao GammonIndiaLimited,Bombay

    DrS.V.Lonkar(Alternate)

    Members

    ShriS.R.Kulkarni M.N.Dastur&CoLtd,Calcutta

    ShriM.L.Mehta Metallurgical&EngineeringConsultants(India)Ltd,Ranchi

    ShriS.K.Datta(Alternate)

    ShriT.V.S.R.AppaRao StructuralEngineeringResearchCentre,CSIRCampus,Madras

    ShriNageshR.Iyer(Alternate)

    ShriC.N.Srinivasan C.R.NarayanaRao,Madras

    SuperintendingEngineer(D) CentralPublicWorksDepartment(CentralDesignsOrganization),NewDelhi

    ExecutiveEngineer(D)VII(Alternate)

    DrH.C.Visvesvaraya NationalCouncilforCementandBuildingMaterials,NewDelhi

    BUREAUOFINDIANSTANDARDS

    Headquarters:

    ManakBhavan,9BahadurShahZafarMarg,NEWDELH1110002

    Telephones:23230131,23233375,23239402 Fax:+911123239399,23239382

    Email:[email protected] Website:http://www.bis.org.in

    CentralLaboratory: Telephone

    PlotNo.20/9,SiteIV,SahibabadIndustrialArea,SAHIBABAD201010 01204177100

    TrainingInstitute:

    PlotNo.A2021,IndustrialArea,Sector62,GautamBudhNagar,Noida201307 01202402204

    RegionalOffices:

    Central:ManakBhavan,9BahadurShahZafarMarg,NEWDELH1110002 01123237617

    17

    1819

  • 12/19/2014 IndianStandard:CODEOFPRACTICEFORDESIGNLOADS(OTHERTHANEARTHQUAKE)FORBUILDINGSANDSTRUCTURESPART5S

    https://law.resource.org/pub/in/bis/S03/is.875.5.1987.html 18/18

    *Eastern:1/14CITSchemeVIIM,V.I.P.Road,Kankurgachi,KOLKATA700054 03323208499

    Northern:SCO335336,Sector34A,CHANDIGARH160022 01722609285

    Southern:C.I.T.Campus,IVCrossRoad,CHENNAI600113 04422541984

    Western:Manakalaya,E9,MIDC,BehindMarolTelephoneExchange,Andheri(East),MUMBAI400093

    0222832929528327858

    BranchOffices:

    Pushpak,NurmohamedShaikhMarg,KhanpurMAHMEDABAD380001 07925601348

    PeenyaIndustrialArea,1stStage,BangaloreTumkurRoad,BANGALORE560058 08028394955

    CommercialcumofficeComplex,Manakalaya,Opp.DusheraMaidan,E5,AreraColony,BittanMarket,BHOPAL462016

    07552423449

    62/63,GangaNagar,UnitVI,BHUBANESHWAR751001 06742393627

    5thFloor,KovaiTowers,44BalaSundaramRoad,COIMBATORE641018 04222240141

    C43,Sector1,DefenceColony,DEHRADUN248001 01352665272

    SCO21,Sector12,FARIDABAD121007 01292292175

    SavitriComplex,116G.T.Road,GHAZIABAD201001 01202861498

    53/5WardNo.29,R.G.BaruaRoad,5thBylane,ApurbaSinhaPath,GUWAHATI

    781003

    03612456508

    M4Block,ManoranjanComplex,M.J.Road,HAYDERABAD500001 04024731082

    PrithaviRajRoad,OppositeBharatOverseasBank,CScheme,JAIPUR302001 01412223282

    11/418BSarvodayaNagar,KANPUR208005 05122233012

    SethiBhavan,2ndFloor,BehindLeelaCinema,NavalKishoreRoad,LUCKNOW226001 05222618923

    N.I.T,Building,SecondFloor,GokulpatMarket,NAGPUR440010 07122554268

    H.No.15,Sector3,PARWANOO,Distt.Solan(HP)173220 0792235437

    PatliputraIndustrialEstate,PATNA800013 06122262808

    PlotNo.657660,MarketYard,Gultekdi,PUNE411037 02024274804

    NSICTechnicalServiceCenter,1stFloor,Admn.Building,BhavnagarRoad,80ftRoad