www.white-rodgers.com 49 APPLIANCE APPLIANCE GAS WATER HEATER CONTROLS 150 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 Model(s) Page(s) Flush Mount Fan/Limit/Attic Fan Control ................................................................................................................................... 52 ELECTRIC WATER HEATER THERMOSTATS 151 INDEX GAS DRYER VALVES 153 Model(s) Page(s) 25M Gas Valves and Coils ........................................................................................................................................................... 53

INDEX APPLIANCE - Air Filters, Furnace Filters, Electronic Air

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

www.white-rodgers.com �49

AP

PL

IAN

CE

APPLIANCE

GAS WATER HEATER CONTROLS 150

SNAP DISC CONTROLS/LIMITS/SWITCHES 152

Model(s) Page(s)

Flush Mount Fan/Limit/Attic Fan Control ................................................................................................................................... �52

ELECTRIC WATER HEATER THERMOSTATS 151

INDEX

GAS DRYER VALVES 153

Model(s) Page(s)

25M Gas Valves and Coils ........................................................................................................................................................... �53

www.white-rodgers.com�50

AP

PL

IAN

CE

SPECIFICATIONSInlet Size. . . . . . . . . . . . . . . . . . . . . . . . . . �/2” NPTOutlet Size . . . . . . . . . . . . . . . . . . . . . . . . �/2” inverted flareOutlet Adapter Fittings . . . . . . . . . . . . . . . �/2” inverted flare x 3/8” NPT reducer(furnished with controls noted below) adapter. �/2” x �/2” inverted flare outlet extension adapter (F26-002�)Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . 3/4” NPT, ��/4” shank length, 4�/2” bulb insertion lengthPilot Connection . . . . . . . . . . . . . . . . . . . . �/4” compression fittingAgency . . . . . . . . . . . . . . . . . . . . . . . . . . . A.G.A. certified

Model Pressure Regulation Temperature Shank Number Main Burner Pilot Range Length

37C73U-168 ➀ 3.5” W.C. (A.O. Smith Style) Fixed 70 to �60°F (2� to 7�°C) ��/4”

GAS WATER HEATER CONTROLSFor Replacement of Standard Gas Water Heater Controls WithBuilt-In E.C.O. (Energy Cut Off)

FEATURES• Automatic shut-off of main and pilot gas in the event of pilot failure.• Pilot gas cock with safe lighting feature and filter.• Temperature adjustment.• Manifold pressure tap.• Built-In E.C.O. (Energy Cut Off) non-cycling high limit.

For use with Natural Gas (Right Hand Threads on Outlet)

Model Pressure Regulation Temperature Shank Number Main Burner Pilot Range Length

37C72U-185 ➁ �0.0” W.C. Fixed 70 to �60°F (2� to 7�°C) ��/4”

For use with LP Gas (Left Hand Threads)

➁ Includes Left Hand outlet extension fittings: �/2” LH x �/2” LH inverted flare (F26-0160) and �/2” LH x 3/8” LH inverted flare (F26-0161)

➀ Outlet adapter fittings included.

37C73U-168

GAS WATER HEATERCONTROLS

www.white-rodgers.com �5�

AP

PL

IAN

CE

ELECTRIC WATERHEATER THERMOSTATS

UNIVERSAL REPLACEMENTS FOR ELECTRICWATER HEATER THERMOSTATS AND LIMITSSurface Mount Temperature Sensing ControlsFEATURES• High electrical capacity.• Snap-Action contact.• Long life-proven reliability.• Adjustable control or manual reset styles.

SPECIFICATIONSAgency . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. and C.S.A. recognized

A.C. Electrical Ratings Model Switch (Non-Inductive) Number Description Action Range 120/240 VAC 277 VAC 480 VAC 754-1 DPST limit (manual reset) Open on Rise 170°F fixed (77°C) – 40.0A 25.0A 755-1 SPST thermostat Open on Rise 90 to �50°F(32 to 66°C) 30.0A 25.0A �2.5A 755-50 754-� + 755-� – – 30.0A 25.0A �2.5A 756-1 SPDT thermostat Open �-2 on Rise 90 to �50°F(32 to 66°C) 30.0A 25.0A �2.5A 756-50 754-� + 756-� – – 30.0A 25.0A �2.5A 756-2 SPDT thermostat Open �-2 on Rise 90 to �70°F(32 to 77°C) 30.0A 25.0A �2.5A

754-1

755-1

755-50

756-1756-50

Indicates Canadian Model Number: call �-800-305-6953 to order

www.white-rodgers.com�52

AP

PL

IAN

CE

FLUSH MOUNT FAN OR LIMIT CONTROLSIdeal for Replacement of Similar Type ControlsFEATURES• For use where space is limited.• Small bimetal sensing element.• Snap-Action switch.• Fan control has adjustable range with direct reading temperature dial.• 758 has adjustable limit setting.

SPECIFICATIONSDimensions for 757 & 758 . . . . . . . . . . . . �”H x 3”W x ��/4”D

775-1

Motor Rating Model Switch Full Load Pilot Number Description Range Differential Action 120 VAC 240 VAC Duty 757-1 Fan 70 to �60°F ➀ Fixed 25°F Close on Rise 8.0 A 4.0 A �25 VA (2� to 7�°C) (�4°C) 758-1 Limit ��0 to 200°F ➁ Fixed 25°F Open on Rise 8.0 A 4.0 A �25 VA (43 to 93°C) (�4°C)

➀ Cut-in setting (cut-out is cut-in setting minus the differential)➁ Cut-out setting (cut-in is cut-out setting minus the differential)

SNAP DISC CONTROLS/FLUSH MOUNT FAN LIMIT/ATTIC FAN

757-1

ATTIC FAN CONTROLUniversal Style Adjustable Fan Control

FEATURES• Rugged metal enclosure.• Universal mounting tabs.• Adjustable temperature setting.• Built-in thermal limiter.

SPECIFICATIONSDimensions for 775. . . . . . . . . . . . . . . . . . 2.8”H x 3.59”W x 2.02”D

Motor Rating Model Switch Full Load Pilot Number Description Range Differential Action 120 VAC 240 VAC Duty 775-1 Attic Fan Control 60 to �20°F ➀ Fixed �0°F Close on Rise 9.0 A — — with Thermal Limiter (�5 to 49°C) (6°C)

➀ Thermal limiter opens at �83°F (84°C)

www.white-rodgers.com �53

AP

PL

IAN

CE

APPLIANCE VALVES

2500 SERIES REPLACEMENT GAS VALVE COILSFEATURES• Easy installation of replacement coil assemblies.• Available for most popular models.• Single or complete coil sets

F91-3890

F91-3889 Model OEM Number Application Description Type F91-3889 25M0�A-xxx �20V Secondary Coil Replacement for Used on Whirlpool, 25M Valve Individual Pack Secondary Coil GE, Maytag, Speed Queen, F91-3890 25M0�A-xxx �20V Coil Replacement for Fridgidare, Amana, Booster and Holding Coil current production (since �985)

25M01A-100 AND 25M01A-10125M0�A Series Gas Valves Combine a Gas Pressure Regulator withRedundant and Main Solenoid Valves for Hot Surface Ignition (HSI)Residential Gas Clothes Dryers. Two Models to Replace Virtually AllWhirlpool, Maytag, GE, Frigidaire, or Speed Queen Gas Dryer Valves

FEATURES• Compact split coil design.• Inlet/outlet screen.• Field-adjustable regulator.• Replaceable operating coils (no gas interruption).• Outlet pressure tap.• Both models packaged with the most popular main burner orifices to replace many OEM models.

SPECIFICATIONSType of Gas . . . . . . . . . . . . . . . . . . . . . Natural or LP gas (conversion kit included)Pressure Regulator Setting . . . . . . . . . Nat. Gas: 2.5” to 5.4” W.C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LP Gas: 7.0” to �2.0” W.C.Operating Ambient . . . . . . . . . . . . . . . . Temperature: 32° to �55°FMax. Pressure Rating. . . . . . . . . . . . . . �4” W.C. (½ PSI) max.Electrical . . . . . . . . . . . . . . . . . . . . . . . . �20 VAC, 60 Hz, .06 amps�” P.D. Capacity . . . . . . . . . . . . . . . . . . 40,000 BTU/HR

PARTS AND ACCESSORIES• F9�-3889 — Replacement Coil (Individual)• F9�-3890 — Replacement Coil (Boost/Hold)

25M GASDRYER VALVES

Model Coil Outlet Flow Inlet/Outlet Regulator Number Voltage Direction Size Adjustment Range 25M01A-100 �20 VAC Right Angle Left 3/8”NPTX11/32” Nat.Gas:2.5”to5.4”W.C. 25M01A-101 �20 VAC Right Angle Right 3/8”NPTX11/32” LPGas:7.0”to12.0”W.C. (ConversionKitIncluded)

Mounting Position – Control may be mounted in the following positions: horizontal, vertical or 90° of horizontal.Do not mount upside down.

NEW!

NEW!

25M01A-101