200
SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface)

imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 1 Tuesday, September 23, 2003 5:31 PM

S O F T W A R E G U I D E

VT-100i m a g e R A I D® S e r i e s S t o r a g e S y s t e m

( M e n u - b a s e d U s e r I n t e r f a c e )

Page 2: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 2 Tuesday, September 23, 2003 5:31 PM

Page 3: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 3 Tuesday, September 23, 2003 5:31 PM

VT-100i m a g e R A I D® S e r i e s S t o r a g e S y s t e m

( M e n u - b a s e d U s e r I n t e r f a c e )

S O F T W A R E G U I D E

Page 4: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 4 Tuesday, September 23, 2003 5:31 PM

Fujitsu Europe Limited

Restricted Rights and Liability

No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, recording, or otherwise, in whole or part, without prior written permission from Fujitsu Europe Limited.

Fujitsu Europe Limited shall not be liable for any damages or for the loss of any information resulting from the performance or use of the information contained herein. Your rights to the software are governed by the license agreement included with any accompanying software. Fujitsu Europe Limited reserves the right to periodically revise this manual without notice. Product features and specifications described are subject to change without notice.

Copyright

Fujitsu Europe LimitedHayes Park CentralHayes End RoadHayes, Middlesex, England UB4 8FE

Copyright © 2003 Fujitsu Europe Limited. All Rights Reserved.

imageRAID and the imageRAID logo are registered trademarks of Fujitsu Europe Limited, Fujitsu is a registered trademark of Fujitsu Limited.

Other company and product names herein may be trademarks or registered trademarks of their respective companies.

Page 5: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Contents

imageRAID-MUI.book Page i Tuesday, September 23, 2003 5:31 PM

About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vWelcome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vNumbering Convention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viTypographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi

1 Accessing the Configuration Utility Software . . . . . . . . . . . . . . . . . 1Using the VT-100 Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2Navigating the RAID Configuration Software . . . . . . . . . . . . . . . . 4Menu System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Controller Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Troubleshooting Assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2 Creating Disk Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Optimization and Drive Selection for RAID 5 Arrays . . . . . . . . . . 13

Creating Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Configuring Array Read-Ahead and Writeback Cache . . . . . . . . . 26Read-Ahead Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Writeback Cache . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Assigning Hot Spare Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Delete Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Expanding an Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Adding Additional Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Adding Additional Sub-Arrays . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Trust an Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

3 Disk LUNs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Accessing the LUN Configuration Menu . . . . . . . . . . . . . . . . . . . 48Viewing Unassigned Free Space . . . . . . . . . . . . . . . . . . . . . . . . . 49

i

Page 6: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Table of Contents

ii

imageRAID-MUI.book Page ii Tuesday, September 23, 2003 5:31 PM

Creating a Disk LUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Expand a LUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Set LUN Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Delete a LUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Modify Mapped LUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60

4 SAN LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

Accessing the SAN LUN Mapping Configuration Menu . . . . . . . . 64Viewing SAN LUN Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Creating a SAN LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . 66Delete SAN LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Modify SAN LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Viewing Connected Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

5 Advanced Configuration and Management . . . . . . . . . . . . . . . . . . 83Rebuild Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Enable/Disable Auto Rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . 83Auto Hot Spare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

Hot Spare Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Viewing the List of Hot Spare Drives . . . . . . . . . . . . . . . . . . . . . 87Adding or Removing Hot Spare Drives . . . . . . . . . . . . . . . . . . . 89

Hardware Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . 91Controller LUN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Port ID Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93Controller Port Different Node Name . . . . . . . . . . . . . . . . . . . . . 95Controller Port Connection Options . . . . . . . . . . . . . . . . . . . . . . 97Controller Port Data Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99RS-232 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102

Viewing Controller Information . . . . . . . . . . . . . . . . . . . . . . . . . 104Clearing the Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106UPS Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108

6 Additional Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Modify Configuration Name . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Modify Configuration WWN . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Setting Single Controller Mode . . . . . . . . . . . . . . . . . . . . . . . . . 115Background Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116Controller SES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118

Page 7: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Table of Contents

imageRAID-MUI.book Page iii Tuesday, September 23, 2003 5:31 PM

7 Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121View All Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121

Dump. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Access Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Readahead Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126Command Cluster Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Miscellaneous Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129View Access Statistics on Each LUN . . . . . . . . . . . . . . . . . . . . . . 130Clear Access Statistics on Each LUN . . . . . . . . . . . . . . . . . . . . . . 131Clear Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132

8 Event Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Accessing Event Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Controller Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Drive Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Controller Port Loop (Host) Events . . . . . . . . . . . . . . . . . . . . . . . 150SES Events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Failed Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Clear Event Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155

9 Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157Offline Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Drive Loop Integrity Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160

Online Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165Controller Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166Drive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169

Download the Firmware from the Host . . . . . . . . . . . . . . . . . . 169Read Firmware from a Drive to the Buffer . . . . . . . . . . . . . . . . 171

RAID 5/50 Parity Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173Command Tracing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175

Shutdown Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177Diagnostics Dump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178

A Optimizing RAID 5 Write Performance . . . . . . . . . . . . . . . . . . . . . . 179Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179Sequential Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180Number of Outstanding Commands . . . . . . . . . . . . . . . . . . . . . . 180Access Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181Access Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181RAID 5 Sub-Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182

iii

Page 8: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Table of Contents

iv

imageRAID-MUI.book Page iv Tuesday, September 23, 2003 5:31 PM

Multiple Drive Failures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Faster Rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185

Page 9: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Preface

imageRAID-MUI.book Page v Tuesday, September 23, 2003 5:31 PM

About this Manual

Welcome

Congratulations on the purchase of your new imageRAID™ Series Storage System

from Fujitsu Europe Limited. This guide provides the operational and reference

information to configure and manage the imageRAID Controllers installed in your

storage system. The controllers are accessed through a VT-100 terminal using a

menu-based user interface, connected directly to the RAID Controllers.

Although the target audience is experienced system administrators who are

familiar with the principles and conventions of Small Computer System Interface

(SCSI), Fibre Channel Interface, and Redundant Array of Independent Disk

(RAID) technology, you will find step-by-step procedures to perform

configuration functions and enclosure monitoring.

v

Page 10: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

About this Manual

vi

imageRAID-MUI.book Page vi Tuesday, September 23, 2003 5:31 PM

Numbering Convention

The capacity of most disk drives is reported from the Controller using decimal GB

(1 GB = 1,000,000,000 bytes). Many operating systems use the definition of 1 GB

= 1,073,741,824 bytes. This can cause a discrepency of approximately 7%

between what the controller reports and what the operating system reports.

Therefore, a drive labeled 73 GB has a true physical capacity of 68 GB (binary).

NOTE: The RAID Controller also reserves some capacity for configuration data.

Typographical Conventions

The following typographical conventions are used in the user’s guide:

� Menu items are displayed in the format: “Array Configuration menu,

choose View Unused Drives.”

� Code font will indicate literal text used in examples.

� Italic code font indicates a replaceable or variable item in code.

� Italic text indicates the item that is selected or chosen.

� Key strokes are enclosed in brackets, e.g., <Esc>, <K>, or <Enter>.

Numbering Convention

Page 11: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1

imageRAID-MUI.book Page 1 Tuesday, September 23, 2003 5:31 PM

Accessing the Configuration Utility Software

The menu-based user interface is used to control and manage the imageRAID

Controllers. You can:

� Create and manage disk arrays

� View detailed information about each controller

� Manage drive spares

� Configure the controller

� Monitor system status

� Manage disk drives and enclosures

� Perform Online and Offline Diagnostics

� Review Event Logs

Access to the controllers is via a VT-100 terminal connected to the RS-232 serial

ports on the controller’s rear panel. Configure your terminal using the parameters

described on the following page.

NOTE: Access to each RAID Controller is provided through independent

controller serial ports.

1

Page 12: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

2

imageRAID-MUI.book Page 2 Tuesday, September 23, 2003 5:31 PM

Using the VT-100 Terminal

Access to the imageRAID Controller is via its onboard Configuration Utility

software using a VT-100 terminal and the RS-232 serial ports on the controller.

A null-modem serial cable is used to connect the terminal to the serial port on the

controller.

Configure your host system or terminal RS-232 port to use the following settings

Set the communications parameters for the terminal program are as follows

To access the imageRAID Controllers

1 Power on the imageRAID Storage System.

2 From the computer or terminal connected to the RAID Controller, start your

terminal emulation software.

Be sure that your terminal emulation software is set to use the correct COM

port on your computer.

3 From the terminal window, press the <Control> + <W> keys.

Setting Value

Terminal Emulation ANSI

Function Terminal Keys

Fonts Terminal

Translations None

Columns 80

Setting Value

Baud Rate 115,200

Data Bits 8

Stop Bits 1

Parity None

Flow Control None

Connector COM1 (typically)

Using the VT-100 Terminal

Page 13: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

imageRAID-MUI.book Page 3 Tuesday, September 23, 2003 5:31 PM

Main Menu Screen

You can now perform all of the functions described in the following chapters. All

steps begin from the Main Menu.

If an event or error occurs, you can review the log for the problem by

examining the event log.

Using the VT-100 Terminal 3

Page 14: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

4

imageRAID-MUI.book Page 4 Tuesday, September 23, 2003 5:31 PM

Navigating the RAID Configuration Software

The RAID Configuration utility menu system can be navigated using the keys on

your keyboard. The table below describes the primary navigation and selection

methods.

To Do this

Toggle interface from text-base to menu-based.

Press <Control> + <W> keys.

Return to the previous menu or screen (Exit).

Press the <Esc> key.

Move the selection. Press the <Space Bar> key.

Select a menu option. Press the <Enter> key.

Navigating the RAID Configuration Software

Page 15: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

imageRAID-MUI.book Page 5 Tuesday, September 23, 2003 5:31 PM

Menu System

Configuration Utility Menu Chart 1 of 3

Main Menu

Configuration MenuController InformationStatisticsEvent LogsDiagnostics

Configuration Menu

Main Menu

View ConfigurationArray ConfigurationLUN ConfigurationHot Spare ConfigurationRebuild ParametersUPS ConfigurationHardware ConfigurationClear ConfigurationAdditional Configuration

Controller Information

View Controller 0View Controller 1

View Controller 0View Controller 1

View Controller 0View Controller 1

Statistics

Event Logs

Displays controller information.

Clears All Configurations

Additional Configuration

View ArrayCreate ArrayDelete ArrayExpand ArrayArray Cache ConfigurationView Unused DrivesAdvanced Array Configuration

Array Configuration

LUN Configuration

Hardware Configuration

LUN ManagementSAN LUN Mapping

Controller LUNPort ID SettingsController Port Different Node NameController Port Connection OptionsController Port Data RateRS232 Settings

Modify Configuration NameModify Configuration WWNSet Single Controller ModeBackgroun VerificationController SES Events

Hot Spare ConfigurationView Hot Spare Drive ConfigurationAdd or Remove Pool and Dedicated Spare

Rebuild ParametersAuto Rebuild and Set PriorityAuto Ho Spare

Diagnostic

Offline DiagnosticsOnline DiagnosticsReset ControllerShutdown ControllerDiagnostics Dump

Menu System 5

Page 16: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

6

imageRAID-MUI.book Page 6 Tuesday, September 23, 2003 5:31 PM

Menu System (continued)

Configuration Utility Menu Chart 2 of 3

RS232 Setting1152005760038400192009600

Port ID Selection

View ArrayCreate ArrayDelete ArrayExpand ArrayArray Cache ConfigurationView Unused DrivesAdvanced Array Configuration

Array Configuration Menu

LUN Configuration Menu

Hardware Configuration Menu

LUN ManagementSAN LUN Mapping

Controller LUNPort ID SettingsController Port Different Node NameController Port Connection OptionsController Port Data RateRS232 Settings

Hot Spare Configuration MenuView Hot Spare Drive ConfigurationAdd or Remove Pool and Dedicated Spare

Rebuild Parameters MenuAuto Rebuild and Set PriorityAuto Hot Spare

Auto Rebuild: Disabled Rebuild Priority: 50%

LUN ManagementView LUNCreate LUNExpand LUNSet LUN AvailabilityDelete LUNView Unassigned Free SpaceModify Mapped LUN Number

SAN LUN MappingView SAN LUN MappingsCreate SAN LUN MappingDelete SAN LUN MappingModify SAN LUN MappingView Connected Hosts

Create Array

Initialize ArrayTrust Array

Displays Array Information

Displays the Unused Drives

Displays Spare Drives

Select an Array Add Drives to the Array Add Sub-Arrays to Current Array

Read-Ahead CacheWriteback Cache

Set Controller 0/1 Port 0 Connection OptionSet Controller 0/1 Port 1 Connection Option

Set Controller 0/1 Port 0 Data RateSet Controller 0/1 Port 1 Data Rate

Enable/Disable

Controller 0/1 Port 0 Hard Address: 04Controller 0/1 Port 1 Hard Address: 05

Controller LUN Number: 000 Current

Auto Hot Spare: Disabled

Select an Array Delete the Array

Select DriveAdd/Remove

Steps through thecreate array process.

Menu System

Page 17: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

imageRAID-MUI.book Page 7 Tuesday, September 23, 2003 5:31 PM

Menu System (continued)

Configuration Utility Menu Chart 3 of 3

Displays Controller Parameters

Select LUN

View Access Statistics on Port 1View Access Statistics on Port 2View Access Statistics on Both Ports

Select LUN

Clear Access Statistics on Port 1Clear Access Statistics on Port 2Clear Access Statistics on Both Ports

View All StatisticsView Access StatisticsView Readahead StatisticsView Command Clustering StatisticsView Miscellaneous StatisticsClear StatisticsView Access Statistics On Each LUNClear Access Statistics On Each LUN

View All EventsView New EventsView Last 50 EventsView Last Hour EventsView Last 24 Hours EventsView Drive Loop EventsView Controller Port Loop EventsView Environment EventsView Failed Drive ListClear Event Log

Controller Information

View Controller 0View Controller 1

View Controller 0View Controller 1

View Controller 0View Controller 1

Statistics

Event Logs

Menu System 7

Page 18: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

8

imageRAID-MUI.book Page 8 Tuesday, September 23, 2003 5:31 PM

Controller Information

Detailed information on the RAID Controller is available through the VT-100

interface and includes:

� Controller WWN

� Firmware Information

� Run-time Information

� Loop Information

� Temperature and Voltage Information

To view controller information:

1 After the controller(s) have completed booting, enter the Main menu by

pressing the <Control>+<E> keys.

2 From the Main menu, choose “Controller Information” and press <Enter>.

Main Menu Screen

3 Select the controller you wish to examine. Use the <Space Bar> to select the

controller and press <Enter>. If only one controller is present, only one

selection is listed.

Controller Information

Page 19: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

imageRAID-MUI.book Page 9 Tuesday, September 23, 2003 5:31 PM

Below is an example of the controller information screen.

Controller Information Display Screen

The following is a brief summary of the information displayed.

Error Description

Controller WWN An 8-byte unique World Wide Name the controller uses for identification. This is unique to each controller, and programmed at manufacture.

Configuration WWN An 8-byte World Wide Name the controller uses for identification to hosts. This may be identical to the Controller WWN, or may be different if the configuration was initially not created with this particular controller. This remains constant even if controllers are replaced. It is possible to modify this to use the WWN of either controller.

Controller Information 9

Page 20: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 1 - Accessing the Configuration Utility Software

10

imageRAID-MUI.book Page 10 Tuesday, September 23, 2003 5:31 PM

Troubleshooting Assistance

To assist you when troubleshooting problems with your system, the Events

Chapter provides a list of all the events along with a complete description, and a

suggested cause and action. When events occur, you can refer to the specific

event in that chapter, review a complete description of the event then determine

the possible cause or possible causes and the suggested action to take.

Config Name A 64-byte ASCII name used to identify a specific controller configuration.

Firmware Revision The firmware version in use by the controller.

Firmware Date/Time Date and time of when the firmware was created.

Total Power on Count The number of times this controller has been power cycled.

Total Power on Time The total length of time this controller has been powered on.

Current Power on Time The length of time since this controller has last been powered on or reset.

Current Controller Time This is the current time on the controller.

Last Configuration Time This is the time the controller was last configured.

Last Configuration Time This is the time the controller was last configured.

Controller Port Loop x Status The current status of the specified controller port loop.

Drive Loop x Status The current status of the specified drive loop.

Onboard Temperature This is the current temperature as measured by the controller. If this value exceeds predefined limits, an event will be written into the event log.

Controller Voltage Current readings for various controller and coprocessor voltages.

Error Description

Troubleshooting Assistance

Page 21: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2

imageRAID-MUI.book Page 11 Tuesday, September 23, 2003 5:31 PM

Creating Disk Arrays

Configuring a RAID system requires some planning to ensure that you define the

correct RAID level and array options. It may be helpful to refer to the Topology

chapter in the imageRAID Storage System User’s Guide.

This chapter will step you through the process to configure your arrays. You are

then directed to the next chapter for the procedures to define the Host LUNs

which makes the drive array(s) available to the operating system.

This manual assumes you have a basic understanding of RAID concepts and

terminologies.

Arrays

You can create an array at any time. The table below describes the drive

requirements for each RAID level.

Drive Requirements by RAID Level

RAID Level Minimum No. of Drives Maximum No. of Drives

0 1 16

1 2 16

5 3 16

50 6 16

10 (Mirrored) 4 16

11

Page 22: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

12

imageRAID-MUI.book Page 12 Tuesday, September 23, 2003 5:31 PM

NOTE: Before you create more than one array, you must be sure that your host

operating system supports multiple Logical Unit Numbers (LUNs). Most

operating systems do support multiple LUNs, or have an option for it. If

your operating system does not support multiple LUNs, the host will only

be able to see one array at the first disk LUN.

Terminology

The following describes the terminology used when creating and managing array’s.

Term Description

Array A group of disk drives that are combined together to create a single large storage area. Up to 64 arrays are supported, each containing up to 16 drives per array. There is no capacity limit for the arrays.

Chunk Size This is the amount of data that is written on a single drive before the controller moves to the next drive in the stripe.

Stripe Size This is the number of data drives multiplied by the chunk size.

Cache Flush Array This is the array that is used to automatically flush cache data in the situation where power has failed to some of the drives.

Initialization RAID 5/50 arrays must have consistent parity before they can be used to protect data. Initialization writes a known pattern to all drives in the array. If the user chooses not to initialize an array, this is known as a “trusted array” and any drive failure will result in data corruption. It is possible to later perform a parity rewrite, which recalculates the parity based on the current data, thus ensuring the data and parity are consistent.

Reserved Capacity In order to allow drives from a different family or manufacturer to be used as a replacement for a drive in an array, it is recommended that a small percentage of the drive’s capacity be reserved when creating the array. This is user selectable, from 0 to 10 percent.

RAID Level 0 RAID 0 is defined as disk striping where data is striped or spread across one or more drives in parallel. RAID 0 is ideal for environments in which performance (read and write) is more important than fault tolerance or you need the maximum amount of available drive capacity in one volume. Drive parallelism increases throughput because all disks in the stripe set work together on every I/O operation. For greatest efficiency, all drives in the stripe set must be the same capacity. Because all drives are used in every operation, RAID 0 allows for single-threaded I/O only (i.e., one I/O operation at a time). Environments with many small simultaneous transactions (e.g., order entry systems) will not get the best possible throughput.

Terminology

Page 23: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 13 Tuesday, September 23, 2003 5:31 PM

Optimization and Drive Selection for RAID 5 Arrays

Typical RAID 5 implementations require a number of steps to write the data to

the drives. In order to optimize your system performance based on the type of

writes you expect in your operation, we have provided detailed information on

optimizing the performance using full strip write operations in an appendix.

If you intend to setup a RAID 5 array and wish to consider optimum

performance, you will need to consider the number of drives, parity drives,

chunk size, and should review the information provided in “Optimizing RAID 5

Write Performance” on page 179. Additional information is provided at the

appropriate step during configuration.

RAID Level 1 RAID 1 is defined as Disk mirroring where one drive is an exact copy of the other. RAID 1 is useful for building a fault-tolerant system or data volume, providing excellent availability without sacrificing performance. However, you lose 50 percent of the assigned disk capacity. Read performance is somewhat higher than write performance because Microsoft Windows NT reads data off the drive whose head is closest to the desired sector (called locality of reference); all write operations are made to both disks simultaneously.

RAID Level 5 RAID 5 is defined as disk striping with parity where the parity data is distributed across with parity all drives in the volume. Normal data and parity data are written to drives in the stripe set in a round-robin algorithm. RAID 5 is multi threaded for both reads and writes because both normal data and parity data are distributed round-robin. This is one reason why RAID 5 offers better overall performance in server applications. Random I/O benefits more from RAID 5 than does sequential I/O, and writes take a performance hit because of the parity calculations. RAID 5 is ideal for database applications.

RAID Level 10 RAID 10 is defined as mirrored stripe sets or also known as RAID 0+1. You can build RAID 10 either directly through the RAID controller (depending on the controller) or by combining software mirroring and controller striping, or vice versa (called RAID 01).

RAID Level 50 This RAID level is a combination of RAID level 5 and RAID level 0. Individual smaller RAID 5 arrays are striped, to give a single RAID 50 array. This can increase the performance by allowing the controller to more efficiently cluster commands together. Fault tolerance is also increased, as one drive can fail in each individual array.

Sub-array In RAID 50 applications, this is the name given to the individual RAID 5 arrays that are striped together. Each sub-array has one parity drive.

Optimization and Drive Selection for RAID 5 Arrays 13

Page 24: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

14

imageRAID-MUI.book Page 14 Tuesday, September 23, 2003 5:31 PM

Creating Arrays

Configuring the controllers for arrays involves a few simple steps. Each controller

only stores its RS-232 settings internally, all other configuration parameters

(i.e., array specific settings) are stored on all disk drives that are attached to the

controller(s). This makes it possible to remove and replace controllers without

requiring any configuration changes. The configurations can be viewed or

modified through either controller’s RS-232 port.

NOTE: It is recommended that you make notes about the arrays you create in the

event you would be required to duplicate the configuration for an array.

Refer to “Trust an Array” on page 45.

No changes are made until the configuration is saved, so it is possible to quit at

any time without affecting the current configuration as long as you don’t save

those changes. Configuration can be performed while the system is active.

To create an array:

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu

If this is not a first run for new controllers, you may wish to view any present

configuration, otherwise skip step 2.

Creating Arrays

Page 25: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 15 Tuesday, September 23, 2003 5:31 PM

2 (Optional) Choose View Configuration and press <Enter>. Press <Esc> to

return to the previous menu.

Configuration Menu

The following screen appears:

View Configuration Screen

Creating Arrays 15

Page 26: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

16

imageRAID-MUI.book Page 16 Tuesday, September 23, 2003 5:31 PM

3 Access the Array Configuration menu, choose Array Configuration and press

<Enter>.

The Array Configuration menu allows the logical arrays to be reviewed,

created, deleted, or otherwise modified.

Array Configuration Menu

View Configuration Field Explanation

Field Description

No. Drive number in the array.

World Wide Name 8-byte Node Name, which is unique for every drive.

Product ID Drive model number.

F/W Drive firmware version.

Sav Indicates whether a copy of the drive’s firmware is saved on the media.

Ser. No. Drive serial number.

Cap. Drive capacity expressed in GBs.

IDx Loop ID of the specified drive loop.

HID Hard addresss of the drive.

EN, SL The enclosure and drive slot number, used for drive identification.

ST The drive status, will either be “OK” or “FL.”

Creating Arrays

Page 27: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 17 Tuesday, September 23, 2003 5:31 PM

Next, you will most likely wish to view the unused drives before creating a

new array.

4 From the Array Configuration menu, choose View Unused Drives and press

<Enter>.

View Unused Drives Screen

Unused Drives Screen

Press <Esc> to return to the previous screen.

Creating Arrays 17

Page 28: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

18

imageRAID-MUI.book Page 18 Tuesday, September 23, 2003 5:31 PM

5 Create a new array.

From the Array Configuration menu, choose Create Array and press <Enter>.

Create Array Screen

6 Enter a name for the array and press <Enter>.

You may use up to 32 characters.

Array Name Screen

Creating Arrays

Page 29: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 19 Tuesday, September 23, 2003 5:31 PM

7 Select a RAID level. Highlight the appropriate choice and press <Enter>.

NOTE: The menus that will follow are mostly identical for all RAID levels,

however RAID 5/50 is used in this example.

RAID Level Screen

8 From the Configuration Type screen, highlight Manual Configuration and

press <Enter>.

Configuration Type Screen

Creating Arrays 19

Page 30: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

20

imageRAID-MUI.book Page 20 Tuesday, September 23, 2003 5:31 PM

9 Specify the chunk size for the array. Highlight the selected chunk size and

press <Enter>.

The available chunk sizes are 64K, 128K, and 256K. This is the amount of

data that is written on a single drive before the controller moves to the next

drive in the stripe.

To achieve optimum RAID 5 write performance you should consider setting

the chunk size based on the specified number of drives for a Full Stripe Write

when configuring RAID 5/50 arrays. Refer to “Optimizing RAID 5 Write

Performance” on page 179 for detailed information.

Chunk Size Screen

The primary aim of setting a chunk size is to try to set a stripe size that allows

for full stripe writes. The stripe size is determined by the number of data

drives multiplied times the chunk size, (8 data drives * 64K chunk size = 512

strip size).

For maximum performance with RAID 5/50 arrays, you want to do as many

full stripe writes as possible. Typically, Windows NT/2000 accesses at 64K,

therefore a stripe size of up to 1 MB would mean the controller has to cluster

16 commands to perform a full stripe write (actually 17 because of

alignment). If you were to use a larger stripe size, then you run the risk of

not being able to cluster sufficiently for the application.

Creating Arrays

Page 31: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 21 Tuesday, September 23, 2003 5:31 PM

In cases where you are performing larger writes to the controller, then you

could go up to 2 MB for a stripe size, since you have more data to cluster.

Never exceed 2 MB for a stripe size, since the controller cannot cluster over

this size.

It is recommended to keep the stripe size to 1 MB or less for general use,

perhaps increasing it for specific applications. This stripe size is actually the

substripe size in RAID 50 cases. A 4+1 array (4 data and 1 parity drives) with

a 256K chunk has a 1 MB stripe size, as does an 8+1 array with 128K stripe

size, and an 8+2, RAID 50 array with 256K chunk size.

Although 8+1 gives an even stripe size, this does not really matter for an

operating system (OS) that writes in significantly smaller chunks. So, 8+1,

10+1, or 11+1 with a chunk size of 64K would be fine for an OS that does

64K writes. If the OS does much larger writes, then you may want to increase

the chunk size. With writeback cache enabled, then the controller can keep

data and do a full stripe write.

For a single enclosure example - best all around performance:

11+1 with 64K chunk size would yield a 704K stripe (11*64=704)

10+2 with 128K chunk size would yield a 640K stripe (5*128=640)

When using more drives, 14+2 (64K), or 12+3 (128K) should be as good

as 12+4. However, it is recommended to keep to a minimum of 4 data

drives for a subarray.

For most sequential accesses, the difference may not be too much for

different configurations. However, for large block random writes, it can help

if the stripe size is similar to the I/O size. This allows the controller to

perform a parital full stripe write, where it has most of the data for a full

stripe, and can just read some from the drives to complete the stripe.

While Windows NT/2000 does 64K accesses, these are not aligned. If the

chunk size is 64K, every access crosses a chunk boundary and so involved

two read/modify/write commands instead of one. However, since the

controller can cluster, this problem is somewhat offset since the controller

usually can cluster sufficiently to do full stripe writes. If it is a completely

random 64K access on Window NT/2000, then a 64K chunk is not the best,

rather 128K or 256K is better to minimize the number of commands that

cross chunk.

Creating Arrays 21

Page 32: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

22

imageRAID-MUI.book Page 22 Tuesday, September 23, 2003 5:31 PM

Larger chunk sizes should be used if the OS is writing large blocks, or with

large sequential writes where the controller can cluster sufficiently. Always

keep the stripe size below 2 MB.

10 Select the drives for the array.

The controller will list all the available drives for each attached enclosure(s).

You can choose to add a drive to the array by pressing the <U> key on the

highlighted drive. Or you may select all the available drives by pressing the

<A> key. Press the <R> key to remove a drive that has been selected, or press

the <C> key to remove all the drives selected.

Press the <Ctrl>+<D> keys when you have completed your selections to

continue.

Select Drives Screen

If you have multiple enclosures, the enclosure you are viewing is displayed

at the top of the page. To move to the drives in the next enclosure, move the

highlight to the last drive in the column or row and press the right/down

arrow key.

Creating Arrays

Page 33: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 23 Tuesday, September 23, 2003 5:31 PM

11 Choose the drive capacity reserve. Type the correct <value> and press <Enter>.

This determines how much drive capacity to reserve for future capacity

fluctuations of replacement drives. (This is not applicable to RAID 0

configurations.) The default is 1%.

Drive Capacity Reserve Screen

12 Enter the number of sub-arrays by highlighting the appropriate sub-array

displayed and press <Enter>.

Sub-Array Selection Screen

Creating Arrays 23

Page 34: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

24

imageRAID-MUI.book Page 24 Tuesday, September 23, 2003 5:31 PM

The controller displays the number of available sub-arrays you may choose

from. In this example, the first one is a single sub-array that provides nine

data drives and one parity drive, and the second example is two sub-arrays

that provides two four drive sub-array with one parity drive.

When you create a redundant array, such as a RAID 5 or 50 type, you will

always be creating at least one sub-array comprised of the data drives and

one parity drive. When a sufficient number of drives have been selected you

may choose to make multiple sub-arrays of your array. This provides the

benefits of a quicker recovery from a drive failure since only one of the

smaller sub-arrays is affected.

If this is just one single array with less than five disk drives, choose the

default of one sub-array.

13 Initalize the array, highlight Initialize Array and press <Enter>.

For details on trusting arrays, refer to “Trust an Array” on page 45.

Initialize/Trust Array Screen

NOTE: You must initialize the array before using the logical drives created

from the array.

14 Save the configuration to create the array. Highlight Yes and press <Enter>.

Otherwise select No to cancel and return to the Main menu.

Creating Arrays

Page 35: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 25 Tuesday, September 23, 2003 5:31 PM

Save Configuration Screen

You will see a message that the configuration is being saved. Once it has

completed the process, press any key to continue.

Continue with setting up the Array Read-Ahead Cache and Writeback Cache on

the following page, then the Hot Spare drives options.

Afterwards go to the next chapter and configure the Host LUN assignment to

complete the setup to make the logical drives available for use.

Creating Arrays 25

Page 36: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

26

imageRAID-MUI.book Page 26 Tuesday, September 23, 2003 5:31 PM

Configuring Array Read-Ahead and Writeback Cache

The following steps will guide you through configuring the Read-Ahead Cache

and Writeback Cache options for each array. Each array has a different set of

cache settings. You will need to set these options for each array you have created.

NOTE: Read-Ahead Cache and Writeback Cache thresholds work together to

allow fine tuning of the I/O performance.

Read-Ahead Cache

The Read-Ahead function improves the data retrieval performance by allowing the

controller to read into cache a full stripe of data at one time, which greatly

improves the cache hits. For smaller transfers the Read-Ahead algorithm can

improve performance. If, for example, the stripe size is 256KB (chunk size

multiplied by the number of data drives) and the host request 64KB of data, when

Read-Ahead is enabled the controller will read in advance a full 256KB. When the

host request the next 64KB block, the data will already be in the cache.

Depending on the data patterns for your application, disabling the Read-Ahead

Cache can help load balance the reads and write operations, which can increase

performance.

1 From the Array Configuration menu, select Array Cache Configuration and

press <Enter>.

Array Configuration Menu

Configuring Array Read-Ahead and Writeback Cache

Page 37: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 27 Tuesday, September 23, 2003 5:31 PM

2 From the Array Cache Configuration menu, select Read-Ahead Cache and

press <Enter>.

Array Cache Configuration Menu

3 Select an array from the list to which you wish to make changes. Use the

up/down arrow keys to select an array and press <Enter>.

Select Array Screen

4 Choose a Read-Ahead Cache parameter to use for the selected array. Use the

up and down arrow keys to select and <Ctrl>+<D> keys to save the changes.

Read-Ahead Cache 27

Page 38: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

28

imageRAID-MUI.book Page 28 Tuesday, September 23, 2003 5:31 PM

Read-Ahead Cache Parmaters Screen

The choices are automatic, disabled, and four pre-determined sizes. Select

Automatic, which is the the default and the recommended setting. It allows

the controller to determine the optimum setting. Disabled will turn off the

Read-Ahead Cache. Choose one of the pre-determined sizes to optimize the

read performance based on your data patterns.

5 Save the configuration changes. Highlight Yes and press <Enter>, or No to

cancel.

Save Configuration Screen

Read-Ahead Cache

Page 39: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 29 Tuesday, September 23, 2003 5:31 PM

Writeback Cache

In a writeback cache operation, data is sent to the controller from the host and

the controller immediately responds to the host confirming the data was received

and written to the media. The host may then send more data. This can

significantly increase performance for host systems that only send a low number

of commands at a time. The controller caches the data, and if more sequential

data is sent from the host, it can cluster the writes together to increase

performance further. If sufficient data is sent to fill a stripe in RAID 5/50

configurations, the controller can perform a Full Stripe Write, which significantly

reduces the write overhead associated with RAID 5/50.

Disabling writeback cache ensures that the data is sent to the drives before status

is returned to the host. With writeback cache enabled, if a short term power

failure occurs, the battery back-up unit provides adequate power to ensure that

cache is written to disk when the power is restored. In duplex operations, the

cache is mirrored to both controllers which provides further redundancy in the

event of a single controller failure.

Mirrored cache is designed for absolute data integrity. The cache in each storage

processor contains both primary cached data for the disk groups it owns, and a

copy of the primary data of the other storage processor. Mirrored cache ensures

that two copies of cache exist on both storage processors, before confirming to

the operating system that the write has been completed.

Below is a table from the imageRAID Storage System User’s Guide, which list the

hold-up times for data for the battery backup unit.

Normally, write-intensive operations will benefit through higher performance

when writeback cache is enabled on that array. Read-intensive operations, such

as a streaming server, may not benefit from writeback cache.

BBU Battery Hold-Up Times

ConfigurationMemory Vendor and

Part NumberMeasured

Current DrawAbsolute Maximum

Backup TimeExpected Safe Backup Time

Main board only w/512 MB

Kingston KVR100X72C2/512

27.9mA 41.2 hours 20.6 hours

Main board w/512 MB and Coprocessor w/512 MB

Kingston KVR100X72C2/512

48.3mA 23.8 hours 11.9 hours

Writeback Cache 29

Page 40: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

30

imageRAID-MUI.book Page 30 Tuesday, September 23, 2003 5:31 PM

The Writeback Cache is used to optimize the write performance specific to your

data patterns. In general, larger cache sizes will increase the write performance

but may lower simultaneous read performance. The recommended size is 16 MB.

The strategy of write operations results in a completion signal being sent to the

host operating system as soon as the cache receives the data to be written. The

disk drives will receive the data at a more appropriate time in order to increase

controller performance.

1 From the Array Configuration menu, select Array Cache Configuration and

press <Enter>.

Array Configuration Menu

2 From the Array Cache Configuration menu, select Writeback Cache and press

<Enter>.

Array Cache Configuration Menu

Writeback Cache

Page 41: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 31 Tuesday, September 23, 2003 5:31 PM

3 Select an array from the list to which you wish to make changes. Use the

up/down arrow keys to select an array and press <Enter>.

Select Array Screen

4 Choose a Writeback Cache parameter to use for the selected array.

Writeback Cache Parmaters Screen

Use the up and down arrow keys to select and the left and right arrow keys

to change from Disabled, or choose one of the pre-determined cache

threshold sizes (1MB, 2MB, 4MB, 8MB, 16MB, 32MB, 64MB, 128MB, 256MB

or 512MB).

Writeback Cache 31

Page 42: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

32

imageRAID-MUI.book Page 32 Tuesday, September 23, 2003 5:31 PM

There are three additional options to an active Write Back Cache: Disable if a

partner controller fails or is missing, Disable if a controller battery fails,

and/or Disable if the array is in a critical state, (e.g., during a rebuild). Enable

the options for your application. For maximum data protection, it is

recommended to enable all three options.

Press <Ctrl>+<D> keys to save the changes.

5 Save the configuration changes. Highlight Yes and press <Enter>, or No to

cancel. Press any key to continue.

Save Configuration Screen

Next you will configure your hot spare drives, refer to “Assigning Hot Spare

Drives” on page 33.

Writeback Cache

Page 43: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 33 Tuesday, September 23, 2003 5:31 PM

Assigning Hot Spare Drives

The process of configuring fault tolerant arrays includes assigning drives for global or dedicated hot spares. In the event of a drive failure, the controller will use a global hot spare to replace the failed drive in any array or if a dedicated spare is assigned to the specific array, then that array will use its dedicated hot spare.

This step is accomplished through the Hot Spare Configuration menu.

1 From the Main Configuration menu, use the Up or Down Arrow keys to

select Hot Spare Configuration menu and press <Enter>.

Configuration Menu

2 To view the current configuration of hot spare drives, select View Hot Spare

Drive Configuration and press <Enter>.

Hot Spare Configuration Menu

Assigning Hot Spare Drives 33

Page 44: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

34

imageRAID-MUI.book Page 34 Tuesday, September 23, 2003 5:31 PM

3 To add or remove a spare drive, select Add or Remove Pool and Dedicated

Spare and press <Enter>.

The drive selection screen appears, use the arrow keys to highlight an

available drive to use, then press the <S> key to assign that drive as a

dedicated spare. Then continue to press the <S> key which displays the

arrays from which you can assign the dedicated spare.

To add a drive as a pool spare (global), use the arrow keys to highlight an

available drive and press the <H> key.

To remove a drive as a hot spare, highlight the subject drive and press the

<R> key, or press the <C> key to remove all drives in the enclosure that are

currently assigned as spares. After you make your selection, press the

<Ctrl>+<D> keys to continue.

Select Drive(s) for Drive Spare Screen

4 You will be prompted to save the changes. Press the <Y> key to save the

new hot spare configurations, or the <N> key to cancel. Then press any key

to continue.

5 Proceed now to “Disk LUNs” on page 47.

Assigning Hot Spare Drives

Page 45: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 35 Tuesday, September 23, 2003 5:31 PM

Delete Array

1 From the Main menu, choose Configuration Menu and press <Enter>.

Main Menu

2 From the Configuration menu, choose the Array Configuration Menu and

press <Enter>.

Configuration Menu

3 Choose Delete Array and press <Enter>.

Delete Array 35

Page 46: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

36

imageRAID-MUI.book Page 36 Tuesday, September 23, 2003 5:31 PM

Array Configuration Menu

4 Use the up/down arrow keys and select the array to delete, then press

<Enter>.

Delete Array Screen

5 Use the up/down arrow key to select Yes and press <Enter> to complete the

deletion. Select No to cancel the deletion.

Press any key to continue, you are then returned to the Array Configuration menu

where you can perform another array operation or return to another menu.

Delete Array

Page 47: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 37 Tuesday, September 23, 2003 5:31 PM

Expanding an Array

The Expand Array option allows you to expand the capacity of your existing

array by adding more drives or adding sub-arrays.

Using a RAID 5 array example, adding more drives to the array allows you to

simply increase the capacity of that array. If you add additional sub-arrays it

requires the exact number of drives to be available for the original sub-array. For

example, if you have an array composed of 4 data drives and 1 parity drive, you

must have a minimum of five drives available to be able to add at least 1

sub-array.

When you view the array configuration information, the RAID type and number

of drives are displayed. These drives are depicted as data drives plus parity

drives. In this example, it would be displayed as “4 Drives (3 +1)” which

indicates the array/

sub-array is composed of 4 drives of which 3 are data drives and 1 is a parity

drive. If you were to add 1 sub-array to this particular configuration, the resulting

display would be “8 Drives (6+2)” in which case you now have 6 data drives and

2 parity drives. Your RAID 5 array now becomes a RAID 50 array because it’s

composed of two sub-arrays, each sub-array has three data drives and one parity

drive.

If you are expanding a RAID 50 array by adding drives to the array, you must add

an equal number of drives to each sub-array.

The process of expandiing the array by adding additional sub-arrays allows for

quicker recoveries in the event of a drive failure in any one of the sub-arrays, and

the time required to rebuild the array is significantly shortened.

To add more drives to your existing arrays, refer to “Adding Additional Drives” on

page 38.

To add more sub-arrays to your existing array, refer to “Adding Additional

Sub-Arrays” on page 41.

Expanding an Array 37

Page 48: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

38

imageRAID-MUI.book Page 38 Tuesday, September 23, 2003 5:31 PM

Adding Additional Drives

1 From the Main menu, choose the Configuration Menu and press <Enter>.

Main Menu

2 From the Configuration menu, choose the Array Configuration Menu and

press <Enter>.

Configuration Menu

Adding Additional Drives

Page 49: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 39 Tuesday, September 23, 2003 5:31 PM

3 Choose Expand Array and press <Enter>.

Array Configuration Menu

4 Use the up/down arrow keys to select an array to expand then press

<Enter>.

Select Array To Expand Array Menu

5 Use the Up and Down Arrow keys to select “Add a Number of Drives to the

Array”, then press <Enter>.

Adding Additional Drives 39

Page 50: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

40

imageRAID-MUI.book Page 40 Tuesday, September 23, 2003 5:31 PM

Add Drives To Expand Array Menu

6 Use the Up and Down Arrow keys to select a drive, and press the <X> key to

mark that drive for expansion. Continue to select additional drives if

necessary, otherwise press the <Ctrl>+<D> keys to continue.

You can remove a drive selected by highlighting the drive and pressing the

<R> key, or the <C> key to remove all selected drives and start again.

Select Drives Screen

7 You will be prompted to save the changes, choose Yes and press <Enter>.

Selecting No will cancel all operations and return you to the Main menu.

Adding Additional Drives

Page 51: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 41 Tuesday, September 23, 2003 5:31 PM

8 When prompted press any key to continue. You will be returned to the Main

menu.

Adding Additional Sub-Arrays

1 From the Main menu, choose Configuration Menu and press <Enter>.

Main Menu

2 From the Configuration menu, choose the Array Configuration Menu and

press <Enter>.

Configuration Menu

Adding Additional Sub-Arrays 41

Page 52: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

42

imageRAID-MUI.book Page 42 Tuesday, September 23, 2003 5:31 PM

3 Choose Expand Array and press <Enter>.

Array Configuration Menu

4 Use the up/down arrow keys to select an array to expand then press

<Enter>.

Select Array To Expand Array Menu

5 Use the Up and Down Arrow keys to select “Add a Number of Sub-Arrays to

the Current Array”, then press <Enter>.

Adding Additional Sub-Arrays

Page 53: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 43 Tuesday, September 23, 2003 5:31 PM

Add a Number of Sub-Arrays To Expand Array Menu

6 Use the Up and Down Arrow keys to select a drive, and press the <X> key to

mark that drive for expansion. Continue to select additional drives if

necessary, otherwise press the <Ctrl>+<D> keys to continue.

You can remove a drive selected by highlighting the drive and pressing the

<R> key, or the <C> key to remove all selected drives and start again.

Select Drives Screen

Adding Additional Sub-Arrays 43

Page 54: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

44

imageRAID-MUI.book Page 44 Tuesday, September 23, 2003 5:31 PM

7 You will be prompted to save the changes, choose Yes and press <Enter>.

Selecting No will cancel all operations and return you to the Main menu.

8 When prompted press any key to continue. You are returned to the Main

menu.

Adding Additional Sub-Arrays

Page 55: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

imageRAID-MUI.book Page 45 Tuesday, September 23, 2003 5:31 PM

Trust an Array

When you create a RAID 5 or 50 array, you have the option to trust the array.

This option should only be used in environments where the user fully

understands the consequences of the function. Trust array option is provided to

allow immediate access to an array for testing application purposes only.

Trust array does not calculate parity across all drives and therefore there is no

known state on the drives. As data is received from the host parity is calculated as

normal, but it occurs on a block basis. There is no way to guarantee that parity

has been calculated across the entire drive. The parity data will be inconsistent

and so a drive failure within a trusted array will cause data loss.

1 While creating a RAID 5/50 array, after you have selected the number of

sub-arrays, you will be prompted to Initialize or Trust the array.

Initialize/Trust Array Screen

2 (Test Purposes Only) Choose to trust the array, highlight Trust Array and

press <Enter>.

3 You are prompted to save the configuration. Highlight Yes to save the

configuration and press <Enter>. Otherwise select No to cancel and return to

the Main menu.

You will see a message that the configuration is being saved. Once it has

completed the process, press any key to continue.

Trust an Array 45

Page 56: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 2 - Creating Disk Arrays

46

imageRAID-MUI.book Page 46 Tuesday, September 23, 2003 5:31 PM

Trust an Array

Page 57: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3

imageRAID-MUI.book Page 47 Tuesday, September 23, 2003 5:31 PM

Disk LUNs

Configuration

A Disk LUN (LUN) is defined as a region or combination of regions of unused

space on the array(s) which makes the LUNs available to the host operating

systems as a LUN. You may create up to 512 LUNs. After an array has been

created, this region is first marked as unassigned. One or more LUNs can be

created in this region or an existing LUNs can be expanded using this region. A

LUN can be created or expanded in 1 GB increments with a maximum total size

per LUN of 2,198 GBs. This corresponds to the SCSI 32 bit addressing limitation

of 2 TB.

NOTE: For Microsoft® Windows® NT there is a limitation of 231 LUNs. A hot fix

is available from Microsoft®; refer to Microsoft® Knowledge Base

Article - 245637.

Terminology

The following table describes the terminology relating to Disk LUNs.

Term Description

LUN Segmentation Any LUN can be expanded into any free region, so it is possible to easily add capacity at any time. There is no requirement that any additional space be contiguous. LUN Segmentation is completely transparent to the host systems.

47

Page 58: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

48

imageRAID-MUI.book Page 48 Tuesday, September 23, 2003 5:31 PM

Accessing the LUN Configuration Menu

1 From the Main menu, choose the Configuration Menu and press <Enter>.

2 From the Configuration menu, use the up/down arrows keys to select the

LUN Configuration menu and press <Enter>.

Configuration Menu - LUN Configuration Screen

LUN Availability To accommodate hosts with multiple ports and multiple host systems, you can restrict a LUN’s availability to a particular controller port. Access can be enabled or disabled for each port of each controller.

Mapped LUN Number Each LUN is presented to the host system with a unique LUN number. In certain cases (such as after deleting another LUN) it may be desirable to change the number the LUN is presented as. This can be done at any time, bearing in mind that any attached host systems may need to be rebooted or reconfigured to retain access.

Unassigned Free Space The controller keeps a map of all the space that is not assigned to any LUN. This space is available for LUN creation or expansion. Each unassigned region is individually listed.

Accessing the LUN Configuration Menu

Page 59: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 49 Tuesday, September 23, 2003 5:31 PM

The LUN Configuration menu has two menu options: one for managing LUNs

which includes utilities for viewing, creating, deleting, and managing LUNs,

and the other is for performing SAN LUN Mapping operations.

LUN Configuration Menu Screen

Viewing Unassigned Free Space

Prior to creating a disk LUN, you may wish to review the available unassigned

free space. This will help you to identify the unused regions or segments for use

during the creation of your LUNs. Normally with a first time configuration this is

not necessary, since all of the space is unassigned.

1 From the LUN Configuration menu, choose the LUN Management option and

press <Enter>.

2 Use the Up and Down Arrow keys to select View Unassigned Free Space and

press <Enter>.

Viewing Unassigned Free Space 49

Page 60: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

50

imageRAID-MUI.book Page 50 Tuesday, September 23, 2003 5:31 PM

LUN Management Menu - View Unassigned Free Space Screen

3 The free space regions are displayed, examine the free space regions and

note them for later use.

Unassigned Free Space Screen

Viewing Unassigned Free Space

Page 61: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 51 Tuesday, September 23, 2003 5:31 PM

Creating a Disk LUN

To complete the process of configuring your arrays, you will need to create one

or more LUNs. Creating a LUN from the available free space regions presents the

LUN to the host operating system as a drive.

1 From the LUN Management menu, use the up/down arrow keys to select

Create LUN and press <Enter>.

LUN Management Menu - Create LUN

2 Use the Up and Down Arrow keys to select a region you wish to use for the

LUN and press <Enter>.

Select an Unused Region Screen

Creating a Disk LUN 51

Page 62: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

52

imageRAID-MUI.book Page 52 Tuesday, September 23, 2003 5:31 PM

3 Enter the number of LUNs to create, use the Up and Down Arrow keys to

change the value to the desired number of LUNs and press <Enter>.

Select Number of LUNs to Create Screen

The number shown as the default is the maximum number of 1 GB LUNs you

can create using the selected free space region in the previous step. In this

case the free space region was 29 GB which yielded a total of 29 1 GB LUNs.

4 Enter the size of LUN to create. Use the Up and Down Arrow keys to change

the value to the desired size of the LUN and press <Enter>.

Select Size for the LUNs to Create Screen

Creating a Disk LUN

Page 63: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 53 Tuesday, September 23, 2003 5:31 PM

The default value displayed is the size of the LUN that can be created using

the number of LUNs set in the previous screen based on the unused region

space. If you are creating an even number of LUNs from an odd size value

the remaining unused space is made available as unused space from which

another separate LUN can be created. For example, if you have a fault

tolerant array with unused region of 143 GB and you create 2 LUNs from that

unused space, you will have two LUNs each with 71 GBs. After you create

the LUNs and view the unused region you will see the remaining 1 GB

available for use in another LUN.

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will return you to the LUN Management menu where

you can start again which cancels the operation.

6 When prompted press any key to continue. You are returned to the Main

menu.

This completes creating and assigning disk LUNs.

Creating a Disk LUN 53

Page 64: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

54

imageRAID-MUI.book Page 54 Tuesday, September 23, 2003 5:31 PM

Expand a LUN

1 From the LUN Management menu, use the Up and Down Arrow keys to

select Expand LUN and press <Enter>.

LUN Management Menu - Expand LUN Screen

2 Use the Up and Down Arrow keys to select a disk LUN that you wish to

expand and press <Enter>.

Select a LUN to Expand Screen

Expand a LUN

Page 65: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 55 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select an unused region that you wish

to expand the disk LUN into and press <Enter>.

Select Unused Region to Expand the LUN Screen

4 Enter the size of the additional space to expand the LUN, use the Up and

Down Arrow keys to change the value to the desired size and press <Enter>.

Select Expansion Size Screen

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Expand a LUN 55

Page 66: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

56

imageRAID-MUI.book Page 56 Tuesday, September 23, 2003 5:31 PM

Set LUN Availability

This option will make a LUN available to a controller port and determines whether

that LUN is seen by any or a specific host system attached to that controller port.

1 From the LUN Management menu, use the Up and Down Arrow keys to

select Set LUN Availability and press <Enter>.

LUN Management Menu - Set LUN Availability Screen

2 Use the Up and Down Arrow keys to select a LUN that you wish to map to

another LUN number and press <Enter>.

Select a LUN for Availability Screen

Set LUN Availability

Page 67: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 57 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select a controller port. Pressing

<Enter> will change the property from Enable to Disable.

Select a Controller Port to Modify Screen

4 Choose the other controller port if you wish to change whether that LUN is

available on that port as well. If the setting is satisfactory as is, skip this step.

5 Press the <Ctrl> + <D> keys to open the save the changes screen.

6 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

7 When prompted press any key to continue. You are returned to the Main

menu.

Set LUN Availability 57

Page 68: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

58

imageRAID-MUI.book Page 58 Tuesday, September 23, 2003 5:31 PM

Delete a LUN

This process will remove a LUN that was previously created.

1 From the LUN Management menu, use the Up and Down Arrow keys to

select Delete LUN and press <Enter>.

LUN Management Menu - Delete LUN Screen

2 Use the Up and Down Arrow keys to select a LUN which you intend to

delete and press <Enter>.

Select a LUN to Delete Screen

Delete a LUN

Page 69: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 59 Tuesday, September 23, 2003 5:31 PM

3 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

4 When prompted press any key to continue. You are returned to the Main

menu.

Delete a LUN 59

Page 70: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

60

imageRAID-MUI.book Page 60 Tuesday, September 23, 2003 5:31 PM

Modify Mapped LUN

This option allows you to change the assigned LUN number after the LUN has

been created.

1 From the LUN Management menu, use the Up and Down Arrow keys to

select Modify Mapped LUN Number and press <Enter>.

LUN Management Menu - Modify LUN Number Screen

2 Use the Up and Down Arrow keys to select a LUN which you intend to

change the mapped LUN number and press <Enter>.

Select a LUN to Modify Screen

Modify Mapped LUN

Page 71: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

imageRAID-MUI.book Page 61 Tuesday, September 23, 2003 5:31 PM

3 Enter the new number of the LUN, use the Up and Down Arrow keys to

change the LUN number to the new LUN number and press the <Enter>.

Select New LUN Number for the LUN Screen

4 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

5 When prompted press any key to continue. You are returned to the Main

menu.

Modify Mapped LUN 61

Page 72: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 3 - Disk LUNs

62

imageRAID-MUI.book Page 62 Tuesday, September 23, 2003 5:31 PM

Modify Mapped LUN

Page 73: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4

imageRAID-MUI.book Page 63 Tuesday, September 23, 2003 5:31 PM

SAN LUN Mapping

When attaching multiple host systems in a SAN environment, it may be necessary

to more precisely control which hosts have access to which LUNs. In addition to

controlling LUN availability on a controller port by port basis, it is also possible to

further restrict access to a specific host system or single adapter in a host system.

Up to 512 SAN LUN Mappings are supported.

Terminology

The following table describes the terminology relating to SAN LUNs.

Term Description

Node Name This is an eight byte hexadecimal number, uniquely identifying a single host system. It incorporates the World Wide Name and two additional bytes which are used to specify the format. In a system with multiple FC ports, all adapters will typically use the same Node Name, but unique Port Names.

Port Name This is an eight byte hexadecimal number, uniquely identifying a single host port. It incorporates the World Wide Name and two additional bytes which are used to specify the format and indicate the port number.

Mapping Name A 32 character name that can be used to help identify the host system.

Exclusive Access A LUN is presented to one and only one host system. It is not available to any other host systems.

Read/Write Access A LUN will allow both reads and write operations.

Read Only Access A LUN will not allow writes.

Mapped LUN Number This is the LUN number that a specific LUN responds to when accessed by a host. It is not necessary for this to bear any relation to the LUN number.

Mapping Availability Which controller ports the mapping is valid for.

63

Page 74: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

64

imageRAID-MUI.book Page 64 Tuesday, September 23, 2003 5:31 PM

Accessing the SAN LUN Mapping Configuration Menu

1 From the Main menu, choose the Configuration Menu and press <Enter>.

2 From the Configuration menu, use the Up and Down Arrows keys to select

the LUN Configuration menu and press <Enter>.

Configuration Menu - LUN Configuration Screen

3 From the LUN Configuration menu, use the Up and Down Arrows keys to

select the SAN LUN Mapping menu and press <Enter>.

LUN Configuration Menu Screen

Accessing the SAN LUN Mapping Configuration Menu

Page 75: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 65 Tuesday, September 23, 2003 5:31 PM

The SAN LUN Mapping Configuration menu provides the options for

viewing, creating, deleting, and managing SAN LUNs, and for viewing the

host systems attached to the storage network.

Viewing SAN LUN Mappings

To view existing SAN LUN Mappings, choose this option.

1 From the Main menu, choose the Configuration Menu and press <Enter>.

2 From the Configuration menu, use the Up and Down Arrows keys to select

the LUN Configuration menu and press <Enter>.

3 From the LUN Configuration menu, use the Up and Down Arrows keys to

select the SAN LUN Mapping menu and press <Enter>.

4 Use the Up and Down Arrow keys to select View SAN LUN Mappings and

press <Enter>.

View SAN LUN Mapping Screen

In the example above, there are two mappings created. They have an identical

node name but different port names, indicating they are both in the same host

system. The port name is used for the mapping, and access is only allowed on Port

0 of the controllers. Each host HBA port can access one controller LUN, exclusively.

Viewing SAN LUN Mappings 65

Page 76: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

66

imageRAID-MUI.book Page 66 Tuesday, September 23, 2003 5:31 PM

Creating a SAN LUN Mapping

1 From the SAN LUN Mapping Menu, use the Up and Down Arrow keys to

select Create SAN LUN Mapping and press <Enter>.

SAN LUN Mapping Menu - Create Screen

2 Enter a unique name for this mapping and press <Enter>.

You can use from 1 to 32 characters for the mapping name.

Enter SAN LUN Mapping Name Screen

3 In the next screen you will choose to enter the Node/Port name information

manually or select from the discovered list of hosts.

Creating a SAN LUN Mapping

Page 77: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 67 Tuesday, September 23, 2003 5:31 PM

Selecting a Node/Port Name Method Screen

To select from the list of connected hosts

a Use the Up and Down Arrow keys to select a host HBA Port and press

<Enter>.

Selecting HBA Port Name Screen

b You are prompted with a question if you wish to use the HBA’s node

name. Select Yes to use this node name or no to use the port name.

A mapping can use either the host’s HBA node name or port name.

Using the Node Name allows for multiple adapters in the same host to

use this same mapping, even though they have different Port names.

Creating a SAN LUN Mapping 67

Page 78: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

68

imageRAID-MUI.book Page 68 Tuesday, September 23, 2003 5:31 PM

Using the HBA Port Name is more restrictive, allowing only this particular

HBA Port Name to use this mapping.

Use Node Name Screen

c Select the port or ports where the SAN LUN Mapping will be available or

seen. Use the Up and Down Arrow keys to select your choice and press

<Enter>.

SAN LUN Mapping Availability Screen

Creating a SAN LUN Mapping

Page 79: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 69 Tuesday, September 23, 2003 5:31 PM

SAN LUN Mapping Configuration Screen

d Set the parameters for the SAN LUN Mapping.

Use the <Enter> key to toggle the type of access desired (shared, shared

read only, exclusive, or NA. Use the <Left> or <Right> arrow keys to

change the LUN number and the <Up> or <Down> arrow keys to cycle

through the LUNs.

If a LUN is already part of another mapping, and is defined as Exclusive,

it will not be available here for selection. If the LUN was mapped as

Share or Shared Read Only, it will be available.

NOTE: Microsoft® Windows NT®, Microsoft® Windows® 2000 or

Microsoft® Windows® 2003 does not support a Read Only file

system.

e You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the

Main menu.

f When prompted press any key to continue. You are returned to the Main

menu. (Refer to the following page for manual setup procedures.)

Creating a SAN LUN Mapping 69

Page 80: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

70

imageRAID-MUI.book Page 70 Tuesday, September 23, 2003 5:31 PM

OR To Manually Enter a Node/Port Name:

a Use the Up and Down Arrow keys to select Enter Manually and press

<Enter>.

Selecting a Node/Port Name Method Screen

b Type in the space provided the host HBA node name and press <Enter>.

It will be necessary to enter both the node name followed by the port

name. These names are 16 characters and is an 8 byte number in

hexadecimal format. (You should be able to get this information from the

option “View Connected Hosts menu.”)

Enter Node Name Screen

Creating a SAN LUN Mapping

Page 81: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 71 Tuesday, September 23, 2003 5:31 PM

c Type in the space provided the host HBA port name and press <Enter>.

Enter Port Name Screen

d You are prompted to use the node name. Select Yes to use this node

name or no to use the port name.

A mapping can use either the host’s HBA node name or port name.

Using the Node Name allows for multiple adapters in the same host to

use this same mapping, even though they have different Port names.

Use Node Name Screen

Creating a SAN LUN Mapping 71

Page 82: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

72

imageRAID-MUI.book Page 72 Tuesday, September 23, 2003 5:31 PM

Using the Port Name is more restrictive, allowing only this particular Port

Name to use this mapping.

e Select the port or ports where the SAN LUN Mapping will be available or

seen. Use the Up and Down Arrow keys to select your choice and press

<Enter>.

SAN LUN Mapping Availability Screen

f Set the parameters for the SAN LUN Mapping.

SAN LUN Mapping Configuration Screen

Creating a SAN LUN Mapping

Page 83: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 73 Tuesday, September 23, 2003 5:31 PM

Use the <Enter> key to toggle the type of access desired (shared, shared

read only, exclusive, or NA. Use the <Left> or <Right> arrow keys to

change the LUN number and the <Up> or <Down> arrow keys to cycle

through the LUNs.

If a LUN is already part of another mapping, and is defined as Exclusive,

it will not be available here for selection. If the LUN was mapped as

Share or Shared Read Only, it will be available. Note that Microsoft®

Windows NT®, Microsoft® Windows® 2000 or Microsoft® Windows®

2003 does not support a Read Only file system.

g You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the

Main menu.

h When prompted press any key to continue. You are returned to the Main

menu.

Creating a SAN LUN Mapping 73

Page 84: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

74

imageRAID-MUI.book Page 74 Tuesday, September 23, 2003 5:31 PM

Delete SAN LUN Mapping

This option allows you to delete a SAN LUN Mapping.

1 From the SAN LUN Mapping Menu, use the Up and Down Arrow keys to

select Delete SAN LUN Mapping and press <Enter>.

SAN LUN Mapping Configuration Menu Screen

2 Use the Up and Down Arrow keys to select a SAN LUN Mapping to be

deleted and press <Enter>.

Delete SAN LUN Mapping Screen

Delete SAN LUN Mapping

Page 85: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 75 Tuesday, September 23, 2003 5:31 PM

NOTE: SAN LUN Mappings can be deleted in any order without affecting

the other mappings.

3 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

4 When prompted press any key to continue. You are returned to the Main

menu.

Modify SAN LUN Mapping

It is sometimes necessary to modify some or all of the parameters of a SAN LUN

Mapping. You may change the Mapping Name, Node Name, Port Name, whether

to use the HBA node or HBA port name and the controller port availability of the

mapping.

This may be necessary if, for example, a host system has an adapter failure and a

new adapter with different Node and Port names is installed.

1 From the SAN LUN Mapping Menu, use the Up and Down Arrow keys to

select Modify SAN LUN Mapping and press <Enter>.

SAN LUN Mapping Configuration Menu

Modify SAN LUN Mapping 75

Page 86: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

76

imageRAID-MUI.book Page 76 Tuesday, September 23, 2003 5:31 PM

2 Use the Up and Down Arrow keys to select a SAN LUN Mapping to be

modified and press <Enter>.

Modify SAN LUN Mapping Screen

3 Enter a new SAN LUN Mapping name and press <Enter>, or if you wish to

leave it unchanged and move to the next screen just press <Enter>.

Modify SAN LUN Mapping Name Screen

Modify SAN LUN Mapping

Page 87: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 77 Tuesday, September 23, 2003 5:31 PM

4 Enter a new host HBA node name and press <Enter>, or if you wish to leave

it unchanged and move to the next screen just press <Enter>.

The node name is 16 characters and is an 8 byte number in hexadecimal

format. (You should be able to get this information from the option “View

Connected Hosts menu.”)

Modify Node Name Screen

5 Enter a new host HBA port name and press <Enter>, or just press <Enter> to

skip to the next screen.

Modify Port Name Screen

6 You are prompted to use the node name. Select Yes to use this node name or

no to use the port name.

Modify SAN LUN Mapping 77

Page 88: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

78

imageRAID-MUI.book Page 78 Tuesday, September 23, 2003 5:31 PM

A mapping can use either the host’s HBA node name or port name. Using the

Node Name allows for multiple adapters in the same host to use this same

mapping, even though they have different Port names.

Modify Node Name Screen

Using the Port Name is more restrictive, allowing only this particular Port

Name to use this mapping. Note that this is irrespective of what Controller

Port the mapping is later restricted to.

7 Modify the port or ports where the SAN LUN Mapping will be available or

seen. Use the Up and Down Arrow keys to select your choice and press

<Enter>, or if you wish to leave it unchanged and move to the next screen

just press <Enter>.

Modify SAN LUN Mapping Availability Screen

Modify SAN LUN Mapping

Page 89: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 79 Tuesday, September 23, 2003 5:31 PM

Modify SAN LUN Mapping Configuration Screen

8 Change the parameters for the SAN LUN Mapping.

Use the <Enter> key to toggle the type of access desired (shared, shared read

only, exclusive, or NA. Use the <Left> or <Right> arrow keys to change the

LUN number and the <Up> or <Down> arrow keys to cycle through the

LUNs.

If a LUN is already part of another mapping, and is defined as Exclusive, it

will not be available here for selection. If the LUN was mapped as Share or

Shared Read Only, it will be available. Note that Microsoft® Windows NT®,

Microsoft® Windows® 2000 or Microsoft® Windows® 2003 does not support

a Read Only file system.

9 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

10 When prompted press any key to continue. You are returned to the Main

menu.

Modify SAN LUN Mapping 79

Page 90: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

80

imageRAID-MUI.book Page 80 Tuesday, September 23, 2003 5:31 PM

Viewing Connected Hosts

Choose this option to view all connected host HBA ports.

1 From the SAN LUN Mapping Configuration Menu, type <5> for the View

Connected Host menu and press <Enter>.

SAN LUN Mapping Configuration Menu

The following screen is displayed. In this example one connected host HBA

port is shown.

View Logged-In Hosts Screen

Viewing Connected Hosts

Page 91: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

imageRAID-MUI.book Page 81 Tuesday, September 23, 2003 5:31 PM

The table below provides an explanation of each of the fields shown in the

display.

Field Description

No. Host number assigned by the controller. This is used when creating a SAN LUN Mapping and selecting a host from the list.

Node Name This is the Host HBA Port’s node name.

Port Name This is the Host HBA Port’s port name.

ID-xy ID used by this host for Controller x Port y. (L) indicates Arbitrated Loop, and (F) indicates fabric connect.

Viewing Connected Hosts 81

Page 92: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 4 - SAN LUN Mapping

82

imageRAID-MUI.book Page 82 Tuesday, September 23, 2003 5:31 PM

Viewing Connected Hosts

Page 93: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5

imageRAID-MUI.book Page 83 Tuesday, September 23, 2003 5:31 PM

Advanced Configuration and Management

In this chapter we will cover the advanced configuration and management

options, such as setting and fine tuning rebuild parameters, configuring hot

spares, setting controller specific hardware parameters, viewing controller

information, and clearing the configuration.

Rebuild Parameters

The Rebuild Parameters menu option lets you enable or disable automatic rebuild

operations, set the rebuild priority, and configure the controller for the auto hot

spare feature.

Enable/Disable Auto Rebuild

Whenever a hot spare is created whether it is a pool or dedicated spare (for the

specific array), the automatic rebuild feature is enabled. However, there may be

occasions where it is necessary to manually enable or disable this option.

When enabled, auto regeneration will begin the rebuild cycle when a fault

tolerant array is configured and a hot spare drive is available.

1 From the Main menu select Configuration Menu and press <Enter>.

2 From the Configuration menu select Rebuild Parameters menu and press

<Enter>.

83

Page 94: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

84

imageRAID-MUI.book Page 84 Tuesday, September 23, 2003 5:31 PM

Configuration Menu - Rebuild Parameters Screen

3 From the Rebuild Parameters menu select the Auto Rebuild and Set Priority

option and press <Enter>.

Rebuild Parameters Menu - Auto Rebuild Screen

Enable/Disable Auto Rebuild

Page 95: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 85 Tuesday, September 23, 2003 5:31 PM

4 At the “Auto Rebuild and Set Priority” menu you have the option to toggle

the automatic rebuild parameter, or set the percent of processor time

allocated to a rebuild operation.

Rebuild Parameters Screen

a Press the <Enter> key to Enable or Disable the “Auto Rebuild” option.

b Use the Up and Down Arrow keys to change the rebuild priority value.

The values range from 10% through 90%. The higher the value the more

processor time is allocated to the rebuild operation.

5 Press the <Ctrl> + <D> keys to save the changes or press <Esc> for the

previous menu to cancel.

Auto Hot Spare

This feature allows the user to configure the controller to automatically start a

rebuild operation when a replacement drive is inserted into the drive slot of the

removed failed drive member. This feature only applies when a dedicated or

pool spare has not been assigned.

1 From the Main menu select Configuration Menu and press <Enter>.

2 From the Configuration menu select Rebuild Parameters menu and press

<Enter>.

Auto Hot Spare 85

Page 96: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

86

imageRAID-MUI.book Page 86 Tuesday, September 23, 2003 5:31 PM

Configuration Menu - Rebuild Parameters Screen

3 From the Rebuild Parameters menu select the Auto Hot Spare option and

press <Enter>.

Rebuild Parameters Menu - Auto Hot Spare Screen

Auto Hot Spare

Page 97: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 87 Tuesday, September 23, 2003 5:31 PM

4 Press the <Enter> key to toggle between Enable or Disable of the “Auto Hot

Spare” option.

Auto Hot Spare Screen

5 Press the <Ctrl> + <D> keys to save the changes or press <Esc> for the

previous menu to cancel.

Hot Spare Configuration

The process of configuring fault tolerant arrays includes assigning drives for

global or dedicated hot spares. In the event of a drive failure that is a member of

a fault tolerant array, the controller will use an assigned global hot spare to

replace the failed drive in any array, or if a dedicated spare is assigned to the

specific array, then that array will use its dedicated hot spare to replace the failed

drive member.

Viewing the List of Hot Spare Drives

1 From the Main menu, select Configuration Menu and press <Enter>.

2 Use the Up and Down arrow keys to highlight Hot Spare Configuration and

press <Enter>.

Hot Spare Configuration 87

Page 98: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

88

imageRAID-MUI.book Page 88 Tuesday, September 23, 2003 5:31 PM

Configuration Menu - Hot Spare Configuration Selected Screen

3 Highlight “View Hot Spare Drive Configuration” and press <Enter>.

Hot Spare Configuration Menu - View Hot Spare Drive Screen

Viewing the List of Hot Spare Drives

Page 99: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 89 Tuesday, September 23, 2003 5:31 PM

Adding or Removing Hot Spare Drives

1 From the Main menu, select Configuration Menu and press <Enter>.

2 Use the Up and Down arrow keys to highlight Hot Spare Configuration and

press <Enter>.

Configuration Menu - Hot Spare Configuration Selected Screen

3 Highlight “Add or Remove Global and Dedicate Spares” and press <Enter>.

Hot Spare Configuration Menu - Add or Remove Global and Dedicated Spare Screen

Adding or Removing Hot Spare Drives 89

Page 100: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

90

imageRAID-MUI.book Page 90 Tuesday, September 23, 2003 5:31 PM

The drive selection screen appears, use the arrow keys to highlight an

available drive to use:

To add a dedicated spare, press the <S> key to assign that drive as a

dedicated spare. Then continue to press the <S> key which will display the

arrays from which you can assign the dedicated spare.

To add a drive as a global spare, use the arrow keys to highlight an available

drive and press the <H> key.

To remove a drive as a hot spare, highlight the subject drive and press the

<R> key, or press the <C> key to remove all drives in the enclosure that are

currently assigned as spares. After you make your selection, press the

<Ctrl>+<D> keys to continue.

Select Drive(s) for Drive Spare Screen

4 You will be prompted to save the changes. Press the <Y> key to save the

new hot spare configurations, or the <N> key to cancel. Then press any key

to continue.

5 If you are creating hot spare drives as part of your initial configuration and

setup, proceed now to “Disk LUNs” on page 47.

Adding or Removing Hot Spare Drives

Page 101: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 91 Tuesday, September 23, 2003 5:31 PM

Hardware Configuration Settings

The hardware configuration menu provides the options to set the Controller LUN,

configure the host loop Port ID address setting, set the node name for the host

port, configure the port connection options, set the host port data rate, and

configure the Controller’s RS-232 port BAUD rate.

Controller LUN

This option sets the logical unit number (LUN) that StorView uses to communicate

with the RAID Controller(s). Changing this parameter can alleviate a potential

performance issue which is seen as a significant degradation in performance when

relatively high I/O activity is ongoing, and a “Disk” LUN and Controller LUN are

using the same logical unit number. The values are: Disabled, and 0 - 511, with

LUN 0 being the default.

Normally, the first “Disk” LUN you create will automatically be assigned LUN 1,

because the controller processor, by default, is 0 for the Controller logical unit

number. If your “Disk” LUN needs to be at LUN 0, then you would change the

Controller LUN parameter to another LUN that is not being used by another “Disk”

LUN. The “Not Mapped” selection is used when the controller is not required to be

addressed as an independent device. When set to “Not Mapped,” StorView will

use the first available LUN which should be at LUN 0. See “Controller LUN” on

page 91. If you need to change this parameter, make the change after you have

created your arrays, otherwise you will not be able to save the change nor see the

LUN 0 selection in the Create LUN window. This performance issue could also

occur if you perform a LUN Map to your HBA or HBA Port and assign the

mapping to the Controller LUN.

1 From the Main menu, select Configuration Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Controller LUN and press

<Enter>.

Hardware Configuration Settings 91

Page 102: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

92

imageRAID-MUI.book Page 92 Tuesday, September 23, 2003 5:31 PM

Hardware Configuration Menu Screen

3 Use the Up and Down Arrow keys to change the LUN number, or press

<Enter> to “Disable.”

If you select a LUN number that is used by another device, the word

“Conflict” will appear next to the LUN number.

Controller LUN Screen

Controller LUN

Page 103: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 93 Tuesday, September 23, 2003 5:31 PM

4 Press <Ctrl>+<D> to exit this screen and save the changes, or press <Esc> to

return to the previous menu.

5 You will be prompted to save the changes, choose Yes and press <Enter>.

Selecting No will cancel all operations and return you to the Main menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Port ID Settings

The Port ID settings provide you the option to set the hard address ID for the

host loop. You can use IDs from 0 - 125, or set the ID for soft addressing.

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu Screen

2 Use the Up and Down Arrow keys to select Port ID Settings and press

<Enter>.

Port ID Settings 93

Page 104: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

94

imageRAID-MUI.book Page 94 Tuesday, September 23, 2003 5:31 PM

Hardware Configuration Menu Screen

3 Use the Up and Down Arrow keys to select a controller host port you wish to

change, then use the Left and Right Arrow keys to change the hard address.

Press the <Enter> key to change the value to “Disabled” which allows for soft

addressing. The default IDs for Port 0 is ID 4 and Port 1 is ID 5.

NOTE: Hard addresses can only be changed when there is a RAID

configuration present.

Port ID Settings Menu Screen

Port ID Settings

Page 105: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 95 Tuesday, September 23, 2003 5:31 PM

4 Press <Ctrl>+<D> to exit this screen and save the changes. Press <Esc> to

cancel and return to the previous menu.

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Controller Port Different Node Name

This option will allow the controller to report a different Configuration WWN for

Port 0 and Port 1 (H0 and H1 connectors on the Host I/O cards respectively).

Normally, when disabled a host connected to either port will see the same

Configuration WWN. When enabled, you will see a slightly different WWN for

each port but the same Configuration name. This option is useful to users who

are connecting the storage to a switch employing a fabric topology where the

same WWN is not tolerated.

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu Screen

Controller Port Different Node Name 95

Page 106: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

96

imageRAID-MUI.book Page 96 Tuesday, September 23, 2003 5:31 PM

2 Use the Up and Down Arrow keys to select Host Port Different Node Name

and press <Enter>.

Hardware Configuration Menu Screen

3 The current setting is displayed. If it is “Disabled” press the <Enter> key to

change the value to “Enabled.” Disabled is the default setting.

Controller Port Different Node Name Screen

4 Press <Ctrl>+<D> to exit this screen and save the changes. Press <Esc> to

cancel and return to the previous menu.

Controller Port Different Node Name

Page 107: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 97 Tuesday, September 23, 2003 5:31 PM

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Controller Port Connection Options

This option sets the topology of the controller port. The Automatic setting should

be valid for most environments, where it will attempt to use Loop Only first then

Point to Point, and it attempts to match the setting of the Host HBA. For custom

settings, if you are connecting to a FL_Port switch or a NL_Port HBA, then select

“Loop Only.” If you are connecting to a F_Port switch or N_Port HBA, then

choose Point to Point. The custom settings should match the Host HBA BIOS

setting.

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu Screen

2 Use the Up and Down Arrow keys to select Host Port Connection Options

and press <Enter>.

Controller Port Connection Options 97

Page 108: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

98

imageRAID-MUI.book Page 98 Tuesday, September 23, 2003 5:31 PM

Hardware Configuration Menu Screen

3 Use the up and down arrow keys to choose a controller port and press

<Enter>.

Select Controller Port Options Screen

4 Use the up and down arrow keys to select either Automatic, Point to Point

Only, or Loop Only and press <Enter>.

Controller Port Connection Options

Page 109: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 99 Tuesday, September 23, 2003 5:31 PM

Controller Port Connection Options Screen

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Controller Port Data Rate

This option allows the user to set the data transfer rate of the controller ports.

The Automatic setting for most configurations will suffice. For custom settings, if

you choose 1GB or 2GB and override the automatic setting, be sure that this

software setting must match the hardware switch setting on the Host I/O card.

1 From the Main menu, select Configuration Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Host Port Connection Options

and press <Enter>.

Controller Port Data Rate 99

Page 110: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

100

imageRAID-MUI.book Page 100 Tuesday, September 23, 2003 5:31 PM

Hardware Configuration Menu Screen

3 Use the up and down arrow keys to choose a controller port and press

<Enter>.

Select Controller Host Port Data Rate Screen

4 Use the up and down arrow keys to select either Automatic, 1 Gb/sec, or

2 Gb/sec and press <Enter>.

Controller Port Data Rate

Page 111: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 101 Tuesday, September 23, 2003 5:31 PM

Host Port Data Rate Options Screen

5 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Controller Port Data Rate 101

Page 112: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

102

imageRAID-MUI.book Page 102 Tuesday, September 23, 2003 5:31 PM

RS-232 Settings

The RS-232 Settings option provides you with the option to set the BAUD rate for

the controller’s RS-232 port.

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu Screen

2 Use the Up and Down Arrow keys to select RS-232 Settings and press

<Enter>.

Hardware Configuration Menu Screen

RS-232 Settings

Page 113: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 103 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select a BAUD rate for the controller

RS-232 port and press <Enter>. The default and recommended setting is

115,200.

RS-232 Settings Baud Rate Selection Screen

4 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

5 When prompted press any key to continue. You are returned to the Main menu.

RS-232 Settings 103

Page 114: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

104

imageRAID-MUI.book Page 104 Tuesday, September 23, 2003 5:31 PM

Viewing Controller Information

This option provides the ability to view detailed information on the imageRAID

Controller, such as: Controller WWN, Configuration WWN and Name, Firmware,

run-time data, loop data, and onboard temperature and voltage information.

1 From the Main menu select Controller Information Menu and press <Enter>.

Main Menu - Controller Information Screen

2 From the Controller Information menu, use the Up and Down Arrow keys to

select a Controller and press <Enter>.

Controller Selection Menu Screen

Viewing Controller Information

Page 115: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 105 Tuesday, September 23, 2003 5:31 PM

3 Use the <U> key and <D> key to scroll up and down through the controller

information displayed.

If you wis.h to capture the information, press the <P> key to dump the data

to a text file.

Controller Selection Menu Screen

4 Press <Esc> to return to the previous menu.

Viewing Controller Information 105

Page 116: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

106

imageRAID-MUI.book Page 106 Tuesday, September 23, 2003 5:31 PM

Clearing the Configuration

1 From the Main menu, select Configuration Menu and press <Enter>.

Main Menu Screen

2 Use the Up and Down Arrow keys to select Clear Configuration and press

<Enter>.

Configuration Menu - Clear Configuration Screen

Clearing the Configuration

Page 117: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

imageRAID-MUI.book Page 107 Tuesday, September 23, 2003 5:31 PM

CAUTION: There is no further warning, clearing the configuration will erase all

data.

3 Press the <Y> key to continue and clear all configuration information.

Press the <N> key to cancel this operation

Clear Configuration Screen

4 Press <Esc> to return to the Main menu.

Clearing the Configuration 107

Page 118: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 5 - Advanced Configuration and Management

108

imageRAID-MUI.book Page 108 Tuesday, September 23, 2003 5:31 PM

UPS Configuration

At this time, the UPS Configuration feature is not implemented. This option will

be supported in a future release.

UPS Configuration

Page 119: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6

imageRAID-MUI.book Page 109 Tuesday, September 23, 2003 5:31 PM

Additional Configuration

In this chapter you will find information about changing controller options such

as, the Configuration Name, Configuration WWN, background processes, and

setting the Single Controller Mode for Simplex controller operations.

Modify Configuration Name

1 From the Main menu select Configuration Menu and press <Enter>.

2 From the Configuration menu select Additional Configuration menu and

press <Enter>.

Configuration Menu - Additional Configuration Screen

109

Page 120: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

110

imageRAID-MUI.book Page 110 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select Modify Configuration Name and

press <Enter>.

Additional Configuration Menu - Modify Configuration Name

4 Use the <Back Space> key to delete the existing Configuration Name

displayed, then type in a new name for your controller’s Configuration and

press <Enter> to continue.

You may use up to 64 ASCII characters for the name.

Configuration Name Screen

Modify Configuration Name

Page 121: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

imageRAID-MUI.book Page 111 Tuesday, September 23, 2003 5:31 PM

5 You will be prompted to save the Configuration, choose Yes and press <Enter>.

Selecting No will cancel all operations and return you to the Main menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

Modify Configuration WWN

When the controllers are manufactured, every controller is given a unique World

Wide Name (WWN). When a configuration is created for the first time, the WWN

for this configuration will be the WWN of one of the controllers present at that

time. Afterwards, both controllers will always use this Configuration WWN for

identification on the controller host loops. This application of using the same

Configuration WWN is to facilitate failover/failback. In the event that one or both

controllers are changed, the new controller’s will continue to use the

Configuration WWN initially assigned. This process means that there is no need

to reconfigure the controllers after a failure, they can just be plugged in without

affecting the configuration.

There are a few instances where you may need to modify the Configuration WWN:

If a controller that was used in one enclosure is moved to another enclosure

for whatever reason, and its WWN was used to create the Configurations in

both systems, this would cause both systems to report the same WWN. This

is not permitted. In that case, it would be necessary to change the original

enclosure’s Configuration WWN to use one of its controller’s WWN. This is

achieved by changing the “Modify Configuration WWN” option. It may also

be necessary to change some host parameters too, depending on how the

host systems access the controller. If the host expects to see a particular

WWN, then this parameter needs to be changed on the host as well.

Another instance is where an enclosure is pre-configured for the customer,

and for whatever reason the actual shipping controllers were not used in the

setup. The Configuration will have been setup using another controller

WWN. The controller installed does not have the same WWN of the

controller that created the configuration. This generally happens when the

manufacturer or distributors are pre-configuring systems before shipping. In

either case, the Configuration WWN will need to be changed to match the

installed controller WWN.

Modify Configuration WWN 111

Page 122: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

112

imageRAID-MUI.book Page 112 Tuesday, September 23, 2003 5:31 PM

1 From the Main menu select Configuration Menu and press <Enter>.

2 From the Configuration menu select Additional Configuration menu and

press <Enter>.

Configuration Menu - Additional Configuration Screen

3 Use the Up and Down Arrow keys to select Modify Configuration WWN and

press <Enter>.

Additional Configuration Menu - Modify Configuration WWN

Modify Configuration WWN

Page 123: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

imageRAID-MUI.book Page 113 Tuesday, September 23, 2003 5:31 PM

4 Use the Up and Down Arrow keys to select a controller’s WWN for use as the

Configuration WWN and press <Enter> to continue.

Modify Configuration WWN Screen

5 You will be prompted to save the Configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

6 When prompted press any key to continue. You are returned to the Main

menu.

NOTE: The controllers must be rebooted after changing this parameter. You will

be instructed to reset each controller separately for Active-Active

configurations. With Active-Active configuration this allows continuous

operations with only minor system degradation during the reboot. When

the first controller is reset, the partner controller fails over until the first

controller is brought back online. Then when the second controller is

reset it fails over to the first controller and back again to normal

operations once the second controller is back online.

a From the Main menu use the Up and Down Arrow keys to select the

Diagnostics menu and press <Enter>.

b Use the Up and Down Arrow keys to select Reset Controller and press

<Enter>.

Modify Configuration WWN 113

Page 124: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

114

imageRAID-MUI.book Page 114 Tuesday, September 23, 2003 5:31 PM

Diagnostics - Reset Controller Screen

c Use the Up and Down Arrow keys to select a controller to reboot and

press <Enter>.

Reset Controller Screen

d Select Yes to reboot the controller and press <Enter>.

e Standby while the controller reset takes place.

f If this is an Active-Active configuration, repeat steps: a) through e) for

the partner controller.

Modify Configuration WWN

Page 125: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

imageRAID-MUI.book Page 115 Tuesday, September 23, 2003 5:31 PM

Setting Single Controller Mode

In Simplex configurations where only one controller is present, you need to

change a setting to disable the controller from constantly checking for the partner

controller. This prevents unnecessary warnings or events about either a failed or

missing controller.

1 From the Main menu select Configuration Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Additional Configuration menu

and press <Enter>.

Configuration Menu - Additional Configuration Screen

3 Use the Up and Down Arrow keys to select Set Single Controller Mode and

press <Enter>.

Additional Configuration Menu - Set Single Controller Mode

Setting Single Controller Mode 115

Page 126: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

116

imageRAID-MUI.book Page 116 Tuesday, September 23, 2003 5:31 PM

4 Press <Enter> to toggle the Single Controller Mode to “Enable” or “Disable.”

Enabling Single Controller Mode will cause the controller to not light its’

Partner Fail LED when only one controller is present, and prevents

unnecessary errors and events from being reported.

Set Single Controller Mode Screen

5 Press <Ctrl>+<D> to continue and save the changes.

6 You will be prompted to save the Configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

7 When prompted press any key to continue. You are returned to the Main

menu.

Background Verification

This option, when enabled will automatically verify the media of all drives in the

background. If a media error is detected, the controller can automatically re-write

the data, providing that the array is in a fault tolerant mode.

1 From the Main menu select Configuration Menu and press <Enter>.

2 Use the Up and Down Arrow key to select Additional Configuration menu

and press <Enter>.

Background Verification

Page 127: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

imageRAID-MUI.book Page 117 Tuesday, September 23, 2003 5:31 PM

Configuration Menu - Additional Configuration Screen

3 Use the Up and Down Arrow keys to select Background Verification and

press <Enter>.

Additional Configuration Menu - Background Verification Screen

4 Press <Enter> to toggle between “Enabled” or “Disabled” Background

Verification.

Enabling this option turns on the ability to perform the background media

verification.

Background Verification 117

Page 128: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

118

imageRAID-MUI.book Page 118 Tuesday, September 23, 2003 5:31 PM

Background Verification Screen

5 Press <Ctrl>+<D> to continue and save the changes.

6 You will be prompted to save the Configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

7 When prompted press any key to continue. You are returned to the Main

menu.

Controller SES

This option allows the user to turn on or off whether SES Events are included in

the Event logs. SES Events are those which pertain to the enclosure components

such as cooling fan status, power supply status, I/O card status, etc.

1 From the Main menu select Configuration Menu and press <Enter>.

2 Use the Up and Down Arrow key to select Additional Configuration menu

and press <Enter>.

Controller SES

Page 129: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

imageRAID-MUI.book Page 119 Tuesday, September 23, 2003 5:31 PM

Configuration Menu - Additional Configuration Screen

3 Use the Up and Down Arrow keys to select Controller SES and press <Enter>.

Additional Configuration Menu - Controller SES Screen

4 Press <Enter> to toggle between “Enabled” or “Disabled” SES enclosure

events.

Enabling this option turns on the ability to include SES Events in the Events

Log file.

Controller SES 119

Page 130: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 6 - Additional Configuration

120

imageRAID-MUI.book Page 120 Tuesday, September 23, 2003 5:31 PM

Controller SES Screen

5 Press <Ctrl>+<D> to continue and save the changes.

6 You will be prompted to save the configuration, choose Yes and press

<Enter>. Selecting No will cancel all operations and return you to the Main

menu.

7 When prompted press any key to continue. You are returned to the Main

menu.

Controller SES

Page 131: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7

imageRAID-MUI.book Page 121 Tuesday, September 23, 2003 5:31 PM

Statistics

The imageRAID Controller monitors all incoming commands and calculates

various statistics. These statistics are then reported to the VT-100 interface, where

you can view this data. The statistics monitored include: Command Count,

Command Alignment, Command Size, Readahead Statistics, Write Clustering

Statistics, and RAID 5/50 Write Statistics.

The controller maintains individual access statistics for each LUN and controller

port. These can be useful to help balance the load from the host. Identical

statistics are maintained for both reads and writes.

View All Statistics

1 From the Main menu, select the Statistics Menu and press <Enter>.

Main Menu Screen - Statistics Selected

121

Page 132: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

122

imageRAID-MUI.book Page 122 Tuesday, September 23, 2003 5:31 PM

2 Use the Up and Down Arrow keys to select the controller that you wish to

view the statistics on and press <Enter>.

Select Controller Screen

3 Use the Up and Down Arrow keys to select View All Statistics and press

<Enter>.

Statistics Type Menu Screen

The following screen displaying all statistics will appear.

View All Statistics

Page 133: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 123 Tuesday, September 23, 2003 5:31 PM

All Statistics Screen

Refer to the following sections of this chapter which covers each Statistic group

selected and a explanation of each item. Use <U> key to page up, the <D> key to

page down, and the <P> key to dump the information to a file.

Dump

The dump function enables you to write the data to a text file.

1 Click the Transfer pull-down menu and select Capture Text.

2 A Capture Text dialog window will prompt you to name the file. Enter a file

name and destination or choose the default name, and click Start.

3 Press the <P> key to dump the data.

You will notice the cursor jumps to the lower right corner of the screen and

once complete with return to the upper left of the screen.

4 Click the Transfer pull-down menu and select Capture Text > Stop.

5 Access the text file using a text editor.

Dump 123

Page 134: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

124

imageRAID-MUI.book Page 124 Tuesday, September 23, 2003 5:31 PM

Access Statistics

Access Statistics Screen

The Statistics groups can be viewed all together or individually, as well as on a

LUN or Port basis.

Each time statistics are viewed, the controller first outputs the current time and

the time since it was last reset. The statistics can be reset at any time. This is

useful in determining the access pattern for a particular test or period of time.

Statistic Description

Total Read Commands This is a count of the total number of read accesses (for all ports and LUNs) that have occurred since the controller was first powered on. This value is never reset, and indicates the number of commands that were sent to the controller from the time it was manufactured

Total Read Transfer This is a count of the total number of 512 byte blocks (for all ports and LUNs) that have been read since the controller was first powered on. This value is never reset, and indicates the amount of data transferred by the controller from the time it was manufactured.

Access Statistics

Page 135: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 125 Tuesday, September 23, 2003 5:31 PM

Total Read Commands Since Reset

This is a count of the total number of read accesses that have occurred since the statistics were reset, or the controller was last powered on.

Total Read Transfer Since Reset This is a count of the total number of 512 byte blocks that have been read since the statistics were reset, or the controller was last powered on.

Alignment This is the percentage of commands whose address is aligned on the specified address boundary. The alignment of a command from a host system is determined by the command’s address. In an optimal system, a write of one chunk of data would reside exactly within a chunk on one disk. However, if this is not the case, this write will be split up into two separate writes to two different data drives. This of course will have a negative effect on performance. To overcome these problems, the user can, with more sophisticated operating systems, set the access size and alignment to an optimal value. These statistics can help the user to tune the operating system.

Access Size This is the percentage of commands whose size is as specified. On occasions, an application may specify a particular access size, but the operating system may reduce this. This can lead to performance problems. For example, on Windows NT/2000 the maximum command size that the operating system will allow is 1MB. Additionally, some HBAs further reduce this value by default. However, some benchmark programs allow a larger access size to be specified, resulting in misleading results. By viewing the statistics on the controller, it is possible to determine the exact size of commands sent by the host, and so determine whether the results are appropriate.

The access size, in conjunction with the alignment, gives an indication of how many drives are involved in an access. For example, consider a RAID 5/50 array with a chunk size of 64K. In this case, a 64K access with an alignment of 8K will actually involve 2 data drives, since it needs to access some data in the first drive, and the remaining data in the next drive. This is clearly inefficient, and could be improved by setting the alignment to 64K on the operating system. If that is not possible, using a larger chunk size can help, as this reduces the number of accesses that span chunks. Aligning an access on the same value as the access size will improve performance, as it will ensure that there are not multi-chunk accesses for commands that are smaller than a chunk size.

Statistic Description

Access Statistics 125

Page 136: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

126

imageRAID-MUI.book Page 126 Tuesday, September 23, 2003 5:31 PM

Readahead Statistics

If sequential read commands are sent to the controller, it assumes that the

commands that follow may also be sequential. It can then go and perform a read

of the data before the host requests it. This improves performance, particularly

for smaller reads. The size of the readahead is calculated based on the original

command size, so the controller does not read too much data. The controller

maintains statistics for all readahead commands performed.

Readahead Statistics Screen

Statistic Description

Readahead Command Hit Rate This is the percentage of read command hits versus the total number of read commands that have been issued. This gives an indication of the sequential nature of the data access pattern from the host.

Readahead Command Efficiency

This is the percentage of the number of read command hits versus the projected number of readahead command hits. This is a measure of the efficiency of the readahead algorithm. A low value means that much of the data that the controller reads in the readahead command is not actually requested by the host.

Readahead Statistics

Page 137: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 127 Tuesday, September 23, 2003 5:31 PM

Sequential Command Interval In determining whether to perform a readahead or not, the controller will search back in the command queue whenever it receives a new read command that is not satisfied by an existing readahead cache buffer. In a multi threaded operating system, commands from one thread may be interspersed with commands from another thread. This requires that the controller not just check the immediately previous command. The controller will search back for a number of commands, to see if the new command is exactly sequential to any one of these previous commands. If it is, then the controller determines that the data access pattern is sequential, and so performs a readahead. These statistics record the average number of commands the controller must search back for when it finds a sequential command match, the maximum number, and also the percentage for each one of these values. These give an indication of the multi threaded nature of the host.

Statistic Description

Readahead Statistics 127

Page 138: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

128

imageRAID-MUI.book Page 128 Tuesday, September 23, 2003 5:31 PM

Command Cluster Statistics

To increase performance, the controller can cluster sequential write commands

together to create a larger write command. This results in less commands being

sent to the disk drives. Additionally, if sufficient data is clustered by the controller,

then it can perform a a full stripe write for RAID5/50 arrays. This significantly

improves performance. In cases where the host does not send a sufficient number

of outstanding writes, writeback cache can be used to delay the write to disk,

increasing the likelihood of clustering more data.

Command Cluster Statistics Screen

Statistic Description

Write Cluster Rate This is the percentage of the number of write commands that are part of a cluster versus the total number of write commands that have been issued. This gives an indication of the sequential nature of the data access pattern from the host, and of the performance of the writeback cache.

RAID 5/50 Partial Command Cluster Rate

This is the percentage of the number of clustered commands that wrap around the end of a stripe versus the total number of clustered commands. This gives an indication of the alignment of the operating system.

Command Cluster Statistics

Page 139: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 129 Tuesday, September 23, 2003 5:31 PM

Miscellaneous Statistics

To aid in tuning performance, some additional statistics for development use

have been included under the View Miscellaneous Statistics selection.

Miscellaneous Statistics Screen

RAID 5/50 Full Stripe Write Rate This is the percentage of the amount of data that is written as a full stripe write versus the total amount of data written. This gives an indication of the sequential nature of the data access pattern from the host, and of the performance of the writeback cache, for RAID 5/50 drive ranks.

Command Cluster Interval In determining whether to cluster write commands or not, the controller will search back in the command queue whenever it receives a new write command. In a multi threaded operating system, commands from each thread may be interspersed with commands from another thread. This requires that the controller not just check the immediately previous command. The controller will search back for a number of commands, to try to determine if the new command is exactly sequential to any one of these previous commands. If it is, then the controller determines that it can cluster these commands.

These statistics record the average and maximum number of commands the controller must search back for when it finds a sequential command match, and also the percentage for each one of these values.

Command Cluster Count When the controller clusters a write command, it may cluster a large number of them together. These statistics record the average and maximum number of commands the controller clusters, and also the percentage for each one of these values.

Statistic Description

Miscellaneous Statistics 129

Page 140: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

130

imageRAID-MUI.book Page 130 Tuesday, September 23, 2003 5:31 PM

View Access Statistics on Each LUN

This option allows you to view statistics for each LUN.

1 Use the Up and Down Arrow keys to select View Access Statistics on Each

LUN and press <Enter>.

Select LUN Screen

2 Select a LUN to view statistics on and press <Enter>.

3 Select a Controller Port to view Statistics on and press <Enter>.

You may select from Port 1, Port 2 or Both Ports.

Select Access Port to the Host LUN Screen

View Access Statistics on Each LUN

Page 141: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 131 Tuesday, September 23, 2003 5:31 PM

LUN Statistics Screen

Clear Access Statistics on Each LUN

This option allows you to clear the statistics for each LUN.

1 Use the Up and Down Arrow keys to select View Access Statistics on Each

LUN and press <Enter>.

2 Select a LUN to clear statistics on and press <Enter>.

3 Select a Controller Port to clear Statistics on and press <Enter>.

You may select from Port 1, Port 2 or Both Ports.

4 Select Yes to clear the statistics or No to cancel.

Clear Access Statistics on Each LUN 131

Page 142: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

132

imageRAID-MUI.book Page 132 Tuesday, September 23, 2003 5:31 PM

Clear Statistics

1 From the Main menu, select the Statistics Menu and press <Enter>.

Main Menu Screen - Statistics Selected

2 Use the Up and Down Arrow keys to select the controller that you wish to

clear the statistics on and press <Enter>.

Select Controller Screen

Clear Statistics

Page 143: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

imageRAID-MUI.book Page 133 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select Clear Statistics and press

<Enter>.

Statistics Type Menu Screen

4 Select Yes to clear all statistics or No to cancel.

Clear Statistics Screen

Clear Statistics 133

Page 144: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 7 - Statistics

134

imageRAID-MUI.book Page 134 Tuesday, September 23, 2003 5:31 PM

Clear Statistics

Page 145: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8

imageRAID-MUI.book Page 135 Tuesday, September 23, 2003 5:31 PM

Event Logs

Accessing Event Logs

The imageRAID Controller has a comprehensive non-volatile event log that can be

used for monitoring controller events and error conditions. The following event

types are logged: Drive Failures and Errors, Controller Failures and Errors, SES,

Temperature and Voltage Errors, and Fibre Loop Events and Errors (Drive and Host)

The minimum event log size is 4096 entries, and older events are overwritten as

necessary. Some repetitive events such as LIPs are appended to previous events,

so entries are not used up unnecessarily. A time stamp accompanies each event,

so the user can easily determine when the event happened. The time stamp of

both controllers is synchronized to make the troubleshooting tasks easier.

1 From the Main menu, select the Event Logs Menu and press <Enter>.

Main Menu Screen - Event Logs Selected

135

Page 146: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

136

imageRAID-MUI.book Page 136 Tuesday, September 23, 2003 5:31 PM

2 Use the Up and Down Arrow keys to select the controller for which you wish

to view the events and press <Enter>.

Controller Select for Event Logs Menu Screen

3 Use the Up and Down Arrow keys to select a specific set of events you wish

to view and press <Enter>.

Event Log Types Menu Screen

Accessing Event Logs

Page 147: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 137 Tuesday, September 23, 2003 5:31 PM

If you select View All Events the following screen will appear.

All Events Screen

Refer to the following sections of this chapter which covers each Event Log group

chosen and a explanation of each item.

The Events can be viewed all together or for a specific time period or device.

First, the current time and controller number are displayed. Then the events are

listed. It is possible to view a certain type of events, all event, or all events in a

certain time frame. It is advisable to capture the output to a log file, since the

number of events may exceed the VT-100 buffer.

These options are as follows:

Event Log Description

View All Events This option lists all events. The number of events is indicated.

View New Events This lists all events that have occurred since the event log has last been viewed.

View Last 50 Events This option lists the last 50 events.

View Last Hour/24 Hour Events This lists the events that occurred in the specified time.

Accessing Event Logs 137

Page 148: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

138

imageRAID-MUI.book Page 138 Tuesday, September 23, 2003 5:31 PM

View Drive Loop Events This lists all the events that have occurred on the drive loops. These include LIPs, drive failures, etc.

View Controller Port Loop Events

This lists all the events that have occurred on the host side of the controller port loops. These include LIPs, hosts logging in, etc.

View Environmental Events This lists events such as temperature warnings, voltage level errors, battery errors, etc.

View Failed Drive List This is a list of drives that the controller has marked as having failed. These drives have either failed in operation, or been removed.

Event Log Description

Accessing Event Logs

Page 149: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 139 Tuesday, September 23, 2003 5:31 PM

Controller Events

Following is a brief description of events that relate to the controller and

configuration.

Controller Event Messages Description Cause Action

Array xx Cache Disabled [Reasons]

The controller has disabled the writeback cache for the indicated reasons, as follows:

In Preparation For Shutdown:The controller has received a command to disable the writeback cache in preparation for shutdown.

Partner: The controller has disabled the cache because the partner controller has failed.

Battery: The controller has disabled the cache because the battery is either not present or fully charged.

Critical: The controller has disabled the cache because the array has become critical.

UPS: The controller has disabled the cache because a configured UPS has indicated power has been removed or communications has been lost with the UPS.

Disabling of writeback cache for the indicated reasons:

• A “prepare for shutdown” command has been received by the controller.

• The partner controller has failed.

• The battery is not charged or present.

• The array has become critical.

• The UPS has failed.

• No action necessary.

• Replace the failed controller.

• Charge the backup battery or re-install the battery.

• Resolve the array issue and rebuild the array.

• Replace the failed UPS.

Array xx Cache Re-Enabled The controller has re-enabled the writeback cache.

Re-enabling of writeback cache.

No action necessary.

Battery Failure This indicates that the onboard cache backup battery (if present) has failed.

Battery failure. Replace battery in the controller.

Battery OK This indicates that the onboard cache backup battery (if present) is fully charged.

Battery charging complete.

No action necessary.

Battery Charging This indicates that the onboard cache backup battery is charging.

Battery charging started.

No action necessary.

Cached Data Lost xxx Entries, yyy MB

If the controller is powered off with writeback cache still present, it is necessary to flush this data when power is restored. If power is removed for an extended time, the onboard battery will deplete, and the cached data will be lost.

Failure of power for an extended time with writeback cache present.

Check the file system.

Controller Events 139

Page 150: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

140

imageRAID-MUI.book Page 140 Tuesday, September 23, 2003 5:31 PM

Cntrl x Temp Exceeded: yy The current internal controller temperature is indicated in degrees Celsius. The controller’s internal temperature has exceeded the allowable limit, and the controller will shut down to prevent damage to internal components.

Blocked fan.

Failing fan.

Elevated ambient temperature.

Check enclosure for sufficient air flow.

Check for a failed fan, if found replace cooling fan module.

Check the ambient temperature of the environment, decrease the local ambient temperature.

Cntrl x Temp Warning: yy Shutdown will occur at zzC

The current internal controller temperature is indicated in degrees Celsius. The controller’s internal temperature is approaching the maximum allowable limit.

Blocked fan.

Failing fan.

Elevated ambient temperature.

Check enclosure for sufficient air flow.

Check for a failed fan, if found replace cooling fan module.

Check the ambient temperature of the environment, decrease the local ambient temperature.

Controller x Failed/Removed The specified controller has been removed, or has failed. Message is generated by the partner controller.

Failure or removal of one controller (partner) in an Active-Active configuration.

Replace the controller.

Controller x Timeout The specified controller has not responded in the allotted time. Message is generated by the partner controller.

Failure or removal of one controller (partner) in an Active-Active configuration.

Replace the controller.

Controller x Present The specified controller has been inserted.

Partner controller has been inserted.

No action necessary.

Controller x Valid The specified controller has passed it’s selftest and is now ready (failback).

Partner controller is ready to fail back.

No action necessary.

Controller Failover Started The process of failing over to the remaining controller has started.

Failure or removal of the partner controller.

No action necessary.

Controller Failover Completed The process of failing over to the remaining controller has completed.

Completion of failover process.

No action necessary.

Controller Event Messages Description Cause Action

Controller Events

Page 151: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 141 Tuesday, September 23, 2003 5:31 PM

Controller Failback Started The process of failing back to a replacement controller has started.

Partner controller started failback.

No action necessary.

Controller Failback Completed The process of failing back to a replacement controller has completed.

Completion of failback process.

No action necessary.

Controller Powered On The controller has been powered on or reset.

The controller was powered on.

No action necessary.

Controller Powered Off The controller has been powered off or removed.

Removal of controller or power.

No action necessary.

Controller Reset The controller has been reset either locally or remotely.

User initiated a controller reset.

No action necessary.

Controller Shutdown The controller has been shutdown either locally or remotely.

User initiated a controller shutdown.

The controller temperature was exceeded and the controller shut itself down.

No action necessary.

Check for a failed fan, replace as needed. Check for blocked air flow, correct as needed. Check for high ambient temperature, reduce the environments ambient temperature.

Controller Selftest Passed The controller has completed it’s power on selftest.

Selftest completion on startup.

No action necessary.

Controller Selftest Failed The controller has failed it’s power on selftest.

Selftest failure on startup.

Replace the controller.

Controller Firmware Upgraded to version xxxx

The controller’s firmware has been upgraded to the indicated version.

User upgraded the controller firmware.

No action necessary.

Configuration Changed The configuration has been changed.

A change in the configuration has occurred.

If you are using the Save Configuration feature, re-save your configuration information - it no longer matches, otherwise no action is necessary.

DMA Error This indicates an internal error in the controller.

Internal hardware failure.

Replace the controller. Contact Technical Support.

Event Log Cleared The controller’s event log has been erased.

The user has cleared the event log.

No action necessary.

Controller Event Messages Description Cause Action

Controller Events 141

Page 152: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

142

imageRAID-MUI.book Page 142 Tuesday, September 23, 2003 5:31 PM

Fatal Watchdog Error The controller watchdog timer has detected a fatal hardware or firmware error.

Internal hardware or firmware failure.

Replace the controller. Contact Technical Support.

Fatal SDRAM ECC The controller has detected unrecoverable ECC errors on the SDRAM, either a multiple bit error or uncorrectable single bit error.

Fault SDRAM or damaged internal bus.

Replace the controller.

Fatal Coprocessor Error The coprocessor has failed. Internal hardware or firmware failure on the coprocessor.

Replace the controller. Contact Technical Support.

Fatal Host FC Channel x Error The controller has detected a fatal error on the indicated host channel.

Memory or bus error on the indicated channel.

Replace the controller.

Fatal Drive FC Channel x Error The controller has detected a fatal error on the indicated drive channel.

Memory or bus error on the indicated channel.

Replace the controller.

Flush Mirrored Cache Started, xxx Entries, yyy MB

After failover, mirrored writeback cache needs to be flushed to the drives. This indicates the start of that process.

Failure or removal of the partner controller.

No action necessary.

Flush Mirrored Cache Completed

The flushing of mirrored writeback cache after a controller failure has completed.

Completion of mirrored cache flushing.

No action necessary.

Flush Cache Started, xxx Entries, yyy MB

If the controller is powered off with writeback cache still present, it is necessary to flush this data when power is restored. This indicates the start of that process.

Failure of power with writeback cache present.

No action necessary.

Flush Cache Completed The flushing of writeback cache after a power failure has completed.

Completion of cache flushing.

No action necessary.

Recovered SDRAM ECC Error, Address: xxxxxxxx Bit: yy

The controller has detected and corrected a single bit ECC error in the SDRAM. The address and error bit are indicated.

SDRAM error. If it repeats, replace the controller.

Resync Started A stripe synchronization of a RAID 5/50 set has started. This will be done when a controller fails or when powered off during a write.

A controller fails or is powered off during a RAID 5/50 write operation.

No action necessary.

Controller Event Messages Description Cause Action

Controller Events

Page 153: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 143 Tuesday, September 23, 2003 5:31 PM

Resync Completed A stripe synchronization of a RAID 5/50 set has completed.

A controller fails or is powered off during a RAID 5/50 write operation.

No action necessary.

UPS Failure This indicates that an attached UPS (if configured) has failed.

UPS has been disconnected or communications with the UPS has failed.

Check the UPS monitoring connections. Check the UPS, if necessary replace it.

UPS OK This indicates that an attached UPS (if configured) is functioning correctly.

UPS is connected. No action necessary.

Voltage Error: Monitored Voltage: xx.yyV

This indicates that the specified voltage has exceeded limits. This is a serious error, and should be reported to technical support.

Voltage regulator hardware failure.

Enclosure 5V or 12V problem in the power supply.

Replace the controller.

Replace the defective power supply.

Controller Version Mismatch Indicates the version of the controllers is different.

The cause of this is both controllers have different drive (Disk I/O Card) or host loop (Host I/O Card) operation parameters. The controllers need to be individually checked by looking at the controller information on the respective controller. (i.e., to check Controller 0, look on the VT-100 connected to Controller 0). Only the enabled drive and host loops will have information.

The action to be taken depends on how this occurred.

Insert matching controllers.

Upgrade the host loop (Host I/O Card) to dual loop. This could occur if a customer bought a 4311F first, then another controller to make it a 4321F. They would need to update the host port (Host I/O Card) of the original controller using the key provided by technical support.

If the user plugs a single loop controller into a standard dual loop system, purchase a licence or key to upgrade both loops (Disk I/O Card and Host I/O Card).

Controller Event Messages Description Cause Action

Controller Events 143

Page 154: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

144

imageRAID-MUI.book Page 144 Tuesday, September 23, 2003 5:31 PM

Drive Events

These events are related to the drive loops and arrays.

Drive Event Messages Description Cause Action

Array xx Critical This indicates the specified array is critical.

Drive removal or failure.

Replace the disk drive and rebuild the array.

Array xx Expansion Started Expansion of the indicated array has started.

Expansion has started.

No action necessary.

Array xx Expansion Restarted Expansion of the indicated array has restarted, after a power cycle or failover/failback.

Expansion has restarted.

No action necessary.

Array xx Expansion Complete Expansion of the indicated array has completed.

Expansion has completed.

No action necessary.

Array xx Initialization Started Initialization of the indicated array has started.

Initialization has started.

No action necessary.

Array xx Initialization Complete Initialization of the indicated array has completed.

Initialization has completed.

No action necessary.

Array xx Parity Check/Rewrite/Check and Rewrite Started

These events indicate that a RAID 5/50 Parity Check, Rewrite or Check and Rewrite has started.

Parity check started. No action necessary.

Array xx Parity Check/Rewrite/Check and Rewrite Completed, yy Errors

These events indicate that a RAID 5/50 Parity Check, Rewrite, or Check and Rewrite has completed. Any errors are indicated.

Parity check completed.

No action necessary.

Array xx Parity Check/Rewrite/Check and Rewrite Aborted, yy Errors

These events indicate that a RAID 5/50 Parity Check, Rewrite, or Check and Rewrite has been stopped. Any errors up to this point are indicated.

Parity check canceled by the user.

No action necessary.

Controller LIP: Drive Loop x The controller has initiated a LIP on the specified loop. This typically occurs during failover/failback or if a loop indicates problems.

Controller initiated a LIP.

No action necessary.

Drive Events

Page 155: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 145 Tuesday, September 23, 2003 5:31 PM

Data Underrun WWN:xx xx xx xx xx xx Py OP:zz

The controller has detected a data underrun from the indicated drive. This is caused by the controller detecting a bad CRC in a frame, and usually indicates a link problem, either with cabling or an enclosure. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

Loop error. Check cabling, Disk I/O card, and ensure that the disk drive is properly seated.

Drive Busy WWN:xx xx xx xx xx xx Py OP:zz

The drive indicated has returned a Busy status to a command. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

Drive is busy and cannot accept any more commands.

No action necessary.

Drive CC WWN:xx xx xx xx xx xx Py OP:zz SN:aa EXT:bb QL:cc

The drive indicated has returned a Check Condition status to a command. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

SN: SCSI sense key

EXT: SCSI extended sense key

QL: SCSI extended sense key qualifier

Typically due to a non-recoverable media error, hardware error, or loop error.

No action necessary.

Drive CC Failure WWN:xx xx xx xx xx xx A:yy D:zz

The drive listed has failed due to an unrecoverable error. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

Typically due to a non-recoverable media error or hardware error.

Replace the disk drive.

Drive Inserted WWN:xx xx xx xx xx xx xx ID;yyy

The drive indicated has been inserted. The meaning of each field is as follows:

WWN: Drive World Wide Name

ID: Drive hard ID

Drive was inserted. No action necessary.

Drive Event Messages Description Cause Action

Drive Events 145

Page 156: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

146

imageRAID-MUI.book Page 146 Tuesday, September 23, 2003 5:31 PM

Drive Invalid Block Size (Size) WWN:xx xx xx xx xx xx Py

This indicates that the specified drive has an invalid block size, and so cannot be used. A low level format is required. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

Size: Current block size (in hexadecimal). The controller requires 512 Bytes.

The drive has an invalid block size.

Replace the disk drive.

Drive Missing WWN:xx xx xx xx xx xx A:yy D:z

The drive listed has been marked as failed due to being removed from the disk drive enclosure. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

Drive has been removed or bypassed by the user, or has a serious hardware error.

Removal of cables connecting the enclosures.

Removal of power to daisy-chained enclosure(s).

Replace the disk drive.

Replace the cables.

Restore power to the daisy-chained enclosure(s).

Drive Rebuild Failure WWN:xx xx xx xx xx xx A:yy D:zz

Rebuild has failed due to an unrecoverable error on another drive in the array. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

Typically due to a non-recoverable media error or hardware error.

Backup all data and restore to a new array.

Drive Status aa WWN:xx xx xx xx xx xx Py OP:zz

The drive indicated has returned an unknown status to a command. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

Unknown status returned by the disk drive.

Contact Technical Support and provide them with a copy of the event log.

Drive Task Full WWN:xx xx xx xx xx xx Py OP:zz

The drive indicated has returned a Task Full to a command. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

Drive is busy and cannot accept any more commands.

No action necessary.

Drive Event Messages Description Cause Action

Drive Events

Page 157: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 147 Tuesday, September 23, 2003 5:31 PM

Drive Timeout WWN:xx xx xx xx xx xx Py OP:zz

The drive indicated has timed out for the specified command. The meaning of each field is as follows:

WWN: Drive World Wide Name

P: Drive port number

OP: SCSI command code

Drive hardware error or loop error.

Check cabling, Disk I/O cards, and ensure the disk drives are properly seated.

Drive Timeout Failure WWN:xx xx xx xx xx xx A:yy D:zz

The drive listed has failed because of a timeout. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

Drive error. Replace the disk drive.

Excessive Errors on Drive Loop x, Loop Disabled

The indicated loop has exceeded the allowable error count. The controller will not use this loop for data transfers. After two hours have elapsed, the loop will be re-enabled.

Damaged cable.

Faulty Disk I/O card (LRC failure).

Check/replace cable.

Check/replace Disk I/O card.

LIP: Drive Loop x (Repeated y times)

A LIP has occurred on the indicated drive loop.

Loop disruption or drive insertion.

No action necessary.

Loop Up: Drive Loop x The indicated drive loop is now up.

Loop becoming ready.

No action necessary.

Loop Down: Drive Loop x The indicated drive loop is now down.

Loop has gone down.

Check/replace cable.

Check/Replace Disk I/O card.

Loop Error On Drive Loop x The loop indicated is down. This means that the loop is no longer functional and no commands are being passed on this loop until a “Loop Up” is reported in the log again. This can indicate a problem with the loop, such as an LRC card or cable.

Loop is going down. Check/replace cable.

Check/Replace Disk I/O card.

Drive Event Messages Description Cause Action

Drive Events 147

Page 158: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

148

imageRAID-MUI.book Page 148 Tuesday, September 23, 2003 5:31 PM

New Drive Rebuild Failure WWN:xx xx xx xx xx xx A:yy D:zz

Rebuild has failed due to an unrecoverable error on the new drive. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

Typically due to a non-recoverable media error, or hardware error.

Replace new drive and initiate a rebuild.

Rebuild AbortedA:xx D:yy

A rebuild has been stopped by the user on the indicated drive. The meaning of each field is as follows:

A: Array number

D: Drive number in array

A rebuild was canceled by the user.

No action necessary.

Rebuild Started WWN:xx xx xx xx xx xx A:yy D:zz

A rebuild has started on the indicated drive. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

A rebuild has started. No action necessary.

Rebuild Restarted WWN:xx xx xx xx xx xx A:yy D:zz

A rebuild has restarted on the indicated drive. The meaning of each field is as follows:

WWN: Drive World Wide Name

A: Array number

D: Drive number in array

A rebuild has started. No action necessary.

Rebuild Complete A:xx D:yy A rebuild has completed on the indicated drive. The meaning of each field is as follows:

A: Array number

D: Drive number in array

A rebuild has completed.

No action necessary.

SES Initialized: SES LEVEL 1. Verify the Configuration

This event indicates that there is a problem with the SES processor, no drives are in the specified SES slots, or there is an address conflict with the enclosures.

No drives installed in slots 1 or 7.

Enclosure ID conflict.

Insert a disk drive in either or both drive slots 1 and 7.

Check the enclosure ID on all enclosure(s).

SES Initialized: SES LEVEL 3, Access: Critical

This event indicates that only one SES drive has been found in one or more of the attached enclosures.

No drives installed in slots 1 or 7.

Insert a disk drive in either or both drive slots 1 and 7.

Drive Event Messages Description Cause Action

Drive Events

Page 159: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 149 Tuesday, September 23, 2003 5:31 PM

SES Initialized: SES LEVEL 3, Access: Fault Tolerant

This event indicates that both SES drives have been found in one or more of the attached enclosures.

Drives are installed in slots 1 or 7.

No action necessary.

Some Or All Drives Not Available On Loop x

There is a problem with some drives on the indicated loop, but the loop is still up and functional.

Disk I/O card removal or failure.

Cable disconnected or failed.

Check/replace Disk I/O card.

Check/replace data cable.

WWN:xx xx xx xx xx xx ID:aaa FW Download Start Rev:yyyy

The drive listed has started a firmware upgrade to the indicated revision. The meaning of each field is as follows:

WWN: Drive World Wide Name

ID: Drive Target ID

Rev: New firmware version

A firmware upgrade has started.

No action necessary.

WWN:xx xx xx xx xx xx ID:aaa FW Download Complete

The drive listed has completed a firmware upgrade. The meaning of each field is as follows:

WWN: Drive World Wide Name

ID: Drive Target ID

The firmware upgrade is complete.

No action necessary.

WWN:xx xx xx xx xx xx ID:aaa Reallocate LBA yyyyyyyy

The controller has reallocated blocks at the indicated LBA in the drive. This is due to a verify failure. The meaning of each field is as follows:

WWN: Drive World Wide Name

ID: Drive Target ID

LBA: Address of reallocated blocks (hexadecimal)

Disk scrubbing detected an error.

No action necessary.

Drive Event Messages Description Cause Action

Drive Events 149

Page 160: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

150

imageRAID-MUI.book Page 150 Tuesday, September 23, 2003 5:31 PM

Controller Port Loop (Host) Events

These events are related to the host side Controller Port loops.

Controller Port Loop Event Messages Description Cause Action

Controller LIP: Host Loop x The controller has initiated a LIP on the specified loop. This typically occurs during failover/failback.

Controller initiated a LIP.

No action necessary.

CxPx Detected Power-on/Reset at ID:yyy LUN:zzz

The specified host has accessed a LUN for the first time, or for the first time following a reset. The meaning of each field is as follows:

CxPx: Controller and host port number

ID: Loop ID of the host

LUN: LUN number accessed

First access by a particular host after a LIP or reset.

No action necessary.

Host Port x Incorrect Address, Should Be:yyy Is:zzz

The host port indicated has not taken the Loop ID specified in the Hard Address setting. It is important to power cycle the controllers after changing this setting in the configuration.

Address conflict with either host adapter or other device on the same loop.

Resolve address conflict.

Host Px WWN: yy yy yy yy yy yy Logged in at ID:zzz

The indicated host system has logged into the controller. These events will only be listed for hosts that have SAN mappings created.

P: Host port number

WWN: Host World Wide Name

ID: ID of Host on the loop

Host systems logs into the controller.

No action necessary.

LIP: Host Loop x (Repeated y times)

A LIP has occurred on the indicated host loop.

Loop disruption or host booting.

No action necessary.

Loop Down: Host Loop x The indicated host loop is now down.

Loop is down. Check/replace cable.

Check/Replace Host I/O card.

Loop Up: Host Loop x The indicated host loop is now up.

Loop is ready. No action necessary.

Controller Port Loop (Host) Events

Page 161: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 151 Tuesday, September 23, 2003 5:31 PM

CC to Host ID:xxx LUN:yyy Pz OP:aa SN:bb EXT:cc QL:dd

This indicates that an unrecoverable drive error has occurred for a particular command. This may be due to a drive error in a non fault tolerant mode, such as RAID 0, or when the array is already in a degraded mode. The controller will pass the status from the drive back to the host system, to allow the host recovery mechanisms to be used. The meaning of each field is as follows:

ID: Host ID

LUN: LUN requested

P: Host port number

OP: SCSI command code

SN: SCSI sense key

EXT: SCSI extended sense key

QL: SCSI extended sense key qualifier

Data is not recoverable.

Backup all data, and restore to a new array.

Controller Port Loop Event Messages Description Cause Action

Controller Port Loop (Host) Events 151

Page 162: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

152

imageRAID-MUI.book Page 152 Tuesday, September 23, 2003 5:31 PM

SES Events

These events are related to the SES monitored enclosure components.

SES Event Messages Description Cause Action

Encl.yy Power supply zz OK WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated power supply is functioning correctly.

Normal condition reported.

No action necessary.

Encl.yy Power supply zz Critical WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated power supply is not functioning.

The specific power supply has failed.

The specific power supply is powered off.

Replace the power supply.

Ensure that the specific power supply On/Off button is in the On position ( l ).

Encl.yy Power supply zz Not Present WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated power supply is not present.

The power supply was removed.

Re-insert the power supply, connect the AC power cord and power on the power supply.

Encl.yy Fan zz OK WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated fan is functioning correctly.

Normal condition reported.

No action necessary.

Encl.yy Fan zz Critical WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated fan is not functioning.

A specific fan failure.

Total fan failure.

Cooling fan module was removed.

Replace the cooling fan module.

Replace the cooling fan module.

Re-inset the cooling fan module.

Encl.yy Temp. zz <aa>C OK WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated temperature sensor is within limits.

Temperature sensors are reporting normal temperatures in the enclosure.

No action required.

Encl.yy Temp. zz <aa>C Warning WWN: xx xx xx xx xx xx xx xx

(continued next page)

The controller has detected that the indicated temperature sensor has reached a warning limit.

Temperature sensors are reporting enclosure temperatures have reached the threshold of 70°C.

Automatic system shutdown will begin. In Active-Active controller configurations, one controller will shutdown its partner and shutdown the drives, then itself.

SES Events

Page 163: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 153 Tuesday, September 23, 2003 5:31 PM

Encl.yy Temp. zz <aa>C Warning WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated temperature sensor has reached a warning limit.

Temperature sensors are reporting enclosure temperatures have reached the threshold of 70°C.

Ensure that both cooling fans are operating normally. (Replace if needed.)

If the fans are set to automatic speed control, place the jumper on the Cooling fan module circuit board to force the fans to high speed.

If the environment ambient temperature is high, reduce the ambient temperature.

Ensure that the airflow is not blocked or restricted on the enclosure.

Encl.yy Temp. zz <aa>C Critical WWN: xx xx xx xx xx xx xx xx

The controller has detected that the indicated temperature sensor has reached a critical limit.

Temperature sensors are reporting enclosure temperatures have reached the threshold of 50°C.

If the fans are set to automatic speed control, place the jumper on the Cooling fan module circuit board to force the fans to high speed.

If the environment ambient temperature is high, reduce the ambient temperature.

Ensure that the airflow is not blocked or restricted on the enclosure.

Encl.xx Alarm zz is OFF WWN: yy yy yy yy yy yy

All conditions are normal or the alarm is off.

No condition being reported.

Alarm silenced.

No action necessary.

User pressed the Alarm Silence button on the front panel.

Encl.xx Alarm zz is ON WWN: yy yy yy yy yy yy

Alarm is on. A condition caused the alarm to sound.

Press the Alarm Silence button on the front panel and isolate the cause of the alarm.

SES Event Messages Description Cause Action

SES Events 153

Page 164: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

154

imageRAID-MUI.book Page 154 Tuesday, September 23, 2003 5:31 PM

Failed Drives

The controller maintains a list of failed drives. Drives are listed in the following

format:

Failed Drive:xx WWN: yy yy yy yy yy yy

Reason Code

The reason code may be one of the following:

Reason Codes Reason Action

Drive Timeout The drive has either timed out or been removed.

Re-insert the disk drive.

Replace the disk drive.

Command: xx Sense Key: yy Ext Sense: zz

The drive has failed for the specified command, with the indicated SCSI sense key and extended sense key.

Replace the disk drive.

Failed Drives

Page 165: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

imageRAID-MUI.book Page 155 Tuesday, September 23, 2003 5:31 PM

Clear Event Logs

1 From the Main menu, select the Event Logs Menu and press <Enter>.

Main Menu Screen - Statistics Selected

2 Use the Up and Down Arrow keys to select the controller that you wish to

clear the event logs on and press <Enter>.

Select Controller Screen

Clear Event Logs 155

Page 166: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 8 - Event Logs

156

imageRAID-MUI.book Page 156 Tuesday, September 23, 2003 5:31 PM

3 Use the Up and Down Arrow keys to select Clear Event Log and press

<Enter>.

Event Logs Type Menu - Clear Event Log Selected Screen

4 Select Yes to clear all events on this controller or No to cancel.

Clear Event Logs Screen

Clear Event Logs

Page 167: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9

imageRAID-MUI.book Page 157 Tuesday, September 23, 2003 5:31 PM

Diagnostics

The imageRAID controller has a comprehensive VT-100 Diagnostics menu. The

following operations may be performed from the diagnostics menu: Drive Loop

Integrity Test, Download and Program Operational Firmware, Download and

Program Drive Firmware, RAID 5/50 Parity Check, Command Tracing, Shutting

down the controllers, and capturing the diagnostics data.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

Main Menu Screen - Diagnostics Selected

2 Use the Up and Down Arrow keys to select the type of diagnostics or

controller operation you wish to access and press <Enter>.

157

Page 168: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

158

imageRAID-MUI.book Page 158 Tuesday, September 23, 2003 5:31 PM

From this menu you can enter the offline or online diagnostics, or reset or

shutdown the controller(s).

Offline diagnostics can only be performed when there is no activity and requires

that the enclosure be disconnected from the host system(s). Refer to “Offline

Diagnostics” on page 159.

Online diagnostics may be performed while there is no activity in progress with

the enclosure still connected to the host with no effect on the controller’s

operating status. Refer to “Online Diagnostics” on page 165.

Page 169: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 159 Tuesday, September 23, 2003 5:31 PM

Offline Diagnostics

Before performing this diagnostic, you must disconnect the host system(s) from

the enclosure.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

Main Menu Screen - Diagnostics Selected

2 Use the Up and Down Arrow keys to select Offline Diagnostics and press

<Enter>.

Offline Diagnostic Menu

Offline Diagnostics 159

Page 170: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

160

imageRAID-MUI.book Page 160 Tuesday, September 23, 2003 5:31 PM

Drive Loop Integrity Test

This test is used to test the drive loops in a configured system. The test is non-

destructive. It can give an indication of whether there are any signal integrity

issues, or whether there are marginal components such as drives, cables or

enclosures components.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Using the Up and Down Arrow keys, select Online Diagnostics and press

<Enter>.

3 Using the Up and Down Arrow keys, select Drive Loop Integrity Test and

press <Enter>.

Drive Loop Integrity Test Screen

4 Choose the appropriate test pattern and press <Enter>.

Alternating Data Pattern Screen

Drive Loop Integrity Test

Page 171: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 161 Tuesday, September 23, 2003 5:31 PM

There are two possible choices. The data pattern can be modified, but for

normal operations the default, alternating pattern is sufficient.

Random Data Pattern Screen

Alternating data pattern provides a mix of different patterns including

random and zero patterns.

Random data provides a complete random pattern.

5 Choose the Loop Under Test, use the Up and Down Arrow keys to select the

appropriate choice and press <Enter>.

Loop Under Test Screen

Drive Loop Integrity Test 161

Page 172: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

162

imageRAID-MUI.book Page 162 Tuesday, September 23, 2003 5:31 PM

It is possible to set up the test for one or both loops. Typically, both drive

loops would be tested simultaneously, unless a specific problem on one loop

is being isolated.

6 Use the Up and Down Arrow keys to select the test type and press <Enter>.

Test Type Screen

The mixed test, “Read/Write” is recommended.

7 Enter the test duration in minutes. Type in the value and press the <Enter>

key.

Test Duration Screen

Drive Loop Integrity Test

Page 173: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 163 Tuesday, September 23, 2003 5:31 PM

If possible, it is advisable to run this test for an extended period of time, such

as overnight. After selecting the test duration, the test starts. First, a map of

the connected drives is displayed along with the drive IDs. This is helpful to

assist with isolating an error to a specific area.

Test Display Screen

The display indicates the data patterns used to test the loops. These data

patterns are selected to show up typical loop integrity issues. The test can be

cancelled at any time by pressing the <Esc> key. After the test completes, it

returns to the Test Duration screen. To return to the previous menu(s) press

<Esc>.

If errors occur during the test, they are displayed. If there are errors greater

than 250, the test automatically aborts.

The following is a brief summary of the errors.

Error Description

Drive Loop x LIP Occurred A LIP has occurred on the specified drive loop. This can indicate a drive has been inserted or re initialized. It also can indicate a problem with the loop.

Drive Loop Integrity Test 163

Page 174: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

164

imageRAID-MUI.book Page 164 Tuesday, September 23, 2003 5:31 PM

For a properly configured system, errors should not occur. If any errors occur

during testing, the defective component should be identified and replaced. This

utility can be used after first installing a system, to ensure all cables and drives are

correctly installed, or whenever a system is moved or changed.

Drive Loop x Parity Error The drive has detected a CRC error while writing to it. This is typically due to a loop integrity issue before the drive in question.

Drive Loop x Timeout Error The specified drive has timed out. This error does not indicate a location for the error, since it may be before or after the drive.

Drive Loop x Underrun Error The controller has detected a CRC error while reading from a drive. This is typically due to a loop integrity issue after the drive in question.

Drive Loop x Reset Error The indicated drive has detected a reset on the loop. This error does not indicate a location for the error, since it may be before or after the drive.

Drive Loop x Internal Error An internal error has occurred while transferring data. This is not related to the loop, but indicates a problem with the controller.

Drive Loop x Loop (yyyy) Error An error has occurred indicated by the number yyyy. This type of error should be reported for further analysis.

Error Description

Drive Loop Integrity Test

Page 175: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 165 Tuesday, September 23, 2003 5:31 PM

Online Diagnostics

While the controller is connected to the host, it is possible to perform these

diagnostics: Controller Maintenance, Drive Maintenance, RAID 5/50 Parity Check,

Shutdown the controllers, and perform a diagnostics dump to the terminal window.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

Main Menu Screen - Diagnostics Selected

2 Use the Up and Down Arrow keys to select Online Diagnostics and press

<Enter>.

Online Diagnostic Menu

Online Diagnostics 165

Page 176: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

166

imageRAID-MUI.book Page 166 Tuesday, September 23, 2003 5:31 PM

Controller Maintenance

There may be an occasion which you are required to download new or updated

controller firmware, or simply reload the current firmware. To obtain the firmware,

you may need to download it from the support web site, on a CD-ROM or floppy

disk.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Online Diagnostics and press

<Enter>.

3 Use the Up and Down Arrow keys to select Controller Maintenance and

press <Enter>.

Online Diagnostics - Controller Maintenance Screen

4 Press <Enter> to begin the firmware download and re-program procedure.

Download Firmware Screen

Controller Maintenance

Page 177: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 167 Tuesday, September 23, 2003 5:31 PM

At the bottom of the screen a series of “C” characters will be displayed.

5 When the “C’s” appear, click the Transfer pull-down menu selection and

choose Send File. Then select the “1K Xmodem” protocol.

6 Click the browse button and locate the new Firmware file and click “Send.”

The firmware file will be named similar to “W_2_10.bin.”

NOTE: Ensure that the protocol “1K Xmodem” is selected. The “1K

Xmodem” protocol is preferred due to its superior error detection

(CRC vs. checksum).

From the “Send” screen you can monitor the progress. You can safely stop the

transfer without affecting your existing firmware any time during the transfer

until it has been completed. The upload does not overwrite the firmware

during the upload process, it writes the new code into RAM until completed,

then copies the new firmware code to the EEPROM after verification.

If you elect to stop a download in progress, ensure that the stop (abort)

command was completed by clicking the Cancel button.

Xmodem Send File Screen

7 After the transfer screen disappears, press the <Enter> key.

8 Restart the controller(s).

a From the Main menu use the Up and Down Arrow keys to select the

Diagnostics menu and press <Enter>.

Controller Maintenance 167

Page 178: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

168

imageRAID-MUI.book Page 168 Tuesday, September 23, 2003 5:31 PM

b Use the Up and Down Arrow keys to select Reset Controller and press

<Enter>.

Diagnostics - Reset Controller Screen

c Use the Up and Down Arrow keys to select a controller on which the

firmware was changed to reset it and press <Enter>.

Reset Controller Screen

d Select Yes to reset the controller and press <Enter>. Wait while the

controller reset takes place.

The RAID Controller(s) will restart with the new firmware.

NOTE: In duplex mode (dual controllers), the second controller’s firmware

is automatically updated during the restart procedure.

Controller Maintenance

Page 179: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 169 Tuesday, September 23, 2003 5:31 PM

Drive Maintenance

CAUTION: It is recommended that you backup data from any drives before

attempting a download. During the download process, it is essential

that no drives be inserted or removed, and that power is not

switched off. If a drive firmware download is interrupted, it is

possible that the drive will become unusable. For this reason, the

controller will not download drive firmware in parallel to all drives,

but one drive at a time. In this way, even if a power failure occurs,

the worst case scenario is one drive will be damaged.

The controller has the ability to download firmware to the attached disk drives.

Due to the large number of disk drives on the market, it is essential to use only

approved drive firmware file. Different drive manufacturers have different methods

for downloading drive firmware, sometimes requiring vendor unique utilities to

perform the download. Drive firmware is rigorously tested and a file is made

available to download. This eliminates the problems associated with host based

utilities, and also the possibility of permanently damaging a disk drive by

downloading incorrect firmware.

Download the Firmware from the Host

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Using the Up and Down Arrow keys, select Online Diagnostics and press

<Enter>.

3 Using the Up and Down Arrow keys, select Drive Maintenance and press

<Enter>.

Online Diagnostics - Drive Maintenance Screen

Drive Maintenance 169

Page 180: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

170

imageRAID-MUI.book Page 170 Tuesday, September 23, 2003 5:31 PM

4 Use the Up and Down Arrow keys to select the Download Drive Firmware to

Buffer transfer method and press <Enter>.

Download Firmware Screen

At the bottom of the screen a series of “C” characters will be displayed.

5 When the “C’s” appear, click the Transfer pull-down menu selection and

choose Send File. Then select the “1K Xmodem” protocol.

6 Click the browse button and locate the new Firmware file and click “Send.”

The firmware file will be named something similar to “hitachi_ggn3.bin.”

Xmodem Send File Screen

Here, the drive vendor and supported models are listed. This prevents the

incorrect firmware from being downloaded to a drive. The firmware version is

also displayed. It is also possible to read the firmware from a drive, if it has

previously been saved there. The controller reserves a buffer at the end of the

drives to store a copy of the drive’s firmware. This allows a new drive to be

updated in the field without requiring the firmware to be downloaded again.

Download the Firmware from the Host

Page 181: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 171 Tuesday, September 23, 2003 5:31 PM

Read Firmware from a Drive to the Buffer

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Online Diagnostics and press

<Enter>.

3 Use the Up and Down Arrow keys to select Drive Maintenance and press

<Enter>.

Online Diagnostics - Drive Maintenance Screen

4 Use the Up and Down Arrow keys to select the Read Firmware From Drive to

Buffer transfer method and press <Enter>.

Download Firmware Screen

5 Choose Read Firmware From Drive to Buffer and press <Enter>.

6 Select the appropriate firmware that is displayed and press <Enter>.

You will be returned to the Drive Firmware menu.

Read Firmware from a Drive to the Buffer 171

Page 182: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

172

imageRAID-MUI.book Page 172 Tuesday, September 23, 2003 5:31 PM

7 Choose one of the available options and press <Enter>.

Here, it is possible to download to all supported drives, all supported unused

or hot spare drives, or all supported drives that are not already at this

firmware level.

If any used drives are to be updated, the following warning will appear.

CAUTION: If a drive firmware download is interrupted, it is possible that the

drive will become unusable. For this reason, the controller will

not download drive firmware in parallel to all drives, but one

drive at a time.

When downloading drive firmware, the controller first checks the vendor and

product ID of each drive to determine whether the firmware should be

updated. Then, it updates the drive. The following is a typical sequence of

drive firmware download, with mixed drives:

8 Power cycle the enclosure after a drive firmware download. This will ensure

the drives use the correct firmware.

Read Firmware from a Drive to the Buffer

Page 183: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 173 Tuesday, September 23, 2003 5:31 PM

RAID 5/50 Parity Check

If an array is not initialized during creation (i.e., trusted) or if both controllers are

replaced after the array is powered off with write operations in progress, it may

be necessary to verify the parity data on the array. It is also be desirable to

perform this check periodically from time to time.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Online Diagnostics and press <Enter>.

3 Use the Up and Down Arrow keys to select RAID 5/50 Parity Check and press <Enter>.

Online Diagnostics - RAID 5/50 Parity Check Screen

4 Use the Up and Down Arrow keys to select either All RAID 5/50 Arrays or Specific RAID 5/50 Arrays and press <Enter>.

Parity Check Menu Screen

RAID 5/50 Parity Check 173

Page 184: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

174

imageRAID-MUI.book Page 174 Tuesday, September 23, 2003 5:31 PM

5 Use the Up and Down Arrow keys to select the parity check options you

wish to use and press <Enter>.

Parity Check Options Menu Screen

Parity check options are described below:

6 Use the Up and Down Arrow keys to select Yes to start the parity check or No

to cancel, then press <Enter>.

Option Description

Check Parity This option reads all the data and parity, calculates the XOR of the data, and compares it to the parity. If there is an error, it is displayed.

Rewrite Parity This option reads all the data, calculates the XOR of the data, and writes this out as the new parity. This is the fastest to complete, since it does not have the overhead of a comparison.

Check and Rewrite Parity This option reads all the data and parity, calculates the XOR of the data, and compares it to the parity. Then, if there is a discrepancy, it writes out the new parity. This is the slowest to complete, since it has the overhead of a comparison as well as a rewrite.

RAID 5/50 Parity Check

Page 185: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 175 Tuesday, September 23, 2003 5:31 PM

Apply Parity Check Screen

7 Select to apply and start the parity check and press <Enter>.

After starting a parity check, the RAID 5/50 Parity Check menu returns to the

Parity Check Menu screen.

Here, it is possible to cancel a parity check. If an error occurs during the

check or rewrite, it is displayed on the terminal. Additionally, an event is

entered in the event log upon start and completion.

Command Tracing

It is possible to monitor the commands that a host is sending to the controller,

and this has a variety of uses.

It can be used to verify that a host is communicating with the controller, or as a

method of debugging a system. All commands that are sent to the controller are

displayed on the terminal screen.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Use the Up and Down Arrow keys to select Online Diagnostics and press

<Enter>.

3 Use the Up and Down Arrow keys to select Target Command Trace Settings

and press <Enter>.

Command Tracing 175

Page 186: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

176

imageRAID-MUI.book Page 176 Tuesday, September 23, 2003 5:31 PM

Online Diagnostics - Target Command Trace Settings Screen

4 Press the <Enter> key to toggle the command trace to be Enabled or

Disabled.

Command Trace “Enable/Disable” Screen

5 Press the <Esc> key to return to the previous menu.

All incoming commands will be displayed on the terminal until the trace

mode is disabled.

Here, the important information presented is that the command is on port 1

(T1) from the host with ID 124 (ID:7c) for LUN 0. The command is a SCSI

inquiry command (CDB: 12).

Command Tracing

Page 187: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

imageRAID-MUI.book Page 177 Tuesday, September 23, 2003 5:31 PM

Shutdown Controller

This option provides the user with the ability to gracefully shutdown the controllers.

When this method is used, all cache is written before the controller is shutdown.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Using the Up and Down Arrow keys, select Shutdown Controller and press

<Enter>.

Diagnostic Menu - Shutdown Selected

3 Use the Up and Down Arrow keys to select a controller you wish to

shutdown and press <Enter>.

Select Controller Screen

4 Use the Up and Down Arrow keys to select “Yes” to shutdown the controller

or “No” to cancel and return to the Main menu. The Controller will shutdown.

Shutdown Controller 177

Page 188: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Chapter 9 - Diagnostics

178

imageRAID-MUI.book Page 178 Tuesday, September 23, 2003 5:31 PM

Shutdown Controller Screen

5 To restart the controller, you can remove and re-insert the RAID Controller in

its slot, or power cycle the enclosure.

Diagnostics Dump

During the process of troubleshooting a problem, it may be helpful to capture the

diagnostics data. The information capture to the VT-100 screen can then be saved

to an external file for later analysis.

1 From the Main menu, select the Diagnostics Menu and press <Enter>.

2 Using the Up and Down Arrow keys, select Diagnostics Dump and press

<Enter>.

Diagnostic Menu - Diagnostics Dump Selected

The diagnostic data is immediately sent to another VT-100 window. From

there you may view or export the data to another file for later use.

Diagnostics Dump

Page 189: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A

imageRAID-MUI.book Page 179 Tuesday, September 23, 2003 5:31 PM

Optimizing RAID 5 Write Performance

Introduction

With a typical RAID 5 implementation, there are a number of steps necessary to

write the data to the media. Every write from the host system will typically

generate two XOR operations and their associated data transfers, to two drives. If

the accesses are sequential, the parity information will be updated a number of

times in succession. However, if the host writes sufficient data to cover a

complete stripe, the parity data does not need to be updated for each write, but it

can be recalculated instead. This operation takes only one XOR operation per

host write, compared to two for a standard RAID 5 write. The number of data

transfers necessary are also reduced, increasing the available bandwidth. This

type of write access is termed a “Full Stripe Write.”

Distribution of Data and Parity in a RAID 5 with Five Drives

P (20-23) C20 C21 C22 C23 Stripe 5

P (16-19)C17 C18 C19 Stripe 4

P (12-15)C13 C14 C15 Stripe 3

P (8-11)C9 C10 C11 Stripe 2

P (4-7)

C16

C12

C8

C4 C5 C6 C7 Stripe 1

P (0-3) C0 C1 C2 C3 Stripe 0

179

Page 190: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A - Optimizing RAID 5 Write Performance

180

imageRAID-MUI.book Page 180 Tuesday, September 23, 2003 5:31 PM

The illustration on the previous page displays the distribution of data chunks

(denoted by Cx) and their associated parity (denoted by P(y-z)) in a RAID 5 array

of five drives. An “array” is defined as a set of drives, on which data is

distributed. An array will have one RAID level. A “chunk” is the amount of

contiguous data stored on one drive before the controller switches over to the

next drive. This parameter is adjustable from 64K to 256K, and should be

carefully chosen to match the access sizes of the operating system. A Stripe is a

set of disk chunks in an array with the same address. In the above example,

Stripe 0 consists of C0, C1, C2, and C3 and their associated parity.

Maximum performance will be achieved when all drives are performing multiple

commands in parallel. To take advantage of a Full Stripe Write, the host has to

send enough data to the controller. This can be accomplished in two ways.

Firstly, if the host sends one command with sufficient data to fill a stripe, then the

controller can perform a Full Stripe Write. Alternatively, if the host sends

multiple sequential commands, smaller than a stripe size (typically matching the

chunk size), the controller can internally combine these commands to get the

same effect. In the above example, if a 256K chunk size is used, then the stripe

size is 1MB (4 chunks * 256K). So, for maximum performance, the host could

either send 5 * 1 MB write commands, or 20 * 256K write commands.

The effectiveness of the controller’s ability to perform a Full Stripe Write depends

on a number of parameters:

Sequential Access

If the commands sent from the host are not sequential, the controller will not be

able to cluster them together. So, unless each individual access is sufficient to fill

a stripe, a Full Stripe Write will not occur.

Number of Outstanding Commands

For the controller to successfully cluster commands, there has to be a number of

write commands sent simultaneously. Setting the host to send up to 64

commands should prove adequate. Alternatively, enabling writeback cache will

have a similar effect, as the controller can then cluster sequential commands even

if the host only sends a small number of commands at a time.

Sequential Access

Page 191: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A - Optimizing RAID 5 Write Performance

imageRAID-MUI.book Page 181 Tuesday, September 23, 2003 5:31 PM

Access Size

With very small accesses, it is necessary to have a large number of commands to

cluster together to fill up a full stripe. So, the larger the access size the better. It

is best to use an access size that will fill a chunk. Of course, even if a stripe is

not filled up, small sequential writes will still benefit from command clustering.

Access Alignment

The alignment of a command from a host system is determined by the

command’s address. In an optimal system, a write of one chunk of data would

reside exactly within a chunk on one disk. However, if this is not the case, this

write will be split up into two separate writes to two different data drives. This

will have a negative effect on performance. To overcome these problems, the

user can, with more sophisticated operating systems, set the access size and

alignment to an optimal value.

As can be seen from the figure below, to get the highest performance from this

system, it is necessary to have a number of stripes being written in parallel. As

array expand, with more and more drives, the number of commands (and

amount of sequential data) necessary to do this increases.

Distribution of Data and Parity in a RAID 5 with Eight Drives

P (56-62) C56 C57 C58 C59 C60 C61 C62 Stripe 8

C53 C54 C55 Stripe 7

C46 C47 C48 Stripe 6

C39 C61 C62 Stripe 5

C32 C33 C34 Stripe 4

C24 C25 C26 C27 Stripe 3

P (49-55)C50 C51 C52

P (42-48)C43 C44 C45

P (20-23)C36 C37 C38

P (28-34)C29 C30 C31

P (21-27)C22 C23

C17 C18 C19 C20 Stripe 2P (14-20)C15 C16

C10 C11 C12 C13 Stripe 1

C3 C4 C5 C6 Stripe 0

P (7-13)

C49

C42

C35

C28

C21

C14

C7 C8 C9

P (0-6) C0 C1 C2

Access Size 181

Page 192: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A - Optimizing RAID 5 Write Performance

182

imageRAID-MUI.book Page 182 Tuesday, September 23, 2003 5:31 PM

In the figure on the previous page, we can see that seven chunks of sequential

data are necessary to fill a stripe. To have multiple commands active for all disk

drives, this requires more data than for the case with five drives. As can be seen,

this number will increase as the number of drives increases. If a large number of

drives are used, it may get difficult to achieve maximum performance, as it

becomes more difficult to cluster a large number of commands to achieve a Full

Stripe Write.

RAID 5 Sub-Array

This difficulty in realizing the maximum performance possible introduces the

concept of a Sub-Array. Suppose an array consisted of two RAID 5 sets, as

described in the figure on page 179. If these are then striped, the resulting array

would appear as shown in the figure below. In this case, in order for a Full

Stripe Write to be performed, it is still only necessary to cluster four write

commands together, as opposed to the seven necessary in the figure below. The

array of drives appears as two separate sub-arrays, each with it’s own rotating

parity.

Distribution of Data and Parity in a RAID 5 with Ten Drives and Two Sub-Arrays

It can be seen that the more sub-arrays used, the more likely it is for a Full Stripe

Write to occur, and hence the higher the performance. It is recommended to use

either four or five drives in a sub-array, for best performance. It can be seen on

the following page the figure shows that even with 15 drives, it is still possible to

perform Full Stripe Writes, by clustering together 4 chunks of data.

P (40-43) P (44-47)C40 C41 C42 C43 C44 C45 Stripe 5

C36 C37 Stripe 4

C27 C28 C30

C38

Stripe 3

C19 C21 P (20-23) Stripe 2

C12 P (12-15) C13 Stripe 1

C3 P (4-7) C4 C5 Stripe 0

P (32-35)C33 C34 C35

C29C25 C26 P (24-27)

C20C17 P (16-19) C18

C11P (8-11) C9 C10

C2C0 C1

C46

P (28-31)

C22

C14

C6

C39

C47

C31

C23

C15

C7

P (36-39)C32

C24

C16

C8

P (0-3)

RAID 5 Sub-Array

Page 193: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A - Optimizing RAID 5 Write Performance

imageRAID-MUI.book Page 183 Tuesday, September 23, 2003 5:31 PM

Distribution of Data and Parity in a RAID 5 with Fifteen Drives and Three Sub-Arrays

As well as the performance advantage gained from using multiple sub-arrays,

there are a number of other advantages:

Multiple Drive Failures

In a configuration with multiple sub-arrays, it is possible for the array to sustain

multiple drive failures, provided that there is only one failure in each sub-array.

Faster Rebuild

A rebuild operation must read data and calculate parity from all the remaining

drives in the array. If multiple sub-arrays are used, this means that it is only

necessary to read the data from the remaining drives in the sub-array, not all of

the drives in the array. This increases both the rebuild speed and the speed of

access to missing data, which also has to be recreated from the remaining drives.

Summary

In summary, for maximum performance using RAID 5, it is recommended to use

four or five drives in a sub-array. If there are more than five drives in a sub-array,

it is better to use a smaller chunk size, say 64K or 128K, as this will lead to more

Full Stripe Writes.

P PC60 C61 C62 C63 C64 C65

C52 C53

C39 C40 C42

C54

C27 C29 P

C16 P C17

C3 P C4 C5

PC49 C50 C51

C41C37 C38 P

C28C25 P C26

C15P C13 C14

C2C0 C1

C66

P

C30

C18

C6

C55

C67

C43

C31

C19

C7

P

P C68

C56

C45

C57

C32 C33

C20 P

P C8

C44

C69

C46

P

C21

C9

C58

C70

P

C34

C22

C10

C59

Stripe 5

Stripe 4

Stripe 3

Stripe 2

Stripe 1

Stripe 0

C71

C47

C35

C23

C11

PC48

C36

C24

C12

P

Multiple Drive Failures 183

Page 194: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Appendix A - Optimizing RAID 5 Write Performance

184

imageRAID-MUI.book Page 184 Tuesday, September 23, 2003 5:31 PM

Summary

Page 195: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

Index

imageRAID-MUI.book Page 185 Tuesday, September 23, 2003 5:31 PM

AAccess Alignment 181

Access Size 125, 181

Access Statistics 124

AccessingConfiguration Utility 1

Accessing Event Logs 135

Adding Hot Spare Drives 89

Additional Configuration 109

Advanced Configuration 83

Alignment 125

Array Name 18

Assigning Hot Spare 33

Auto Hot Spare 85

Auto Rebuild 83

BBackground Verification 116

BBU Battery Hold-Up Times 29

CCapturing Screen

Dump 123

Check and Rewrite Parity 174

Check Parity 174

Chunk Size 20

Clear Access Statistics on Each LUN 131

Clear Event Logs 155

Clear Statistics 132

Clearing Configuration 106

Cluster Statistics 128

Command Cluster Count 129

Command Cluster Interval 129

Command Cluster Statistics 128

Command Tracing 175

Communications Parameters 2

Config Name 10

Configuration UtilityAccessing 1

Configuration WWN 9

Configuring Array Writeback Cache 26

ControllerShutdown 177

Controller EventBattery Charging 139Battery Failure 139Battery OK 139Cache Disabled 139Cache Re-Enabled 139Cached Data Lost 139Cntrl Temp Exceeded 140Cntrl Temp Warning 140Configuration Changed 141Controller Failback Completed 141Controller Failback Started 141Controller Failed 140Controller Failover Completed 140Controller Failover Started 140Controller Firmware Upgraded 141Controller Powered Off 141Controller Powered On 141Controller Present 140Controller Removed 140Controller Reset 141Controller Selftest Failed 141Controller Selftest Passed 141Controller Shutdown 141Controller Timeout 140Controller Valid 140DMA Error 141Encl Temp Critical 153Encl Temp OK 152

185

Page 196: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

186

imageRAID-MUI.book Page 186 Tuesday, September 23, 2003 5:31 PM

Encl Temp Warning 152, 153Event Log Cleared 141Fan Critical 152Fan OK 152Fatal Coprocessor Error 142Fatal Drive FC Channel Error 142Fatal Host FC Channel Error 142Fatal SDRAM ECC 142Fatal Watchdog Error 142Flush Cache Completed 142Flush Cache Started 142Flush Mirrored Cache 142Flush Mirrored Cache Started 142Power Supply Critical 152Power Supply Not Present 152Power Supply OK 152Recovered SDRAM ECC Error 142Resync Completed 143Resync Started 142UPS Failure 143UPS OK 143Voltage Error 143

Controller Events 139

Controller Information 8, 104

Controller Information Display 9

Controller LUN 91

Controller Maintenance 166

Controller Port Connection 97

Controller Port Data Rate 99

Controller Port Different Node Name 95

Controller Port Loop Events 150

Controller Port Loop x Status 10

Controller SES 118

Controller Voltage 10

Controller WWN 9

Creating a Disk LUN 51

Creating Arrays 14

Current Controller Time 10

Current Power on Time 10

DDelete a LUN 58

Delete Array 35

Diagnostics 157

Diagnostics Dump 178

Different Node Name 95

Disk LUNs 47

Download the Firmware from the Host 169

Drive Capacity Reserve 23

Drive EventArray Critical 144Array Expansion Complete 144Array Expansion Restarted 144Array Expansion Started 144Array Initialization Complete 144Array Initialization Started 144Array Parity Check Canceled 144Array Parity Check Completed 144Array Parity Check Started 144Controller LIP 144Data Underrun 145Drive Busy 145Drive CC 145Drive CC Failure 145Drive Inserted 145Drive Invalid Block Size 146Drive Missing 146Drive Rebuild Failure 146Drive Status 146Drive Task Full 146Drive Timeout 147Drive Timeout Failure 147Excessive Errors on Drive Loop 147FW Download Complete 149FW Download Start 149LIP-Drive Loop 147Loop Down 147Loop Error 147Loop Up 147New Drive Rebuild Failure 148Reallocate LBA 149Rebuild Aborted 148Rebuild Complete 148Rebuild Restarted 148Rebuild Started 148SES Initialized Level 1 148, 149SES Initialized Level 3 148

Drive Events 144Not Available On Loop 149

Drive Loop Integrity 160

Drive Loop Integrity Test 160

Drive Loop x Status 10

Drive Maintenance 169

DumpCapturing Text 123

Index

Page 197: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 187 Tuesday, September 23, 2003 5:31 PM

EEvent log size 135

Event Logs 135

Exclusive Access 63

Expand a LUN 54

FFailed Drives 154

Faster Rebuild 183

Firmware Date 10

Firmware Revision 10

Firmware Time 10

HHardware Configuration Settings 91

Host EventCC to Host ID 151Controller LIP 150Detected Power-on/Reset 150Host Port Incorrect Address 150Logged in at ID 150Loop Down 150Loop Up 150

Host Events 150

Hot Spare Configuration 87

Hot Spare DrivesViewing 87

LLast Configuration Time 10

Loop Information 8

LUN Assignment 47

LUN Availability 48

LUN Segmentation 47

MMapped LUN Number 48, 63

Mapping Availability 63

Mapping Name 63

Maximum No. of Drives 11

Menu System 5

Minimum No. of Drives 11

Miscellaneous Statistics 129

Modify Configuration Name 109

Modify Configuration WWN 111

Modify Mapped LUN 60

NNavigating 4

Node Name 63

Numbering Convention vi

OOffline Diagnostics 159

Onboard Temperature 10

Online Diagnostics 165

Optimization for RAID 5 Arrays 13

PPool spare 34

Port Connection Options 97

Port Data Rate 99

Port ID Settings 93

Port Name 63

RRAID 5 Sub-Array 182

RAID 5 Write Performance 179

RAID 5/50 Full Stripe Write Rate 129

RAID 5/50 Parity Check 173

RAID 5/50 Partial Command Cluster Rate 128

RAID Level 19

RAID Levels 11

Read Firmware from Drive 171

Read Only Access 63

Read/Write Access 63

Read-Ahead Cache 26

Readahead Command Efficiency 126

Readahead Command Hit Rate 126

Readahead Statistics 126

Rebuild Parameters 83

Removing Hot Spare Drives 89

Rewrite Parity 174

RS-232 PortSettings 2

RS-232 Settings 102

Run-time Information 8

SSAN LUN Mapping 63

SAN LUN MappingsCreating 66

Index 187

Page 198: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

188

imageRAID-MUI.book Page 188 Tuesday, September 23, 2003 5:31 PM

Deleting 74Modify 75Viewing 65

Select Drives 22

Sequential Access 180

Sequential Command Interval 127

SES EventAlarm is ON 153Encl Alarm is OFF 153

SES Events 118, 152

Set LUN Availability 56

Setting Single Controller Mode 115

Shutdown Controller 177

Single Controller Mode 115

Statistics 121

Sub-array Selection 23

Summary of the errorsOffline 163

TTemperature Information 8

TerminologyArrays 12LUNs 47SAN LUNs 63

Test DurationOffline Diagnostics 162

Total Power on Count 10

Total Power on Time 10

Total Read Commands 124

Total Read Commands Since Reset 125

Total Read Transfer 124

Total Read Transfer Since Reset 125

Trust Array 45

UUnassigned Free Space 48, 49

UPS Configuration 108

VVerification 116

View Access Statistics on Each LUN 130

View Configuration Field Explanation 16

View Unused Drives 17

Viewing Connected Hosts 80

Voltage Information 8

WWrite Cluster Rate 128

Writeback Cache 26

WWNController 8

Index

Page 199: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 189 Tuesday, September 23, 2003 5:31 PM

Page 200: imageRAID VT-100 Menu based Interface Software Guide · SOFTWARE GUIDE VT-100 imageRAID® Series Storage System (Menu-based User Interface) imageRAID-MUI.book Page 1 Tuesday, September

imageRAID-MUI.book Page 190 Tuesday, September 23, 2003 5:31 PM

www.fel.fujitsu.com 91-9-94626001 (A)August 2003

Fujitsu Europe LimitedHayes Park CentralHayes End RoadHayes, Middlesex, England UB4 8FE44.208.573.4444