Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
Danger of electrical shock, burns or death. Always remove all power sources before attempting any repair, service or diagnostic work. Power can be present from shore power, generator, inverter or battery. All power sources must
be disabled and secured before performing any service.
If you lack the skills, tools or equipment to perform diagnostic or repair work leave such work to an authorized
Winnebago Industries dealer or other qualified shop.
Copyright © 2014 Winnebago Industries, Inc.
3
VIEW AB
265
1.
1B1
ROUTE TANK SENSOR WIRES SO THEY DO NOT PASS OVER SENSORS.USE WIRE TIE MOUNT 155366-01-000 AND WIRE TIE 8343-01-000AS NEEDED. TANK SURFACE MUST BE CLEANED USING ISOPROPYLALCOHOL AND PRIMED WITH PRIMER 94.
WIRING INSTL-BODY,12V
2.
NOTES:
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
265
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
1 10
1.5
184893
1B1 CODES/STANDARDS USA
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
AB
A
RELEASE
14 P34B
VIEW AA184893
AA
2
C
CHKR
PART NO
DSNR
REV
3
P.E.
6
REVISION RECORD
57
D
ALL DIMENSIONS ARE IN MILLIMETERS
A
ANGLE
ORIG. DATE
FIRST USED
D
MATERIAL:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
B
4
ZONE
WHOLE DIM (X)
C
REV DWGNO
DATE
THIRD ANGLE
4
DFTR-ORIG
ONE-PLACE (X.X)
DO NOT SCALE DRAWING
26
TWO-PLACE (X.XX)
A
R
8
1
DFTR
5
PROJECTION
DATE
TITLE:
8 REF:
UNSPECIFIED TOLERANCES ARE:
3
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
M.E.
7
B
1
REV
OFSHEET
1
0.50
CODES/STANDARDS-CSA/CMVSS
DETAIL AD
WIN WINNEBAGO ONLY
ITA ITASCA ONLY
FEATUREDRAWING NO.
184893-01
184893-02 ITA
WIN
PLATE-WALL149557-03-CHTSCREWG39-08-08U (2)
PANEL-LIGHT132862-09-CHTSCREWG39-10-12U (4)
AD
3 WIRE PASSES THROUGH FLOOR IN THIS AREA.
SWITCH-PUMP108357-21-000ACTUATOR108356-03-CHT(8 PIN HOUSING WITHCIRCUITS XXZ,GGA,FFZ,YYF)
SWITCH-AUTO LEVEL108357-18-000ACTUATOR108356-03-CHT(8 PIN HOUSING WITHCIRCUITS SSD,SSE,SSC,SSE,SSF)
SWITCH-SERVICE LAMP108357-01-000ACTUATOR108356-01-CHT(8 PIN HOUSING WITHCIRCUITS WA,JF)
LO1-34
ROUTEWIRE ASM-COACHDOWN RIGHT SIDE
TO GROUND BAR
BRACKET185915-01-CHT (2)SCREWG39-10-12U (8)
MODULE-WATER PUMP176001-01-000SCREWG39-08-12U (2)DETAIL AD
WIRE ASM-TANK,WATER151317-01-000
3
WIRE ASM-COACH185307-01-000
DATA CABLESTO INVERTER
2-PIN HOUSINGTO WATER PUMP
WIRE ASM-TANK,AUX HOLDING151316-02-000
ROUTEWIRE ASM-COACHDOWN RIGHT SIDE
3
3
TO SLIDEOUT MODULE(SEE SHT 10)
TO SLIDEOUT ROOM
WIRE ASM-TANK MAIN151317-01-000
3
YYF
TO SLIDEOUT MODULE(SEE SHT 10)
GGAFFZ
XXZ
*1
84
89
3 *
PLUG-PLASTIC,2"61420-15-000
CABLE
INPUT CONNECTIONS
PORTABLESATELLITE
DISH
Battery GroundSwitch Load
16-Apr-2014
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET 184893
14 P34B
2
WIRING INSTL-BODY,12V
184893
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
265
1B1
1B1
265
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
TEMP SENSOR171186-02-CHTSCREWG67-06-10U (2)
2 PIN HOUSINGTO SIDEWALL
LED-2C5
DETECTOR-LP GAS150138-03-CHT
2 PIN HOUSINGTO TV LIFT
LED-2C2
WIRE ASM-OVHD186199-01-000
WIRE ASM-SLIDEOUT182421-01-000
TEMP SENSOR171186-02-CHTSCREWG67-06-10U (2)
PLATE-WALL149557-12-CHTCONNECTOR-F,90 RIGHT ANGLE176986-01-000
CONNECTIONCOACH TO SLIDEOUT
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
1.
9 PIN HOUSINGTO SIDEWALL
SWITCHDETAIL EB
SWITCHDETAIL EJ
SWITCHDETAIL EK
SWITCHDETAIL EN
SWITCHDETAIL EM
SWITCHDETAIL EM
WIRE ASM-OVHD186217-01-000
2 PIN HOUSINGTO SIDEWALL
WIRE ASM-OVHD186200-01-000
2 PIN HOUSINGTO SIDEWALL
*1
84
89
3 *
16-Apr-2014
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
WIRING INSTL-BODY,12V
14 P34B
3
184893
184893
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
SWITCHDETAIL EC
CABINET ASM-SPEAKER143006-01-XXXSCREWG67-10-10U (4)SPEAKER124884-02-000GRILL151844-01-CHTSCREW76790-06-000 (4) HB
SWITCHDETAIL EH
2 PIN HOUSINGTO WIRE ASM-SIDEWALL
WIRE ASM-OVHD186200-01-000
LCS-1
DD
TO WIRE ASM-ROOF
SWITCHDETAIL EESWITCH
DETAIL EG
RELAY-FURNACE63912-02-000 (2)SCREWG12-08-12U (2)
4 PIN HOUSINGTO SIDEWALL
COAX TOWIRE ASM-ROOFDETAIL CA
2 PIN HOUSINGTO WIRE ASM-SIDEWALL
12V BREAKERPANELDETAIL DA
4 PIN HOUSINGTO FURNACE
SWITCHDETAIL ED
TO AWNING
LED-2C2
SWITCHDETAIL EM
EXT ENT CTR180544-02-XXX
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
SWITCHDETAIL EM
WIRE PASSES THROUGH FLOOR IN THIS AREA.
NOTES:
2
1.
2 PIN HOUSINGTO SIDEWALL
LAMP-MAKEUP166329-01-CHT
2
SWITCHDETAIL EA
1DF
4 PIN HOUSINGTO WATER HEATER
1B1
CODES/STANDARDS USA
265
265
1DF
1B1
EXT TV ENTERTAINMENT CENTER
CODES/STANDARDS-CSA/CMVSS
TO SLIDEOUT MODULE(SEE SHEET 10)
LED-2C3
LAMP-WALL119258-73-CHT (2)BULB117805-02-000 (2)SCREWG67-10-24U (4)CONNECTOR58028-01-000 (4)
WIRE ASM-OVHD186218-01-000
SWITCHDETAIL EF
2 PIN HOUSINGTO SIDEWALL
12V-RECEPTACLE(SEE SHEET 4)
2MISC CONNECTIONSTO LOAD CENTERDETAILS HC
SWITCHDETAIL EN
*1
84
89
3 *
WIRE ASM-ROOF
COAX(RED)
COAX(RED)
DETAIL CA
COAX(GLD)
COAX(GLD)
ADAPTOR82134-01-000 (2)
WIRE ASM-COACH
16-Apr-2014
14 P34B
4
WIRING INSTL-BODY,12V
184893
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
BUSS BAR
PLATE
KNURLED NUT(SUPPLIED WITHCIRCUIT BREAKER)
184893
5.0
HEXNUT-PALNUT(SUPPLIED WITHCIRCUIT BREAKER)
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
DETAIL DC
1B1
DETAIL DB-DB
1B1
CODES/STANDARDS USA
WHT
265
NOTES:
RECEPTACLE-12V132958-01-000
YEL
CODES/STANDARDS-CSA/CMVSS265
LAMPS LAMPS LAMPS LAMPS
FRONTFURNACE/
LAMPS
HOUSE 12V CIRCUIT BREAKERS(PUSH TO RESET)
EXHFANS
MONITOR/TV
LPDETECTOR
REFRIG
12VRECPS
LAMPS LAMPS
LAMPS LAMPS REARFURNACE/
LAMPS
SOFALAMPS
LAMPS
WB HHA WC NM JG JF
ET JA JB JE JD JC
JJT EEC BBZ LLA KKY FFZ
15 15 15 15 15 6
15 15 15 15 15 10
15 15 15 15 15
J6 BLKFROM WIREASM-CHASSISSCREWG39-08-06U
K6 BLKFROM WIREASM-CHASSISSCREWG39-08-06U
Z6 BLKFROM WIREASM-CHASSISSCREWG39-08-06U
BUSS BAR141744-05-000 (3)SCREWG39-08-06U (3)
DETAIL DA(BACK VIEW)
DETAIL DA(FRONT VIEW)
CIRCUIT BREAKER93654-02-000 (15)(15 AMP)SCREWG52-06-04U (15)
CIRCUIT BREAKER93654-01-000(6 AMP)SCREWG52-06-04UWASHEROME02B-04-071
CIRCUIT BREAKER182283-01-000(20 AMP)SCREWG52-06-04UWASHEROME02B-04-071
PLATE139067-06-CHTLABEL92547-14-000SCREWG11-10-12U (4)
DB
DB
SWITCH-COACHBATT DISC174757-07-CHT(CIRCUITS KF,LG,LJ,LH,KF,WC)WIRE ASM-THERM186796-01-000
SWITCH-PATIO AWNING174757-03-CHT(CIRCUITS FFN,FFP,FFR,MC,ML)
SWITCH-STEP COVER174757-08-CHT(CIRCUITS GX,HHC,KA,KA,HHD,GX,MC,ML)
DETAIL DD
CIRCUIT BREAKER93654-05-000(10 AMP)SCREWG52-06-04UWASHER0ME02B-04-071PLUG081211-06-000
79W
RESIDENTIAL REFRIGERATOR PKG15L
SWITCH-PORCH LIGHTS174757-22-CHT(CIRCUITS JF,PJ,MC,PJ,ML)
SWITCH-DOOR AWNING174757-09-CHT(CIRCUITS FFS,FFF,FFE,FFE,FFG,FFT,MC,ML)
SWITCH-ENTRY DOOR LOCK174757-02-CHT(CIRCUITS PY,MK,PX,MC,ML)
SWITCH-AWNING POWER174757-19-CHT(CIRCUITS FFD,FFT,MC,FFT,ML)
SWITCH-COACH LIGHTS174757-17-CHT(CIRCUITS FFW,PL,FFX,MC,ML)
RECEPTACLE-12V132958-01-000DETAIL DC
SWITCH-BLANK145754-01-CHT
PANEL-SWITCH,3-WAY174834-02-CHT (4)
SWITCH-ENTRY STEP174757-27-CHT(CIRCUITS ES,ER,MC,ML)
SWITCH-AWNINGWIND SENSOR174757-18-CHT(CIRCUITS UUK,UUL,UUM,MC,ML)
PLATE-SWITCH176859-07-CHTSCREWG67-10-12U (6)
SWITCH-COMPT LIGHTS174757-21-CHT(CIRCUITS WC,NW,MC,NW,ML)
PLATE-SWITCH176859-10-CHTSCREWG67-10-12U (4)
RELAY-LIGHTING/AWNING063912-02-000 (2)
SWITCH-CHASSBATT DISC174757-06-CHT(CIRCUITS UUC,TTY,UUB,TTZ,UUC,MK)WIRE ASM-THERM186796-01-000
15L
79W REFRIGERATOR-4 DOOR
*1
84
89
3 *
SWITCH-AWNING LIGHT174757-38-CHT(CIRCUITS ZZK,JF,MC,MC,WC)
1 SEE AWNING INSTL FOR ADDITIONAL INFORMATION.
AWNING CONTROL-BOX(REF)SCREWG39-08-12U (2)
1
KEYLESS ENTRY MODULE176367-04-000SCREWG11-08-08U (2)
PANEL-SWITCHMOUNTING,SINGLE174834-01-CHT (2)
16-Apr-2014
5
14 P34B
184893
WIRING INSTL-BODY,12V
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET 184893
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
265
CODES/STANDARDS-CSA/CMVSS
1B1
1B1
265
CODES/STANDARDS USA
DETAIL EG
MONITOR SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-30-CHTSCREWG11-08-08U (2)
DETAIL EH
LLAJJV
DETAIL EM(4 PLACES)
CEILING SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-07-CHTSCREWG11-08-08U (2)
PEJC
DETAIL EN(2 PLACES)
FAN ACCENTSWITCH-ROCKER135740-01-CHT135740-04-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-49-CHTSCREWG11-08-08U (4)WIRE ASM-RESISTOR140195-01-000
DETAIL EJ
JEYU
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL EF
YELBBL
SWITCH-ROCKER135740-02-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-13-CHTSCREWG11-08-08U (4)
DETAIL EA
DETAIL EK
DETAIL EC
DETAIL ED
SWITCH-PUMP108357-21-000ACTUATOR108356-23-CHTSCREWG11-06-10U (2)
SWITCH-TV LIFT108357-16-000ACTUATOR108356-26-CHTPLATE144363-02-CHTSCREWG11-06-10U (2)
HALL CEILINGAISLE SWITCH-ROCKER135740-01-CHT135740-02-CHT (2)SWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-25-CHTSCREWG11-08-08U (4)
DETAIL EL
YNJDYM
PCJDNY
JDNU
SWITCH-ROCKER135740-01-CHT135740-02-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-18-CHTSCREWG11-08-08U (4)
FFXJGA
FFWJC
FAN - CEILING,BEDROOM41Y
DETAIL EB
AISLE CEILING
YMPHNY
WXNU YN
LLAPG
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
GALLEY LOUNGE
FAN ACCENT SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-49-CHTSCREWG11-08-08U (4)
GSGR
NMYT
MAKEUPFAN
HHAKJ LLA
PD
SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-38-CHTSCREWG11-08-08U (4)
DETAIL EE
41Y
GGXJE
FFY
SWITCH108357-06-000ACTUATOR108356-24-CHT(CIRCUITSDR,DU,DT)
LABEL-WARNING116549-01-000
LABEL-SLIDEOUT,DRIVERS,FRT163992-01-CHT
LABEL-SLIDEOUT,PASS,REAR163992-03-CHT
SWITCH-KEYLOCK163097-01-000LABEL163988-02-CHTPANEL163987-01-CHTSCREW76790-05-000 (4)
SWITCH108357-06-000ACTUATOR108356-24-CHT(CIRCUITSHHF,HHE,DT)
SWITCH108357-06-000ACTUATOR108356-24-CHT(CIRCUITSBBM,BBN,DT)
LABEL-SLIDEOUT,PASS,FRONT163992-04-CHT
VALANCE ACCENT SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-36-CHTSCREWG11-08-08U (4)
DETAIL EP
LLARRC
LLARRB
*1
84
89
3 *
WATERPUMP
PASSENGER'SSIDE REAR
PASSENGER'SSIDE FRONT
This switch must be onand park brake appliedto operate any slide room.We recommend runnin theengine to insure adequatebattery power. ON
MASTER SLIDE ROOMCONTROL SWITCH
NOTICESlide room will not operateuntil slide room locks are retracted.
OFF
CRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury.
116549-01G
WARNING
DRIVER'SSIDE FRONT
16-Apr-2014
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
14 P34B
WIRING INSTL-BODY,12V
184893
6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
184893
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
265
LED-414
CODES/STANDARDS USA1B1
LF1N32
265
CODES/STANDARDS-CSA/CMVSS
LSH-3
1B1
LED-2
2
RED-FFYBLK-KKZ
WIRE ASM-ROOF
FAN139134-01-CHTSCREWG11-10-16U (3)CONNECTOR58028-01-000 (2)DETAIL FA
DETAIL FA
CONNECT MOTOR BLUTO SWITCH BLU ANDMOTOR BLK TO SWITCH BLK
1
CENTER FAN OVER 25MM HOLE IN ROOF.
NOTES:
SWITCH-FAN,REVERSING
APPLY LOCTITE P/N 62917-06-000 TOFAN BLADE MOUNTING NUT THREADS.
21 41Y
41Y FAN - CEILING,BEDROOM
*1
84
89
3 *
16-Apr-2014
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
14 P34B
WIRING INSTL-BODY,12V
184893
7 184893
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CONNECT 2-PIN HOUSINGFROM ROOF ASM TOSATELLITE DISH HEREAND ADD CONVOLUTED TUBING
HHB
GALLEY VENTDETAIL GD
VIEW GB-GB
THE SATELLITE DISH WIRE CONNECTIONSARE TO BE PLACED ON THE CENTERLINEOF THE MOTORHOME FACING FORWARD
RED
GBGB
DETAIL GD
WHT
ORG
DETAIL GA
CONNECT CABLE ASM COAX(ORG-2) FROM ROOF ASMTO SEC INPUT ON SATELLITE DISH
GR
193
BLK
BLK
HHB
1B1
KJ
DETAIL GC
WIREASM-ROOF
ANT-5
CONNECT CABLE ASM COAX (ORG)FROM ROOF ASM TO MAIN INPUTON SATELLITE DISH
265
HHC
2
GS
200
60
BATH VENTDETAIL GC
DI-348P
DETAIL GA
NOTES:
SEE MANUFACTURER'S INSTALLATION FOR ADDITIONAL INFORMATION.
REMOVE ALL SHIPPING RESTRAINTS BEFORE MOUNTING.2
1
CODES/STANDARDS USA
1
WIREASM-ROOF
CONNECTER58028-01-000 (2)
CONNECTER58028-01-000 (4)
GRN
TV ANTENNA-AMPLIFIED SYSTEM
48P
193
265
SAT TV SYSTEM IN-MOTION
CODES/STANDARDS-CSA/CMVSS
1B1
SATELLITE HD TV SYSTEM AUTOC783
DA-4783
DETAIL GE1
1
WHEN APPLYING ROOFSEALANT TO SATELLITEDISH, PLACE ROOF SEALANT HERE(APPROXIMATELY 75MM WIDE)AND PUSH THE CABLES INTOTHE SEALANT TO STABILIZE THEM.
THE SATELLITE DISHAND WIRE CONNECTIONSARE TO BE PLACED ONTHE CENTERLINE OF THEMOTORHOME FACING FORWARD.
CONNECT CABLE ASM-COAX FROMROOF ASM TO COAX CABLES ONSATELLITE DISH AND CONNECT10' CABLE-DATA FROM ROOF ASMTO DATA CABLE FROM SATELLITEDISH AND PLACE ALL CONNECTIONSBACK INTO ROOF ASM.
SEPARATE CABLES ANDINSTALL WIRE COVEROVER HOLE IN ROOFASM WITH CABLES EXITINGON PASSENGERS SIDE.
DETAIL GE
*1
84
89
3 *
GF
DETAIL GFSOL-1 282
163594
161
115
1355
SOLAR PANEL - 100 WATT282
16-Apr-2014
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET
1B1
8
14 P34B
CODES/STANDARDS-CSA/CMVSS
WIRING INSTL-BODY,12V
184893
265
NOTES:
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
184893
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
265
1B1
DETAIL HB
LED-2C2
SWITCHDETAIL EP
1 SET 'GEN TYPE' TO MATCH GENERATOR MODEL INSTALLED IN COACH.SET 'SAFE TYPE' TO 'IGNITION'.SEE OPERATORS MANUAL FOR SETUP PROCEDURE.
SET 'BAT TYPE' TO 'AGM2'SET 'LBCO' TO '11VDC'.SEE OPERATORS MANUAL FOR SETUP PROCEDURE.
4
SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
WIRE IS FROM WIRE ASM-IP,MAIN. SEE WIRINGINSTL-FRONT END FOR ADDITIONAL INFORMATION.
5
2
3
3
MAGNUM INVERTER
DATA CABLE(GREEN TAPE)
WIRE ASM-COACH
REMOTE
DATA CABLE(NO TAPE)
12-PINHOUSING
12VDC
DETAIL HD
5
PANEL-MONITOR,PCS 50 AMP174384-06-000SCREWG11-08-08U (4)
THERMOSTAT-A/C FURNACE171186-04-CHT
MODULE-AUTOGENERATOR START158425-01-000
2
SLIDEOUT SWITCHESDETAIL EL
MONITOR-PANEL175724-02-000SCREWG11-08-08U (4)
REMOTE PANEL-INVERTER175385-02-000SCREWG11-08-08U (2)
1
4
3
VIEW HC
ROUTE WIRE ASMOVER CABINET HERE
SSH
LAMP ASM-ROPE160259-02-132
LAMP ASM-ROPE160259-02-072
WIRE ASM-CHASSIS(REF)
3
SSG
CAT6 CABLES TOHDMI MATRIXFROM WIRE ASM-A/V
WIRE ASM A/V(REF)
WIRE ASM-COACHREMOVE KNOCKOUTDETAIL HD
LIGHT-READING174060-01-CHT (2)SCREWG11-08-16U (4)CONNECTOR58028-01-000 (2)
WIRE ASM-ROOF
CONNECTION FORROPE LAMP
RRC,LLBTO ROPE LAMPCONNECTOR58028-01-000 (4)
2-WAY RCA CABLETO HOME THEATER
110V LOAD CENTER(REF)
TRANSFORMER(REF)
*1
84
89
3 *
PASSENGER'SSIDE REAR
PumpHeaterL.P.
ONE PLACE
Levels
Tank
Water
BatteryHeater
Electric
PASSENGER'SSIDE FRONT
This switch must be onand park brake appliedto operate any slide room.We recommend runnin theengine to insure adequatebattery power. ON
MASTER SLIDE ROOMCONTROL SWITCH
NOTICESlide room will not operateuntil slide room locks are retracted.
OFF
CRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury.
116549-01G
WARNING
DRIVER'SSIDE FRONT
SETAUTOGEN ENTER
START/PREHEAT
STOP/PRIME
MONITOR
16-Apr-2014
14 P34B
WIRING INSTL-BODY,12V
184893
184893
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET 9
WIRE ASM-TRAY,FRONT LH182420-01-000
WIRE ASM-TRAY,FRONT RH182419-01-000
SPEAKER-5-1/4" 3-WAY W/GRILL180783-01-CHT (4)
SPEAKER-5-1/4" 3-WAY W/GRILL180783-01-CHT (3)
12-PIN HOUSING TOWIRE ASM-ROOF
9-PIN HOUSING TOWIRE ASM-ROOF
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
*1
84
89
3 *
LED-2C5
LED-2C4
265
1B1
1B1
CODES/STANDARDS-CSA/CMVSS
265
CODES/STANDARDS USA
16-Apr-2014
14 P34B
WIRING INSTL-BODY,12V
184893
184893
D
C
1
FIRST USED
8 3
B
28 1
DO NOT SCALE DRAWING
4
4DWGNO
3
TITLE:
C
6
B
7 5
PART NO
2
D
REV
5
AA
6
7
SHEET 10
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
WIRE ASM-SCHWINTEK178398-02-000 (15FT)(LEFT FRONTROOM-FRONT MOTOR)
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
WIRE ASM-SCHWINTEK178398-02-000 (15FT)(RIGHT REARROOM-REAR MOTOR)
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
WIRE ASM-SCHWINTEK178398-02-000 (15FT)(RIGHT REARROOM-FRONT MOTOR)
WIRE ASM-SCHWINTEK178398-02-000 (15FT)(RIGHT REARROOM-FRONT MOTOR)
CLAMP-CABLE10495-02-000 (26)
1
1900 DROP6-PIN HOUSING TOSCHWINTEK MOTOR
1
WIRE ASM-SCHWINTEK178398-04-000 (25FT)(LEFT FRONTROOM-REAR MOTOR)
WIRE ASM-SCHWINTEK178398-02-000 (15FT)(RIGHT REARROOM-REAR MOTOR)
DETAIL KC
1
CLAMP-CABLE10495-02-000 (11)
1
KB
NOTES:
KA
ROUTE WIRES ALONG FLOOR.
KC
CONTROL-SLIDEOUT,IN-WALL178451-01-000
1B1
1B1
265
265
CODES/STANDARDS-CSA/CMVSS
CODES/STANDARDS USA
HHE
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
DETAIL KA
CONTROL-SLIDEOUT,INWALL186340-01-000
6-PIN HOUSING FROMLEFT FRONT ROOMFRONT MOTOR(20FT CABLE)
LLL
DR
LLK
DU
6-PIN HOUSING FROMLEFT FRONT ROOMREAR MOTOR(25FT CABLE)
HHF
LLR
DETAIL KB
LLP
BBNBBM
CONTROL-SLIDEOUT,IN-WALL178451-01-000
6-PIN HOUSING FROMRIGHT REAR ROOMREAR MOTOR(15FT CABLE)
6-PIN HOUSING FROMRIGHT REAR ROOMFRONT MOTOR(15FT CABLE)
PPA
NNZ
6-PIN HOUSING FROMRIGHT FRONT ROOMFRONT MOTOR(15FT CABLE)
6-PIN HOUSING FROMRIGHT FRONT ROOMREAR MOTOR(15FT CABLE)
*1
84
89
3 *
RETEXTMOTOR 1 MOTOR 2
GND
PWR
RET
EXT
500:1 MO
TOR
S
MO
TOR
1
GND
MO
TOR
2
PWR
RET
EXTM
OTO
R 1
MO
TOR
2
GND
PWR
16-Apr-2014