STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th St, Shawnee, KS 66227 Test Model: LED7WMR16/NFL/8XXK-DIM-G6 Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution Test Engineer: Daniel Duan Report Number: RSZ150312502-10A1 Test Date: 2015-05-21 to 2015-05-25 Report Date: 2016-01-26 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

IES LM-79-08 TEST REPORT - eiko.com · PDF file0.0° 2351 2351 2351 2351 2351 2351 2351 2351 5.0° 1711 1694 1727 1796 1895 2013 2122 2202 10.0° 909 881 906 967

Embed Size (px)

Citation preview

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

For

EiKO Global, LLC23220 W 84th St, Shawnee, KS 66227

Test Model: LED7WMR16/NFL/8XXK-DIM-G6

Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution

Test Engineer: Daniel Duan

Report Number: RSZ150312502-10A1

Test Date: 2015-05-21 to 2015-05-25

Report Date: 2016-01-26

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

Two samples were received on 2015-03-12. One was tested in integrating sphere and the other was tested in goniophotometer.

Model Tested:

Manufacturer:

Product Designation:

Burning Time Before Test:

Rated Values:

Rated Voltage/Frequency:

Rated Power:

Nominal CCT:

LED7WMR16/NFL/8XXK-DIM-G6

EiKO Global, LLC

Directional LED Lamp 0hour(For New Products)

AC12V 60Hz

7 W

3000K

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration date

Calibration due date

Integrating Sphere SENSING N/A N/A 25 2015-03-05 2016-03-04

Power Meter SENSING UI2008 908735 10.0-600.0V 2015-03-05 2016-03-04

Spectral photometer SENSING SPR3000 s0902024 350nm 800nm 2015-03-05 2016-03-04

AC Power Supply EVERFINE APW-105N 970663 220V±10% 50HZ 2015-03-05 2016-03-04

Standard Light Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26

Thermal Meter SENSING N/A N/A 25 2015-03-05 2016-03-04

DC Power Supply ITECH IT6154 0061 0417 6471 0010

19 0~32V 2015-03-05 2016-03-04

AC Power Supply EVERFINE VPS1030

PWM 1012017 0-150V 0-300V 2015-03-05 2016-03-04

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-04

Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-04

Goniophotometer EVERFINE GO-R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-20 2016-03-19

Wireless Remote Sensor N/A 433MHz N/A 0 ~50 ;-20 ~60 2015-03-24 2016-03-23

Standard Light Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 3 of 12 The NVLAP Lab Code is 200707-0.

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.3% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1(K=2) , at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial uniformity. The product was operated in its intended orientation in application and was recorded in this report. The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Base up

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

12.0 60 0.625 6.6 0.885

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

487.704 1.369 73.895 3048 -0.00214

Chromaticity Coordinate

x y u v u' v'

0.4306 0.3966 0.2497 0.3450 0.2497 0.5174

Color Rendering Index

Ra 83.6

R1 R2 R3 R4 82 92 96 81

R5 R6 R7 R8 83 90 83 62

R9 R10 R11 R12 15 82 80 75

R13 R14 R15

85 98 76

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW nm mW nm mW nm mW nm mW

380 3.216E-04 465 1.487E-02 550 2.708E-02 635 3.440E-02 720 4.610E-03

385 2.151E-04 470 1.255E-02 555 2.878E-02 640 3.200E-02 725 4.053E-03

390 1.480E-04 475 1.071E-02 560 3.051E-02 645 2.945E-02 730 3.513E-03

395 1.220E-04 480 9.904E-03 565 3.234E-02 650 2.695E-02 735 3.058E-03

400 1.302E-04 485 1.032E-02 570 3.430E-02 655 2.455E-02 740 2.620E-03

405 2.271E-04 490 1.139E-02 575 3.611E-02 660 2.205E-02 745 2.371E-03

410 4.772E-04 495 1.290E-02 580 3.811E-02 665 1.981E-02 750 2.078E-03

415 1.016E-03 500 1.444E-02 585 3.994E-02 670 1.756E-02 755 1.812E-03

420 1.873E-03 505 1.600E-02 590 4.133E-02 675 1.559E-02 760 1.628E-03

425 3.204E-03 510 1.744E-02 595 4.239E-02 680 1.374E-02 765 1.437E-03

430 5.053E-03 515 1.865E-02 600 4.300E-02 685 1.210E-02 770 1.299E-03

435 7.743E-03 520 1.970E-02 605 4.316E-02 690 1.059E-02 775 1.183E-03

440 1.151E-02 525 2.069E-02 610 4.280E-02 695 9.284E-03 780 1.073E-03

445 1.665E-02 530 2.183E-02 615 4.187E-02 700 8.105E-03

450 2.150E-02 535 2.302E-02 620 4.037E-02 705 7.086E-03

455 2.227E-02 540 2.424E-02 625 3.868E-02 710 6.137E-03

460 1.854E-02 545 2.564E-02 630 3.666E-02 715 5.293E-03

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50 0.55

sample

7-STEP 2200K

7-STEP 2500K

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hours

Test orientation: Base up

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

12.02 60 0.636 6.561 0.8582

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

462.399 70.48 2393 0.39 0.35

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 19.4 19.1 19.3 19.6 19.4

Field Angle (10% Imax): 43.2 42.7 42.8 43.6 43.1

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data C 0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 2351 2351 2351 2351 2351 2351 2351 2351 5.0° 1711 1694 1727 1796 1895 2013 2122 2202

10.0° 909 881 906 967 1060 1186 1322 1427 15.0° 450 415 427 465 519 579 656 718 20.0° 231 215 214 223 247 287 330 361 25.0° 121 113 111 116 132 150 175 196 30.0° 63 58 58 63 68 80 92 108 35.0° 32 30 31 33 38 43 50 58 40.0° 19 18 19 20 22 24 27 31 45.0° 14 13 13 14 15 16 17 19 50.0° 11 11 11 12 12 12 13 14 55.0° 10 10 10 10 11 11 11 12 60.0° 8 8 8 9 9 9 9 10 65.0° 7 7 7 7 7 7 8 8 70.0° 6 5 6 6 6 6 7 7 75.0° 4 4 4 5 5 5 5 5 80.0° 3 2 3 3 3 3 4 4 85.0° 1 1 1 1 2 2 2 2 90.0° 0 0 0 0 0 0 0 1 95.0° 0 0 0 0 0 0 0 0 100.0° 0 0 0 0 0 0 0 0 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 0 0 0 0 0 0 0 0 155.0° 0 0 0 0 0 0 0 0 160.0° 0 0 0 0 0 0 0 0 165.0° 0 0 0 0 0 0 0 0 170.0° 0 0 0 0 0 0 0 0 175.0° 0 0 0 0 0 0 0 0 180.0° 0 0 0 0 0 0 0 0

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.) C 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 2351 2351 2351 2351 2351 2351 2351 2351 5.0° 2195 2190 2154 2079 1988 1884 1797 1724 10.0° 1409 1399 1359 1278 1188 1083 1000 909 15.0° 713 709 686 647 597 541 496 457 20.0° 359 360 358 334 310 286 267 245 25.0° 202 206 200 184 177 163 149 133 30.0° 113 114 108 104 95 87 81 68 35.0° 61 61 59 55 51 47 42 35 40.0° 33 32 31 30 27 26 23 20 45.0° 19 19 18 18 17 16 15 14 50.0° 13 14 13 13 13 13 12 12 55.0° 12 12 11 11 11 11 10 10 60.0° 10 10 9 9 8 9 8 8 65.0° 8 8 8 7 7 7 7 7 70.0° 6 7 7 6 6 6 5 5 75.0° 5 5 5 5 5 5 4 4 80.0° 4 4 3 3 3 3 3 2 85.0° 2 2 2 2 2 1 1 1 90.0° 1 0 0 0 0 0 0 0 95.0° 0 0 0 0 0 0 0 0 100.0° 0 0 0 0 0 0 0 0 105.0° 0 0 0 0 0 0 0 0 110.0° 0 0 0 0 0 0 0 0 115.0° 0 0 0 0 0 0 0 0 120.0° 0 0 0 0 0 0 0 0 125.0° 0 0 0 0 0 0 0 0 130.0° 0 0 0 0 0 0 0 0 135.0° 0 0 0 0 0 0 0 0 140.0° 0 0 0 0 0 0 0 0 145.0° 0 0 0 0 0 0 0 0 150.0° 0 0 0 0 0 0 0 0 155.0° 0 0 0 0 0 0 0 0 160.0° 0 0 0 0 0 0 0 0 165.0° 0 0 0 0 0 0 0 0 170.0° 0 0 0 0 0 0 0 0 175.0° 0 0 0 0 0 0 0 0 180.0° 0 0 0 0 0 0 0 0

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter (cm) Eavg(lx) Emax(lx)

0.5 17.09 6501.0 9637.0

1.0 34.19 1625.0 2409.0

1.5 51.28 722.4 1071.0

2.0 68.37 406.3 602.3

2.5 85.47 260.1 385.5

3.0 102.56 180.6 267.7

3.5 119.65 132..7 196.7

4.0 136.75 101.6 150.6

4.5 153.84 80.3 119.0

5.0 170.93 65.0 96.4

Angle: 19.4 °. Flux out:158.8 lm

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 51.3 11.08 0-5 51.3 11.08

5-10 107.5 23.25 0-10 158.8 34.33 10-15 95.9 20.75 0-15 254.7 55.08

15-20 66.6 14.41 0-20 321.3 69.49

20-25 45.0 9.74 0-25 366.3 79.23 25-30 29.7 6.41 0-30 396.0 85.64

30-35 18.5 4.01 0-35 414.5 89.65

35-40 11.3 2.45 0-40 425.9 92.10 40-45 7.4 1.60 0-45 433.3 93.70

45-50 5.7 1.23 0-50 439.0 94.93

50-55 5.0 1.09 0-55 444.0 96.02 55-60 4.5 0.97 0-60 448.5 96.99

60-65 3.9 0.84 0-65 452.4 97.83

65-70 3.4 0.73 0-70 455.7 98.56 70-75 2.8 0.61 0-75 458.6 99.17

75-80 2.1 0.45 0-80 460.7 99.62

80-85 1.3 0.28 0-85 461.9 99.90 85-90 0.5 0.10 0-90 462.4 100.00

90-95 0.0 0.00 0-95 462.4 100.00

95-100 0.0 0.00 0-100 462.4 100.00 100-105 0.0 0.00 0-105 462.4 100.00

105-110 0.0 0.00 0-110 462.4 100.00

110-115 0.0 0.00 0-115 462.4 100.00 115-120 0.0 0.00 0-120 462.4 100.00

120-125 0.0 0.00 0-125 462.4 100.00

125-130 0.0 0.00 0-130 462.4 100.00 130-135 0.0 0.00 0-135 462.4 100.00

135-140 0.0 0.00 0-140 462.4 100.00

140-145 0.0 0.00 0-145 462.4 100.00 145-150 0.0 0.00 0-150 462.4 100.00

150-155 0.0 0.00 0-155 462.4 100.00

155-160 0.0 0.00 0-160 462.4 100.00 160-165 0.0 0.00 0-165 462.4 100.00

165-170 0.0 0.00 0-170 462.4 100.00

170-175 0.0 0.00 0-175 462.4 100.00 175-180 0.0 0.00 0-180 462.4 100.00

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ150312502-10A1 Page 12 of 12 The NVLAP Lab Code is 200707-0.

6. Product Photo

***********END OF REPORT***********