IBM System Storage DS8000 for VMware vCenter SiteRecovery Manager 5.xVersion 2.2.1

User Guide

SC27-4232-02

���

Page 2: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

NoteBefore using this document and the product it supports, read the information in “Notices” on page 51.

Edition notice

This publication applies to version 2.2.1 of the IBM System Storage DS8000 for VMware vCenter Site RecoveryManager 5.x and to all subsequent releases and modifications until otherwise indicated in a newer publication.

© Copyright IBM Corporation 2010, 2013.US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contractwith IBM Corp.

Page 3: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Contents

Figures . . . . . . . . . . . . . . . v

About this guide . . . . . . . . . . viiWho should use this guide . . . . . . . . . viiConventions used in this guide . . . . . . . viiRelated documentation . . . . . . . . . . viiGetting information, help, and service . . . . . viiiOrdering publications . . . . . . . . . . viiiSending your comments . . . . . . . . . . viii

Chapter 1. Introduction . . . . . . . . 1Implementing IBM SRA and VMware SRM . . . . 1System requirements. . . . . . . . . . . . 2

Chapter 2. Preparation . . . . . . . . 3Verifying the DS8000 software implementation . . . 3Verify the mirroring configuration . . . . . . . 3Verifying the VMware vCenter SRM installation . . 4

Chapter 3. Installation. . . . . . . . . 7Running the DS8000 SRA installation wizard . . . 7Uninstalling DS8000 SRA software. . . . . . . 10

Chapter 4. Configuration . . . . . . . 15Configuration of DS8000 Remote Copy for SRA . . 16

Setting up preconfigured environments forDS8000 Remote Copy for SRA . . . . . . . 16Setting up non-preconfigured environments forDS8000 Remote Copy for SRA . . . . . . . 18

SRA Configuration for Metro Mirror and GlobalMirror . . . . . . . . . . . . . . . . 18

Setting up preconfigured environments for MetroMirror and Global Mirror. . . . . . . . . 19Setting up non-preconfigured environments forMetro Mirror and Global Mirror . . . . . . 21

SRA Configuration for Metro-Global Mirror . . . 22Commands to register or unregister intermediateDS8000 . . . . . . . . . . . . . . . 22Setting up non-preconfigured environments forMetro-Global Mirror . . . . . . . . . . 23

SRA Configuration for Master Subordinate DS8000s 25Commands to register or unregister subordinateDS8000 . . . . . . . . . . . . . . . 25

Setting up preconfigured environments forMaster Subordinate DS8000 . . . . . . . . 26Setting up non-preconfigured environments forMaster Subordinate DS8000 . . . . . . . . 27

VMware SRM/IBM DS8000 SRA and Tivoli StorageProductivity Center for Replication Coexistence . . 29Setting user privileges for SRA configurations . . . 33

Preconfigured environment . . . . . . . . 33Non-preconfigured environment . . . . . . 33

Chapter 5. Usage . . . . . . . . . . 35Creating the target volumes and Metro/GlobalMirror relationships . . . . . . . . . . . 35Adding Array Manager to VMware Site RecoveryManager . . . . . . . . . . . . . . . 36

SRA Name Filter configuration . . . . . . . 41Test procedures . . . . . . . . . . . . . 43

Running the test procedure on a preconfiguredenvironment . . . . . . . . . . . . . 43Running the test procedure on anon-preconfigured environment . . . . . . 43

Running a failover procedure . . . . . . . . 43Running a reprotect procedure . . . . . . . . 44

Chapter 6. Best Practices. . . . . . . 45Managing datastores and consistency groups . . . 45Troubleshooting . . . . . . . . . . . . . 45

DiscoverArrays failures . . . . . . . . . 45DiscoverDevices failures . . . . . . . . . 46Test failures . . . . . . . . . . . . . 47Recovery failures . . . . . . . . . . . 48“VMFS volume cannot be found” failures . . . 48Reprotect failures . . . . . . . . . . . 49Managing SRM procedures . . . . . . . . 50Collect log files . . . . . . . . . . . . 50

Notices . . . . . . . . . . . . . . 51Trademarks . . . . . . . . . . . . . . 52

Index . . . . . . . . . . . . . . . 55

© Copyright IBM Corp. 2010, 2013 iii

Page 4: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

iv IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 5: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Figures

1. IBM DS8000 Storage System and VMware SRMdisaster recovery . . . . . . . . . . . 1

2. Site Recovery icon on the vSphere clientapplication home page . . . . . . . . . 4

3. Set the language . . . . . . . . . . . 74. The Welcome panel . . . . . . . . . . 85. The License Agreement . . . . . . . . . 86. The Ready to Install panel . . . . . . . . 97. Copying new files status panel . . . . . . 98. InstallShield Wizard Completed panel. . . . 109. Preparing to Install panel . . . . . . . . 11

10. Welcome panel . . . . . . . . . . . 1111. Program Maintenance panel . . . . . . . 1212. Remove the Program panel . . . . . . . 1213. Removing progress panel . . . . . . . . 1314. InstallShield Wizard Complete panel . . . . 1315. Configuration Utility panel . . . . . . . 1516. Preconfigured Metro Mirror scenario . . . . 1717. Preconfigured Global Mirror scenario . . . . 1718. Configuration Utility Window . . . . . . 1919. Pre-Configured option . . . . . . . . . 2020. Non-preconfigured option. . . . . . . . 2121. SRA configurations for Metro-Global Mirror 2422. Subordinate storage configuration . . . . . 2723. Subordinate storage configuration in a

non-pre-configured environment . . . . . 28

24. Tivoli Storage Productivity Center forReplication warning message . . . . . . 30

25. Metro Mirror Failover/Failback with Practice 3126. Metro Mirror Failover/Failback with Practice -

persistent option selected . . . . . . . . 3127. Global Mirror Failover/Failback with Practice 3228. Global Mirror Failover/Failback with Practice -

persistent option selected . . . . . . . . 3329. VMware Virtual Center Server Login . . . . 3630. Site Recovery option on the Home panel 3731. Entering the Remote Virtual Center user name

and password . . . . . . . . . . . . 3732. Summary tab in the Inventory panel . . . . 3833. Array Managers option in the Inventory panel 3834. IBM System DS8000 Adapter as SRA type 3935. Array Manager information . . . . . . . 4036. Add Array Manager Successfully . . . . . 4037. Array Manager information for the remote

DS8000 . . . . . . . . . . . . . . 4138. Configure Name Filter parameter . . . . . 4239. Unable to update array manager. . . . . . 4640. Device cannot be matched to a remote peer

device warning . . . . . . . . . . . 4741. Incomplete Recovery . . . . . . . . . 49

© Copyright IBM Corp. 2010, 2013 v

Page 6: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

vi IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 7: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

About this guide

This guide prepares you to install, configure, and use the IBM® System Storage®

DS8000® Adapter for VMware vCenter Site Recovery Manager 5.x.

Who should use this guideSystem administrators or others who install and use the VMware Site RecoveryManager with IBM System Storage DS8000 can benefit from this guide.

Before installing and using the Storage Replication Adapter for DS8000, you musthave an understanding of the following systems:v Storage area networks (SANs)v DS8000 Metro Mirror/Global Mirror/Metro-Global Mirror copy servicesv Your storage units

For more information on how to use Metro Mirror/Global Mirror/Metro-GlobalMirror copy services, refer to the IBM System Storage DS8000 Introduction andPlanning Guide. The guide can be downloaded from the IBM DS8000 InformationCenter (http://publib.boulder.ibm.com/infocenter/dsichelp/ds8000ic).

Conventions used in this guideThe notices that are used in this publication highlight key information.

Note: These notices provide important tips, guidance, or advice.

Important: These notices provide information or advice that might help you avoidinconvenient or difficult situations.

Attention: These notices indicate possible damage to programs, devices, or data.An attention notice appears before the instruction or situation in which damagecan occur.

Related documentationYou can find additional information and publications related to the IBM SystemStorage DS8000 Adapter for VMware vCenter Site Recovery Manager 5.x at thefollowing websites:v IBM Storage Host Software Solutions Information Center (http://

pic.dhe.ibm.com/infocenter/strhosts/ic)v IBM DS8000 Information Center (http://publib.boulder.ibm.com/infocenter/

dsichelp/ds8000ic)v VMware vCenter Site Recovery Manager Documentation (http://

www.vmware.com/support/pubs/srm_pubs.html)

© Copyright IBM Corp. 2010, 2013 vii

Page 8: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Getting information, help, and serviceIf you need help, service, technical assistance, or seek more information about IBMproducts, you can find various sources to assist you.

You can view the following web sites to get information about IBM products andservices and to find the latest technical information and support:v IBM website (ibm.com®)v IBM Support Portal website (www.ibm.com/storage/support)v IBM Directory of Worldwide Contacts website (www.ibm.com/planetwide)

Ordering publicationsThe IBM Publications Center is a worldwide central repository for IBM productpublications and marketing material.

The IBM Publications Center website (www.ibm.com/shop/publications/order/)offers customized search functions to help you find the publications that you need.Some publications are available for you to view or download at no charge. You canalso order publications. The publications center displays prices in your localcurrency.

Sending your commentsYour feedback is important in helping IBM provide you with the most accurateand highest quality information.

Procedure

To submit any comments about this publication or any other IBM XIV® StorageSystem documentation:v Use the feedback form (http://pic.dhe.ibm.com/infocenter/strhosts/ic/topic/

com.ibm.help.strghosts.doc/icfeedback.htm), orv Send your comments by email to [email protected].

What to do next

For either approach, include the following information:v The publication title and versionv The publication form number (for example, GC27-3920-02)v The page, table, or illustration numbers that you are commenting onv A detailed description of any information that you would like changed

viii IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 9: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 1. Introduction

The IBM System Storage DS8000 Adapter for VMware vCenter Site RecoveryManager (SRM) is a software add-on, used as a Storage Replication Adapter (SRA).The SRA integrates with the SRM solution and enables SRM to run failoverstogether with IBM DS8000 storage systems.

The IBM DS8000 SRA extends SRM capabilities to employ DS8000 replication andmirroring as part of the SRM comprehensive Disaster Recovery Planning solution.By using the IBM DS8000 SRA, VMware administrators can automate the failoverof a DS8000 system at the protected (primary) SRM site to a DS8000 system at arecovery (secondary) SRM site. Immediately upon a failover, the ESX/ESXi serversat the secondary SRM site initiate the replicated datastores on the mirroredvolumes of the secondary DS8000 system. When the primary site is back online,you can run failback from the recovery site to the primary site by clickingReprotect in the SRM.

Implementing IBM SRA and VMware SRMThe IBM DS8000 Storage System can use the DS8000 SRA add-on that works witheach instance of VMware vCenter SRM (protected or recovery).

Figure 1 shows how the IBM DS8000 Storage System is integrated in a typicalVMware SRM disaster recovery solution.

Figure 1. IBM DS8000 Storage System and VMware SRM disaster recovery

© Copyright IBM Corp. 2010, 2013 1

Page 10: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

System requirementsYour system must have the listed prerequisites before you install the IBM DS8000Adapter for VMware vCenter Site Recovery Manager.

Prerequisites:v The DS8000 storage runs on microcode version 6.3.2 (DS8800) or version 7.0 and

later (DS8870).v DS8000s with FlashCopy® and Metro Mirror/Global Mirror feature licenses are

activated at both protected and recovery sites.v Determine whether you want SRA to use space-efficient (SE) volumes during

test failover operations and back up in failover operations. If so, the SE volumefeature must be enabled on the DS8000.

v The user name and password for both protected and recovery site DS8000device’s HMC must be the same.

v IBM System Storage DS8000 Storage Replication Adapter software version 2.2.1must be installed.

v VMware vSphere Virtual Center Server v5.0 or above with Site RecoveryManager 5.x or above plug-in must be installed.

v Make sure that the system's firewall is not blocking the Enterprise Storage ServerNetwork Interface (ESSNI) port 1750 and port 1755. Otherwise, SRA fails withan “Invalid Array ID” message.

v A Fibre Channel (FC) connection must be configured between ESX server andDS8000 storage.

For complete and up-to-date information about the IBM DS8000 Adapter forVMware vCenter Site Recovery Manager compatibility and requirements, see thelatest release notes. You can obtain the latest release notes on the IBM Storage HostSoftware Solutions information center (http://pic.dhe.ibm.com/infocenter/strhosts/ic).

Notes:

1. For information about installing the VMware vCenter Server and Site RecoveryManager plug-in, refer to the VMware Site Recovery Manager Installation andConfiguration Guide.

2. See the relevant VMware documentation for information about how to installthe compatible versions of vCenter Server, Site Recovery Manager, and vSphereClient. Also, see the latest installation and configuration instructions for ESXand ESXi servers.

2 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 11: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 2. Preparation

Depending on your specific site configuration, preparation is required. Before youinstall the IBM DS8000 Adapter for VMware vCenter Site Recovery Manager (IBMDS8000 SRA), review the next three subtopics.

Verifying the DS8000 software implementationYou must verify the DS8000 software implementation before you install anyapplications.

Procedure

Verify the DS8000 software implementation by completing the following steps:1. Verify that the system requirements are met. See “System requirements” on

page 2.2. Create appropriate-sized target volumes on the recovery site DS8000. Create

Metro/Global Mirror relationships between the source and target volumes.3. Create a user on the DS8000 with the appropriate privileges. For SRA

non-preconfigured settings, a user with “Physical Operator” or higher privilegeis needed. For SRA preconfigured settings, a user with “Copy ServicesOperator” or higher privilege is needed.

Note: For information about user privileges, see “Setting user privileges forSRA configurations” on page 33.

Verify the mirroring configurationAll DS8000 systems, volumes, and VMware ESX hosts at both the protected andrecovery sites must be properly connected to their remote counterparts. TheDS8000 systems, volumes, and VMware ESX hosts must then be configured for sitemirroring.

Before you install the IBM DS8000 SRA, verify that the following prerequisites arecompleted:v The local DS8000 system at the protected site has mirroring connectivity with

the target DS8000 system at the recovery site.v The recovery (secondary) ESX/ESXi hosts are defined as DS8000 hosts at the

recovery site.v The recovery ESX/ESXi host ports are FC-zoned (Fibre Channel) with the

DS8000 system at the recovery site and are visible by that DS8000 system.v The name of each DS8000 system is unique in both the protected and recovery

sites.v The storage extent pools that contain the replicated volumes at both sites have

sufficient free capacity for creating the snapshots of all replicated volumesconcurrently.

v Remote mirroring is defined for all DS8000-based volumes that you intend toprotect as part of your Disaster Recovery Plan.

v Your protected (primary) volumes are mapped to the protected ESX hosts.

© Copyright IBM Corp. 2010, 2013 3

Page 12: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: Set HostType to VMWare when you configure host connect on DS8000. Forexample: mkhostconnect -wwname 12341234000A000F -hosttype VMWarehost_1_port_1.

Attention: Confirm with your storage administrator that all the requirements aremet.

Verifying the VMware vCenter SRM installationBefore you install the IBM DS8000 Adapter for VMware vCenter Site RecoveryManager, ensure that the VMware Site Recovery Manager is installed. The VMwareSite Recovery Manager must be accessible at the protected and recovery sites.

Procedure

On the vSphere client application, go to the home page and confirm that the SiteRecovery icon is displayed under “Solutions and Applications.”

Figure 2. Site Recovery icon on the vSphere client application home page

4 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 13: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: For Metro-Global Mirror storage configuration, SRA does not supportfailover to the intermediate site. Install VMware vCenter SRM on the local andremote sites.

Chapter 2. Preparation 5

Page 14: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

6 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 15: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 3. Installation

After you complete the prerequisites that are documented in the upcoming topics,you can install the DS8000 SRA.

Running the DS8000 SRA installation wizardUse the installation wizard to install the IBM System Storage DS8000 StorageReplication Adapter for VMware SRM software.

Before you begin

You must satisfy all of the prerequisites that are listed in “System requirements” onpage 2. For more information, see the IBM System Storage DS8000 StorageReplication Adapter for VMware SRM Release Notes.

Procedure

Complete the following steps to install the IBM System Storage DS8000 StorageReplication Adapter for VMware SRM software on the Windows server:1. Log on to the Windows server as an administrator.2. Download and extract the compressed file archive from the VMware website

(https://my.vmware.com/cn/group/vmware/details?downloadGroup=SRM_SRA&productId=357&rPId=4228).

Important: To download the archive file, you must have a VMware account.3. Double-click the IBMDS8KSRA.exe file from the downloaded compressed file

archive and choose the installation language.

After you select the language, the Welcome panel is displayed. See Figure 4 onpage 8.

Figure 3. Set the language

© Copyright IBM Corp. 2010, 2013 7

Page 16: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

4. Click Next. The License agreement panel is displayed. See Figure 5.

If you do not want to continue with the installation, you can click Cancel.5. Read the license agreement information. Select the I accept the terms of the

license agreement choice and click Next. The Ready to Install the Programpanel is displayed (see Figure 6 on page 9).

Figure 4. The Welcome panel

Figure 5. The License Agreement

8 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 17: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

6. Click Install. After you click Install, the installation wizard shows the status ofthe files that are being copied. See Figure 7.

7. Click Finish when the installation process completes. See Figure 8 on page 10.

Figure 6. The Ready to Install panel

Figure 7. Copying new files status panel

Chapter 3. Installation 9

Page 18: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: DS8000 SRA is installed under the SRM folder.v For SRM 5.0, the installation directory is C:\Program Files

(x86)\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBMDS8000.

v For SRM 5.1 and later, the installation directory is C:\ProgramFiles\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBMDS8000.

Uninstalling DS8000 SRA softwareYou can uninstall the IBM System Storage DS8000 Storage Replication Adaptersoftware by kicking off the installation file (IBMDS8KSRA.exe).

Procedure

Complete the following steps to uninstall the software:1. Log on to the Windows server as an administrator.2. Locate the IBMDS8KSRA.exe file and double-click it. The “Preparing to Install”

panel is displayed. See Figure 9 on page 11.

Figure 8. InstallShield Wizard Completed panel

10 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 19: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

3. Click Next on the Welcome page. See Figure 10.

4. Select Remove on the Program Maintenance panel and click Next. SeeFigure 11 on page 12.

Figure 9. Preparing to Install panel

Figure 10. Welcome panel

Chapter 3. Installation 11

Page 20: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

5. Click Remove to confirm the uninstallation. See Figure 12.

The Removing progress panel is displayed. See Figure 13 on page 13.

Figure 11. Program Maintenance panel

Figure 12. Remove the Program panel

12 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 21: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

6. Click Finish from the InstallShield Wizard Completed panel. See Figure 14. Ifnecessary, you are prompted to restart the system.

Figure 13. Removing progress panel

Figure 14. InstallShield Wizard Complete panel

Chapter 3. Installation 13

Page 22: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

14 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 23: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 4. Configuration

IBM DS8000 SRA works with Metro Mirror, Global Mirror (with or without masterand subordinate), Metro-Global Mirror, and IBM Tivoli Storage Productivity Centerfor Replication Coexistence.

A shortcut named IBMDS8KSRAUtil.exe is created on the desktop during the DS8000SRA installation.

Important: The configuration utility is used to configure the SRA. Theconfiguration takes effect on the site where the utility runs.

Double-clicking the shortcut brings up the Utility panel. See Figure 15.

The Utility must be configured before you configure SRM with the array.

Preconfigured/Non-preconfigured

The environment can be a preconfigured environment or a non-preconfiguredenvironment. A preconfigured environment is one where you create the backuptarget volumes and map the volumes to the ESX servers at the recovery site, in

Figure 15. Configuration Utility panel

© Copyright IBM Corp. 2010, 2013 15

Page 24: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

advance. A non-preconfigured environment is one where the SRA creates and mapssnapshot volumes during test failover and backup target volume operations.

Note: If preconfigured/non-preconfigured are switched by the configurationutility, rescan SRA in SRM on both the protected and the recovery site.

DS8000 Command Timeout (sec)

The DS8000 Command Timeout specifies the maximum time, in seconds, to waitfor a required state of volume, command results, FlashCopy, or remote copy. Thewait is after certain DS8000 commands, or to wait for command result. Forexample:v SRA waits for the volume initialization to be completed before it establishes a

FlashCopy relationship.v After a Metro Mirror copy relationship is resumed, SRA waits for the secondary

full duplex state.v During a reprotect process of Global Mirror, SRA waits for the first pass

completion of the remote copy that is established by SRA.v When ESSNI functional code does not accept the command due to being busy,

SRA waits and resubmits the command.

If the time SRA waited exceeds the configured maximum timeout setting, SRA failsdue to a timeout exception. If the value is empty or 0, SRA waits until the requiredstate is met or the issued command result is returned. The user can keep the boxempty as the default value.

For more configuration fields, see “Configuration of DS8000 Remote Copy forSRA.”

Configuration of DS8000 Remote Copy for SRAAlong with the regular remote copy configuration on DS8000, some specialconfiguration is required for SRA defined mode.

Setting up preconfigured environments for DS8000 RemoteCopy for SRA

In the Pre-Configured mode, SRA does not create a volume or FlashCopy. It alsodoes not attach or detach the volume to or from the host.

Procedure1. Create an equal number of FlashCopy (target) volumes on both the production

and the recovery site DS8000.2. Complete this step according to the scenario:

v For a Metro Mirror scenario, create the following items:a. A background copy. The incremental FlashCopy maps, with the volumes

that were created in step 1 as the FlashCopy target volume.b. The Metro Mirror copy source and target volumes, as the FlashCopy

source volumes.

Note: See the flow chart in Figure 16 on page 17 showing how apreconfigured Metro Mirror scenario is configured.

16 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 25: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

v For the Global Mirror scenario, create the following items:a. A background copy FlashCopy map, with the volumes that were created

in step 1 on page 16 as the FlashCopy target volume.b. The Global Mirror source and target volumes as the FlashCopy source

volumes.c. The Global Mirror FlashCopy between the Remote Mirror source volume

and the newly created FlashCopy target volume.

Note: See the flow chart in Figure 17 showing how a preconfigured GlobalMirror scenario is configured.

3. Map the Remote Copy target and the FlashCopy target volumes to the ESXservers. The newly created FlashCopy target volumes are used as test volumesduring the test procedure. The RemoteCopy target volumes are used as theproduction volumes during the failover procedure.

Note: The preconfigured FlashCopy relationship is synchronized byreestablishing the original FlashCopy relationship. Four FlashCopy options canbe restored during the reestablishment process:v persistent

v record

v nocopy

v tgtse

Important:

Figure 16. Preconfigured Metro Mirror scenario

Figure 17. Preconfigured Global Mirror scenario

Chapter 4. Configuration 17

Page 26: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

a. For Global Mirror in a preconfigured environment, ensure that no session orGlobal Mirror exists on the LSS of the Global Mirror target volume for theinitial state.

b. Reserve the session ID, used by the LSS of the remote copy source volume,on the target DS8000.

Setting up non-preconfigured environments for DS8000Remote Copy for SRA

In the non-preconfigured mode, SRA creates volumes and FlashCopy and canattach or detach volumes to or from the host.

Before you set up a non-preconfigured environment, make sure that the remotecopy target volume is unmapped from ESX servers for the initial state.

SRA creates volumes and FlashCopy, and can attach volumes to or from the hostwhen test failover is run. SRA detaches the volumes that are created during testfailover from the host, and deletes the FlashCopy and the volumes during testfailover clean-up.

Important:

v If Global Mirror/Metro-Global Mirror is picked in a non-preconfiguredenvironment, make sure that no session or Global Mirror exists on the LSS of theGlobal Mirror target volume for the initial state.

v If Metro-Global Mirror is picked for the non-preconfigured environment, makesure that no session or Global Mirror exists on the LSS of the Metro Mirrorsource volume for the initial state.

v Reserve the session ID, used by the LSS of the remote copy source volume, onthe target DS8000.

SRA Configuration for Metro Mirror and Global MirrorVMware SRM 5.x provides planned failover and disaster recovery.

Important: The configuration utility must be run on both the protected site andthe recovery site. The Pre-Configured setting (checked or not checked) needs to beconsistent on both sites.

VMware SRM 5.x provides two kinds of recoveries:v Planned failoverv Disaster recovery

Double-click the IBMDS8KSRAUtil.exe shortcut on the desktop to access the SRMConfiguration Utility (see Figure 18 on page 19). In both recovery scenarios, theuser can opt to back up the remote copy target volumes. If Pre-Configured is notchecked, check “Backup Target Volume” and set the appropriate Backup ExtPoolID. The ID instructs the SRA to create FlashCopy backups of the remote copytarget volumes.

18 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 27: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Support Relationship Type

The Support Relationship Type specifies the types of relationships that the SRAoperates on. The default value is “Both Metro Mirror and Global Mirror,” whichmeans SRA discovers all the Metro Mirror and Global Mirror relationships betweenthe protected site and the recovery site.

Notes:

v SRA creates volumes by using the extent pool of the remote copy target volumewhen any of the following situations are true:– Test extent pool parity is inconsistent with the LSS of remote copy target

volume– Backup extent pool parity is inconsistent with the LSS of remote copy target

volume– Test or backup extent pool parity is empty

v If the SRA does not back up the target volumes, check the backups on thestorage or check the messages in the SRM log file.

Setting up preconfigured environments for Metro Mirror andGlobal Mirror

If the Pre-Configured option is checked, some configuration is needed before SRAcan function properly.

Figure 18. Configuration Utility Window

Chapter 4. Configuration 19

Page 28: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Procedure

Double-click the IBMDS8KSRAUtil.exe shortcut on the desktop to access the SRMConfiguration Utility (see Figure 19).1. Check the Pre-Configured option.

Notes:

v The Test ExtPool ID (Px), Backup Target Volume, Backup ExtPool ID (Px),and SpaceEfficient Mode options are unavailable if the Pre-Configuredoption is checked.

v The DS8000 Command Timeout (sec) option determines how long you wantthe process to run.

2. Select the Support Relationship Type according to the user requirement.3. Check TPC-R if you use SRA integrated with Tivoli® Storage Productivity

Center for Replication.4. Click OK to confirm the new selections or click Cancel to leave the selections

unchanged. To confirm or change the options, restart the configuration utilityby double-clicking the shortcut. The current selections are shown.

Note: FlashCopy (target) volumes are resynchronized during failover when theTPC-R option is not checked.

Figure 19. Pre-Configured option

20 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 29: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Setting up non-preconfigured environments for Metro Mirrorand Global Mirror

If the Pre-Configured option is not checked, some SRA configuration is neededbefore SRA can function properly.

Procedure

Complete the following steps to set up a non-preconfigured environment:1. Double-click the IBMDS8KSRAUtil.exe shortcut on the desktop to access the SRM

Configuration Utility (see Figure 20).

2. Define the appropriate configuration settings:

Test ExtPool ID (Px)Specifies which Extent Pool ID on the DS8000 site is used to createFlashCopy (target) volumes during the test recovery operation. Theformat of input value is Px, for example, P1.

Backup Target VolumeInstructs SRA to back up the target volume during recovery. BackupExtPool ID (Px) must be set if this option is checked.

Backup ExtPool ID (Px)If Backup Target Volume is checked, this field must be set for SRA to

Figure 20. Non-preconfigured option

Chapter 4. Configuration 21

Page 30: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

create the FlashCopy (target) volume to back up the remote copy targetvolume. The format of input value is Px, for example, P1.

Space Efficient ModeInstructs SRA to create a SE volume during test failover or backuptarget volume process. SRA creates a track space-efficient (TSE) volumewith this option. If the option is not checked, a standard volume iscreated.

3. Click OK to confirm the new selections or click Cancel to leave the selectionsunchanged. To confirm or change the options, restart the configuration utilityby double-clicking the shortcut. The saved selections are shown when yourestart the configuration utility.

Notes:

v If Backup Target Volume is checked, you must remove the FlashCopy afterthe copy progress finishes. Otherwise, it causes the second test failover, orfailover on the same site failure because of an extra preconfigured FlashCopyin a non-preconfigured environment.

v The DS8000 Command Timeout (sec) option determines how long you wantthe process to run.

SRA Configuration for Metro-Global MirrorSRA supports only the non-preconfigured setting for Metro-Global Mirror.

If the remote copy relationship is configured as Metro-Global Mirror, you mustprovide information about the intermediate DS8000 site.

Notes about Metro-Global Mirror:

v SRA does not support failover to the intermediate site.v The initial direction is Site A (protected site) > Site B (intermediate site) > Site

C (recovery site). After the first reprotect procedure to the initial direction, thedirection changes to Global Mirror: Site C (protected site) > Site A (recoverysite). After the second reprotect procedure, the direction returns to Metro-GlobalMirror: Site A > Site B > Site C.

Commands to register or unregister intermediate DS8000Use the RegInterSite command to register, unregister, and show help information.

Note: For SRM 5.1 and later, the SRA installation directory can be \ProgramFiles\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBM DS8000\

Register intermediate DS80001. In the open command line prompt, change the current directory to an SRA

installation directory. For example: C:\>cd "\Program Files(x86)\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBMDS8000\"

2. Issue the following example command to register the intermediate site DS8000:jre\bin\java.exe -cp lib\DS8K_Java_Client.jarRegInterSite 9.11.108.28 dsuser dspassword IBM.2107-75H0301 add

Where dsuser is the username and dspassword is the password. The output thatis returned appears similar to the following example output:Add 9.11.108.28 successfully. Pre-Configured is set to false.

22 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 31: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: SRA supports only a non-preconfigured setting for Metro-Global Mirror. So,the command shows that “Pre-Configured” is being set to false. If you are usingthe preconfigured setting on the storage, clear the setting.

Unregister intermediate DS8000

To remove intermediate site information, issue the following example commandfrom the SRA installation directory:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegInterSite 9.11.108.28 delete

The output that is returned appears similar to the following example output:Delete 9.11.108.28 successfully.

Show help information

To show the help menu, issue the following command from the SRA installationdirectory:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegInterSite

The output that is returned appears similar to the following example output:Usage:RegInterSite [HMC IP Address] [HMC username] [HMC password] [Machine Serial] addRegInterSite delete

Setting up non-preconfigured environments for Metro-GlobalMirror

Configure non-preconfigured environments for Metro-Global Mirroring.

Procedure

Complete the following steps to set up non-preconfigured environments forMetro-Global Mirror:1. Click IBMDS8KUtility to set up SRA configurations for Metro-Global Mirror

(see Figure 21 on page 24). The Metro-Global Mirror message is displayed inthe panel.

Chapter 4. Configuration 23

Page 32: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Test ExtPool ID (Px)Specifies which Extent Pool ID on the DS8000 site is used to createFlashCopy (target) volumes during test recovery operations. The formatof input value is Px, for example, P1.

Backup Target VolumeInstructs SRA to back up the target volume during recovery. BackupExtPool ID (Px) must be set if this option is selected.

Backup ExtPool ID (Px)If Backup Target Volume is checked, this field must be set for SRA tocreate the FlashCopy (target) volume to back up the remote copy targetvolume. The format of input value is Px, for example, P1.

Space Efficient ModeInstructs SRA to create an SE volume when test failover or a backuptarget volume is specified. SRA always creates a TSE volume with thisoption. If the option is not checked, a standard volume is created.

2. Click OK to confirm the new selections or click Cancel to leave the selectionsunchanged. To confirm or change the options, restart the configuration utilityby double-clicking the shortcut. The saved selections are shown.

Notes:

v Metro-Global Mirror is a special configuration to Metro Mirror and GlobalMirror, so you cannot select Support Relationship Type for this case.

Figure 21. SRA configurations for Metro-Global Mirror

24 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 33: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

v The utility detects the intermediate site setting and shows “Metro GlobalMirror is configured.” on the GUI.

v SRA does not support TPC-R for Metro-Global Mirror, so it is disabled.v If Backup Target Volume is checked, you must remove the FlashCopy after

the copy progress completes. Otherwise, the FlashCopy causes the secondtest failover or failover on the same site failure because of an extrapreconfigured FlashCopy in a non-preconfigured environment.

v The DS8000 Command Timeout (sec) option determines how long you wantthe process to run.

SRA Configuration for Master Subordinate DS8000sSRA supports the Global Mirror session, which crosses DS8000s. The subordinateDS8000s need to be registered into SRA. The DS8000s’ information, which isentered in SRM, is “master DS8000” on the protected site and the recovery site.The authentication information for all master and subordinate DS8000s must be thesame for SRA.

Commands to register or unregister subordinate DS8000Issue the RegSubStorage command from the SRA installation directory to registeror unregister subordinate DS8000s.

Note: For SRM 5.1 and later, the SRA installation directory can be \Program Files(x86)\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBM DS8000\

To register local or peer subordinate DS8000s

From the SRA installation directory, issue the following command to register localsubordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jarRegSubStorage add local IBM.2107-75H0301/9.11.108.28

Issue the following command to register peer subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jarRegSubStorage add peer IBM.2107-75LH331/9.11.109.142

To unregister local or peer subordinate DS8000s

From the SRA installation directory, issue the following command to unregisterlocal subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jarRegSubStorage delete local IBM.2107-75H0301/9.11.108.28

Issue the following command to unregister peer subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jarRegSubStorage delete peer IBM.2107-75LH331/9.11.109.142

To list all registered subordinate DS8000s

From the SRA installation directory, issue the following command to list allregistered subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegSubStorage list

Chapter 4. Configuration 25

Page 34: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

To list local or peer registered subordinate DS8000s

From the SRA installation directory, issue the following command to list all localregistered subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegSubStorage list local

Issue the following command to list peer registered subordinate DS8000s:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegSubStorage list peer

To show help information

From the SRA installation directory, issue the following command to show helpinformation:jre\bin\java.exe -cp lib\DS8K_Java_Client.jar RegSubStorage

The information is delivered in this format:Usage:RegSubStorage [list] <local | peer>RegSubStorage [add | delete] [local | peer] [Machine Serial/HMC IP Address]eg. Add peer subordinate storage:RegSubStorage add peer IBM.2107-1234567/192.168.1.1eg. delete peer subordinate storage:RegSubStorage delete peer IBM.2107-1234567/192.168.1.1

Setting up preconfigured environments for MasterSubordinate DS8000

If you select the Pre-Configured option, some configuration is needed before SRAcan function properly.

Procedure

Click the IBMDS8KUtility to set up the Master Subordinate DS8000 (see Figure 22on page 27). The subordinate storage message is displayed in the panel.

26 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 35: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

1. Select the Pre-Configured option. Select TPC-R if you use SRA integrated withTivoli Storage Productivity Center for Replication.

2. Click OK to confirm the new selections or click Cancel to leave the selectionsunchanged. To confirm or change the options, restart the configuration utilityby double-clicking the shortcut. The saved selections are shown.

Notes:

v When you select the Pre-Configured option, the Test ExtPool ID (Px),Backup Target Volume, Backup ExtPool ID (Px), and SpaceEfficient Modeoptions are unavailable.

v FlashCopy (target) volumes are resynchronized during failover when theTPC-R option is not checked.

v Because Master Subordinate DS8000 is for Global Mirror only, you cannotselect Support Relationship Type.

v The DS8000 Command Timeout (sec) option determines how long you wantthe process to run.

Setting up non-preconfigured environments for MasterSubordinate DS8000

If the Pre-Configured option is not selected, some SRA settings need to be definedso that SRA can function properly.

Figure 22. Subordinate storage configuration

Chapter 4. Configuration 27

Page 36: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Procedure

Click IBMDS8KUtility to open the DS8000 SRA for VMware SRM ConfigurationUtility (see Figure 23).1. Select the configuration settings that are appropriate for non-preconfigured

environments for Master Subordinate DS8000s.

Test ExtPool ID (Px)Specifies which Extent Pool ID on the DS8000 site is used to createFlashCopy (target) volumes during test recovery operations. The inputformat is Px, for example, P1. This setting applies for all thesubordinate storage. Ensure that there is enough space in the extentpool.

Backup Target VolumeInstructs SRA to back up the target volumes during recovery. BackupExtPool ID (Px) must be set if this option is selected. If this option isnot selected, the Backup ExtPool ID (Px) option is unavailable.

Backup ExtPool ID (Px)If Backup Target Volume is selected, this field must be set for SRA tocreate the FlashCopy (target) volumes to back up the remote copytarget volume. The input format is Px, for example, P1. This settingapplies for all the subordinate storage. Ensure that there is enoughspace in the extent pool.

Figure 23. Subordinate storage configuration in a non-pre-configured environment

28 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 37: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Space Efficient ModeInstructs SRA to create a SE volume when test failover or backup targetvolumes is specified. SRA always creates a TSE volume with thisoption. If the option is not checked, a standard volume is created.

DS8000 Command Timeout (sec)Determines how long you want the process to run.

2. Click OK to confirm the new selections or click Cancel to leave the selectionsunchanged. To confirm or change the options, restart the configuration utilityby double-clicking the shortcut. The saved selections are shown.

Notes:

v If Backup Target Volume is checked, you must remove the FlashCopy afterthe copy progress completes. Otherwise, the second test failover occurs orfailover occurs on the same site failure because of an extra preconfiguredFlashCopy in a non-preconfigured environment.

v If you configured both intermediate storage and subordinate storage withcommands, SRA treats it as Metro-Global Mirror only.

VMware SRM/IBM DS8000 SRA and Tivoli Storage Productivity Centerfor Replication Coexistence

If the environment mandates that you use VMware SRM with Tivoli StorageProductivity Center for Replication, configure the SRA for the pre-configuredenvironment (by using IBMDS8000SRAUtil.exe).

When initiated from SRM, the test failover operation (or practice test) worksindependently of Tivoli Storage Productivity Center for Replication. Therefore, SRAdoes not try to detect an existing Tivoli Storage Productivity Center for Replicationinstallation in the environment. The test failover task on SRM and practice tests onTivoli Storage Productivity Center for Replication must be scheduled and run atdifferent times if both software works on the same Global Mirror session. If theenvironment is set up such that Tivoli Storage Productivity Center for Replicationand SRM work on different Global Mirror sessions, then the restriction does notapply.

For a real failover (Recovery), if Tivoli Storage Productivity Center for Replicationand SRM must co-exist and work on the same Global Mirror session, then TivoliStorage Productivity Center for Replication recovery must be initiated first. Afterthe user confirms the successful recovery of volumes by Tivoli Storage ProductivityCenter for Replication, the SRM failover can be initiated.

The TPC-R option is enabled when SRA is set to Pre-Configured. Click the TPC-Rcheck box to enable Tivoli Storage Productivity Center for Replication support. Awarning message box is displayed. See Figure 24 on page 30.

Chapter 4. Configuration 29

Page 38: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Notes:

1. You must set Tivoli Storage Productivity Center for Replication to run recoveryor reprotect operations (only for Metro Mirror with Tivoli Storage ProductivityCenter for Replication) before corresponding SRM operations; otherwise theSRA actions fail.

2. Tivoli Storage Productivity Center for Replication mode does not supportreprotect operation for Global Mirror.

SRA can integrate with Tivoli Storage Productivity Center for Replication witheither two of these session types:v Metro Mirror Failover/Failback with Practice. SRA supports recovery and

reprotects. See Figure 25 on page 31 and Figure 26 on page 31.v Global Mirror Failover/Failback with Practice. SRA supports recovery only. See

Figure 27 on page 32 and Figure 28 on page 33.

Figure 24. Tivoli Storage Productivity Center for Replication warning message

30 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 39: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: For Metro Mirror Failover/Failback with Practice - persistent option,select Persistent for “Data Studio FlashCopy Options for Role Pair H2-I2” whenyou set up session properties.

Figure 25. Metro Mirror Failover/Failback with Practice

Figure 26. Metro Mirror Failover/Failback with Practice - persistent option selected

Chapter 4. Configuration 31

Page 40: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: For Global Mirror Failover/Failback with Practice - persistent option,select Persistent for “Data Studio FlashCopy Options for Role Pair H2-I2” whenyou set up session properties.

Figure 27. Global Mirror Failover/Failback with Practice

32 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 41: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Setting user privileges for SRA configurationsSetting the user privileges for SRA differs, depending on whether you have apreconfigured environment or a non-preconfigured environment.

Preconfigured environmentHaving Copy Services Operator privilege is sufficient to create the neededvolumes and map them to the recovery site's ESX servers in advance.

Non-preconfigured environmentIf the Pre-Configured box is left cleared in the configuration utility, a PhysicalOperator or higher privilege is necessary for SRA to complete the following tasks:v Create the snapshot volumes and map or unmap the volumes to the ESX servers

at the recovery site.v Run test recovery operations.

Figure 28. Global Mirror Failover/Failback with Practice - persistent option selected

Chapter 4. Configuration 33

Page 42: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

34 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 43: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 5. Usage

Use the IBM DS8000 Adapter for VMware vCenter Site Recovery Manager to rundependable Disaster Recovery Planning and protect VMware sites with theirDS8000-based datastores.

Creating the target volumes and Metro/Global Mirror relationshipsYou must create an equal number of target volumes (for Metro Mirror targets) tosource volumes, and an extra set of volumes for FlashCopy targets for GlobalMirror set up, on the recovery site DS8000, to source volumes.

Before you begin

Important: When you create volumes on the recovery site, make sure that theDS8000 has enough free space for volume creation during test failover operations.If the recovery DS8000 has SE volume support that is enabled, the SRA creates TSEFlashCopy target volumes during test failover operations. Before the SRA cancreate SE volumes, sufficient SE storage must first be configured on the array. Formore information about SE storage configuration and SE concepts in general, seeIBM DS8000 Thin Provisioning.

Procedure

Create Metro/Global Mirror relationships between the source and target volumes.Do not map the Metro/Global Mirror target volumes to the ESX servers on therecovery site in a non-preconfigured environment. The reason is because themapping process is automated by the SRA for failover and test failover operations.For more information about Metro Mirror/Global Mirror Copy Services, see IBMSystem Storage DS8000: Copy Services in Open Environments.

Important:

1. When you create Global Mirror relationships with SE volumes, make sure youuse ESE as your Global Mirror target volumes; not TSE volumes.

2. Before you use the DS8000 Storage Replication Adapter, ensure the followingconfiguration settings:v The Metro Mirror relationships on the recovery site are in “Target Full

Duplex” statusv For Global Mirror relationships “First Pass” status on a protected site is

“True”v Consistency Groups are forming at the set intervals

If SE volume is not enabled for SRA configuration, the SRA creates fully allocatedvolumes during test failover operations. Fully allocated volumes must beinitialized before they can be used as FlashCopy targets. This action might takeseveral minutes, depending on the size of the newly created volume. Toaccommodate the timing, the user must modify the DS8000 Command Timeout(sec) of IBMDS8KSRAUtil.exe or leave the parameter empty to make SRA wait untilthe newly created volume is ready.You might also want to change the “storage.commandTimeout” value of VMwareSRM.

© Copyright IBM Corp. 2010, 2013 35

Page 44: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Adding Array Manager to VMware Site Recovery ManagerTo add arrays to the VMware Site Recovery Manager, complete the followingprocedure.

Procedure1. Log on to the VMware Virtual Center Server. See Figure 29.

2. Click Site Recovery on the Home panel. See Figure 30 on page 37.

Figure 29. VMware Virtual Center Server Login

36 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 45: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

3. Enter the Remote Virtual Center user name and password, when prompted,and click OK. See Figure 31.

4. Ensure that the local and remote sites are connected. Select the local site andconfirm the connection by clicking the Summary tab in the Inventory panel.See Figure 32 on page 38.

Figure 30. Site Recovery option on the Home panel

Figure 31. Entering the Remote Virtual Center user name and password

Chapter 5. Usage 37

Page 46: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

5. Click the Array Managers option on the Inventory panel and select Summary.See Figure 33.

6. Select the local site on the Inventory panel and click Add Array Manager.7. Enter the name for the local DS8000 and select IBM System DS8000 Adapter

as SRA type, then click Next.8. Enter the array manager information in the Add Array Manager panel. See

Figure 34 on page 39.

Figure 32. Summary tab in the Inventory panel

Figure 33. Array Managers option in the Inventory panel

38 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 47: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

First Management IP Address/HostnameEnter the IP address of the protected site DS8000 device’s HardwareManagement Console (HMC). For example, 192.168.15.3 The addresscan either be an IP address or a fully qualified domain name.

Second Management IP Address/HostnameEnter the IP address of the recovery site array’s HMC. For example,192.168.17.2 The address can either be an IP address or a fullyqualified domain name.

Note: IBM System Storage DS8000 Storage Replication Adapter workswith only one of the HMCs (in dual HMC environments).

Name FilterEnter a comma-separated list of volume names or session ID prefixesfor a specific discovery (for example, cnLun,10,usLun). Leave theparameter empty for full discovery.

Notes:

v Use \ to represent the comma in the volume name or session id. Forexample, cnLun\10\usLun.

v See “SRA Name Filter configuration” on page 41 for moreinformation.

User nameEnter the user name that is configured for DS8000 device’s HMC.

PasswordEnter the password for the DS8000 device’s HMC.

Note: The user name and password for protected and recovery site DS8000device’s HMC must be the same.

9. Enter the connection information for the array.10. Click Next. SRM discovers the DS8000 device at the specified IP address.

Figure 34. IBM System DS8000 Adapter as SRA type

Chapter 5. Usage 39

Page 48: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

11. Click Finish. See Figure 35.

12. Select the remote site on the Inventory panel and click Add Array Manager.

13. Enter the name for the remote DS8000 and click Next.14. Enter the Array Manager information for the remote DS8000 on the Add

Array Manager panel.

Figure 35. Array Manager information

Figure 36. Add Array Manager Successfully

40 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 49: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Note: The IP address is reversed to the peer site.15. Click Next to confirm the successful addition of the Array Manager.16. Click Finish.17. Select the local array on the Inventory panel and select the Array Pairs tab.18. Click Enable in the Actions column to pair the local and remote sites together.

The device discovery and datastore computation process is initiated. If thepairing is successful, the Status column shows Enabled. The discovereddevices information is available under the Devices tab. If new replicateddevices must be discovered, click Refresh.

Important: All DS8000-replicated volumes that participate in SRM and belongto the same Remote Mirror Consistency Group are shown under a single LocalConsistency Group in SRM. Take extra care while you add replicated volumesto Consistency Groups. Add all volumes that are used by a single virtualmachine (VM) or an application on the VM to the same Consistency Group.

SRA Name Filter configurationYou can use the Name Filter parameter to provide replicated device filtering. Bydefault, the discoverDevices command returns the list of all replicated devices fora pair of replicated storage arrays. This list can be long, so you might want to limitthe device discovery to the subset of devices that are managed by SRM.

DS8000 SRA defines one Name Filter parameter to specify a filter for devicediscovery. The parameter can be used to limit the discovery to replicated volumesor session IDs whose names begin with the specified string. The parameter filtersMetro Mirror remote copies by source or target volume names and filters GlobalMirror or Metro-Global Mirror remote copies by session IDs.

For full discovery, leave the parameter empty. The parameter can be acomma-separated list of the prefix of the volume name or session ID for specificdiscovery (Example: cnLun,10,usLun).

Notes:

Figure 37. Array Manager information for the remote DS8000

Chapter 5. Usage 41

Page 50: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

v Use \, to represent the comma in the volume name or session id.For example, cnLun\10\usLun.

v When SRA is set to Pre-Configured and the TPC-R option is enabled, check theremote copy session IDs and volume names on the DS8000 storage before youset up the Name Filter. It is suggested that you leave the Name Filter empty inthe Tivoli Storage Productivity Center for Replication scenario.

v Prefixes for session IDs are the same on both the protected and the recovery site.Session ID x can be set up as 0x if x is only one character.For Example: Session ID 9 can be set up as 09; Session ID E can be set up as 0E.

v Prefixes for the volume name can be different for each site, but the prefixes mustbe paired on both sites.For Example: The protected site volume name is pro_volumeA and on therecovery site it is mapped to rec_volumeB. Then, in the Name Filter of theprotected site, enter prefix pro. On the recovery site, enter rec.

Configure the Name Filter parameter when adding an array manager to theVMware Site Recovery Manager. See Figure 38.

Figure 38. Configure Name Filter parameter

42 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 51: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Test proceduresDepending on the SRA configuration, it might be necessary to perform extra tasksfor the test procedure to work.

Attention: If you encounter a failure during the test procedure, check if theremote copy status is the same as the original state. If NOT, manually restore theremote copy status back to its original state after cleanup procedures.

For troubleshooting information, see “Test failures” on page 47.

Running the test procedure on a preconfigured environmentThe IBM DS8000 SRA completely automates the test procedure.

During the test procedure, the preconfigured FlashCopy target volumes areresynchronized.

Ensure that all of the steps that are outlined in “Setting up preconfiguredenvironments for DS8000 Remote Copy for SRA” on page 16 are completed.

Running the test procedure on a non-preconfiguredenvironment

The IBM DS8000 SRA completely automates the test procedure.

During this procedure, the SRA creates SE FlashCopy target volumes if the SEvolume support feature is enabled and SE storage is defined on the storage array isspecified. If the recovery site DS8000 does not have SE support that is enabled, theSRA creates fully allocated volumes for test failover operations. The onlyprerequisite this procedure needs, from the Storage Replication Adapter’sperspective, is to have enough free capacity available in one of the extent pools toaccommodate the FlashCopy target volumes.

During the cleanup procedure, the FlashCopy relationships and FlashCopy targetvolumes that are created during the test procedure are deleted.

Prerequisites for the SRA Test procedurev Have enough free space available on the Extent Pool.v Complete all the steps that are outlined in “Setting up non-preconfigured

environments for DS8000 Remote Copy for SRA” on page 18.

Running a failover procedureThe IBM DS8000 SRA completely automates the failover procedure.

DS8000 SRA does a failover of the Metro/Global Mirror/Metro-Global Mirrortarget volumes to the recovery site during a failover operation. The Metro/GlobalMirror/Metro-Global Mirror target volumes are promoted to the ESX Server asproduction volumes.

During an SRA preconfigured failover procedure, the preconfigured FlashCopy isresynchronized.

Chapter 5. Usage 43

Page 52: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Prerequisites for the SRA Failover procedurev For preconfigured environments, complete all the steps that are outlined in

“Setting up preconfigured environments for DS8000 Remote Copy for SRA” onpage 16.

v For non-preconfigured environments, complete all the steps that are outlined in“Setting up non-preconfigured environments for DS8000 Remote Copy for SRA”on page 18.

Running a reprotect procedureThe IBM DS8000 SRA completely automates the reprotect procedure.

Before you run the Reprotect action, refresh the Devices panel of the SRM ArrayManagers to ensure that no error messages occur.

During the Reprotect procedure, the Metro/Global Mirror/Metro-Global Mirrordirection changes from the original recovery site to the original protected site, andthe mirroring action is resumed.

Notes:

v Original protected volumes are detached from the host during the reprotectprocedure for non-preconfigured scenarios.

v For Metro-Global Mirror, the initial direction is Site A (protected site) > Site B(intermediate site) > Site C (recovery site). After the first reprotect procedure toinitial direction, the direction is changed to Global Mirror: Site C (protected site)> Site A (recovery site). After the second reprotect procedure, the direction willbe changed back to Metro-Global Mirror: Site A > Site B > Site C.

Prerequisites for the SRA reprotect procedurev For non-preconfigured Global Mirror/Metro-Global Mirror, ensure that there is

enough free space available on the Extent Pool of the original remote copysource volume.

v For preconfigured environments, complete all the steps that are outlined in“Setting up preconfigured environments for DS8000 Remote Copy for SRA” onpage 16.

v For non-preconfigured environments, complete all the steps that are outlined in“Setting up non-preconfigured environments for DS8000 Remote Copy for SRA”on page 18.

44 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 53: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Chapter 6. Best Practices

Follow the best practice guidelines while you configure and use the IBM SystemStorage DS8000 Adapter for VMware vCenter Site Recovery Manager 5.x.

Managing datastores and consistency groupsFollow these best practice guidelines while you are working with datastores andconsistency groups:v The datastores of one virtual machine (VM) should be in the same consistency

group.v The datastore of the VM and the raw disk in the VM should be in the same

consistency group.v You must have administrator privileges to install the SRM.v Set appropriate timeout and rescan values in the SRM for recovery of many

VMs.

TroubleshootingWhen an error occurs, check the status of the DS8000s, ESX Servers, vCenters, andSANs.

DiscoverArrays failuresVerify the following items when you encounter failure during Array Manageroperations.v Check that the IP address is correct and in the correct format. For example, the

format can resemble: 192.168.15.3.v Check that the user name and password are correct.v Check to see if the DS8000s are paired.

Example:

Symptom: Unable to update array manager. See Figure 39 on page 46.

© Copyright IBM Corp. 2010, 2013 45

Page 54: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Possible root cause and solution: The IP address, user name, or password isincorrect. Check and correct the IP address, user name, or password.

DiscoverDevices failuresVerify the following items when you encounter failure during Devices for EnabledArray Pairs operation.v Ensure that the Metro Mirror relationships’ status on the recovery site are

“Target Full Duplex.”v Ensure that Global Mirror relationships’ “First Pass” status is “True” on the

protected site and Consistency Groups are forming at the set intervals.v Ensure that no volume status items are in the SRA-STAUS file on both the

protected and the recovery site for initial state. Or after you restore a remotemirror environment because of test failover, failover, or reprotect failure.

v Ensure that the Name Filter configuration is paired on both the protected andthe recovery site.

Notes:

v The SRA-STAUS file is in the SRA installation directory. For example, C:\ProgramFiles(x86)\VMware\VMware vCenter Site Recovery Manager\storage\sra\IBMDS8000\lib

v The content format of volume status’ item in the SRA-STAUS file:[SourceVolumeId:]TargetVolumeId@CopyType[@SessionId]:VOLUMESTATUS=VolumeStatus[@SessionId]

Example:

Symptom: Device ‘xxx’ cannot be matched to a remote peer device.

Figure 39. Unable to update array manager.

46 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 55: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Possible root cause and solution:v IP addresses are not correct. Check and correct IP addresses of DS8000 on both

sites.v The information that is recorded in the SRA-STAUS file is inconsistent with the

DS8000 remote copy status.v Name Filter configuration is not paired on the protected and the recovery site.

Check the Name Filter configuration on both sites. Correct the configuration inthe Array Manager and refresh the devices.

Remove incorrect device information in the SRA-STAUS file and restore the remotecopy relationship on DS8000.

Test failuresVerify the following items when you encounter a failure during test operations:v The user name and password for both the protected and the recovery site

DS8000 device’s HMC are the same.v Preconfigured/non-preconfigured is switched without rescanning SRA in SRM

on both the protected and the recovery site.v Make sure that you do not use TSE as the Global Mirror target volumes.

For environments that are not preconfigured, ensure that the following are checkedor corrected:v DS8000 user privilege problem, “administrator” required.v Not enough space in the extent pool.v No preconfigured flash copies to remote-copy target volumes on the recovery

site.

For environments that are preconfigured, ensure that the following are checked orcorrected:v Preconfigured FlashCopy were not created to remote-copy target volumes on the

recovery site.v More than one preconfigured FlashCopy was created.v The FlashCopy target volume is not mapped to the host.v The FlashCopy target volumes that are mapped to the host are shown as

Mounted in Hosts and Clusters/Configuration/Storage/Devices.

Figure 40. Device cannot be matched to a remote peer device warning

Chapter 6. Best Practices 47

Page 56: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Recovery failuresVerify the following items when you encounter problems during recoveryoperations.v The user name and password for both the protected and the recovery site

DS8000 device’s HMC are the same.v Preconfigured/non-preconfigured is switched without rescanning SRA in SRM

on both the protected and the recovery site.

For environments that are not preconfigured, ensure that the following items arechecked or corrected:v DS8000 user privilege problem, "administrator" required.v No preconfigured flash copies to remote-copy target volumes are on the

recovery site.v Make sure that you do not use TSE as the Global Mirror target volumes.v After disaster recovery, it is necessary to wait a few minutes and then refresh the

Devices in the SRM Array Managers on both sites. This step is necessary toensure that there is no error before reprotecting the plan.

For environments that are preconfigured, ensure that the following are checked orcorrected:v Preconfigured FlashCopy is not created to remote-copy target volumes on the

recovery site.v More than one preconfigured FlashCopy was created.v Make sure that you do not use TSE as Global Mirror target volumes.v Remote-copy target volume is not mapped to the recovery site.

“VMFS volume cannot be found” failuresVerify the following items when you encounter VMFS volume cannot be foundfailure during test or recovery operations.v For environments that are preconfigured, ensure that the pre-created backup

target volumes are pre-mapped to the ESX servers at the recovery site.v For environments that are not preconfigured, ensure that backup target volumes

are mapped to the ESX servers successfully at the recovery site.

Example:

Symptom: VMFS volume that is on recovered devices “xxx” and expected to beauto-mounted during HBA rescan cannot be found. Figure 41 on page 49 shows anexample error message of a VMFS volume that is on the recovered devices andexpected to be auto-mounted during HBA rescan, but cannot be found.

48 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 57: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Possible causes and solutions:v The backup target volumes are not mapped to the ESX servers.

– For environments that are preconfigured, check whether pre-created backuptarget volumes are pre-mapped to the ESX servers at the recovery site.

– For environments that are not preconfigured, check and correct hostconnections of the recovery site DS8000.

v Some extra time is required to be auto-mounted. Increase the value of parameterWaitExtraSeconds in Windows Registry HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\IBM Corporation\IBM System Storage DS8000 Adapter for VMwarevCenter Site Recovery Manager 5.x. This parameter makes DS8000 SRA waitextra time before it responds to SRM.

Note: You might also need to increase the storage.commandTimeout value ofVMware SRM appropriately.

Reprotect failuresVerify the following items when you encounter failure during reprotect operations:v The user name and password for both the protected and the recovery site

DS8000 device’s HMC are the same.v Preconfigured/non-preconfigured is switched without rescanning SRA in SRM

on both the protected and the recovery site.

For environments that are not preconfigured, ensure that the following are checkedor corrected:v For Global Mirror/Metro-Global Mirror, not enough space is in the extent pool

of the original remote-copy source volume to create Global Mirror FlashCopy.v For Global Mirror/Metro-Global Mirror, make sure that no session or Global

Mirror exists on the LSS of the original remote mirror target volume for theinitial state.

v For Metro-Global Mirror, make sure that no session or Global Mirror exists onthe LSS of the original Metro Mirror source volume for the initial state.

Figure 41. Incomplete Recovery

Chapter 6. Best Practices 49

Page 58: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

For environments that are preconfigured, ensure that the following are checked orcorrected:v For Global Mirror/Metro-Global Mirror, make sure that no session or Global

Mirror exists on the LSS of the remote mirror target volume for the initial state.v For Metro-Global Mirror, make sure that no session or Global Mirror exists on

the LSS of the original Metro Mirror source volume for the initial state.

Managing SRM proceduresVerify the following items when you encounter failure during SRM procedures.1. Refresh the devices in the SRM array managers. If there are no errors, go to

step 3.2. Check all the previously related SRA-STATUS volume status’ items in the SRA

installation directory. For example, C:\Program Files (x86)\VMware\VMwarevCenter Site Recovery Manager\storage\sra\IBM DS8000\lib

Note: The following example output shows the content format of the volumestatus item in the SRA-STAUS file:

3. Refresh the devices in the SRM array managers to ensure that there are noerrors.

Collect log filesIf the problem cannot be resolved by following any of the best practices or thetroubleshooting tips, collect the SRM log files and contact IBM support.

See “Getting information, help, and service” on page viii.

[SourceVolumeId:]Target VolumeId@CopyType[@SessionId]:VOLUMESTATUS=VolumeStatus[@SessionId]

50 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 59: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Notices

These legal notices pertain to IBM Storage Host Software Solutions productdocumentation.

This information was developed for products and services offered in the U.S.A.

IBM may not offer the products, services, or features discussed in this document inother countries. Consult your local IBM representative for information on theproducts and services currently available in your area. Any reference to an IBMproduct, program, or service is not intended to state or imply that only that IBMproduct, program, or service may be used. Any functionally equivalent product,program, or service that does not infringe any IBM intellectual property right maybe used instead. However, it is the user's responsibility to evaluate and verify theoperation of any non-IBM product, program, or service.

IBM may have patents or pending patent applications covering subject matterdescribed in this document. The furnishing of this document does not grant youany license to these patents. You can send license inquiries, in writing, to:

IBM Director of LicensingIBM CorporationNorth Castle DriveArmonk, NY 10504-1785U.S.A.

For license inquiries regarding double-byte character set (DBCS) information,contact the IBM Intellectual Property Department in your country or sendinquiries, in writing, to:

Intellectual Property LicensingLegal and Intellectual Property LawIBM Japan Ltd.1623-14, Shimotsuruma, Yamato-shiKanagawa 242-8502 Japan

The following paragraph does not apply to the United Kingdom or any othercountry where such provisions are inconsistent with local law:INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THISPUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHEREXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIEDWARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESSFOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express orimplied warranties in certain transactions, therefore, this statement may not applyto you.

This information could include technical inaccuracies or typographical errors.Changes are periodically made to the information herein; these changes will beincorporated in new editions of the publication. IBM may make improvementsand/or changes in the product(s) and/or the program(s) described in thispublication at any time without notice.

© Copyright IBM Corp. 2010, 2013 51

Page 60: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Any references in this information to non-IBM Web sites are provided forconvenience only and do not in any manner serve as an endorsement of those Websites. The materials at those Web sites are not part of the materials for this IBMproduct and use of those Web sites is at your own risk.

IBM may use or distribute any of the information you supply in any way itbelieves appropriate without incurring any obligation to you.

Licensees of this program who wish to have information about it for the purposeof enabling: (i) the exchange of information between independently createdprograms and other programs (including this one) and (ii) the mutual use of theinformation which has been exchanged, should contact:

IBM CorporationAttn: Office of Legal Counsel650 Harry RoadSan Jose, CA 95120-6099U.S.A.

Such information may be available, subject to appropriate terms and conditions,including in some cases, payment of a fee.

The licensed program described in this document and all licensed materialavailable for it are provided by IBM under terms of the IBM Customer Agreement,IBM International Program License Agreement or any equivalent agreementbetween us.

Any performance data contained herein was determined in a controlledenvironment. Therefore, the results obtained in other operating environments mayvary significantly. Some measurements may have been made on development-levelsystems and there is no guarantee that these measurements will be the same ongenerally available systems. Furthermore, some measurements may have beenestimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment.

Information concerning non-IBM products was obtained from the suppliers ofthose products, their published announcements or other publicly available sources.IBM has not tested those products and cannot confirm the accuracy ofperformance, compatibility or any other claims related to non-IBM products.Questions on the capabilities of non-IBM products should be addressed to thesuppliers of those products.

All statements regarding IBM's future direction or intent are subject to change orwithdrawal without notice, and represent goals and objectives only.

This information contains examples of data and reports used in daily businessoperations. To illustrate them as completely as possible, the examples include thenames of individuals, companies, brands, and products. All of these names arefictitious and any similarity to the names and addresses used by an actual businessenterprise is entirely coincidental.

TrademarksThis section describes trademark information.

52 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 61: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of theInternational Business Machines Corp., registered in many jurisdictions worldwide.Other product and service names might be trademarks of IBM or other companies.A current list of IBM trademarks is available on the Copyright and trademarkinformation website at:

http://www.ibm.com/legal/us/en/copytrade.shtml

VMware, the VMware logo, ESX, ESXi, vSphere, vCenter, and vCenter SiteRecovery Manager are trademarks or registered trademarks of VMwareCorporation in the United States, other countries, or both.

Microsoft, Windows Server, Windows, and the Windows logo are trademarks orregistered trademarks of Microsoft Corporation in the United States, othercountries, or both.

Other product and service names might be trademarks of IBM or other companies.

Notices 53

Page 62: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

54 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 63: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

Index

Aarray manager to VMware SRM

adding 36

Bbest practices

datastores and consistency groups 45troubleshooting

collect log files 50DiscoverArrays failure 45DiscoverDevices failure 46recovery failure 48reprotect failure 49SRM procedures 50test failure 47VMFS volume cannot be

found 48

Ccollect log files 50commands for

intermediate DS8000 22subordinate DS8000 25

configurationDS8000 Remote Copy for SRA 16non-preconfigured environments 18non-preconfigured environments for

Master Subordinate DS8000 28non-preconfigured environments for

Metro Mirror and Global Mirror 21non-preconfigured environments for

Metro-Global Mirror 23preconfigured environment 16preconfigured environments for

Master Subordinate DS8000 26preconfigured environments for Metro

Mirror and Global Mirror 20setting user privileges

non-preconfiguredenvironment 33

preconfigured environment 33SRA

for Master SubordinateDS8000s 25

for Metro Mirror and GlobalMirror 18

for Metro-Global Mirror 22Name Filter 41

Storage Replication Adapter 15

Ddatastores and consistency groups 45DiscoverArrays failure 45DiscoverDevices failure 46DS8000 Remote Copy for SRA

configuring 16

DS8000 softwareverify implementation 3

DS8000 SRA installation wizardrunning 7

DS8000 SRA softwareuninstalling 10

Hhelp

related publications vii

IIBM DS8000 SRA 29implementing SRA 1implementing VMware SRM 1installation

DS8000 SRA installation wizard 7DS8000 SRA software 10

MMetro Mirror 22Metro Mirror and Global Mirror 18mirroring configuration 3

Nnon-preconfigured environment

configuring 18for Master Subordinate DS8000

configuring 28for Metro Mirror and Global Mirror

configuring 21for Metro-Global Mirror

configuring 23performing test procedure 43

Pperforming

failover procedure 43reprotect procedure 44test procedure

non-preconfiguredenvironment 43

preconfigured environment 43preconfigured environment

configuring 16for Master Subordinate DS8000

configuring 26for Metro Mirror and Global Mirror

configuring 20test procedure 43

preparationDS8000 software

verify implementation 3

preparation (continued)mirroring configuration

verifying 3VMware vCenter SRM 4

Rrecovery failure 48reprotect failure 49

Ssetting user privileges

configuringnon-preconfigured

environment 33preconfigured environment 33

SRA Name Filter configuration 41SRA

for Master Subordinate DS8000s 25for Metro Mirror 22for Metro Mirror and Global

Mirror 18Name Filter configuration 41

SRM procedures 50system requirements 2

Ttarget volumes and Metro/Global Mirror

relationships 35test failure 47TPC-R coexistence 29troubleshooting

collect log files 50DiscoverArrays failure 45DiscoverDevices failure 46recovery failure 48reprotect failure 49SRM procedures 50test failure 47VMFS volume cannot be found 48

Uusage 35

adding array manager to VMwareSRM 36

creating target volumes andMetro/Global Mirrorrelationships 35

performingfailover procedure 43non-preconfigured

environment 43reprotect procedure 44test procedure 43

test procedurepreconfigured environment 43

© Copyright IBM Corp. 2010, 2013 55

Page 64: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

VVMFS volume cannot be found 48VMware SRM 29VMware vCenter SRM

installation 4

56 IBM System Storage DS8000 for VMware vCenter Site Recovery Manager 5.x User Guide

Page 65: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery
Page 66: IBM System Storage DS8000 for VMware vCenter Site …download4.boulder.ibm.com/sar/CMA/SDA/048ei/1/DS8000_Adapter_for... · IBM System Storage DS8000 forVMware vCenter Site Recovery

����