29
MUELLER TEMPLATE April 2016 Product Overview 2017 Harold Mosley, Product Brand Manager

Hydrant Flushing - cdn.ymaws.com

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

Product Overview 2017Harold Mosley, Product Brand Manager

Page 2: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Key Points

2

• Automated flushing improves water quality management efficiency.

• Consistency in flushing is a proven technique for effectively managing aging water

• Planned and consistent rotation of water in a distribution line increases disinfectant contact time.

• Improved contact time reduces THM and HAA5 levels

• Reduces biofilm build-up on distribution lines

Page 3: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Key Points

3

• Cost Effective…Conserve Time, Water and Money…Flush Less and Cut Expenses

• Models for All Climate Zones

• Portable to Permanent Installation Applications Available

• Flush to Atmosphere or Direct the Flush to a Discharge Point (i.e., pond, storm sewer, etc.)

• Flush distribution lines when demand is low and impact on customers’ water pressure will be minimal

Page 4: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Cost Containment

4

• Manual flushing of a water distribution line from a fire hydrant can be costly.

• A trouble point in a distribution system may require a crew to be onsite once a week (4 to 5 x month)

• Crew and vehicle time to service a trouble point can be as much as $120 / hour / vehicle

• The math... Hydrant vs. Hydro-Guard®• Hydrant

• Flushing 4 times per month [45 min./flush @ 1500 gpm}

• 270,000 gallons / month• $162 / month is cost of water flushed / $1,944 annually• Labor and vehicle costs of $5,400 (@ $50/hour)• Total: $7,344 per site

• Hydro-Guard® • Flushing 16 times per month [12 min./flush @ 150 gpm}

• 28,800 gallons / month• $17.28 / month is cost of water flushed / $207 annually

• Total Savings: $7,137 per site

Page 5: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® Hydrant Flushing / Portable Model

5

Page 6: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-6 Hydrant Flushing System

6

• Discharge: • Atmospheric discharge (to ground)

• Programming: • Built-In • Removable (Requires 545687 handheld)

• Height:• 25 inches above ground

Supports own weight – does not hang• Height adjustment of 4” either direction

• Piping Options:• Schedule 80 PVC (Basic Model)• Low Lead Brass (Standard HG-6)

• Backflow Prevention:• Air Gap

Page 7: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-6 Hydrant Flusher

7

Page 8: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

COMPETITIVE ANALYSIS

Competitor’s product: Kupferle 9700

8

Page 9: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® Cold Climate Models

9

Page 10: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-3 Longneck™

10

• Discharge: • Atmospheric discharge (to ground)

• Programming: • Removable (Requires 545687 handheld)

• Height:• Above Ground: 25 inches• Below Ground: 36” to 108”

• Piping Options:• Schedule 80 PVC • Low Lead Brass

• Backflow Prevention:• Air Gap

Page 11: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-3 Longneck™

11

1) Lockable HDPE composite lid2) Stainless diffuser screen with reduces energy of

discharging water and prevents pets from nesting inside of device; erosion controlling splash plate

3) Below ground protective sleeve (bury depth of 36” to 108”) with full circumference bottom plate, patented camlock release sytem and threaded connection for water service line

4) Adjustable 2” control valve, rated to 200 psi (burst pressure tested to 375 psi)

5) Patented camlock release system allow internals to be easily lifted out of protective ground sleeve and cantering stars allow it to be reinserted easily

6) Patented low pressure relief freeze protections allows water to drain from system when flushing stops

Page 12: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-3 Longneck™

12

Page 13: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-4 Longneck™

13

• Discharge: • Directed discharge (swale, storm pond or

storm sewer)

• Programming: • Removable (Requires 545687 handheld)

• Height:• Above Ground: 23 inches• Below Ground: 36” to 108”

• Piping Options:• Schedule 80 PVC• Low Lead Brass

• Backflow Prevention:• Air Gap

Page 14: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-4 Longneck™

14

1) Lockable HDPE composite lid2) Lockable protective ground sleeve (bury depth of

36” to 108”)3) OEM installed sampling and dechlorination system4) Cantering stars, insulation pad, full circumference

bottom plate, patented camlock release system and threaded connection for water service line

5) Patented camlock release system allow internals to be easily lifted out of protective ground sleeve and cantering stars allow it to be reinserted easily

6) Adjustable 2” control valve, rated to 200 psi (burst pressure tested to 375 psi) and patented low pressure relief freeze protections allows water to drain from system when flushing stops

Page 15: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-4 Longneck™

15

Page 16: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-8 Cold Climate

16

• Discharge: • Directed discharge (swale, storm pond or

storm sewer)

• Programming: • Removable (Requires 545687 handheld)

• Height:• Above Ground: Cast or Composite Lid• Below Ground: 48” to 108”

• Piping Options:• Low Lead Brass

• Backflow Prevention:• Double Check

Page 17: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-8 Longneck™

17

1) Cast or composite lid at grade, all other components below grade

2) Mueller Thema-Coil Meter Box is the platform this flushing device is built into, allows operator to raise the platform to surface for maintenance and lower for operation; includes lifting stap

3) OEM installed sampling and dechlorination system4) Freeze protected by 2” insulation pad and

mechanical thermal control valve5) Includes a double check backflow prevention

system and a 1” meter yoke that will accommodate a 1” meter or a 1” PRV (by others)

6) Adjustable 1” control valve

Page 18: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® HG-8 Cold Climate

18

Page 19: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® SMART Flushing Systems

19

Page 20: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® S.M.A.R.T. Flushing Systems

20

• Capable of Monitoring a Wide Range of Water Quality Conditions…

• Chlorine (Free or Total)• Temperature• pH• Turbidity• Flow• Pressure• Total Organic Compounds

• Automatically Initiates a Flush Event to Mitigate Poor Water Quality Conditions

• Allows for Two Way Communication • SCADA Compatible• Capable of Sending Event Notifications• Ideal for Remote Locations or Trouble

Points in a Distribution System

Communication:

Cellular

BlueTooth 2.4 GHz

Ehternet

Page 21: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® Water Quality Sampling Solutions

21

Page 22: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

WATER PRODUCTS

Hydro-Guard® Water Quality Sampling Solutions

22

• Retrieve Water Quality Samples from a Dedicated Sample Site

• Easy Access to Sampling Points in a Distribution Network

• Durable Construction

• Reliable Samples

Page 23: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

WATER PRODUCTS

Hydro-Guard® Water Quality Sampling Solutions

23

Page 24: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HYDRO-GUARD®

Hydro-Guard® Pressure Monitoring Systems

24

Page 25: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

SOLUTION… REMOTE PRESSURE MONITORING 24/7

Why monitor pressures throughout the distribution network?

• To prevent damage and interruption in service

• To reduce customer complaints

• To optimize pressure data

• To identify high pressure areas

• To reduce energy costs and improve pump operation efficiency

• To confirm auto flushers have operated properly and stay in compliance with Federal and State regulations for pressure and chlorine residuals

25

Page 26: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

WHAT ARE THE BENEFITS?

How can Mueller’s Intelligent Water Technology™ benefit your distribution network?

• Continuous verification of system pressure data anywhere in the distribution network

• Remote data logging and performance analytics

• Near-time condition alerts

• Powered by long-life Lithium battery

• User friendly web interface

• SCADA compatible with OPC Client protocol

26

Page 27: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

WHAT ARE THE BENEFITS?

How frequently can Mueller’s pressure monitoring system sample pressure?

• In a “steady state” mode the device will sample one reading every 15 seconds.

• In a “transient state” mode the device will sample 256 readings per second.

27

Stea

dy S

tate

Tran

sien

t Sta

te

Page 28: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

WHERE ARE MIWT PRESSURE MONITORS INSTALLED?

Install anywhere that pressure has been - or could be - an issue for your utility.

• District Metering Areas or Pressure Zones

• Pressure Regulating Valve Stations (PRVs)

• System Interconnects

• Pump Facilities

• Tanks

• Well Heads

28

Page 29: Hydrant Flushing - cdn.ymaws.com

MUELLER TEMPLATE

April 2016

HOW DOES IT WORK?

• Pressure readings are sampled from the pipeline or alternative installation points

• Sample data is transmitted from the pressure transducer to the control module

• Data is mapped, logged, analyzed and transmitted

29