Upload
annabel-griffin
View
217
Download
0
Tags:
Embed Size (px)
Citation preview
HQ Coil 23 and 25 Status
LARP Video MeetingSeptember 19, 2013
Dan Cheng
HQ Coil 23 Status
• HQ Coil 14 has been examined – Seemed to have similar epoxy fill issues between
polyimide trace layers as Coil 23 did– Coil was sectioned earlier– Traces were peeled back to examine epoxy fill of coil
• Coil 23 “Spot” has been cut away and examined– Does not affect the integrity of the coil in any way
• Instrumentation & QA on hold still, depending on decision on coil
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 2
Coil 23, Post-impregnation
Outer layer, RE Outer layer, straight section
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 3
Coil 23, Post-impregnation
Inner layer, RE Inner layer, LE
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 4
Outer Layer Comparisons
Coil 14 OL, Lead end Coil 23 OL, Lead end
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 5
Coil 14 Deconstruction
Coil 14 IL, RE, post-impreg. Coil 14 IL, RE, trace peeled off
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 6
Despite no fill between polyimide, coil shows complete fill
Kapton layer separated from trace
Coil 14 Deconstruction
Coil 14 OL, end of ramp area, post-impregnation, sectioned
Coil 14 OL, end of ramp area, trace peeled off
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 7
Coil 23 Inner Layer Check
Inner layer, Pole gapInner layer, pole gap,Spot cut away
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 8
Trace polyimide, with VHB backingKapton layer, conforming
to epoxy in pocket
Coil 23 Summary of Findings
Based on examination of Coils 14 & 23 Coil 23 IL, Return end
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 9
• White areas (shown, right) are likely surface conditions only – Is not an indicator of quality of fill
in the coil
• Coil fill is likely solid underneath the trace– Even where polyimide separated
from Kapton layer– Coil structures are likely fully
supported by epoxy composite
• If this coil passes electrical checks, this coil could be considered a usable coil
HQ Coil 25 Status
• Impregnation preparations will incorporate– Purchasing new CTD 101K epoxy kit (2-3 wk lead)– Revising our trace preparation procedures to improve
quality of fill between layers– Revising our lead splice procedures (based on input
from 8/22 QXF Coil WG meeting)• Impregnation preparations can start without
waiting for the changes mentioned above to be completed– But will have to be planned around HQ Coil 26 winding,
etc. operationsSept 19, 2013D. Cheng - HQ Coil 23, 25 Status 10
• Extra slides
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 11
Coil 14 Trace Preparations
Coil 14 IL trace laminate
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 12
Film of cleaner (alcohol or acetone?) between layers
CMM Data, At 26” (660mm) Location
Sept 19, 2013D. Cheng - HQ Coil 23, 25 Status 13
Coil 23 Coil 20, for reference
+250 µm~ 0.010”