40
Device Product Selection Guide 2014

HIMEL low voltage

  • Upload
    heru

  • View
    341

  • Download
    3

Embed Size (px)

DESCRIPTION

himel low voltage component

Citation preview

  • Device

    HIHPSG20130516

    Product Selection Guide 2014

  • Applicable. Available. Accountable.

    The Right Choice!

  • Applicable. Available. Accountable.

    The Right Choice!

  • 01-09Final Distribution

    Miniature Circuit Breaker & Switch Disconnectors

    Residual Current Device

    Control Devices

    Surge Protective Device

    Distribution Box

    Molded Case Circuit Breaker

    Air Circuit Breaker

    01-03

    04-06

    07

    08

    09

    10-11

    12

    10-12Low-voltage Distribution

  • Contactor

    Thermal Overload Relay

    Denite Purpose Contactor

    Relay

    Motor Protector

    Magnetic Starter

    Current Transformer

    Meter

    Digital Time Switch

    Voltage Stabilizer

    Control Signal

    Fuse

    Industrial Plug & Socket

    Terminal Block

    Cable Connector

    13

    14

    15

    16-17

    18

    19

    20

    21-22

    23

    24

    25-26

    27

    28

    29-30

    31

    13-19Motor Control & Protection

    20-24Power Energy Management

    25-31Industrial Control Components

  • 01

    Miniature Circuit Breaker & Switch Disconnectors

    18 mm Miniature Circuit Breaker

    In 1,3,6,10,16,20,25,32,40,50,63A

    Poles 1-4P

    Breaking Capacity 3/4.5/6kA

    Triping Curve B,C and D Curves

    Standard IEC 60898-1

    Certicate

    HDB6

    In 1,2,3,4,5,6,8,10,13,16,20,25,32,40,50,63A

    Poles 1-4P

    Breaking Capacity 4.5/6kA

    Triping Curve B,C and D Curves

    Standard IEC 60898-1

    Certicate

    HDB6s

    In 1,2,4,6,10,16,20,25,32,40,50,63A

    Poles 1-4P

    Breaking Capacity 6/10kA

    Triping Curve B,C and D Curves

    Standard IEC 60898-1

    Certicate

    HDB9

    Final D

    istribution

  • 02

    Miniature Circuit Breaker & Switch Disconnectors

    27mm Miniature Circuit Breaker

    Phase-neutral Circuit Breaker

    In 6,10,16,20,25,32A

    Poles 1P+N

    Breaking Capacity 4.5kA

    Triping Curve C Curves

    Standard IEC 60898-1

    Certicate

    HDB6p

    In 6,10,16,20,25,32A

    Poles 1P+N

    Breaking Capacity 3kA

    Triping Curve C Curves

    Standard IEC 60898-1

    Certicate

    HDB3

    In 63,80,100,125A

    Poles 1-4P

    Breaking Capacity 10kA

    Triping Curve C and D Curves

    Standard IEC 60947-2

    Certicate

    HDB2

    Final D

    istribution

  • 03

    Miniature Circuit Breaker & Switch Disconnectors

    Switch Disconnector

    In 20,32,63,100,125A

    Poles 1-4P

    Standard IEC 60898-1

    Certicate

    HDB6IS

    In 20,32,63,100A

    Poles 1-4P

    Standard IEC 60947-3

    HDB5

    In 32 63 100 125A

    Poles 1-4P

    Standard IEC 60947-3

    Certicate

    HDG9

    Final D

    istribution

  • 04

    Residual Current Devices

    Residual Current Operated Circuit Breaker

    In 6,10,16,20,25,32,40,50,60A

    Poles 1P+N,2P,3P,3P+N,4P

    Sensitivity 30,50,100,200,300mA

    Breaking Capacity 3kA

    Tripping Curve C,D Curve

    Standard IEC 61009-1

    HDB6LE

    In 63, 80, 100A

    Poles 1P+N,2P,3P,3P+N,4P

    Sensitivity 30,100,300mA

    Breaking Capacity 10kA

    Tripping Curve C,D Curve

    Standard IEC 60947-2

    HDB2LE

    In 6,10,16,20,25,32,40A

    Poles 1P+N

    Sensitivity 30mA

    Breaking Capacity 4.5kA

    Standard IEC 61009-1

    Tripping Curve C Curve

    Certicate

    HDB6pLE

    Final D

    istribution

  • 05

    Residual Current Devices

    Residual Current Operated Circuit Breaker

    In 6,10,16,20,25,32,40A

    Poles 1P+N

    Sensitivity 30mA

    Breaking Capacity 4.5kA

    Tripping Curve C Curve

    Standard IEC 61009-1

    HDB3LE

    In 6,10,16,20,25,32,40A

    Poles 1P+N

    Sensitivity 30mA

    Breaking Capacity 6kA

    Standard IEC 61009-1

    HDL6SP

    Final D

    istribution

  • 06

    Poles 1P+N,2P,3P,3P+N,4P

    Sensitivity 30,100,300mA

    Standard IEC 61009-1

    HDB6v

    Residual Current Protection Module

    Electromagnetic Type Residual Current Switch

    In 10,16,25,32,40,63,80,100A

    Type A/AC

    Poles 2P, 4P

    Sensitivity 30/100/300mA

    Standard IEC 61008-1

    Certicate

    HDB6VR

    Residual Current Devices

    Final D

    istribution

  • 07

    Control Devices

    Modular Contactor

    Poles 2P, 4P

    Rated Current 16, 20, 25, 32, 40, 63A

    Rated Insulation Voltage Ui 500V

    Rated Voltage Ue 230V

    Coil Voltage 220/230V

    Standard IEC 61095

    Time Range 0.1~10s, 10~120s, 30~480s

    Delay Type Delay after Power on/Power off

    Rated operational Voltage 230Vac

    Rated Current AC-15 5A

    Standard IEC 60947-5

    HDCH8P

    HDRT8

    Time Relay

    Final D

    istribution

  • 08

    Surge Protective Device

    Poles 1P, 1P+N,2P,3P,3P+N,4P

    Maximum Discharge Current 20,40,60,80,100

    Maximum continuous operational voltage Uc V 275,385,420,

    Standard IEC61643

    Certicate

    HDY1

    Surge Protective Device

    Final D

    istribution

  • 09

    Distribution Box

    Consumer Box

    NO.of loop Metal box & Plastic Cover 6,8,12,16,20,24Full Plastic 6,8,12,16,20,24,36

    Installation Surface/Flusion

    MaterialMetal box & Plastic Cover Full Plastic(re-retardancy)Full Plastic(Non-re-retardancy)

    Standard IEC60439-1 IEC 60670

    Certicate

    Dimension 250*200*140-1000*800*300

    Material Metal

    Standard EN60529

    Certicate

    HDPZ50

    HJXF

    Metal Enclosure

    Final D

    istribution

  • 10

    Molded Case Circuit Breaker

    Molded Case Circuit Breaker

    Frame Current 63A,100A,250A,400A,630A,800A

    Rated Insulation Voltage Ui AC 800V (Frame 63AF:AC 690V)

    Rated Impulse Withstand Voltage Uimp 8KV (Frame 63AF:6KV)

    Rated Operational Voltage Ue AC 415V (Frame 63AF:AC 400V)

    Poles 3P, 4P

    Rated Frequency 50/60Hz

    Standard IEC 60947-2

    Certicate

    Frame Current 63A,100A,225A,400A,630A,800A,1250A

    Rated Insulation Voltage Ui AC 800V (Frame 63AF:AC 690V)

    Rated Impulse Withstand Voltage Uimp 8KV (Frame 63AF:6KV)

    Rated Operational Voltage Ue AC 400V

    Poles 2P, 3P, 4P

    Rated Frequency 50/60Hz

    Standard IEC 60947-2

    Certicate

    HDM6s

    HDM1

    Low-voltage

    Distribution

  • 11

    Molded Case Circuit Breaker

    Earth-Leakage Circuit Breaker

    Frame Current 100A,250A,400A,630A

    Rated Insulation Voltage Ui AC 800V

    Rated Impulse Withstand Voltage Uimp 8KV

    Rated Operational Voltage Ue AC 400V

    Poles 3P, 4P

    Rated Frequency 50

    Standard IEC 60947-2

    Certicate

    Frame Current 100A,225A,400A

    Rated Insulation Voltage Ui AC 800V

    Rated Impulse Withstand Voltage Uimp 8KV

    Rated Operational Voltage Ue AC 400V

    Poles 3P, 4P

    Rated Frequency 50/60Hz

    Standard IEC 60947-2

    Certicate

    HDM6L

    HDM1L

    Low-voltage

    Distribution

  • 12

    Air Circuit Breaker

    Nominal Current 630A to 6300A

    Breaking Capacity (Ics) up to 100kA

    Rated Operational Voltage 400/415V, 690V ac (50/60Hz)

    Poles 3P, 4P

    Standard IEC/EN 60947-2

    Certicate

    Nominal Current 200A to 6300A

    Breaking Capacity (Ics) up to 100kA

    Rated Operational Voltage 400V ac (50/60Hz)

    Poles 3P, 4P

    Standard IEC/EN 60947-2

    Certicate

    HDW9

    HDW6

    Air Circuit Breaker

    Low-voltage

    Distribution

  • 13

    Nominal Current 9A to 95A

    Rated Power 4kW to 45kW

    Rated Control Circuit Voltage 24V to 400V, 50/60Hz

    Auxiliary Contact9~32A: 1NO or 1NC

    40~95A: 1NO+1NC

    Standard IEC/EN 60947-4

    Certicate

    Nominal Current 6A, 9A, 12A

    Rated Power 2.2kW, 3.2kW, 4.4kW

    Rated Control Circuit Voltage 24V to 400V, 50/60Hz

    Main Contacts 3NO, 4NO, 2NO+2NC

    Auxiliary Contacts 1NO, 1NC

    Standard IEC/EN 60947-4

    Certicate

    Nominal Current 9A to 630A

    Rated Power 4kW to 335kW

    Control Circuit Voltage 24V to 440Vac, 50/60Hz

    Auxiliary Contacts 9~95A: 1NO+1NC

    Matched Thermal Overload Relay HDR6

    Standard IEC/EN 60947-4

    Certicate

    Contactor

    Contactor

    HDC6

    HDC17K

    HJX2

    Motor C

    ontrol &

    Protection

  • 14

    Setting Current 0.1~0.15A, , 460~630A

    Tripping Class 10, 10A

    Auxiliary Contacts 1NO+1NC

    Matched Contactor HDC6

    Standard IEC/EN 60947-4

    Certicate

    Setting Current 0.1~0.15A, , 14~18A

    Tripping Class 10A

    Auxiliary Contacts 1NO+1NC

    Matched Contactor HDC17-K

    Standard IEC/EN 60947-4

    Setting Current 0.1~0.15A, , 80~93A

    Tripping Class 10, 10A

    Auxiliary Contacts 1NO+1NC

    Matched Contactor HJX2

    Installation Methods Plug-in / Independent

    Standard IEC/EN 60947-4

    Certicate

    Setting Current 0.1~0.16A, , 400~630A

    Tripping Class 10, 10A

    Auxiliary Contacts 1NO+1NC

    Installation Methods Independent

    Standard IEC/EN 60947-4

    Certicate

    Thermal Overload Relay

    Thermal Overload Relay

    HDR6

    HDR17-18

    HJRS1D

    HJRS2

    Motor C

    ontrol &

    Protection

  • 15

    Controlled Capacitor Rate Capacity 12kvar to 45kvar

    Rated Control Circuit Voltage 24V to 400V, 50/60Hz

    Standard IEC/EN 60947-4

    Switching Capacitor Contactor

    Definite Purpose Contactor

    HDC9

    Motor C

    ontrol &

    Protection

  • 16

    Main Contacts 4NO+1NC, 3NO+2NC

    Nominal Current 1.6A

    Rated Control Circuit Voltage 24V to 440V ac, 50/60Hz

    Standard IEC/EN 60947-4

    Certicate

    Rated Current 3A, 5A, 10A

    Coil Voltage AC6V-380V, DC6V-220V

    Poles 2P, 3P, 4P

    LED LED, No LED

    Certicate

    Working ModeA: Relay after power-on

    F: Relay after power-off

    Rated Working Voltage 120V 240V 400V

    Contactor Relay

    Miniature Relay

    Electronic Time Relay

    Relay

    HDZ6

    HDZ8P

    HJSZ3

    Motor C

    ontrol &

    Protection

  • 17

    Voltage 380V /400V

    Contactor Mode 1NO+1NC

    Contactor Endurance 5A Resistive

    Phase Failure & Phase Wrong Protect Time Reaction time 2S

    Standard IEC60947-5-1

    HXJ9

    Phase Failure and Sequence Protection Relay

    Impluse Relay

    Rated Voltage 250V

    Inrush Power 11VA

    Impulse Duration 50ms

    Maximum Switching Frequency 5 switching operations/minute

    Electrical Duralibity 50,000 cycles

    Operating Temperature - 5 + 40

    Standard IEC60947-4

    HDTL17

    Relay

    Motor C

    ontrol &

    Protection

  • 18

    Motor Protector

    Frame 32

    Setting Range 0.1-32A

    Rated Insulation Voltage Ui 690V

    Rated Impulse Withstand Voltage Uimp 6KV

    Rated Operational Voltage Ue 690V

    Rated Operational Frequency 50/60Hz

    Trip Class 10A

    Standard IEC 60947-1, IEC60947-2, IEC60947-4-1

    Certicate

    HDP6

    Motor Protector

    Motor C

    ontrol &

    Protection

  • 19

    Magnetic Starter

    Magnetic Starter

    Frame 13, 25, 95

    Setting Current 1-1.6A 80-93A

    Coil Voltage 36V, 110V, 127V, 220V, 230V, 380V, 400V

    Rated Operational Voltage 400, 690V

    Rated Insulation Voltage 690V

    Rated Operational Frequency 50/60Hz

    Standard IEC 60947-4

    HDS2

    Pow

    er Energy

    Managem

    ent

  • 20

    Primary Current 100-5000A

    Secondary Approval 5A,1A

    Maximum Voltage 0.66kV

    Class 0.5 , 1.0 , 3.0

    Short Time Thermal Current lth=100lh

    Rated Security Coefcient FS 5

    Standard IEC 60044-1

    HLMK

    Current Transformer

    Current Transformer

    Pow

    er Energy

    Managem

    ent

  • 21

    Type Single-phase

    Current Specication1.5(6)A, 3(6)A, 2.5(10)A, 5(20)A, 5(30)A, 10(40)A

    15(60)A, 20(80)A, 30(100)A

    Voltage 230V

    Power Loss Voltage circuit 2W per 10VA, Current circuit 4VA

    Normal Working Temp. - 10 + 45

    Limited Working Temp. - 25 + 55

    Standard IEC 62053-21

    Certicate

    HDDS607

    Single-phase Electronic Watt-hour Meter

    Three-phase Four-wire Electronic Watt-hour Meter

    Type Three-phase

    Current Specication1.5(6)A, 3(6)A, 2.5(10)A, 5(20)A, 10(40)A

    15(60)A, 20(80)A, 30(100)A

    Voltage 57.7/100V, 230/400V

    Power Loss Voltage circuit 2W per 10VA, Current circuit 4VA

    Normal Working Temp. - 10 + 45

    Limited Working Temp. - 25 + 55

    Standard IEC 62053-21

    HDTS607

    Meter

    Pow

    er Energy

    Managem

    ent

  • 22

    Type Single-phase

    Current Specication1.5(6)A, 3(6)A, 5(20)A, 10(40)A

    15(60)A, 20(80)A, 30(100)A

    Voltage 230V

    Power Loss Voltage circuit 2W per 10VA, Current circuit 4VA

    Normal Working Temp. - 10 + 45

    Limited Working Temp. - 25 + 55

    Standard IEC 62053-21

    Certicate

    HDSS607

    Three-phase Three-wire Electronic Watt-hour Meter

    Panel Meter

    Type Ammeter, Voltmeter, Frequency meter

    Specication 72*72mm

    Response Time 4s

    Impact Test Max acceleration 147m/s2

    Angular Deection 90

    Working Temp. - 25 + 40

    Standard IEC 60051

    Certicate

    Type Ammeter, Voltmeter, Frequency meter

    Specication 96*96mm

    Response Time 4s

    Impact Test Max acceleration 147m/s2

    Angular Deection 90

    Working Temp. - 25 + 40

    Standard IEC 60051

    Certicate

    H72 Series

    H96 Series

    Meter

    Pow

    er Energy

    Managem

    ent

  • 23

    Rated Control Voltage 230V AC

    Output LoopsB (Non-transparent cover)16-ON-16-OFF

    A (Transparent cover) 8-ON-8-OFF

    Contactor Endurance 250V/5A(Resistive)

    Rated Control Voltage 230V AC

    Output Loops 16-ON-16-OFF

    Contactor Endurance 250V/20A(Resistive)

    Rated Control Voltage AC:230 AC:400V

    Output Loops10-ON-10-OFFSingal output)

    8-ON-8-OFFDouble output

    Contactor Endurance 250V/25A(Resistive)

    Digital Time Switch

    HKG316T

    HKG316TD

    HKG816

    Digital Time Switch

    Pow

    er Energy

    Managem

    ent

  • 24

    Power Rating 10kVA-800kVA

    Input voltage range 304V~456V

    Voltage Regulator Accuracy 4%

    Power Rating 1.5kVA-45kVA

    Shape Desktop/Cabinet

    Input voltage range 280V~415V

    Voltage Regulator Accuracy 4%

    Output Voltage 220V/230V

    Power Rating 0.5kVA-30kVA

    Connection Europe plug British plug terminal connection

    Shape Desktop/Cabinet

    Voltage Regulator Accuracy 4%

    Standard EN61000-6-2 EN61000-6-4 EN61558-1

    Voltage Stabilizer

    HTND

    HSJW

    HSBW

    Single-phase Full Automatic AC Voltage Stabilizer

    Three-phase Full Automatc AC Voltage Stabilizer

    Three-phase Compensation AC Voltage Stabilizer

    Pow

    er Energy

    Managem

    ent

  • 25

    IP Degree IP65

    AC Ue 220 230 380V

    AC/DC Ue 6 12 24 36 48 110 220V

    Color White/Green/Red/Yellow/Blue

    IP Degree IP55

    SpecicationAC-15: 380V/2A 220V/3.3A

    DC-13: 220V/0.5 110V/1.1A

    Endurance Type Mechanical type, Electric Type

    Light Type LED,Neon,Filament

    Button Type

    Momentary,Selective buttom with short handle,Selective buttom with long handle,Key-operated selective switches,Mushroom,Emergency,Two-head,Flush,Indication lamp

    Color White/Green/Red/Yellow/Blue/Orange

    Control Signal

    HLD11

    HLAY5

    Indicator Light

    Pushbutton Switches

    Industrial Control

    Com

    ponents

  • 26

    IP Degree IP55

    SpecicationAC-15:660V/1.1A,380V/2.0A/220V/3.3A

    DC-13:440V/0.25,220V/0.5A,110V/1A

    Endurance Type Mechanical type, Electric Type

    Button Type

    Momentary (illuminated,unilluminated)Maintained (illuminated,unilluminated)Full protection,Selective (Illuminated)Key-operated,Mushroom,Emergency,

    Color White/Green/Red/Yellow/Blue

    IP Degree IP55

    Endurance Type Mechanical type, Electric Type

    Light Type LED,Neon,Filament

    Button Type

    Momentary (illuminated,unilluminated)Maintained (illuminated,unilluminated)Waterproof (illuminated,unilluminated)Selective buttom with short handle,Selective buttom with long handle,Key-operated,

    Color White/Green/Red/Yellow/Blue

    Control Signal

    HLAY7

    HLAY8

    Pushbutton Switches

    Industrial Control

    Com

    ponents

  • 27

    Fuse Link Type 00,1,2,3

    In 2-160A

    Base Type 00,1,2,3

    In 160250400650

    Cylindrical Fuse Type 32,63

    In 2-32A

    Holder Type 32X,32,63X,63

    Pole 1-3P

    In 32,63

    Material

    Resin with IndicatorResin without IndicatorNylon with IndicatorNylon without Indicator

    Fuse

    HRT16

    HRT16 Base

    HRT18

    HRT18 Fuse Holder

    Fuse

    Industrial Control

    Com

    ponents

  • 28

    Fuse

    Connecting Type Fixed and Moving

    Pole 2P+E, 3P+E, 3P+N+E

    Voltage 110-415V

    Current 16A, 32A, 63A, 125A

    Standard IEC 60309-1-2

    HDPM,HDP,HDSM,HDSF

    Industrial Plug & Socket

    Multi-function Industrial Plug and Socket

    Connecting Type Multi-function

    Pole 2P+E

    Voltage 110V, 230V

    Current 16A

    Standard IEC 60309-1-2

    HDPS

    Industrial Plug & Socket

    Industrial Control

    Com

    ponents

  • 29

    Hole: 4, 6, 8, 10, 12, 14, 16

    Hole Diameter 5.2mm, 6mm

    Cross Section 6*9mm,8*12mm

    Screw Dimension M4*8mm, M5*10mm

    Max Current 100A,150A

    Hole: 4, 6, 8, 10, 12, 14, 16

    Hole Diameter 5.2mm, 6mm

    Cross Section 6*9mm,8*12mm

    Screw Dimension M4*8mm, M5*10mm

    Max Current 100A,150A

    Hole: 6, 8, 10, 12, 14, 16

    Hole Diameter 5.2mm, 6mm

    Cross Section 6*9mm,8*12mm

    Screw Dimension M4*8mm, M5*10mm

    Max Current 100A,150A

    Terminal Block

    HTB010

    HTB019

    HTB007

    Terminal Block

    Industrial Control

    Com

    ponents

  • 30

    Terminal Block

    Hole: 78, 109, 116, 133

    Hole Diameter 5 9mm

    Screw Dimension M4*8mmM6*12mm

    Max Current 100 200A

    Hole: 2*7, 2*15, 4*7, 4*11, 4*15

    Hole Diameter 5.2mm

    Screw Dimension M4

    Max Current 125A

    Terminal Block

    HTB043

    HTB112

    Terminal Block

    Industrial Control

    Com

    ponents

  • Thread External Diameter: 12, 16, 20, 25, 32, 40, 50, 63mm

    7, 9, 11, 13.5, 16, 21, 29, 36, 42, 48mm

    Working Temp.: - 40 + 100

    Max Temp. In Short Time: + 120

    Cable Connector

    HFF

    Cable Connector

    Industrial Control

    Com

    ponents

  • Cable Connector

  • A Company to Serve You Where You Are

    E-mail Address:[email protected]

    ve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve

    E-mail Address:[email protected]

  • A Company to Serve You Where You Are

    E-mail Address:[email protected]

    ve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve A Company to S You Where You Are

    E-mail Address:[email protected]

    erve

    E-mail Address:[email protected]

  • Device

    HIHPSG20130516

    Product Selection Guide 2014