17
Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245 Immersion Heaters 247 Temperature Controls & Protectors 248 Submersible Heaters/Controllers 249 In-Line Heaters 251 Heat Pumps 252 Heat Exchanger 253 Heat/Cool Pumps 255 Air-Cooled Water Chillers 256 In-Line Chillers 257 Air Cooled Coil Water Chillers 258 Air Cooled & Aquarium Chillers 259 Water Cooled Chillers 260 Chiller Barrel Packages HEATERS/CHILLERS

HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

244 SECTIONProducts / Products / Products

244

PRODUCTS245 Immersion Heaters247 Temperature Controls & Protectors248 Submersible Heaters/Controllers249 In-Line Heaters251 Heat Pumps252 Heat Exchanger253 Heat/Cool Pumps255 Air-Cooled Water Chillers256 In-Line Chillers257 Air Cooled Coil Water Chillers258 Air Cooled & Aquarium Chillers259 Water Cooled Chillers260 Chiller Barrel Packages

HEATERS/CHILLERS

Page 2: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

HEATERSPTC Immersion Heaters

245

PTC (POSITIVE TEMPERATURE COEFFICIENT) IMMERSION HEATERSSmartOne® Electric Immersion Heaters utilize Positive Temperature Coefficient (PTC) semiconductors as the heating element. They are “self-limiting” - the maximum temperature is internally limited regardless of the operating conditions thereby providing built-in safety. As the PTC elements heat up, their resistance to electrical current increases. In the aquaculture industry, a common threat to heater life is buildup in waters with dense solids resulting in overheat conditions. Since these conditions will not cause the SmartOne® to overheat, it will last significantly longer than a traditional heater (periodic cleaning is still recommended). The maximum output temperature is below the ignition point of most plastic tanks so overheat damage is prevented if the element is operated in air or becomes covered with buildup. The EASYPLUG™ PTC heaters offer simple, easy plug-in installation; simply mount the heater, plug it into the control, and plug the control into a wall receptacle. Stainless steel models for fresh water, titanium models for salt water. Controls sold separately. One-year warranty.

SmartOne® S1 SERIES, METAL OVER-THE-SIDE HEATERS* (CONTROLS SOLD SEPARATELY-SEE PG 247) SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH3000 230 1 18” 23” 11 S1H30 $368.99 S1H30T $446.29 4000 230 1 24” 29” 13 S1H40 467.29 S1H40T 570.19 5000 230 1 30” 35” 15 S1H50 556.49 S1H50T 677.29

SmartOne® S1L SERIES, METAL BOTTOM HEATERS* (CONTROLS SOLD SEPARATELY-SEE PG 247) HORIZONTAL VERTICAL SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH LENGTH LENGTH (LBS) MODEL EACH MODEL EACH3000 230 1 18” 23” 11 S1L30 $503.99 S1L30T $660.49 4000 230 1 24” 29” 13 S1L40 606.89 S1L40T 740.29 5000 230 1 30” 35” 15 S1L50 691.99 S1L50T 858.89

SmartOne® EasyPlug™ METAL OVER-THE-SIDE HEATERS* (EasyPlug™ CONTROLS SOLD SEPARATELY) SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 7” 11” 7 S1H10 $237.29 S1H10T $285.59 1000 230 1 7” 11” 7 S1H11 237.29 S1H11T 285.59 1700 115 1 12” 17” 10 S1H17 292.99 S1H17T 349.69 1700 230 1 12” 17” 10 S1H18 292.99 S1H18T 349.69 *Includes 8½’ flexible cord with plug. cULus Listed and CE Certified.

SmartOne® EasyPlug™ AXIAL FLEXIBLE CORD METAL BOTTOM HEATERS* (EasyPlug™ CONTROLS SOLD SEPARATELY) HORIZONTAL SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 6” 14” 6 S1A10 $408.49 S1A10T $505.09 1000 230 1 6” 14” 6 S1A11 388.99 S1A11T 505.09 1700 115 1 10” 18” 8 S1A17 460.99 S1A17T 564.89 1700 230 1 10” 18” 8 S1A18 460.99 S1A18T 537.99 *Includes 8½’ flexible cord with plug. cULus Listed and CE Certified.

SmartOne® EasyPlug™ 90° FLEXIBLE CORD METAL BOTTOM HEATERS* (EasyPlug™ CONTROLS SOLD SEPARATELY) HORIZONTAL SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 6” 12” 7 S1L10 $509.29 S1L10T $565.99 1000 230 1 6” 12” 7 S1L11 484.99 S1L11T 565.99 1700 115 1 14” 16” 10 S1L17 568.99 S1L17T 655.19 1700 230 1 14” 16” 10 S1L18 568.99 S1L18T 623.99 *Includes 8½’ flexible cord with plug. cULus Listed and CE Certified.

EasyPlug™ DIGITAL TEMPERATURE CONTROLS* MODEL VOLTS PHASE MAX AMPS TEMPERATURE RANGE SHIP WT (LBS) EACHDRAE15-1 115 1 15 -30° - 220°F (-34° - 104°C) 3 $236.29 DRAE15-2 230 1 8 -30° - 220°F (-34° - 104°C) 3 323.39 DRAE8L REPLACEMENT SENSOR 66.19 *Includes 8’ vinyl sleeved sensor and 5½’ flexible power cord with plug. For indoor use only. cULus Listed and CE Certified.

*Includes 3’ of wire and conduit. cULus Listed and CE Certified.

SMARTONE® PTC HEATERS

SMARTONE® EASYPLUG™ PTC HEATERS

*Includes 3’ of wire and conduit. cULus Listed and CE Certified.

HOT ZONE

LENGTH

HOT ZONE

LENGTH

HORIZONTAL LENGTH

HORIZONTAL LENGTH

HORIZONTAL LENGTHSmartOne® and EasyPlug™ are trademarks and/or registered trademarks of Tom Richards, Inc. DBA Process Technology.

Page 3: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

246 HEATERSResistance Immersion Heaters

RESISTANCE IMMERSION HEATERSThe EASYPLUG™ Resistance Immersion heaters offer simple, easy plug-in installation for aquaculture applications. To install, simply mount the heater, plug it into the control, and plug the control into a wall receptacle. Heaters come standard with the Protector 1 over-temperature control system which utilizes a heat sensitive thermal protector to detect overheat conditions. The thermal protector, placed inside a thermowell and positioned in contact with the heater sheath, will stop power to the heater in the event of low liquid level. Heaters and controls are UL-listed and CE-certified, and work with both 50/60Hz. The Heavy-Duty Resistance Immersion heaters can handle almost any immersion water heater need and are perfect for automatic “set it and leave it” applications. Choose type 316 stainless steel for freshwater applications and titanium for salt water. Titanium offers the utmost in salt water corrosion resistance. The bottom heaters locate the hot zone along the bottom of your tank. The over the side heaters are easily positioned on the side of the tank. Never allow the water level to drop below the hot zone dimension shown, as heater failure and/or fire could occur (also, keep the hot zone clean of scale buildup). Protector 1 is available on all models. Controls sold separately. One-year warranty.

EasyPlug™ OVER-THE-SIDE HEATERS* (EasyPlug™ CONTROLS SOLD SEPARATELY-SEE PG 247) MAX SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH AMPS HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 8.4 7” 11” 6 ESA10 $187.99 ETA10 $242.59 1000 230 1 4.2 7” 11” 6 ESA11 187.99 ETA11 242.59 1800 230 1 7.5 12” 17” 9 ESA19 209.99 ETA19 282.49 *Includes 8½’ flexible cord with plug and heater mounting clip. cULus Listed and CE Certified.

EASYPLUG™ RESISTANCE IMMERSION HEATERS

EasyPlug™ BOTTOM HEATERS* (EasyPlug™ CONTROLS SOLD SEPARATELY-SEE PG 247) MAX HORIZONTAL VERTICAL SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH AMPS LENGTH LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 8.4 11” 24” 8 ELSA10 $342.29 ELTA10 $471.49 1000 230 1 4.2 11” 24” 8 ELSA11 342.29 ELTA11 471.49 1800 230 1 7.5 16” 24” 11 ELSA19 364.39 ELTA19 500.89 *Includes 8½’ flexible cord with plug. cULus Listed and CE Certified.

SINGLE TUBE OVER THE SIDE HEATERS* - SA & TA SERIES (CONTROLS SOLD SEPARATELY-SEE PG 247) MAX SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH AMPS HOT ZONE LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 8.4 7” 11” 5 H10-AQ $151.19 H10T $205.79 1000 230 1 4.2 7” 11” 5 H11 151.19 H11T 205.79 1800 115 1 15.0 12” 17” 8 H18** 173.29 H18T** 245.69 1800 230 1 7.5 12” 17” 8 H19 173.29 H19T 245.69 2500 230 1 10.4 17” 23” 10 H25 191.09 H25T 292.99 3500 230 1 14.6 23” 29” 13 H35** 205.79 H35T** 340.19 5000 230 1 20.9 32” 39” 16 H50** 281.39 H50T** 438.89 6000 230 1 25.0 40” 47” 19 H60** 301.39 H60T** 468.29 *Includes 8½’ flexible cord. ** 3’ of wire and conduit provided. cULus Listed and CE Certified.

HEAVY-DUTY RESISTANCE IMMERSION HEATERS

SINGLE TUBE BOTTOM HEATERS* - LSA & LTA SERIES (CONTROLS SOLD SEPARATELY-SEE PG 247) MAX HORIZONTAL VERTICAL SHIP WT. 316L STAINLESS STEEL TITANIUMWATTS VOLTS PH AMPS LENGTH LENGTH (LBS) MODEL EACH MODEL EACH1000 115 1 8.4 11” 24” 7 LH10-AQ $305.59 LH10T $434.69 1000 230 1 4.2 11” 24” 7 LH11 305.59 LH11T 434.69 1800 115 1 15.0 16” 24” 10 LH18** 327.59 LH18T** 464.09 1800 230 1 7.5 16” 24” 10 LH19 327.59 LH19T 464.09 2500 230 1 10.4 21” 24” 12 LH25 339.19 LH25T 482.99 3500 230 1 14.6 27” 24” 15 LH35** 354.89 LH35T** 529.19 5000 230 1 20.9 36” 48” 18 LH50** 405.29 LH50T** 677.29 6000 230 1 25.0 44” 48” 21 LH60** 426.29 LH60T** 705.59 *Includes 8½’ flexible cord. ** 3’ of wire and conduit provided. cULus Listed and CE Certified.

HOT ZONE

LENGTH

HOT ZONE

LENGTH

HORIZONTAL LENGTH

VERTICALLENGTH

HORIZONTAL LENGTH

VERTICALLENGTH

Page 4: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

HEATERSTemperature Controls/Thermal Protectors

247

DIGITAL TEMPERATURE CONTROLSThe Digital Temperature Controls and Combination Controls provide an LCD temperature display that indicates both the set and actual temperatures of the water, providing an extremely reliable and accurate temperature control for aquaculture heating systems. They can be set to display °F or °C. All controls are manufactured with UL-listed components.The Digital Combination Control consists of gasketed plastic enclosure, thermostat, contactor and replaceable Protector 1 thermal protection. Models NA30DXA and NA50DXA include upgradeable Protector 2 resettable thermal protection.

EasyPlug™ LCD DIGITAL TEMPERATURE CONTROLS* MAX D W H SHIP WT. MODEL VOLTS PHASE AMPS TEMPERATURE RANGE ACCURACY (IN) (IN) (IN) (LBS) EACHDRAE15-1 115 1 15 -30° - 220°F (-34° - 104°C) ± 1.5°F 2.5 2.6 7.5 3 $236.29 DRAE15-2 230 1 8 -30° - 220°F (-34° - 104°C) ± 1.5°F 2.5 2.6 7.5 3 323.39 *Includes 8’ vinyl sleeved sensor and 5½’ flexible power cord with plug. For indoor use only. cULus Listed and CE Certified.

REPLACEMENT HEATER THERMAL PROTECTORS Protector 1 is standard on all heaters, including EasyPlug™. It consists of a temperature sensitive protector installed in the heater which will shut down electricity (usually from low water level) to the heater element. Once activated, the protector must be replaced to restore power to the heater, so keep a spare one on hand.Protector 2 is an upgraded safety option that includes an audible alarm and manual reset button. During periods of high heater temperature or low water levels, an alarm will sound and electricity to the heater will be disconnected. The manual reset button will deactivate the alarm and reconnect electricity to the heater. Repeated alarm conditions may eventually cause the protector to fail, which will disconnect power. Restoring power will require a replacement protector. Both the control and heater need to be ordered with Protector 2.

MODEL EACH PROTECTOR 1 REPLACEMENT PTP1-A REPLACEMENT ELEMENT FOR OVER-THE-SIDE HEATERS $43.09

PLI REPLACEMENT ELEMENT FOR BOTTOM HEATERS 53.59

PROTECTOR 2 (OPTIONAL UPGRADE) PTP2 RESETTABLE ELEMENT FOR OVER-THE-SIDE HEATERS $43.09

PLII RESETTABLE ELEMENT FOR BOTTOM HEATERS 53.59

PROTECTOR 1

PROTECTOR 2

ECONOMICAL LCD DIGITAL TEMPERATURE CONTROLS* MAX D W H SHIP WT. MODEL VOLTS PHASE AMPS TEMPERATURE RANGE ACCURACY (IN) (IN) (IN) (LBS) EACHNA15D 115 1 15 -30° - 220°F (-34° - 104°C) ± 1.5°F 2.5 2.6 7.5 3 $157.49 NA8D 230 1 8 -30° - 220°F (-34° - 104°C) ± 1.5°F 2.5 2.6 7.5 3 157.49 *Includes 8’ vinyl sleeved sensor. For indoor use only. cULus Listed.

LCD DIGITAL COMBINATION CONTROLS W/PROTECTOR 1 THERMAL PROTECTION* MAX D W H SHIP WT. MODEL VOLTS PHASE AMPS TEMPERATURE RANGE ACCURACY (IN) (IN) (IN) (LBS) EACHNA30D 115 1 30 -30° - 220°F (-34° - 104°C) ± 1.5°F 6 8.5 13.6 15 $549.19 NA30DX 230 1 OR 3 30 -30° - 220°F (-34° - 104°C) ± 1.5°F 6 8.5 13.6 15 614.29 NA50DX 230 1 OR 3 50 -30° - 220°F (-34° - 104°C) ± 1.5°F 6 8.5 13.6 16 645.79 *Includes 8’ vinyl sleeved sensor. For indoor use only. cULus Listed.

LCD DIGITAL COMBINATION CONTROLS W/PROTECTOR 2 THERMAL PROTECTION* MAX D W H SHIP WT. MODEL VOLTS PHASE AMPS TEMPERATURE RANGE ACCURACY (IN) (IN) (IN) (LBS) EACHNA30DXA 230 1 OR 3 30 -30° - 220°F (-34° - 104°C) ± 1.5°F 6 8.5 13.6 15 $706.69 NA50DXA 230 1 OR 3 50 -30° - 220°F (-34° - 104°C) ± 1.5°F 6 8.5 13.6 16 738.19 *Includes 8’ vinyl sleeved sensor. For indoor use only. cULus Listed.

MODEL EACHDRAE8L REPLACEMENT SENSOR FOR ALL THERMOSTATS AND COMBINATION CONTROLS $66.19

Temperature Controller

NA15D NA30DX NA50DX

Heate

rs

H10H10T X

H11H11T X X

H18H18T X

H19H19T X X

H25H25T X X

H35H35T X X

H50H50T X X

H60H60T X X

LH10LH10T X

LH11LH11T X X

LH18LH18T X

LH19LH19T X X

LH25LH25T X X

LH35LH35T X X

LH50LH50T X X

LH60LH60T X X

Page 5: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

248 HEATERSSubmersible Heaters/Controllers

T11102

MODEL WATTS LENGTH EACH 4+

T11702 25 8.9" $20.19 $19.18

T11102 50 7" 21.49 20.42

T11202 100 8.9" 22.89 21.75

T11602 150 12" 25.79 24.50

T11302 200 12" 26.79 25.45

T11402 300 15.5" 30.19 28.68

T11502 400 15.5" 32.09 30.49

Hydor® is a registered trademark of Hydor S.R.L. LLC.

Heating TipUse several small heaters in place of one large (expensive) heater. Plug them into two different circuits, in case one becomes overloaded. Always use GFCIs when electricity is used in or near water.

TC11

Sensor

EC230R

TEMPERATURE CONTROLLERSAqua Logic® digital temperature controllers can be used in a variety of applications where a device needs to be turned on/off based on temperature rise or fall. A three-button touch keypad selects °F or °C, set point temperature, differential and operating mode (heating or cooling). NEMA 4X, rated for outdoor use.Temperature range for the controller is from -30 to 220°F (-22 to 105°C). The differential adjustment range is 1 to 30°F. Power cord lengths are 40” (1 m) each. The temperature sensor probe is encased in titanium and has an 8’ cable.Single stage controllers operate one device, either a chiller (1/2 hp and smaller) or a heater (1,000 watts or smaller). Dual stage controllers can be connected to both a chiller (1/2 hp and smaller) and heater (500 watts and smaller).Dual stage controllers will only allow one device to be “on” at a time. Example: stage 1 heating set point at 74°F with 1°F differential will have the heater come on when the temperature drops to below 73°F, then turn off at 74°F. One-year warranty.

VOLTS/ SHIP WT MODEL AMP (LBS) EACH

TC11 CONTROLLER, SINGLE STAGE 115/10 2 $128.99TC12 CONTROLLER, DUAL STAGE 115/8 3 198.99EC115R CONTROLLER, SINGLE STAGE 115/20 4 208.99EC230R CONTROLLER, SINGLE STAGE 230/15 4 208.99TC11S REPL. SENSOR (FITS ALL) — 1 68.99Aqua Logic® is a registered trademark of Aqua Logic, Inc.

SUBMERSIBLE HEATERS These Hydor® Theo heaters are the safest submersible heaters we could find in the market today. They are completely submersible, UL-approved, salt water compatible and shatterproof. Instead of the typical metal element in a breakable glass tube, these heaters utilize a polymer sheet that uniformly heats a shatterproof glass tube. The temperature is controlled and maintained by a highly precise micro-switch controller, adjustable from 70 to 89ºF. Heaters are 115V/ 60 Hz with a 6’ cord. One-year warranty.

FW SW

Learn from our own industry experts Dr. Tom Losordo and Dennis DeLong.• An introduction to recirculating systems• Critical considerations before designing recirculating systems• Component options for use in recirculating production systems• Developing an appropriate design for your aquaculture application• Management principles of recirculating aquaculture systemsPentairAES.com/workshops

RAS TECHNOLOGY WORKSHOP

Page 6: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

HEATERSIn-line Heaters

249

1.5–4kW models

6–18kW models

How to Extend Heater Service LifeHeaters are, of course, hot! The very high heat on the skin of the heater causes dissolved minerals like calcium to precipitate out of solution. The precipitant attaches itself to those hot spots, insulating the heater casing from the cooling water. Heat that can’t get out builds up inside and, if it gets hot enough, heater failure will occur. Always make sure the heater has a rapid flow of water over its hot zone. Never let the water get too low or let a crust build up on the casing (this will void your warranty).Heater life can be greatly extended by removing insulating deposits as soon as possible. In hard water, inspect heaters for deposits once weekly initially and then as experience dictates. It doesn’t take very much to cause a serious problem.

Direct immersion heaters:To clean the heater, unplug the power and allow heater element to cool. Remove heater from the water and treat with a diluted bath of nitric acid (rust remover), citric acid or other lime and scale deposit remover. Be sure to wear eye protection and rubber gloves when working with acid. The heater should only require this bath for several minutes. When the scale deposits begin breaking up or dissolving, remove the heater from the acid and wipe down with a cloth. Rinse with

water. Place heater back into service. If an acid solution is not handy, use a steel wire brush to brush off the deposits. Be sure to clean the area where the small diameter tube rests behind the heater tube, as this area is especially vulnerable to deposit buildups. Care should be taken not to scratch, gouge or wear away the metal surface of the heater when using the brushing technique.

In line heaters:When installing an in line heater it is recommended that you plumb it so to have a bypass loop to isolate it making it easy to remove periodically for inspection without shutting down your system. Disconnect power to the heater, let it cool, and disconnect from system at the unions. Mix a diluted bath of nitric acid (rust remover), citric acid or other lime and scale deposit remover in a 5 gallon bucket. Be sure to wear eye protection and rubber gloves when working with acid. Via a small submersible water pump in the bucket circulate the solution thru the heater chamber for 10 - 15 minutes. Move pump to a bucket of clean water and circulate thru the heater to rinse. Disconnect heater from pump and do a visual inspection by shining a flash light down both ends of the heater chamber. If it appears that calcium deposits are on the coils, repeat above process. If the buildup on the heater coils is organic, such as slime, use the same process above but with a dilute bleach solution (1 part bleach, 3 parts water).

TECH TALK 55

IN-LINE HEATERSThe Aqua Logic® in-line heaters are easy to install and available in both stainless steel and titanium. Stainless steel models are excellent for a variety of applications such as koi ponds and freshwater recirculating systems. Titanium models are ideal for saltwater systems and hydroponic systems that have nutrients in the water that would cause failure in stainless steel heaters. Designed for indoor use or outdoors (if protected from the sun and direct weather), these robust, durable heaters pack a lot of kilowatts into a very compact package. CE approved.• Easy to set digital temperature controller °F or °C• Safety high limit switch to prevent overheating with manual reset • Reversible flow switch allowing water input from either direction

(1.5–4 kW models)• Floor or wall mount

316 Stainless Steel Models SHIP WT MODEL KW VOLTS PHASE AMPS L W H (LBS) EACH

SSIL1 1.5 115 1 13 23” 6” 8.5” 12 $649.99SSIL2 2 115 1 17.4 23” 6” 8.5” 12 649.99SSIL3 2 220 1 9 23” 6” 8.5” 12 649.99

Pure Titanium Models SHIP WT MODEL KW VOLTS PHASE AMPS L W H (LBS) EACH

TIL1 1.5 115 1 13 23” 6” 8.5” 12 $774.99TIL2 2 115 1 17.4 23” 6” 8.5” 12 774.99TIL3 2 220 1 9 23” 6” 8.5” 12 774.99TIL4 3 220 1 13.6 23” 6” 8.5” 12 874.99TIL5 4 220 1 18 23” 6” 8.5” 12 929.99TILO6 6 220 1 28 23.5” 8” 8.75” 13 1,360.00TILO7 6 220 3 16 23.5” 8” 8.75” 14 1,740.00TILO8 8 220 1 37 23.5” 8” 8.75” 13 1,395.00TILO9 8 220 3 21 23.5” 8” 8.75” 14 1,775.00TILO12 12 220 1 55 23.5” 8” 8.75” 13 1,580.00TILO13 12 220 3 32 23.5” 8” 8.75” 13 2,000.00TILO15 15 220 3 40 23.5” 8” 8.75” 13 2,035.00TILO18 18 220 3 48 23.5” 8” 8.75” 13 2,070.00

Note: All three phase models use a delta configuration. Larger models available.

Page 7: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

250 HEATERSIn-Line Heaters

SPECIFICATIONS

TEMPERATURE CONTROL PID MICROPROCESSOR BASED DIGITAL THERMOSTAT TEMPERATURE ACCURACY + / - 1° F, DEPENDING ON OPERATING CONDITIONS PRESSURE RATING 100 PSIG (OPERATING) EFFICIENCY > 99% WETTED SURFACES ALL TITANIUM STANDARD STANDARD SAFETY • GROUNDED CONSTRUCTION • EMO EMERGENCY STOP BUTTON • FLUID FEATURES: OVERTEMPERATURE DETECTION (J TYPE THERMOCOUPLE) • ELEMENT OVERTEMPERATURE DETECTION (BI-METALLIC SNAP SWITCHES) • CONTROL FUSING (PRIMARY AND SECONDARY) • FM APPROVED OVERTEMPERATURE LIMIT CONTROLLER • GROUND FAULT PROTECTION (GFP) HOUSING NEMA 1 RATED, POWDER COATED METAL ENCLOSURE STANDARD CERTIFICATIONS cUL

TYTAN ELECTRIC IN-LINE WATER HEATERSFeatures and Benefits:• Improved Process Results: Heated DI water improves cleaning effectiveness and reduces

rinse time in most processes.• Cost Saving Design: >99% element efficiency contributes to low cost of ownership (COO)

and excellent return on investment (ROI).• Outstanding Cleanliness: 100% titanium heating elements provide very clean performance

for precision cleaning applications.• Reliable, Rugged Construction: Simple, heavy walled element construction for trouble

free operation and long life. Baffled element chambers enhance heat transfer efficiency.• Outstanding Temperature Responsiveness and Stability: Excellent temperature accuracy

over a wide flow range can substantially improve process consistency.• Fast/Easy Maintenance: Long-life element for minimal process down time. Designed for

easy service.• Rapid Installation: Minimal facility requirements. Heater is factory tuned to your

specifications. Only power and plumbing connections required.• Compact Configuration: Space saving design minimizes footprint requirements.

Wall mounted up to 72,000W. Floor mounted from 96,000W through 144,000W.• Minimum Flow Rate is 1 gpm

IN/OUT SHIP WT 316 STAINLESS STEEL TITANIUM WATTS VOLTS PHASE TEMP LIMIT (MNPT) W D H (LBS) MODEL EACH MODEL EACH

12,000 240 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0122403S $10,229.00 TY0122403 $10,271.0012,000 480 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0124803S 10,229.00 TY0124803 10,271.0018,000 240 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0182403S 10,624.00 TY0182403 10,651.0018,000 480 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0184803S 10,624.00 TY0184803 10,651.0024,000 240 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0242403S 10,939.00 TY0242403 10,950.0024,000 480 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 300 TY0244803S 10,939.00 TY0244803 10,950.0036,000 240 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 338 TY0362403S 13,119.00 TY0362403 13,556.0036,000 480 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 338 TY0364803S 11,044.00 TY0364803 11,579.0048,000 240 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 338 TY0482403S 15,860.00 TY0482403 16,164.0048,000 480 3 194° F (90° C) 1” 28.5” 13.5” 36.0” 338 TY0484803S 11,370.00 TY0484803 11,888.0072,000 240 3 194° F (90° C) 1” 37.5” 13.5” 36.0” 350 TY0722403S 24,149.00 TY0722403 24,590.0072,000 480 3 194° F (90° C) 1” 37.5” 13.5” 36.0” 350 TY0724803S 19,095.00 TY0724803 14,776.00

Floor Mounted Models96,000 480 3 194° F (90° C) 2” 28.0” 17.0” 66.9” 570 TY0964803S 23,173.00 TY0964803 24,188.00120,000 480 3 194° F (90° C) 2” 28.0” 17.0” 66.9” 580 TY1204803S 24,158.00 TY1204803 25,657.00144,000 480 3 194° F (90° C) 2” 28.0” 17.0” 66.9” 590 TY1444803S 28,507.00 TY1444803 30,330.00

Wall mounted

Wall Mounted Models

Page 8: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

HEATERSHeat Pumps

251

NOMINAL IN/OUT FLOW (GPM) AIR OUTLET SHIP WT MODEL HP BTUH KW VOLTS PHASE AMPS (FPT) MIN-MAX (CFM) L W H (LBS.) EACH

DSHP-4 1/3 4,000 1.1 115 — 7.2 3/4" 10–20 260 221/2" 141/4" 14" 90 $1,829.00DSHP-5 1/2 6,000 1.75 115 — 9.5 11/2" 12–25 350 24" 151/2" 16" 135 2,329.00DSHP-6 1/2 6,000 1.75 230 1 4.8 11/2" 12–25 350 24" 151/2" 16" 135 2,329.00DSHP-7 3/4 9,000 2.7 115 — 13 11/2" 15–30 590 24" 21" 15" 170 2,549.00DSHP-8 3/4 9,000 2.7 230 1 7 11/2" 15–30 590 24" 21" 15" 170 2,549.00DSHP-9 1 12,000 3.4 230 1 7.2 11/2" 20–35 610 27" 24" 15" 180 3,039.00DSHP-10 11/2 21,000 6.1 230 1 10.5 11/2" 25–40 772 31" 26" 19" 225 4,729.00

Do not operate in heat mode below 55°F air temperature.Delta Star® is a registered trademark of Aqua Logic, Inc.

L

Air Flow

H

W

DSHP-4

AIR COOLED HEAT PUMPS FW SW

Aqua Logic® Delta Star® Air Cooled Heat Pumps automatically handle both heating and cooling duties in fresh and saltwater applications. Titanium heat exchangers mean you get the best in corrosion resistance. A properly sized and installed heat pump will provide stable, controlled water temperature. Heat pumps include a dual stage digital temperature controller in a NEMA 4X-rated waterproof enclosure and will maintain water temperatures from 40–85ºF (5–29ºC). Controller will keep the temperature within 1° of the set point in °F or °C. Heat pumps should be mounted indoors where air temperatures stay above 55° F. One-year warranty. Note: When in heating mode, place the unit in a drip pan that has a drain connection as condensation can form a water puddle around the unit.• Heat or Chill with one unit • Fresh or Saltwater use • Compact Design • Quiet Operation • Dual Stage Digital Controller • Ozone Friendly Refrigerant (134A)

Heater SizingIf you are bringing water into your facility that must be heated, you can use an electric heater for all or just a portion of your heating. For instance, you may use solar, waste heat or room heaters first and use thermostatically controlled electric heaters as the final temperature control.To determine the approximate size heater to order, choose ONE of the three categories … then follow the calculation.1. RecirculatingIn a nonflowing system, heat is only lost to the surrounding air. The temperature difference between the ambient air and the water is the biggest factor. Also, the open area of the tank, the amount of agitation and the heat loss through the tank walls should be considered. All external pipes, filters, pumps, etc. will further cool the water.For every 9°F (5°C) difference, there should be 4 W of heat per gallon (3.8 liters) of water. Elevated, uninsulated tanks with a large amount of surface agitation, could require as much as 12 W per gallon per 9°F. For small glass aquariums use 8 W per gallon per 9°F.2. Temperature Raising OnlyCool water is used to fill tanks, and the water needs to be warmed before the fish are added. Time and ambient temperature will be considerations. For every 1,000 gallons (3,800 liters), 1,200 W (1.2 kW) are needed to raise the temperature 10°F (6°C) in 24 hours (this assumes ambient temp is the same as the water).3. Flow-Through HeatingA flow-through system has cool water entering and warmed water leaving (this is very wasteful and expensive without heat exchangers). Determine the maximum gallons per minute that you expect and the greatest temperature difference.1,000 W (1 kW) will raise the temperature of 6 gallons of water (23 liters) 1°F (.55°C) per minute.Example: 6 gpm with a 10°F difference = 10 kW.

Quick Heater Sizing Guide for Non-Flow-Through Calculation It's difficult to simplify something that is complicated, but use this quick reference chart to estimate the size of an electric heater.A tank with 1,000 gallons is in a room that will stay around 60°F, and you want the water temperature to be 87°F. If 4 W per gallon are needed for every 9°F, then: DT = 27°, 27 ÷ 9 = 3, 3 x 4 W = 12 W per gallon, 12 W x 1,000 gallons = 12,000 W. Assumes one large, uninsulated, uncovered fish tank plus one peripheral (such as a sand filter) and a pump with no extreme water/air interface (such as splash aerator or degassing tower). Minimize heater size and power use by insulating and covering.Follow the chart to keep the water at desired temperature, but if a few degrees of temperature loss is tolerable during brief periods of cold weather, use that temperature on the chart.For more accurate sizing, contact our technical department at 877-347-4788.

TECH TALK 74

Tank Size Temperature Difference (°F) (gallons) 9° 13.5° 18° 22.5° 27° Watts 250 1,000 1,500 2,000 2,500 3,000 400 1,600 2,400 3,200 4,000 4,800 550 2,200 3,300 4,400 5,500 6,600 700 2,800 4,200 5,600 7,000 8,400 850 3,400 5,100 6,800 8.500 10,200 1,000 4,000 6,000 8,000 10,000 12,000

Round up when in between wattages.

Page 9: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

252 HEATERSHeat Exchanger

WATER TO WATER HEAT EXCHANGER PACKAGESAqua Logic® complete, water-to-water heat exchanger packages are engineered for hot and cold water loop systems. The compact design and quiet operation make these systems perfect for indoor applications. Each package includes titanium heat exchanger, Schedule 40 PVC plastic shell (CPVC shell is available for an additional cost when the hot water supply is greater than 120°F), 304 stainless steel frame and hardware, digital temperature controller, water solenoid valve, flow meter, in-line strainer and customized plumbing. This system only requires an 115V power source and a hot or cold water supply. Prices are FOB CA. One-year limited warranty.• Fresh or saltwater Use• Titanium Tube in a PVC Shell• Preassembled and Ready for Easy InstallationNote: These heat exchangers directly absorb or reject heat from the tank system water into another water source (hot or cold). BTU capacities in the chart are based on the specific water temperature and flow rates shown. If any of these parameters change, the BTU removal capacity will change, and the heat exchanger may not meet your systems requirements. Contact us so we can assist you in the proper sizing of the equipment for your specific application.

1.1 - 3.5KW models 7 - 17.5KW models 26.3 - 70.2KW models

NOMINAL PROCESS WATER PROCESS WATER FLOW COLD/HOT WATER COLD/HOT WATER FLOW SHIP WT. MODEL BTUH* KW IN/OUT (GPM) IN/OUT (GPM)* L W H (LBS) EACH

HX-3W 3000 0.9 3/4” FPT 15 1/2” FPT 0.6 / .3 21” 61/4” 19” 30 $748.99HX-4W 4000 1.1 3/4” FPT 20 1/2” FPT 0.8 / .4 23” 61/4” 19” 30 768.99HX-6W 6000 1.7 11/2” FPT 25 1/2” FPT 1.2 / .6 241/2” 63/4” 19” 35 898.99HX-9W 9000 2.6 11/2” FPT 30 1/2” FPT 1.8 / .9 31” 63/4” 19” 35 968.99HX-12W 12000 3.5 11/2” FPT 35 1/2” FPT 2.4 / 1.2 341/2” 63/4” 19” 40 1,149.00HX-24W 24000 7 2” SLIP 40 1/2” FPT 5 / 2.5 34” 14” 23” 138 2,149.00HX-36W 36000 10.5 2” SLIP 40 3/4” FPT 7 / 3.5 41” 14” 23” 154 2,749.00HX-48W 48000 14 2” SLIP 60 3/4” FPT 10 / 5 49” 14” 23” 160 2,919.00HX-60W 60000 17.5 2” SLIP 60 3/4” FPT 12 / 6 561/2” 14” 23” 207 3,239.00HX-90W 90000 26.3 3” SLIP 90 3/4” FPT 18 / 9 131/2” 25” 43” 215 6,179.00HX-120W 120000 35.1 3” SLIP 120 1” FPT 24 / 12 131/2” 25” 53” 225 7,449.00HX-180W 180000 52.7 3” SLIP 145 11/2” FPT 36 / 18 131/2” 25” 72” 232 9,519.00HX-240W 240000 70.2 3” SLIP 180 11/2” FPT 48 / 24 131/2” 25” 82” 250 12,239.00

*Flow rate (gpm) and (BTU) rating is based on 40˚f ewt @ 10˚f ∆ t (cold) or 180˚f ewt @20 ˚f ∆ t (hot) water supply.

Page 10: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

HEATERSHeat/Cool Pumps

253

COMPARING THE COST TO HEAT YOUR BODY OF WATER OR AQUACULTURE SYSTEM

HEATER/FUEL TYPE COST BTU/$1.00ELECTRIC $.1065/KWH 32,000 LP GAS $1.87/GAL 40,100OIL $2.22/GAL 47,200 NATURAL GAS $1.218/THERM 67,300XLHP HEAT PUMP $.1065/KWH 185,600

XLHP® HIGH PERFORMANCE HEAT/COOL PUMPSWith today’s record energy costs, there’s never been a better time to invest in a Pentair Aquatic Eco-Systems XLHP® High Performance Heat/Cool pump. Compared to gas, oil or electric heaters, XLHP® High Performance Heat/Cool Pumps use just a fraction of the energy to generate the same amount of heat. In fact, just 20¢ worth of electricity produces $1.00 worth of heat generated by other methods.

More standard features than any other in its class• Both models are capable of heating and/or cooling the water. Full heat/cool

functionality.• Provides an AutoSet Temperature Control feature as standard. It monitors

water temperature and turns the pump on and off as needed, overriding the time clock to maintain desired temperature for convenient, hands-free control.

• Features the legendary Emerson® Copeland Scroll® Compressor that’s more efficient, durable, reliable and quieter than any piston-driven compressor.

• EPA-recognized, environmentally safe, non-ozone depleting R-410A refrigerant.

• 100% titanium heat exchanger assures corrosion-free performance for extra long life and value.

• LCD control board displays an intuitive, menu-driven readout with easy to follow, full word messages—no codes to memorize.

• Self-diagnostic software continuously monitors system for peak performance.• Thermostatic Expansion Valve (TXV) controls refrigerant flow for optimum

efficiency and BTU output over a wider operating temperature range.• Automatic defrost feature senses refrigerant temperature and helps prevent

the XLHP® Heat Pump from freezing, allowing the unit to operate effectively at even lower temperatures than many competing products.

• ETL listing is your assurance of safer, dependable operation.• BTU and efficiency independently certified by the Air Conditioning, Heating,

and Refrigeration Institute (AHRI). The AHRI Certified mark is applied only to HVACR equipment and components that have been independently tested to certify that manufacturers’ performance claims are accurate.

• Maximum working water pressure is 50PSI.• Port Size: 2”, unions included with model 460900-AQ

BREAKER RATING BTU/H CAPACITY COP** RATING FLOW (GPM) SHIP WTMODEL VOLTAGE HZ PHASE (AMPS) HEATING COOLING HEATING COOLING MIN MAX (LBS) EACH

460900-AQ 230* 60 1 50 127,000 72,000 5.4 4.1 30 120*** 278 $4,925.00460901-AQ 230* 60 1 50 140,000 80,000 5.7 4.1 30 120*** 320 5,240.00

* 230V +/- 10%. Heat pumps can run from 207-253V. **Coefficient of Performance. ***If system flow rate exceeds 120 GPM, a bypass valve is required.

38.7"(983 mm)

4.5"(114 mm)

9.25"(235 mm)

11.25"(286 mm)

45.5"(1156 mm)

34.0"(864 mm)

32.0"(813 mm)

30.7"(780 mm)

COLD AIR OUTFan

WARM AIR IN

Water Inlet(Cold)

Water Outlet(Warm) Evaporator Coil

Typical Heating Cycle Heat Pump Dimensions

Page 11: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

254 HEATERSHeat/Cool Pumps

11/2–5 HP Models71/2 & 10 HP Models

NOMINAL AMPS FLOW (GPM) AIR OUTLET SHIP WT MODEL HP BTUH** KW VOLTS* PHASE RLA / LRA MIN-MAX (CFM)*** L W H (LBS) EACH

HP1 11/2 18,000 5.2 208-230 1 5.9 / 38.6 20 -40 1,550 38 26 62 406 $5,399.00HP2 2 24,000 7 208-230 1 8.7 / 57.8 20 -40 1,550 38 26 62 389 5,869.00HP3 3 36,000 10.5 208-230 1 17.6 / 79 20 -40 4,385 48 35 62 500 7,269.00HP33 3 36,000 10.5 208-230 3 7.8 / 75 20 -40 4,385 48 35 62 495 7,269.00HP4 4 48,000 14 208-230 1 18.6 / 93.4 30-60 2,500 48 35 71 518 8,249.00HP43 4 48,000 14 208-230 3 11.7 / 100.1 30-60 2,500 50 35 71 515 8,249.00HP5 5 60,000 17.5 208-230 1 25 / 148 30-60 3,700 50 35 71 553 9,439.00HP53 5 60,000 17.5 208-230 3 17.3 / 123 30-60 3,700 58 35 71 538 9,439.00HP7.5 71/2 90,000 26.3 208-230 3 29 / 164 60-120 6,530 50 43 68 667 13,459.00HP7 10 120,000 35 208-230 3 36 / 225 60-120 9,800 61 48 74 850 15,629.00HP15 15 175,000 52.7 208-230 3 60 / 164 120-180 9,750 112 54 75 1578 29,059.00HP20 20 240,000 74.3 208-230 3 83 / 267 120-180 9,750 112 54 89 1657 35,999.00

*460V options available. **ARI net cooling capacity. ***Amount of hot air discharged from unit when operating.

HEAT/COOL PUMPS FW SW

Titan Air Cooled Heat Pumps by Aqua Logic® are designed for a wide range of applications such as a public aquarium, aquaculture facility, government or university research institution or hydroponics operation. All units are suitable for outdoor installation (but should be protected from direct weather). Heat pumps up to 5hp have a special ”Spine Fin” condenser coil which has proven to have superior heat transfer performance and capacity over traditional radially finned heat exchangers. This style condenser also has a much greater resistance to corrosion in harsh environments such as moist salty air or chemically tainted rainwater.In the cooling mode, the heat pump works as a chiller, cooling water to the temperature you select. In the heating mode, the heat pump works with the liquid refrigerant (Freon) flow in reverse. Freon absorbs heat from the air as it moves thru the condenser. As it heats, the Freon becomes a gas, which is then compressed by the compressor. The heat carried by the Freon is then released into the titanium heat exchanger and transferred into the circulated water.These models feature titanium helix coils and powder-coated shrouds. 2” PVC slip, in and out fittings on 2–10 hp; 3” PVC slip on larger units. 230V models listed; 460V also available. Dual stage digital temperature controller is enclosed in a NEMA4X enclosure with easy 3 push button programming and will maintain water temperatures in the range from 40°-85°F (4 to 29°C); you must specify desired temperature operating range when ordering. Units will lose heating efficiently when air temperature is under 40°F (4°C). Note min/max flow requirements (water pump not included). The controller can display in either °F or °C and will maintain the water within 1 degree of the set point. Water pressure should not exceed 40 psi. Allow a 4-week build time. Ship from factory via motor freight. One-year limited warranty.

• Heat or Chill with one unit • Titanium Heat Exchanger • Fresh or Saltwater use • Dual Stage Temperature Controller

15 & 20 HP Models

Page 12: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

CHILLERSAir-Cooled Water Chillers

255

AIR-COOLED WATER CHILLERS FW SW

Aqua Logic® Multi Temp Air-Cooled Water Chillers are used in aquaculture, public aquariums, live seafood holding and hydroponics systems. These large chillers have an insulated heat exchanger with titanium helix coils and commercial duty condensing units mounted on a stainless steel frame with bolt down leg tabs. Suitable for outdoor installations, but should be protected from direct weather. Digital temperature controller is in a splash-proof NEMA box with easy push-button programming. Controller displays in either ºF or ºC. Chillers operate between 40–80ºF (4.5–27ºC). Chillers 2–10 HP have a 2” slip inlet/outlet (15 HP and larger models have 3” inlet/outlet) and installed water flow switch to shut them down should flow to the heat exchanger stop. Water pressure should not exceed 40 psi. Ship motor freight from factory; allow a 4-week build time. Split models available (add “-SPLIT” to part number). One-year limited warranty.• Fresh or Saltwater Use • Insulated, Titanium Heat Exchanger • Digital Temperature Controller• Automatic Temperature Ranging • Water Flow Safety Switch 2–5 HP Models 71/2 & 10 HP Models

NOMINAL AMPS FLOW GPM AIR OUTLET SHIP WT MODEL HP* BTUH** KW VOLTS PHASE RLA/LRA MIN-MAX (CFM)*** L W H (LBS) EACH

MT-1 2 24,000 7 208 - 230 1 9 / 58 20-40 1,550 44 33 62 370 $5,309.00MT-3 3 36,000 10.5 208 - 230 1 14 / 72 20-40 2,175 44 33 66 396 6,319.00MT-4 3 36,000 10.5 208 - 230 3 12 / 77 20-40 2,175 44 33 66 386 6,319.00MT-5 4 48,000 14 208 - 230 1 21 / 109 30-60 2,500 51 38 62 474 7,479.00MT-6 4 48,000 14 208 - 230 3 15 / 91 30-60 2,500 51 38 62 474 7,479.00MT-7 5 60,000 17.5 208 - 230 1 27 / 158 30-60 3,700 56 38 70 520 8,389.00MT-8 5 60,000 17.5 208 - 230 3 19 / 137 30-60 3,700 56 38 70 528 8,389.00MT-9 7.5 90,000 26 208 - 230 3 28 / 164 60-120 6,530 48 42 68 670 12,099.00MT-10 10 120,000 35 208 - 230 3 35 / 225 60-120 9,800 58 46 68 815 14,049.00MT-15 15 180,000 52.7 208 - 230 3 55 / 164 120-180 9,750 112 56 75 1,559 25,369.00MT-20 20 254,000 74.3 208 - 230 3 83 / 267 120-180 9,750 112 56 89 1,714 31,419.00

*Larger sizes and 460 voltage options available. **ARI net cooling capacity. ***Amount of hot air discharged from unit when operating.

Heating Garden PondsKoi, goldfish, catfish, minnows, bluegills and many other fish are capable of living in ice-covered ponds in their natural conditions. But when you put a lot of fish in a small pond, a fishkill will result if the ice cover persists too long. To prevent a fishkill, all you need to do is keep a very small percentage of the surface ice-free for gas transfer. Use one or more small heaters with thermostats built for the purpose.Water temperatures below 65°F (18°C) can stress fish, reducing their resistance to disease. Rapid and extreme fluctuations can also cause disease. If your fish are extremely important to you, and you want to keep the temperature above 65°F, you will need to both insulate and heat your pond in most locations in the US. Unless you don’t mind spending a king’s ransom for heating, you will need to insulate and turn off all fountains, waterfalls and other water-chilling devices. Insulation can take the form of floating Styrofoam sheets, swimming pool cover, greenhouse structure, plastic sheeting, etc. Keep in mind that when water evaporates it has a significant cooling effect. This effect can account for as much as 80% of the total heat loss from open ponds. Be prepared to open the insulation on warm days; otherwise, excessive heating of the water can take place, shocking the fish.

It may be more cost-effective to transfer fish to indoor tanks with recirculating filter systems for the winter. This also allows for winter pond draining and maintenance. The heat loss in BTU/hr per square foot of pond surface is approximately 15 times the temperature difference between the desired water temperature and the coldest average air temperature. Example: If you wanted to maintain water temperature at 65°F, and you knew that the air temperature was going to drop to 35°F (24-hour average), you would have a 30° temperature difference x the surface area (which, in this case, we will say is 100 sq.ft. x 15) = 45,000 BTU/hr. If you insulate 80%, your heat loss will be less 80%.What are the heating equipment options? Immersion heaters that are outdoor-rated or submersible may be used, as well as the electric flow-through type. Gas heaters of the type used on hot tubs and swimming pools typically are more cost-effective for the large heating loads. Beware of copper or cuper nickel piping, which makes them incompatible with most fish cultures. They can be used, however, with stainless steel or titanium heat exchangers. The water should be filtered prior to entering the heater to avoid biofouling.

TECH TALK 123

Page 13: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

256 CHILLERSIn-Line Chillers

Delta Star® is a registered trademark of Aqua Logic, Inc.

IN-LINE AIR-COOLED WATER CHILLERS Aqua Logic® Delta Star® in-line, air cooled, water chillers are built with helical titanium evaporator coils for maximum cooling efficiency. Titanium is safe for all aquatic animals in fresh or salt water systems. The low profile design allows for easy placement in tight places and the quiet, internal, spring-mounted hermetic motor/compressor provides years of reliable service.All chillers come standard with a black ABS cover and digital electronic controller mounted on a 4’ cable, remote from the chiller unit. It displays the current temperature, set point temperature, and has a 1° differential, in either Fahrenheit or Celsius. A direct immersion titanium sensor probe with a 6’ cable is included with the controller. Delta Star® chillers are intended for use indoors or, if located outdoors, they must be installed in an enclosure protected from the direct weather in ambient air temperatures between 55°–90°F. If exposed to air temperatures outside of this range then optional ambient air control packages must be factory installed during the manufacturing of the chiller. All chillers require unrestricted air flow thru the condenser and thus must be located in a well-ventilated area. Maximum water pressure for all chillers is 20 psi. Units listed are compatible with 60 Hz current only. AE3 thru AE7 are charged with 134A CFC refrigerant, and AE8 is charged with R-417 refrigerant. Allow 2 weeks for delivery. Prices are FOB CA.

Standard Models For applications where the temperature to be maintained is in the range of 65°–80°F (18°–27°C) such as reef tanks and warm water fish exhibits.

Option A Models Cool water units designed for a temperature range of 50°–65°F (10°–18°C) for bait fish and temperate fish species.

Option B Models For those applications where the unit will need to maintain a very cold temperature in the range of 40°–80°F (4.5°–27°C) such as lobster tanks, cold water fish exhibits or research applications.

Important Temperature Range Information Water chillers are built for different water temperatures in order to work efficiently and to provide the full rated BTU output.Please specify operating temperature at time of order.Options available - bare sensors on controller, dry probe wells for inline sensors, outdoor enclosures, low ambient air controls, high ambient air controls, water flow switches and split systems with indoor heat exchanger and outdoor condensing unit, contact us for more information.

60 HZ NOMINAL AIR OUTPUT FLOW (GPM) SHIP WT STANDARD MODELS OPTION A MODELS OPTION B MODELSHP VOLTS BTUH AMPS (CFM) MIN-MAX L W H (LBS) MODEL EACH MODEL EACH MODEL EACH

1/4 115 3,000 5.4 240 8-15 183/4” 12” 11” 53 AE3 $918.99 AE3A $1,079.00 AE3B $1,219.001/3 115 4,000 7.2 260 10-20 221/2” 13” 11” 62 AE4 978.99 AE4A 1,149.00 AE4B 1,279.001/2 115 6,000 9.5 350 12-25 233/4” 151/4” 13” 110 AE5 1,489.00 AE5A 1,689.00 AE5B 1,819.001/2 230 6,000 4.8 350 12-25 233/4” 151/4” 13” 112 AE52 1,489.00 AE52A 1,689.00 AE52B 1,819.003/4 115 9,000 13 590 15-30 24” 201/4” 151/4” 145 — — — — AE6B 2,169.003/4 230 9,000 7 590 15-30 24” 201/4” 151/4” 145 — — — — AE62B 2,169.001 230 12,000 7.2 610 20-35 253/4” 233/4” 151/4” 150 — — — — AE7B 2,529.0011/2 230 21,000 10.5 772 25-40 261/4” 26” 171/2” 190 — — — — AE8B 3,869.00

2-YEAR WARRANTY

AE4

AE5 w/o Cover

FW SW

Page 14: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

CHILLERSAir-Cooled Coil Water Chillers

257

60 HZ NOMINAL AIR OUTPUT WATER FLOW IN/OUT SHIP WT STANDARD MODELS OPTION A MODELSHP VOLTS BTUH AMPS WATTS (CFM) RATE (GPM) L W H FIPT (LBS) MODEL EACH MODEL EACH

1/4 115 3,000 5.4 621 240 8–15 14” 12” 11” 3/4” 53 AE3D $998.99 AE3DA $1,259.001/3 115 4,000 7.2 828 260 10–20 181/2” 13” 11” 3/4” 62 AE4D 1,059.00 AE4DA 1,329.001/2 115 6,000 9.5 1092 350 12–25 181/2” 151/2” 13” 11/2” 110 AE5D 1,609.00 AE5DA 1,919.001/2 230 6,000 4.8 1104 350 12–25 181/2” 151/2” 13” 11/2” 112 AE5D2 1,609.00 AE5D2A 1,919.00

AIR-COOLED COIL WATER CHILLERS FW SW

Aqua Logic® Cyclone® Coil Water Chillers are perfect for hydroponics, fisheries research, education systems, living exhibits, animal hydrotherapy, lobster and seafood holding tanks, emergencies, and use in high organics. Place this chiller near the tank, drop the titanium coil in the water and turn it on. Water circulation past the coil is required. Titanium is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems. If there is no circulation, place an air diffuser under or attach to the coil. The high efficiency of this chiller is due to its unique helical coil design. ½ HP units come with 6’ flexible stainless steel lines. Units under ½ HP have 5’ flexible lines feeding the 2-1/2” diameter chilling coil. All chillers come with a black ABS plastic cover and a remote digital electronic controller which displays temperature, set point in either ºF (±1º) or ºC, mounted in a NEMA enclosure. All chillers will be factory set to operate most efficiently at your specified cooling temperature. You must specify at time of order. All units have been pretested and have 60-Hz motors with 4’ power cords. 1/4 & 1/3-hp chillers ship Ground. Larger sizes ship motor freight. All prices FOB CA. Most units ship in 48 hours. Use the chart in Tech Talk 59 to determine the horsepower required for your application. Two-year warranty. • No Plumbing Required, Drop titanium coil directly into tank or sump• Fresh or Saltwater Use • Compact Design and Quiet Operation• Remote Electronic Temperature Controller • Ozone Friendly Refrigerant (134A)

Standard ModelsOperate within a temperature range of 65–80ºF (18–27ºC) for applications such as reef tanks and warm water fish exhibits.

Option A ModelsOperate within a temperature range of 50–65ºF (10–18ºC) for bait fish and temperate fish exhibits.

AE3D

2-YEAR WARRANTY

Cyclone® registered trademark of Aqua Logic, Inc.

COOLWORKS ICE PROBE® COOLING ELEMENTThe Coolworks Ice Probe uses advanced thermoelectric technology to directly convert electricity into cooling power. Its unique design is based upon Peltier’s principle, making the Ice Probe a highly efficient miniature heat pump! The durable aluminum probe is coated with an FDA-approved epoxy, making these units ideal small coolers for miniature aquariums, bait tanks, bioassay research, hydroponics and even potable water systems. The units are capable of cooling 10 gallons of water 20°F below ambient temperature in an insulated tank (just a few degrees in a noninsulated tank with heavy lighting). Probes can be mounted through the side of a tank, using the molded bulkhead kit included (11/4” hole required) or can be immersed (probe end only). Temperature controller is not included; we recommend TC11. Weighing only 2 lbs, each Ice Probe includes a separate 12VDC power supply and draws only 50 watts. Ship weight 5 lbs. One-year warranty. • Efficient—directly converts electricity into cooling• Reliable—fan is only moving part• Easy to install—one hole, one nut• Safe—low-voltage operation• Environmentally friendly—no chemicals or gases• Can use temperature controller

MODEL EACH

AE9 $140.69

Ice Probe® is a registered trademark of Ulf Moren.

Page 15: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

258 CHILLERSWater Chillers

Delta Star®, Cyclone® and Aqua Logic® are registered trademarks of Aqua Logic, Inc. Teco® and SeaChill® are trademarks and/or registered trademarks of Teco Srl.

FLOW-THROUGH STYLE DROP-IN COIL STYLE

2-YEAR WARRANTY

AIR-COOLED TRIMLINE WATER CHILLERS FW SW

These Aqua Logic® TRIMLINE air cooled, titanium water chillers have the same reliable design and features as the Aqua Logic Delta Star® and Cyclone® Chillers but in a more compact package. Titanium is the only heat exchanger material proven to be 100% fish and coral safe in saltwater systems. These sleek chillers have a brushed stainless steel enclosure and ABS panel inserts. They use the helical coil heat exchanger design and include a digital temperature controller mounted with a 4’ cable, remote from the chiller unit. They display temperature, set point, minimum and maximum in °F or °C. A titanium sensor probe with a 6’ cable is included with the controller. Models have 5’ flexible line connecting to a 2-1/2” diameter chilling coil. Ozone Friendly Refrigerant (134A). Two-year warranty. • Fresh or Saltwater Use

• Compact Design & Quiet Operation

• For Indoor Use Only

• Remote Electronic Temperature Controller

Standard Models For applications where the temperature to be maintained is in the range of 65–80ºF (18–27ºC) such as reef tanks and warm water fish exhibits.

Option A Models Cool water units designed for a temperature range of 50–65ºF (10–18ºC) for bait fish and temperate fish exhibits.

60 HZ NOMINAL FLOW (GPM) IN/OUT SHIP WT STANDARD MODELS OPTION A MODELSHP VOLTS BTUH AMPS MIN-MAX L W H FIPT (LBS) MODEL EACH MODEL EACH Delta Star Trimline Flow-Through Models1/4 115 3,000 5.4 8-15 17” 9” 201/2” 3/4” 55 TLD3 $1,049.00 TLD3A $1,199.00

1/3 115 4,000 7.2 10-20 19” 9” 21-1/2” 3/4” 60 TLD4 1,129.00 TLD4A 1,289.00

Cyclone Trimline Drop-In-Coil Models1/4 115 3,000 5.4 8–15 12” 9” 20-1/2” — 55 TLC3 $1,129.00 TLC3A $1,399.001/3 115 4,000 7.2 10–20 15-1/2” 9” 21” — 60 TLC4 1,179.00 TLC4A 1,449.00

SCTR-UV

SCTK150

SCTR-FLOW

SCTK500/SCTK1000/SCTK2000 SCTK3000/SCTK6000

2-YEAR WARRANTY(1/8–1/3 HP MODELS)

BUILT-IN FLOW RATE CAPACITY SHIP WT MODEL HP VOLTS HZ HEATER WATTS (GPM) (GAL) L W H (LBS) EACH

SCTK150 1/8 115 60 — 150 2.5-4.5 UP TO 60 14.2” 8.5” 12.4” 32 $565.99 SCTK500 1/6 115 60 √ 225 3-13 UP TO 120 12.2” 12.2” 16.4” 45 838.99SCTK1000 1/4 115 60 √ 315 3-13 90-200 12.2” 12.2” 18 50 943.99SCTK2000 1/3 115 60 √ 440 3-13 130-150 12.2” 12.2” 19.7” 55 1,049.00SCTK3000 1/2 115 60 — 750 4.5-13.5 UP TO 750 23.6” 15.2” 25.6” 85 1,889.00SCTK6000 1 115 60 — 900 4.5-13.5 UP TO 1,300 23.6” 15.2” 25.6” 90 2,414.00SCTR-FLOW FLOW INDICATOR 1 9.49SCTR-HEAT HEATER KIT FOR MODELS SCTK3000 AND SCTK6000 1 88.99SCTR-UV UV KIT FOR MODELS SCTK3000 AND SCTK6000 2 157.49SCTR-UVB UV REPLACEMENT BULB 1 64.79

AQUARIUM CHILLERSEasy to install high-performance units with titanium exchangerGet stable, consistent temperatures from these Teco SEACHILL® Tank aquarium chillers. These chillers are easy to install—barbed in-line connections are included, and no hard plumbing is required.Units have a modern look with sturdy construction and a small footprint. Small and mid-rage units have features that facilitate their placement in tight spaces, cabinets and stands. The digital thermostat with LED display will maintain desired set temperatures within 1°F. Unique to the SCTK150 is a condenser system that also functions as the unit’s chassis—providing an incredible amount of ventilation.On top of the SCTK500, SCTK1000, and SCTK2000 units is a rotatable exhaust conveyor to direct ventilation in any direction. A front-side filter affixes magnetically for effortless maintenance. A built-in heater helps ensure temperatures stay optimal in most use conditions. 2-year warranty on 1/8–1/3 HP models, and 1-year warranty on 1/2 and 1 HP models.

Page 16: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

SECTIONProducts / Products / Products

259SECTIONProducts / Products / Products

259

7WC w/ Cover

5hp water chiller installation.

7WC w/o Cover

60 HZ NOMINAL FLOW (GPM) *CONDENSER WATER WATER IN/OUT SHIP WT MODEL HP VOLTS BTUH KW AMPS MIN-MAX USE (GPM) FPT L W H (LBS) EACH

3WC 1/4 115 3,000 0.9 5.4 8-15 0.3 3/4” 19” 133/4” 11” 65 $1,599.004WC 1/3 115 4,000 1.1 7.2 10-20 0.5 3/4” 221/2” 131/2” 11” 69 1,849.005WC 1/2 115 6,000 1.75 9.5 12-25 0.7 11/2” 24” 151/2” 13” 119 2,399.006WC 1/2 230 6,000 1.75 4.8 12-25 0.7 11/2” 24” 151/2” 13” 119 2,399.007WC 3/4 115 9,000 2.7 13 15-30 1.0 11/2” 25” 21” 15” 150 2,499.008WC 3/4 230 9,000 2.7 7 15-30 1.0 11/2” 25” 21” 15” 150 2,499.009WC 1 230 12,000 3.4 7.2 20-35 1.5 11/2” 27” 24” 15” 160 2,859.0010WC 11/2 230 21,000 6.1 10.5 25-40 2.0 11/2” 31” 26” 19” 250 4,119.00

*Condenser water use based on 55-60˚F water temperature entering the unit. Water flows though unit only when the unit is running.

WATER COOLED WATER CHILLERS FW SW

These Aqua Logic® Delta Star® inline water cooled water chillers have become very popular in the aquaculture and aquarium industries. These models feature water-cooled condensing units, making them ideal for installations with an existing freshwater supply. They use water to cool the condenser instead of air provided by a fan. Sources of cooling water could include a facility’s chilled water loop, municipal water, cooling tower and well or spring water. The chillers’ low heat emission and compact size make them perfect for placement in tight spaces with minimal ventilation. Units include ABS cover, temperature controller and a helix titanium coil. Chillers operate within 40–80ºF (4.5–27ºC). Allow 4 weeks for delivery. Prices are FOB CA, motor freight. One-year warranty.• Fresh or Saltwater Use• In-Line Tube In Shell Titanium Heat Exchanger • Water Cooled Condenser• Compact Design & Quiet Operation• Remote Electronic Temperature Controller • Ozone Friendly Refrigerant (R134A) and model 10WC (R417A)• Larger Sizes Available

259CHILLERSWater Cooled Water Chillers

ECHILL3Chiller Installation and Sizing Tips1. Insulate water lines to and from chillers.2. Insulate as much of the water tank as possible.3. Keep the chiller well ventilated. The higher the temperature around the chiller, the longer it

has to work.4. Submersible water pumps add heat to the water. If a submersible pump must be used, choose

the next size larger chiller.5. Water must be run through the chiller at all times while unit is on.6. For tanks smaller than 3,000 gallons, allow 24 hours for initial chilling.

For tanks larger than 3,000 gallons, allow 48 hours or more.7. Reduce biofouling by filtering water prior to chiller. Check the filter often. If it clogs and

reduces water flow below the minimum required, freeze damage can occur.8. Consult the Pentair AES technical department for flow-through and other applications.9. Ambient air temperature for sizing should be measured directly above the tank to be chilled.10. An oversized chiller will not cost more to operate, as it only turns on when needed and runs

for a shorter time.

TECH TALK 59

Splash aerators, degassing devices, etc., can add a great deal of heat not considered in the above chart. For insulated tanks (at least 2” on all sides), decreased heat loss will require less hp.

Temperature Difference From Ambient (Fº)Hp 10 20 30 401/6 90 45 30 231/5 144 72 50 401/4 260 130 90 701/3 360 181 130 1001/2 550 280 200 1543/4 826 420 300 2311 1,321 672 500 370

11/2 2,115 1,075 800 5552 2,640 1,320 850 6703 3,960 1,980 1,275 1,0054 5,280 2,640 1,700 1,3405 6,600 3,300 2,125 1,6758 10,560 5,280 3,400 2,68010 13,200 6,600 4,250 3,350

Pentair AES Chiller Sizing Chart (in Gallons of Water Cooled) for Uninsulated Tanks

Page 17: HEATERS/CHILLERS PRODUCTS...Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788 244 SECTION Products / Products / Products 244 PRODUCTS 245mmersion Heaters I

Online Orders: PentairAES.com I Phone Orders and Tech Advice: 877.347.4788

260 SECTIONProducts / Products / Products

260 SECTIONProducts / Products / Products

2 - 5HP models1/3 - 1HP models

CHILLER BARREL PACKAGESAqua Logic® DX (Direct Expansion) Heat Exchanger Packages are complete refrigerant-to-water systems that are safe for both fresh and salt water systems. The heat exchanger can be connected to a central refrigerant loop or to a dedicated remote condensing unit. These packages are ideal for overseas installations where the condensing unit can be purchased and serviced locally saving significant freight and importation costs. Nominal BTU capacity is based on using R-134A refrigerant (for models HX-3DX thru HX-12DX) or R-410A refrigerant (for models HX-24DX and larger). If another type of refrigerant will be used, please consult us before ordering. Ship via motor freight. FOB CA. One-year limited warranty.• Preassembled and ready to install• Compact design• Titanium tube and Schedule 40 PVC shell evaporator• 304 stainless steel mounting stand and hardware• Digital temperature controller, TXV, flow switch, moisture indicator • 24 volt power supply requiredCondensing units are also available for each DX Heat Exchanger Package, please refer to the Aqua Logic® Multi-Temp® Air Cooled Water Chillers or Aqua Logic® Titan Air Cooled Heat Pumps and request a “Split” option.NOTE: Standard DX heat exchangers are manufactured for connection to cooling-only condensing units and WILL NOT work with a heat pump condensing unit. If being used with a heat pump condensing unit, add “-HP” to part number (call for pricing).

NOMINAL FLOW (GPM) REFRIGERANT PROCESS WATER SHIP WT MODEL HP BTUH* KW MIN/MAX IN/OUT FIPT IN/OUT L W H (LBS) EACH

HX-3DX 1/4 3,000 0.8 8 / 15 1 @ 3/8” / 3/8” 3/4” FIPT 23” 7” 18” 25 $1,054.00 HX-4DX 1/3 4,000 1.2 10 / 20 1 @ 3/8” / 3/8” 3/4” FIPT 25” 7” 18” 28 1,076.00HX-6DX 1/2 6,000 1.8 12 / 25 1 @ 3/8” / 1/2” 11/2” FIPT 26” 7” 18” 30 1,098.00HX-9DX 3/4 9,500 2.6 20 / 35 1 @ 3/8” / 1/2” 11/2” FIPT 32” 7” 18” 35 1,276.00HX-12DX 1 12,000 3.5 25 / 40 1 @ 3/8” / 5/8” 11/2” FIPT 35” 7” 18” 38 1,465.00HX-24DX 2 24,000 7.0 20 / 40 1 @ 3/8” / 5/8” 2” SLIP 29” 14” 26” 129 2,877.00HX-36DX 3 36,000 10.5 20 / 40 1 @ 3/8” / 5/8” 2” SLIP 36” 14” 26” 148 3,196.00HX-48DX 4 48,000 14.0 30 / 60 1 @ 3/8” / 11/8” 2” SLIP 45” 14” 26” 174 3,380.00HX-60DX 5 60,000 17.5 30 / 60 1 @ 3/8” / 11/8” 2” SLIP 52” 14” 26” 194 3,699.00HX-90DX 7.5 90,000 28.0 100 / 180 1 @ 5/8” / 13/8” 3” SLIP 20” 25” 52” 216 6,873.00HX-120DX 10 120,000 35.0 100 / 180 1 @ 5/8” / 13/8” 3” SLIP 20” 25” 62” 253 8,275.00HX-180DX 15 175,000 51.2 100 / 180 1 @ 5/8” / 15/8” 3” SLIP 20” 25” 80” 302 10,579.00HX-240DX 20 223,000 65.3 100 / 180 2 @ 1/2” / 13/8” 3” SLIP 20” 25” 92” 337 13,599.00

*For models HX-3DX thru HX-12DX, nominal BTUH is based on 134A refrigerant. For models HX-24DX and larger, nominal BTUH is based on R410A refrigerant.

7.5 - 20HP models

260 SECTIONProducts / Products / Products

260 CHILLERSChiller Barrel Packages