177
©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 JBS&G (55291-118163) 25 September 2018 Zaman Shamsuz Randwick City Council Via email: [email protected] AMR001 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW Dear Zaman, Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 24 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures. All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in: Work, Health and Safety (2017) Regulation; and Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos. ----------------------------------------- Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected]. Yours sincerely: Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

Guidance Note on the Membrane Filter Method for Estimating ... · Description Testing Site Extracted Holding Time Asbestos - LTM-ASB-8010 Sydney Sep 24, 2018 Indefinite Asbestos -

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118163)

25 September 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR001 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 24 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 619284-AFCProject Name MAROUBRAProject ID 55291Received Date Sep 24, 2018Date Reported Sep 24, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 619284-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Sep 24, 2018Report 619284-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Se31809 DE295122 AC044 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:20 14:30 1.0 1.0 0/100 < 0.01

18-Se31810 DE295092 AC046 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:22 14:32 1.0 1.0 0/100 < 0.01

18-Se31811 DE295121 AC051 SOUTH EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:24 14:34 1.0 1.0 0/100 < 0.01

18-Se31812 DE295171 AC090 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:26 14:36 1.0 1.0 0/100 < 0.01

18-Se31813 DE295087 AC100 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:28 14:38 1.0 1.0 0/100 < 0.01

18-Se31814 DE295097 AC105 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:30 14:40 1.0 1.0 0/100 < 0.01

18-Se31815 DE295069 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 619284-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Sep 24, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Sep 24, 2018 Indefinite

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 619284-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Sep 24, 2018 5:38 PMAddress: Level 1, 50 Margaret St Report #: 619284 Due: Sep 24, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE295122 Sep 24, 2018 2:30PM Air S18-Se31809 X

2 DE295092 Sep 24, 2018 2:32PM Air S18-Se31810 X

3 DE295121 Sep 24, 2018 2:34PM Air S18-Se31811 X

4 DE295171 Sep 24, 2018 2:36PM Air S18-Se31812 X

5 DE295087 Sep 24, 2018 2:38PM Air S18-Se31813 X

6 DE295097 Sep 24, 2018 2:40PM Air S18-Se31814 X

7 DE295069 Sep 24, 2018 Air S18-Se31815 X

Test Counts 7

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 619284-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 619284-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident N/A

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Sep 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 619284-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118202)

26 September 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR002 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 25 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 619526-AFCProject Name MAROUBRAProject ID 55291Received Date Sep 25, 2018Date Reported Sep 25, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 619526-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Sep 25, 2018Report 619526-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Se33607 DE295073 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:10 14:30 1.0 1.0 0/100 < 0.01

18-Se33608 DE295105 AC046 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:12 14:32 1.0 1.0 3/100 < 0.01

18-Se33609 DE295107 AC051 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:14 14:34 1.0 1.0 0/100 < 0.01

18-Se33610 DE295104 AC090 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:16 14:36 1.0 1.0 0/100 < 0.01

18-Se33611 DE295090 AC100 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:18 14:38 1.0 1.0 0/100 < 0.01

18-Se33612 DE295094 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:20 14:40 1.0 1.0 0/100 < 0.01

18-Se33613 DE295062 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 619526-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Sep 25, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Sep 25, 2018 Indefinite

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 619526-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Sep 25, 2018 5:51 PMAddress: Level 1, 50 Margaret St Report #: 619526 Due: Sep 25, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE295073 Sep 25, 2018 2:30PM Air S18-Se33607 X

2 DE295105 Sep 25, 2018 2:32PM Air S18-Se33608 X

3 DE295107 Sep 25, 2018 2:34PM Air S18-Se33609 X

4 DE295104 Sep 25, 2018 2:36PM Air S18-Se33610 X

5 DE295090 Sep 25, 2018 2:38PM Air S18-Se33611 X

6 DE295094 Sep 25, 2018 2:40PM Air S18-Se33612 X

7 DE295062 Sep 25, 2018 Air S18-Se33613 X

Test Counts 7

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 619526-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 619526-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Sep 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 619526-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118218)

27 September 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR003 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 26 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 619738-AFCProject Name MAROUBRAProject ID 55291Received Date Sep 26, 2018Date Reported Sep 26, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 619738-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Sep 26, 2018Report 619738-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Se35020 DE295068 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:00 14:30 1.0 1.0 0/100 < 0.01

18-Se35021 DE295075 AC046 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:02 14:32 1.0 1.0 0/100 < 0.01

18-Se35022 DE295058 AC051 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:04 14:34 1.0 1.0 0/100 < 0.01

18-Se35023 DE295061 AC090 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:06 14:36 1.0 1.0 1/100 < 0.01

18-Se35024 DE295066 AC100 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:08 14:38 1.0 1.0 0/100 < 0.01

18-Se35025 DE295079 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:10 14:40 1.0 1.0 0/100 < 0.01

18-Se35026 DE295113 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 619738-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Sep 26, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Sep 26, 2018 Indefinite

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 619738-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Sep 26, 2018 5:06 PMAddress: Level 1, 50 Margaret St Report #: 619738 Due: Sep 26, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE295068 Sep 26, 2018 2:30PM Air S18-Se35020 X

2 DE295075 Sep 26, 2018 2:32PM Air S18-Se35021 X

3 DE295058 Sep 26, 2018 2:34PM Air S18-Se35022 X

4 DE295061 Sep 26, 2018 2:36PM Air S18-Se35023 X

5 DE295066 Sep 26, 2018 2:38PM Air S18-Se35024 X

6 DE295079 Sep 26, 2018 2:40PM Air S18-Se35025 X

7 DE295113 Sep 26, 2018 Air S18-Se35026 X

Test Counts 7

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 619738-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 619738-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident N/A

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Sep 26, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 619738-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118244)

28 September 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR004 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 27 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 619980-AFCProject Name MAROUBRAProject ID 55291Received Date Sep 27, 2018Date Reported Sep 27, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 619980-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Sep 27, 2018Report 619980-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Se36640 DE293277 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:15 14:30 1.0 1.0 1/100 < 0.01

18-Se36641 DE295096 AC046 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:17 14:32 1.0 1.0 1/100 < 0.01

18-Se36642 DE293281 AC051 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:19 14:34 1.0 1.0 0/100 < 0.01

18-Se36643 DE295095 AC090 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:21 14:36 1.0 1.0 0/100 < 0.01

18-Se36644 DE295093 AC100 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:23 14:38 1.0 1.0 0/100 < 0.01

18-Se36645 DE295098 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:25 14:40 1.0 1.0 0/100 < 0.01

18-Se36646 DE293284 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 619980-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Sep 27, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Sep 27, 2018 Indefinite

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 619980-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Sep 27, 2018 6:05 PMAddress: Level 1, 50 Margaret St Report #: 619980 Due: Sep 27, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE293277 Sep 27, 2018 2:30PM Air S18-Se36640 X

2 DE295096 Sep 27, 2018 2:32PM Air S18-Se36641 X

3 DE293281 Sep 27, 2018 2:34PM Air S18-Se36642 X

4 DE295095 Sep 27, 2018 2:36PM Air S18-Se36643 X

5 DE295093 Sep 27, 2018 2:38PM Air S18-Se36644 X

6 DE295098 Sep 27, 2018 2:40PM Air S18-Se36645 X

7 DE293284 Sep 27, 2018 Air S18-Se36646 X

Test Counts 7

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 619980-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 619980-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Sep 27, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 619980-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118281)

2 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR005 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 28 September 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 620121-AFCProject Name MAROUBRAProject ID 55291Received Date Sep 28, 2018Date Reported Sep 28, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 620121-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Sep 28, 2018Report 620121-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Se37399 DE293337 AC042 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:10 13:10 1.5 1.5 0/100 < 0.01

18-Se37400 DE293305 AC044 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:12 13:12 1.5 1.5 0/100 < 0.01

18-Se37401 DE293311 AC046 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:14 13:14 1.5 1.5 0/100 < 0.01

18-Se37402 DE293279 AC051 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:16 13:16 1.5 1.5 0/100 < 0.01

18-Se37403 DE293368 AC090 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:18 13:18 1.5 1.5 0/100 < 0.01

18-Se37404 DE293702 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:20 13:20 1.5 1.5 0/100 < 0.01

18-Se37405 DE293709 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 620121-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Sep 28, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Sep 28, 2018 Indefinite

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 620121-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Sep 28, 2018 6:40 PMAddress: Level 1, 50 Margaret St Report #: 620121 Due: Sep 28, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE293337 Sep 28, 2018 1:10PM Air S18-Se37399 X

2 DE293305 Sep 28, 2018 1:12PM Air S18-Se37400 X

3 DE293311 Sep 28, 2018 1:14PM Air S18-Se37401 X

4 DE293279 Sep 28, 2018 1:16PM Air S18-Se37402 X

5 DE293368 Sep 28, 2018 1:18PM Air S18-Se37403 X

6 DE293702 Sep 28, 2018 1:20PM Air S18-Se37404 X

7 DE293709 Sep 28, 2018 Air S18-Se37405 X

Test Counts 7

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 620121-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 620121-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Sep 28, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 620121-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118311)

3 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR006 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 2 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 620530-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 02, 2018Date Reported Oct 02, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 620530-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 02, 2018Report 620530-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc02203 DE293282 AC042 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc02204 DE293314 AC044 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc02205 DE293280 AC046 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc02206 DE293301 AC051 SOUTH WEST BOUNDARY OF FENCED OFF AREA PARK SIDE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc02207 DE293270 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc02208 DE293476 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc02209 DE293296 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 620530-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 02, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 02, 2018 Indefinite

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 620530-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 2, 2018 5:15 PMAddress: Level 1, 50 Margaret St Report #: 620530 Due: Oct 2, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE293282 Oct 02, 2018 2:00PM Air S18-Oc02203 X

2 DE293314 Oct 02, 2018 2:02PM Air S18-Oc02204 X

3 DE293280 Oct 02, 2018 2:04PM Air S18-Oc02205 X

4 DE293301 Oct 02, 2018 2:06PM Air S18-Oc02206 X

5 DE293270 Oct 02, 2018 2:08PM Air S18-Oc02207 X

6 DE293476 Oct 02, 2018 2:10PM Air S18-Oc02208 X

7 DE293296 Oct 02, 2018 Air S18-Oc02209 X

Test Counts 7

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 620530-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 620530-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Authorised by:

Nibha Vaidya Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 02, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 620530-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118312)

4 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR007 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 3 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 620763-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 03, 2018Date Reported Oct 03, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 620763-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 03, 2018Report 620763-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc03977 DE293519 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc03978 DE293354 AC046 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc03979 DE293438 AC051 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc03980 DE293290 AC053 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc03981 DE293289 AC090 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc03982 DE294723 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc03983 DE293265 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 620763-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 03, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 03, 2018 Indefinite

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 620763-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 3, 2018 6:05 PMAddress: Level 1, 50 Margaret St Report #: 620763 Due: Oct 3, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE293519 Oct 03, 2018 2:00PM Air S18-Oc03977 X

2 DE293354 Oct 03, 2018 2:02PM Air S18-Oc03978 X

3 DE293438 Oct 03, 2018 2:04PM Air S18-Oc03979 X

4 DE293290 Oct 03, 2018 2:06PM Air S18-Oc03980 X

5 DE293289 Oct 03, 2018 2:08PM Air S18-Oc03981 X

6 DE294723 Oct 03, 2018 2:10PM Air S18-Oc03982 X

7 DE293265 Oct 03, 2018 Air S18-Oc03983 X

Test Counts 7

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 620763-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 620763-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 03, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 620763-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118386)

5 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR008 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 4 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 621010-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 04, 2018Date Reported Oct 04, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 621010-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 04, 2018Report 621010-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc05845 DE295298 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:10 14:00 1.0 1.0 0/100 < 0.01

18-Oc05846 DE295332 AC046 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:12 14:02 1.0 1.0 0/100 < 0.01

18-Oc05847 DE295282 AC051 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:14 14:04 1.0 1.0 0/100 < 0.01

18-Oc05848 DE295289 AC053 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:16 14:06 1.0 1.0 0/100 < 0.01

18-Oc05849 DE295295 AC090 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:18 14:08 1.0 1.0 0/100 < 0.01

18-Oc05850 DE295318 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:20 14:10 1.0 1.0 0/100 < 0.01

18-Oc05851 DE295357 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 621010-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 04, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 04, 2018 Indefinite

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 621010-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 4, 2018 5:52 PMAddress: Level 1, 50 Margaret St Report #: 621010 Due: Oct 4, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE295298 Oct 04, 2018 2:00PM Air S18-Oc05845 X

2 DE295332 Oct 04, 2018 2:02PM Air S18-Oc05846 X

3 DE295282 Oct 04, 2018 2:04PM Air S18-Oc05847 X

4 DE295289 Oct 04, 2018 2:06PM Air S18-Oc05848 X

5 DE295295 Oct 04, 2018 2:08PM Air S18-Oc05849 X

6 DE295318 Oct 04, 2018 2:10PM Air S18-Oc05850 X

7 DE295357 Oct 04, 2018 Air S18-Oc05851 X

Test Counts 7

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 621010-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 621010-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 04, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 621010-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118440)

9 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR009 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 8 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 621480-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 08, 2018Date Reported Oct 08, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 621480-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 08, 2018Report 621480-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc09113 DE295507 AC044 NORTH BOUNDARY OF FENCED AREA PARK SIDE 7:10 14:00 1.0 1.0 0/100 < 0.01

18-Oc09114 DE295301 AC051 NORTH WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:12 14:02 1.0 1.0 0/100 < 0.01

18-Oc09115 DE295319 AC046 WEST BOUNDARY OF FENCED AREA MARINE PARADE 7:14 14:04 1.0 1.0 0/100 < 0.01

18-Oc09116 DE295327 AC053 SOUTH WEST BOUNDARY OF FENCED AREA PARK SIDE 7:16 14:06 1.0 1.0 0/100 < 0.01

18-Oc09117 DE295353 AC090 SOUTH BOUNDARY OF FENCED AREA PARK SIDE 7:18 14:08 1.0 1.0 0/100 < 0.01

18-Oc09118 DE295343 AC105 EAST BOUNDARY OF FENCED AREA OCEAN SIDE 7:20 14:10 1.0 1.0 0/100 < 0.01

18-Oc09119 DE295468 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 621480-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 08, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 08, 2018 Indefinite

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 621480-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 8, 2018 5:33 PMAddress: Level 1, 50 Margaret St Report #: 621480 Due: Oct 8, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DE295507 Oct 08, 2018 2:00PM Air S18-Oc09113 X

2 DE295301 Oct 08, 2018 2:02PM Air S18-Oc09114 X

3 DE295319 Oct 08, 2018 2:04PM Air S18-Oc09115 X

4 DE295327 Oct 08, 2018 2:06PM Air S18-Oc09116 X

5 DE295353 Oct 08, 2018 2:08PM Air S18-Oc09117 X

6 DE295343 Oct 08, 2018 2:10PM Air S18-Oc09118 X

7 DE295468 Oct 08, 2018 Air S18-Oc09119 X

Test Counts 7

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 621480-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 621480-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 08, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 621480-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118472)

10 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR010 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 9 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 621670-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 09, 2018Date Reported Oct 09, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 621670-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 09, 2018Report 621670-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc10373 DD125893 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:10 14:00 1.0 1.0 0/100 < 0.01

18-Oc10374 DD125838 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:12 14:02 1.0 1.0 0/100 < 0.01

18-Oc10375 DD125859 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:14 14:04 1.0 1.0 0/100 < 0.01

18-Oc10376 DD125858 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:16 14:06 1.0 1.0 0/100 < 0.01

18-Oc10377 DD125816 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:18 14:08 1.0 1.0 0/100 < 0.01

18-Oc10378 DD125826 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:20 14:10 1.0 1.0 0/100 < 0.01

18-Oc10379 DD298408 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 621670-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 09, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 09, 2018 Indefinite

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 621670-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 9, 2018 5:12 PMAddress: Level 1, 50 Margaret St Report #: 621670 Due: Oct 9, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125893 Oct 09, 2018 2:00PM Air S18-Oc10373 X

2 DD125838 Oct 09, 2018 2:02PM Air S18-Oc10374 X

3 DD125859 Oct 09, 2018 2:04PM Air S18-Oc10375 X

4 DD125858 Oct 09, 2018 2:06PM Air S18-Oc10376 X

5 DD125816 Oct 09, 2018 2:08PM Air S18-Oc10377 X

6 DD125826 Oct 09, 2018 2:10PM Air S18-Oc10378 X

7 DD298408 Oct 09, 2018 Air S18-Oc10379 X

Test Counts 7

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 621670-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Where a moisture has been determined on a solid sample the result is expressed on a dry basis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Western Australia Department of Health

NOHSC National Occupational Health and Safety Commission

ACM Bonded asbestos-containing material means any material containing more than 1% asbestos and comprises asbestos-containing-material which is in sound condition,

although possibly broken or fragmented, and where the asbestos is bound in a matrix such as cement or resin. Common examples of ACM include but are not limited

to: pipe and boiler insulation, sprayed-on fireproofing, troweled-on acoustical plaster, floor tile and mastic, floor linoleum, transite shingles, roofing materials, wall and

ceiling plaster, ceiling tiles, and gasket materials. This term is restricted to material that cannot pass a 7 mm x 7 mm sieve. This sieve size is selected because it

approximates the thickness of common asbestos cement sheeting and for fragments to be smaller than this would imply a high degree of damage and hence potential

for fibre release.

FA FA comprises friable asbestos material and includes severely weathered cement sheet, insulation products and woven asbestos material. This type of friable asbestos

is defined here as asbestos material that is in a degraded condition such that it can be broken or crumbled by hand pressure. This material is typically unbonded or

was previously bonded and is now significantly degraded (crumbling).

PACM Presumed Asbestos-Containing Material means thermal system insulation and surfacing material found in buildings, vessels, and vessel sections constructed no later

than 1980 that are assumed to contain greater than one percent asbestos but have not been sampled or analyzed to verify or negate the presence of asbestos.

AF Asbestos fines (AF) are defined as free fibres, or fibre bundles, smaller than 7mm. It is the free fibres which present the greatest risk to human health, although very

small fibres (< 5 microns in length) are not considered to be such a risk. AF also includes small fragments of bonded ACM that pass through a 7 mm x 7 mm sieve.

(Note that for bonded ACM fragments to pass through a 7 mm x 7 mm sieve implies a substatntial degree of damage which increases the potential for fibre release.)

AC Asbestos cement means a mixture of cement and asbestos fibres (typically 90:10 ratios).

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 621670-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident N/A

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 09, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 621670-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118495)

11 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR011 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 10 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 621861-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 10, 2018Date Reported Oct 10, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 621861-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 10, 2018Report 621861-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc11784 DD125870 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 13:00 1.5 1.5 0/100 < 0.01

18-Oc11785 DD125864 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 13:02 1.5 1.5 0/100 < 0.01

18-Oc11786 DD125823 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 13:04 1.5 1.5 0/100 < 0.01

18-Oc11787 DD125831 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 13:06 1.5 1.5 0/100 < 0.01

18-Oc11788 DD125828 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 13:08 1.5 1.5 0/100 < 0.01

18-Oc11789 DD125880 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 13:10 1.5 1.5 0/100 < 0.01

18-Oc11790 DD125861 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 621861-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 10, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 10, 2018 Indefinite

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 621861-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 10, 2018 5:20 PMAddress: Level 1, 50 Margaret St Report #: 621861 Due: Oct 10, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125870 Oct 10, 2018 1:00PM Air S18-Oc11784 X

2 DD125864 Oct 10, 2018 1:02PM Air S18-Oc11785 X

3 DD125823 Oct 10, 2018 1:04PM Air S18-Oc11786 X

4 DD125831 Oct 10, 2018 1:06PM Air S18-Oc11787 X

5 DD125828 Oct 10, 2018 1:08PM Air S18-Oc11788 X

6 DD125880 Oct 10, 2018 1:10PM Air S18-Oc11789 X

7 DD125861 Oct 10, 2018 Air S18-Oc11790 X

Test Counts 7

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 621861-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”)

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability)

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 621861-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 10, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 621861-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118506)

12 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR012 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 11 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 622138-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 11, 2018Date Reported Oct 11, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 622138-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 11, 2018Report 622138-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc13908 DD125902 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:10 14:00 1.0 1.0 0/100 < 0.01

18-Oc13909 DD125844 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:12 14:02 1.0 1.0 0/100 < 0.01

18-Oc13910 DD125853 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:14 14:04 1.0 1.0 0/100 < 0.01

18-Oc13911 DD125814 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:16 14:06 1.0 1.0 0/100 < 0.01

18-Oc13912 DD125860 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:18 14:08 1.0 1.0 0/100 < 0.01

18-Oc13913 DD125825 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:20 14:10 1.0 1.0 0/100 < 0.01

18-Oc13914 DE295364 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 622138-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 11, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 11, 2018 Indefinite

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 622138-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 11, 2018 6:00 PMAddress: Level 1, 50 Margaret St Report #: 622138 Due: Oct 11, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125902 Oct 11, 2018 2:00PM Air S18-Oc13908 X

2 DD125844 Oct 11, 2018 2:02PM Air S18-Oc13909 X

3 DD125853 Oct 11, 2018 2:04PM Air S18-Oc13910 X

4 DD125814 Oct 11, 2018 2:06PM Air S18-Oc13911 X

5 DD125860 Oct 11, 2018 2:08PM Air S18-Oc13912 X

6 DD125825 Oct 11, 2018 2:10PM Air S18-Oc13913 X

7 DE295364 Oct 11, 2018 Air S18-Oc13914 X

Test Counts 7

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 622138-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 622138-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 11, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 622138-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118541)

15 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR013 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 12 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 622335-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 12, 2018Date Reported Oct 12, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 622335-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 12, 2018Report 622335-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc15586 DD125837 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc15587 DD125827 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc15588 DD125815 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc15589 DD125836 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc15590 DD125881 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc15591 DD125829 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc15592 DD125788 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 622335-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 12, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 12, 2018 Indefinite

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 622335-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 12, 2018 5:00 PMAddress: Level 1, 50 Margaret St Report #: 622335 Due: Oct 12, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125837 Oct 12, 2018 2:00PM Air S18-Oc15586 X

2 DD125827 Oct 12, 2018 2:02PM Air S18-Oc15587 X

3 DD125815 Oct 12, 2018 2:04PM Air S18-Oc15588 X

4 DD125836 Oct 12, 2018 2:06PM Air S18-Oc15589 X

5 DD125881 Oct 12, 2018 2:08PM Air S18-Oc15590 X

6 DD125829 Oct 12, 2018 2:10PM Air S18-Oc15591 X

7 DD125788 Oct 12, 2018 Air S18-Oc15592 X

Test Counts 7

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 622335-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 622335-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 12, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 622335-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118573)

16 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR014 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 15 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 622559-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 15, 2018Date Reported Oct 15, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 622559-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 15, 2018Report 622559-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc17412 DD125873 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc17413 DD125824 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc17414 DD125832 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc17415 DD125830 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc17416 DD125819 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc17417 DD125806 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc17418 DD125786 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 622559-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 15, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 15, 2018 Indefinite

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 622559-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 15, 2018 5:05 PMAddress: Level 1, 50 Margaret St Report #: 622559 Due: Oct 15, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125873 Oct 15, 2018 2:00PM Air S18-Oc17412 X

2 DD125824 Oct 15, 2018 2:02PM Air S18-Oc17413 X

3 DD125832 Oct 15, 2018 2:04PM Air S18-Oc17414 X

4 DD125830 Oct 15, 2018 2:06PM Air S18-Oc17415 X

5 DD125819 Oct 15, 2018 2:08PM Air S18-Oc17416 X

6 DD125806 Oct 15, 2018 2:10PM Air S18-Oc17417 X

7 DD125786 Oct 15, 2018 Air S18-Oc17418 X

Test Counts 7

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 622559-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 622559-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 15, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 622559-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118579)

17 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR015 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 16 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures. Please note, sample ID 18-Oc19020;DD125839 reported a concentration of respirable fibres in air of 0.02 fibres/mL for the sampling period indicated. This exceeds the upper action level for control monitoring of less than 0.02 fibres/mL as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

The sample has been forwarded for additional analysis to determine the composition of identified respirable fibres via Scanning Electron Microscopy (SEM) analysis.

All other reported results were satisfactory and below the minimum action level for control monitoring.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 622766-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 16, 2018Date Reported Oct 16, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 622766-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 16, 2018Report 622766-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc19020 DD125839 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:10 14:10 1.0 1.0 16/100 0.02

18-Oc19021 DD125840 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:12 14:12 1.0 1.0 1/100 < 0.01

18-Oc19022 DD125835 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:14 14:14 1.0 1.0 1/100 < 0.01

18-Oc19023 DD125805 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:16 14:16 1.0 1.0 0/100 < 0.01

18-Oc19024 DD125812 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:18 14:18 1.0 1.0 2/100 < 0.01

18-Oc19025 DD125818 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:20 14:20 1.0 1.0 0/100 < 0.01

18-Oc19026 DD125885 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 622766-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 16, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 16, 2018 Indefinite

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 622766-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 16, 2018 5:19 PMAddress: Level 1, 50 Margaret St Report #: 622766 Due: Oct 16, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125839 Oct 16, 2018 2:10PM Air S18-Oc19020 X

2 DD125840 Oct 16, 2018 2:12PM Air S18-Oc19021 X

3 DD125835 Oct 16, 2018 2:14PM Air S18-Oc19022 X

4 DD125805 Oct 16, 2018 2:16PM Air S18-Oc19023 X

5 DD125812 Oct 16, 2018 2:18PM Air S18-Oc19024 X

6 DD125818 Oct 16, 2018 2:20PM Air S18-Oc19025 X

7 DD125885 Oct 16, 2018 Air S18-Oc19026 X

Test Counts 7

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 622766-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 622766-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 16, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 622766-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118619)

18 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR016 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 17 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 622977-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 17, 2018Date Reported Oct 17, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 622977-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 17, 2018Report 622977-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc20411 DD125976 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc20412 DD126001 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc20413 DD125992 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 1/100 < 0.01

18-Oc20414 DD126003 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 1/100 < 0.01

18-Oc20415 DD125997 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc20416 DD125979 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc20417 DD132002 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 622977-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 17, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 17, 2018 Indefinite

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 622977-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 17, 2018 5:23 PMAddress: Level 1, 50 Margaret St Report #: 622977 Due: Oct 17, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125976 Oct 17, 2018 2:00PM Air S18-Oc20411 X

2 DD126001 Oct 17, 2018 2:02PM Air S18-Oc20412 X

3 DD125992 Oct 17, 2018 2:04PM Air S18-Oc20413 X

4 DD126003 Oct 17, 2018 2:06PM Air S18-Oc20414 X

5 DD125997 Oct 17, 2018 2:08PM Air S18-Oc20415 X

6 DD125979 Oct 17, 2018 2:10PM Air S18-Oc20416 X

7 DD132002 Oct 17, 2018 Air S18-Oc20417 X

Test Counts 7

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 622977-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 622977-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident N/A

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted No

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 17, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 622977-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118659)

19 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR017 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 18 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Michael SamuelReport 623234-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 18, 2018Date Reported Oct 18, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 623234-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 18, 2018Report 623234-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc22178 DD126013 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc22179 DD125974 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 2/100 < 0.01

18-Oc22180 DD125988 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 2/100 < 0.01

18-Oc22181 DD125975 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc22182 DD125973 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc22183 DD125994 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc22184 DD126009 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 623234-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 18, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 18, 2018 Indefinite

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 623234-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 18, 2018 5:55 PMAddress: Level 1, 50 Margaret St Report #: 623234 Due: Oct 18, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Michael Samuel

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD126013 Oct 18, 2018 2:00PM Air S18-Oc22178 X

2 DD125974 Oct 18, 2018 2:02PM Air S18-Oc22179 X

3 DD125988 Oct 18, 2018 2:04PM Air S18-Oc22180 X

4 DD125975 Oct 18, 2018 2:06PM Air S18-Oc22181 X

5 DD125973 Oct 18, 2018 2:08PM Air S18-Oc22182 X

6 DD125994 Oct 18, 2018 2:10PM Air S18-Oc22183 X

7 DD126009 Oct 18, 2018 Air S18-Oc22184 X

Test Counts 7

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 623234-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 623234-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 18, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 623234-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118670)

22 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR018 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 19 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 623499-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 19, 2018Date Reported Oct 19, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 623499-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 19, 2018Report 623499-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc24324 DD126006 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 6:30 14:00 1.0 1.0 0/100 < 0.01

18-Oc24325 DD125986 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 6:32 14:02 1.0 1.0 0/100 < 0.01

18-Oc24326 DD125977 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 6:34 14:04 1.0 1.0 0/100 < 0.01

18-Oc24327 DD126005 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 6:36 14:06 1.0 1.0 0/100 < 0.01

18-Oc24328 DD125987 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 6:38 14:08 1.0 1.0 0/100 < 0.01

18-Oc24329 DD125982 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 6:40 14:10 1.0 1.0 0/100 < 0.01

18-Oc24330 DD125984 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 623499-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 19, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 19, 2018 Indefinite

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 623499-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 19, 2018 6:15 PMAddress: Level 1, 50 Margaret St Report #: 623499 Due: Oct 19, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD126006 Oct 19, 2018 2:00PM Air S18-Oc24324 X

2 DD125986 Oct 19, 2018 2:02PM Air S18-Oc24325 X

3 DD125977 Oct 19, 2018 2:04PM Air S18-Oc24326 X

4 DD126005 Oct 19, 2018 2:06PM Air S18-Oc24327 X

5 DD125987 Oct 19, 2018 2:08PM Air S18-Oc24328 X

6 DD125982 Oct 19, 2018 2:10PM Air S18-Oc24329 X

7 DD125984 Oct 19, 2018 Air S18-Oc24330 X

Test Counts 7

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 623499-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 623499-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 19, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 623499-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118707)

23 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR019 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 22 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 623761-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 22, 2018Date Reported Oct 22, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 623761-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 22, 2018Report 623761-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc26309 DD126011 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc26310 DD125995 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 8/100 < 0.01

18-Oc26311 DD125968 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc26312 DD125990 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc26313 DD125978 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 1/100 < 0.01

18-Oc26314 DD126007 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 3/100 < 0.01

18-Oc26315 DD126000 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 623761-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 22, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 22, 2018 Indefinite

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 623761-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 22, 2018 5:21 PMAddress: Level 1, 50 Margaret St Report #: 623761 Due: Oct 22, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD126011 Oct 22, 2018 2:00PM Air S18-Oc26309 X

2 DD125995 Oct 22, 2018 2:02PM Air S18-Oc26310 X

3 DD125968 Oct 22, 2018 2:04PM Air S18-Oc26311 X

4 DD125990 Oct 22, 2018 2:06PM Air S18-Oc26312 X

5 DD125978 Oct 22, 2018 2:08PM Air S18-Oc26313 X

6 DD126007 Oct 22, 2018 2:10PM Air S18-Oc26314 X

7 DD126000 Oct 22, 2018 2:10PM Air S18-Oc26315 X

Test Counts 7

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 623761-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 623761-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 22, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 623761-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118708)

24 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR020 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 23 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 623951-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 23, 2018Date Reported Oct 23, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 623951-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 23, 2018Report 623951-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc27797 DD126004 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc27798 DD126008 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 1/100 < 0.01

18-Oc27799 DD125964 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc27800 DD125970 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc27801 DD125981 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc27802 DD125972 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc27803 DD125971 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 623951-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 23, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 23, 2018 Indefinite

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 623951-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 23, 2018 5:10 PMAddress: Level 1, 50 Margaret St Report #: 623951 Due: Oct 23, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD126004 Oct 23, 2018 2:00PM Air S18-Oc27797 X

2 DD126008 Oct 23, 2018 2:02PM Air S18-Oc27798 X

3 DD125964 Oct 23, 2018 2:04PM Air S18-Oc27799 X

4 DD125970 Oct 23, 2018 2:06PM Air S18-Oc27800 X

5 DD125981 Oct 23, 2018 2:08PM Air S18-Oc27801 X

6 DD125972 Oct 23, 2018 2:10PM Air S18-Oc27802 X

7 DD125971 Oct 23, 2018 Air S18-Oc27803 X

Test Counts 7

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 623951-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 623951-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 23, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 623951-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118786)

25 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR021 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 24 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 624197-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 24, 2018Date Reported Oct 24, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 624197-AFC

6

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 24, 2018Report 624197-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc29684 DD125985 AC044 NORTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc29685 DD125999 AC046 NORTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc29686 DD125996 AC051 WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc29687 DD126002 AC053 SOUTH WEST BOUNDARY OF FENCED OFF AREA MARINE PARADE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc29688 DD126071 AC090 SOUTH BOUNDARY OF FENCED OFF AREA PARK SIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc29689 DD125998 AC105 EAST BOUNDARY OF FENCED OFF AREA OCEAN SIDE 7:10 14:10 1.0 1.0 0/100 < 0.01

18-Oc29690 DD125875 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 624197-AFC

6

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 24, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 24, 2018 Indefinite

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 624197-AFC

6

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 24, 2018 5:15 PMAddress: Level 1, 50 Margaret St Report #: 624197 Due: Oct 24, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD125985 Oct 24, 2018 2:00PM Air S18-Oc29684 X

2 DD125999 Oct 24, 2018 2:02PM Air S18-Oc29685 X

3 DD125996 Oct 24, 2018 2:04PM Air S18-Oc29686 X

4 DD126002 Oct 24, 2018 2:06PM Air S18-Oc29687 X

5 DD126071 Oct 24, 2018 2:08PM Air S18-Oc29688 X

6 DD125998 Oct 24, 2018 2:10PM Air S18-Oc29689 X

7 DD125875 Oct 24, 2018 Air S18-Oc29690 X

Test Counts 7

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 624197-AFC

6

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 624197-AFC

6

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 24, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 624197-AFC

6

Final Report – this report replaces any previously issued Report

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479

JBS&G (55291-118801)

26 October 2018

Zaman Shamsuz Randwick City Council Via email: [email protected]

AMR022 – Daily Airborne Asbestos Fibre Monitoring Report Jack Vanny Reserve, Marine Parade, Maroubra, NSW

Dear Zaman,

Please find as Attachment 1 the daily airborne asbestos fibre monitoring report for works completed at Jack Vanny Reserve, Marine Parade, Maroubra, NSW on 25 October 2018. All air monitoring was completed in accordance with the Guidance Note on the Membrane Filter Method for Estimating Airborne Asbestos Fibres [NOHSC: 3003(2005)], with NATA certification applying to all sample collection, handling and analytical procedures.

All reported results were satisfactory and below the minimum action level of less than 0.01 fibres/mL for control monitoring as outlined in:

• Work, Health and Safety (2017) Regulation; and

• Safework Australia (2016) Code of Practice – How to Safely Remove Asbestos.

-----------------------------------------

Should you require clarification regarding these results, please contact the undersigned on 02 8245 0300 or by email [email protected].

Yours sincerely:

Michael Samuel Licensed Asbestos Assessor (LAA 000157) JBS&G Australia Pty Ltd

©JBS&G Australia Pty Ltd | www.jbsg.com.au | ABN 62 100 220 479 2

Attachment 1 – Daily Airborne Asbestos Fibre Monitoring Report

Certificate of Analysis

JBS & G Australia (NSW) P/LLevel 1, 50 Margaret StSydneyNSW 2000

Attention: Mark HunterReport 624461-AFCProject Name MAROUBRAProject ID 55291Received Date Oct 25, 2018Date Reported Oct 25, 2018

METHODOLOGY:

Asbestos Sampling Sampling as per the National Occupational Health & Safety Commission - GuidanceNote on The Membrane Filter Method For Estimating Airborne Asbestos Fibres 2ndEdition [NOHSC:3003(2005)]

Pump Calibration Defender 520M: Calibrated against National Institute of Standards & Technology (NIST)SOP 13 Standard Operating Procedure for Calibration of Volumetric Ware, GravimetricMethod utilising a 1000 mL burette with a digital stop watch.

Asbestos Counting Conducted in accordance with the National Occupational Health & Safety Commission -Guidance Note on The Membrane Filter Method For Estimating Airborne AsbestosFibres 2nd Edition [NOHSC:3003(2005)] and in-house Method LTM-ASB-8010.

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 1 of

Report Number: 624461-AFC

7

NATA Accredited

Accreditation Number 1261

Site Number 18217

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Project Name MAROUBRAProject ID 55291Date Sampled Oct 25, 2018Report 624461-AFC

Eurofins | mgtSample No.

Client SampleID Pump ID Location Start

(time)End

(time)

Start FlowRate

(L/min)

End FlowRate

(L/min)

Result(Fibres/Fields)

Result(Fibres/mL)

18-Oc31922 DD126012 AC046 NORTH BOUNDARY OF SITE COMPOUND PARK SIDE 7:00 14:00 1.0 1.0 0/100 < 0.01

18-Oc31923 DD125989 AC051 WEST BOUNDARY OF SITE COMPOUND MARINE PARADE 7:02 14:02 1.0 1.0 0/100 < 0.01

18-Oc31924 DD126056 AC090 SOUTH BOUNDARY OF SITE COMPOUND PARK SIDE 7:04 14:04 1.0 1.0 0/100 < 0.01

18-Oc31925 DD125991 AC105 EAST BOUNDARY OF SITE COMPOUND OCEAN SIDE 7:06 14:06 1.0 1.0 0/100 < 0.01

18-Oc31926 DD125980 AC042 NORTH WEST BOUNDARY OF CAR PARK EXCAVATION CAR PARKSIDE 7:08 14:08 1.0 1.0 0/100 < 0.01

18-Oc31927 DD125983 AC048 WEST BOUNDARY OF CAR PARK EXCAVATION AREA CAR PARKSIDE 7:10 14:10 1.0 1.0 2/100 < 0.01

18-Oc31928 DD126486 AC044 WEST BOUNDARY OF PICKING ZONE MARINE PARADE 7:12 14:12 1.0 1.0 0/100 < 0.01

18-Oc31929 DD125993 AC053 SOUTH WEST BOUNDARY OF PICKING ZONE MARINE PARADE 7:14 14:14 1.0 1.0 0/100 < 0.01

18-Oc31930 DD126014 BLANK BLANK -- -- -- -- 0/100 --

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 2 of

Report Number: 624461-AFC

7

Accredited for compliance with ISO/IEC 17025–TestingThe results of the tests, calibrations and/ormeasurements included in this document are traceableto Australian/national standards.

Sample HistoryWhere samples are submitted/analysed over several days, the last date of extraction and analysis is reported.A recent review of our LIMS has resulted in the correction or clarification of some method identifications. Due to this,some of the method reference information on reports has changed. However, no substantive change has beenmade to our laboratory methods, and as such there is no change in the validity of current or previous results(regarding both quality and NATA accreditation).

If the date and time of sampling are not provided, the Laboratory will not be responsible for compromised resultsshould testing be performed outside the recommended holding time.

Description Testing Site Extracted Holding Time

Asbestos - LTM-ASB-8010 Sydney Oct 25, 2018 Indefinite

Asbestos - LTM-ASB-8010 Sydney Oct 25, 2018 Indefinite

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 3 of

Report Number: 624461-AFC

7

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 25, 2018 6:05 PMAddress: Level 1, 50 Margaret St Report #: 624461 Due: Oct 25, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

External Laboratory

No Sample ID Sample Date SamplingTime

Matrix LAB ID

1 DD126012 Oct 25, 2018 2:00PM Air S18-Oc31922 X

2 DD125989 Oct 25, 2018 2:02PM Air S18-Oc31923 X

3 DD126056 Oct 25, 2018 2:04PM Air S18-Oc31924 X

4 DD125991 Oct 25, 2018 2:06PM Air S18-Oc31925 X

5 DD125980 Oct 25, 2018 2:08PM Air S18-Oc31926 X

6 DD125983 Oct 25, 2018 2:10PM Air S18-Oc31927 X

7 DD126486 Oct 25, 2018 2:12PM Air S18-Oc31928 X

8 DD125993 Oct 25, 2018 2:14PM Air S18-Oc31929 X

9 DD126014 Oct 25, 2018 Air S18-Oc31930 X

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 4 of

Report Number: 624461-AFC

7

V2

ABN – 50 005 085 521e.mail : [email protected] : www.eurofins.com.au

Melbourne3-5 Kingston Town CloseOakleigh VIC 3166Phone : +61 3 8564 5000NATA # 1261Site # 1254 & 14271

SydneyUnit F3, Building F16 Mars RoadLane Cove West NSW 2066Phone : +61 2 9900 8400NATA # 1261 Site # 18217

Brisbane1/21 Smallwood PlaceMurarrie QLD 4172Phone : +61 7 3902 4600NATA # 1261 Site # 20794

Perth2/91 Leach HighwayKewdale WA 6105Phone : +61 8 9251 9600NATA # 1261Site # 23736

Company Name: JBS & G Australia (NSW) P/L Order No.: Received: Oct 25, 2018 6:05 PMAddress: Level 1, 50 Margaret St Report #: 624461 Due: Oct 25, 2018

Sydney Phone: 02 8245 0300 Priority: Same dayNSW 2000 Fax: Contact Name: Mark Hunter

Project Name: MAROUBRAProject ID: 55291

Eurofins | mgt Analytical Services Manager : Nibha Vaidya

Sample Detail

Asbestos (concentration of fibres in air)

Melbourne Laboratory - NATA Site # 1254 & 14271

Sydney Laboratory - NATA Site # 18217 X

Brisbane Laboratory - NATA Site # 20794

Perth Laboratory - NATA Site # 23736

Test Counts 9

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 5 of

Report Number: 624461-AFC

7

Internal Quality Control Review and Glossary

General1. QC data may be available on request.

2. All soil results are reported on a dry basis, unless otherwise stated.

3. Samples were analysed on an 'as received' basis.

4. This report replaces any interim results previously issued.

Holding TimesPlease refer to 'Sample Preservation and Container Guide' for holding times (QS3001).

For samples received on the last day of holding time, notification of testing requirements should have been received at least 6 hours prior to sample receipt deadlines as stated on the Sample

Receipt Advice.

If the Laboratory did not receive the information in the required timeframe, and regardless of any other integrity issues, suitably qualified results may still be reported.

Holding times apply from the date of sampling, therefore compliance to these may be outside the laboratory's control.

Units% w/w: weight for weight basis grams per kilogram

Filter loading: fibres/100 graticule areas

Reported Concentration: fibres/mL

Flowrate: L/min

TermsDry Sample is dried by heating prior to analysis

LOR Limit of Reporting

COC Chain of Custody

SRA Sample Receipt Advice

ISO International Standards Organisation

AS Australian Standards

WA DOH Reference document for the NEPM. Government of Western Australia, Guidelines for the Assessment, Remediation and Management of Asbestos-Contaminated

Sites in Western Australia (2009), including supporting document Recommended Procedures for Laboratory Analysis of Asbestos in Soil (2011)

NEPM National Environment Protection (Assessment of Site Contamination) Measure, 2013 (as amended)

ACM Asbestos Containing Materials. Asbestos contained within a non-asbestos matrix, typically presented in bonded and/or sound condition. For the purposes of the

NEPM, ACM is generally restricted to those materials that do not pass a 7mm x 7mm sieve.

AFAsbestos Fines. Asbestos containing materials, including friable, weathered and bonded materials, able to pass a 7mm x 7mm sieve. Considered under the NEPM as

equivalent to “non-bonded / friable”.

FA Fibrous Asbestos. Asbestos containing materials in a friable and/or severely weathered condition. For the purposes of the NEPM, FA is generally restricted to those

materials that do not pass a 7mm x 7mm sieve.

Friable Asbestos-containing materials of any size that may be broken or crumbled by hand pressure. For the purposes of the NEPM, this includes both AF and FA. It is

outside of the laboratory’s remit to assess degree of friability.

Trace Analysis Analytical procedure used to detect the presence of respirable fibres in the matrix.

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 6 of

Report Number: 624461-AFC

7

Comments

Volume Measurement : Mark Hunter, JBS & G Australia (NSW) P/L, has been trained by Eurofins | mgt and they conducted the sampling inaccordance with the National Occupational Health & Safety Commission - Guidance Note on The Membrane Filter Method For Estimating AirborneAsbestos Fibres 2nd Edition [NOHSC:3003(2005)]methodology. Sampling pumps used by JBS & G Australia (NSW) P/L were calibrated byEurofins | mgt and therefore volume measurements contained in this report are traceable back to Eurofins | mgt. Eurofins | mgt are responsible forall data contained in this report.

Sample IntegrityCustody Seals Intact (if used) N/A

Attempt to Chill was evident No

Sample correctly preserved Yes

Appropriate sample containers have been used Yes

Sample containers for volatile analysis received with minimal headspace Yes

Samples received within HoldingTime Yes

Some samples have been subcontracted Yes

Qualifier Codes/Comments

Code DescriptionN/A Not applicable

Asbestos Counter/Identifier:

Karthik Surisetty Senior Analyst-Asbestos (NSW)

Authorised by:

Sayeed Abu Senior Analyst-Asbestos (NSW)

Glenn Jackson

National Operations Manager

- Indicates Not Requested

* Indicates NATA accreditation does not cover the performance of this service

Measurement uncertainty of test data is available on request or please click here.Eurofins | mgt shall not be liable for loss, cost, damages or expenses incurred by the client, or any other person or company, resulting from the use of any information or interpretation given in this report. In no case shall Eurofins | mgt be liable for consequential damages including, but notlimited to, lost profits, damages for failure to meet deadlines and lost production arising from this report. This document shall not be reproduced except in full and relates only to the items tested. Unless indicated otherwise, the tests were performed on the samples as received.

Date Reported: Oct 25, 2018

Eurofins | mgt Unit F3, Building F, 16 Mars Road, Lane Cove West, NSW, Australia, 2066

ABN : 50 005 085 521 Telephone: +61 2 9900 8400

Page 7 of

Report Number: 624461-AFC

7

Final Report – this report replaces any previously issued Report